For NG, LPG, Air, Nitrogen Gas & All Inert Gas

GAS METER
Diaphragm
GAS METER

Head Office
4B -15L, Panwol Industrial Complex 731-7, Won Si-Dong, Ansan City, Kyunggi-Do, Korea
TEL. 82 -31- 490-0561~ 0563 FAX. 82 - 31 - 490- 0564
Seoul Office
No.27,6th Floor, 3-Dong, 123 Electronic Center, 76 - 41, Ko -Chuk 1Dong, Kuro -Ku,
Seoul Korea
TEL. 82 - 2-2165 -2721 ~ 4 FAX. 82 -2-3775 -3175
Web Site
www.meters.co.kr / e-mail kumhotec@meters.co.kr

The specifications described here may be subjected to change without previous notice.
DIAPHRAGM
GAS METER C ontents
4~5 KG - 2 (G 1.6)
6~7 KG - 3 (G 1.6) & KG - 3S (G1.6)
KumHo gas meter has been supplied throughout the world for many decades.
8~9 KG - 4 (G 2.5)
The quality and durability is proven among customers in Russia / CIS, 10 ~ 11 KG - 6 (G 4)
South America, South East Asia and Middle East. 12 ~ 13 G6 / G10 ~ G25 / G40 ~ G100

14 ~ 15 PREPAYMENT
www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

SPECIFICATION
DIAPHRAGM Normal Working Pressur Max.1000 mm H2O(10kaPa)

GAS METER W
C
D2

D1
Maximum Flowrate
Minimum Flowrate
Cyclic Volume
2.5m3/h
16L/h
0.4L/rev
Register Capacity 9,999m3
Minimum Graduation 0.2L
Net Weight /With Accessries 1.2/1.47kg

H
Hight (H) 197 mm
Width (W) 128 mm
Dimension Center(C) 100 mm
Depth (D1) 44 mm
Depth (D2) 110 mm
Inlet & Outlet Connection Size 15 mm (1/2 inch)

CONSTRUCTION MATERIAL

Valve travel system consists of horizontal crank Aluminum - diecasting body is proven to be solid structure.
shaft and rotary valve. Valve made of graphite - teflon phenol resin
Use of anti-freezing and round synthetic minimizes friction and increases wear-resistance
diaphragm rubber ensure long life time. and anti - freezing.
Separation of measuring chamber and index Highly wear - resistant bearings and sturdy
eliminates leakage of gas, even though index transmission parts ensure a long trouble - free life.
cover glass is broken. Especially rotarying parts are sealed tightly with
All components are assembled by screws. anti-freezing grease.
So repairing is easy.

PERFORMANCE CURVE

KG-2(G1.6)

FEATURES
Most Suitable small gas meter LP gas cylinder.
(LPG, NG, air, Nitrogen gas, Inert gas also available) CONNECTION TUBE & NUT
Maximum flowrate 2.5 /h is one of the most important features
NUT(mm) TUBE(mm)
in consideration of meter size. Model
A B C D E a b c d e
Sufficient aging time of components ensures long working life.
30 15mm
KG-2(G1.6) 21 25 3.0 16 14 18 50 44
1 Sthrood’s/ PT 1/2”
inch

4 KumHo Metertech, Inc. KumHo Metertech, Inc. 5


www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

SPECIFICATION
DIAPHRAGM
KG-3S(G1.6) Category KG-3S(G1.6) KG-3(G1.6)

GAS METER
W D2
C D1 Normal Working Pressure Max.1000 mm H2O Max.1000 mm H2O
Maximum Flowrate 3.1 m3 / h 3.1 m3 / h
Minimum Flowrate 16 L / h 16 L / h
Cyclic Volume 0.7 L / rev 0.7 L / rev

H
Register Capacity 9,999 m3 9,999 m3
Minimum Graduation 0.2 L 0.2 L
KG-3(G1.6) Net Weight /With Accessories 1.6 / 1.88 kg 1.6 / 1.88 kg
W D2
C D1 Hight (H) 209 mm 214 mm
Width (W) 146 mm 164 mm
Dimension Center(C) 100 mm 130 mm
Depth (D1) 51 mm 51 mm

H
Depth (D2) 130 mm 130 mm
Inlet & Outlet Connection Size 15 mm (1 / 2 inch) 20 mm (3 / 4 inch)

CONSTRUCTION MATERIAL

Valve travel system consists of horizontal crank Aluminum - diecasting body is proven to be solid structure.
shaft and rotary valve. Valve made of graphite - teflon phenol resin
Use of anti-freezing and round synthetic diaphragm minimizes friction and increases wear - resistance
rubber ensure long life time. and anti - freezing.
Separation of measuring chamber and index Highly wear - resistant bearings and sturdy
eliminates leakage of gas, even though transmission parts ensure a long trouble - free life.
index cover glass is broken. Especially rotarying parts are sealed tightly with
All components are assembled by screws. anti-freezing grease.
So repairing is easy.

PERFORMANCE CURVE

KG-3S(G1.6) & KG-3(G1.6)

FEATURES
For its small size, maximum flowrate is 3.1m3 / h CONNECTION TUBE & NUT
High sensitivity enables to measure even smaller flame of
pilot burner exactly. NUT(mm) TUBE(mm)
Model
Sufficient aging time of components ensures long working life. A B C D E a b c d e
15mm
KG-3S(G1.6) 30 21 25 3.0 16 14 18 50 44
18 Thread’s/inch PT 1/2
20 mm
KG-3(G1.6) 37 28 M34 1.5 3.0 16 20 15 55 48
PT 3/4

6 KumHo Metertech, Inc. KumHo Metertech, Inc. 7


www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

SPECIFICATION
DIAPHRAGM Normal Working Pressur Max.1000 mm H2O

GAS METER W

C
D2

D1
Maximum Flowrate
Minimum Flowrate
Cyclic Volume
4.0 m3 / h
25 L / h
1.0 L / rev
Register Capacity 99,999 m3
Minimum Graduation 0.2 L
Net Weight /With Accessries 2.0 / 2.3 kg
Hight (H) 230 mm

H
Width (W) 165 mm
Dimension Center(C) 130 mm
Depth (D1) 54 mm
Depth (D2) 135 mm
Inlet & Outlet Connection Size 20 mm (3 / 4 inch)

CONSTRUCTION MATERIAL

Valve travel system consists of horizontal crank Aluminum - diecasting body is proven to be solid structure.
shaft and rotary valve. Valve made of graphite - teflon phenol resin
Use of anti-freezing and round synthetic diaphragm minimizes friction and increases wear - resistance
rubber ensure long life time. and anti - freezing.
Separation of measuring chamber and index Highly wear - resistant bearings and sturdy
eliminates leakage of gas, even though index transmission parts ensure a long trouble - free life.
cover glass is broken. Especially rotarying parts are sealed tightly with
All components are assembled by screws. anti - freezing grease.
So repairing is easy.

PERFORMANCE CURVE

KG-4(G 2.5)

FEATURES
For its small size,maximum flowrate is 4.0m3 / h CONNECTION TUBE & NUT
High sensitivity enables to measure even smaller flame of
pilot burner exactly. NUT(mm) TUBE(mm)
Model
Sufficient aging time of components ensures long working life. A B C D E a b c d e

Enlarged index for convenient reading. 37


20mm
KG-4(G2.5) 28 M34 1.5 3.0 16 20 15 55 PT 3/4 48

8 KumHo Metertech, Inc. KumHo Metertech, Inc. 9


www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

SPECIFICATION
DIAPHRAGM Normal Working Pressure Max.0.5 bar

GAS METER W
C
D
E
Maximum Flowrate
Minimum Flowrate
Cyclic Volume
6.0m3 / h
40 L
1.5 L
Register Capacity 9,999m3
Minimum Graduation 0.2 L
Weight 3.7 kg

H
Hight (H) 278 mm
Width (W) 198 mm
Dimension
Depth (D) 154 mm
Center(C) 130 mm
Inlet & Outlet Connection Size 20 mm (3 / 4 inch)

CONSTRUCTION MATERIAL

Valve travel sysrem of KG-6(G4) consists of Aluminum - diecasting body is proven to be


vertical crank shaft and straight valve. solid structure.
Use of anti-freezing and round synthetic diaphtragm Valve made of graphite - teflon phenol resin minimizes
rubber ensures long life time. friction and increases wear - resistance and anti-freezing.
Separation structure of measuring chamber and Highly wear - resistant bearings and sturdy transmission
index eliminates leakage of gas, even though index parts ensure a long trouble - free life.
cover glass is broken. Especially, crank shaft is sealed tightly with anti - freezing
All components are assembled by screws. grease.
So reparing is easy.

PERFORMANCE CURVE

KG-6(G 4)

FEATURES
Max, flowrate per hour for KG-6(G4) is 6.0m3/H.
High sensitivity enables to measure even smaller flame of CONNECTION TUBE & NUT
pilot burner exactly.
Distinguished weather-proof, for body is made of aluminium diecasting. NUT(mm) TUBE(mm)
Model
Simple in setting and pipe laying. A B C D E a b c d e
Employment of instrumental ettor matching device offers a uniform 20mm
instrumental error curve from a small flowrate to a large flowrate and KG-6(G4) 37 28 M34 1.5 3.0 16 20 15 55 PT 3/4 48
the fall in the maximum flowrate is slight.
Space of standing drain is large, not the late motion and no motion by drain.

10 KumHo Metertech, Inc. KumHo Metertech, Inc. 11


www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

DIMENSIONS
DIAPHRAGM

GAS METER

VARIOUS
Connections to

VARIOUS
customer
requirements. Connections to
customer
requirements.

314mm

584mm
TECHNICAL DATA

Connection Flowrate Working Cycle Pulse Dimension Weight Remark


(M3/H) Pressure Volume Value
DN(MM) Qmin. Qmax. Bar dm3 m3 A B C D kg
G6 25 0.04 10 0.5 2.0 0.01 250(152.4) 192 81 4
G10 40 0.1 16 0.5 5.88 0.1 390 280(152.4/250) 260 116 10
G16 40 0.16 25 0.5 10 0.1 406 280(250) 300 135 16.5
G25 50 0.25 40 0.5 20 0.1 476 335(280/400) 390 180 26.5
G40 80 0.4 65 0.5 30 0.1 615 430(335/500) 390 180 43.5
G65 80 0.65 100 0.5 60 0.1 750 500(430) 525 255 78
G100 100 1.0 160 0.5 75 0.1 750 500(430) 530 255 84

G40 ~ G100(65m3/ h ~ 160m3/ h) PERFORMANCE CURVE


G10 ~ G25(16m / h ~ 40m / h)
3 3
G6 G25 G100

G6(10m3/ h)

FEATURES G10 G40


Low pressure loss
Wide range of measurements by volumetric type.
Valve's movement by radial method
Excellent Gastightness
Designed by ISO 900l
Pulse Hansmitter available of AMR (Automatic Meter-reading System) G16 G65

High fireproofing and Gasthgitness by materials of body made of Terne

12 KumHo Metertech, Inc. KumHo Metertech, Inc. 13


www.meters.co.kr
For NG, LPG, Air, Nitrogen Gas & All Inert Gas

SPECICATION
DIAPHRAGM

GAS METER
Normal Working Pressure Max.1000 mm H2O
Maximum Flowrate 3.1m3 / h
Minimum Flowrate 16L / h
Cyclic Volume 0.7L / rev
Register Capacity 9,999 m3
Minimum Graduation 0.2 L

OPERATION

Request Recharge Request Recharge

Recharge Approval Recharge

Gas utlity Data Base Station for card issuing Customers

Card Life Cycle Benefit for IC Card system

Customer Utility
PREPAYMENT Issuing IC Card Purchasing Card
IC Meter

System
Mal-functioned card Insert it to Gas Meter Utility
Definition Features - Demand expectation
Error O.K
- Saving maintenance cost
Prepayment Gas Meter is a brand-new type of Safety against gas leakage due to including - Providing customized service
Gas Meter. You can insert IC Card into Gas Meter. function of simple Micom Gas Meter, Card recharge Alarm for shortage Customer
IC Card is rechargeable. As a result, we can which cuts gas off within 0.3s
- Paying according to actual consumption
get rid of reading,billing,unpayment or billing Prevention from billing unpaid by Prepayment - Keeping security from meter readers
overdue. By reducing cost in this way, utilities can System. - Reading meters during absence
make a big profit to supply gas to customer in No need to send meter reder.
cheaper price. Gas shut-off Out of balance System
Possible to supply gas in cheaper price. - Constructing system aimed at future usages
TOU - Constructing customized service system

14 KumHo Metertech, Inc. KumHo Metertech, Inc. 15