Electric Drive Unit
Low-impedance Solenoid-type Fuel Injector
Driver
The EDU is a programmable, universal driver for low-impedance solenoid-
type fuel injectors.
The technology
A&D's analog technology enables high-speed current measurement and high quality control.
https://www.aandd.jp/products/dsp/edu.html 1/6
11/3/2018 EDU (Electric Drive Unit) | DSP Platform | DSP | A&D
Valid during the whole period of Ph. The maximum-current value specified through an entire region. 4.00~
A High Current Upper Limit If current exceeds this threshold, an error [HC_ULE] is generated and SW status is changed to 25.00
"excitation current OFF." 22.00A
3.00~
Valid during the period of Ph-1 and 2.
B VH High Current Upper Value 24.00
If excitation current exceeds this value, VH excitation (S1) is turned OFF.
10.00A
2.00~
Valid during the period of Ph-1 and 2.
C VH High Current Lower Value 23.00
If excitation current drops below this value, VH excitation (S1) is turned ON.
7.00A
https://www.aandd.jp/products/dsp/edu.html 2/6
11/3/2018 EDU (Electric Drive Unit) | DSP Platform | DSP | A&D
D VB High Current Upper Value Valid during the period of Ph-1 and 2. 3.00~
If excitation current exceeds this value, VB excitation (S2) is turned OFF. 24.00
9.00A
2.00~
Valid during the period of Ph-1 and 2.
E High Current Lower Limit 23.00
If excitation current exceeds this value, VB excitation (S2) is turned ON.
8.00A
Valid during the period of Ph-2. Allowable minimum value of wave fluctuation during the retention
1.00~
period of a high current region.
F Low Current Upper Limit 24.00
If current drops below this threshold, an error [HC_LLE] is generated and SW status is changed to
6.00A
"excitation current OFF."
Valid during the period of Ph-4. If the maximum value of wave current fluctuation during the retention 4.00~
G VB Low Current Upper Value period of a low current region exceeds this threshold, an error [LC_ULE] is generated and SW status 25.00
is changed to "excitation current OFF." 22.00A
3.00~
Valid during the period of Ph-3 and 4.
H VB Low Current Lower Value 24.00
If excitation current exceeds this value, VB excitation (S2) is turned OFF.
4.00A
2.00~
Valid during the period of Ph-3 and 4.
I Low Current Lower Limit 23.00
If excitation current drops below this value, VB excitation (S2) is turned ON.
3.00A
Valid during the period of Ph-3 and 4. Allowable minimum value of wave fluctuation during the
1.00~
retention period of a low current region.
J OFF Current Upper Limit 10.00
If current drops below this threshold, an error [LC_LLE] is generated and SW status is changed to
2.00A
"excitation current OFF."
Valid during the period of Ph-0. Allowable-current value when setting excitation current to OFF. If 0.30~
K Rise Time Lower Limit current exceeds than this threshold, an error [operationality criterion_ULE] is generated and SW 1.00
status is changed to "excitation current OFF." 0.30A
Since the rate of current value change is too large if the rising period (Ph-1) of excitation current is 10~
T1 Rise Time Upper Limit shorter than this, an error [RT_LLE] is generated and SW status is changed to "excitation current 2,000
OFF." 10µS
Since the rate of a current value change is too small if the rising period (Ph-1) of excitation current is 10~
T2 High Current Interval Time longer than this, an error [RT_ULE] is generated and SW status is changed to "excitation current 2,000
OFF." 300µS
10~
T3 OFF Current Interval Time A period excited with high current. If it exceeds this time, the sequence shifts directly to Ph-3. 2,000
400µS
100~
During this time SW status changes to Excitation OFF.
T4 Injection Time Lower Limit 2,000
Excitation current becomes zero in this period. (Set it to take the value of an AD zero sampling.)
800µS
10~
T11 Injection Time Lower Limit Warning [IT_LLW] is generated if an injection instruction signal is less than this time. 2,000
100µS
10~
If an injection instruction signal exceeds this time, injection behavior is stopped directly and a
T12 Injection Time Upper Limit 2,000
warning [IT_ULW] is generated.
1,500µS
10~
If an injection indication signal time interval is less than this time, warning [IBM PCN II_LLW] is
T13 Injection Interval Lower Limit 2,000
generated.
100µS
100~
If an injection indication signal time interval exceeds this time, warning [IBM PCN II_ULW] is 13,000
T14 Injection Interval Upper Limit
generated. 1,000m
S
https://www.aandd.jp/products/dsp/edu.html 3/6
11/3/2018 EDU (Electric Drive Unit) | DSP Platform | DSP | A&D
Configuration
The crank angle signal is obtained from the engine.
Injection command signals (timing/duration) are generated from ECU or RPT.
Injection profile (current) is sent and controlled from the EDU.
Detailed injection control settings and commands required for R&D, which could not be obtained from a real ECU, can be realized with
the EDU.
EDU specifications
EDU 1x series EDU 2x series
Model Name
AD5452- AD5452-
AD5452-EDU11 AD5452-EDU21 AD5452-EDU22
EDU10 EDU20
Remote control
Standard
function
https://www.aandd.jp/products/dsp/edu.html 4/6
11/3/2018 EDU (Electric Drive Unit) | DSP Platform | DSP | A&D
Over-current fuse
Input Over-current fuse protected
protected
Injector Driver
System Current control
Measurement
0~45A
range
Measurement
±2% of F.S.
Current detection accuracy
AD resolution 10 bit
Sampling
1.25MHz
frequency
General specifications
CPU RENESAS SH-2 (SH7055F) processor
Size 250mm(W)x254mm(D)x73.5mm(H)