Sie sind auf Seite 1von 2

Type 4-131

VELOCITY VIBRATION TRANSDUCER


Made in the United States of America

DESCRIPTION
The 4-131 is a seismic mass type velocity transducer designed for measuring vertical vibrations at low frequencies and high
temps up to +700°F (+371°C) or +900°F (+482°C). A seismic mass magnet is suspended by springs and a coil attached to the
case. The output signal results from relative movement between the magnet and coil when the case vibrates. This air damped
system operates above its natural frequency so the output is proportional to velocity.

SPECIFICATIONS
Sensitivity:
@ +77°F (+25°C*), 100 Hz, 1 IPS (25.4 mm/sec) RMS into a 10,000 ohm resistive load

Model No. Sensitivity Connection Method


4-131-0001: 135 mV/ IPS (5.31 mV/mm/s) Std. 173960 / 169500-XXXX
4-131-0103: 150 mV/ IPS (5.91 mV/mm/s) Std. 173960 / 169500-XXXX
4131-0104: 145 mV/ IPS (5.71 mV/mm/s) Int. Cable, 20 ft., prepped leads
4131-0105: 145 mV/ IPS (5.71 mV/mm/s) Int. Cable, 6 ft., prepped leads
4-131-0106: 100 mV/ IPS (3.94 mV/mm/s) Std. 173960 / 169500-XXXX
4-131-0109: 135 mV/ IPS (5.31 mV/mm/s) Int. Cable, 15 ft., prepped leads
4-131-0116: 200 mV/ IPS (7.87 mV/mm/s) Std. 173960 / 169500-XXXX
4-131-0120: *135 mV/ IPS (5.31 mV/mm/s) Int. Cable, 21 ft., prepped leads
4-131-0123: *135 mV/ IPS (5.31 mV/mm/s) Std. 173960 / 365195-XXXX
4-131-0125: 135 mV/ IPS (5.31 mV/mm/s) Int. Cable, 21 ft., prepped leads
4-131-0128: *145 mV/ IPS (5.71 mV/mm/s) Int. Cable, 21 ft., prepped leads
4-131-0141: 150 mV/ IPS (5.91 mV/mm/s) Int. Cable, 35 ft., prepped leads
4-131-0148: 135 mV/ IPS (5.31 mV/mm/s) Int. Cable, 50 ft., prepped leads
* 900°F (+482°C) version

Frequency Range: 15 – 2000 Hz


Mounting Orientation: Sensitive axis is in longitudinal direction
Amplitude Range: 0.07 inch (1.78 mm) pk-pk maximum
Acceleration Range: 0.02 to 50 g peak
Sensitivity Shift w/ Position: 10% maximum
Temperature Range: -65°F to +700°F optional +900°F (-54°C to +371°C optional +482°C)
Thermal Coefficient of Sensitivity: 0.02%/°F from +77°F (0.04%/°C from +25°C)
Shock: 50 g
Damped Resonant Frequency: 15 Hz nominal
Excitation: Self-generating
Insulation Resistance: 100K ohm minimum
Polarity: Pin 1 is positive when case is moved away from base.
Weight: 5.8 oz (164 g) nominal
Accessories Included: Calibration Record
Optional Accessories: Cable w/connector (P/N 169500-XXXX)
Connector (P/N 173960)

INSTALLATION
Rigidly attach the transducer to the equipment under test using four screws and lock washers. Be sure to tighten the screws
securely. Connect one end of cable assembly to the transducer and the other end to the vibration monitoring device.

CAUTION: Never apply in excess of 45VDC across the terminals.

REPAIR
For further information contact:
Customer Service
CEC Vibration Products
746 Arrow Grand Circle
Covina, CA 91722

Phone: 626-938-0200
Fax: 626-938-0202

Document Number: 0610440-25-0001 (Rev: D)


SIGNAL SIGNAL
CONDITIONER CONDITIONER

SIG SIG

SIG COM

COIL COM COIL


SHIELD SHIELD

DIFFERENTIAL SINGLE ENDED


TRANSDUCER INPUT TRANSDUCER INPUT


12 o'clock
OK

BAD

270° 90°

SENSITIVE AXIS
OF 4-131
SENSOR

OK
180°
6 o'clock

Document Number: 0610440-25-0001 (Rev: D)