Sie sind auf Seite 1von 6

26230, 80107 NAMUR

3/2, 4/2 and 5/2 Directional control valves


Modular NAMUR design
Actuation: electromagnetic
Indirectly controlled spool valves
Port size: G 1/4
For single and double operated actuators

Standard manual override with detent

Compact design

High flow rate

Simple design of soft spool seal system

Maintenance-free

Easily interchangeable solenoid system

Exhaust air recirculation

The solenoids are ATEX approved


(see solenoids page 2)

Valves and solenoids are ATEX approved

Technical data
Medium:
Solenoid valve for filtered, lubricated *1) Ordering information
or non-lubricated air 3/2 directional control valve, connection G 1/4,
Operation: solenoid 24 V DC, protection class IP65
Solenoid, indirectly controlled Part No.: 8010777.3036.024.00
Connector: 0570275
Flow direction:
Fixed
Connections
Mounting position: See data sheet N/UK 7.7.002
Optional, preferably with solenoid on top
Nominal size:
6
Port size:
G 1/4
Electrical connection:
See solenoid table
Operating pressure:
2 to 8 bar
Temperature:
-10 ... 50°C 3/2 2 3
Please consult our technical service for use below +2°C. If installed
in the open protect all connections against the penetration of moisture! 12 10
Materials:
Housing: Aluminium
Pilot flange: Plastic 13
Seat seal: NBR (Perbunan)
5/2

*1) Oil recommendation: Shell Hydrol DO 32, Esso Febis (as of July 1992) or comparable 2 4 4 2
oils with DVI values < 8 (DIN 53521) and ISO viscosity class 32-46 (DIN 51519). 14 12 14 12

315 513

9/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.302.01
26230, 80107 NAMUR

General information
Symbol Type* Port size Actuation Nominal size Operating kv-value Weight Dimensions
1, 3 (5) 2 (4) pressure (bar) (Cv (US) ≈ kv x 1,2) (kg) Nr.
2 3 8010777 G 1/4 Flange Solenoid 6 2 ... 8 1,2 0,4 1
12 10 indirectly controlled

13

2 4
2623077 G 1/4 Flange Solenoid 6 2 ... 8 1,2 0,55 2
14 12 indirectly controlled
315

4 2
2623177 G 1/4 Flange 2 x Solenoid 6 2 ... 8 1,2 0,9 3
14 12 indirectly controlled
513

* When ordering please indicate solenoid, voltage and current type (frequency).
Port 3 not throttleable.

3/2- or 5/2 way function (Conversion Instruction see page 6)


Symbol Type* Port size Actuation Nominal size Operating kv-value Weight Dimensions
1, 3 (5) 2 (4) pressure (bar) (Cv (US) ≈ kv x 1,2) (kg) Nr.
2 3 2623079 G 1/4 Flange Solenoid 6 2 ... 8 1,2 0,4 4
12 10 indirectly controlled

13

2623179 G 1/4 Flange 2 x Solenoid 6 2 ... 8 1,2 0,9 5


2 4
14 12 indirectly controlled
315

* When ordering please indicate solenoid, voltage and current type (frequency).
Port 3 not throttleable.

Solenoid actuators
Type Power consumption Rated current at Protection class Temperatur e Weight Dimensions Circuit
24 V DC 230 V AC 24 V DC 230 V AC Fluid max. Ambience diagram
(W) (VA) (mA) (mA) (°C) (kg) No. No.
3050 *2) 1,7 5,6/4,3 – IP 65 -40 ... +50 0,06 6 1
with connector
DIN EN 175301-803
Form B *6)
3036 *2) 1,6 3,5 30 – IP 65 -40 ... +50 0,1 7 1
with connector
DIN EN 175301-803
Form A *6)
3062 *3) 2,7 – 115 – Cat. II2G, EEx m II T5 -20 ... +50 0,3 8 1
3 m cable

3063 *3) – 2,1 – 9 Cat. II2G, EEx m II T5 -20 ... +50 0,3 8 8
3 m Kabel

3071 2,7 – 115 – IP 66 -10 ... +50 0,3 9 8


Connector M12x1
DIN EN 60947-5-2 Anh. D

Standard voltages 24 V DC, 230 V AC. Other voltages on request.


Design acc. to VDE 0580, EN 50014/50028. 100% duty cycle.

*1) Valves can only be operated with DC solenoids


*2) Required connector, see page 3
*3) Certificate of Conformity PTB No. PTB 03 ATEX 2015 X
*6) Connector is not indicated in delivery

N/UK 5.4.302.02 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
9/05
26230, 80107 NAMUR

Accessories
Silencer Connectors Flange plate Yoke

0014600 (G1/4) *1) 0570275 Form A 0612790 NAMUR sigle connection plate 0540593
0680003 Form B 0612791 NAMUR rip use in combination with 0612790 ( Alu)
*1) For indoors use

Basic dimensions for valves


Œ
36
1

2
143,5
G1/4

3
ø 5,5

2
24

12

M5

1
12

4
24

35

5 3

ø15,5 5
ø19,5 7 30 5
32
55

 36
1

2
ø 19,5

126
ø 15,5
G1/4

1
2
24

M5
12

3
12

4
23

ø 5,5

ø15,5 3 5
ø19,5 7 30 5
32 1 Solenoid 90° turnable
55
2 Manual override

9/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.302.03
26230, 80107 NAMUR

Ž 36
1

2
G1/4

3
2
24

12

223
1
12 4

M5
24

ø 5,5
5
3

111,5
2

ø15,5 5
ø19,5 7 30 5
32
55


36
1

14

1 2 1
0 0
143,5

G 1/4

3
ø 5,5

4
24
ø 13

1
12
ø 19,5

2
M5

24

5
35
35

32 5
55 37 5

1 Solenoid 90° turnable

2 Manual override

N/UK 5.4.302.04 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
9/05
26230, 80107 NAMUR

 36
1

14
2
1 1
0 0

G 1/4
3
3

ø 5,5
4

24
ø 13
223

12
2
ø 19,5

M5

24
35
5

35
0 0
1 1

12

32
55 1 Solenoid 90° turnable

2 Manual override

Dimensions for solenoid operators

‘ ’
29 36
29,5
29,5

11 15

65 12 72 12
30
22

Ø9 Ø9

“ ”
29
38,5 10
M12x1
29,5

29,5

4
1 3
2

14,5
29,5
22

~ 56

9/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.302.05
26230, 80107 NAMUR

Circuit diagrams

Œ “

NAMUR hole pattern


32
M5 4

24
2 3 2 Port 2 (A)

3 3 Coding stud threaded

4 M5 (10 deep)

5 Port 3 (R)
5

Conversion instructions of 5/2 into 3/2 way function

5/2 way function (original mode of supply) 3/2 way function

5/2 3/2

7 6 7 6

3/2 resp. 5/2 way function can be achieved just 6 arrow


by swapping enclosed adaptor plates. Make sure 7 Marker
Marker and Arrow do match as shown on above
drawing. Original mode of supply: 5/2 function.

Warning
These products are intended for use in industrial compressed air sys- systems and to provide adequate safeguards to prevent personal
tems only. Do not use these products where pressures and tempera- injury or damage to equipment in the event of such failure.
tures can exceed those listed under ‘Technical Data’.
System designers must provide a warning to end users in the
Before using these products with fluids other than those specified, for
system instructional manual if protection against a failure mode
non-industrial applications, life-support systems, or other applications
cannot be adequately provided.
not within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid power System designers and end users are cautioned to review specific
systems can fail in various modes. The system designer is warned to warnings found in instruction sheets packed and shipped with these
consider the failure modes of all component parts used in fluid power products where applicable.

N/UK 5.4.302.06 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
9/05