Sie sind auf Seite 1von 1

Call 888-766-7834

Press 1 and ask for


installation assistance

Perimeter Lights Supplemental Installation Instructions


Installation - Tools Needed
 MC Cutter & Wire Strippers  Small Flat Tip Screwdriver
 Lineman Pliers  Phillips Tip Screwdriver
 1 1/4” Hole Saw Bit

1. Install perimeter lights power supply. Place 2. Attach light mounting brackets. Remove
power supply box on canopy (near the center). Drill 1 plastic/tape covering lights. From clear acrylic side
1/4” diameter hole through canopy where box will be of light panel, insert supplied machine screw thru
mounted. Install plastic bushing in hole. Mount power hole. Slide nut into channel mounting bracket and
supply box and gang box to canopy. DO NOT supply align with screw. Partially tighten screw allowing for
power to supply box at this time. For more detailed adjustment. Ensure frosted edge of light is facing
installation instructions, see instructions in light kit down and mounting bracket will slide straight down
box. Installer on top of canopy to return to inside cab. onto ceiling frame. Repeat for remaining mounting
brackets.
Follow the specific model ceiling installation
instructions to assemble ceiling frame and for any
additional lighting.

3. Attach perimeter lights. Align end of longest 4. Make final power connection. Connect lights to
light fixture with longest ceiling edge. Attach lights to terminal block in transformer. Red wires to posi-
ceiling frame by pushing down on mounting clips tive, black wires to negative. No more than two (2)
until clips lock into place on frame. Ensure bottom lights per post. See the wiring instructions for more
edge of light is flush with ceiling face. Tighten screw information. Make sure power is off before connect-
holding light to mounting bracket. Tighten remaining ing building power to switch. The switch will have
mounting bracket screws. Repeat to attach remaining two (2) black wires, and one (1) green (ground) wire.
light fixtures. Connect ground wire from the switch to ground wire
Follow the specific model ceiling installation from transformer and building ground. Connect white
instructions to attach the ceiling to the canopy. wire from transformer to neutral wire from building.
Connect one black wire on switch to black wire con-
nected to transformer. Connect the other black wire
on switch to common (hot) wire from building power.
Carefully fold wires into gang box, screw switch into
place, and screw on cover plate.
Perimeter Lights Supplemental Installation Instructions 1 of 1 2/2017