Sie sind auf Seite 1von 2

Product Data

HEMPADUR XP 87550
87550: BASE 87559: CURING AGENT 98550

Description: HEMPADUR XP 87550 is an amine-adduct cured epoxy coating. It is hard, impact and abrasion
resistant with excellent temperature resistance and cathodic disbondment resistance. The product can
be applied by standard heavy duty airless spray equipment.
Recommended use: As a self-primed, high build coating primarily for protection of exterior of steel pipes in severely
corrosive environment, including burried pipelines in wet grounds.
For new constructions as well as a field-applied renovation and repair coating.
Can be applied to lines while in service at temperatures up to 90°C/194°F.
Service temperature: Maximum, dry exposure only: 130°C/266°F.
Wet (as external coating on hot pipes only): 110°C/230°F.
Availability: Subject to special agreement.
PHYSICAL CONSTANTS:
Shade nos/Colours: 59700 / Red.
Finish: glossy
Volume solids, %: 90 ± 1
Theoretical spreading rate: 1.5 m2/l [60.2 sq.ft./US gallon] - 600 micron/24 mils
Flash point: 14 °C [57.2 °F]
Specific gravity: 1.6 kg/litre [13 lbs/US gallon]
Dry to touch: 7 hour(s) 20°C/68°F
Fully cured: 7 day(s) 20°C/68°F
VOC content: 193 g/l [1.6 lbs/US gallon]
- The physical constants stated are nominal data according to the HEMPEL Group's approved formulas.

APPLICATION DETAILS:
Version; mixed product: 87550
Mixing ratio: BASE 87559: CURING AGENT 98550
4 : 1 By volume
Application method: Airless spray
Thinner (max.vol.): 08450 (2%)
Pot life: 1.5 hour(s) 20°C/68°F
Nozzle orifice: 0.023 - 0.025 "
Nozzle pressure: 250 [3625 psi]
(Airless spray data are indicative and subject to adjustment)
Cleaning of tools: HEMPEL'S TOOL CLEANER 99610
Indicated film thickness, dry: 600 micron [24 mils]
Indicated film thickness, wet: 675 micron [27 mils]
Recoat interval, min: According to specification.
Recoat interval, max: According to specification.
Safety: Handle with care. Before and during use, observe all safety labels on packaging and paint containers,
consult HEMPEL Safety Data Sheets and follow all local or national safety regulations.

Date of issue: January 2012 Page: 1/2 Product Data Sheet


-
HEMPADUR XP 87550
SURFACE PREPARATION: Abrasive blasting to Sa 2½, (ISO 8501-1:1988), with a surface profile equivalent to Rugotest No. 3 BN
10b, Keane-Tator Comparator 3.0 G/S or ISO Comparator, rough MEDIUM (G).
Oil and grease must be removed by suitable detergent, salts and other contaminants by (high pressure)
fresh water hosing prior to blasting.
APPLICATION CONDITIONS: The surface must be completely clean and dry at the time of application and its temperature must be
above the dew point to avoid condensation.
Minimum steel temperature: 10°C/50°F. Maximum steel temperature approximately: 90°C/194°F. The
temperature of the paint itself should be above: 10°C/50°F, preferably 20-30°C/68-86°F.
In confined spaces provide adequate ventilation during application and drying. Maximum relative
humidity: 85%.
PRECEDING COAT None.
SUBSEQUENT COAT: None, or as per specification.
REMARKS: Due to a high concentration of conductive barrier pigments in the product, high voltage holiday
detection is not applicable, use low voltage wet sponge pinhole detection at 9 Volt.

Recoating note: The indicated over coating interval will normally only apply in connection with touch-up of areas with too
low dry film thickness.
If the maximum over coating interval is exceeded, roughening of the surface is necessary to ensure
intercoat adhesion.
Nota: HEMPADUR XP 87550 For professional use only.
ISSUED BY: HEMPEL A/S 8755059700

This Product Data Sheet supersedes those previously issued.


For explanations, definitions and scope, see “Explanatory Notes” available on www.hempel.com. Data, specifications, directions and recommendations given in this data sheet represent only test results
or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions of any intended use of the Products herein
must be determined exclusively by the Buyer and/or User.
The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed in writing.
The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said GENERAL CONDITIONS for all
results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise. Product data are subject to change without notice
and become void five years from the date of issue.

Date of issue: January 2012 Page: 2/2 Product Data Sheet


-

Das könnte Ihnen auch gefallen