Structural Pro™ Laminated Glass Load Resistance Report

Project Details Report Details


Project name enquiry System of Units SI
Project location dxb Date 7/16/2017
Requested by comsultant prepared by shafeeq

Rectangular Dimensions Laminate Load Data


Unsupported Length 1400 mm Uniform load 1.12 kPa
Supported Length 1050 mm Line Load 0.00 kN/m
Point Load 0.00 N
Glazing Information Self Weight 0.00 kPa
Simply Supported Edges 1 Load Duration 3.00 sec
Glazing Angle 90 ° Temperature 20 °C (68 °F)
Overall Nominal thickness 19.5 mm Max Allowable Stress 73.0 MPa
Laminate mass/area 47.2 kg/m² Max Allowable Deflection 21.0 mm
Laminate mass 69.4 kg
Stress and Deflection Data**
Laminate Construction Laminate Stress 21.8 MPa
Glass Outboard Fully Tempered 10.0 mm (3/8 in.) Laminate Deflection 18.8 mm
Interlayer 1 Saflex® R 1.52 mm (0.060 in.) *Effective thickness models used:
Interlayer 2 Stress: 17.4 mm; Deflection: 16.8 mm
Interlayer 3
Interlayer 4 Interlayer Data**
Glass Inboard Fully Tempered 8.0 mm (5/16 in.) Shear Modulus (G) 14.0 MPa
Young's Modulus (E) 42.0 MPa
Poisson's Ratio 0.50

Results ** 3.00 sec @ 20 °C (68 °F)

Design Configuration meets or exceeds user defined deflection limits


Design Configuration meets or exceeds user defined stress limits

Disclaimer
This software can be used to calculate load resistance of specified glass types exposed to uniform lateral and combined point and uniform loads of short or long duration subject to the following conditions:

1. The glass is free of edge and surface damage and has been properly glazed in the opening in conformance with the manufacturer's recommendations;
2. Glass was designed using the proper procedure for the application including but not limited to edge support, temperature, load type and duration.
3. The stiffness of members supporting any glass edge shall be sufficient that under design load, edge deflections shall not exceed L/175, where L denotes that length of the supported edge.
4. The non-factored load values for laminated glass are representative of test data and calculations performed for polyvinyl butyral interlayer at temperatures between 0ºC (32ºF) of 80ºC (176ºF).
Although the information and/or recommendations as may be set forth herein (hereafter "Information") are presented in good faith and believed to be correct at the date hereof, Eastman Chemical Company and its
affiliates (hereinafter "Eastman") make no representations or warranties as to the completeness or accuracy thereof. Information is supplied upon the condition that the persons receiving same will make their own
determination as to its suitability for their purposes prior to use. In no event will Eastman be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product
to which Information refers. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and Eastman makes no
representation or warranty, express or implied, that the use thereof will not infringe any patent. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.

© 2014 Eastman Chemical Company, Kingsport, Tennessee, U.S.A. All rights reserved. Saflex®, Vanceva® and Structural Pro™ are trademarks of
Eastman Chemical Company. As used herein, ® denotes registered trademark status in the U.S. only.

730 Worcester Street, Springfield, MA 01151


413.730.3413 | glazing@eastman.com (E) Structural Pro™ V2.1 051115

Das könnte Ihnen auch gefallen