Performance and reliability. At Honeywell Sensing and All humidity sensors are configured with integrated circuitry
Productivity Solutions (S&PS), each sensor is designed to provide to provide on-chip signal conditioning offered on all products.
enhanced stability, reliability and sensitivity. Potential applications are as diverse as heating, ventilation
and air conditioning equipment (HVAC), refrigeration, office
Honeywell HumidIcon™ Digital Humidity/Temperature sensors automation, and medical equipment.
offer a range of accuracies from ±1.7 %RH to ±4.5 %RH, wide
operating temperature ranges and low hysteresis.

FEATURES
hUMIDITY sENSORS resistance • Ultra-small package and wireless-compatible applications to
Honeywell HumidIcon™ • Industry-leading relative humidity enhance energy savings and prolong
Digital Humidity/Temperature accuracy • Tape and reel • Wide system battery life. The sensor goes
Sensors operating temperature ranges into sleep mode when not taking a
HIH6000 Series, HIH6100 Series, • Optional one or two %RH level alarm measurement within the application,
HIH7000 Series, HIH8000 Series outputs • Multi-function ASIC • RoHS and consuming only 1 μA versus 650 μA in full
HIH9000 Series WEEE compliant, halogen-free operation in a battery operated system;
helps maximize battery life, reduces power
Honeywell HumidIcon™ Digital Humidity/ Benefits: Industry-leading long term supply size, and reduces the application’s
Temperature Sensors are digital stability minimizes system performance overall weight. High 14-bit humidity
output-type relative humidity (RH) and issues, helps support system uptime sensor resolution and 14-bit temperature
temperature sensors combined in the by eliminating the need to service or sensor resolution within the application
same package. They are available in the replace the sensor during its application help the user’s system detect the smallest
following accuracies: life, and eliminates the need to regularly relative humidity or temperature change.
±1.7 %RH (HIH9000 Series) recalibrate the sensor in the application, True, temperature-compensated digital
±2.0 %RH (HIH8000 Series) which can be inconvenient and costly. I2C or SPI output typically allows the
±3.0 %RH (HIH7000 Series) Thermoset-polymer capacitive sensing customer to remove the components
±4.0 %RH (HIH6100 Series) element’s multilayer construction provides associated with signal conditioning from
±4.5 %RH (HIH6000 Series) resistance to most application hazards the PCB to free up space and reduce
such as condensation, dust, dirt, oil, and costs associated with those components
Features: Industry-leading long term common environmental chemicals, which (e.g., acquisition, inventory, assembly),
stability (1.2 %RH over five years) help provide industry leading reliability. often eliminates problems that could
• Industry-leading reliability (MTTF Delivers the lowest total cost solution due occur from having multiple signal
9,312,507 HR) • Lowest total cost solution to the sensor’s industry-leading combined conditioning components across the PCB,
• Combined humidity and temperature humidity/temperature sensor. Allows as well as simplifies integration to the
sensor • Energy efficient • High resolution the RH measurement to be temperature microprocessor, eliminating the need for
• True, temperature-compensated compensated and provides a second, customer-implemented, complex signal
digital I2C or SPI output • SOIC-8 SMD standalone temperature sensor output conditioning. Ultra-small size allows for
(Surface Mount Device) and SIP 4 Pin which allows the user to purchase one flexibility of use within the application,
housing styles • Available with or without sensor instead of two. Can operate down occupies less space on the PCB, and
hydrophobic filter and condensation- to 2.3 Vdc, which allows use in low energy typically simplifies placement on crowded
continued on page 5
Humidity Sensors Line Guide

Highly viable humidity


sensing solutions. Humidity Sensors
And every Honeywell S&PS
Honeywell HumidIcon™ Honeywell HumidIcon™
sensor contains something HIH6000 Series HIH6100 Series
no other supplier can offer:
Description digital output-type relative humidity (RH) and temperature sensors combined in the same package
Honeywell engineering and
expertise. This means an Humidity accuracy ±4.5 %RH typ. ±4.0 %RH typ.
unparalleled feature and Temperature accuracy (BFSL) ±0.5 °C ±0.5 °C
benefit set: A capacitive Operating temperature range -40 °C to 100 °C [-40 °F to 212 °F] -25 °C to 85 °C [-13 °F to 185 °F]
sensing die set in thermoset Hysteresis - -
polymers interacts with Output I2C or SPI I2C or SPI
platinum electrodes. Laser- Package type SIP 4 Pin or SOIC-8 SMD SIP 4 Pin or SOIC-8 SMD
trimmed sensors designed
Response time 6 s typ. in 20 l/min airflow 6 s typ. in 20 l/min airflow
to offer stable, low-drift
Long-term stability ±1.2 %RH for five years ±1.2 %RH for five years
performance and enhanced
accuracy with calibration. Operating humidity range 0 %RH to 100 %RH 0 %RH to 100 %RH
Absorption-based humidity Compensated humidity range 20 %RH to 80 %RH 10 %RH to 90 %RH
sensors provide both Moisture filter yes (some listings) yes (some listings)
temperature and %RH. Voltage supply 3.3 Vdc typ. 3.3 Vdc typ.
Packages are chemically
resistant and operate in
wide temperature ranges
— performing in most harsh
environments.
Humidity Sensors
Most importantly, Honeywell HIH-5030/5031 Series HIH-4000 Series
S&PS’s legendary engineering
expertise, proven product covered, filtered or unfiltered integrated
dependability, global reach Description integrated circuit
circuit
and support and superior Output analog voltage analog voltage
technical support deliver the SIP (2,54 mm [0.100 in] or
most critical advantage of all: Package type surface mount
1,27 mm [0.050 in] lead pitch)
reliable quality products for a Response time 5 s typ. 1/e in slow moving air 5 s typ. 1/e in slow moving air
lower total cost of ownership.
1.2 %RH for five years; 1.2 %RH for five years;
Long-term stability
0.25 %RH each year 0.25 %RH each year
Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F]
Operating humidity range 0 %RH to 100 %RH 0 %RH to 100 %RH
Moisture/dust filter yes (some listings) no
Cover/case yes no
Calibration and data printout no yes (some listings)
Accuracy ±3 %RH ±3.5 %RH
Voltage supply 2.7 Vdc to 5.5 Vdc 4 Vdc to 5.8 Vdc

2 sensing.honeywell.com
Humidity Sensors
Honeywell HumidIcon™ Honeywell HumidIcon™ Honeywell HumidIcon™
HIH7000 Series HIH8000 Series HIH9000 Series
Description digital output-type relative humidity (RH) and temperature sensors combined in the same package
Humidity accuracy ±3.0 %RH typ. ±2.0 %RH typ. ±1.7 %RH typ.
Temperature accuracy (BFSL) ±0.5 °C ±0.5 °C ±0.3 °C
Operating temperature range -40 °C to 100 °C [-40 °F to 212 °F] -40 °C to 125 °C [-40 °F to 257 °F] -40 °C to 125 °C [-40 °F to 257 °F]
Hysteresis - - ±1.0 %RH
Output I2C or SPI I2C or SPI I2C or SPI
Package type SIP 4 Pin or SOIC-8 SMD SIP 4 Pin or SOIC-8 SMD SIP 4 Pin or SOIC-8 SMD
Response time 6 s typ. 20 l/min airflow 6 s typ. 20 l/min airflow 30 s max. 1/e slow moving air
Long-term stability ±1.2 %RH for five years ±1.2 %RH for five years ±1.2 %RH for five years
Operating humidity range 0 %RH to 100 %RH 0 %RH to 100 %RH 0 %RH to 100 %RH
Compensated humidity range 20 %RH to 80 %RH 10 %RH to 90 %RH 10 %RH to 90 %RH
Moisture filter yes (some listings) yes (some listings) yes (some listings)
Voltage supply 3.3 Vdc typ. 3.3 Vdc typ. 3.3 Vdc typ.

Humidity Sensors
HHIH-4010/4020/4021 Series HIH-4030/4031 Series

Description covered or uncovered, filtered or unfiltered


covered, filtered or unfiltered integrated circuit
integrated circuit
Output analog voltage analog voltage
SIP (2,54 mm [0.100 in] or
Package type surface mount
1,27 mm [0.050 in] lead pitch)
Response time 5 s typ. 1/e in slow moving air 5 s typ. 1/e in slow moving air
1.2 %RH for five years; 1.2 %RH for five years;
Long-term stability
0.25 %RH each year 0.25 %RH each year
Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F]
Operating humidity range 0 %RH to 100 %RH 0 %RH to 100 %RH
Moisture/dust filter yes (some listings) yes (some listings)
Cover/case yes (some listings) yes
Calibration and data printout yes (some listings) yes (some listings)
Accuracy ±3.5 %RH ±3.5 %RH
Voltage supply 4 Vdc to 5.8 Vdc 4 Vdc to 5.8 Vdc

sensing.honeywell.com 3
Humidity Sensors
HIH-4602-A, C HIH-4602-L, L-CP

Description monolithic IC with integral thermistor or precision RTD integrated circuit


analog voltage (for humidity),
Output analog voltage
resistance (for temperature)
Package type TO-5 can slotted TO-5 can
Response time 50 s typ. 1/e in slow moving air 30 s typ. 1/e in slow moving air
1.2 %RH for five years; 1.2 %RH for five years;
Long-term stability
0.25 %RH each year 0.25 %RH each year
Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F]
Operating humidity range 0 %RH to 100 %RH 0 %RH to 100 %RH
Moisture/dust filter yes (some listings) no
Cover/case yes yes
Calibration and data printout yes (some listings) yes (some listings)
Accuracy ±3.5 %RH ±3.5 %RH
Voltage supply 4 Vdc to 5.8 Vdc 4 Vdc to 5.8 Vdc

Humidity Sensors Used in


Wall Mount Transducers SCT Series
(Asia-Pacific Region Only)
Description humidity and temperature wall mount transducer using Honeywell HumidIcon™ humidity/temperature sensor
Humidity measurement range 0 % RH to 100 %RH non-condensation
±4 %RH (25 °C [77 °F], 10 %RH to 90 %RH)
Humidity accuracy
±5 %RH (5 °C to 50 °C [41 °F to 122 °F], 10 %RH to 90 %RH)
-5 °C to 55 °C [13 °F to 131 °F]
Temperature measurement range 0 °C to 70 °C [32 °F to 158 °F]
-25 °C to 60 °C [-13 °F to 140 °F]
Temperature accuracy ±0.5 °C, ±0.3 °C, ±0.2 °C, or ±1 °C (depending on type of internal sensor used)
Long term drift ±0.05 %RH typ. and ±1.2 %RH max. at 50 %RH for 5 years stability
-20 °C to 70 °C [-4 °F to 158 °F] (units with LDC display)
Operating temperature range
-25 °C to 85 °C [-13 °F to 185 °F] (units without LDC display)
24 Vdc ±10%, 50 mA max. (units with 4 mA to 20 mA output)
Voltage supply
18 Vdc to 40 Vdc, 15 mA max. or 24 Vac ±15%, 50/60 Hz, 50 mA max (units with 0 V to 10 V output)

4 sensing.honeywell.com
PCBs or in small devices; industry HIH-4000 Series. Benefits: Instrumentation-quality sensing
standard design simplifies design-in. Features: Voltage output • Near linear performance in a competitively priced,
hydrophobic filter allows for use in many voltage output vs %RH • Laser-trimmed solderable surface mount device.
condensing environments. Tape and reel • Accurate, fast response • Molded Multilayer construction designed to
allows for use in high volume, automated thermoset plastic housing • Chemically provide enhanced resistance to wetting,
pick-and-place manufacturing, eliminating resistant • Accuracy of ±3.5 %RH dust, dirt, oils, and common environmental
lead misalignment to the PCB and helping • Voltage supply of 4 Vdc to 5.8 Vdc chemicals. Low current draw often ideal in
the customer to reduce manufacturing most low drain, battery operated systems.
Benefits: Instrumentation-quality RH
costs. Wide operating temperature Tight sensor interchangeability reduces
sensing performance in a competitively
ranges allow for use in many applications. or eliminates OEM production calibration
priced, solderable SIP. Multilayer
Optional one or two %RH level alarm costs. Tape and reel for high volume
construction designed to provide excellent
outputs provide the ability to monitor applications (optional). Factory calibration
resistance to wetting, dust, dirt, oils and
whether the RH level has exceeded or data designed to provide individually
common environmental chemicals. Laser
fallen below pre-determined and critical matched downstream electronics and
trimmed for stable, low drift performance
levels within the application. Multi- accuracy. Available covered, filtered/
(optional). Factory calibration data
function ASIC delivers flexibility within unfiltered for application flexibility in high
provides individually matched downstream
the application by lowering or eliminating volume OEM condensing environments
electronics and accuracy.
the risk and cost of OEM calibration. such as HVAC, refrigeration, medical,
May be used in such potential industrial office automation, and telecommunications
HIH-4010/4020/4021 Series.
applications as HVAC/R, air compressors, equipment.
Features: Voltage output • Near linear
weather stations, telecom cabinets,
voltage output vs %RH • Laser-trimmed
incubators/microenvironments and in such HIH-4602 A, C Series.
• Accurate, fast response • Molded
potential medical apps such as respiratory Features: Humidity and temperature
thermoset plastic housing • Designed to
therapy, incubators/microenvironments. sensing in one package • Near linear
be chemically resistant • Accuracy of
voltage output vs %RH • Laser-trimmed
±3.5 %RH • Voltage supply of 4 Vdc to 5.8
HIH-5030/5031 Series. • Accurate, fast response • Designed to
Vdc
Features: Surface mount package be chemically resistant • Built-in static
• Voltage output • Operates at 2.7 Vdc Benefits: Instrumentation-quality RH protection • Accuracy of ±3.5 %RH
to 5.5 Vdc • Laser-trimmed • Accurate, sensing performance in a competitively • Voltage supply of 4 Vdc to 5.8 Vdc
fast response • Molded thermoset plastic priced, solderable packages. Multilayer • Stable, low drift performance • TO-5 can
housing • Designed to be chemically construction provides enhanced
Benefits: Combine both relative humidity
resistant • Tape and reel • Accuracy of resistance to wetting, dust, dirt, oils and
and temperature sensing for measuring
±3 %RH common environmental chemicals. Laser
dew point and other absolute moisture
trimmed for stable, low drift performance.
Benefits: Instrumentation-quality sensing terms. Can-type housing designed
Factory calibration data designed to
performance in a competitively priced, to provide quick response while still
provide individually matched downstream
solderable surface mount device. maintaining robustness of enclosed
electronics and accuracy (available on all
Multilayer construction designed to component. Factory calibration data
voltage output models). Available covered/
provide enhanced resistance to wetting, designed to provide individually matched
uncovered and filtered/unfiltered for
dust, dirt, oils, and common environmental downstream electronics and accuracy,
application flexibility in high volume OEM
chemicals. Low current draw often ideal standard. Laser trimmed for stable, low
condensing environments such as HVAC,
in most low drain, battery operated drift performance in potential applications
refrigeration, medical, office automation,
systems. Tight sensor interchangeability such as HVAC, refrigeration, medical,
and telecommunications equipment.
reduces or eliminates OEM production office automation, telecommunications
calibration costs. Tape and reel for high and meterology equipment.
HIH-4030/4031 Series.
volume applications (optional). Available
Features: Surface mount package
covered, filtered/unfiltered for application HIH-4602-L, L-CP Series.
• Voltage output • Near linear voltage
flexibility in high volume OEM condensing Features: Voltage output • Near linear
output vs %RH • Laser-trimmed
environments such as battery-powered voltage output vs %RH • Laser-trimmed
• Accurate, fast response • Molded
systems, air compressors, HVAC, • Accurate, fast response • Designed to
thermoset plastic housing • Designed to
refrigeration, medical, office automation, be chemically resistant • Built-in static
be chemically resistant • Tape and reel
telecommunications equipment, and protection • Accuracy of ±3.5 %RH
• Accuracy of ±3.5 %RH • Voltage supply
weather meteorology equipment. • Voltage supply of 4 Vdc to 5.8 Vdc
of 4 Vdc to 5.8 Vdc
• Stable, low drift performance • Slotted
TO-5 can

sensing.honeywell.com 5
Benefits: Slotted can design allows for While we provide application assistance
quick response while still maintaining personally, through our literature and
robustness of enclosed components. the Honeywell web site, it is up to the
Factory calibration data designed to customer to determine the suitability of the
provide individually matched downstream product in the application.
electronics and accuracy, optional.
Laser trimmed for stable, low drift Specifications may change without notice.
performance in potential applications The information we supply is believed to
such as refrigeration, drying, meterology be accurate and reliable as of this printing.
equipment, battery-powered systems, and However, we assume no responsibility for
OEM (Original Equipment Manufacturer) its use.
assemblies.
For more information about Sensing and
HUMIDITY SENSORS USED IN Control products, visit sensing.honeywell.
WALL MOUNT TRANSDUCERS com or call +1-815-235-6847
(Asia-Pacific region only) Email inquiries to info.sc@honeywell.com

SCT Series
Warranty. Honeywell warrants goods of
Features: Utilize Honeywell HumidIcon™
its manufacture as being free of defective
humidity/temperature sensors • Optional
materials and faulty workmanship.
LCD display shows ambient temperature
Honeywell’s standard product warranty
with relative humidity or dew point • True
applies unless agreed to otherwise by
temperature-compensated humidity
Honeywell in writing; please refer to your
element • Enhanced accuracy • Long-
order acknowledgement or consult your
term stability • Enhanced reliability
local sales office for specific warranty
• Standard humidity output • Cost-
details. If warranted goods are returned to
effective • Choice of silver or gold
Honeywell during the period of coverage,
cover trim • Full 0 %RH to 100 %RH
Honeywell will repair or replace, at its
measurement range
option, without charge those items it finds
defective. The foregoing is buyer’s sole
Benefits: Accurately and reliably senses
remedy and is in lieu of all warranties,
humidity and temperature in the area to
expressed or implied, including those
enhance user comfort. Enables customer
of merchantability and fitness for a
to potentially reduce/eliminate transmitter
particular purpose. In no event shall
recalibration cost. Supports and optimizes
Honeywell be liable for consequential,
system accuracy and uptime. Enhanced
special, or indirect damages.
stability over next best alternatives.
Humidity sensor element’s multilayer
construction provides resistance to most
application hazards such as dust, dirt,
condensation, oils and common
environmental chemicals. Potential
industrial applications include climate
monitoring and control for residential
and office buildings, production and
manufacturing plants, storerooms,
equipment cabinets, and testing
environments.