STEEL FLOOR

PLATE 3/16"
2-1/4"

5/8"
24"

3"

B
1/8" 5/8" BAR
S.W. (CONT.)

A 4 TACK WELDS A 3"x3"x1/4"


EQUALLY ANGLE (CONT.)
SPACED
TACK
WELDS

1/2" x 3"
STEEL ANCHOR
12" O.C.
C&G
2'

3"

DETAIL "I"
B

LIP OF GUTTER

PLAN

DETAIL "I"
STEEL WEAKENED
FLOOR PLATE 24" PLANE JOINT
2%

6"
TYPICAL

2%
BACK OF
SIDEWALK
6"
S.W.
4"

6"

8" 12" 12" 8" 6" TYPE I OR TYPE II


19-1/2"
FLOWLINE AGGREGATE BASE
OF GUTTER

SECTION A-A SECTION B-B

NOTES:

1. IF WIDTH OF PLATE IS GREATER THAN 24", A SPECIAL DESIGN IS REQUIRED.

2. ALL EXPOSED METAL PARTS SHALL BE GALVANIZED AND ALL GALVANIZING


DAMAGED BY FABRICATION OR INSTALLATION SHALL RECEIVE TWO COATS
OF ALUMINUM PAINT (GALVONOX OR EQUAL).

AGENCY APPROVED B C H L M N

SPECIFICATION REFERENCE UNIFORM STANDARD DRAWINGS


CLARK COUNTY AREA
302 BASE AGGREGATES
501 CONCRETE
710 STRUCTURAL STEEL SIDEWALK DRAIN

DATE DWG. NO. 236