Current Limiting Relay

Part No DA1859/60

Technical Data
Simple systems need not be certified but if certification is required, a dual channel shunt diode safety barrier
can be specified on the low-current side of the relay.

Relay
1
2
3
4
5 Fuses
B E 6
2A 100mA
7
8

C = Height of box with cover on


View inside enclosure without cover

Switched circuits 2

Solenoid normally de-energised 4

Solenoid common 5

Solenoid normally energised 6


2A 100mA
Negative supply (-ve) 7

Positive supply (+ve) 8

Current Limiting Relay Circuit diagram showing termination block identities

Dimensions
The Fluid Transfer Current Limiting Relay dimensions are as follows:
Part No Item A B C D E
DA1859 12V Current Limiting Relay 135 73 73 95 50
DA1860 24V Current Limiting Relay 135 73 73 95 50

Dimensions in (mm)

Spares
The following replacement Fuse are available on request:
Part No Fuses Relay
2A 100mA
DA1859 151-486 799-920 25D02C14B
DA1860 151-486 799-920 25D02C20B

FTi’s policy of continuous improvement means we reserve the right to alter designs and specifications without notice.
The descriptions, illustrations and product references in the datasheet are for information purposes only and are not binding.

T: +44 (0)1453 833 381 F: +44 (0)1453 833 529 E: sales@fluid-transfer.co.uk W: www.fluid-transfer.co.uk
Current Limiting Relay
Part No DA1859/60

Applications
Current limiting relay reducing current to
intrinsically safe levels for protection
against sparking should a wiring fault occur.
Provides safe operation of interlocks in
Deadman and other interlock systems.
SIzes
Versions available:
• 12Vdc
• 24Vdc
Features
• Overload protection of:
- Switching current (limited to 2A)
- Relay coil (limited to 100mA)
• Resilient mounting enclosure
Options
• Dual channel shunt diode safety barrier
(if certification is required)

Specification
The Fluid Transfer Current Limiting Relay provides for the safe
operation of Interlock Systems, Deadman Systems and in some
cases automatic Recovery Tank Emptying Control Systems.

These very simple, reliable relays limit the system current to


intrinsically safe levels such that no sparking can occur if a wiring
fault develops. The relays must only be used in "simple" systems
where no energy storing potential is possible, preferably using
hermetically sealed proximity switches.

The relay is fully protected against overload by two fuses, one


limiting the switching current to 2A and the other protecting the
relay coil to 100mA. All switched inductive loads are protected
against damaging "back – EMF’s" by "quench" diodes.

T: +44 (0)1453 833 381 F: +44 (0)1453 833 529 E: sales@fluid-transfer.co.uk W: www.fluid-transfer.co.uk A 2.5