Sie sind auf Seite 1von 6

FRP VENTS

Fiberglass Reinforced Plastic Vents . . .


. . . No Exposed Metal Components PROTECTOSEAL ®

SERIES STYLE SIZES1


P8540 I H End-of-Line Pressure / Vacuum 12" - 12"
P18540 I H Pipe-Away Pressure / Vacuum 12" - 12"
P7800 I H End-of-Line Pressure 12" - 24"
P17800 I H Pipe-Away Pressure or Vacuum 12" - 12"
P6240 I H End-of-Line Vacuum 12" - 12"
P16240 I H Side Mounted Vacuum 12" - 12"
P53300 I Emergency Pressure Manhole Cover 16" - 24"
P4980 I Gauge Hatch 14" - 18"
P7300 I Overflow Valve 12" - 16"1
I MATERIAL CODE DESIGNATIONS:
“A” - Derakane® 470; “B” - Furan; “C” - Derakane® 411

OBJECTIVE Air-Cushioned Seating. Protectoseal patented and exclusive


Protectoseal FRP Vents are designed to provided pressure Protectoseal Air-Cushioned Seating for low evaporation
and / or vacuum relief in applications that control hazardous losses. FEP film diaphragms are standard, other materials can
vapors that would attack conventional metallic vents or com- be furnished on special request. The pallets have peripheral
ponents. Through the use of carefully chosen resins, (e.g. guiding and center stabilizing stem to ensure proper alignment
Derakane® 470, Derakane® 411 and Furan) a wide variety of and tight seating.
tank storage and product conservation applications are Numerous Sizes Available. All vents in the sizes shown
served. Such applications can be found in the chemical, petro- above mate with standard flanged 125# ANSI, API (20" or 24"
leum, petrochemical, pulp and paper, waste treatments, ultra only) or DIN PN 16 bolting specifications. Other drilling pat-
pure water and food & beverage industries. FRP eliminates terns are also available upon special request.
the need for exotic metal construction. PRO-FLOW III® Sizing and Selection Software. Use PRO-FLOW
TECHNIQUE III® to select the correct size unit for pressure and vacuum relief
Normal Conservation Breather Vents feature pressure and calculated in accordance with API 2000, ISO 28300, NFPA 30
vacuum pallets in the vent housing that retard intake of air and and OSHA 1910.106.
escape of vapors under normal conditions. Pallets open and
close to permit only that intake or outlet relief necessary to re- CONSTRUCTION
main within permissible working limits and avoid damage to Vents made from FRP resins are highly resistant to chemically
tanks, low pressure vessels and piping. In pipe-away models, hostile environments, yet extremely rugged and durable in
relieved vapors are piped away through a flanged connection. construction. Protectoseal’s “H” Series FRP models feature
no exposed metal parts and plastic external hardware for long
Emergency Relief Pressure Vents are designed to provide
service life in corrosive applications. All pallets are con-
emergency relief capacity beyond that furnished by the normal
structed of the same heavy-duty laminated resin as used in
operating vent on tanks, low pressure vessels and piping.
the vent body.
SPECIAL FEATURES Material Code “A” - Derakane® 470 Vinyl Ester Resin body,
Fast Inspection, Easy Maintenance. Rugged design and light cover and pallet; FEP diaphragms; Polyethylene screen; non-
weight provide for easy, convenient handling for installation, metallic external hardware; Derakane® 470 Resin coated steel
inspection,maintenance and cleaning. or uncoated lead weights, if required.
Maintains Accurate Pressure Settings. Factory tested and Material Code “B” - Furan body, cover and pallet; FEP di-
certified prior to shipment to assure every unit meets Protec- aphragms; Polyethylene screen; non-metallic external hard-
toseal’s stringent requirements. Leakage on vent pallets at ware; Furan coated steel or uncoated lead weights, if
standard settings is less than 1cu.ft. of standard air per hour required.
at 90% of the set pressure.
Material Code “C” - Derakane® 411 body, cover and pallet;
One-piece Construction. The one-piece construction of Pro- FEP diaphragms; Polyethylene screen; non-metallic external
tectoseal’s vent bodies eliminates the possibility of product
hardware; Derakane® 411 coated steel or uncoated lead
leakage through seams and ensures the integrity of the vent
weights, if required.
through an extended service life.
Available Options.
® Alternate diaphragm materials
Automatic Condensate Drainage. Self-draining body design

® “Double Veil” coated weights and Alloy C276 weights


keeps condensate away from seating surface. Vent is pro-
tected from freezing, binding and clogging.

www.protectoseal.com
Specifications FRP Vents
For Pressure / Vacuum Relief
Series P8540 I H - FRP End-of-Line Pressure / Vacuum Breather Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Ht. Width Length B.C. Dia. Dia. Holes


Cat. No. Size A B C D G E N
P8542 I H 12" 191/2” 12 3/8" 22" 14 3/4" 16" 13/4" 14
P8543 I H 13" 1
20 /2" 14" 22 7/8" 16" 17 1/2" 13/4" 14
P8544 I H 14" 3
25 /4" 1
16 /4" 30 3/8" 17 1/2" 19" 13/4" 18
P8546 I H 16" 29" 1
16 /4" 30 7/8" 19 1/2" 11" 17/8" 18
P8548 I H 18" 40 7/8" 21" 411/8" 113/4" 13 1/2" 17/8" 18
P8550 I H 10" 7
40 /8" 21" 411/8" 14 1/4" 16" 1" 12
P8552 I H 12" 5
43 /8" 3
24 /8" 46" 17" 19" 1" 12
I Material Code Designation: ”A” - Derakane® 470; “B” - Furan; “C” - Derakane® 411

Series P18540 I H - FRP Pipe-Away Pressure / Vacuum Breather Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Size Ht. Width Length B.C. B.C. Dia. Dia. Dia. Dia. Holes Holes
Cat. No.* Inlet x Outlet A B C F H D1 D2 G1 G2 E1 E2 N1 N2
P18542 I H2 12" x 2" 217/8" 10 3/4" 23 7/8" 10 3/8" 18" 14 3/4" 14 3/4" 16" 16" 13/4" 3/4" 14 14
P18542 I H3 12" x 3" 217/8" 10 3/4" 23 7/8" 11" 18" 14 3/4" 16" 16" 17 1/2" 13/4" 3/4" 14 14
P18543 I H3 13" x 3" 23 1/4" 10 3/4" 23 7/8" 113/8" 18" 16" 16" 17 1/2" 17 1/2" 13/4" 3/4" 14 14
P18543 I H4 13" x 4" 1
23 /4" 10 /4"3 7
23 /8" 12 1/8" 18" 16" 16" 17 1/2" 19" 13/4" 3/4" 14 18
P18544 I H4 14" x 4" 23 1/4" 15 3/8" 33 5/8" 15 3/8" 111/4" 17 1/2" 17 1/2" 19" 19" 13/4" 3/4" 18 18
P18544 I H6 14" x 6" 29 1/2" 15" 33 5/8" 15 3/4" 111/4" 17 1/2" 19 1/2" 19" 11" 13/4" 7/8" 18 18
P18546 I H6 16" x 6" 1
29 /2" 15" 1
33 /2" 1
16 /2" 111/4" 19 1/2" 19 1/2" 11" 11" 17/8" 7/8" 18 18
P18546 I H8 16" x 8" 1
29 /2" 15" 1
33 /2" 1
17 /8" 111/4" 19 1/2" 11 3/4" 11" 13 1/2" 17/8" 7/8" 18 18
P18548 I H10 18" x 10" 41" 1
20 /4" 1
44 /8" 1
23 /2" 14" 11 3/4" 14 1/4" 13 1/2" 16" 17/8" 1" 18 12
P18550 I H12 10" x 12" 41" 20 1/4" 44 1/8" 24 1/2" 14" 14 1/4" 17" 16" 19" 1" 1" 12 12
P18552 I H14 12" x 14" 45" 1
22 /2" 49" 3
27 /4" 151/4" 17" 18 3/4" 19" 21" 1" 11/8" 12 12
I Material Code Designation: ”A” - Derakane 470; “B” - Furan; “C” - Derakane® 411
®

Page 2

www.protectoseal.com
Specifications FRP Vents
For Pressure / Vacuum Relief
Series P6240 I H - FRP End-of-Line Vacuum Relief Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Ht. Width Length B.C. Dia. Dia. Holes


Cat. No.* Size A B C D G E N
P6242 I H 12" 13 3/4" 10 3/4" 211/4" 14 3/4" 16" 13/4" 14
P6243 I H 13" 15 5/8" 10 3/4" 211/4" 16" 17 1/2" 13/4" 14
P6244 I H 14" 1
19 /8" 15" 29 1/4" 16" 17 1/2" 13/4" 18
P6246 I H 16" 1
19 /8" 15" 29 1/4" 19 1/2" 11" 17/8" 18
P6248 I H 18" 1
26 /4" 20" 40" 11 3/4" 13 1/2" 17/8" 18
P6250 I H 10" 26 1/2" 20" 40" 14 1/4" 16" 1" 12
P6252 I H 12" 1
29 /4" 1
22 /2" 44 1/4" 17" 19" 1" 12
I Material Code Designation: ”A” - Derakane 470; “B” - Furan; “C” - Derakane® 411
®

Series P16240 I H - FRP Side Mount Vacuum Relief Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Valve Ht. Width Length Width B.C. Dia. Dia. Holes
Cat. No.* Size Size A B C H D G E N
P16240 I H2 12" 12" 14 1/4" 10 3/4" 13 3/8" 18" 14 3/4" 16" 13/4" 14
P16240 I H3 13" 13" 15 3/4" 10 3/4" 13 3/8" 18" 16” 17 1/2" 13/4" 14
P16240 I H4 14" 14" 3
18 /4" 3
15 /8" 18 3/4" 111/4" 17 1/2" 19" 13/4" 18
P16240 I H6 16" 16" 1
18 /8" 15" 18 3/4" 111/4" 19 1/2" 11" 17/8" 18
P16246 I H8 18" 16" 3
18 /4" 15" 18 3/4" 111/4" 11 3/4" 13 1/2" 17/8" 18
P16248 I H10 10" 18" 26 1/8" 20 1/4" 24 1/8" 14" 14 1/4" 16" 1" 12
P16250 I H12 12" 10" 3
26 /4" 1
20 /4" 24 1/4" 14" 17" 19" 1" 12
I Material Code Designation: ”A” - Derakane 470; “B” - Furan; “C” - Derakane® 411
®

Page 3

www.protectoseal.com
Specifications FRP Vents
For Pressure / Vacuum Relief
Series P7800 I H - FRP End-of-Line Pressure Relief (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Ht. Width B.C. Dia. Dia. Holes


Cat. No.* Size A B C D G E N
P7802 I H 12" 12 1/8" 12 3/8" 2" 14 3/4" 16" 15/8-11UNC 4 Studs
P7803 I H 13" 5
11 /8" 3
12 /8" 11/2" 16" 17 1/2" 13/4" 14
P7804 I H 14" 1
11 /4" 1
11 /2" 1 5/8" 17 1/2" 19" 13/4" 18
P7806 I H 16" 5
15 /8" 1
16 /4" 2" 19 1/2" 11" 17/8" 18
P7808 I H 18" 17 3/8" 16 1/4" 2" 11 3/4" 13 1/2" 17/8" 18
P7810 I H 10" 18 1/4" 21 1/2" 2" 14 1/4" 16" 1" 12
P7812 I H 12" 3
24 /4" 22 1/4" 3" 17" 19" 1" 12
P7816 I ASA 16" 19 3/4" 28" 11/2" 21 1/4" 23 1/2" 11/8" 16
P7820 I ASA 20" 21" 32" 15/8" 25" 27 1/2" 11/4" 20
P7820 I API 20" 21" 32" 15/8" 23 1/2" 26" 13/4" 16
P7824 I ASA 24" 5
24 /8" 40" 11/2" 29 1/2" 32" 1 3/8" 20
P7824 I API 24" 5
24 /8" 40" 11/2" 27 1/2" 30" 13/4" 20
I Material Code Designation: ”A” - Derakane® 470; “B” - Furan; “C” - Derakane® 411

Series P17800 I H - FRP Pipe-Away Pressure or Vacuum Breather Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange Size Ht. Width Length B.C. B.C. Dia. Dia. Dia. Dia. Holes Holes
Cat. No.* Inlet x Outlet A B C F H D1 D2 G1 G2 E1 E2 N1 N2
P17802 I H2 12" x 2" 16 3/4" 10 3/4" 13 3/8" 15 1/2" 18" 14 3/4" 14 3/4" 16" 16" 13/4" 13/4" 14 14
P17802 I H3 12" x 3" 3
16 /4" 10 /4"3 3
13 /8" 1
16 /8" 18" 14 3/4" 16" 16" 17 1/2" 13/4" 13/4" 14 14
P17803 I H3 13" x 3" 18 1/2" 10 3/4" 13 3/8" 16 1/2" 18" 16" 16" 17 1/2" 17 1/2" 13/4" 13/4" 14 14
P17803 I H4 13" x14" 1
18 /2" 3
10 /4" 7
13 /8" 1
17 /4" 18" 16" 17 1/2" 17 1/2" 19" 13/4" 13/4" 14 18
P17804 I H4 14" x14" 21 3/4" 15 3/8" 18 3/4" 17 1/2" 11 1/4" 17 1/2" 17 1/2" 19" 19" 13/4" 13/4" 18 18
P17804 I H6 14" x16" 21 3/4" 15" 18 7/8" 17 7/8" 11 1/4" 17 1/2" 19 1/2" 19" 11" 13/4" 17/8" 18 18
P17806 I H6 16" x16" 21 1/4" 15" 18 3/4" 18 5/8" 11 1/4" 19 1/2" 19 1/2" 11" 11" 17/8" 17/8" 18 18
P17806 I H8 16" x18" 1
21 /4" 15" 3
18 /4" 19 1/4" 11 1/4" 19 1/2" 11 3/4" 11" 13 1/2" 17/8" 17/8" 18 18
P17808 I H10 18" x 10" 29" 1
20 /4" 1
24 /8" 10 7/8" 14" 11 3/4" 14 1/4" 13 1/2" 16" 17/8" 1" 18 12
P17810 I H12 10" x 12" 1
29 /4" 20 /4"1 1
24 /4" 11" 14" 14 1/4" 17" 16" 19" 1" 1" 12 12
P17812 I H14 12" x 14" 30 3/4" 22 1/2" 26 1/2" 13 1/8" 151/4" 17" 18 3/4" 19" 21" 1" 11/8" 12 12
I Material Code Designation: ”A” - Derakane 470; “B” - Furan; “C” - Derakane® 411
®

Page 4

www.protectoseal.com
Specifications FRP Vents
For Pressure / Vacuum Relief
Series P53300 I - FRP Emergency Pressure Manhole Cover Vent (Dimensions shown are for reference only, contact factory for certified drawings)

Flange I.D. Ht. Width B.C. Dia. Holes


Cat. No.* Size K A B C E N
P53316 I ASA 16" 16" 6 3/4" 23 1/2" 211/4" 11/8" 16
P53318 I ASA 18" 16" 6 3/4" 25" 22 3/4" 11/4" 16
P53320 I ASA 20" 20" 6 3/4" 27 1/2" 25" 11/4" 20
P53320 I API 20" 20" 6 3/4" 26" 23 1/2" 13/4" 16
P53324 I ASA 24" 24" 6 3/4" 32" 29 1/2" 13/8" 20
P53324 I API 24" 24" 6 3/4" 30" 27 1/2" 13/4" 20
I Material Code Designation: ”A” - Derakane 470; “B” - Furan; C” - Derakane® 411
®

Series P4980 I - FRP Gauge Hatch (Dimensions shown are for reference only, contact factory for certified drawings)
Provide ready access to storage tank’s interior for inspection,
gauging and sampling. A gauge hatch is intended for use where the
fire protection afforded by a Protectoseal flame arrester is not
considered necessary,

Flange Ht. B.C. O.D. Dia. Holes


Cat. No.* Size A D G. E N
P4984 I 4" 4" 17 1/2" 19" 3/4" 8
P4986 I 6" 5" 1
19 /2" 11" 7/8" 8
P4988 I 8" 5 1/2" 11 3/4" 13 1/2" 7/8" 8
I Material Code Designation: ”A” - Derakane® 470; “B” - Furan;“C” - Derakane® 411

I - FRP Overflow Valve (Dimensions shown are for reference only, contact factory for certified drawings)
Series P7300I
For mounting on storage tank overflow pipes. This device eliminates
an open pipe connection into the vapor space of the tank. By
varying the weight on the lever arm handle, the opening point of the
overflow valve can be changed.

Flange Ht. B.C. O.D. Dia. Holes


Cat. No.* Size A D G. E N
P7302 I 2" 95/8" 43/4" 16" 3/4" 4
P7303 I 3" 5
9 /8" 6" 1
17 /2" 3/4" 4
P7304 I 4" 95/8" 71/2" 19" 3/4" 8
P7306 I 6" 95/8 91/2" 11" 7/8" 8
I Material Code Designation: ”A” - Derakane ® 470; “B” - Furan;“C” - Derakane® 411

Page 5

www.protectoseal.com
STANDARD PRESSURE AND/OR VACUUM SETTINGS (Consult factory for settings outside of STANDARD range.)

Page 6
MINIMUM SETTINGS MAXIMUM SETTINGS MINIMUM SETTINGS MAXIMUM SETTINGS
Flange Pressure Vacuum Pressure Vacuum Flange Pressure Vacuum Pressure Vacuum
Series Size oz./in.2 oz./in.2 oz./in.2 oz./in.2 Series Size oz./in.2 oz./in.2 oz./in.2 oz./in.2
I MATERIAL CODE DESIGNATIONS: FRP END-OF-LINE PRESSURE RELIEF VENT
“A” - Derakane® 470; “B” - Furan; “C” - Derakane® 411 P7802 I H 12" 1.00 N/A 48.00 N/A
FRP END-OF-LINE PRESSURE / VACUUM BREATHER VENT P7803 I H 13" 1.00 N/A 48.00 N/A
P8542 I H 12" 0.50 0.50 48.00 16.00 P7804 I H 14" 1.00 N/A 48.00 N/A
P8543 I H 13" 0.50 0.50 48.00 16.00 P7806 I H 16" 1.00 N/A 48.00 N/A
P8544 I H 14" 0.50 0.50 48.00 16.00 P7808 I H 18" 1.00 N/A 48.00 N/A

©2012 The Protectoseal Company


P8546 I H 16" 0.50 0.50 48.00 16.00 P7810 I H 10" 1.00 N/A 48.00 N/A
P8548 I H 18" 0.50 0.50 48.00 16.00 P7812 I H 12" 1.00 N/A 48.00 N/A
P8550 I H 10" 0.50 0.50 48.00 16.00 P7816 I ASA 16" 1.00 N/A 12.00 N/A
P8552 I H 12" 0.50 0.50 48.00 16.00 P7820 I ASA 20" 1.00 N/A 10.00 N/A
P7820 I API 20" 1.00 N/A 10.00 N/A
FRP END-OF-LINE PRESSURE / VACUUM BREATHER VENT P7824 I ASA 24" 1.00 N/A 10.00 N/A
P18542 I H2 12" x 2" 0.50 0.50 48.00 16.00 P7824 I API 24" 1.00 N/A 10.00 N/A
P18542 I H3 12" x 3" 0.50 0.50 48.00 16.00
P18543 I H3 13" x 3" 0.50 0.50 48.00 16.00 FRP PIPE-AWAY PRESSURE OR VACUUM RELIEF VENT
P18543 I H4 13" x 4" 0.50 0.50 48.00 16.00 P17802 I H2 12" x 2" 0.50 0.50 48.00 16.00

PROTECTOSEAL
Safety Without Compromise
®
P18544 I H4 14" x 4" 0.50 0.50 48.00 16.00 P17802 I H3 12" x 3" 0.50 0.50 48.00 16.00
P18546 I H6 16" x 6" 0.50 0.50 48.00 16.00 P17803 I H3 13" x 3" 0.50 0.50 48.00 16.00
Maximum Pressure & Vacuum Settings

P18546 I H8 16" x 8" 0.50 0.50 48.00 16.00 P17803 I H4 13" x 4" 0.50 0.50 48.00 16.00
P18548 I H10 18" x 10" 0.50 0.50 48.00 16.00 P17804 I H4 14" x4" 0.50 0.50 48.00 16.00
P18550 I H12 10" x 12" 0.50 0.50 48.00 16.00 P17804 I H6 14" x 6" 0.50 0.50 48.00 16.00
P18552 I H14 12" x 14" 0.50 0.50 48.00 16.00 P17806 I H6 16" x 6" 0.50 0.50 48.00 16.00
P17806 I H8 16" x 8" 0.50 0.50 48.00 16.00
FRP END-OF-LINE VACUUM RELIEF VENT P17808 I H10 18" x 10" 0.50 0.50 48.00 16.00
P6242 I H 12" N/A 0.50 N/A 16.00 P17810 I H12 10" x 12" 0.50 0.50 48.00 16.00
P6243 I H 13" N/A 0.50 N/A 16.00 P17812 I H14 12" x 14" 0.50 0.50 48.00 16.00
P6244 I H 14" N/A 0.50 N/A 16.00
P6246 I H 16" N/A 0.50 N/A 16.00 FRP EMERGENCY PRESSURE MANHOLE COVER VENT

P 630.595.0800 F 630.595.8059
P6248 I H 18" N/A 0.50 N/A 16.00 P53316 I ASA 16" 1 73 N/A 16.0 N/A
P6250 I H 10" N/A 0.50 N/A 16.00 P53318 I ASA 18" 1.73 N/A 16.0 N/A
P6252 I H 12" N/A 0.50 N/A 16.00 P53320 I ASA 20" 1.73 N/A 16.0 N/A

225 Foster Ave., Bensenville, IL 60106-1690


P53320 I API 20" 1.73 N/A 16.0 N/A

info@protectoseal.com www.protectoseal.com
FRP SIDE MOUNT VACUUM RELIEF VENT P53324 I ASA 24" 1.73 N/A 16.0 N/A
P16240 I H2 12" N/A 0.50 N/A 16.00 P53324 I API 24" 1.73 N/A 16.0 N/A
P16240 I H3 13" N/A 0.50 N/A 16.00
P16240 I H4 14" N/A 0.50 N/A 16.00 FRP GAUGE HATCH
P16240 I H6 16" N/A 0.50 N/A 16.00 P4984 I 14" 0.75 N/A N/A N/A
P16246 I H8 18" N/A 0.50 N/A 16.00 P4986 I 16" 0.75 N/A N/A N/A
P16248 I H10 10" N/A 0.50 N/A 16.00 P4988 I 18" 0.75 N/A N/A N/A
P16250 I H12 12" N/A 0.50 N/A 16.00 FRP OVERFLOW VALVE
P7302 I 12" 0.50 N/A 32.0 N/A
P7303 I 13" 0.50 N/A 16.0 N/A
For Pressure / Vacuum Relief
FRP Vents

V-FRP/7
P7304 I 14" 0.50 N/A 16.0 N/A
P7306 I 16" 0.50 N/A 16.0 N/A

Das könnte Ihnen auch gefallen