Beruflich Dokumente
Kultur Dokumente
ENTERPRISE 3PL
RF GUIDE
90 South Cascade Avenue, Suite 1200
Colorado Springs, CO 80903 August 2015
www.accellos.com 4.0.1*
Copyright © HighJump
All rights reserved
This manual is reserved for licensed users of AccellosOne Enterprise 3PL and e-Vista. If you are not a
licensed user of AccellosOne Enterprise 3PL and e-Vista, no part of this publication may be reproduced,
stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, recording or
otherwise, without the prior written consent of HighJump.
The information in this manual is furnished for informational use only, is subject to change without notice and
should not be construed as a commitment of HighJump. HighJump assumes no responsibility or liability for
any errors or inaccuracies that may appear in this manual.
TABLE OF CONTENTS
INTRODUCTION 1
Before You Begin ............................................................................................................................. 2
AccellosOne 3PL Documentation Set ............................................................................................ 2
RF GUIDE 4.0.1* i
O U T B O U N D S ET U P P R O G R A M S 9 3
Overview ......................................................................................................................................... 94
Customer Codes (CUST) ............................................................................................................... 94
Customer / Consignee Document Setup (CCDU)........................................................................ 96
Item Hazardous Material Violation (IHZV) .................................................................................... 97
Outbound Pallet Building .............................................................................................................. 98
Task Profile (REGI)....................................................................................................................... 101
Item Consignee Configuration (ICOC) ....................................................................................... 106
Outbound Process Configuration (CCCC)................................................................................. 107
Document Messages Block ............................................................................................. 110
Warehouse Customer Consignee OPID Rule (WCCO) ..............................................................110
Customer/Consignee Outbound Rules (CCOR) .........................................................................111
I N B O U N D P R O C ES S I N G 1 3 7
Overview of Put-Away ................................................................................................................. 138
Understanding Inbound Flows in RF ......................................................................................... 139
Overview of the Unique Identifier (UI) ........................................................................................ 139
Unloading Product in RFCH........................................................................................................ 140
Overriding the System-Assigned Location ...................................................................... 155
Entering Trailer and Pallet Information ............................................................................ 156
Performing Queries ......................................................................................................... 160
Entering Partial U-Type Receipt Lines ............................................................................ 161
ii 4.0.1* RF GUIDE
Printing Labels ................................................................................................................. 162
Understanding Variances in RFCH ................................................................................. 163
Processing Variances ...................................................................................................... 164
Entering Process Values ................................................................................................. 166
Validating Process Values ............................................................................................... 168
Creating a New Line ........................................................................................................ 169
Receiving Product Under an Alternate Item Code........................................................... 170
Receiving Product on Automatic Hold ............................................................................. 172
Receiving Product with a Variable Product Breakdown .................................................. 173
Receiving Mixed Product ................................................................................................. 173
Looking Up Temperature and Trailer Information in LORE ............................................. 175
Looking Up Remarks and Messages in RFCH ................................................................ 176
Entering Temperature and Trailer Information in RFTT............................................................ 177
Putting Away Product in RFPU................................................................................................... 178
Overriding the System-Assigned Location ...................................................................... 184
Entering Variances .......................................................................................................... 185
Putting Away Product Under an Alternate Item Code ..................................................... 187
Putting Away in a Pick Line Location............................................................................... 188
Entering Process Values in RFIPS ............................................................................................. 188
Deleting a Receipt Line in RFDL................................................................................................. 190
iv 4.0.1* RF GUIDE
Creating a New OPID ...................................................................................................... 286
Performing Outbound Audits in RFOA ...................................................................................... 287
Assigning Orders to Loads in SELO .......................................................................................... 290
RF GUIDE 4.0.1* v
Assigning Check Digits to Locations in LOCA ................................................................. 346
Setting Up Your Reason Codes in REAS ........................................................................ 348
Activating Your Voice Terminals in MHEC ...................................................................... 349
Picking Orders in RFPV............................................................................................................... 351
Assigning RF Operators to Orders in RFOT.............................................................................. 354
Assigning RF Operators to Orders and Order Lines ....................................................... 354
Assigning RF Operators to Loads ................................................................................... 357
Assigning RF Operators to Pick Methods........................................................................ 359
Removing an Operator Assignment ................................................................................ 359
Clearing Work Assignments in CTPA......................................................................................... 360
CARTONIZATION 363
Overview ....................................................................................................................................... 364
Cartonization Tab (MRFP) ........................................................................................................... 364
Carton Size Setup (CTSZ)............................................................................................................ 366
Outbound Process Configuration (CCCC)................................................................................. 368
Carton Size Code Block .................................................................................................. 370
Packing Station Code (PKST) ..................................................................................................... 371
Item Cartonization Profile Code (ICNP)...................................................................................... 373
Consignees (CONS) ..................................................................................................................... 374
Performing Manual Cartonization in RFSC................................................................................ 375
Working With Closed Cartons ......................................................................................... 379
Performing System-Driven Cartonization in RFPK................................................................... 380
Performing Second Level Cartonization.................................................................................... 387
Performing Manual Packing in EPSD......................................................................................... 388
Tracking Your Progress in EPSD .................................................................................... 393
Deleting a Carton’s Contents........................................................................................... 394
Working With Unclosed Cartons...................................................................................... 394
Looking Up Cartons in LOCN ..................................................................................................... 395
Deleting Closed Cartons in DCAR.............................................................................................. 397
vi 4.0.1* RF GUIDE
RF Operator (RFOP)..................................................................................................................... 408
Locations (LOCA) ........................................................................................................................ 409
Warehouse Shift Setup (WASH).................................................................................................. 409
Looking Up Equipment Tracking Data ....................................................................................... 410
INDEX 421
RF GUIDE 4.0.1* 1
INTRODUCTION
Before You Begin
This manual contains the majority of core RF programs that are part of AccellosOne 3PL. The following core
RF programs are not included:
RFCY (RF Cycle Count) — see Cycle Counting Guide
RFPH (RF Entering Physical Inventory Tickets) — see Physical Inventory Guide
RFPL/RFPR (Replenishment) see Allocation and Wave Manager
OLOP (Outbound Loading Process) see Operations 2 Guide
Allocation and Wave allocation setup, inbound and outbound allocation, pick lines and replenishment,
Manager reserve logic and Wave Manager
Billing and Invoicing billing setup, cash posting system, maximum and minimum charges, renewal stor-
Guide age, extra charges, invoicing, accessorial bill later and bill immediate charges, rollup
invoicing and billing/invoicing reports
Core Documents core documents, maintain programs for core documents, document overlays, cus-
Guide tomizing the accessorial invoice, Oracle Reports, BarTender Label Printing
Cycle Counting Guide setup and operational programs for cycle counting as well as the cycle counting
reports
Guide to Active- logging on to and off from ActiveDesktop, the alerts system, e-Filing, selecting your
Desktop/A13PL company, working with menus and programs, basic queries, Signature Capture
Operations 1 Guide receiving and confirming product, printing receiving documents, shipping R-type and
P-type orders, printing order documents, entering inventory adjustments, relocating
product, entering hold adjustments
Operations 2 Guide appointment planner, back orders, batch picking, manual packing, customer relation-
ship management, EDI, faxing and auto-printing, item substitution, kitting, labor track-
ing, Operational Board, pallet control, inventory attributes, item process values,
outbound load building, quick response labels
Physical Inventory setup and operational programs for physical inventory as well as the physical inven-
Guide tory reports
RF Guide setup programs for RF (Radio Frequency), RF receiving, RF picking, entering pro-
cess values in RF, voice-activated picking, order assignment system, equipment
tracking, interleaving, cartonization, outbound pallet building
2 4.0.1* RF GUIDE
INTRODUCTION
AccellosOne 3PL Documentation Set
Setup Guide mandatory setup programs including warehouses and locations, isolators, inventory
level profiles, customers, charge codes, item profiles, items, carriers, shippers, con-
signees
System Administra- operator and menu setup, company and program access, operator restrictions, purg-
tion Guide ing and archiving, conversions, special verify programs, translation manager
RF GUIDE 4.0.1* 3
INTRODUCTION
AccellosOne 3PL Documentation Set
4 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR) ......................................................................... 6
Bar Code Profile Code (BAPR) ........................................................................ 11
RF Profile (MRFP).............................................................................................. 15
Item RF Profile (MIRP) ...................................................................................... 77
Depositor Workflow Profile (DIFP) .................................................................. 79
RF Operator (RFOP) .......................................................................................... 79
Extra Charge Setup for RF ............................................................................... 81
Warehouse Zones (WHZO) ............................................................................... 84
RF Supervisors.................................................................................................. 92
RF GUIDE 4.0.1* 5
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR)
In this program, you define your scan parameters for bar coded labels. SCPR allows you to break up a bar
code into its component parts and capture a separate value for each part. For example, the first four
characters of the bar code could represent the lot number, characters 6 to 10 could represent the weight and
characters 11 to 14 could represent the serial number.
In the Header Block of SCPR, you define your scan profile code, description and total length. In the Detail
Block of SCPR, you define whether the bar code is inbound or outbound, its type (weight, serial number, etc.),
starting and end position, the action required when it is scanned and its data type. You can have as many
records in the Detail Block as you require. For example, if a bar code consists of three parts (one for the
weight, one for the level 2 value and one for the serial number), you would set up three records in the Detail
Block for that scan parameter profile.
If you are capturing weights, serial numbers or a temperature, the profiles that you set up in SCPR must be
attached to the appropriate items in ITEM. If you are capturing inventory levels that were unknown at the time
of receipt entry (that is, blind receiving), the SCPR profile(s) are NOT attached to the appropriate items in
ITEM.
NOTE SCPR only supports bar code scanning of items with no more than two
SKU’s in their quantity breakdown (for example, pallet/case). You cannot scan bar
codes of items with three or more SKU’s in their quantity breakdown (for example,
pallet/case/each).
FIELD DESCRIPTIONS
Description Mandatory
Scan Profile Industry If you enter 128, your label will be defined as a UCC-128 label.
Type
6 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR)
FIELD DESCRIPTIONS
Set this flag to Yes if the bar code that you are attaching your scan parameter
profile to is a variable length bar code. Otherwise, set the flag to No.
F I E L D D E S C R I P T I O N S ( D E TA I L B L O C K )
Inbound/Outbound I = Inbound
O = Outbound
B = Both
If you specify I for Inbound, the portion of the bar code that you are capturing
is restricted to an inbound RF process. If you specify O for Outbound, the por-
tion of the bar code that you are capturing is restricted to an outbound RF pro-
cess. If you specify B for Both, the portion of the bar code that you are
capturing can be used in either an inbound or outbound RF process.
Sequence Mandatory
In this field, you specify the sequence of each scanned in value. The
sequence that you enter need not match the physical layout of the bar coded
label.
You can extract an inventory level from multiple sequences in a bar code. For
example, if your bar code is 0123456789, you can define two sequences for
the level 3 value: sequence 1 for positions 1 to 2 and sequence 2 for positions
9 to 10. Your level 3 value extracted from the bar code would be 0189.
RF GUIDE 4.0.1* 7
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR)
F I E L D D E S C R I P T I O N S ( D E TA I L B L O C K )
The type of value that you are capturing. If a portion of the bar code that you
are scanning contains information that you do not wish to capture, you can
use the IGNO (Ignore Entry) option. Any part of a bar code assigned this type
will not be captured by AccellosOne 3PL.
NOTE If you use two or more values such as CUBE, HGT, LEN and WID in
the same scan parameter profile, each value must be captured on a separate
label. Only the values of SER, LEV1/2/3/4, UI, WGTG and WGTN can be
combined together and captured from a single label.
* For the serial number portion of the UCC-128 label only if you are cap-
turing a serial number and net weight.
The position of the start character of the value that you are capturing. For
example, if the total length of your bar code is 10 characters and the portion of
the bar code that you are capturing is position 3 through 7, you would enter 3
in this field.
The position of the last character of the value that you are capturing. For
example, if the total length of your bar code is 10 characters and the portion of
the bar code that you are capturing is position 3 through 7, you would enter 7
in this field.
You can also define the end position by leaving this field blank and entering
the appropriate value in the Length field.
8 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR)
F I E L D D E S C R I P T I O N S ( D E TA I L B L O C K )
The number, letter or special character indicating the start of the portion of the
bar code that you wish to capture.
The number, letter or special character indicating the end of the portion of the
bar code that you wish to capture.
The length of the portion of bar code that you are capturing If you are using
the UCC-128 label, the length is usually 48.
01 = Entry
02 = Validation
If you select Entry, validation may or may not occur depending on the value
being captured. If you select Validation, AccellosOne 3PL validates the value
against a list of valid values.
Date Format In this field you can specify the date format of any dates scanned in from a
SSCC label and saved in AccellosOne 3PL as an inventory level.
Unit of Measure Code Only required if you enter a weight, cube or linear measurement in the Type
field
RF GUIDE 4.0.1* 9
GENERAL SETUP PROGRAMS
Scan Parameter Profile (SCPR)
F I E L D D E S C R I P T I O N S ( D E TA I L B L O C K )
This field controls the formatting of values that you capture. If you select
DATE, the number that you enter will be formatted as a date. If you select
MONY, the number that you enter will be formatted in dollars and cents (for
example, $99.99).
Decimal Position Only applicable to scanned in values with a data type of MONY or NUM
The position of the decimal point. For example, if you specify 2 and your cap-
tured value is 12345, AccellosOne 3PL will record the value as 123.45. If you
do not specify the position of the decimal point, all numbers will be captured
as integers.
Weight Modifier Only applicable to scanned in values whose unit of measure code is a weight
(KGS or LBS)
If required, you can specify a weight modifier and the scanned in weight will be
multiplied by the modifier.
P = Position-Based
L = Left Starting Position
R = Right Starting Position
Item code validation allows you to validate the item code in RFOPS and
UOPR when the item code in the bar code is shorter than the item code in
ITEM. That is, the level 1 in the bar code is a subset of the full level 1 in ITEM.
In this field, you specify the position of the item code in the bar code.
10 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Bar Code Profile Code (BAPR)
F I E L D D E S C R I P T I O N S ( D E TA I L B L O C K )
Item Code Length for The number of characters from the right or left that comprise the item code.
Right/Left Starting Posi-
tion
SCPR (Scan Parameter Profile) screen showing scan parameters for scan profile code L12
In this program, you set up your bar code profile codes. Bar code profile codes are only required if you wish to
scan in inventory levels or UI (Unique Identifier) values that are embedded in a bar code label. If the value
that you are scanning is not embedded in another code (that is, the level 1 or 2 or 3 label contains no other
value or extra characters), you do not need to set up a bar code profile in BAPR.
RF GUIDE 4.0.1* 11
GENERAL SETUP PROGRAMS
Bar Code Profile Code (BAPR)
UI values can be scanned in RFCH, RFPIC and many other RF programs. Inventory levels, on the other
hand, can only be scanned in RFCH. For each profile that you set up in BAPR, you define the value being
scanned (LEV1, LEV2, LEV3, LEV4, UI), the scan parameter code to which it is attached, the bar code length
and the bar code ID.
If you are capturing two or more inventory levels in RFCH, you can do so from multiple bar code labels. For
example, you could scan in levels 1 and 2 from bar code label A and level 3 from bar code label B.
Consider the following SCPR and BAPR setups for various bar coded labels. In the following examples, “---”
represents an inventory level, UI, weight or serial number that you wish to capture, while “999” represents
non-AccellosOne 3PL information in the bar code that you do not wish to capture.
999---L1--- A profile with one detail record The SCPR profile set up in the N/A
whose type is set to LEV1. previous column must be
attached to a bar code profile
whose bar code type is set to
LEV1.
---L2---999 A profile with one detail record The SCPR profile set up in the N/A
whose type is set to LEV2. previous column must be
attached to a bar code profile
whose bar code type is set to
LEV2.
---L1---L2---L3--- A profile with three detail The SCPR profile set up in the N/A
records: one whose type is set to previous column must be
LEV1, another whose type is set attached to a bar code profile
to LEV2 and a third whose type whose bar code type is set to
is set to LEV3. LEV1.
999---L1--- Two profiles required: one with a Two records required: one for the N/A
detail record set to LEV1 and level 1 label and one for the level
---L2---999 one with a detail record set to 2 label. The appropriate SCPR
LEV2. profile must be attached to each
record.
999---L1---999---L2---999 Two profiles required. The first Two records required: one for the N/A
profile will contain two detail level 1/2 label and one for the
999---L3---999 records: one set to LEV1 and level 3 label. The appropriate
one set to LEV2. The second SCPR profile must be attached
profile will contain a single record to each record.
set to LEV3.
---UI---999 A profile with one detail record The SCPR profile set up in the N/A
whose type is set to UI. previous column must be
attached to a bar code profile
whose bar code type is set to UI.
12 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Bar Code Profile Code (BAPR)
999---WEIGHT--- A profile with one detail record N/A The SCPR profile must
whose type is set to WGTG or be attached to the item.
WGTN.
FIELD DESCRIPTIONS
Description Mandatory
Bar Code Type The following bar code types are supported:
LEV1 (Inventory Level 1)
LEV2 (Inventory Level 2)
LEV3 (Inventory Level 3)
LEV4 (Inventory Level 4)
UI (Unique Identifier)
SER (Serial Number)
YYMMDD
NOTE When the same label contains two or more inventory levels in
SCPR, the bar code type is set to the lowest inventory level. For example, if
your label format is 999---LEV2---LEV3, your bar code type would be set to
LEV3, which is the lowest inventory level.
RF GUIDE 4.0.1* 13
GENERAL SETUP PROGRAMS
Bar Code Profile Code (BAPR)
FIELD DESCRIPTIONS
The bar code’s ID. This ID identifies the manufacturer of the product. The
number of characters in this field must equal the end position - the start posi-
tion + 1.
NOTE Although bar code ID’s are optional in BAPR, they should be used
whenever they are available. If you do not specify a bar code ID, operators will
be confronted with a pick list whenever two bar codes have the same length. If
the RF operator selects the wrong code from the pick list, he or she could cap-
ture bad data.
Variable Length Only available for variable length bar codes based on the GS-1 standard.
The total length of the bar code. This length must match the length of the scan
parameter profile code in SCPR.
Size of Fixed Part in Vari- Only available for variable length bar codes based on the GS-1 standard.
able Length Bar Code
ASCII Value of Separator Only available for variable length bar codes based on the GS-1 standard.
in Variable Length Bar
Code
See your Accellos implementation consultant for further information on this
field.
14 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
BAPR (Bar Code Profile Code) screen showing setup for bar code L12
RF Profile (MRFP)
In this program, you set up your RF profile code. The RF profile code defines the default values and available
options in the core RF programs. Once you set up your RF profile code in MRFP, you must attach it to the
appropriate customer(s) in CUST.
RFCH QUERIES
This tab shows your RFCH query options.
RF GUIDE 4.0.1* 15
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H Q UE R I E S )
If you set this field to Yes, you can customize the RFCH pick list in query
mode. For example, if you set the Receipt Number and Warehouse Code
fields to Yes and all the other fields to No, only the receipt number and ware-
house code will appear in the RFCH pick list when you perform a query.
If you set this field to No, you cannot customize the RFCH pick list and all val-
ues — customer code, receipt number, receipt line number, all inventory lev-
els, etc — will display in this list.
16 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H Q UE R I E S )
Receipt Number If you set this field to Yes, the receipt number will appear in the RFCH pick list
when you perform a query.
Receipt Line Number If you set this field to Yes, the receipt line number will appear in the RFCH pick
list when you perform a query.
Inventory Level 1 If you set this field to Yes, inventory level 1 will appear in the RFCH pick list
when you perform a query.
Inventory Level 2 If you set this field to Yes, inventory level 2 will appear in the RFCH pick list
when you perform a query.
Inventory Level 3 If you set this field to Yes, inventory level 3 will appear in the RFCH pick list
when you perform a query.
Inventory Level 4 If you set this field to Yes, inventory level 4 will appear in the RFCH pick list
when you perform a query.
Warehouse Code If you set this field to Yes, the warehouse code will appear in the RFCH pick
list when you perform a query.
Quantity If you set this field to Yes, the quantity will appear in the RFCH pick list when
you perform a query.
Hold Code If you set this field to Yes, the hold code will appear in the RFCH pick list when
you perform a query.
RFCH ONLY
This tab shows various RFCH options.
RF GUIDE 4.0.1* 17
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
If you enter a document code in this field, the RF operator will be prompted to
print the document in RFCH should he/she create a new receipt line. The doc-
ument code that you enter in this field must have a document type of LA
(Label) in DOCU.
18 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
RFCH screen showing prompt for temperature and trailer number information
Perform Trailer Checks Only available if the entry of trailer numbers is activated in the Show Tempera-
ture and Pallet Blocks field
Yes
No
If you set this flag to Yes, the RF operator will be prompted to perform a series
of trailer checks. If you set this flag to No, the RF operator will NOT be
prompted to perform any trailer checks.
RF GUIDE 4.0.1* 19
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
If you select option 1, the RF operator can create new receipt lines in RFCH
with the CL (Create Lines) command and will be prompted to either mark a
receipt as complete or create a new line when finishing the last line of a
receipt.
If you select option 2, the RF operator cannot create new receipt lines in
RFCH and will not be prompted to do so when finishing the last line of a
receipt.
If you select option 3, the RF operator will NOT be prompted to either mark a
receipt as complete or create a new line and the header flow of the receipt will
NOT be advanced.
If you select option 4, the RF operator can only add a new line if the new line
consists of an existing inventory entity on the receipt. For example, the RF
operator receives 20 cases for pallet ID 123 and later discovers an additional
case for the same pallet ID. That case can be added, but a case for pallet ID
456 (which is not on the receipt) cannot be added.
20 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
This flag allows the RF operator to check for duplicate inventory in RFCH
when the line type is U for Unknown in ENRE. If you select option 1, no pop-
up message will appear when the RF operator receives duplicate inventory in
RFCH.
If you select option 2, a pop-up message will appear when the RF operator
receives a duplicate inventory entity and he/she will be prompted to accept or
reject the duplicate scan.
If you select option 3, a pop-up message will appear when the RF operator
receives a duplicate inventory UI and he/she will be prompted to accept or
reject the duplicate scan.
If you select option 4, the RF operator will not be allowed to receive a dupli-
cate inventory entity.
If you select option 5, the RF operator will not be allowed to receive a dupli-
cate inventory UI.
Default Staging Ware- If you enter a staging location and warehouse, the Loc and Whse fields will be
house/Location Code populated with these values when you are performing two-step put-away with
manual staging. You can either accept the defaults or enter a new staging
location and warehouse.
RF GUIDE 4.0.1* 21
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
If you set this flag to No, the Tie, Hi and Loose fields in RFCH will be disabled
and the RF operator can only enter the total quantity for a receipt line.
If you set this flag to Yes, the RF operator will be required to enter the tie, hi
and loose quantities for each receipt line and the Qty field in RFCH will be dis-
abled. For example, a tie, hi and loose quantity of 5/10/03 would equal 53
cases, while a tie, hi and loose quantity of 5/10/-1 would equal 49 cases. The
Yes option is designed to force RF operators to perform more accurate counts
and reduce receiving errors.
If you set this flag to Yes With Variance Check in P-Type Lines, the following
will occur. If the line quantity calculated from the tie/hi/loose quantities entered
by the operator in RFCH does not match the expected quantity in ENRE, the
operator will be allowed to enter the tie/hi/loose quantities a second time. If
there is still no match, the variance must be processed by a supervisor in
RFCV.
This field determines whether or not the Variance screen is displayed when
the quantity entered does not match the expected quantity. If you select the
“Variance screen for all users” option, any user can process a variance. If you
select the “Variance screen for supvr. only” option, non-supervisors will not be
able to press F3 to zero out the line.
If you select the “Only allow if supvr. approved” option, when non-supervisors
press F3 to zero out the line a supervisor must sign on and approve the trans-
action.
NOTE Regardless of the option that you choose, the variance itself is
always tracked in LORE even if the Variance screen does not display.
22 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
If you select No, the RF operator cannot change the quantity breakdown for a
U-type line in RFCH. If you select Yes, the RF operator can change the quan-
tity breakdown for a U-type line in RFCH; that is, override the quantity break-
down entered in ENRE. If you select “Set Quantity Breakdown to Line
Quantity for IQBP With 2 SKU Classes”, the item’s quantity breakdown will be
automatically set to the line quantity entered in RFCH.
The following requirements must be met for the Yes and “Set Quantity Break-
down to Line Quantity ...” options:
the item is set up as a variable quantity breakdown item in ITEM
the inventory entity is new (that is, it has not been previously received in the
warehouse)
Expiry Date Rules Disable expiry date entry for U-type line
If you select this option, the expiry date entry screen will NOT display in RFCH
even though manual entry of expiry dates has been activated for the item in
ITSH.
If you leave this field blank, the expiry date entry screen will display in RFCH if
manual entry of expiry dates has been activated for the item in ITSH.
RF GUIDE 4.0.1* 23
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY)
If you select “Allow Entry/Change of Hold Code“, the RF operator can enter
new hold codes and change existing hold codes in RFCH. If you select “Disal-
low Change of Hold Code. Allow New Hold Code.’, the RF operator can enter
new hold codes but cannot change existing hold codes in RFCH.
If you select “Disallow Entry/Change of Hold Code”, the RF operator will have
access to the Hold field in RFCH but cannot change a hold code. If you select
“Skip Hold Code”, the RF operator will have no access to the Hold field and as
a consequence will not be able to change the quantity.
* The two non-default options in this field are NOT available when an item hold profile is
set up in IHOP and attached to an item in ITEM.
24 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 2 )
This field allows you to check whether the base SKU of the item being
received has a weight and cube greater than zero.
If you select “Not Required”, no check will be made of the item’s base SKU
weight and cube.
If you select “Check Weight and Cube”, AccellosOne 3PL will perform the
check. If the item fails the check, the RF operator will be forced to enter the
missing values in RFCH before receiving the receipt line. RFCH in turn will
update the missing values in the Quantity Breakdown Block of ITEM.
Extra Charge Entry Type See “Extra Charge Setup for RF” on page 81 for further information.
Concatenate Inventory Only available for U-type lines in which the RF operator selects the receipt
Level in U-Type Line number from a pick list
If you select either of these two options, a scanned in value such as a date
code (for example, 101101) will be appended to either the beginning or end of
the level 2 value.
For example, office staff create a U-type receipt line in ENRE and enter the
level 2 value normally. In RFCH the RF operator scans in a value and that
value is concatenated to the level 2 value entered in ENRE.
If you select Yes, the RF operator can skip the Location field after his or her
first entry and put-away the remaining receipt lines in the same location.
If you select Yes, the RF operator can switch from one-step put-away to two-
step put-away (or vice versa) in RFCH.
RF GUIDE 4.0.1* 25
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 2 )
Special Receiving Mode U Line Receiving, Enter UI, Scan Serial as Inventory Level
Types RFCH to Gen Stag Loc, RFPU to PnD Loc, Then to Final Loc*
RFCH to Gen Stag Loc, RFPU to PnD Loc, Then to Final Loc
RFCH Overrides*
In this field, you can select a special receiving type mode required for your
facility. If you leave this field blank, special receiving type modes will be deac-
tivated.
*These two special receiving mode types require special setup. See the section on
three-step put-away in “Unloading Product in RFCH”.
Validate Inventory Level Your scan parameter profile code for validating inventory levels in RFCH
from Bar Code Using receiving. This code is a default scan parameter code at the customer level. In
SCPR Code ITEM, you can override your customer default by entering an SCPR code in
the Scan Parameter Code for Inventory Validation (SCPR) field.
If you select Door Not Used, the RF operator cannot select or change a door
assignment. If you select Enter/Update Door in RFCH, the RF operator can
enter/change a door assignment.
If you select No, the item’s quantity breakdown will be suppressed in RFCH. If
you select Yes, the item’s quantity breakdown will be displayed in RFCH.
26 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 2 )
If you select Yes, the RF operator can put-away multiple pallets in the same
location in a single step; that is, the RF operator scans two or more UI’s in
RFCH but only enters the location once.
If you select No, the item’s quantity breakdown cannot be changed in RFCH. If
you select Yes, the RF operator can change the quantity breakdown in RFCH;
that is, override the quantity breakdown entered in ENRE. If you select “Set
Quantity Breakdown to Line Quantity for IQBP With 2 SKU Classes”, the
item’s quantity breakdown will be automatically set to the line quantity entered
in RFCH.
The following requirements must be met for the Yes and “Set Quantity Break-
down to Line Quantity ...” options:
the item is set up as a variable quantity breakdown item in ITEM
the inventory entity is new (that is, it has not been previously received in the
warehouse)
RF GUIDE 4.0.1* 27
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 2 )
If you select Yes, the RF operator can override the expiry date for P-type lines
in RFCH. The item shipping profile (ITSH) attached to the item must have
expiry date entry activated (Enter Expiry Dates = Yes).
28 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 3 )
Yes
No
If you select Yes, you can capture images when unloading first UI. If you
select No, image capture will be deactivated when unloading first UI.
Yes
No
If you select Yes, you can capture images when placing UI on hold. If you
select No, image capture will be deactivated when placing UI on hold.
In this field, you specify your receiving rules when the quantity entered in
RFCH is less than the quantity received in ENRE.
EXAMPLE
quantity entered (ENRE) = 100 CS
quantity received (RFCH) = 99 CS
With option 1, AccellosOne 3PL will create a second line with a quantity of 1.
With option 2, the RF operator will be prompted to zero out the second line. If
the RF operator selects Yes, the result will be option 3; if the RF operator
selects No, the result will be option 1.
With option 3, AccellosOne 3PL will automatically create a second line with a
quantity of 0.
If you select Yes, you can receive mixed pallets in RFCH for items with the
same ILOP code. If you select No, you cannot receive mixed pallets in RFCH.
RF GUIDE 4.0.1* 29
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 3 )
In this field, you can activate grocery style scanning in RFCH. Grocery style
scanning is used when receiving product such as clothing that does not come
in a standard pallet/case quantity breakdown and therefore each piece
received must be individually scanned.
One scan can represent a quantity of one for that item or any other quantity
that you define. AccellosOne 3PL will calculate the count automatically based
on the number of pieces scanned and your setup in ALIT.
Sort Sequence Code This sort sequence code allows you to define a custom sort sequence for
(SOSE) receipt lines in RFCH. When you enter RFCH and key in a receipt number, the
receipt lines will be sorted according to your SOSE code. If you leave this field
blank, receipt lines in RFCH will be sorted in receipt line number order.
30 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H O NLY 3 )
Allow Skipping of Level Only applicable if the Validate Inventory Level from Bar Code Using SCPR
Validation Code field is activated.
No
Yes
If you set this flag to Yes, the RF operator can continue to receive a receipt
line in RFCH even if inventory level validation based on SCPR fails.
Special Item Process Execute Item Process Capture Before Staging Location Entered
Capture Mode
If you select Execute Item Process Capture Before Staging Location Entered,
the RF operator scans process values before entering a staging location. If
you leave this field blank, the RF operator scans process values after entering
a staging location.
RFCH SHARED
This tab shows options available in both RFCH and RFPU.
RF GUIDE 4.0.1* 31
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H S H AR E D)
If you select Yes, AccellosOne 3PL will display the received quantity of the
receipt line from ENRE as the default quantity in RFCH/RFPU. You can press
Enter to confirm it in these programs or you can enter a new quantity.
If you select No, the received quantity from ENRE will not be displayed in
RFCH/RFPU.
If you select RFPU Only, AccellosOne 3PL will display the received quantity of
the receipt line from ENRE as the default quantity in RFPU.
If you select Variance Screen Only, AccellosOne 3PL will display the received
quantity of the receipt line from ENRE only on the Variance screen.
If you select option 1, the entered quantity in RFCH/RFPU must match the
expected quantity in ENRE. If the two quantities do not match, the RF opera-
tor will not be able to process the receipt line.
If you select option 2, the entered quantity in RFCH/RFPU need NOT match
the expected quantity in ENRE and a warning message is only generated
when the received quantity is greater than the expected quantity.
If you select option 3, a warning message will be generated when the entered
quantity in RFCH/RFPU does not match the expected quantity in ENRE, but
the RF operator will be allowed to proceed.
32 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H S H AR E D)
If you select option 5, matching is not required in RFCH. However, the entered
quantity in RFPU cannot exceed the expected quantity in ENRE.
If you select option 6, the entered quantity in RFCH must match the expected
quantity in ENRE and the entered quantity in RFPU cannot exceed the
expected quantity in ENRE.
RFCH Only
RFPIC Only
RFCH and RFPIC
RFCH Only in Supervr. Override Mode
None
This flag allows the RF operator to validate the serial number and other infor-
mation such as level 1 and 2 values in bar code labels. Validation will only
occur for P-type receipt lines when the full quantity is received and all process
values have been entered or scanned in.
If you set this field to RFCH Only, RFPIC Only or RFCH and RFPIC, the RF
operator will be prompted to scan in one label from each pallet for validation
purposes in the appropriate program. Should the label be missing or not valid,
the RF operator will not be able to complete the receipt in RFCH or the order
in RFPIC.
RF GUIDE 4.0.1* 33
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H S H AR E D)
If you set this field to RFCH Only in Supervr. Override Mode, the RF operator
will be prompted to scan in one label from each pallet for validation purposes
in RFCH. Should the label be missing or not valid, the RF supervisor login
screen is displayed. When the supervisor logs in, he or she will be prompted
to select how long to turn off process value validation: either turn off for just
that pallet or for all pallets on that receipt or all pallets of that item on that
receipt.
If you set this flag to None, no validation of the serial number or other informa-
tion on a bar code label will occur.
The No option allows you to add new receipt lines after all receipt lines on a
receipt have been confirmed.
Maximum Quantity In this field, you specify the maximum quantity for any given receipt line in
Allowed in RFCH/RFPU RFCH/RFPU. If you do not enter a number, the maximum quantity allowed in
RF receiving for a receipt line is 9999.
34 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S ( R F C H S H AR E D)
If you select No, partial pallet put-away to a reserved area is deactivated and
normal put-away rules to a non-reserved area apply.
If you select Yes, partial pallet put-away to a reserved area is activated and
the following logic applies:
if received quantity = zero or null, halt the receiving process and send a
“SEE SUPERVISOR” message to RF operator
if received quantity = standard quantity breakdown, pallet is deemed to be a
full pallet
if received quantity < standard quantity breakdown, pallet is deemed to be a
partial pallet
if received quantity > standard quantity breakdown, halt the receiving pro-
cess and send a “SEE SUPERVISOR” message to RF operator
If you select Yes With Allowing Over a Pallet as Full Pallet, the same logic as
Yes will apply with the following exception:
if received quantity > standard quantity breakdown, no message is gener-
ated and normal put-away continues
RFPU
This tab shows various RFPU options.
RF GUIDE 4.0.1* 35
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
RFPU tab
If you select “Stop operator from proceeding”, the RF operator will not be able
to put-away product in RFPU to a pick line location that is not set up for that
product in PIIT. If you select “Omit validation of location”, the RF operator will
able to put-away product to any pick line location without restriction.
If you select No, the RF operator cannot put-away product to a staging loca-
tion in RFPU. If you select Yes, the RF operator can perform three-step put-
away; that is, put-away product to a staging location in RFPU. When product
is assigned to a staging location, the receipt’s flow remains at STPU (Start
Put-Away) and is not advanced to PUCO (Put-Away Complete) until a non-
staging location is eventually entered.
36 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select “Variance screen deactivated”, the Variance screen does not dis-
play for any user. If you select “Variance screen no sup. override”, the Vari-
ance screen displays for all users and no supervisor override is required to
enter a variance. If you select “Variance screen with sup. override”, the Vari-
ance screen displays for all users and a supervisor override is required to
enter a variance. If you select “Variance screen for sup. only”, the Variance
screen displays for supervisors only and no supervisor override is required to
enter a variance.
NOTE Regardless of the option that you choose, the variance itself is
always tracked in LORE even if the Variance screen does not display.
Validation Rules for Sys- No validation for system-assigned locations and overrides allowed
tem-Assigned Locations Validation required WHEN system assigns location and overrides
allowed
Validation required ONLY for system-assigned locations and overrides
allowed
If you select “No validation”, the RF operator can press Enter in RFPU to
accept a system-assigned location without the need to re-enter it. If you select
“Validation required WHEN ...”, the RF operator must re-enter or scan in your
put-away location in RFPU to confirm it.
If you select “Validation required ONLY ...”, the RF operator must re-enter or
scan in your put-away location in RFPU to confirm it only when the location is
assigned a location type in LOTP whose Directed Put-Away flag has been set
to Yes.
Event-Driven Cycle See the Cycle Counting Guide for further information on event-driven cycle
Count Profile (CYCP) counts.
Allow Quantity to be No
Updated Yes
If you select Yes, the RF operator can enter or modify the quantity of a receipt
line in RFPU. If you select No, the cursor will skip over the Qty field and the
quantity cannot be entered or modified.
RF GUIDE 4.0.1* 37
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
f you select “Allow Entry/Change of Hold Code“, the RF operator can enter
new hold codes and change existing hold codes in RFCPU. If you select “Dis-
allow Change of Hold Code. Allow New Hold Code.’, the RF operator can
enter new hold codes but cannot change existing hold codes in RFPU. If you
select “Disallow Entry/Change of Hold Code”, the RF operator will have no
access to the hold code field in RFPU.
Maximum Number of F3 In this field, you specify the maximum number of times that the RF operator
(NX) Allowed Per ILOP can press F3 (NX) in RFPU to display a suggested put-away location.
Sequence
If you select Yes, the RF operator can put-away multiple pallets in the same
location in a single step; that is, the RF operator scans two or more UI’s but
only enters the location once. If you select No, the RF operator must put-away
each pallet individually.
* Does not support directed put-away. That is, only the flows INST and STPU can have
the Assign Location flag set to Yes.
If you select “Allow Receiving of Multiple Lines Together”, the RF operator can
put-away multiple receipt lines in a single step if the following conditions are
met:
all lines have the same UI
all lines are in the same location with the same hold code (if any)
the quantity entered is the total quantity and it is entered in the lowest SKU
NOTE If you used Directed Move Inbound to assign locations and the pal-
let has mixed items, the ILOP profile from the item with the largest quantity in
the pallet is used to produce a to location.
38 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
RFPIC
This tab show various RFPIC/RFPK options.
RFPIC tab
RF GUIDE 4.0.1* 39
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select “Only Case Picking”, the RF operator cannot select pallet or nor-
mal mode (NM) in RFPIC. If you select “Only Pallet Picking”, the RF operator
cannot select case pick mode (CP) in RFPIC (unless he or she is picking from
a pick line location). If you select “Pallet Picking”, the RF operator will be
prompted to confirm pallet or normal mode (NM) as the default picking mode
in RFPIC. If you select “Case Picking (CP)”, the RF operator will be prompted
to confirm case pick mode as the default picking mode in RFPIC.
Once the RF operator selects a mode in RFPIC, that mode remains in effect
for all orders until the RF operator exits RFPIC or changes his or her mode by
pressing F2.
If the RF operator is picking from a pick line location, the mode is automati-
cally set to Case Picking regardless of the option that the RF operator selects
in this field.
If you select 1, duplicate pallet ID’s will be allowed without restriction. If you
select 2, duplicate pallet ID’s will never be allowed.
40 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
This flag governs which order lines appear in the RFPIC pick list when work-
ing in normal mode.
If you select “Allow all, no restriction”, all order lines regardless of pick quantity
appear in the RFPIC pick list. If you select “Allow last remaining partial inven-
tory and full pallets”, only full pallet picks and partial quantities representing
the last remaining inventory in a location appear in the RFPIC pick list.
If you select “Allow full pallets only”, only full pallet picks appear in the RFPIC
pick list. The RF operator must switch to case pick mode to pick partial order
lines.
A partial quantity is defined as 60% or more of the total quantity in the loca-
tion. For example, if there are 50 cases in a location and you need to pick 30,
you can scan in the 20 cases to be removed rather than the 30 cases to be
picked. This option is designed to save time by reducing the number of cases
scanned.
If you select “PALL pick method only”, only full pallet picks generated by the
Wave Manager appear in the RFPIC pick list.
If you set this flag to “In NM Mode”, the lowest level or pallet ID will be added
to the Process Block of the order under the code CP for case pick when pick-
ing full pallets or picking the last entity in a location in normal mode.
If you set this flag to No, the lowest level or pallet ID will NOT be added to the
Process Block of the order under the code CP for case pick.
If you set this flag to “In CP Mode as the first pick”, the lowest level or pallet ID
will be added to the Process Block of the order under the code CP for case
pick after the first pick in case pick mode.
RF GUIDE 4.0.1* 41
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
Number of Days for Label The “value greater than zero” option requires a custom label from Accellos.
Validation
If you enter a value greater than zero in this field, AccellosOne 3PL will vali-
date a case’s date in RFPIC. Should the Number of Days for Label Validation
value be less than the order to arrive date minus the date embedded in the
case's bar code label, the message “Too old for order” will display and you will
not be able to pick the case.
If you enter zero or leave this field blank, the RF operator can scan in the
cases to be removed from a full pallet rather than the cases to be picked when
picking a partial quantity.
With both these options, the order line will be split into two: line 1 will contain
the pick quantity and line 2 will contain the remaining quantity that could not
be picked. Line 2 will be placed on suspended hold and AccellosOne 3PL will
attempt to reallocate the line 2 quantity.
42 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
With both these options, the order line will be split into two: line 1 will contain
the pick quantity and line 2 will contain the remaining quantity that could not
be picked. Line 2 will NOT be placed on suspended hold and AccellosOne
3PL will NOT attempt to reallocate the line 2 quantity.
NOTE The option that you select in this field can be overridden at the item
level in the program MIRP (Item RF Profile Code) by selecting a different
option for a given item.
If you select Yes, the RF operator cannot scan process values in RFPIC.
Instead, he/she must scan these values in UOPR. If you select No, the RF
operator can scan process values in either program.
This flag allows you to pick pick line product from a non-pick line location such
as bulk or rack when multiple replenishments for the same product cause
overcrowding in your pick line. This choice is available when the full order
quantity is not available in the pick line location and a replenishment has been
generated.
For example, suppose your order quantity is 10 cases, there are only five
cases in the pick line and the replenishment quantity is 60 cases. The RF
operator can choose to pick the 10 cases from a bulk or non-pick line location
instead of waiting for a replenishment and picking from the pick line. The 10
cases picked from bulk is subtracted from the replenishment quantity; 60 -10 =
50.
If you select Yes, pick line picking from a non-pick line location is activated. If
you select No, pick line picking from a non-pick line location is not allowed.
If you select “REPI is done inside of RFPIC”, the RF operator can perform
replenishments in RFPIC. If you select “REPI is done separately”, the RF
operator can only perform replenishments in RFRP or RFPL. If you select
“Determined by the user”, each time that the RF operator logs in, he/she will
be prompted to select a replenishment mode.
RF GUIDE 4.0.1* 43
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
Display Original Order Only available for consolidated picking after consolidating your orders in COPI
Number/Quantity for Con- (Consolidated Picking)
solidated Picks
No Display
Display at UI Field
If you select No Display, the original order number and quantity will not be dis-
played when the RF operator selects a consolidated line. If you select Display
at UI Field, RFPIC will display the original order number, quantity and SKU in
a pop-up window after the RF operator selects the UI value.
44 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select “Do not display”, the Pallet Block will not display in RFPIC and the
RF operator will not be able to ship, receive or exchange pallets in this pro-
gram. If you select “Display before Picking”, the Pallet Block will display before
picking in RFPIC. If you select “Display on Completion of Picking”, the Pallet
Block will display after picking in RFPIC.
If you select “Display after RFSC”, the Pallet Block will display after performing
manual cartonization in RFSC.
RFPIC (2)
This tab shows additional RFPIC/RFPK options.
RF GUIDE 4.0.1* 45
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select one of the line options (every 2nd, 3rd, 4th, etc. line), a count will
be required only for every 2nd, 3rd, 4th, etc. pick.
46 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
These rules govern what happens in RFPIC when the inventory count for the
location that is entered by the RF operator does not match the on hand quan-
tity.
Ignore investigations
No record will be created in ICIN (Inventory Count Investigation) and the RF
operator can pick the order line.
Threshold Quantity to Ini- Only available if you select If Quantity Reaches or Falls Below Threshold
tiate Count Quantity in the Activate Inventory Count / Hold field
RF GUIDE 4.0.1* 47
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select No, the RF operator has two choices when prompted for a pallet
ID in RFPIC while in case pick mode:
he or she can press Enter to have AccellosOne 3PL generate a unique pal-
let ID
he or she can enter or scan in a pallet ID not generated in AccellosOne 3PL.
The Yes option requires a label document in either the Label Document or
Quick Response Label Document fields. If all your consignees use quick
response labels, a label document is not required in the Label Document for
RF Picking field. If some consignees use quick response labels while others
do not, you must enter a label document in both fields.
If you do not use quick response labels, a label document is not required in
the Quick Response Label Document field.
If you select SSCC18 Pallet Sequence Number, the unique pallet ID gener-
ated in RFPIC will be a valid SSCC 18 pallet sequence number.
If you enter a label document in this field, the Label field in RFPIC when work-
ing in CP (case pick) mode will be populated with the label document number.
If you set up a detail record in DOCU for this document specifying both the
printer and operator, the Printer field in RFPIC will be populated with the RF
operator’s printer.
If you enter a label document in this field, the Label field in RFPIC when work-
ing in CP (case pick) mode will be populated with the quick response number.
If you set up a detail record in DOCU for this document specifying both the
printer and operator, the Printer field in RFPIC will be populated with the RF
operator’s printer.
48 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
The sort sequence code used to sequence or “snake” the pick list of picking
tasks in RFPIC. You can apply these advanced SQL statements to either item
codes, location codes or inventory entities.
When you activate sort sequencing, the RF operator can initially pick any item,
location or inventory entity from the sorted list, but once this initial choice is
made the RF operator must finish picking the item, location or inventory entity
in RFPIC before proceeding to another item, location or inventory entity.
For example, suppose you set up a sort sequence based on item and there
are three different items on a given order: item A, item B and item C. When the
RF operator enters RFPIC and selects any item on the order — say item B —
he or she must pick all order lines containing item B before picking another
item. The same logic applies to the remaining items on the order; once a given
item is selected, all order lines containing that item must be picked before pro-
ceeding to another item.
Pick list in RFPIC shown in location code sequence (A107, A107, B102)
If you do not specify a sort sequence code, picking tasks in the pick list will be
sequenced in location code sequence.
RF GUIDE 4.0.1* 49
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
Event-Driven Cycle See the Cycle Counting Guide for further information on event-driven cycle
Count Profile (CYCP) counts.
Enter Outbound Pallet ID Only available for case pick mode in RFPIC/RFITLV
Before Picking
No
Yes
If you select No, the RF operator must enter label parameters after picking his/
her order line(s). If you select Yes, the RF operator must enter label parame-
ters before picking his/her order lines.
In this field, you set your label printing options for the outbound pallet ID label
in RFPIC and RFPK.
50 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
If you select option 1, no label will print and the PRT field will be bypassed.
If you select option 2, the RF operator must press Enter in the LABEL field to
generate an AccellosOne 3PL OPID. Then he/she scans in this OPID to vali-
date it.
If you select option 3, the RF operator must press Enter in the LABEL field to
generate an AccellosOne 3PL OPID, but does not perform a scan to validate
it.
If you select option 4, the RF operator must manually enter or scan in your
own non-AccellosOne 3PL OPID. If you select option 5, the RF operator must
manually enter or scan in your own non-AccellosOne 3PL OPID twice.
Extra Charge Entry Type See “Extra Charge Setup for RF” on page 81 for further information.
RFPIC (3)
This tab shows additional RFPIC/RFPK options.
RF GUIDE 4.0.1* 51
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 3 )
Display Location/UI Rules Display Location/UI When Picking from Pick Line
Display Location/UI for All Locations
Display and Bypass Location/Qty in NM Mode
Display and Bypass UI (non-reserve)
Display and Bypass UI When Picking from Pick Line
Skip Location-From and Go to UI; Show Line Qty and Skip Qty field in
NM Mode
Depending on the option that you choose, you can speed up picking by elimi-
nating certain key strokes and validations in RFPIC.
If you define segregation rules for hazardous product in IHZV (Item Hazard-
ous Material Validation) and set this flag to Yes, your segregation rules will
apply to RFPIC and RFMG. If you set this flag to No, any segregation rules
defined in IHZV will be ignored in RFPIC and RFMG.
Rules for Picking by Item/ Validate Item/UPC for All Locations (1)
UPC Validate Item/UPC in Pick Line Locations (2)
No (3)
If you select option 1 or 2, the UPC code scanned by the operator will be
checked against the UPC code set up in ALIT. If the inventory levels linked to
the UPC code in ALIT match the inventory levels of the pick order line, the
pick will be accepted as valid. If, on the other hand, the inventory levels linked
to the UPC code in ALIT do NOT match the inventory levels of the pick order
line, the pick will be rejected.
Option 1 performs the validation for all locations, while option 2 performs the
validation for pick line locations only.
If you select option 3 (No), no validation of the level 2/3/4 values in ALIT will
occur. For one-level accounts only, the operator can scan in either the item
code (level 1) or the UPC code.
52 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 3 )
In RF Pick
In RF Sorting
If you select In RF Pick, the RF operator can capture in RFPIC the cubic
dimensions in meters and the gross weight in kilograms for each carton/pallet.
If you select In RF Sorting, the RF operator can capture in RFSC the cubic
dimensions in meters and the gross weight in kilograms for each carton/pallet.
If you leave this field blank, the capture of cubic dimensions and gross weight
will be deactivated in RFPIC and RFSC.
Use Bookmark in Picklist Yes option not available if Sort Sequence Code (SOSE) field populated
No
Yes
If you select Yes, the first order line in the picklist selected by the RF operator
will be bookmarked. When the RF operator finishes picking that line and
returns to the pick list, the pick list will display the next order line after the
bookmark rather than the first order line in the pick list.
If you select Yes, pick method 7 (Less Than Full Pallet) will be activated in
RFPK.
RF GUIDE 4.0.1* 53
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 3 )
If you select “Override Required for Reduce Order Qty Only”, a supervisor
override is required when the RF operator reduces the order quantity. For
example, the order quantity is 10 eaches, there are 10 eaches in the location
and RF operator picks five eaches.
If you select “Not Required for Exceptions”, the RF operator can reduce the
order quantity and/or short an order line without a supervisor override.
Automatically Confirm No
Order After Last Pick Yes
If you select Yes, the order will be automatically confirmed when the RF oper-
ator picks the last line. If you select No, the order must be manually confirmed
in CHOF.
NOTE The Yes option does not allow any flows between FIPI (Finish Pick-
ing) and COOR (Confirm Order).
If you select Yes, the RF operator must enter a valid pallet type defined in
PALL in RFPIC. If you specify a pallet code for a consignee in the Pallet Code
field in CONS, RFPICK will validate that any pallet code entered during order
picking for that consignee will match the consignee's pallet code.
RFPIC (4)
This tab shows additional RFPIC/RFPK options.
54 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
RF GUIDE 4.0.1* 55
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 4 )
If you select Yes, RFRL (RF Relocate) will display whenever the RF operator
enters an “invalid UI”; that is, the UI is in the correct location, but is not allo-
cated to the order. If you select No, an error message will display whenever
the RF operator enters an “invalid UI” and RFRL will not be available.
If you select “Display and Pick in Lowest SKU”, pick quantities will always dis-
play in the lowest SKU even if this SKU differs from the SKU quantity in
ENOR. Likewise, the pick SKU entered by the RF operator will always be the
item’s lowest SKU.
If you select “Display in Order Line SKU, Pick in Lowest”, the display SKU will
be that of the order line in ENOR while the pick SKU entered by the RF opera-
tor must be the item’s lowest SKU.
If you select Yes, the RF operator in RF picking programs can pick multiple
pallets and deliver them to a staging location in a single step. This option is
available only if the MHE code is captured upon login to RF.
If you select No, the RF operator is restricted to a single pallet per pick.
56 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 4 )
Display Rules for Default Last Staging Location in Previous Pick, Scan not Required
Staging Location Display Last Staging Location from Order, Scan Required
Display Last Order Staging Location and Load Staging Location, Scan
Required
Display Last Staging Location from Order, Scan not Required
In this field, you specify your display and scanning rules for the default staging
location.
If you select Yes, the pick quantity will display in the highest UOM or SKU type
(usually PLT).
Validate OPID Using If you set up a special verifier SQL record in MSVS, you can perform custom
MSVS Code validation of your OPID’s.
RF GUIDE 4.0.1* 57
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 4 )
If you select No, the From Location field is automatically populated by Accel-
losOne 3PL and no scan by the operator is required. If you select Yes, the
from location must be scanned by the operator for each pick.
You can mask up to 25 characters of the UI from either the left or the right to
prevent RF operators from cheating by typing in rather than scanning the UI.
Inventory Count Investi- Investigation for Every Picked Unconfirmed Order and OPID
gation Type
If you select “Investigation for Every Picked Unconfirmed Order and OPID”, an
ICIN record will be created for all on order inventory in the warehouse whose
inventory levels match the inventory levels of a single picked pallet with a
countback variance.
If you leave this field blank, an ICIN record will be created for the current pallet
being picked only should that pallet have a variance during an RFPIC count-
back. All other pallets for unconfirmed orders containing the same inventory
will NOT be assigned an ICIN record.
58 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S RF P I C ( 4 )
If the supervisor enters Y for Resolved, no ICIN record will be created for the
current pallet being picked if there is a variance. However, ICIN records will be
created for all other pallets on open orders whose first three inventory levels
match the inventory levels of the current pallet.
When selecting the resolved option, the supervisor will be prompted to confirm
the quantity. If the supervisor quantity matches the system quantity, no ICIN
record is created. If the supervisor quantity does not match the system quan-
tity, one of the following will occur:
if the quantity entered is less than the system quantity, the difference will be
placed on SUSP hold and the required number of ICIN records will be gen-
erated
if the quantity entered is greater than the system quantity, the prompt “Move
excess to designated location with label” will display and the required num-
ber of ICIN records will be generated
If the supervisor enters N for Not Resolved, no ICIN records will be created
and the RF operator will be prompted to re-pick the order line.
Inventory Count Display Ignore Count When Outbound Qty = Inbound Qty = Item Setup Qty
Type
If you select this option, no inventory counts will be generated when the stan-
dard quantity breakdown (say, 50 cases per pallet) is the same as both the
inbound quantity and the outbound quantity. That is, a full pallet was received
and is now being shipped in its entirety.
MISCELLANEOUS
This tab shows various miscellaneous options.
RF GUIDE 4.0.1* 59
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
Miscellaneous tab
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S
If you select Item, order lines will be sorted in item code order in RFPI. If you
select Location, order lines will be sorted in location code order.
If you select “Picklist and validation”, the RF operator can select the from loca-
tion from a picklist and must scan in the from location to validate. If you select
“Picklist. No validation”, the RF operator can select the from location from a
picklist, but does not scan in the from location. If you select “No picklist. Must
validate”, the RF operator cannot select the from location from a picklist, but
must scan in the from location to validate.
60 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S
If you select “Stop operator from proceeding”, the RF operator will not be able
to put-away product in RFPU to a pick line location that is not set up for that
product in PIIT. If you select “Allow operator to proceed”, a warning message
will display when the RF operator attempts to put-away product to a pick line
location not set up for the product. However, the RF operator can bypass the
warning message by pressing F3 to process. If you select “Omit validation of
location”, the RF operator will able to put-away product to any pick line loca-
tion without restriction.
If you set this flag to Yes, the RF operator must enter the quantity being
moved when relocating product in RFST. The quantity being moved is the
number of cases/eaches or other SKU that has been assigned to an outbound
pallet ID in RFPIC. If you set this flag to No, the quantity being moved is not
entered when relocating product in RFST.
If you set this flag to Yes, the RF operator must enter the from location when
relocating product in RFST. If you set this flag to No, the from location is not
required.
RF GUIDE 4.0.1* 61
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S
If you set this flag to Yes, the RF operator can perform directed moves in
RFRL. AccellosOne 3PL will select the best possible to location for a reloca-
tion based on your directed move stock parameters set up in ILOP. If you set
this flag to No, the RF operator cannot perform directed moves in RFRL.
If you select Yes, AccellosOne 3PL will display the from relocation quantity in
the QTY field in RFRL and position the cursor in the LOC TO field. The RF
operator can either proceed to relocate all product in the location or can press
F9 and change the quantity.
The from relocation quantity will be displayed in “cooked” format; that is, 1 pal-
let/25 cases instead of 125 cases or 5 cases/10 eaches instead of 110
eaches. This option is designed for facilities where relocating all inventory in a
location is the rule rather than the exception.
The following conditions must be met before the from relocation quantity will
display:
all product in a given location belongs to the same inventory entity
the quantity contains more than one SKU type; for example, there are two
pallets, 20 cases in a location or 30 cases plus 10 eaches in a location.
If you select No, the from relocation quantity will not be displayed in RFRL.
Document Code for This field allows you to specify a document code for replenishment labels. A
Quantity Labels custom document from Accellos is required.
MISCELLANEOUS (2)
This tab shows additional miscellaneous options.
62 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 2 )
If you select Yes, RF operators picking in RFPK will not have access to order
lines assigned to either the CART or EACH pick method. These order lines
must be picked manually outside of RFPK.
If you select No, RF operators picking in RFPK will enjoy full access to all
order lines regardless of pick method.
RF GUIDE 4.0.1* 63
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 2 )
This field allows you to define how AccellosOne 3PL checks for duplicates in
the following RF programs: RFIPS, RFOPS and UOPR.
If you select Per Document, no duplicate serial numbers will be allowed within
the same receipt/order. If you select Per Item for a Document, no duplicate
serial numbers within will be allowed for the same item on a single receipt/
order. If you select Per Entity for a Document, no duplicate serial numbers will
be allowed within the same inventory entity on a single receipt/order. If you
leave this field blank, duplicate serial numbers will be allowed without restric-
tion.
If the MRFP rule is violated, the RF operator will not be allowed to proceed.
You can merge inventory entities at inventory levels other than the lowest. For
example, suppose you select Level 1 and merge two pallets with different lot
numbers and pallet ID's. The adjusted out lot number and pallet ID will be lost
and the adjusted in lot number and pallet ID quantity will be adjusted accord-
ingly.
If you select Yes, a blank RFRL screen will display for the RF operator after
each relocation. If you select No, RFRL will not refresh after each relocation.
64 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 2 )
In this field, you select how you want to execute a relocation. If you select
“Scan Location to Execute Relocation”, the RF operator must scan the from
location to execute the relocation and pressing F3 (Process) is not required. If
you select “UI Scan Only” in this field, the RF operator must scan the UI to
execute the relocation. If you select “Scan Location to Execute Relocation; UI
Scan Only”, the RF operator must scan both the from location and the UI to
execute the relocation.
If you select this option, you can relocate a mixed pallet (multiple items, lots,
date codes, etc.) in a single relocate action. A pallet license relocate will move
all inventory records associated with the pallet.
If you select Yes, a pop-up screen displays in RFCO showing an order sum-
mary for each OPID. The summary shows the pick method as well as the total
number of units in the OPID.
RF GUIDE 4.0.1* 65
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 2 )
For example, if you select Level 1, the RF operator will perform a count for
each item on the order. If, on the other hand, you select Level 2, the RF oper-
ator will perform a count for each lot on the order.
RFOPS Sort Sequence In this field, you can define a sort sequence for your process values in
Code (SOSE) RFOPS. For example, an unsorted list of process values might appear as fol-
lows:
carton ID
carton ID
carton ID
weight
weight
weight
After sorting, the same list of process values could appear in a more logical
order:
carton ID
weight
carton ID
weight
carton ID
weight
MISCELLANEOUS (3)
This tab shows additional miscellaneous options.
66 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 3 )
Other Inventory Count In this field, you select the RF program(s) in which you wish to perform count
Programs backs.
If you select “Always”, a count back is required each time the RF operator puts
away/relocates/replenishes product. For put-away activities, the location
counted is always the to location. For relocation and replenishment activities,
the RF operator counts the inventory in the from location.
If you select “If Quantity Reaches or Falls Below Threshold Quantity”, a count
back is only required if the quantity in the to location (for RF receiving) or the
from location (for RF relocation and replenishment) falls below the threshold
quantity that you define in the Threshold Quantity to Initiate Count field.
RF GUIDE 4.0.1* 67
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 3 )
These rules govern what happens when the inventory count for the location
that is entered by the RF operator does not match the on hand quantity. If you
select “Require Supervisor Override”, a supervisor will be required to log in
and approve the discrepancy. If you select “Ignore Investigation”, the RF oper-
ator can proceed normally to the next pick/relocation/put-away, etc.
Threshold Quantity to Ini- Only available if you select If Quantity Reaches or Falls Below Threshold
tiate Count Quantity in the Activate Inventory Count field
In this field, you define the suggested or default to location in RFST. If you
select “Follow Order”, the suggested location will be the to location where the
last OPID was staged. In other words, the suggested to location is always the
to location chosen in the previous order line.
If you select Follow “Assigned Staging Location”, the suggested location will
be the staging location assigned to the order line in either SELO or the Wave
Manager. It will not change for a given order even if the RF operator overrides
the suggested to location.
68 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 3 )
Display To-Location in Yes option only available if Suggested Location Rules in RFST is activated
RFST
Yes
No
If you select Yes, the suggested to location is displayed. If you select No, the
suggested to location is not displayed.
If you set this flag to Yes and enter an adjustment in RFAJ, you will be
prompted to enter an adjustment code (ADJU), a reason code (REAS) and
remarks for each adjustment. If you set this flag to No, you will not be
prompted for an adjustment code, reason code and remarks.
If you select Yes, the RF operator can relocate multiple pallets in the same
location in a single step; that is, the RF operator scans two or more UI’s but
only enters the location once.
MISCELLANEOUS (4)
This tab shows additional miscellaneous options.
RF GUIDE 4.0.1* 69
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 4 )
If you select Yes, the RF operator can replenish multiple pallets in the same
location in a single step; that is, the RF operator scans two or more UI’s but
only enters the location once.
70 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 4 )
If you select “Up to level 1/2/3”, the RF operator can put-away and move mul-
tiple pallets in the same location in a single step. The multiple pallets can con-
tain mixed inventory up to the inventory level selected. For example, pallets
from different receipts, appointments and inbound loads containing different
level 2’s and 3’s can be placed on the same forklift and put-away together if
you select “Up to level 1”.
This field applies to the following programs: RFCH, RFPU, RFST, RFRL,
RFRP and OLOP.
If you leave this field blank, the RF operator cannot put-away/move mixed
product in a single step.
If you select Yes, the RF operator will be required to enter a reason code in
RFCH/RFPU if he or she overrides the system-assigned location code or
requests an alternate location. The reason code will be stored on the receipt
line and a time stamp will be created.
Max. Number of F3 (NX) In this field, you specify the maximum number of times that the RF operator
Allowed Per ILOP can press F3 (NX) in RFRL to display a suggested relocate location.
Sequence in RFRL
RF GUIDE 4.0.1* 71
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 4 )
If you select Yes, the RF operator can relocate multiple pallets in the same
location in a single step; that is, the RF operator scans two or more UI’s in
RFST but only enters the location once.
If you select Yes, the item quantity breakdown will display as a pop-up mes-
sage in the following programs: RFPIC, RFPK, RFRL, RFPR, RFRP, RFCH
and RFPU.
For example, you are entering a transfer order to transfer serial number prod-
uct from one account to another.
The RF operator selects ME (Manual Entry). After entering the weight, the RF
operator can press F1 (SE) to create a new system-generated serial number.
72 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 4 )
If set to Yes, the RF operator will be required to enter the gross weight when
closing a carton in RFSC. The weight measure code for the carton will be
defined in DITP (Depositor Item Profile).
RF GUIDE 4.0.1* 73
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 4 )
Allow Put-Back of Out- In this field, you define put-back rules when the RF operator performs a partial
standing REPI Quantity replenishment (for example, less than a full pallet) because blocked or dam-
aged product is preventing a full replenishment.
EXAMPLE
Item quantity breakdown: 50 cases per pallet
replenishment quantity from bulk: 45 cases (less than a full replenishment)
order quantity: 10 cases
No
A second replenishment of five cases is created (50 - 45 = 5) for the original
pick line location.
Yes
RF operator is prompted to perform a second replenishment of 5 cases to
either the original pick line location or to another pick line location.
If you select Yes, the order line will NOT be advanced to the next flow even
though your count matches the order line quantity when you perform an out-
bound audit in RFOA. If you select No, the order line will be advanced to the
next flow when your count matches the order line quantity in RFOA.
MISCELLANEOUS (5)
This tab shows additional miscellaneous options.
74 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 5 )
If you select Yes, the OPID to value remains displayed on the screen after the
merge so that the RF operator can continue to merge into the same OPID.
If you select Yes, the following validations will occur when manually entering
catch weights and serial numbers in RFOPS:
the entry length and data type must match your setup in IPRO
If you select No, only the entry length and data type must match your setup in
IPRO.
RF GUIDE 4.0.1* 75
GENERAL SETUP PROGRAMS
RF Profile (MRFP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 5 )
NOTE The Yes option in MRFP will be ignored if you have shelf live over-
rides in CCOP (Customer/Consignee Override of PIPR) for an order triggering
a replenishment.
The purpose of the additional scan in RFSC to make sure that the serial num-
ber scanned during RFPIC is the same serial number going in the box during
packing.
For example, suppose there are 255 cases in a pick location with 305 on
order. Although there are three replenishments for a total of 144 cases, only
60 cases are needed to meet the order quantity and therefore only one replen-
ishment (the one for 60 cases) will show in demand mode.
76 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Item RF Profile (MIRP)
F I E L D D E S C R I P T I O N S M I S CE L L A N E O U S ( 5 )
NOTE
The quantity breakdown entered in RFCH will overwrite the quantity break-
down entered/set up in ENRE and EDI.
In this program, you set up your suspended hold and inventory count rules at the item level. If you define a
profile in MIRP and attach it to an item in ITEM, the suspended hold/inventory count rules in MIRP will
override your suspended hold/inventory count defaults for a given customer defined in MRFP.
MIRP screen
RF GUIDE 4.0.1* 77
GENERAL SETUP PROGRAMS
Item RF Profile (MIRP)
F I E L D D E S C R I P T I O N S ( R F P I C TA B )
Allow Suspended Holds The following options are identical to the options in the Allow Suspended
Holds field in MRFP:
Split Order Line, No Suspended Holds
Allow Suspended Holds
Only Allow if Supervisor Approved
Split Order Line, Allow Suspended Hold
Split Order Line, Supervisor Approved
The various zero out remaining quantity options allow the picker to pick any
quantity up to the order line quantity. For example, if the order line quantity is 5
cases, the picker can pick 0, 1, 2, 3, 4 or 5 cases. AccellosOne 3PL will auto-
matically zero out the remaining lines so that the order will ship without the
need to reallocate the missing product or manually delete the lines in ENOR.
If you select Yes, a pop-up box will display showing both the main item
description and the alternate description in RFCH. if you select No, no pop-up
box will display in the program.
If you select Yes, a pop-up box will display showing both the main item
description and the alternate description in RFPIC. if you select No, no pop-up
box will display in the program.
Activate Event-Driven See the Cycle Counting Guide for further information on event-driven cycle
Cycle Count in RFPIC counts.
Activate Inventory Count If you select an option in this field, it overrides the option that you selected in
MRFP.
78 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Depositor Workflow Profile (DIFP)
F I E L D D E S C R I P T I O N S ( R F P I C TA B )
Inventory Count Rules If you select an option in this field, it overrides the option that you selected in
MRFP.
Threshold Quantity to Ini- If you select an option in this field, it overrides the option that you selected in
tiate Count Back MRFP.
MISCELLANEOUS TAB
If you select any options in these fields, they override the option(s) that you selected in MRFP.
Certain flows are mandatory for inbound and outbound processing in DIFP. Refer to the appropriate program
(RFCH, RFPI, RFPIC, etc.) to see which flows are required for a given program.
RF Operator (RFOP)
In this program, you set up your RF operators and define their default company and Vocollect Voice
password. In the Detail Block, you define which task profiles they are allowed to work in as well as their
material handling type and activity type exclusions.
RF operators in RFOP are required in the following cases:
you perform voice-activated picking using Vocollect Voice
you pick by assignment in RFVP (RF Voice Pick)
you assign tasks to operators in RFOT (RF Operator Task Assign)
you wish to track the equipment used by each RF operator and restrict certain RF operators to certain
activity types and equipment types
you perform task interleaving in RFITLV (RF Interleaving)
RF operators must be set up in OPER (Operator Code) before they can be set up in RFOP.
FIELD DESCRIPTIONS
Operator Mandatory
(defined in OPER)
RF GUIDE 4.0.1* 79
GENERAL SETUP PROGRAMS
RF Operator (RFOP)
FIELD DESCRIPTIONS
The company in which the RF operator will work. If you use Vocollect Voice
and the operator has to switch companies, you must manually change the
operator’s company in RFOP. If you pick your orders in RFPIC, you do not
need to manually change the operator’s company in RFOP as the operator
can perform this task in RFPIC.
MHET Types Exclusions See “RF Operator (RFOP)” on page 408 for further information.
Activity Type Exclusions See “RF Operator (RFOP)” on page 408 for further information.
1 Enter RFOP.
2 Click on Create.
3 Key in your operator code and press Enter or press F10 to select it from the pick list.
4 Key in the operator’s default company and press Enter or press F10 to select if from the pick list.
5 If required, key in the operator’s voice password and press Enter.
6 In the Task Profile Block, key in your task profile and press Enter or select it from the pick list.
7 Repeat the above step for each additional task profile that you wish to assign to the operator.
80 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Extra Charge Setup for RF
1 Log on to ActiveDesktop and proceed to change your password. Once your new password is accepted,
you can log on to a RF device using this password.
You can add extra charges to a receipt or order in RF using the program RFEC (RF Extra Charge). You can
also enter extra charges directly in RFPIC (for outbound orders) and in RFCH (for inbound receipts). You
activate extra charge entry in RF by making the appropriate changes to your extra charge profile in ECHP
(Extra Charge Profile).
Extra charge entry in RF is only available for customer-based extra charges; that is your ECHP profile is
attached to a customer. AccellosOne 3PL does not support RF extra charges attached to an item.
F I E L D D E S C R I P T I O N S ( E CH P )
Charge Code (CHAR) The charge code that you enter must be unique in ECHP within a given
inbound or outbound workflow. You cannot use the same charge code under a
different sequence for a given inbound or outbound workflow.
RF GUIDE 4.0.1* 81
GENERAL SETUP PROGRAMS
Extra Charge Setup for RF
F I E L D D E S C R I P T I O N S ( E CH P )
Allow RF Entry / Allow There are three possible scenarios for these two fields:
Override of Charge
Quantity in RF Allow RF Entry = No
Allow Override of Charge Quantity in RF = No
In this scenario, the RF operator cannot add extra charges in RF.
Allow RF Entry = No
Allow Override of Charge Quantity in RF = Yes
In this scenario, the RF operator can select one or more extra charges from a
predefined list and can enter any charge quantity for the selected charge(s).
If you enter a flow, the extra charge can only be added at this inbound or out-
bound flow. If you leave this field blank, the extra charge can be added at any
inbound or outbound flow.
Other fields Refer to the Billing and Invoicing Guide for further information.
82 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Extra Charge Setup for RF
For inbound extra charges, you must set the Extra Charge Entry Type flag on the RFCH Only 2 tab in MRFP
to the appropriate value.
F I E L D D E S C R I P T I O N S ( R F C H O NLY 2 )
Extra Charge Entry Type Allow Extra Charge Entry When Completed
Allow Extra Charge Entry When Exiting
If you select “Allow Extra Charge Entry When Completed”, the extra charge
screen will display when you finish checking/unloading the receipt line. If you
select “Allow Extra Charge Entry When Exiting”, the extra charge screen will
display when you exit RFCH.
RF GUIDE 4.0.1* 83
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
For outbound extra charges, you must set the Extra Charge Entry Type flag on the RFPIC tab in MRFP to the
appropriate value.
Extra Charge Entry Type Allow Extra Charge Entry When Completed
Allow Extra Charge Entry When Exiting
If you select “Allow Extra Charge Entry When Completed”, the extra charge
screen will display when you finish picking the order line. If you select “Allow
Extra Charge Entry When Exiting”, the extra charge screen will display when
you exit RFPIC.
In this program, you subdivide your warehouse into separate zones. Each zone can be considered a separate
work area and the same order or receipt can be assigned to multiple RF operators working in different zones.
A zone can be a section of your warehouse or a set of racks (for example, all floor-level racks could be zone
1, all second-level racks could be zone 2, etc.).
There are seven zone types in WHZO:
Directed Put-Away Directed put-away zones allow you to define overflow sequences for directed
put-away in the Overflow Sequence Block. For example, if no locations are
available in put-away zone 1, try put-away zone 2 then put-away zone 3.
General General zones have no collection or drop off points assigned to them.
Sorting Area Sorting Area zones types have a drop off point assigned to them; that is, they
require a location code in the header block of WHZO.
Material Handling Type This zone type is used for material handling type integration.
P&D P & D zones types have a collection point assigned to them; that is, they
require a location code in the header block of WHZO.
84 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
HEADER BLOCK
In this block, you define your warehouse zone code and description, your zone type code and your
warehouse/location code for sorting or P & D zones types.
FIELD DESCRIPTIONS
Description Mandatory
Labor Standard Modifier See the section on Operational Board in the Operations 2 Guide.
RF GUIDE 4.0.1* 85
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
FIELD DESCRIPTIONS
The zone type field allows you to define collection and drop off points for a
zone and to assign to it a specific material handling equipment type.
If you select General, the zone will have no collection or drop off points. If you
select Sorting Area, the zone will have a collection point for outbound product.
If you select P & D, the zone will have a drop off or pick-up point for product.
Task Required Only available if Enable Task Interleaving in COMP = Create Tasks According
to Zone Setting
The warehouse code of the location that you wish to attach to the zone.
The sorting or P & D location that you wish to attach to the zone.
FORMULA BLOCK
The Formula Block appears in Create Record mode only. It allows you to specify warehouse and location
restrictions (for example, a range of locations) for the zone. When you exit the Formula Block, the system will
automatically add the locations that you specify to the zone.
86 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
If your location codes contain spaces or hyphens (-), you must use the caret character (^) before the space or
hyphen.
EXAMPLE 1
EXAMPLE 2
FIELD DESCRIPTIONS
I = Inbound
O = Outbound
B = Both
If you specify Inbound, the locations added by the system will all be flagged as
inbound locations. If you specify Outbound, the locations added by the system
will all be flagged as outbound locations. If you specify Both, the locations
added by the system will all be flagged as both inbound and outbound loca-
tions.
If you are setting up a P, S or M zone type, the value that you enter in this field
is ignored because the zone type is either self-defined or defined in other pro-
grams.
Only locations belonging to the warehouse(s) that you specify can be added to
the zone. See the following paragraph for a list of the operands that you use to
specify one or more warehouses.
Your location restrictions for the zone. See the following paragraph for a list of
the operands that you use to specify one or more locations.
RF GUIDE 4.0.1* 87
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
The following operands can be entered in the Warehouse Code and Location Code fields:
- from X to Y (a range)
EXAMPLES
88 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
PROCEDURE
1 Enter WHZO.
2 Click on Create Record.
3 Key in your zone code and press Enter.
4 Key in your description for the zone code and press Enter.
5 Key in 1 as your zone sort value and press Enter.
6 Press Enter to bypass the Labor Standard Modifier field.
7 Press Enter to bypass the Communication Reference field.
8 In the Zone Type Code field, key in the appropriate value (G for General, I for Interleaving, S for Sorting
Area, P for P & D or I for Interleaving) and press Enter.
RF GUIDE 4.0.1* 89
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
a) Key in I for Inbound, O for Out- a) Key in B for Both in the Inbound/
bound or B for Both in the Outbound field and press Enter.
Inbound/Outbound field and
press Enter.
11 In the Warehouse Code field, key in your warehouse code restriction (for example, “=”) and press Enter.
12 In the Location Code field, key in your location restrictions (for example, “>”) and press Enter. Accel-
losOne 3PL will retrieve all locations that meet the criteria that you specify and display the Locations
Block. If there are no location restrictions, leave this field blank.
13 If you wish to print, fax or e-mail your External Messages, click on Select Printer. Then key in the appro-
priate printer code or use the pick list function to select it. Next click on Execute Report. If you selected
either fax or mail as your printer, the Fax/Mail Entry pop-up window will appear. Enter your fax number or
e-mail address and any other required information and then click on Send e-mail or Send fax.
90 4.0.1* RF GUIDE
GENERAL SETUP PROGRAMS
Warehouse Zones (WHZO)
14 Click on Exit to close the External Messages window. The locations that you specified in the Formula
Block will be added to your zone.
15 Click on Location Block.
16 If required, you can manually add or remove a location in the Location Block. To add a location, click on
Create Record and key in your warehouse code, your location code, your inbound/outbound value and
your zone type.
If you wish to remove a location from the Location Block, move your arrow key to the appropriate location
and press Enter until your cursor is positioned in the Inbound/Outbound column. Then click on Delete.
If you wish to change the Inbound/Outbound flag, key over the default value of B for Both with either I for
Inbound or O for Outbound.
When you finish making your changes, click on Return to Main.
17 When you finish setting up your zone, click on Master Block and then Exit to exit.
RF GUIDE 4.0.1* 91
GENERAL SETUP PROGRAMS
RF Supervisors
RF Supervisors
RF supervisors have certain privileges that are denied to non-supervisory RF operators; for example, they
can zero out receipts lines in RFCH when a variance is encountered. See the System Administration Guide
for further information on setting up an RF supervisor.
92 4.0.1* RF GUIDE
OUTBOUND SETUP PROGRAMS
Overview ............................................................................................................ 94
Customer Codes (CUST) .................................................................................. 94
Customer / Consignee Document Setup (CCDU)........................................... 96
Item Hazardous Material Violation (IHZV) ....................................................... 97
Outbound Pallet Building ................................................................................. 98
Task Profile (REGI).......................................................................................... 101
Item Consignee Configuration (ICOC)........................................................... 106
Outbound Process Configuration (CCCC).................................................... 107
Warehouse Customer Consignee OPID Rule (WCCO) ................................ 110
Customer/Consignee Outbound Rules (CCOR) ........................................... 111
RF GUIDE 4.0.1* 93
OUTBOUND SETUP PROGRAMS
Overview
Overview
The following graphic shows the various setup programs for outbound processing.
RFOP
CCDU
CTSZ ICNP
Make sure that the Consolidation Method for Allocated Lines field in CUST is set to Multiple Location Lines
NOT Allowed.
94 4.0.1* RF GUIDE
OUTBOUND SETUP PROGRAMS
Customer Codes (CUST)
FIELD DESCRIPTIONS
If you set this field to Multiple Location Lines Allowed, AccellosOne 3PL will
not create additional order lines when an order line picks from more than one
location. If you set this field to Multiple Location Lines NOT Allowed, Accel-
losOne 3PL will create additional order lines to ensure that no order line has
more than one location line.
For example, if an order line of 30 cases requires picks from three different
locations, AccellosOne 3PL will create two additional order lines for a total of
three: line 1 (10 cases), line 2 (15 cases) and line 3 (5 cases).
The Multiple Location Lines NOT Allowed option requires P-type order lines in
ENOR.
The advantage of this feature is faster picking of large order lines by splitting
the work into multiple tasks that can be performed by multiple operators. If you
activate this feature, three operators could work on the same order line if that
line picked from three different locations. If you deactivate this feature, the
entire order line could only be picked by a single operator.
CUST (Customer Code) screen showing Consolidation Method for Allocated Lines set to Multiple
Location Lines NOT Allowed
RF GUIDE 4.0.1* 95
OUTBOUND SETUP PROGRAMS
Customer / Consignee Document Setup (CCDU)
In this program, you set up your label document(s) and pick methods for RFPIC, RFPK and RFSC.
Documents set up in CCDU are not flow dependent and do not need to be attached to the appropriate
outbound flow in DIFP.
You can set up a single label document for all customers/carriers/consignees or you can define a specific
label document for certain customer/carrier/consignee combinations. For example, in RFPIC label 1 will print
for customer A, label 2 will print for customer B and label 3 will print for all other customers.
You can also define different documents for different pick methods: for example, print label 1 when each
picking and print label 2 when pallet picking.
FIELD DESCRIPTIONS
Customer Code The customer that the label document applies to or .ALL for all customers.
Consignee Code The consignee that the label document applies to or .ALL for all consignees.
Carrier Code The carrier that the label document applies to or .ALL for all carriers.
The pick method that the label document applies to. If you leave this field
blank (that is, no pick method), the pick method is CASE.
Document Code Your document code for the unique customer/consignee combination. This
document code must be set up in DOCU.
Interface Flag If you are printing an actual document on a physical printer, leave this flag
blank. If you are sending your CCDU information to another device for further
processing, click on this flag to select it.
96 4.0.1* RF GUIDE
OUTBOUND SETUP PROGRAMS
Item Hazardous Material Violation (IHZV)
CCDU screen showing bill of lading document for customer A2, all carriers, all consignees and all
picking methods
In this program, you define your segregation rules for outbound pallets and containers; for example,
hazardous class 1.1 (Explosives) cannot be mixed with hazardous class 1.2 (Explosives). The segregation
rules apply to RFPIC (RF Pick) and RFMG (RF Merge OPID). To activate hazmat segregations rules in these
programs, you must set the Separate Hazmat by Item in Each Pick flag in MRFP (RFPIC 3 tab) to Yes.
If the rules in IHZV are violated, the RF operator will be not be able to pick the line in RFPIC or merge the
OPID in RFMG.
IHZV screen showing classes 1.2, 1.3 and 1.4 as restricted classes for class 1.1
RF GUIDE 4.0.1* 97
OUTBOUND SETUP PROGRAMS
Outbound Pallet Building
The Pallet Build engine allows you to generate picking assignments (outbound pallets) based on predefined
pallet building rules. The built pallets are stored in the database, allowing you to view and evaluate pending
work in either Pulse or d'Amigo. Pallet building is only available for orders assigned to a wave in Wave
Manager and picked in RFITLV (RF Interleaving).
The Pallet Build engine will automatically generate pallet build assignments based on the following rules:
all cartons must be on the same order
the maximum cube for full pallet/half pallet (REGI) cannot be exceeded
the maximum weight (REGI) cannot be exceeded
“like” product (that is, the same alternate reporting type/code) will be kept together (ITEM)
the pallet build restrictions defined in IPBR must be respected
There are four setup programs for the Pallet Build engine:
IPBR (Item Pallet Build Restrictions)
ITEM (Item Codes)
REGI (Task Profile)
CONS (Consignees)
In IPBR you set up your pallet build restrictions, defining which items can be placed together on the same
pallet. For example, if you add the code R1 in the Header Block and the code R2 in the Detail Block, items
assigned your R1 pallet restriction code can never be placed on the same pallet as items assigned your R2
pallet restriction code.
If you select the Allow Only on Top checkbox, items assigned the pallet build restriction code in the Detail
Block can be placed on top of but not underneath items assigned the pallet build restriction code in the
Header Block. Your IPBR code is then attached to the appropriate items in ITEM.
IPBR screen
98 4.0.1* RF GUIDE
OUTBOUND SETUP PROGRAMS
Outbound Pallet Building
RF GUIDE 4.0.1* 99
OUTBOUND SETUP PROGRAMS
Outbound Pallet Building
ITEM screen
In REGI you define the following: Alternate Reporting Type/Alternate Reporting Code, Maximum Pallet Height
and Maximum Number of Cartons.
REGI screen
In CONS, you set the Single Item Per Outbound Pallet flag to the appropriate value. If you set this flag to
Yes, the Pallet Build engine will check this flag and restrict outbound pallets to a single item.
In this program, you set up your task profile. A task profile defines various picking options for RF operators.
For each task profile that you set up, you can define the following options:
the default staging location and warehouse
the picking path mode or sequence in which locations are picked
the sort sequence code (if any) and picking path mode
the alternate reporting type/code for a pallet assignment
the maximum pallet weight and/or cube for a pallet assignment when that pallet assignment contains
mixed product
REGI is a mandatory setup program for the following programs/functions:
voice-activated picking
outbound pallet building
picking by assignment in RFPV
task interleaving in RFITLV
If you pick by order line in RFPIC and do not use assignments, task profiles are not required.
Task profilers are attached to operators in RFOP. They can also be attached to Outbound Process Configu-
ration (CCCC). If required, you can set up different task profilers for different combinations of customer,
consignee and carrier in CCCC.
FIELD DESCRIPTIONS
Description Mandatory
The default staging location for the task profile. If you do not specify a default
staging location, the RF operator will be required to specify a staging location
during picking.
Warehouse Optional
The sort sequence or “snaking” of your locations within the task profile. This
sort sequence is applied to a picking path mode. If you do not enter a sort
sequence code, the sequence of your pick locations will be based on the
option that you select in the Picking Path Mode field.
FIELD DESCRIPTIONS
Picking Path Mode Cartons for one item all on one pallet
With this option, work assignments will be sequenced in item code order. That
is, the first item on the order will be picked first followed by any other order
lines containing that item. Only after the first item is fully picked will Accel-
losOne 3PL start picking the second item.
This option ignores any weight and cube limits that you define for a pallet.
Once the RF operator starts picking an item, all product goes on the current
pallet regardless.
If the first item is fully picked and there is room on the pallet, the second item
will be picked and placed on the same pallet.
NOTE This picking path mode will lead to more pallets containing a single
item only, but at the cost of more travel time because of skipped locations.
AccellosOne 3PL will sequence your work assignments as follows: line 1, line
2, line 4 and line 3. That is, line 4 will be picked before line 3 because adding
line 3 to lines 1 and 2 would lead to a split order line, while adding line 4 to
lines 1 and 2 would not.
In these two fields, you define “like” items for the Pallet Build engine. If you
populate these fields with an alternate reporting type/code, only product with
the same alternate reporting type/code can be placed on the same pallet.
FIELD DESCRIPTIONS
The maximum weight for a full pallet. If the weight of the order line exceeds
this maximum, AccellosOne 3PL will split the line into two or more work
assignments.
Weight Measure Code The weight measure code for the Maximum Pallet Weight field.
The maximum cube for a full pallet. If the cube of the order line exceeds this
maximum, AccellosOne 3PL will split the line into two or more assignments.
Max. Number of Cartons The maximum size of a pallet assignment for the Pallet Build engine.
Linear Measure Code The linear measure code for the Maximum Pallet Cube field.
Maximum Pallet Height The maximum height for a full pallet. If the height of the order line exceeds this
maximum, AccellosOne 3PL will split the line into two or more assignments.
Max. Number of Opera- In this field, you define “congestion” in a warehouse aisle for interleaving pur-
tors poses; that is, if the number of operators in a task profile exceeds this number,
the extra operators will not be assigned any tasks until one or more existing
operators completes his or her task(s).
1 Enter REGI.
REGI screen
9 When you finish setting up the general parameters for your task profile, click on Save .
In this program, you can define the outbound pallet quantity by consignee when building outbound pallets
(pallet build, case picking, OPID merge) for an outbound order. ICOC must be activated in CCOR by setting
the Use Consignee Item Configuration flag to Yes for the appropriate consignee record.
ICOC screen
In this program, you set up your pallet wrapping rules for different customer/carrier/consignee combinations.
You can also override certain MRFP settings for a specific customer/carrier/consignee combination. For
example, suppose your default picking mode is set to case picking in MRFP; however, based on your CCCC
setting for a specific customer/carrier/ consignee combination, you can establish normal mode picking instead
of case pick for that combination.
FIELD DESCRIPTIONS
Customer Code The customer that the outbound process configuration applies to or .ALL for
all customers.
Carrier Code The carrier that the outbound process configuration applies to or .ALL for all
carriers.
Consignee Code The consignee that the outbound process configuration applies to or .ALL for
all consignees.
If pallet wrapping is required for a pallet being built in the warehouse, enter the
number of times in this field.
Task Profile Code (REGI) The outbound process configuration’s task profile.
FIELD DESCRIPTIONS
If you select a mode in this field, it will override your default picking mode in
MRFP.
No Restriction
Per Item
Per OPID, OPID entered by user, QRS label by line
Per Order
Per Order Line
Per Order Line in NM Mode
In this field, you define your OPID assignment rules for case pick mode in
RFPIC.
If you select Per Item, a single OPID per item is required. That is to say, the
same item cannot be assigned to two or more OPID’s. If you select Per Order,
a single OPID per order is required. If you select Per Order Line, a single
OPID per order line in case pick mode is required. If you select Per Order Line
in NM Mode, a single OPID per order line in normal mode is required.
If you select Per OPID, OPID entered by user, QRS label by line, AccellosOne
3PL will generate a QRS value for each OPID entered by the user. This option
is only available for QRS orders in which the user enters an OPID for each
order line.
If you select No Restriction, the same OPID can be assigned to any number of
items, orders or order lines.
If you select an option in this field, it will override the option that you selected
in MRFP.
Workflow Profile Code If you enter a workflow profile code in this field, it will override the workflow
(DIFP) profile code(s) attached to the customer and consignee.
FIELD DESCRIPTIONS
if you select Current Date, AccellosOne Ship will use the current date as the
ship to date sent to the parcel carrier even if that date differs from the order
ship to date in AccellosOne 3PL. If you select Ship to Date, AccellosOne Ship
will use the order ship to date in AccellosOne 3PL as the ship to date sent to
the parcel carrier.
Maximum Gross Weight The maximum gross weight for an OPID in RFPIC/RFMG (that is, pallet build-
per OPID ing, case picking and OPID merging).
Maximum Net Weight per The maximum gross weight for an OPID in RFPIC/RFMG (that is, pallet build-
OPID ing, case picking and OPID merging).
OPID Weight Measure The unit of measure for the maximum weight.
Code
OPID Alert Percentage The percentage of the maximum weight at which an alert will be generated for
the RF operator in RFPIC. If the operator selects Yes at the Continue? prompt,
he or she can pick the selected line even though it is overweight.
CCCC screen
In this program, you define your mix/no mix OPID rules for each warehouse/customer/consignee combi-
nation. The Allow Mixing Items in OPID flag in WCCO overrides your OPID Assignment Rules in CCCC. It
also overrides your Single Item Per Outbound Pallet setting in CONS. Mix/no mix OPID rules apply to the
programs RFPIC, RFPK, RFITLV and RFMG.
NOTE: If an order requires the generation of a SSCC label, item codes cannot be mixed.
WCCO screen
In this program, you define your product mixing rules for case picking, pallet building and OPID merging as
well as your SSCC/MCP label requirements.
FIELD DESCRIPTIONS
If you set this flag to Yes, allocation will only allocate product whose expiry
date is greater than or equal to previously shipped inventory from that cus-
tomer to that consignee.
FIELD DESCRIPTIONS
If you select 1, mixing of inventory at all levels will be allowed. If you select 2,
mixing of inventory up to level 2 will be allowed. If you select 3, mixing of
inventory up to level 3 will be allowed. If you select 4, no mixing of inventory at
any level will be allowed.
If you enter a minimum number of shelf life days in this field (say, 10), all prod-
uct on the same pallet must have a shelf life of at least 10 days.
If you enter a maximum number of shelf life days in this field (say, 20), all
product on the same pallet must have a shelf life of greater than 20 days.
Number of Days Between Only available if OPID Expiry Date Optimization Type = 2
Min./Max. Dates
In this field, you specify the maximum number of days between your minimum
number of shelf life days and your maximum number of shelf life days. If there
is a conflict between this value and your minimum/maximum number of shelf
life days value, the more restrictive condition will apply.
FIELD DESCRIPTIONS
Number of Days Between Only available if OPID Expiry Date Optimization Type = 3
Multiple Expiry Dates in
OPID
If you enter a number in this field (say, 90), any product with an expiry date
greater than 90 days can be mixed.
If you set this flag to Yes, you can define outbound pallet quantity by con-
signee in ICOC. If you set this flag to No, outbound pallet quantity by con-
signee in ICOC is deactivated.
If you set this flag to Yes, an SSCC label will be generated. If you set this flag
to No, no SSCC label will be generated. This field overrides the Generate
UCC-128 Sequence Number flag in CONS (Consignees).
Y = Yes
N = No
If you set this flag to Yes, the following requirements must be met:
the SSCC number is received via EDI
it is assigned to an LPN
a full pallet is picked
If you set this flag to No, the SSCC label will be generated by AccellosOne
3PL.
FIELD DESCRIPTIONS
If you set this flag to Yes, the customer name will print on the e label. If you set
this flag to No, the customer name will not print on the label.
If you set this flag to Yes, OPID’s will be restricted to product belonging to a
single order. If you set this flag to No, an OPID can contain product from multi-
ple orders.
The option that you select in this field overrides the option that you select in
the OPID Assignment Rules field in CCCC.
If you select Yes, an MCP label is required. If you select No, an MCP label is
not required.
Accessing RF
You access RF through an RF device. To access RF through an RF device, log onto Tera Term or some other
terminal emulation software.
The company that you are currently working in is displayed on the RF Main Menu. If you wish to change this
company, you key in your new company code and press Enter.
current company
RF Main Menu
2 Check the company code in the top left-hand side of your screen.
3 If you wish to change companies, key in your new company code and press Enter.
4 Proceed to enter the RF program that you wish to use.
You look up your inventory in RFIT. For the item or items that you specify, RFIT shows the level 2, 3 and 4
values, whether the item is on hold, the location in which the item is stored and the on-hand, on-order, on-
receipt and available quantities.
You can enter up to six search criteria for any given query. For example, you can specify your customer code
only and RFIT will show all product belonging to that customer. If you enter your customer code and item
code, RFIT will show all product for the item that you specify. If you enter customer code, item code and level
2 value, RFIT will show all product for the level 2 value that you specify.
If you enter no search criteria, RFIT will show all product in your warehouse regardless of customer.
NOTE You can only look up records in RFIT that have positive inventory. If you
wish to look up inventory with zero balances, you must use LOEN (Look Up Inven-
tory).
FUNCTION KEYS
Criteria Mode
Main Mode
1 Enter RFIT.
RF — Item Look-Up
2 Enter or scan in the appropriate search criteria. You can query by one or more of the parameters shown
below. If you do not want to enter a parameter (for example, you want to look up all items regardless of
level 2 and 3 values), press Enter to bypass the appropriate fields. You can query by one or more of the
following:
customer code
item code
hold code
3 When you finish entering your search criteria, press F2 to execute your query.
1 = current record
displayed
3 = number of
records that met the
criteria that you
specified
4 If your query resulted in multiple records being retrieved from the database, use your arrow keys to scroll
forward and backward through the records that matched the criteria that you specified.
5 Press F1 to perform another query or press F4 to exit.
You can look up inventory by either item or by location in RFPR. For each item or location that you specify,
RFPR shows the level 2, 3 and 4 values, whether the item is on hold, the location in which the item is stored
and the available, on hand, on order and replenishment quantities.
There are two types of searches that you can do in RFPR: you can search for all inventory records including
plus records or you can exclude plus records from your search results. A plus record is a temporary record
generated by the system when you allocate an order for a reserve logic customer. The inventory levels that
are unknown at the time of allocation are indicated by a plus sign.
If you query by location code and warehouse, the search results are sorted in customer code and levels 1/2/
3/4 sequence. If you query by any other criteria, the search results are sorted in location code, inventory
access code sequence.
FUNCTION KEYS
All Modes
FUNCTION KEYS
1 Enter RFPR.
2 Enter or scan in the appropriate search criteria. You can query by one or more of the following:
customer code
item code
level 2 and 3 value
location and warehouse code
hold code
3 When you finish entering your search criteria, do one of the following:
RFPR screen (record 40) showing available, on-hand, on order and replenishment quantities for loca-
tion A103
The AV.Q field shows the available quantity, the OH.Q field shows the on-hand quantity, the ORD field
shows the on order quantity and the REPI field shows the replenishment quantity.
4 If your query resulted in multiple records being retrieved from the database, use your arrow keys to scroll
forward and backward through the records that matched the criteria that you specified.
5 Press F1 to perform another query or press F4 to exit.
You look up your allocated unconfirmed receipts in RFIL. If the receipt is confirmed or unallocated, you cannot
look it up in RFIL. There are three options in RFIL:
you can look up all allocated lines on an unconfirmed receipt
you can look up all lines that have been staged but not put-away (if you do not stage your product, this
option is not available)
you can look up all lines that have been put-away
RFIL shows the quantity of each receipt line in the lowest SKU. For example, if your receipt line has a quantity
of two pallets and there 60 cases to a pallet, the quantity in RFIL will read 120.
FUNCTION KEYS
Results Mode
FUNCTION KEYS
Main Mode
1 Enter RFIL.
1 = current line
displayed
5 = total number
of lines on receipt
4 Use your arrow keys to scroll forward and backward to view each receipt line.
5 If you stage your product before you put it away, press F2 (Receiving) to view product that has been
staged but not put-away.
6 If you have multiple lines of staged product, use your arrow keys to scroll forward and backward to view
each line.
7 Press F3 (Put-Away) to view product that has been put-away.
RFIL screen showing three lines of product that have been put away
8 If you have multiple lines of product that have been put-away, use your arrow keys to scroll forward and
backward to view each line.
9 When you finish looking up your receipt, press F4 the required number of times to exit.
You look up your allocated unconfirmed order lines in RFOL. If the order line is confirmed, you cannot look it
up in RFOL. For each order line that you look up, RFOL shows the order number, customer code, line
number, warehouse code, location type, up to four inventory levels, hold code (if any), quantity, location and
OPID (if any). Locations with a quantity of zero are not shown.
There are three options in RFOL:
you can look up all unconfirmed order lines (that is, the order is either allocated or picked)
you can look up unconfirmed order lines that have been allocated but not picked
you can look up unconfirmed order lines that have been picked
NOTE The allocated and picked options in RFOL always show the allocated and
picked lines for the currently selected order. If you wish to look up all allocated or
picked lines regardless of order, you must start a new query. You cannot query on all
allocated or picked lines if there is an order displayed on your screen.
Order line records in RFOL are sorted by order number followed by location code.
FUNCTION KEYS
Results Mode
Main Mode
1 Enter RFOL.
2 Enter or scan in the appropriate search criteria. You can query by one or more of the parameters shown
below. If you do not want to enter a parameter (for example, you want to look up all orders regardless of
warehouse), press Enter to bypass the field.
order number
warehouse code
location type code
3 After pressing Enter in the Location Type field, press F1 (All) to display the first order line on the first
order.
1 = current record
displayed
133 = total num-
ber of order lines
for all uncon-
firmed orders
Order Line Look-Up showing ALL option
4 Use your arrow keys to scroll forward and backward to view each order line on each unconfirmed order.
5 Press F2 (Allocated) to view the order lines for the currently selected order that have been allocated.
6 Use your arrow keys to scroll forward and backward to view each order line that has been allocated.
7 Press F3 (Picked) to view the order lines of the currently selected order that have been picked.
8 When you finish viewing your orders, press F4 the required number of times to exit.
This program allows you to look up inventory information by scanning in a serial number from a bar code
label. For each serial number, RFLOIP shows the customer code, up to four inventory levels, the warehouse
and location, and the on-hand and available quantities. You can scan in the entire bar code label or you can
manually key only the serial number portion of the bar code.
You cannot look up serial numbers if the product is on a confirmed order.
FUNCTION KEYS
Criteria Mode
Main Mode
1 Enter RFLOIP.
RF — Look Up Item Process showing inventory information for serial number 0001
3 If your query resulted in multiple records being retrieved from the database, use your arrow keys to scroll
forward and backward through the records that matched the criteria that you specified.
4 Press F1 to perform another query or press F4 to exit.
This RF look-up program is similar to the non-RF program LOLO (Look Up Location Information). It is
designed to be viewed on a truck-mounted RF device with a wider screen and allows warehouse personnel
full access to AccellosOne 3PL’s location information.
Refer to the Operations 1 Guide for detailed information on LOLO.
1 Enter LOLORF.
RF - Look Up Location
RF - Look Up Location
4 When you finish looking up; your location, press F4 (Location) and then F4 (Exit).
This RF look-up program is similar to the non-RF program LOEN (Look Up Entity Information). It is designed
to be viewed on a truck-mounted RF device with a wider screen and allows warehouse personnel full access
to AccellosOne 3PL’s location information.
Refer to the Operations 1 Guide for detailed information on LOEN.
1 Enter LOENRF.
4 When you finish looking up your inventory, press F4 (Inventory) and then F4 (Exit).
This RF look-up program is similar to the non-RF program LORE (Look Up Receipts). It is designed to be
viewed on a truck-mounted RF device with a wider screen and allows warehouse personnel full access to
AccellosOne 3PL’s receipt information.
Refer to the Operations 1 Guide for detailed information on LORE.
1 Enter LORERF.
RF - Look Up Receipts
RF - Look Up Receipts
4 When you finish looking up your receipts, press F4 (Receipt Block) and then F4 (Exit).
This RF look-up program is similar to the non-RF program LOOR (Look Up Orders). It is designed to be
viewed on a truck-mounted RF device with a wider screen and allows warehouse personnel full access to
AccellosOne 3PL’s order information.
Refer to the Operations 1 Guide for detailed information on LOOR.
1 Enter LOORRF.
RF - Look Up Orders
RF - Look Up Orders
4 When you finish looking up orders, press F4 (Order Block) and then F4 (Exit).
You look up inventory by location for reserve logic customers in RFLR. For each location that you specify,
RFLR shows the on-hand, on order replenishment and available quantities at the inventory level that the
customer reserves at. For example, if a three-level customer reserves at level 2 (lot number), RFLR will show
quantities for each unique lot in a given location.
Locations in which the available quantity is less than or equal to zero are not shown and inventory on hold is
not included in the location quantities.
If your query retrieves multiple locations, locations are sorted by the expiry date of product in the location.
FUNCTION KEYS
Criteria Mode
Main Mode
FUNCTION KEYS
1 Enter RFLR.
2 Key in your level 1 value and press Enter. If two customers have the same item code, a pick list will dis-
play. Use your arrow keys to position the cursor over the item code that you wish to look up and press
Enter to select it.
3 If required, key in your level 2 value and press Enter.
4 If you have four inventory levels and reserve at level 3, you can key in a level 3 value and press Enter.
5 If required, key in your location code and press Enter.
6 If required, key in your warehouse code and press Enter.
7 When you finish entering your search criteria, press F2 (Qu) to query.
RF — Look Up Reserve Logic Customer showing level 2 quantities for location S100
8 If your query retrieves multiple locations, use your arrow keys to scroll through the list of locations.
9 When you finish looking up your reserve logic inventory by location, press F4 twice to exit.
Overview of Put-Away
1 OFFICE
ENRE You enter the receipt in ENRE (Enter,
Modify and Delete Receipt).
2 OFFICE
CHRF You advance the receipt's flow to DRDO
(driver arrived at door) in CHRF (Time-
Stamp and Confirm Receipt).
3 WAREHOUSE
RFCH You unload the receipt in RFCH (RF
Check/Unload).
4 WAREHOUSE
One-step put- If you are performing one-step put-away,
No Yes
away? you put away the product in a final non-
staging location. If you are performing two-
step put-away, you put away the product in
a staging location.
RFPU
If you are performing two-step put-away,
you put away the product in RFPU (RF Put-
Away).
5 OFFICE
CHRF
You confirm the receipt in CHRF (Time-
Stamp and Confirm Receipt).
In non-RF receiving, you time-stamp and advance the flow of a receipt in CHRF (Time-Stamp and Confirm
Receipts). Advancing the flow of a receipt in CHRF advances the flow of all receipt lines and receipt location
lines on the receipt. You cannot advance the flow of one receipt line and leave another receipt line remain at
its original flow.
In RF receiving, on the other hand, AccellosOne 3PL automatically advances the flow of individual receipt
lines and receipt location lines. For example, when you unload product in RFCH, the receipt line’s flow is
automatically advanced from STUN (Start Unloading) to INST (Inbound Staged). Because the flow of
individual receipt lines is advanced as each receipt line is unloaded, not all lines on a given receipt will be at
the same flow. When this happens, the receipt header will show the earliest flow on the receipt.
For example, suppose there are five receipt lines on a given receipt: two lines are at the flow STUN, two lines
are at the flow INST and one line is at the flow STPU (Start Put-Away). If you look up the receipt in LORE, the
receipt’s flow will be set to STUN, which is the earliest flow.
The unique identifier (UI) is a single value that represents an inventory entity defined down to the lowest
inventory level. For example, the UI value of ABC001 could represent item A1, lot 101, pallet ID 10 belonging
to customer A.
Unique Identifiers make it possible to enter a single value in the core RF program such as RFCH, RFPU,
RFRL, RFRP and RFPIC that identifies the product that you are working with. When you enter this value,
AccellosOne 3PL automatically populates the customer code and inventory level fields with the correct
values.
AccellosOne 3PL can automatically generate these values when you receive inventory in ENRE or you can
manually create the values yourself.
RFCH screen showing UI value of GN000286 that identifies three inventory levels
NOTE Depending on how you track your customers’ inventory, the unique identifier
may or may not be unique across customers. For example, suppose you have two
customers: customer A whose inventory is tracked by item code/lot number/pallet ID
and customer B whose inventory is tracked by item code and lot number. Customer A
could have “001” as the unique identifier representing a particular pallet ID and cus-
tomer B could have “001” as the unique identifier representing a particular lot number.
When this happens, if both inventory entities are on open receipts at the appropriate
flow, entering “001” in the UI field of RFCH will result in pick list from which the RF
operator must select the appropriate inventory.
In this program, you unload your receipt and place it either in a staging location (if you are going to perform
final put-away in RFPU) or in a non-staging location (if you are performing one-step put-away with no
processing in RFPU). Your receipt must be at the flow DRDO (Driver Arrived) before you can unload it. If the
product that you are receiving is not on the original receipt, you can create a new line for the product in
RFCH.
RFCH supports two types of receipt lines:
P type in which AccellosOne 3PL generates your pallet ID or you enter your pallet ID’s manually during
receipt entry in ENRE (for the purposes of RF, P type includes the following line types in ENRE: I for In-
Transit, H for Handling Only and S for Storage Only)
U type in which inventory level 2 or higher is unknown at the time of receipt entry (also known as blind
receiving)
With P-type lines (that is, all inventory levels have been entered in ENRE), you can enter your lowest
inventory level and RFCH will retrieve the receipt number and all other inventory levels. With U-type lines
(that is, one or more inventory levels have not been entered in ENRE), you must enter your receipt number
and all inventory levels.
CAUTION RFCH does not support multiple operators working on the same receipt
when these operators are working in different modes. If you allow multiple operators
to work on the same receipt, make sure that all operators are working in the same
mode — either unload mode or put-away mode.
PROCESS VAL- If you wish to scan in a catch weight and serial number, you require two process
UES values: one for catch weights and one for serial numbers. These codes must be
set up in IPRO (Item Process) with the Create Automatic Records flag set to Y for
Yes and then attached to a profile in IPRP (Item Process Profile). The IPRP pro-
file must in turn be attached to the item(s) requiring the process values.
See the section “Item Process Values” in the Operations 2 Guide for further infor-
mation about process values.
SCAN PARAME- Only required if you are scanning process values, inventory levels or UI values
TER CODE from a bar code label
You need a scan parameter profile defined in SCPR (Scan Parameter Code).
This profile must contain a minimum of two records in the Detail Block: one record
for your scanned in weight and another record for your scanned in serial number.
The SCPR profile must in turn be attached to the item requiring the process val-
ues.
BAR CODE PRO- Only required if you are scanning a UI value or inventory levels from a bar code
FILE label
You must define a bar code profile in BAPR and attach to it the scan parameter
code that you set up in SCPR.
DOCUMENTS The Print Document Without Assigning Locations flag in DOCU (Documents)
must be set to Yes for all receipt-related documents such as the tally.
OTHER If you want AccellosOne 3PL to generate your pallet ID’s or other inventory levels,
you must set the Method of Generating/Validating Values flag in DILP (Depositor
Inventory Level Profile) to W for Warehouse for that level. As well, the Warehouse
Code field in the receipt header must be populated. See the Setup Guide for
further information on DILP and DIAP.
If you wish to define a default staging and put-away warehouse, you can enter a
warehouse code in either the header block of ENRE (for a given receipt) or in
CUST (for all receipts for a given customer). If you enter a default warehouse
code in both ENRE and CUST, the ENRE code will override the CUST code.
If you wish to display a depositor print message set up in DPME, attach a docu-
ment code of TALY to your message code in DPME. DPME messages for RFCH
require specific customer/carrier/shipper combinations; you cannot use the “.ALL”
codes.
NOTE A DPME message for RFCH does not actually print unless you set up a
real tally document in DOCU and then attach this tally document to an inbound
flow in DIFP.
RESTRICTIONS RFCH does not support lines that have been partially received in ENRE. A line is
considered partially received if you add a location line record in ENRE to a receipt
line and the quantity of the location line is less than the full number of units for the
receipt line.
In one-step manual put-away, you unload your receipt and place it in a final non-staging location with no
processing in RFPU. The mode for one-step put-away in RFCH is P for Put-Away and the non-staging
location is manually selected by the operator.
FLOWS For one-step manual put-away, the Assign Location flag in DIFP must be set as
follows:
ENRE = Y
DRDO = N
STUN = N/A
INST = N/A
STPU = N
PUCO = N
CORE = N/A
NOTE If you wish to perform two-step put-away for some receipts and one-
step put-away for other receipts, use the flow settings for two-step put-away.
AUTO-CONFIRMA- If you wish to deactivate automatic confirmation of receipts, you must create a
TION new flow and attach it to your inbound flow profile. This flow must be placed
before CORE (Confirm Receipt) and the Mandatory flag for this flow in DIFP must
be set to Y for Yes.
In one-step directed put-away, you unload your receipt and place it in a final non-staging location with
no processing in RFPU. The mode for one-step put-away in RFCH is P for Put-Away and the non-stag-
ing location is selected by the system. Directed put-away requires special setup in ILOP (Item Location
Profile) and other programs. See the Allocation and Wave Manager for further information.
FLOWS For one-step directed put-away, the Assign Location flag in DIFP must be set as
follows:
ENRE = Y
DRDO = Y
STUN = N/A
INST = N/A
STPU = Y
PUCO = Y
CORE = N/A
NOTE If you wish to perform two-step put-away for some receipts and one-
step put-away for other receipts, use the flow settings for two-step put-away.
AUTO-CONFIRMA- If you wish to deactivate automatic confirmation of receipts, you must create a
TION new flow and attach it to your inbound flow profile. This flow must be placed
before CORE (Confirm Receipt) and the Mandatory flag for this flow in DIFP must
be set to Y for Yes.
In two-step put-away, you unload your receipt and place it in a staging location before performing final
put-away in RFPU. The mode for two-step put-away in RFCH is U for Unload and both the staging and
non-staging locations are manually selected by the operator.
FLOWS For two-step put-away with manual staging, the Assign Location flag in DIFP
must be set as follows:
ENRE = N
DRDO = N
STUN = N
INST = N
STPU = N
PUCO = N
CORE = N/A
In two-step put-away, you unload your receipt and place it in a staging location before performing final
put-away in RFPU. The mode for two-step put-away in RFCH is U for Unload and the staging location is
selected by the system while the final non-staging location is selected by the operator. Directed staging
requires special setup in ILOP (Item Location Profile) and other programs. See the Allocation and Wave
Manager Guide for further information.
FLOWS For two-step put-away with directed staging, the Assign Location flag in DIFP
must be set as follows:
ENRE = N
DRDO = Y
STUN = Y
INST = N
STPU = N
PUCO = N
CORE = N/A
ALLOCATION Directed staging requires warehouse zones set up in WHZO (Warehouse Zone
Codes). The zone type code must be set to P (P & D) or S (Sorting) and the stag-
ing location must be defined in the Header Block of WHZO.
In two-step put-away, you unload your receipt and place it in a staging location before performing final
put-away in RFPU. The mode for two-step put-away in RFCH is U for Unload and both the staging and
final locations are selected by the system. Directed put-away requires special setup in ILOP (Item Loca-
tion Profile) and other programs. See the Allocation and Wave Manager Guide for further information.
If you switch from two-step put-away to one-step put-away in RFCH and if you are processing a P-type
line, AccellosOne 3PL will use your directed move parameters rather than your directed put-away
parameters.
FLOWS For two-step put-away with directed staging and put-away, the Assign Location
flag in DIFP must be set as follows:
ENRE = N
DRDO = Y
STUN = Y
INST = Y
STPU = Y
PUCO = Y
CORE = N/A
ALLOCATION Directed put-away requires warehouse zones set up in WHZO (Warehouse Zone
Codes). The zone type code must be set to P (P & D) or S (Sorting) and the stag-
ing location must be defined in the Header Block of WHZO.
OTHER The following parameters must be defined: Directed Move Inbound in ILOP
(Directed Moved Inbound) and Put-Away in ILOP (Put-Away).
In two-step put-away, you unload your receipt and place it in a staging location before performing final
put-away in RFPU. The mode for two-step put-away in RFCH is U for Unload and the staging location is
selected by the operator while the final location is selected by the system. Directed put-away requires
special setup in ILOP (Item Location Profile) and other programs. See the Allocation and Wave Man-
ager Guide for further information.
FLOWS For two-step put-away with manual staging and directed put-away, the Assign
Location flag in DIFP must be set as follows:
ENRE = N
DRDO = N
STUN = N
INST = Y
STPU = Y
PUCO = Y
CORE = N/A
ALLOCATION Directed put-away requires warehouse zones set up in WHZO (Warehouse Zone
Codes). The zone type code must be set to P (P & D) or S (Sorting) and the stag-
ing location must be defined in the Header Block of WHZO.
In three-step put-away, the product is received and staged on the dock, moved to a PnD location by a
forklift operator and then moved to a final put-away location by a narrow aisle equipment (VNA) opera-
tor.
You set up your final put-away locations in the Location Block of WHZO (Warehouse Zones).
FLOWS For three-step put-away with manual staging and directed put-away, the Assign
Location flag in DIFP must be set as follows:
ENRE = N
DRDO = N
STUN = N
INST = Y
STPU = Y
PUCO = Y
CORE = N/A
LOTP The PnD location’s location type must be set up in LOTP as follows:
.
MRFP In the Special Receiving Mode Types field in MRFP, you select from the following
three-step put-away options:
RFCH to General Staging Location, RFPU to a PnD Location, then to Final
Location
RFCH to Gen Stag Loc, RFPU to PnD Loc, then to Final Loc, RFCH Overrides
If you select the first option, three-step put-away is mandatory in RFCH. If you
select the second option, the RF operator can select either two-step or three-step
put-away in RFCH.
In the Picking Rules for PnD Locations field in MRFP, you define your pick meth-
ods for these types of locations: full pallet picks only or all pick methods.
FUNCTION KEYS
Criteria Mode
FUNCTION KEYS
Results Mode
Main Mode
RFCH screen
If you do not know the UI num- a) See “Performing Queries” on page 160.
ber or receipt number:
5 Depending on your system setup, RFCH will be preset to either put-away mode or unload mode. If
required, you can press F3 (CM) to toggle between the two modes.
Once you process a receipt line, the mode is set for all remaining lines on the receipt and cannot be
altered until you start a new receipt.
NOTE If you have manually entered a location in ENRE for one receipt line belong-
ing to a multi-line receipt, the mode for the remaining receipt lines will be preset to
put-away and cannot be changed. To switch to unload mode, you will have to remove
the location from the receipt line in ENRE and then return to RFCH.
7 If the quantity entered does not match the expected quantity, a warning message will appear (“Qty
Entered Does Not Match Expected Qty. Do You Want to Continue (Y/N)”) and you will be prompted to
either continue with the current receipt or work on another receipt.
8 Do one of the following:
If the item that you are receiving If the item that you are receiving
requires the entry of a process does NOT require the entry of a
code value: process code value:
9 If F1 (Rm) is available, the receipt has remarks. You can press F1 to view the remarks and then press F4
to exit the Remarks Block.
a) If required, key in your manual a) If required, you can manually a) The cursor will skip past the
hold code and press Enter. If override or remove the hold Hold field and you will not be
you do not want to place the code. Make any necessary able to override or remove the
product on hold, press Enter changes and press Enter or hold code.
to bypass this field. press Enter without making
any changes to accept the
automatic hold.
11 Proceed to assign a location to the product as follows. If you are working in unload mode, the product
must be placed in a staging location. A staging location is a location whose location type in LOTP is
called STAG. This STAG code must have the Staging flag set to Y for Yes.
If you are working in put-away mode, the product must be placed in a non-staging location. A non-staging
location is a location whose location type in LOTP has the Staging flag set to N for No.
12 If required, you can press F9 to return to the Hold field and place the product on hold.
13 Repeat the above steps for any additional UI’s or receipt lines.
14 When you finish entering all the lines on the receipt, do one of the following:
a) Proceed to next step. The following message will appear: The following message will appear:
15 Press Enter to close the “Process Completed” message. If prompted to mark the receipt as completed or
to create a new line, key in Y for Yes to complete the receipt and press Enter.
16 Process another receipt or press F4 to exit.
The following screen will appear: The following screen will appear:
a) Key in Y for Yes and press Enter a) Key in Y for Yes and press Enter
to proceed with the location over- to proceed with the location over-
ride. If you do not wish to pro- ride. If you do not wish to pro-
ceed with the override, key in N ceed with the override, key in N
for No and press Enter to return for No and press Enter to return
to the main RFCH screen. to the main RFCH screen.
b) Press Enter again to accept the
warehouse that the system-
assigned location belongs to.
1 When you finish processing all UI’s or receipt lines, the following screen will appear:
3 If the trailer checks entry is activated in MRFP, you will be prompted to perform a series of trailer checks.
6 Key in your account code and press Enter or use your pick list to select it. To select a code using the pick
list, press F10 to display the pick list and use your up and down arrow keys to select the appropriate
code. Then press Enter to make your selection. The account is the party (customer, shipper or carrier)
that you are receiving pallets from or shipping pallets to.
7 In the Type field, key in the appropriate value for your pallet transaction (R for Received, S for Shipped or
E for Exchanged) and press Enter.
Received Received means that you are receiving pallets from the
account that you specified in the previous field.
8 Key in your pallet code and press Enter or use your pick list to select it.
9 Key in the number of pallets that you are shipping or receiving and press Enter.
10 If required, key in a remark for the pallet transaction in the Reference field and press Enter. If you do not
require a remark, press Enter to bypass this field.
11 If required, repeat the above steps to add additional lines in the Pallet Block.
12 When you finish adding your lines, press F4 to exit Create Mode. AccellosOne 3PL will display the last
pallet details record that you entered. If you have multiple pallet transactions for this receipt, you can use
your up and down arrow keys to scroll through the list of records.
If you wish to delete a pallet transaction, select the transaction that you wish to delete with your arrow
keys. Then press Enter until your cursor is positioned in the NUM PALL field and press F2 (DE).
13 Press F4 again to exit the Pallet Block.
AccellosOne 3PL will redisplay the prompt for the temperature and trailer number.
14 Press F4 to exit this screen.
15 Press Enter to close the “Process Complete” message. If prompted to mark the receipt as completed or
to create a new line, key in Y for Yes to complete the receipt and press Enter.
16 Press F4 to exit.
PERFORMING QUERIES
The query function in RFCH allows you to query by receipt number, receipt line number, customer, inventory
level, warehouse, hold code and shipper. In order to query a receipt in RFCH, the receipt must be at the flow
DRDO (Driver Arrived at Door) without being fully staged or put-away.
You can customize the values that appear in the query results screen by setting the appropriate flags in
MRFP (RF Profile Code) to Yes. For example, if you wish to see the customer code and level 1 value only in
the query results, you would set the Show Customer Code in RFCH Query and Show Inventory Level 1 in
RFCH Query fields to Yes.
1 Enter RFCH.
2 Press F2 (QS).
4 Use your arrow keys to scroll through the list of records retrieved. If you wish to jump forward by ten
records, press F1 (JF). If you wish to jump backwards by ten records, press F2 (JB).
5 When you find the line that you wish to select, press F3 to select it.
6 Continue to process the receipt normally.
line 2 0 90
line 2 0 20 STAG
line 3 0 70
line 2 0 20 STAG
line 3 0 50 STAG
line 4 0 20
line 2 0 20 STAG
line 3 0 50 STAG
line 4 0 20 STAG
1 Enter RFCH.
2 Retrieve the inventory entity that you wish to process.
3 If required, change your mode to either put-away or unload.
4 Key in your partial quantity and press Enter.
5 If required, place the product on hold.
6 Assign the product a location.
7 Press F4 to close the receipt.
8 When the Process Complete? message appears, key in Y for Yes and press Enter.
9 Exit RFCH.
PRINTING LABELS
Printing labels requires a document set up by Accellos in DOCU (Documents).
1 Enter RFCH.
2 Press F1 (PL).
6 Key in the number of labels that you wish to print for this inventory entity and press Enter.
7 Key in your printer code and press Enter.
8 Repeat the above steps for each additional label that you wish to print or press F4 the required number of
times to exit.
LINE 1 LINE 2
Item = A1 Item = A1
Lot = 101 Lot = 101
Pallet ID = 001 Pallet ID = 002
Quantity = 100 Quantity = 50
If you enter a quantity of 85 for line 1 and a quantity of 65 for line 2, no variance will occur in RFCH because
the total (85 + 65 = 150) equals the total in ENRE for item A1, lot 101.
If you enter a quantity of 120 for line 1 and a quantity of 45 for line 2, a variance will occur in RFCH because
the total (120 + 45 = 165) does not equal 150. If you accept the variance of 15 units, the extra 15 units will be
applied to line 1; you cannot split an overage or adjustment between two pallet ID’s belonging to the same lot
number.
NOTE All variances in RFCH are shown in the lowest SKU. For example, if your
item is a pallet/case/each item, any variances will be shown in eaches — not pallets
or cases.
PROCESSING VARIANCES
If the RFCH/RFPU Quantity Must Match ENRE Quantity flag in MRFP is set to “Must Match ENRE”, you
cannot enter variances in RFCH. When the quantity received does not match the quantity on the receipt, the
following message will appear and you must either enter the correct quantity or exit the receipt line.
RFCH screen showing “Qty entered does not match expected qty” message
If the RFCH/RFPU Quantity Must Match ENRE Quantity flag in MRFP is set to “Matching not required”, you
can enter variances in RFCH. Variance processing in RFCH is dependent on whether or not the operator has
supervisory privileges.
variance is a shortage “Receipt not completed yet” message “Complete Process” message appears and
appears when you exit the receipt and supervisor is prompted to zero out the lines.
AccellosOne 3PL creates a second line in If the supervisor selects Yes, Variance
ENRE for the missing product. Operator screen appears and supervisor is prompted
can return to the receipt at any time to enter to accept the shortage. No second line is
the missing product or office staff can created in ENRE for the missing product.
delete the second line.
variance is an overage If you enter all your inventory levels manu- Same as operator or non-supervisor.
ally, Variance screen appears when you
enter your quantity. If you do not enter all
your inventory levels manually (that is, a U-
type lines), Variance screen appears when
you exit the receipt. In the Variance screen,
operator is prompted to accept the overage.
In ENRE, received quantity is greater than
expected quantity.
1 Make sure that the RFCH/RFPU Quantity Must Match ENRE Quantity flag in MRFP is set to “Matching
not required”.
2 Enter RFCH.
3 Enter or scan in your UI value or enter your receipt number and all known inventory levels of the product
that you are receiving.
4 Key in your tie, hi and loose values. If you do not wish to record these values, leave the tie field blank and
press Enter to bypass these fields.
5 Key in your quantity and press Enter. If the quantity is already displayed, press Enter to accept it or key in
a new quantity and press Enter.
6 Do one of the following:
7 Proceed to enter your hold code (if any) and location information for the receipt and then perform the
remaining steps in RFCH normally.
8 When you finish processing all your receipt lines, press F4 to switch to main mode.
The following screen will appear: The following screen will appear:
there are no process values for the receipt line that you are processing
there are missing process values for the receipt line that you are processing
the quantity received in RFCH does not match the quantity recorded in ENRE (any existing process val-
ues will be erased and new values must be entered)
If you are unable to scan in each case ID on the pallet for any reason, AccellosOne 3PL will present you with
the following options:
4 (Exit, Save) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned. You
cannot process the receipt line again in RFCH.
5 (Exit, No Save) Cease scanning and exit without saving any process
values including those already scanned. You cannot
process the receipt line again in RFCH.
1 Enter RFCH.
2 Enter or scan in your UI value or enter your receipt number and all inventory levels of the product that
you are receiving.
3 Key in your tie, hi and loose values. If you do not wish to record these values, leave the tie field blank and
press Enter to bypass these fields.
4 Key in your quantity and press Enter. If the quantity is already displayed, press Enter to accept it or key in
a new quantity and press Enter.
5 Key in your first value and press Enter or scan it in using your RF gun.
6 If you are capturing multiple process values, repeat the above step for each additional process value.
7 If you wish to interrupt your scanning for any reason, press F4.
If you wish to exit and short the Key in 3 and press Enter.
received quantity: When prompted to short the receipt line, key in Y for
Yes and press Enter.
If you wish to exit and save the Key in 4 and press Enter.
scanned process values: Press Enter to acknowledge the “Process Complete”
message.
1 Enter RFCH.
2 Enter or scan in your UI value or enter your receipt number and all inventory levels of the product that
you are receiving.
3 Key in your tie, hi and loose values. If you do not wish to record these values, leave the tie field blank and
press Enter to bypass these fields.
4 Key in your quantity and press Enter. If the quantity is already displayed, press Enter to accept it or key in
a new quantity and press Enter.
1 Enter RFCH.
2 Press Enter to bypass the UI field.
3 Key in your receipt number and press Enter.
4 Key in your level 1 value for the item that you wish to receive and press Enter.
a) Key in all inventory levels for the a) Key in all inventory levels for the
item. item except the last level. For
example, if you are receiving a
three-level item, you would enter
the second inventory level but
not the third. If you are receiving
a four-level item, you would enter
the second and third inventory
levels but not the fourth.
6 With your cursor positioned in the field for your lowest inventory level, press F1 (CL). AccellosOne 3PL
will display the following message.
a) Key in Y for Yes and press Enter. a) Key in N for No and press Enter.
b) Key in your quantity and press b) Re-enter the inventory level that
Enter. triggered the “Create a New
Line?” prompt.
1 Make sure that your receipt is at the flow DRDO (Driver Arrived at Door).
2 Enter RFCH.
RFCH screen
a) Enter or scan in your alternate a) Enter or scan in your UI value. a) Press Enter to bypass the UI
item code in the UI field. The The system will retrieve the field.
system will convert the alter- receipt number and three b) Key in your receipt number
nate item code to the regular inventory levels for that UI and press Enter.
AccellosOne 3PL item code. value. The alternate item code c) Enter or scan in your alternate
will be converted to the regular item code. The system will
AccellosOne 3PL item code. convert the alternate item
code to the regular Accel-
losOne 3PL item code.
d) Enter or scan in your remain-
ing inventory levels.
IHOP screen showing Allow Override of Hold Code During Core RF Receiving field set to Y for Yes
1 Enter RFCH.
2 Press Enter to bypass the UI (Unique Identifier) field.
3 Key in your receipt number and press Enter.
4 Enter or scan your level 1 value for the first product that you wish to receive.
5 Enter or scan in your level 2 value. If required, enter or scan in your level 3 and level 4 values.
6 Depending on your system setup, RFCH will be preset to either put-away mode or unload mode. If
required, you can press F3 (CM) to toggle between the two modes.
Once you process a receipt line, the mode is set for all remaining lines on the receipt and cannot be
altered until you start a new receipt.
7 Key in your tie, hi and loose values. If you do not wish to record these values, press Enter three times to
bypass these fields.
8 Key in your quantity in the lowest SKU and press Enter.
9 Continue to process the receipt normally in RFCH.
Receiving mixed product on a single pallet requires that the Receipt Reference Number field in ENRE be
populated with the level 3 or 4 value that you scan in RFCH.
1 Enter RFCH.
2 Enter or scan in your UI value or enter your receipt number and all known inventory levels of the product
that you are receiving.
a) Key in Y for Yes and press Enter. a) Key in N for No and press Enter.
b) Proceed to enter the quantity b) Proceed to enter the quantity
and location for the full pallet. and location for the first inventory
c) If prompted to do so, enter your entity on the pallet.
trailer and pallet information in c) Repeat the previous step for
the normal manner. each additional inventory entity
on the pallet.
d) If prompted to do so, enter your
trailer and pallet information in
the normal manner.
1 Enter LORE.
2 Retrieve the receipt whose temperature and trailer information you wish to look up.
3 Make sure that the value in the Carrier Details field is E for Entered.
4 Press Enter to position your cursor in the Carrier Details field.
5 Click on Carrier Details.
6 Click on Return to exit the Carrier Details Block. Then click on Exit to exit.
1 Enter RFCH and retrieve the receipt whose remarks/messages you wish to look up. The remark/mes-
sage will display automatically when you retrieve the receipt.
2 If the remarks are more than six lines long, use your up and down arrow keys to scroll through the remark
lines.
3 If there are multiple remarks/messages attached to the receipt, press Enter or F4 to jump to the next
message.
4 Continue to process the receipt normally.
This program allows you to enter temperature, trailer/seal number and pallet information for a given receipt or
order without working in RFCH or RFPIC. The information that you can enter in RFTT — temperature only,
trailer/seal number only, temperature and trailer/seal number, etc. — depends on which option you choose in
the Show Temperature and Pallet Blocks field in MRFP.
1 Enter RFTT.
RFTT screen
You put away your product in RFPU. RFPU can only be used after unloading the product in RFCH. If you wish
to put-away product without unloading it, you must perform one-step put-away in RFCH.
When putting away product, you can enter the exact quantity (that is, the expected quantity equals the
received quantity), an overage or a shortage and, if required, you can place product on a manual hold. You
can also split a line; that is, if your receipt line has 50 units, you can put-away 30 units today in one location
and put-away the remaining 20 units at a later time in the same location or in another location.
There are four different hold options in RFPU:
If you enter a shortage … You can place a manual hold on the difference between the
expected quantity and the received quantity. For example, if the
quantity staged in RFCH is 100 units and you enter 80 for the same
receipt line in RFPU, AccellosOne 3PL will place 20 units on the
hold that you specify.
If the entire receipt line is damaged or You can place an entire receipt line on a manual hold.
requires special processing …
If you enter a shortage and the non-short- You can place two manual holds on the same receipt line: one hold
age part of the receipt line is damaged or for the variance quantity and a second hold for the non-variance
requires special processing … quantity.
If automatic holds are activated for the If manual overriding of holds is activated in IHOP, you can manually
product … override or remove the hold code. If manual overriding of holds is
NOT activated in IHOP, you cannot override or remove the hold
code.
If directed put-away is activated on your system, the system-assigned warehouse and location will be
displayed. You can accept the system-assigned warehouse and location or you can enter a new warehouse
and location. If directed put-away is not activated on your system, you must enter your put-away location and
warehouse manually. You can eliminate the need to enter a warehouse in RFPU by defining a default
warehouse in the header block ENRE (for a given receipt) or in CUST (for all receipts from a given customer).
If automatic confirmation is activated, RFPU advances the receipt’s flow to CORE. Therefore, you cannot
work on or make adjustments to the receipt after processing it in RFPU.
R EQU IR E M E N T S
FLOWS See “Unloading Product in RFCH” on page 140 for further information.
LINE TYPES RFPU requires P-type lines unless U-type lines have been received with a quan-
tity of zero.
R EQU IR E M E N T S
AUTO-CONFIRMA- If you wish to deactivate automatic confirmation of receipts, you must create a
TION new flow and attach it to your inbound flow profile. This flow must be placed
before CORE (Confirm Receipt) and the Mandatory flag for this flow in DIFP must
be set to Y for Yes.
DOCUMENTS The Print Document Without Assigning Locations flag in DOCU (Documents)
must be set to Yes for all receipt-related documents such as the tally.
OTHER The product must have been placed in a staging location in RFCH.
FUNCTION KEYS
Main Mode
Results Mode
1 Make sure that your receipt in ENRE is at one of the following flows: DRDO (Driver at Door), STUN (Start
Unloading), INST (Inbound Staged) or STPU (Start Put-Away).
2 Enter RFPU.
RFPU screen
If you know the UI value of the If you do NOT know the UI value
product that you are putting of the product that you are
away: putting away:
4 If F1 (Rm) is available, the receipt has remarks. You can press F1 to view the remarks and then press F4
to exit the Remarks Block.
5 Key in the quantity that you are receiving and press Enter. You can enter your quantity in pallets, eaches
or any other SKU type that is activated in the item’s quantity breakdown. If your default SKU type is
eaches and you wish to enter a quantity of 10 pallets, you would key in 10P for 10 pallets.
6 Do one of the following:
a) If you wish to place the prod- a) If required, you can manually a) The cursor will skip past the
uct on manual hold, press F9 override or remove the hold Hold field and you will not be
to position your cursor in the code. Make any necessary able to override or remove the
Hold field. Then key in your changes and press Enter or hold code.
manual hold code and press press Enter without making
Enter. any changes to accept the
The hold that you enter in this field automatic hold.
applies to the entire receipt line — if
you did not record a variance in the
Quantity field — or the difference
between the variance and the
expected quantity — if you did record
a variance in the Quantity field.
AccellosOne 3PL will display the a) Key in your location and press
system-assigned warehouse and Enter.
location. You can accept the sys- b) If required, key in your ware-
tem-assigned warehouse and loca- house and press Enter. You will
tion or you can enter a different not need to enter a warehouse if
warehouse and location. you defined a default warehouse
in either ENRE or CUST.
If you wish to override the system-
assigned location, see “Overriding
the System-Assigned Location” on
page 184.
F = from location
S = system location
T = to location
10 Repeat the above steps for the each additional receipt line that you wish to put away.
11 When all your lines have been put-away, the following message will appear:
12 Press Enter to accept the message then process another receipt or press F4 to exit.
The following screen will appear: The following screen will appear:
a) Key in Y for Yes and press Enter a) Key in Y for Yes and press Enter
to proceed with the location over- to proceed with the location over-
ride. If you do not wish to pro- ride. If you do not wish to pro-
ceed with the override, key in N ceed with the override, key in N
for No and press Enter to return for No and press Enter to return
to the main RFPU screen. to the main RFPU screen.
b) Press Enter again to accept the
warehouse that the system-
assigned location belongs to.
ENTERING VARIANCES
If the RFCH/RFPU Quantity Must Match ENRE Quantity flag in MRFP is set to “Must match ENRE”, you
cannot enter variances in RFPU. When the quantity received does not match the quantity on the receipt, the
following message will appear and you must either enter the correct quantity or exit the receipt line.
RFPU screen showing “Qty entered does not match expected qty” message
If the RFCH/RFPU Quantity Must Match ENRE Quantity flag in MRFP is set to “Matching not required”, you
have four options:
you can ignore the variance for now because you expect to receive more product
you can reject the variance and re-enter the quantity
you can place the variance quantity on hold
you can accept the variance
If you accept the variance, AccellosOne 3PL will create one line in the Location Block of ENRE for the flow
CORE (Confirm Receipt) showing the actual quantity received. If you place the variance quantity on hold,
AccellosOne 3PL will create two lines in the Location Block of ENRE for the flow CORE (Confirm Receipt):
one line showing the actual quantity received with no hold code and a second line showing the variance
quantity with the hold code that you specified in RFPU.
LORE screen showing 80 cases with no hold in location A101 and 20 cases on damaged hold in the
same location
1 Make sure that your receipt in ENRE is at one of the following flows: STUN (Start Unloading), INST
(Inbound Staged) or STPU (Start Put-Away).
2 Enter RFPU.
RFPU screen
a) Enter or scan in your alternate a) Enter or scan in your UI value. a) Press Enter to bypass the UI
item code in the UI field. The The system will retrieve the field.
system will convert the alter- receipt number and three b) Key in your receipt number
nate item code to the regular inventory levels for that UI and press Enter.
AccellosOne 3PL item code. value. The alternate item code c) Enter or scan in your alternate
will be converted to the regular item code. The system will
AccellosOne 3PL item code. convert the alternate item
code to the regular Accel-
losOne 3PL item code.
d) Enter or scan in your remain-
ing inventory levels.
RFIPS is a stand-alone version of the process value module in RFCH. It allows you to scan in process values
without assigning the product to a final put-away location.
R EQU IR E M E N T S
LOCATION STA- If there is an MRFP profile attached to the customer in CUST, the receipt line
TUS must be assigned a location. If there is no MRFP profile attached to the customer
in CUST, a location for the receipt line is not required.
CATCH WEIGHT See “Setting Up Catch Weight Tolerances” on page 259 for further information.
TOLERANCES
1 Enter RFIPS.
RFIPS screen
RFIPS screen
4 Key in your first value and press Enter or scan it in using your RF gun.
5 If you are capturing multiple process values, repeat the above step for each additional process value.
6 If you wish to interrupt your scanning for any reason, press F4.
If you wish to continue from where you Key in 1 and press Enter.
left off:
If you wish to exit and short the Key in 3 and press Enter.
received quantity: When prompted to short the receipt line, key in Y for Yes and press
Enter.
If you wish to exit and save the Key in 4 and press Enter.
scanned process values:
If you wish to exit without saving the Key in 5 and press Enter.
scanned process values:
You can delete a receipt line in RFDL if the receipt line has not been confirmed.
1 Enter RFDL.
RFDL
Overview of Shipping
In non-RF shipping, you time-stamp and advance the flow of an order in CHOF (Time-Stamp and Confirm
Orders). Advancing the flow of an order in CHOF advances the flow of all order lines and order location lines
on the order. You cannot advance the flow of one order line and leave another order line remain at its original
flow.
In RF shipping, on the other hand, AccellosOne 3PL automatically advances the flow of individual order lines
and order location lines. For example, when you pick an order line in RFPIC, the order line’s flow is automati-
cally advanced from STPI (Start Picking) to FIPI (Finish Picking). Because the flow of individual order lines is
advanced as each order line is picked, not all lines on a given order will be at the same flow. When this
happens, the order header will show the earliest flow on the order.
For example, suppose there are five order lines on a given order: two lines are at the flow STPI, two lines are
at the flow FIPI and one line is at the flow STLO (Start Loading). If you look up the order in LOOR, the order’s
flow will be set to STPI, which is the earliest flow.
Pick methods allow you to split order lines into two or more pick method assignments. For example, if your
order line quantity was two pallets and 10 cases, you might want to assign one RF operator with a forklift to
pick the two pallets and another RF operator with a different piece of equipment to pick the 10 cases. Without
pick methods, you would be forced to assign the entire order line quantity to a single RF operator using a
single piece of equipment. This could be an inefficient use of resources.
Pick methods also allow you to define a sequence for your picking; for example, pick cases/eaches first
because it is complex and time-consuming and pick full pallets last because it is simple and straightforward.
Different pick methods can have different label printing requirements; you can attach different customer/
consignee/carrier combinations to a particular pick method/document in CCDU (Customer/Consignee
Document Setup).
Pick methods are assigned to order lines in the Wave Manager based on the order line quantity and your item
setup. For example, if your order line quantity is one pallet, the pick method will be set to PALL.
N AM E CODE D E S CR I P T I O N
CASE A normal case pick in RFPIC. The Pick Method field in LOOR for this pick
method is left blank to indicate that it is the system default.
Batch Label Pick BATP A batch pick across multiple orders when two or more orders in the wave are
being picked up by the same carrier and the carrier type = UPS, DHL or
FEDEX.
Each Pick EACH A Pick & Pack by each (the smallest SKU in an item’s quantity breakdown).
Label Pick LABP An individual order pick when a single order is being picked up by a given car-
rier.
Non-RF Packing Station PKST Manual packing performed in EPSD (Enter Packing Details).
Packed via Packing Sta- PACK First level cartonization performed in RFSC (RF Sort to Carton) or RFPK (RF
tion Wave Pick).
Pallet Pick PALL A full pallet pick. The order quantity of each order line must equal a full pallet
quantity.
System-Driven Cartoni- CART A Pick & Pack by each used in system-driven cartonization.
zation Each Pick
There are four possible RF picking programs in AccellosOne 3PL: RFPIC, RFPK, RFPV and RFINVT.
RFPIC is AccellosOne 3PL’s most basic picking program. You can pick product by zone or by order number.
Orders must be fully allocated before you can pick them in RFPIC. You cannot pick an order if some lines are
allocated (R-type) and other lines are unallocated (P-type).
If you are picking full pallets from bulk, you scan in the original pallet ID of the pallet and use this pallet ID for
the duration of the outbound process. If you are picking cases from either bulk or the pick line, you scan in the
original pallet ID for each case pick. When you finish building your pallet, you have two options for the
outbound pallet containing mixed product:
if AccellosOne 3PL generates your pallet ID for outbound pallets, you generate your label and then send
it to the appropriate printer
if you use your own preprinted labels for outbound pallets, you enter or scan in the preprinted pallet ID
When you finish generating or scanning in your pallet ID label, you can look up your pallet ID in the
Processing Block of LOOR for each item on the pallet.
If the product that you are picking is not in its assigned location, you have two options. If you know where the
product is, you can go to that location and pick it. If you do not know where the product is, you can place the
product on hold to indicate that it could not be picked.
R EQU IR E M E N T S
NOTE Your CP code set up in IPRO must NOT be attached to the IPRP profile
attached to ITEM.
If you want AccellosOne 3PL to generate a unique pallet ID for each pallet label,
there are three additional requirements:
you need to set up a code in NUSE (Number Series)
you need to attach to your NUSE code to a DIAP (Depositor Inventory Assign
Profile) called QRS
you need to set the Outbound Pallet ID Label field on the RFPIC (2) tab in
MRFP to either option 2 or option 3
NOTE Your QRS code set up in DIAP must NOT be attached to DILP (Depos-
itor Inventory Level Profile).
R EQU IR E M E N T S
ITEM MESSAGES If you define a message in MESS (Messages) and attach the message to an item
in ITEM, the message will display in a pop-up window when you process an order
line for that item.
R EQU IR E M E N T S
DEPOSITOR If you wish to display a depositor print message set up in DPME, attach a docu-
PRINT MESSAGES ment code of PICK to your message code in DPME. DPME messages for RFPIC
require specific customer/carrier/consignee combinations; you cannot use the
“.ALL” codes.
NOTE A DPME message for RFPIC does not actually print unless you set up
a real pick document in DOCU and then attach this pick document to an outbound
flow in DIFP.
See “Entering Process Values in RFOPS” on page 260 for further information for
further information.
SCAN PARAME- Only required if you are scanning process values, inventory levels or UI values
TER CODE from a bar code label
See “Entering Process Values in RFOPS” on page 260 for further information for
further information.
BAR CODE PRO- Only required if you are scanning a UI value or inventory levels from a bar code
FILE label
You must define a bar code profile in BAPR and attach to it the scan parameter
code that you set up in SCPR.
PALLET BLOCK If you wish to ship, receive and exchange pallets, you must set the Display Pallet
Screen field in MRFP (RFPIC tab) to the appropriate value: Display Before Pick-
ing or Display on Completion of Picking.
CONSOLIDATED If you consolidate your orders in COPI (Consolidated Pick), you must set the
ORDERS Default Mode in MRFP (RFPIC tab) to Only Pallet Picking.
FUNCTION KEYS
All Modes
1 Make sure that your order is at the flow SUAL (Supervisor Allocated) or STPI (Start Picking).
2 Enter RFPIC.
RFPIC screen
a) Key in your zone code and press a) Press Enter to bypass the Zone
Enter. field.
b) If required, key in your order b) If required, key in your ware-
number and press Enter. house and press Enter.
c) Key in your order number and
press Enter.
4 If there is a remark attached to the order, press Enter twice to acknowledge it.
5 Do one of the following:
If the default mode for RFPIC has If the default mode for RFPIC has
been set to Case: been set to Pallet:
The message “You have selected CP The message “You have selected NM
Mode” will appear. mode” will appear.
a) Key in N for No and press Enter. a) Press Enter to continue.
RFPIC screen showing pick list of order lines, items and locations to pick
6 The pick list of order lines is initially shown in location code sequence. If you wish to display the list in
Level 1 sequence, press F1 (L1). If you wish to display the list in Level 4 or lowest inventory level
sequence, press F2 (L4). If the list is in Level 4 sequence, you can press F2 again to return to the loca-
tion code sequence.
7 Use your arrow keys to position your cursor over the order line that you wish to pick, then press F3
(Select).
a) If the lowest inventory level is a) All inventory levels for the prod-
represented by a plus sign (+), uct to be picked will be shown.
you can enter any value for that The lot number, pallet ID, etc.
level. If the lot number, pallet ID, that you enter must match the
etc. is represented by an actual values displayed on your screen.
value, you must enter that value; If you attempt to enter different
any other value will be rejected values, they will be rejected by
by the system. the system.
10 Key in your pick quantity and press Enter. If your pick quantity is less than your order quantity, see “Plac-
ing Product on Hold” on page 214 for further instructions.
11 If prompted to do so, enter or scan in your staging location as well as the staging location’s warehouse.
If the order is on a load, the door’s staging location from the load will be shown.
12 When the pick list of unpicked order lines reappears, repeat the above steps for each additional line on
the order.
13 When you finish entering your order lines, the message “ORDER COMPLETED” may appear. If it does,
press Enter to acknowledge it.
14 Process another order or press F4 to exit.
PICKING CASES
When you pick cases, you must print a pallet ID label for each pallet that you build. You can place as many
cases as you want on a pallet, but all cases must belong to the same order; you cannot place product from
different orders on the same pallet.
If you are picking from a pick line, case pick mode is automatically activated in RFPIC unless the Default
Mode field in MRFP set to Only Pallet Picking.
1 Make sure that your order is at the flow SUAL (Supervisor Allocated) or STPI (Start Picking).
2 Enter RFPIC.
RFPIC screen
a) Key in your zone code and press a) Press Enter to bypass the Zone
Enter. field.
b) If required, key in your order b) Key in your warehouse and
number and press Enter. press Enter.
c) Key in your order number and
press Enter.
4 If there is a remark attached to the order, press Enter twice to acknowledge it.
If the default mode for RFPIC has If the default mode for RFPIC has
been set to Case: been set to Pallet:
The message “You have selected CP The message “You have selected normal
Mode” will appear. mode” will appear.
a) Press Enter to continue. a) Key in N for No and press Enter.
RFPIC screen showing list of order lines, items and locations to pick
6 The pick list of order lines is initially shown in location code sequence. If you wish to display the list in
Level 1 sequence, press F1 (L1). If you wish to display the list in Level 4 or lowest inventory level
sequence, press F2 (L4). If the list is in Level 4 sequence, you can press F2 again to return to the loca-
tion code sequence.
7 Use your arrow keys to position your cursor over the order line that you wish to pick.
8 Press F3 (Select).
a) If the lowest inventory level is a) All inventory levels for the prod-
represented by a plus sign (+), uct to be picked will be shown.
you can enter any value for that The lot number, pallet ID, etc.
level. If the lot number, pallet ID, that you enter must match the
etc. is represented by an actual values displayed on your screen.
value, you must enter that value; If you attempt to enter different
any other value will be rejected values, they will be rejected by
by the system. the system.
11 Key in your pick quantity and press Enter. If your pick quantity is less than your order quantity, see “Plac-
ing Product on Hold” on page 214 for further instructions.
12 Do one of the following:
AccellosOne 3PL will display the AccellosOne 3PL will display the
a) Proceed to next step.
list of unpicked order lines. list of unpicked order lines.
a) Select the line that you wish to a) Press F4 to exit the list.
pick and repeat steps 6 to 12 b) Proceed to next step.
for that line.
a) Press Enter to generate your a) Enter or scan in your pallet ID. a) If the PRT (Printer) field is not
pallet ID. b) If required, key in your printer populated, key in your printer
b) If required, key in your printer code and press Enter. code and press Enter.
code and press Enter.
c) If prompted to validate your
pallet ID, enter or scan it in.
15 Enter or scan in your to location. Your to location must be a staging location. If prompted to do so, enter
your to warehouse.
16 Process another order or press F4 to exit.
3 (Exit, Short) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned and
remove unscanned quantities from the to ship quantity.
You cannot process the order line again in RFPIC.
4 (Exit, New Line) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned,
remove the unscanned quantities from the to ship
quantity and will create a new line for the balance.
5 (Exit, Cancel Picking) Cease scanning and exit without saving any process
values including those already scanned. The order line
will revert to its original status before being picked in
RFPIC.
6 (Replace DAMG) Remove a damaged case from the order and replace it
with an undamaged case.
7 (Exit Scan, Save) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned.
1 Scan all cases that you are shipping for the pallet. The system will prompt you when you are complete.
2 If you are unable to scan all cases for any reason, press F4 after scanning the last scannable case.
If you wish to exit and short the Key in 3 and press Enter.
to ship quantity: When prompted to short the order line, key in Y for Yes
and press Enter.
1 Enter RFPIC.
2 Select the product that you wish to pick from the pick list of order lines.
3 Enter or scan in your from location.
4 Enter or scan in your UI value.
5 Key in your pick quantity and press Enter.
6 If prompted to do so, enter or scan in your staging location as well as the staging location’s warehouse.
If you wish to scan the cases to If you wish to scan the order
be removed: quantity:
a) Key in Y for Yes and press Enter. a) Key in N for No and press Enter.
b) Scan in the cases to be b) Scan in the cases to be picked.
removed.
8 When all your cases are scanned, process another order line or press F4 to exit.
R EQU IR E M E N T S
MRFP Suspended holds are not available if the Allow Suspended Holds field in MRFP
(RFPIC tab) is set to “Split Order Line, No Suspended Holds”.
1 Enter RFPIC.
2 Retrieve the order that you wish to process.
3 Use your arrow keys to position your cursor over the order line that you wish to pick and press F3
(Select).
a) Press F3 (Hold). a) Enter or scan in your from a) Enter or scan in your from
location. location.
b) Enter or scan in your UI. b) Enter or scan in your UI.
c) Key in the number of units that c) Key in the number of units that
are NOT on hold and press are NOT on hold and press
Enter. Enter.
d) Press F3 (Hold) to place the
remaining units in your ware-
house on hold.
5 If a supervisor is required to approve the hold, the Supervisor Screen will appear.
After signing on, the supervisor will be prompted to accept or reject the hold.
6 If the supervisor approves the hold, enter or scan in your staging location.
7 When the pick list of unpicked order lines appears, do one of the following:
If you placed the entire pallet on If you placed one or more cases
hold in step 4: on hold in step 4:
1 Enter RFPIC.
2 Enter your zone and/or warehouse and order number in the usual manner.
4 Key in your account code and press Enter or use your pick list to select it. To select a code using the pick
list, press F10 to display the pick list and use your up and down arrow keys to select the appropriate
code. Then press Enter to make your selection. The account is the party (customer, shipper or carrier)
that you are receiving pallets from or shipping pallets to.
5 In the Type field, key in the appropriate value for your pallet transaction (R for Received, S for Shipped or
E for Exchanged) and press Enter.
Received Received means that you are receiving pallets from the
account that you specified in the previous field.
6 Key in your pallet code and press Enter or use your pick list to select it.
7 Key in the number of pallets that you are shipping or receiving and press Enter.
8 If required, key in a remark for the pallet transaction in the Reference field and press Enter. If you do not
require a remark, press Enter to bypass this field.
9 If required, repeat the above steps to add additional lines in the Pallet Block.
10 When you finish adding your lines, press F4 to exit Create Mode. AccellosOne 3PL will display the last
pallet details record that you entered. If you have multiple pallet transactions for this order, you can use
your up and down arrow keys to scroll through the list of records.
If you wish to delete a pallet transaction, select the transaction that you wish to delete with your arrow
keys. Then press Enter until your cursor is positioned in the NUM PALL field and press F2 (DE).
11 Press F4 again to exit the Pallet Block.
12 Continue to process your order in the normal manner.
1 Enter EOSU.
EOSU screen
3 Key in your search criteria for the orders that you wish to exclude and click on Execute Query to
execute the query.
4 Proceed to select the orders that you wish to exclude from overpicking as follows:
5 When you finish selecting your orders, click on Enable RF Overpick . The Substitution Flag beside
the selected order(s) will change from N or blank to Y. If you make a mistake and wish to reverse your
action, select the orders that you enabled and click on Disable RF Over-Pick .
For example, suppose your order quantity is 10 cases, there are only five cases in the pick line and the
replenishment quantity is 60 cases. The operator can choose to pick the 10 cases from a bulk or non-pick line
location instead of waiting for a replenishment and picking from the pick line. The 10 cases picked from bulk
is subtracted from the replenishment quantity; 60 -10 = 50.
RFPIC screen showing prompt to pick from replenishment location rather than pick line location
To activate pick line picking from a non-pick line location, you must set the flag in MRFP called Allow Picking
Outside of Pick Line to Yes.
1 Enter RFPIC and retrieve the order whose remarks/messages you wish to look up. The remark/message
will display automatically when you retrieve the order.
2 If the remarks are more than six lines long, use your up and down arrow keys to scroll through the remark
lines.
3 If there are multiple remarks/messages attached to the order, press Enter or F4 to jump to the next mes-
sage.
1 Enter RFPIC.
2 Retrieve the order that you wish to pick.
7 Key in the quantity of product remaining in the location and press Enter. If the location contains mixed
product, count only the product that you are picking.
1 Enter ICIN.
2 Click on Enter Criteria.
If you wish to view all records in If you wish to restrict your query
ICIN: to certain records:
1 Enter RFCL.
RFCL screen
If you wish to view all records in If you wish to restrict your query
RFCL: to certain records:
1 Enter ICIN.
2 Retrieve the record that you wish to remove.
3 Do one of the following:
1 Enter RFCL.
2 Retrieve the record that you wish to remove.
3 Press F3 (Rm).
4 When the message “Record is Deleted Enter to Continue” appears, press Enter to continue.
5 Press F4 to exit.
This program allows you to enter temperature, trailer/seal number and pallet information for a given receipt or
order without working in RFCH or RFPIC. The information that you can enter in RFTT — temperature only,
trailer/seal number only, temperature and trailer/seal number, etc. — depends on which option you choose in
the Show Temperature and Pallet Blocks field in MRFP.
1 Enter RFTT.
RFTT screen
There are three ways of looking up your OPID’s (outbound pallet ID’s):
from the desktop program LOCN (Look Up Carton)
in the RF program RFNCO (OPID Look-Up)
from the desktop program LOOR (Look Up Orders)
1 Enter LOCN.
1 Enter RFNCO.
RFNCO
3 If there are multiple records in the Line Block, you use your Up and Down arrow keys to scroll through the
list.
4 When you finish looking up your OPID’s, press F4 the required number of times to exit.
This program allows you to confirm orders by OPID (outbound pallet ID) without the need to confirm the entire
order in CHOF. If an OPID contains multiple order lines, you can confirm individual orders lines or you can
confirm all order lines assigned to the OPID. If you choose to confirm individual order lines, the Shipped Date
field in the Line Block of LOOR will be populated for each order line confirmed in RFCO.
R EQU IR E M E N T S
DOCUMENTS You cannot use RFCO if you print one or more documents at your FIPI (Finish
Picking) flow because the flow FIPI is bypassed in RFCO. To use RFCO, you
must move your document(s) to the COOR (Confirm Order) flow.
1 Enter RFCO.
RFCO screen
4 Repeat the above steps for another OPID or press F4 (EX) to exit.
This program allows you to confirm individual order lines by UI. When you look up the order in LOOR, the
Shipped Date field in the Line Block will be populated for each order line confirmed in RFCU.
1 Enter RFCU.
RFCU
In this program, you can reprint outbound labels for orders that have already been picked in RFPIC. There
are two reprint modes in RFOLP depending on the outcome of label printing in RFPIC.
If the original label printed correctly in RFPIC, you enter the UI value of the order line or the OPID of the
original label in RFOLP. If label printing failed in RFPIC due to a lost connection or loss of power, AccellosOne
3PL will generate an internal tag number and attach this tag number to all order lines that have been picked.
The way that you process these order lines that have been picked depends upon how you create your
OPID’s:
if you manually create your OPID’s, you must enter ENOR and change the tag number in the Process
Block to the desired OPID number and use this number as your OPID number (AccellosOne 3PL will
replace the tag number for all order lines that have been picked by the new OPID number)
if your OPID’s are system generated, you must enter LOOR and look up the tag number assigned to the
order line in the Process Block and use this tag number as your OPID number (when you finish reprint-
ing in RFOLP, AccellosOne 3PL will assign the new system-generated OPID number to all order lines
that have been picked)
LOOR screen showing tag number generated in Process Block when label printing fails
R EQU IR E M E N T S
2 Enter RFOLP.
RFOLP screen
5 Key in the number of labels that you wish to print/reprint and press Enter.
6 Do one of the following:
In this program, you can pick partial quantities (that is, less than a full pallet) from a pick line in Skip mode. In
Skip mode, automatic replenishment is deactivated and the picker can select any pick line inventory from any
pick line location whose level 1 value matches the level 1 value of the order line.
CASE is designed for fast-moving pick lines in which old product (that is, allocating in FIFO/LIFO sequence)
is not an issue and manual procedures are in place to ensure that the pick line never runs out of product. If
you activate Skip mode, you will not be able to pick partial quantities from a pick line in RFPIC.
When you allocate an order in Skip mode, the following events occur in AccellosOne 3PL:
the P-type order line for the pick line quantity will not be changed to R for Regular
the Location Status field of the order header will be updated to “Entered”, but no locations will be
assigned to the order lines
no replenishments will be generated
NOTE If the order quantity is such that both a bulk pick and a pick line pick are
required (for example, order quantity = 110 cases or 1 pallet/10 cases), AccellosOne
3PL will create a second order line for the pick line pick. However, the non-pick line
pick will allocate normally; that is, the P-type line will change to R for Regular.
R EQU IR E M E N T S
FLOWS See “Picking Orders in RFPIC” on page 199 for further information.
CASE PICK LABEL See “Picking Orders in RFPIC” on page 199 for further information.
OTHER You need a pick line for the product that you wish to pick in CASE. See the Allo-
cation and Wave Manager for instructions on setting up a pick line.
In the DSRP (Depositor Shipping and Receiving) record attached to the customer
that you are setting up for CASE picking, the Change Zero Pending Line to R-
Type Line field must be set to N for No.
In the PIPR (Picking Profile) record attached to the customer that you are setting
up for CASE picking, the following setups are required:
Use FIFO/LIFO for Pick Line Picking or Skip = S for Skip
R EQU IR E M E N T S
PROCESS VAL- See “Picking Orders in RFPIC” on page 199 for further information.
UES
SCAN PARAME- Only required if you are scanning process values, inventory levels or UI values
TER CODE from a bar code label
BAR CODE PRO- Only required if you are scanning a UI value or inventory levels from a bar code
FILE label
HOLDS See “Picking Orders in RFPIC” on page 199 for further information.
1 Enter CASE.
CASE screen
Record 1
Record 2
CASE screen showing pick list of possible pick locations for order line 1
AccellosOne 3PL will display all locations in the pick line containing the product whose level 1 value
matches the level 1 of the order line. For each location, CASE will display the order line number, ware-
house, level 1 value and pick quantity.
3 Use your arrow keys to position your cursor over the order line/location that you wish to pick, then press
F3 (Select).
4 If you make a mistake and wish to work on another order or order line, press F2 (QU for Quit) to position
your cursor in the Ord# field. Then enter or scan in another order number or press Enter to work on the
same order but a different order line.
5 Enter or scan in your UI value.
Available quan-
tity in location
CASE screen showing prompt for pick quantity
6 Key in your quantity and press Enter. The quantity that you enter must be less than or equal to the avail-
able quantity in the location.
7 Repeat the above steps for each additional order line to be picked from the pick line.
8 When you finish picking all your order lines, the “Case pick completed” message will appear. Press F4
(Rt) to display the case pick label screen.
a) Press Enter to generate your a) Enter or scan in your pallet ID. a) If the PRT (Printer) field is not
pallet ID. populated, key in your printer
b) Key in your printer code and code and press Enter.
press Enter.
Picking Substitution
Picking substitution allows RF operators to pick product other than the allocated product on the order line.
Depending on the options that you choose, the substituted product:
may or may not be allocated to another order
may or may not be from the same location
may or may not have the same FIFO attributes
may or may not have the same level 2/3/4 values
Regardless of the option that you choose, if the original order line has a hold code, the substituted product
must have the same hold.
Picking substitution is designed to achieve faster picking and increased productivity for the warehouse by
allowing operators to pick the most accessible product in a given location or area without sacrificing FIFO or
other picking requirements.
It is only available for RF picking in the program RFPIC. When the picker enters an inventory level value other
than the value of the allocated line, AccellosOne 3PL will evaluate a) whether picking substitution is allowed
and b) if it is allowed, whether the product picked as a substitute is acceptable.
NOTE Picking substitution offers more flexibility at picking time than does reserve
logic. You can pick product from a location other than the pick location, you can pick
product whose level 2/3/4 value is not an exact match of the product on the order, you
can pick product with a variable quantity breakdown and you can pick product on
another open order.
If picking substitution is not activated, the picker can only pick product not on the order line if reserve logic is
activated.
FIELD DESCRIPTIONS
Description Mandatory
If you select Y for Yes, your picking substitution rules will apply to replenish-
ments as well. If you select N for No, your picking substitution rules will apply
to picking only.
L O C AT I O N T Y P E B L O C K
If you attach a SOSE code to your location type, the substitution pick list in
RFPIC will be sorted in the order that you specify.
L O C AT I O N T Y P E B L O C K
If you select A for Allocated Lot, your range in days value will be based on the
originally allocated product’s receipt/expiry date. If you select O for Oldest Lot,
your range in days value will be based on the oldest lot at the time of alloca-
tion.
Range in Days from Orig- Only available if Range in Days Mode = blank or A for Allocated Lot, if relative
inally Allocated Entity FIFO picking is activated in PIPR and if the PSPR rule “Substitute product
must have equivalent FIFO attributes” is chosen
The number of days that the substituted product’s receipt/expiry date can
exceed the originally allocated product’s receipt/expiry date.
EXAMPLE
Suppose you set the Range in Days from Oldest Lot to 10 in PIPR and the
Range in Days from Originally Allocated Entity in PSPR to 5. During alloca-
tion, AccellosOne 3PL selects Jan. 7 as the lot to pick even though the oldest
lot is Jan. 1. If the picker elects to pick substitute product in RFPIC, any lot up
to Jan 12 will be accepted.
If you leave this field blank, the value of zero will be assumed and the substi-
tuted product’s receipt/expiry date must match the original product’s receipt/
expiry date.
NOTE If your customer has specific FIFO rules such as never ship any-
thing with a date greater than 20 days from the oldest lot, you must make sure
that the sum of the Range in Days from Oldest Lot value in PIPR and the
Range in Days from Originally Allocated Entity value in PSPR does not
exceed 20.
For example, you could set both values to 10 (10 + 10 = 20) or your PIPR
value could be 15 and your PSPR value could be 5. However, you could not
set your PIPR value to 15 and your PSPR value to 10 because product with a
date greater than 20 days from the oldest lot might be shipped.
Range in Days from Old- Only available if Range in Days Mode = O for Oldest Lot, if relative FIFO pick-
est Lot During Allocation ing is activated in PIPR and if the PSPR rule “Substitute product must have
equivalent FIFO attributes” is chosen
The number of days that the substituted product’s receipt/expiry date can
exceed the oldest lot at the time of allocation.
There are five logical groups in PSPR. Each group has two or more mutually exclusive options. From each
group, you select the appropriate option.
The traditional range in days mode option looks at a single order only. The extended range in
days option, on the other hand, looks at all allocated order lines. For example, if your range
in days value is 5, the substituted product’s receipt/expiry date can exceed the receipt /
expiry date of any allocated product that has not been picked.
NOTE The picking substitution rules that you define in PSPR override any picking
parameters that you define in ILOP. For example, if you select “pick to clean” in ILOP
and if the operator decides to pick from another location, that location may not satisfy
the pick to clean requirement. In other words, the operator may pick from a less desir-
able location according to ILOP.
1 Enter PSPR.
2 Click on Create Record.
3 Key in your substitution profile code and press Enter.
4 Key in a description for your new code and press Enter.
5 In the Enable Replenishment Substitution field, key in N for No or Y for Yes and press Enter.
6 In the Location Type Block, click on Return to Main.
7 Click on Create Record.
8 In the Location Type field, key in your location type code and press Enter or use the pick list function to
select it.
9 If required, key in your sort sequence code and press Enter or use the pick list function to select it. If you
do not require a sort sequence code, press Enter to bypass this field.
10 In the Range in Days Mode field, key in A for Allocated Lot or O for Oldest Lot and press Enter.
11 If required, key in the number of days in the Range in Days from Originally Allocated Entity field and
press Enter.
12 In the Available Options Block, use your arrow keys to position your cursor beside the parameter that you
wish to choose and then click on Add Option.
13 Repeat the previous step for each set of parameters.
14 When you finish selecting your parameters, click on Location Type Block.
only product on that order can be picked (other product cannot be substituted for the product on the
order)
product on that order cannot serve as a substitute for product on another order
EOSU shows all open orders that can be excluded from picking substitution. The Substitution flag shows the
current status of each order. A value of Y or blank indicates that picking substitution is enabled for the order.
A value of N indicates that the order is excluded from picking substitution.
1 Enter EOSU.
EOSU screen
2 Key in your search criteria for the orders that you wish to exclude and click on Execute Query to
execute the query.
3 Proceed to select the orders that you wish to exclude from RF substitution as follows:
4 When you finish selecting your orders, click on Enable RF Substitution . The Substitution Flag
beside the selected order(s) will change from N or blank to Y. If you make a mistake and wish to reverse
your action, select the orders that you enabled and click on Disable RF Substitution .
1 Make sure that your order is at the flow SUAL (Supervisor Allocated) or STPI (Start Picking).
2 Enter RFPIC.
3 Do one of the following:
a) Key in your zone code and press a) Press Enter to bypass the Zone
Enter. field.
b) Key in your warehouse and
press Enter.
c) Key in your order number and
press Enter.
4 If there is a remark attached to the order, press Enter twice to acknowledge it.
If the default mode for RFPIC has If the default mode for RFPIC has
been set to Case: been set to Pallet:
The message “You have selected The message “You have selected
CP Mode” will appear. NM mode” will appear.
a) Key in N for No and press Enter. a) Press Enter to continue.
6 When the pick list of order lines is displayed, use your arrow keys to position your cursor over the order
line that you wish to pick, then press F3 (Select).
7 If prompted to enter your from location, enter or scan in the location of the substitute product.
a) The message “No subst. for all a) The following message will a) Enter or scan in its UI value.
loc” will appear. You can only appear:
pick the product on the original
order line.
You enter process values in UOPR. There are two process values that you enter in this program: catch weight
and serial number. You can scan a bar code that contains these two values or you can enter them manually.
UOPR maintains a running total by both weight and number of pieces. The running total shows the weight
and number of pieces that have been scanned in as well as the weight and number of pieces that have not
been scanned in.
If a case has been scanned in error, you can remove it by means of the Reduce command. If a case has not
been scanned, you can remove it from the remaining number of cases to be scanned by means of the
Remove command.
R EQU IR E M E N T S
INVENTORY LEV- You can process up to four inventory levels in UOPR. However, UOPR does not
ELS support product with a single inventory level.
PROCESS VAL- See “Entering Process Values in RFOPS” on page 260 for further information for
UES further information.
SCAN PARAME- See “Entering Process Values in RFOPS” on page 260 for further information for
TER CODE further information.
BASE FOR CUBE/ See “Entering Process Values in RFOPS” on page 260 for further information for
WEIGHT further information.
OTHER If you pick product in RFPIC, you can only enter process values in UOPR after
picking in RFPIC. If you pick product in any other program, you can enter process
values either before or after picking.
FUNCTION KEYS
All Modes
FUNCTION KEYS
1 Enter UOPR.
UOPR screen
If there are multiple order lines/ If there is a single order line for
orders with the same UI: the UI:
6 Repeat the above step for each additional label that you wish to scan.
7 When you finish scanning in all product on the order line, the “Process Complete” message will appear.
Press F4 to exit create record mode.
8 Repeat the above steps for your next UI on the order.
9 When you finish entering all your order lines, press F4 to position your cursor in the Order field.
10 Process another order or press F4 again to exit UOPR.
1 Enter UOPR.
2 Enter or scan in your order number.
3 Enter or scan in your UI number.
UOPR screen showing five cases scanned with a total weight of 123.765
4 Press F2 (RC).
1 Enter UOPR.
2 Enter or scan in your order number.
3 Enter or scan in your UI number.
4 Press F3 (RE).
5 Key in the number of cases that you wish to remove and press Enter.
6 Continue to process the next UI on the order in the normal manner.
1 Enter UOPR.
2 Key in your order number and press Enter.
a) Proceed to next step. a) Enter or scan in your label a) Press F4 (RT) to position your
number. cursor in the UI field.
b) Enter or scan in your new UI
value.
c) Enter or scan in your label
number.
7 When you finish scanning the cases to be removed, press F4 (RT) and F4 (EX) to exit.
1 Enter UOPR.
2 Enter or scan in your order number.
3 Press F1 (SU).
UOPR screen
showing first record
out of two
UOPR screen showing two items on order — first item (five cases) fully scanned while second item
(three cases) unscanned
4 Use your arrow keys to scroll through each unique level 1 on the order.
5 When you finish looking up summary information, press F4 to exit the summary block.
Refer to the section “Item Process Values” in the Operations 2 Guide for further information about setting up
this feature.
1 Enter UOPR.
2 Retrieve the order whose process values you wish to transfer.
The “Wgt transferred” message will appear.
Catch weight tolerances apply to the following RF programs: RFOPS (Outbound Process Scan), RFIPS
(Inbound Process Scan) and UOPR (Update Order Process).
In addition to the normal setups for catch weights in IPRO and IPRP, you must enter a value in the Weight
Tolerance Percent field in Quantity Breakdown Block of ITEM for the appropriate SKU.
You enter process values in RFOPS. There are two process values that you enter in this program: catch
weight and serial number. You can scan a bar code that contains these two values or you can enter them
manually.
RFOPS maintains a running total by both weight and number of pieces. The running total shows the weight
and number of pieces that have been scanned in as well as the weight and number of pieces that have not
been scanned in.
If a label has been scanned in error, you can remove it by means of the Remove command. If a case has
been scanned in error, you can remove it from the remaining number of cases to be scanned by means of the
Reduce command.
R EQU IR E M E N T S
R EQU IR E M E N T S
PROCESS VAL- For the UCC-128 label, you require two process values in RFOPS: one for catch
UES weights and one for serial numbers. These codes must be set up in IPRO (Item
Process) with the Create Automatic Records flag set to Y for Yes and then
attached to a profile in IPRP (Item Process Profile). The IPRP profile must in turn
be attached to the item(s) requiring the process values.
Because you are capturing a weight, the item(s) should assigned the appropriate
non-standard weight option in ITEM.
See the section “Item Process Values” in the Operations 2 Guide for further infor-
mation about process values.
SCAN PARAME- You need a scan parameter profile defined in SCPR (Scan Parameter Code)*.
TER CODE For the UCC-128 label, this profile must contain a minimum of two records in the
Detail Block: one record for your scanned in weight and another record for your
scanned in serial number. The SCPR profile must in turn be attached to the item
requiring the process values.
If you wish to scan in your lowest inventory level as a unique identifier, you must
define your scan parameters in SCPR and attach your scan parameter code to
your bar code profile in BAPR (Bar Code Profile).
BASE FOR CUBE/ The Base for Cube/Weight flag for your case SKU in the Quantity Breakdown
WEIGHT Block of ITEM must be set to Y for Yes for any product that you wish to process in
RFOPS.
CATCH WEIGHT See “Setting Up Catch Weight Tolerances” on page 259 for further information.
TOLRANCES
SORT SEQUENCE You can define a sort sequence for your process values in the RFOPS Sort
CODE (SOSE) Sequence Code (SOSE) field in MRFP.
OTHER If you pick product in RFPIC, you can only enter process values in RFOPS after
picking in RFPIC. If you pick product in any other program, you can enter process
values either before or after picking.
RFOPS supports alternate item codes set up in ALIT (Alternate Item and Lan-
guage).
FUNCTION KEYS
All Modes
1 Enter RFOPS.
RFOPS screen
If you wish to process a If you wish to process a spe- If you wish to process a
specific order: cific order and a specific UI: specific UI:
a) Press F9 to position your cur- a) Press F9 to position your cur- a) Enter or scan in your UI value.
sor in the ORD field. sor in the ORD field.
b) Key in your order number and b) Key in your order number and
press Enter. press Enter.
c) Enter or scan in your UI value.
AccellosOne 3PL will retrieve all order lines that match the criteria that you entered.
Line 1
Line 2
3 Use your arrow keys to position your cursor over the order line that you wish to process and press F3
(SL) to select it.
5 Continue to scan all pieces on the order line. If the same item is found on two or more order lines, Accel-
losOne 3PL will calculate a running total of the weight for all order lines containing that item.
6 When you finish entering all your order lines, process another order line or press F4 to exit.
IPRO screen showing Locate Weight in Bar Code Dynamically flag set to Y for Yes
The operator scans in the full bar code and then manually enters the weight for the first three cartons. If the
manually entered weight matches the bar code weight in all three cartons on the same order line, Accel-
losOne 3PL “learns” the position of the weight in the bar code.
If the manually entered weight does not match the bar code weight, the operator will be prompted to either
start over again or rescan the current carton.
EXAMPLE
9991234999 (Label 1)
9991356999 (Label 2)
9991426999 (Label 3)
Because the position of the weight in label one (positions 4 through 7) matches the position of the weight in
labels two and three, AccellosOne 3PL will read the weight from these positions for all pieces on the order
line.
If the same bar code is scanned twice, the operator will have two choices: accept the duplicate or enter a new
bar code.
1 Enter RFOPS.
2 Do one of the following:
If you wish to process a If you wish to process a spe- If you wish to process a
specific order: cific order and a specific UI: specific UI:
a) Key in your order number and a) Key in your order number and a) Press Enter to bypass the
press Enter. press Enter. Order Number field.
b) Press Enter to bypass the UI b) Enter or scan in your UI value. b) Enter or scan in your UI value.
field.
AccellosOne 3PL will retrieve all order lines that match the criteria that you entered.
Line 1
Line 2
3 Use your arrow keys to position your cursor over the order line that you wish to process and press F3
(SL) to select it.
4 Key in your weight unit of measure (1 for kilograms or 2 for pounds) and press Enter. If you made a mis-
take and wish to select another order line, key in 3 for Cancel and press Enter.
6 Key in the weight and press Enter. The weight must include a decimal point. For example, to enter a
weight of 20 pounds, you must key in either 20.0 or 20.00. You cannot key in 20.
7 Repeat steps 5 and 6 for your second piece.
8 Do one of the following:
If the position and weight of label If the position and weight of label
1 matches label 2: 1 does NOT match label 2:
a) Repeat steps 5 and 6 for your AccellosOne 3PL will offer you two
third piece. options: you can either start over
again from the first scan or repeat
the second scan.
If the position and weight of label If the position and weight of label
3 matches labels 1/2: 3 does NOT match labels 1/2:
The following message may AccellosOne 3PL will offer you two
appear: options: you can either start over
again from the first scan or repeat
the third scan.
Line #
11 Continue to scan all pieces on the order line. If the same item is found on two or more order lines, Accel-
losOne 3PL will calculate a running total of the weight for all order lines containing that item.
12 When you finish scanning all your pieces, process another order line or press F4 to exit.
1 The following message will display when there is no match between the manually entered weight and the
bar code weight in two out of three labels:
3 Manually key in the weight of the first piece and press Enter.
4 Repeat the previous step for each piece on the order line.
5 When you finish entering your weights manually, press F4 to exit.
1 Enter RFOPS.
2 Enter or scan in your order number and/or UI number.
3 Use your arrow keys to position your cursor over the order line that you wish to process and press F3
(SL) to select it.
4 Press F3 (RL).
1 Enter RFOPS.
2 Enter or scan in your order number and/or UI number.
3 Use your arrow keys to position your cursor over the order line that you wish to process and press F3
(SL) to select it.
4 Press F2 (RC).
5 When prompted to remove the case and reduce the line quantity, key in Y for Yes and press Enter.
a) Enter or scan in the case that a) Press Enter to position your cur-
you wish to remove. sor in the REDUCE QTY field.
b) Key in the quantity to remove
and press Enter.
7 When the “Unit removed” or “Unscanned quantity reduced” message appears, press Enter to confirm it.
8 Continue to scan in or remove cases in the normal manner or press F4 (EX) to exit.
1 Enter RFOPS.
2 Key in your order number and press Enter.
3 Enter or scan in your UI value.
RFOPS screen showing prompt to remove case and reduce line quantity
5 Use your arrow keys to position the cursor over the order line containing the case(s) that you wish to
remove and press F3 (SL) to select it.
7 When the “Unit removed” message appears, press Enter to confirm it.
8 Do one of the following:
a) Proceed to next step. a) Enter or scan in your label a) Press F4 (Ex) to position your
number. cursor in the Ord. field and
press Enter.
b) Enter or scan in your new UI
value.
c) Enter or scan in your label
number.
9 When you finish scanning the cases to be removed, press F4 (RT) and F4 (EX) to exit.
3 (Exit, Short) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned and
remove unscanned quantities from the to ship quantity.
You cannot process the order line again in RFPIC.
4 (Exit, New Line) Only available when locate weight in bar code logic is
deactivated
7 (Exit Scan, Save) Cease scanning and exit. AccellosOne 3PL will save
the process values of any cases already scanned.
1 Scan all cases that you are shipping for the pallet. The system will prompt you when you are complete.
2 If you are unable to scan all cases for any reason, press F4 after scanning the last scannable case.
If you wish to exit and short the Key in 3 and press Enter.
to ship quantity: When prompted to short the order line, key in Y for Yes
and press Enter.
You cannot transfer process values if one or more values is missing. For example, if you have five cases
on one full pallet and one of the cases is missing a process value, you cannot transfer the process val-
ues in RFOPS. You must enter the missing catch weight(s) in ENOR and then return to RFOPS to per-
form the transfer.
You cannot transfer process values if you have two or more inventory entities that are identical. For
example, you have two pallets with the same level 1/2/3 values and you wish to ship out a single pallet.
Unless you are clearing out all inventory, the quantity being shipped must always equal one full pallet (or
one drum if drum is assigned to the highest SKU class). For example, if you ship in cases, the number of
cases that you ship must equal one full pallet.
Refer to the section “Item Process Values” in the Operations 2 Guide for further information about setting up
this feature.
1 Enter RFOPS.
2 Retrieve the order whose process values you wish to transfer.
The “Barcode values for this order have transferred” message will appear.
RFOPS screen showing “Barcode values for this order have transferred” message
You pick your waves in RFPK (RF Wave Pick). Depending on your pick method, you may or may not be
prompted to for a carton size when you close your pallet and prepare to print your labels. You can look up
your carton information in LOCN (Look Up Carton).
R EQU IR E M E N T S
FLOWS See “Picking Orders in RFPIC” on page 199 for further information.
CASE PICKING See “Picking Orders in RFPIC” on page 199 for further information.
PROCESS VALUES See “Picking Orders in RFPIC” on page 199 for further information.
SUSP HOLDS See “Picking Orders in RFPIC” on page 199 for further information.
R EQU IR E M E N T S
MRFP The Outbound Pallet ID Entry at Beginning field in MRFP (RFPIC 2 tab) must
be set to Yes.
LABELS You need a wave label set up in DOCU and this label must be attached to the
appropriate customers and consignees in CCDU (Customer / Consignee Doc-
ument Setup).
1 Enter RFPK.
RFPK screen
RFPK screen
4 Key in the number corresponding to your pick method and press Enter.
6 Use your up and down arrow keys to scroll through the list of order lines assigned to your outbound pallet
ID. When you find the order line that you wish to pick, press F3 (SL) to select it.
a) Proceed to next step. AccellosOne 3PL will display the AccellosOne 3PL will display the
list of unpicked order lines. list of unpicked order lines.
a) Select the line that you wish to a) Press F4 to exit the list.
pick and repeat steps 6 to 12 b) Proceed to next step.
for that line.
a) Press Enter to generate your a) Enter or scan in your pallet ID. a) If the PRT (Printer) field is not
pallet ID. b) If required, key in your printer populated, key in your printer
b) if required, key in your printer code and press Enter. code and press Enter.
code and press Enter.
c) If prompted to validate your
pallet ID, enter or scan it in.
In this program, you can relocate product on an outbound order. The product must be picked and assigned an
outbound pallet ID in an RF picking program before it can be moved.
R EQU IR E M E N T S
FLOWS See “Picking Orders in RFPIC” on page 199 for further information for your
outbound flows and other RFPIC requirements.
The order line must be picked in an RF picking program using CASE pick
mode before it can be relocated in RFST.
OTHER There are five possible configuration parameters for RFST that you set up in
MRFP (Miscellaneous tab).
in the Validate Quantity in Order Move field, you specify whether or not the
operator must enter the quantity being moved
in the Validate From Location in Order Move field, you specify whether or
not the operator must enter the from location of the product being moved
in the Location Type of To Location in Order Move field, you specify whether
the to location must be a staging location, a pick location or any location
in the Allow Multiple Pallet Moves in RFST field, you specify whether or not
the operator can relocate multiple pallets in the same location in a single
step
in the Suggested Location Rules in RFST field, you define the suggested or
default to location
1 Enter RFST.
RFST screen
2 Enter or scan in your order number. Then enter or scan in your OPID number. If your OPID numbers are
unique, you can bypass the order number and enter only the OPID number.
3 If prompted to enter the quantity, key in the total quantity on the pallet and press Enter.
4 If prompted to enter the from location, enter or scan in the from location.
You can merge two or more outbound pallets into a single pallet in RFMG. For example, suppose you pick 10
cases from a location and build an outbound pallet. Later, you pick 25 cases from the same location and build
a second outbound pallet. You now have two partial pallets and wish to merge the two into a single pallet to
save space.
If your order line does NOT have process values such as serial number or weight, you can merge the entire
quantity of a pallet or a partial quantity. However, if your order line has process values such as serial number
or weight, you cannot merge partial quantities. If you do so, all process values attached to the order line will
be deleted.
The following conditions must be met before you can do a pallet merge:
The product must be picked from the same location.
If you attach orders to loads in SELO and warehouse attribute 333 is set to 1, the product being merged
must be on the same load and assigned to the same stop and group.
Hazardous products cannot be merged with non-hazardous products.
The same item must be kept together whenever possible if the item quantities are partials. For example,
suppose you have three OPID’s on the same order and each OPID represents a partial pallet. If OPID’s
1 and 2 are the same item and OPID 3 is a different item, OPID’s 1 and 2 can be merged, but 1 and 3 (or
2 and 3) cannot be merged because that would put two different items on the same pallet.
There are two merge options that are configurable in MRFP:
F I E L D D E S C R I P T I O N S ( MI S C E L L A N E O US 2 / 5 TA B)
F I E L D D E S C R I P T I O N S ( MI S C E L L A N E O US 2 / 5 TA B)
If you select Yes, the OPID to value remains displayed on the screen after the
merge so that the RF operator can continue to merge into the same OPID.
1 Enter RFMG.
3 If there are multiple order lines attached to the same OPID, you can press F1 (LN) to position your cursor
in the from OPID block. Then use your arrow keys to scroll through the orders lines of your from OPID.
When you finish scrolling, press F4 (RT) to return to the to OPID field.
4 Press Enter to accept the full OPID quantity or key in a partial quantity and press Enter.
5 Enter or scan in your to OPID.
1 Enter RFMG.
3 If there are multiple order lines attached to the same OPID, you can press F1 (LN) to position your cursor
in the from OPID block. Then use your arrow keys to scroll through the orders lines of your from OPID.
When you finish scrolling, press F4 (RT) to return to the to OPID field.
4 Press Enter to accept the full OPID quantity or key in a partial quantity and press Enter.
5 Enter or scan in your new OPID.
This program allows you to perform an audit of staged product before it is loaded onto the truck. You define
your inventory level for RFOA audits in MRFP. For example, if you select Level 1 in the RFOA Audit Level
field, the RF operator will perform a count for each item on the order. If, on the other hand, you select Level 2,
the RF operator will perform a count for each lot on the order.
If the count matches the order line quantity, the order line will be advanced to the next flow and a time-stamp
will be created indicating that the audit was successful. If the count does not match the order line quantity, an
error message will be displayed and the order line will not be advanced to the next flow.
R EQU IR E M E N T S
R EQU IR E M E N T S
OTHER You must define your inventory level for RFOA audits in the RFOA Audit Level
field in MRFP. For example, if you select Level 1 in the RFOA Audit Level field,
the RF operator will perform a count for each item on the order. If, on the other
hand, you select Level 2, the RF operator will perform a count for each lot on the
order.
If you select “Suspend Advancing Flow in Outbound Audit” in MRFP, the order will
NOT be advanced to the next flow even if the operator count matches the order
line quantity.
1 Enter RFOA.
RFOA screen
8 Repeat the above steps for any additional order lines that you wish to audit or press F4 the required num-
ber of times to exit RFOA.
Refer to the Operations 2 Guide for instructions on using SELO and OLOP.
You relocate inventory from one location to another in RFRL. The locations that you specify in a relocate can
be within the same warehouse or belong to different warehouses. You cannot relocate inventory if it is on
order or on receipt.
The following restrictions apply to RFRL:
You cannot relocate product that is on an open order or receipt.
Relocating inventory does not take into account the location’s capacity. You can move inventory into a
location that is considered “full”.
If the product is on non-breakable hold, you must relocate all product in the location; you cannot relocate
partial quantities.
If you wish to relocate product to a pick line location, you must set the Validation Rules for Relocate to Pick
Line flag in MRFP to either 2 (Allow operator to proceed) or 3 (Omit validation of location).
R EQU IR E M E N T S
ALLOCATION If you want AccellosOne 3PL to select the best possible to location for a reloca-
tion based on your directed move stock parameters in ILOP, you must set the
Allow Directed Move in RF Relocate flag in MRFP to Yes.
See the Allocation and Wave Manager Guide for further information on setting up
directed moves.
OTHER If you want the operator to be forced to validate the from location in a relocation,
you must set the Picklist Rules in RF Relocate flag in MRFP to the appropriate
value.
If you want relocation quantity to be displayed, you must set the Display From
Relocation Quantity in RF Relocate flag in MRFP to Yes.
FUNCTION KEYS
Criteria Mode
FUNCTION KEYS
Results Mode
1 Enter RFRL.
RF — Relocate
3 The system will display the number of inventory records that meet the level 1, 2, 3 and 4 criteria that you
specified.
Number of records
for this inventory
entity
RFRL screen showing one record for item A2, lot 101
a) Key in your from location and a) Press F10 to enter the pick list,
press Enter. then F2 to perform your query.
AccellosOne 3PL will display all locations
containing the product that you specified.
a) If you wish to relocate all product a) Key in the quantity that you wish
in the location, proceed to the to relocate and press Enter.
next step. If you wish to relocate
a portion of the product in the
location, press F9 to position
your cursor in the QTY field.
Then key in your relocation
quantity and press Enter.
1 Enter RFRL.
RF — Relocate
3 The system will display the number of inventory records that meet the level 1, 2, 3 and 4 criteria that you
specified.
Number of records
for this inventory
entity
RFRL screen showing six records for item A2, lot 101
a) Key in your from location and a) Press F10 to enter the pick list,
press Enter. then F2 to perform your query.
AccellosOne 3PL will display all locations
containing the product that you specified.
a) If you wish to relocate all product a) Key in the quantity that you wish
in the location, proceed to the to relocate and press Enter.
next step. If you wish to relocate
a portion of the product in the
location, press F9 to position
your cursor in the QTY field.
Then key in your relocation
quantity and press Enter.
You can adjust in and adjust out non-serial number inventory in RFAJ without the need to enter ENAJ (Enter
Adjustment). In RFAJ you can perform most of the functions supported in ENAJ including:
querying by any inventory level
entering positive and negative adjustments for existing inventory
creating new inventory
When adjusting existing inventory, you can enter either partial or full amounts of an inventory entity. When
creating new inventory, you can specify a hold code, enter a variable quantity breakdown (if this feature is
activated in ITEM) and enter an expiry date (if expiry date entry is activated in ITSH).
RFAJ does not support adjustment transfers, changes to an item’s quantity breakdown or changes to a level
2/3/4 description. These functions must be performed in ENAJ.
FUNCTION KEYS
Main Mode
Results Mode
1 Enter RFAJ.
RFAJ screen
2 Enter your UI or inventory levels and press Enter. If the same inventory is found in multiple locations, you
must enter or scan in your location.
If you do not know the UI or inventory levels of the inventory that you wish to adjust out, press Enter twice
to position your cursor in the L1 field. Then enter the inventory level(s) that you know and press F2 (QU).
When AccellosOne 3PL retrieves the list of query results, use your up and down arrow keys to scroll
through the list.
3 If the inventory has been assigned multiple locations, use your up and down arrow keys to find the loca-
tion that you want to adjust out. The press Enter to accept it.
4 Enter or scan in your location.
5 Key in your adjust out quantity as a negative (for example, -1 or
-1PLT) and press Enter. If the item has multiple SKU’s in its quantity breakdown and you do not specify
a SKU, AccellosOne 3PL will use the item’s lowest SKU.
1 Enter RFAJ.
RFAJ screen
5 Enter the remaining inventory levels of the inventory that you wish to adjust in.
6 If you wish to place the adjust in inventory on hold, press F1 (HD). Then key in your hold code and press
Enter.
7 Press F3 (PR) to process.
If the location that you enter If the location that you enter
does NOT match the location in does match the location in step
step 3: 3:
9 Key in your adjust in quantity (for example, 1 or 1PLT) and press Enter. If the item has multiple SKU’s in
its quantity breakdown and you do not specify a SKU, AccellosOne 3PL will use the item’s lowest SKU.
1 Enter RFAJ.
RFAJ screen
4 Enter the remaining inventory levels of the inventory that you wish to adjust in.
5 Press F2 (CM).
10 If the location that you entered in the previous step does not match the location in step 3, the following
message will display:
If the location is correct, key in Y for Yes and press Enter to accept it. Otherwise, press Enter to reject it.
11 Key in your adjust in quantity (for example, 1 or 1PLT) and press Enter. If the item has multiple SKU’s in
its quantity breakdown and you do not specify a SKU, AccellosOne 3PL will use the item’s lowest SKU.
You can adjust in and adjust out serial number inventory in RFAJB. RFAJB performs the adjustment to
inventory and the bar code validation at same time. It can only be used with unique serial numbers.
You can adjust in inventory when the serial number has never been received or is on a confirmed order. If
required, adjusted in inventory can be placed on hold. You can adjust out inventory when the serial number
has been received and is not picked. If a case is on a full pallet and all cases are available, you can adjust out
a full pallet by scanning in a single case.
RFAJB can also recover from a lost connection. When a connection is dropped, you can either finish the
current transaction or continue to adjust in or adjust out more cases.
R EQU IR E M E N T S
PROCESS VAL- You require two process values: one for catch weights and one for serial num-
UES bers. These codes must be set up in IPRO (Item Process) as follows:
Then attach your process values to a profile in IPRP (Item Process Profile). The
IPRP profile must in turn be attached to the item(s) requiring the process values.
See the section “Item Process Values” in the Operations 2 Guide for further infor-
mation about process values.
SCAN PARAME- You need a scan parameter profile defined in SCPR (Scan Parameter Code).
TER CODE This profile must contain a minimum of three records in the Detail Block: one
record for your scanned in weight, a second record for your scanned in serial
number and a third record for your scanned in inventory level 1 value. The SCPR
profile must in turn be attached to the item requiring the process values.
BAR CODE PRO- You must define a bar code profile in BAPR and attach to it the scan parameter
FILE code that you set up in SCPR.
OTHER You need a default adjustment code in ATMP (Action Template Setup) for each
company/customer combination. If a single default adjustment code for all cus-
tomers in all companies, you can use the .ALL codes for both customer and com-
pany.
FUNCTION KEYS
All Modes
ADJUSTING IN INVENTORY
You can adjust in inventory when the serial number has never been received or the product is on a confirmed
order.
1 Enter RFAJB.
RFAJB screen
5 Repeat the above step for each additional case that you wish to adjust in.
6 If you make a mistake and wish to “unscan” a scanned case, press F2 (RM). Then rescan the case to be
removed from the adjustment.
7 When you finish scanning the cases to be adjusted in, press F3 (PR).
RFAJB screen showing warning that serial number has already been received
12 Press F4 to exit.
1 Enter RFAJB.
RFAJB screen
5 Repeat the above step for each additional case that you wish to adjust out.
6 If you make a mistake and wish to “unscan” a scanned case, press F2 (RM). Then rescan the case to be
removed from the adjustment.
7 When you finish scanning the cases to be adjusted out, press F3 (PR).
1 Enter RFAJB.
RFAJB screen
5 Press F1 (PLT).
8 Key in the total number of cases on the pallet and press Enter.
9 Press F4 to exit.
1 Enter RFAJB.
4 Press F1 (PLT).
10 Key in the total number of cases being adjusted out — that is, the number of cases on the pallet that you
did NOT scan — and press Enter.
For example, if your pallet quantity breakdown is 20 cases per pallet and you use the Remove command
to remove five cases, your adjust out quantity will be 15 (20 -5).
11 Press F4 to exit.
1 Enter RFAJB.
If you wish to finish the existing If you wish to add more cases to
adjustment: your adjustment:
You can merge and transfer inventory entities in RFMI. You use RFMI when you wish to consolidate two
partial pallets into a single PID or you wish to correct an incorrect inventory level. For example, you received
product under lot number 101, which is wrong, and you want to transfer the product to lot number 102, which
is the correct lot number. Lot 102 can be either an existing lot number or a new lot number created by the
operator in RFMI.
The following requirements must be met before you can merge/transfer inventory in RFMI:
the product belongs to the same customer
the customer is billed at the lowest inventory level in DILP
the product is NOT on an open order or receipt
If you have assigned process values to your product and if you are merging or transferring a full pallet, no
scanning of process values is required as the values are transferred automatically. If, however, you are
working with less than a full pallet, process values must be individually scanned.
R EQU IR E M E N T S
SCAN PARAME- If you use process values to capture catch weights and serial numbers, you need
TER CODE a scan parameter profile defined in SCPR (Scan Parameter Code). This profile
must contain a minimum of three records in the Detail Block: one record for your
scanned in weight, a second record for your scanned in serial number and a third
record for your scanned in inventory level 1 value. The SCPR profile must in turn
be attached to the item requiring the process values.
INVENTORY LEV- You can merge inventory entities at inventory levels other than the lowest (PID)
ELS by setting the Allow Merging Up To Level (RFMG) field in MRFP to the appropri-
ate value: Level 1, Level 2 or Level 3.
INVENTORY If your inventory entities have inventory attributes set up in IAPR (Inventory Attri-
ATTRIBUTES butes Profile Code), you cannot perform a merge unless there is an exact match
of attributes (you can deactivate this condition by selecting the Allow RF Merge
flag in IAPR).
VARIABLE QUAN- The Base for Cube/Weight flag in ITEM must be set to Y for Yes for the lowest
TITY BREAK- SKU.
DOWN
INVENTORY
OTHER You need a default adjustment code in ATMP (Action Template Setup) for each
company/customer combination. If a single default adjustment code applies to all
customers in all companies, you can use the .ALL codes for both customer and
company.
R EQU IR E M E N T S
ATMP screen showing default adjustment code for all companies and custom-
ers
1 Enter RFMI.
RFMI screen
If you know the UI of the adjust in If you do NOT know the UI value
inventory: of the adjust in inventory:
If you know the UI of the adjust If you do NOT know the UI value
out inventory: of the adjust out inventory:
5 If the inventory entity that you entered in the previous step is found in multiple locations, use your arrow
keys to select the correct record.
6 Key in your adjustment quantity as a negative value and press Enter.
8 If you want to place the merged inventory on hold, press F9 to position your cursor in the H field. Then
key in your hold code and press Enter.
9 Key in the total number of cases and press Enter. For example, if you are merging 5 cases of pallet ID
101 with 10 cases of pallet ID, your total number of cases will be 15 (5 + 10).
10 Press F4 (EX) to exit.
1 Enter RFMI.
RFMI screen
If you know the UI of the adjust If you do NOT know the UI value
out inventory: of the adjust out inventory:
7 If you want to place the new inventory on hold, press F9 to position your cursor in the H field. Then key in
your hold code and press Enter.
8 Enter or scan in the location of the new inventory.
9 Press F4 (EX) to exit.
If RF entry of extra charges is activated in ECHP, you can add extra charges to receipts or orders in the stand-
alone program RFEC. You can also add extra charges to receipts or order in RFCH (receipts only) or RFPIC
(orders only).
The entry of extra charges in RFEC/RFCH/RFPIC is strictly optional. You can press F4 at any time to exit the
program without entering an extra charge.
There are two possible scenarios for extra charge entry in RFEC: you can select your extra charge(s) from a
predefined list or you can manually enter them.
FLOWS The receipt or order must be at the flow set up for extra charge entry in ECHP. If
the Flow Process Code (FLPR) for RF field in ECHP is blank, you can add extra
charges to a receipt or order at any flow.
There are two flags in ECHP that govern extra charge entry in RF: Allow RF Entry and Allow Override of
Charge Quantity in RF. If both flags are set to N for No, extra charge entry in RF is deactivated.
1 Enter RFEC.
RFEC screen
4 If you change your mind and do not wish to add an extra charge to the receipt or order, press F4 (RT) and
F4 (EX) to exit RFEC.
5 If there are multiple extra charges in RFEC, use your arrow keys to scroll up and down the list until you
find the extra charge that you wish to add.
6 Key in your charge quantity and press Enter. A charge quantity of zero means no extra charge for the
receipt or order.
RFEC screen showing prompt to confirm the change to the charge quantity
a) Key in Y for Yes and press Enter. a) Press Enter to accept the default
value of No.
8 Repeat the previous steps for each additional extra charge that you wish to add to the receipt or order.
9 When you finish adding your extra charges, press F4 (RT) and F4 (EX) to exit.
1 Enter RFEC.
RFEC screen
6 Key in your charge quantity and press Enter. If you press Enter to accept the default quantity of zero, no
extra charge will be created for the receipt or order.
7 Repeat the previous steps for each additional extra charge that you wish to add to the receipt or order.
8 When “RF Charges Completed” message appears, press Enter to acknowledge it.
9 Press F4 (EX) to exit.
1 Enter RFEC.
2 Key in I for Inbound or O for Outbound and press Enter.
You can define check digits for your locations and require RF operators to scan in this check digit from a label
attached to the location whenever they work in RFRL, RFPU, RFPIC and RFRP. The purpose of check digit
scanning is to ensure that the RF operator physically went to the location to scan it rather than manually
entering any location at the dock.
You can use the program RFCD (RF Check Digit) to assign a check digit to an individual location or to a range
of locations. If your locations already have check digits, you can use RFCD to update them.
You use the “%” character as a wildcard when you wish to update a range of locations.
TIP You can look up and update location check digits in LOCA (Locations). How-
ever, unlike RFCD LOCA does not allow you to update a range of locations in a single
step.
R EQU IR E M E N T S
WAREHOUSE AND Check digit scanning must be activated in WARE by selecting the Manual Check
LOCATION FOR- Digit 1 option in the Voice Check Digit Usage field.
MAT
1 Enter RFCD.
RFCD screen
AccellosOne 3PL will retrieve all locations whose code matches the search criteria that you entered. If
there is currently a check digit assigned to the location(s) retrieved, it will display in the Check Digit field.
If your query retrieved a singe If your query retrieved multiple If you used the wildcard “%” in
location: locations: your query:
a) Proceed to next step. a) If required, you can use your a) If required, you can use your
up and down arrow keys to up and down arrow keys to
scroll through the list of loca- scroll through the list of loca-
tions to be updated. tions to be updated.
b) Press Enter to position your b) Press Enter to display the fol-
cursor in the Check Digit field. lowing message:
4 Key in your new check digit over the existing check digit (if any) and press Enter. When you press Enter,
all records that you retrieved in RFCD are updated with the new check digit.
5 Press F4 twice to exit RFCD.
You can track ad-hoc labor activities that occur while working in RF in RFINC (RF Incidents). For example, a
pallet is poorly stacked and falls over, a battery change is required for a forklift or a worker goes on break. If
required, you can invoice the activity to a customer and add a free-text comment.
The elapsed time of the incident is tracked by comparing the start time to the end time; that is, the time that
the incident was opened versus the time that you exit RFINC.
RFINC can be run directly from the menu or can be initiated from RFPIC, RFPU. RFCH and RFRL by
pressing the F5 function key.
R EQU IR E M E N T S
CUSTOMER RELA- If the incident’s job type in JBTP is attached to a CRM code, RFINC will create a
TIONSHIP MAN- CRME record for the incident.
AGEMENT
See the labor tracking section of the Operations 2 Guide for further informa-
tion on job types.
BILLING If an incident’s job type in JBTP is attached to a charge code and you select the
invoice to customer option, RFINC will create an accessorial charge for the inci-
dent.
See the labor tracking section of the Operations 2 Guide for further informa-
tion on job types.
1 Enter RFINC.
RFINC screen
3 Use your up and down arrow keys to position the cursor over the job type that you wish to select. Then
press F3 (SL) to select it.
4 Key in the quantity of product involved in the incident and press Enter.
5 Key in the quantity's SKU code and press Enter.
If you wish to charge for the If you do NOT wish to charge for
incident: the incident:
7 Key in your message code for the incident and press Enter or use the pick list function to select your
message code.
8 If your job type is attached to a CRM code, you can key in free-text comment in the Comment field. This
comment will appear in the Description field of CRME.
9 When you finish entering your incident, press F1 (PR) to process.
If a CRM (Customer Relationship Management) task has been assigned to you in CRME (CRM Entry), you
will be prompted to perform the task whenever you log on to RF or exit an RF program. You can also access
your CRM tasks directly in the program RFCE (RF CRM Entry).
CRM tasks remain assigned to you until you close them. When you close a CRM task, you can add a free-text
comment to it or you can close the task without adding a comment.
CRM entry in RF does not support labor tracking.
1 Enter RFCE.
a) Key in your comment and a) Press F3 (PR) to process the a) Press F4 (EX) to exit without
press Enter. task. closing the CRM task.
b) When prompted to close the b) When prompted to close the
task, key in Y for Yes and task, key in Y for Yes and
press Enter. press Enter.
c) Press Enter to continue when c) Press Enter to continue when
the CRM Closed message the CRM Closed message
appears. appears.
This program allows you to scan in any bar code to find out the number of empty spaces between each
segment. Empty spaces are indicated by hyphens.
1 Enter RFBR.
RFBR screen
3 Press F4 (RT)
4 Press F4 (EX) to exit.
Overview
Voice-activated picking using Vocollect Voice allows you to perform easy, hands-free picking. You can set up
voice profiles defining various Vocollect Voice options and attach these profiles to task profiles that define
which customers, carriers, consignees, items, orders, locations and warehouses can be picked. If required,
voice-directed picking can be combined with scanning when certain inventory levels are too long to be
spoken.
You can also define voice operator overrides that temporarily override an operator’s standard task profiles in
order to perform work that is particularly urgent.
The order assignment system allows you to assign specific orders and/or order lines to specific operators and
define a picking sequence for each order. When the designated operator enters RFPIC, only orders assigned
to that operator will display in the pick list. If required, an operator can cancel order assignments in RFPIC;
when this happens, the order line appears in the pick list of all RF operators.
The order assignment system shares two voice-activated picking programs — RFOP and RFOT — but does
not use voice profiles defined in VOPR and VOPC.
whether or not the operator will be prompted with the delivery location
the number of digits in a work ID
FIELD DESCRIPTIONS
Description Mandatory
If you select Operator requests work, the operator will be prompted to read out
the order number that he or she wishes to pick. If you select System assigns
operator assignment, assignments are automatically assigned to operators
and no order number is required.
In this field, you specify which inventory levels (if any) the operator will hear
from Vocollect Voice for each pick.
In this property, you specify whether or not you want AccellosOne 3PL to
prompt the operator for the delivery or staging location and whether or not you
want the operator to confirm the delivery or staging location.
If the order has been assigned an appointment, AccellosOne 3PL will use the
appointment’s door/location as the delivery location. If the order has NOT
been assigned an appointment, AccellosOne 3PL will use the staging location
in the operator’s task profile.
The operator can override the delivery location by saying “override”. The sys-
tem will ask him or her for a new location. From that time on, the new location
will be used for the next delivery until the operator overrides it again.
FIELD DESCRIPTIONS
Work ID Length The number of digits in a work ID. If an operator provides a work ID with fewer
than this number of digits, it will be rejected by AccellosOne 3PL.
If you enter the value -1, the operator must provide the entire work ID number.
Assignment Message If populated, this field will be read out to the voice operator for each assign-
ment that he or she is going to work on. This is the default message. It will not
be read out if there are higher level assignment messages that replace the
VOPR default message. There are four possible higher level assignment mes-
sages:
1) pallet code description will be read out if a pallet code is attached to the
CONS record for the order
2) message code description will be read out or added to the above if a mes-
sage code is attached to the CONS record for the order
3) message code description will be read out or added to the above if a mes-
sage code is attached to the order header
4) appointment time and door number will be read out or added to the above
if an appointment is attached to the load of the order
1 Enter VOPR.
VOPR screen
2 Click on Create.
3 Key in your voice profile code and press Enter.
4 Key in a description for your new code and press Enter.
5 Click on Save.
6 Proceed to select the appropriate option for each property by either selecting the option from a dropdown
list or by keying in a value.
FIELD DESCRIPTIONS
Description Mandatory
In this property, you specify whether or not you want AccellosOne 3PL to pro-
cess the data 1 value of product being picked. Data 1 can refer to any inven-
tory level. If you select the “Do not process data 1” option, AccellosOne 3PL
will specify a quantity and location for each pick, but no inventory levels.
FIELD DESCRIPTIONS
Do not speak the data 1 field but allow operator to enter confirmation
value
If you select this option, the data 1 value is not spoken but the operator must
confirm it. The value confirmed must match the product being picked or must
be a valid substitution product.
Data 1 Minimum Capture In this property, you specify the number of characters in the inventory level
Length that the operator must read out. For example, if you set this property to two,
the operator must read out the last two characters in the inventory level.
This value is a minimum only; if the inventory level has five characters and this
value is set to two, the operator can read out the last two characters, the three
last characters, the four last characters or all five characters. However, he or
she cannot read out the last character only as this value is less than the mini-
mum.
If you leave this field blank, the operator must read out all characters in the
inventory level.
FIELD DESCRIPTIONS
In this field, you activate cycle count countbacks for your voice customer. See
“Performing Count Backs in RFPIC” on page 221 for further information.
1 Enter VOPC.
VOPC screen
5 Click on Save.
6 Proceed to select the appropriate option for each property by either selecting the option from a dropdown
list or by keying in a value.
FIELD DESCRIPTIONS
Default Customer Voice The default customer voice profile for the task profile. This profile is used if the
Profile Code (VOPC) customer has not been assigned a voice profile in CUST.
The length of the UI check digit. For example, if you enter 3 in this field, the
operator must read out the last three digits belonging to the UI of the product
to picked in the location that the product is to be picked from.
For example, suppose the order line is picking item ABC001, pallet ID PA987
from location LA001. The voice terminal will read out the location code to the
operator. The operator will go to the location LA001, find pallet ID PA987 and
read out “987” to confirm that he or she has arrived at the location.
Spoken Length The length of the spoken portion of the OPID. This value is added to the OPID
prefix to form the full OPID for the order line being picked. AccellosOne 3PL
will validate this number to ensure that it is unique and has not been used
before.
Spoken Value Numeric If this field is checked, the value spoken by the operator must be numeric. If
this field is NOT checked, the value spoken by the operator can be alphanu-
meric.
1 Enter WARE.
2 Retrieve the warehouse that you wish to set up for manual check digits.
3 Press Enter until your cursor is positioned in the Voice Check Digit Usage field. Then select the appropri-
ate manual check digit option.
4 Depending on the option that you selected in the previous step, key in the days of week separated by
commas for each check digit and then press Enter. For example, to enter Monday, Wednesday and Fri-
day, you would key in MON,WED,FRI.
5 When you finish setting up your check digit parameters, click on Return to Main and Exit.
1 Enter LOCA.
2 Retrieve the location that you wish to assign a check digit to.
3 Key in your check digits for the location.
4 Repeat the above steps for any additional locations in the warehouse that require check digits.
5 When you finish assigning check digits to your locations, click on Return to Main and Exit.
FIELD DESCRIPTIONS
1 (Split-picking a Line)
This option is used for short picks; that is, the picker wishes to pick a partial
quantity from the location and return for the remaining quantity at a later time.
For example, if the pick quantity is five cases and the picker picks two cases,
AccellosOne 3PL will split the line into two lines. Line 1 (two cases) will be
marked as picked, while line 2 (three cases) will be marked as unpicked.
You must set up at least one reason code in order to voice pick in Vocollect
Voice.
Description Your description for the reason code. See Reason field.
The hold code that product is placed on when an order line cannot be picked.
1 Enter REAS.
2 Click on Create Record.
8 When you finish setting up your reason codes, click on Return to Main to exit create record mode.
9 Click on Exit to exit.
FIELD DESCRIPTIONS
FIELD DESCRIPTIONS
Location Code The location code of your voice terminal. The warehouse and location code
that you attach to a voice terminal in MHEC will be assigned to any product
picked using this voice terminal.
For example, if you assign staging location S100 to a given voice terminal and
then pick 10 cases of product using this terminal, AccellosOne 3PL will create
a record in the Location Block of LOEN showing 10 cases of product in loca-
tion S100.
1 Enter MHEC.
2 Click on New .
3 In the Equipment Code field, key in your Talkman terminal ID and press Enter.
4 Key in a description for your new terminal ID and press Enter.
5 In the Type field, key in TALK and press Enter.
6 Press Enter to bypass the Hourly Cost field.
7 Key in your warehouse code and press Enter or select it from the pick list.
8 Key in your staging type location code and press Enter or select it from the pick list.
9 Repeat the above steps for each additional voice terminal that you wish to activate.
10 When you finish adding your voice terminal(s), click on Save to save your changes.
If you do not want to pick certain orders using your voice-activated equipment, you can pick the orders in
RFPV (RF Picking Voice) using standard RF guns.
1 Enter RFPV.
8 If prompted to do so, key in or scan in the check digit for the location.
10 Press Enter to continue with the next pick or key in 2 and press Enter to exit RFPV.
If you use Vocollect Voice to pick your orders, you can temporarily override the orders in an operator’s
standard task profile(s) in order to give priority to orders that are particularly urgent. You define overrides by
selecting individual orders and order lines in RFOT and assigning them to the appropriate voice operator.
If you do not use Vocollect Voice and pick your orders in RFPIC, assigning operators to orders in RFOT will
reserve those orders/order lines for the designated operator in RFPIC. When the designated operator enters
RFPIC, only assigned orders for that operator will display in the pick list.
RFOT also allows you to define the picking sequence of orders assigned to a particular RF operator. If you do
not define a picking sequence, orders will be sequenced by order priority followed by order number.
1 Enter RFOT.
2 If required, click on the Pick/Interleave (2) tab.
3 Key in your filter criteria and click on Execute Query. AccellosOne 3PL will retrieve all order lines
that meet your filter criteria.
RFOT supports the following search criteria:
TODAY +1, etc. On orders with a to ship date of tomorrow (+1) or the day
before yesterday (-2)
4 If required, you can resort the order records in either ascending or descending sequence by clicking on
the appropriate header buttons (Order #, Customer, Consignee, To Ship Date, Flow or Cust. Order #).
5 If there is a line remark attached to the order line, click on Remarks to view it.
6 If you wish to assign order lines to an operator, click on the Lines tab.
7 Proceed to assign the orders/order lines that you want the operator to work on by one of the following
methods:
a) Select your operator from the a) Select your operator from the
Assign Operator dropdown list. Assign Operator dropdown list.
b) Click on the checkbox to the left
b) Click on Assign All.
of the operator code to complete
c) If you make a mistake and wish
the assignment.
to undo all assignments made in
8 If required, you can assign a sequence number to an order/order line and the order/order line must be
picked in that sequence. If you do not specify a sequence number, orders will be sequenced by order pri-
ority followed by order number.
1 Enter RFOT.
2 Click on Outbound Loads.
RFOT screen
3 Key in your filter criteria and click on Execute Query. AccellosOne 3PL will retrieve all loads that
meet your filter criteria.
RFOT supports the following search criteria:
TODAY +1, etc. On orders with a to ship date of tomorrow (+1) or the day
before yesterday (-2)
4 If required, you can resort the load records in either ascending or descending sequence by clicking on
the appropriate header buttons (Load #, Ext. Load #, Building, Door or Operator).
5 Proceed to assign the loads that you want the operator to work on by one of the following methods:
a) Select your operator from the a) Select your operator from the
Assign Operator dropdown list. Assign Operator dropdown list.
b) Click on the checkbox to the left
of the operator code to complete b) Click on Assign All.
the assignment. c) If you make a mistake and wish
to undo all assignments made in
6 If required, you can assign a sequence number to a load and the load will be picked in that sequence. If
you do not specify a sequence number, loads will be sequenced by order priority followed by order num-
ber.
1 Enter RFOT.
2 Click on Pick/Interleave (2).
3 Select your pick method from the Pick Method pick list.
1 Enter RFOT.
2 On the Filter window, key in the RF operator code of the operator whose assignments you wish to
remove and click on click on Execute Query. You can query by multiple operators by separating
each operator by a comma; for example, “BOB1,BOB2”.
RFOT screen showing three order lines assigned to the operator DALLEN
You can look up the current work assignments of your Vocollect Voice operators in CTPA (Clear Terminal Pick
Assignments). In the Detail Block of this program, you can clear all work assignments for a given voice
operator and make these work assignments available to another voice operator.
NOTE The Execute Query command in this program is limited to a screen refresh
only. It does not allow you to perform actual queries.
1 Enter CTPA.
2 Select the operator whose work assignments you wish to look up or clear and click on Detail Block.
4 Click on Exit.
Overview
Cartonization tab
F I E L D D E S C R I P T I O N S ( C A RTON I Z AT I O N )
F I E L D D E S C R I P T I O N S ( C A RTON I Z AT I O N )
Your picking path mode for the BATP and LABL pick methods in RFPK. See
“Task Profile (REGI)” on page 101 for a complete descriptions of picking path
modes.
Cartonization Sort The sort sequence or “snaking” of your pick locations for cartonization.
Sequence Code (SOSE)
If you select “Pick by Carton ID”, the RF operator will scan in the carton ID as
a confirmation step in RFPK. If you select “Pick by Carton Position”, the RF
operator will scan in the carton position on a cart or trolley as a confirmation
step in RFPK.
If you select “Sorted by Item”, the RF operator must scan in the item code in
RFSC. If you select “Sorted by Item/Level 2”, the RF operator must scan in the
item code plus level 2 value in RFSC. If you select “Sorted by Item/Level 3”,
the RF operator must scan in the item code plus level 3 value in RFSC.
In this program, you set up your carton size codes. Carton size codes are attached to customer/carrier/
consignee combinations in CCCC. For each carton size code, you define the following:
a carton size code and description
whether or not the carton’s dimensions/weight are inherited from the item’s dimensions and weight
if required, the linear measure code and the length/width and height
if required, the weight measure code, the maximum weight and the weight of an empty carton
the usable percentage of the cube
FIELD DESCRIPTIONS
Description Mandatory
Utilize Standard Configu- If you select this option, the carton dimensions/weight are inherited from the
ration item’s dimensions/weight in ITEM. If you do not select this option, you must
enter the carton’s dimensions/weight manually.
Linear Measure Code Only available if Utilize Standard Configuration is not selected
Length / Width / Height Only available if Utilize Standard Configuration is not selected
The carton’s actual cube calculated by multiplying the carton’s length, width
and height.
FIELD DESCRIPTIONS
Carton Size Cube Only available if Utilize Standard Configuration is not selected
In this field, you can define an override cube for a carton. For example, sup-
pose carton A has dimensions of 24 x 16 x 5 for a total of 1920 cubic inches. If
you define an override cube of 2500, you can place any number of items
whose total cube does not exceed 2500 cubic inches in this carton size.
Weight Measure Code Only available if Utilize Standard Configuration is not selected
Weight of Empty Carton Only available if Utilize Standard Configuration is not selected
Usable Percentage The usable percentage of the cube. The non-usable percentage is reserved
for packing materials.
Variable Dimensions If you select this option, the user will be prompted to enter the carton dimen-
sion in EPSD.
CTSZ screen
In this program, you set up your cartonization rules for different customer/carrier/consignee combinations.
FIELD DESCRIPTIONS
Customer Code The customer that the outbound process configuration applies to or.ALL for all
customers.
Carrier Code The carrier that the outbound process configuration applies to or.ALL for all
carriers.
Consignee Code The consignee that the outbound process configuration applies to or.ALL for
all consignees.
FIELD DESCRIPTIONS
Maximum Cube/Weight In these fields, you specify the maximum cube and weight for second level
cartonization. Second-level cartonization applies to product that cannot be
cartonized by the cartonization engine because it is oversized, has no ICNP
profile attached to it or has missing dimensions in ITEM.
Default Carton Size Code Your default carton size code in RFSC and second level cartonization.
(CTSZ)
If you select Give Priority to Carton Size Cube, the cube will be considered
first then the weight for second level cartonization. If, on the other hand, you
select Give Priority to Carton Size Dimensions, the weight will be considered
first then the cube.
Location Grouping
Material Handling Type Groups
Pickup and Delivery Groupings
Voice
In this field, you specify which zone type (if any) AccellosOne 3PL should look
at when comparing warehouse zones codes for the purposes of determining
the next pick location.
CCCC screen
In this program, you set up your packing stations. Packing stations are only required for manual packing in
EPSD. For each packing station, you define:
a packing station code and description
a material handling equipment code
the labels that will be printed at the packing station and the printers that they will be printed on
FIELD DESCRIPTIONS
Description Mandatory
FIELD DESCRIPTIONS
Your material handling equipment code for the packing station. The material
handling equipment code that you enter must be attached to a material han-
dling equipment type whose Location Required flag has been set to Y for Yes
because packing stations require a warehouse code and location code.
The location attached to the material handling equipment code in MHEC must
be a staging location.
In the Documents Block, you assign your labels to packing station printers.
In this program, you set up your item cartonization profile codes. Each profile code defines the factor to be
applied to a given set of items. For example, for your standard weight items, you set the factor to 1 for your
STD code in ICNP and attach STD to all standard weight items in ITEM. As for your non-standard weight
items, for each weight or cube category such as 1.15, 1.25, 1.35 times the standard weight or cube, you
attach the appropriate factor to a profile code.
For example, a fragile item like a teapot requiring a lot of extra packing materials might have a cube factor
of.85 meaning that 15% of each carton would be reserved for packing materials. On the other hand, a
“squishy” item like a stuffed animal might have a cube factor 1.25 meaning that a carton designed to hold four
stuffed animals could in fact hold five.
Item Cartonization Profile Codes are only required for system-driven cartonization in RFPK.
FIELD DESCRIPTIONS
Include Case Pick When this field is not checked, cartonization will only be activated for EACH
Method picks. When this field is checked, cartonization will be activated for both CASE
and EACH picks.
ICNP screen showing factors for standard weight and cube as well as factors for deviations from the
standard weight and cube
After setting up your item cartonization profile codes in ICNP, you attach them to the appropriate items in
ITEM.
Consignees (CONS)
You can deactivate system-directed cartonization for individual consignees by setting the Skip Cartonization
Flag in CONS to Y for Yes.
You perform manual cartonization in the program RFSC (RF Sort Carton). With manual cartonization, you sort
the product on an outbound order and manually assign a carton ID to the inventory in the carton. The carton
ID’s that you manually assign are not validated by AccellosOne 3PL.
A carton is restricted to product from a single order only.
FIELD DESCRIPTIONS
RFPIC The order must be case picked and assigned an outbound pallet ID in RFPIC/
RFPK.
LABELS You need a carton label set up in DOCU and this label must be attached to the
appropriate customers and consignees in CCDU (Customer / Consignee Doc-
ument Setup).
PARCEL PROCESSING Closing a carton in RFSC can trigger a special parcel processing process.
CARTON SIZES Carton sizes must be set up in CTSZ (Carton Size Setup). However, there is
no validation of your carton sizes in CTSZ to ensure that the total weight or
cube has been exceeded.
FUNCTION KEYS
Results Mode
1 Enter RFSC.
RFSC screen
3 Press Enter to accept the default carton size or key in a new carton size and press Enter.
4 Enter or scan in your carton ID.
7 Key in the quantity of product that you wish to place in the carton and press Enter.
8 If the quantity that you entered completes the order, the “Order completed” message will appear. Press
Enter to acknowledge it.
10 When you finish manual cartonization in RFSC, press F4 (RT) and F4 (EX) to exit.
1 When you enter or scan in the carton ID of a closed carton, the following message will appear:
a) Key in 1 and press Enter. a) Key in 2 and press Enter. a) Key in 3 and press Enter.
b) Proceed to add new product to b) Enter or scan in a new carton b) Enter or scan in a new carton
the carton or removing exist- ID or press F4 twice to exit ID and continue processing in
ing product from the carton. RFSC. RFSC.
You perform system-driven cartonization in the program RFPK (RF Wave Pick). With system-driven cartoni-
zation, you scan in your carton ID’s first and then pick the product to be placed in these newly scanned
cartons.
During allocation in Wave Manager, AccellosOne 3PL performs the following tasks:
calculates the number and size of cartons required for each order in the wave based on the item dimen-
sions and your carton sizes in CTSZ
generates a unique UCC-128 number or carton ID for each carton
In RFPK, you scan in your carton ID and slot number for each carton and then scan in the level 1/2 values of
the product that you are packing in the carton.
R EQU IR E M E N T S
QUANTITY BREAK- Only items with a quantity breakdown of pallet/case/each can be cartonized.
DOWN
LABELS You need a carton label set up in DOCU and this label must be attached to the
appropriate customers/carriers/consignees in CCDU (Customer / Consignee
Document Setup).
WAVE MANAGER Only orders that have been waved in the Wave Manager can be cartonized in
RFPK.
CARTON SIZES Carton sizes must be set up in CTSZ (Carton Size Setup).
ITEM Accurate item dimensions (that is, the weights and cube) are required.
CARTON ID’S A UCC-128 label is generated for each carton based on the value in the EAN
UCC Prefix field in CUST. You can customize the serial number portion of the
UCC-128 label by setting up a number series in NUSE (Number Series).
FUNCTION KEYS
Results Mode
1 Enter RFPK.
2 Key in your wave number and press Enter.
3 If prompted to do so, key in your material equipment type code and press Enter.
8 Repeat the above steps for each additional carton ID/slot that you wish to add to your trolley.
9 When you have added all your carton ID’s/slots and are ready to pick, use your arrow keys to position
your cursor over the carton ID that you wish to pack and F3 (SP) to start picking.
14 If the quantity that you enter is less than the pick quantity, the following screen will appear:
15 Key in 1 and press Enter to accept the short pick or key in 3 and press Enter to re-enter the full quantity.
16 Do one of the following:
a) Key in 1 and press Enter. a) Key in 2 and press Enter. a) Key in 3 and press Enter.
b) Go to step 4. b) Key in your new wave number
and press Enter.
Second-level cartonization applies to product that cannot be cartonized by the cartonization engine because
it is oversized, has no ICNP profile attached to it or has missing dimensions in ITEM.
You pick the order normally in RFPK and then manually pack it using a special pick sheet. The pick sheet will
assign system-generated carton ID’s to the product on the order based on the maximum weight and cube
values that you define in CCCC (Outbound Process Configuration) for second-level cartonization.
You perform manual packing in the program EPSD (Enter Packing Details). In this program, you can create
your own carton ID’s or you can use system-generated carton ID’s based on the order number.
R EQU IR E M E N T S
RFPIC The order must be case picked and assigned an outbound pallet ID in RFPIC/
RFPK.
LABELS You need a carton label set up in DOCU and this label must be attached to the
appropriate customers/carriers/consignees in CCDU (Customer / Consignee
Document Setup).
PARCEL PROCESSING Closing a carton in EPSD will trigger a special parcel processing process.
CARTON SIZES Carton sizes must be set up in CTSZ (Carton Size Setup).
AUTO-CONFIRMATION EPSD can be configured to automatically confirm order lines upon successful
completion of packing. Contact Accellos for assistance.
FULL CASE QUANTI- Instead of scanning a case label for each full case, you can simply scan the
TIES item and enter the total number of cases. Weights and dimensions are auto-
matically pulled from the item master and AccellosOne 3PL prints the required
number of shipping labels.
OTHER Many options in EPSD are not configurable by end-users. Contact Accellos for
further information on these options.
1 Enter EPSD.
EPSD screen
2 Key in your packing station code and press Enter or select it from the pick list.
3 Do one of the following:
If you are packing product from a If you are repacking product from
full pallet picked in Normal a pallet with an OPID (outbound
mode: pallet ID):
a) Key in your order number and a) Key in your OPID and press
press Enter. Enter.
4 Key in your carton ID and press Enter or click on Carton ID based on Order for a system-gener-
ated carton ID.
5 Scan in your item code.
6 If required, scan in your level 2 value.
9 If you wish to look up order carton details, click on Order Carton Details . When you finish looking
If the Confirmed flag is selected, it means that the order line has been confirmed.
10 If you wish to look up your carton details, click on Carton Details . When you finish looking up your
11 When you are ready to close your carton, click on Close Carton .
12 Key in your carton size code and press Enter or select it from the pick list.
FIELD DESCRIPTIONS
Units to Repack Only available if you are repacking a pallet with an OPID
Cartons Packed The total number of cartons on the current order that have been packed.
Units Packed The total number of units on the current order that have been packed.
Units to Pick The remaining number of units on the current order to be picked.
Cartons to Pick The remaining number of cartons on the current order to be picked.
1 Enter EPSD.
2 Key in your packing station code and press Enter.
3 Key in your order number or OPID number and press Enter.
4 Key in the carton ID of the carton that you wish to delete and press Enter.
5 Click on Delete .
6 Click on Yes when prompted to confirm your deletion.
You can look up cartons in LOCN to find out which orders shipped in which cartons. The Header Block shows
the carton ID, order number, the carrier tracking number (if any), the carton size code, UCC number and
status.
The Detail Block shows the customer code, item code, order number, line number and current flow. If the
checkbox after the Flow field is selected, the order line has been fully picked.
If you perform an extended query, you can search for carton information by customer code and item code.
1 Enter LOCN.
LOCN screen
2 Press Enter until your cursor is positioned in the field that you wish to query. Then key in your search cri-
teria and click on Execute Query.
3 If you wish to query by customer code or item code, click on Extended Query.
5 When you finish looking up your carton information, click on Exit to exit.
If you are a desktop user, you can delete a closed carton in the program DCAR. When you delete a closed
carton, you can choose to reduce the order line quantity accordingly (the carton did not ship) or you can leave
the order line quantity unchanged (the original carton was damaged and had to be replaced).
1 Enter DCAR.
2 Key in your order number and press Enter.
3 If required, click on the Reduce Order Line Quantity checkbox to deselect it.
4 In the Detail Block, click on Delete Carton for each carton that you wish to delete. Alternatively, you can
Overview
The equipment tracking system allows you to track the equipment used by each RF operator, restrict certain
activity types such as picking, packing, etc. to certain types of equipment and restrict certain RF operators to
certain activity types and equipment types.
When equipment tracking is enabled, the following screen will appear each time an RF operator logs on:
The RF operator must enter a valid material handling equipment code in order to proceed. If the RF operator
enters a material handling equipment type code already in use, one of the following message will appear:
Prompt to remove lock or change MHE Prompt to take over the MHE or reenter MHE
code
The REMOVE THE LOCK message means that there are no active sessions attached to the MHE code and
thus the MHE code is empty. It is safe to remove the lock.
The TAKE OVER THE MHE message means that the Oracle session is still active even though the Unix
session has been dropped (for example, the RF operator switches off the device or removes the batteries). If
you take over another user’s session, that person will lose all his or her work and the gun will be frozen. This
option must be used with extreme caution.
In this program, you activate equipment tracking by selecting Yes in the Enable Equipment Tracking in RF
flag.
RF Checklist (MCHK)
In this program, you set up your checklists for RF equipment types. In the checklist, you define one or more
questions for the RF operator as well as possible answers to these questions. One of the answers is marked
as failed.
In the Header Block, you create a code and description for your new checklist. In the Question Block, you
create a list of questions in the desired sequence. If the Information Only flag is turned on, an answer is not
required for that question. In the Answer Block, you define possible answers.
The checklist code that you create in MCHK is attached to the Checklist tab in MHET for the appropriate
equipment type. It can also be attached to loads in SELO. When an RF operator enters any equipment code
belonging to that equipment type in any RF program, the following prompt appears:
If the RF operator enters 1 for Pass, he or she can proceed to pick the order, put-away the receipt, etc. If the
RF operator enters 2 for Fail, he or she cannot proceed with that equipment code.
MCHK screen
FIELD DESCRIPTIONS
FIELD DESCRIPTIONS
Description Mandatory
A unique sequence number for your question. Your checklist can contain as
many questions as you require.
Question Mandatory
The question or instruction that will display to the RF operator in every RF pro-
gram.
Information Only If you select this flag, the question or statement in the previous field does not
require an answer.
A unique sequence number for your answer. You can have as many answers
as you like for a given question.
Fail Flag If you select this flag, the answer is a fail and the RF operator
will not be able to proceed if he or she selects that answer. At
least one answer for each question should be set up as a fail.
1 Enter MCHK.
2 Click on New .
3 Key in your checklist code and press Enter.
4 Key in a description for your checklist code and press Enter.
5 Click on the Checklist Sequence Number field, key in 1 as your sequence number and press Enter.
6 Key in your first question.
7 Click in the Answer Sequence Number field, key in 1 as your sequence number and press Enter.
8 Key in your answer.
10 Click on Save .
11 Click in the Answer Sequence Number field, key in 2 as your sequence number and press Enter.
12 Key in your answer.
13 If required, click on the Fail Flag if the answer is a fail.
14 Click on Save .
15 Repeat the above three steps for each additional answer to your first question.
16 if you wish to add a second question to your checklist, click in Checklist Sequence Number field, key in 2
as your sequence number and press Enter.
17 Repeat steps 7 to 10 for the first answer to your second checklist question.
18 Add your additional answers to the second checklist question.
In this program, you attach the checklist code that you created in MCHK to the Checklist tab in MHET for the
appropriate equipment type. If you perform RF interleaving in RFITLV, you must specify the equipment type’s
vertical height factor and excluded warehouse activity types (if any).
MHET screen
FIELD DESCRIPTIONS
Description Mandatory
Labor Standard Modifier See the “Operational Board” section in the Operations 2 Guide.
Location Required N = No
Y = Yes
If you select N for No, a staging location is not required in MHEC for material
handling equipment codes assigned this equipment type. If you select Y for
Yes, a staging location is required in MHEC for material handling equipment
codes assigned this equipment type.
Staging locations are not mandatory for material handling equipment codes.
However, they allow you to track product more effectively on an open order.
For example, if you assign staging location S100 to a given forklift and then
pick 10 cases of product using this forklift, AccellosOne 3PL will create a
record in the Location Block of LOEN showing 10 cases of product in location
S100.
The height or vertical reach of this equipment type, The vertical height factor
code in this field must match the vertical height factor code of the location
before an RF operator assigned this equipment type can be assigned an inter-
leaving task for the location.
FIELD DESCRIPTIONS
If you enter one or more activity types in this field, the RF operator will not be
able to use this equipment type for this activity type in RFITLV.
Checklist In this field, you enter the checklist code that you created in MCHK.
MHET screen showing electric lift equipment type that can be assigned to locations whose vertical
height factor = 1 to 5
In this program, you set up your material handling equipment codes. RF operators must enter one of these
equipment codes each time that they enter an RF program.
MHEC screen
FIELD DESCRIPTIONS
Description Mandatory
The material handling type for this material handling equipment code.
Warehouse Code Only available if Location Required flag set to Yes in MHET for the material
handling type
FIELD DESCRIPTIONS
Location Code Only available if Location Required flag set to Yes in MHET for the material
handling type
The staging location code for this material handling equipment code. In LOCA,
the following setup is required for this location:
its location type in LOTP must be staging
RF Operator (RFOP)
In this program, you set up your activity type and material handling type exclusions for RF operators. If you
specify one or more task profiles for the RF operator on the Task Profiles tab, the RF operator will be
restricted to those task profiles.
NOTE Activity type and material handling type exclusions are only supported in
RFITLV.
Locations (LOCA)
In this program, you define your location height restrictions for each location. Only equipment types whose
vertical height factor code matches the location’s vertical height factor code can be assigned a task in this
location.
In this program, you set up your warehouse shifts. Warehouse shifts are optional in equipment tracking. If you
set up warehouse shifts, the RF checklist will need to be performed by the RF operator only once per shift. If
you do not set up warehouse shifts, the RF checklist will need to be performed each time that an RF operator
logs on (that is, more than once per shift if the RF operator logs off during a shift).
FIELD DESCRIPTIONS
Description Mandatory
Equipment tracking data is stored in the Oracle database. If you wish to look this data up, you must write a
d’Amigo query.
Overview
Task interleaving is a fully automated solution to task assignment. Instead of RF operators entering individual
RF programs to perform put-way, picking, directed moves and replenishments at their own pace and in a
sequence that does not take into account the tasks of other RF operators, AccellosOne 3PL consolidates all
tasks in a single centralized “bucket”.
When an RF operator logs into RF, he or she is assigned the next available task in the bucket be it put-away,
picking, a directed move or a replenishment. The next available task is based on a number of factors
including:
the RF operator’s equipment
the RF operator’s proximity to the task’s location
the RF operator’s task profile
the location’s height restrictions
the priority assigned to the task’s activity type
the task’s pick method (full pallet pick vs. case pick)
the level of congestion in a particular aisle
If an RF operator chooses to skip a task, AccellosOne 3PL will record the skipped task as well as the operator
who skipped it.
This purpose of task interleaving is to optimize the distribution of warehouse tasks such that travel times in
the warehouse are reduced to a minimum, urgent tasks are performed first and congestion in warehouse
aisles is avoided whenever possible.
The RF operator performs task interleaving in RFITLV (RF Interleaving). RFITLV supports all the standard
functions performed in RFCH, RFPU, RFPIC/RFPV, RFRP and RFCE. RFITLV does NOT support manual
relocations in RFRL, merging OPID’s in RFMG, merging inventory in RFMI, moving product in RFST or
loading product in OLOP.
In this program, you activate task interleaving by setting the Enable Task Interleaving flag to the appropriate
value: Create All Tasks or Create Tasks According to Zone Setting.
If you select “Create All Tasks”, task interleaving will be activated for all warehouse zones whose zone type is
set to I for Interleaving in WHZO. If you select “Create Tasks According to Zone Setting”, task interleaving will
be activated only for warehouse zones whose zone type has been set to I for Interleaving and whose Task
Required flag has been set to Yes.
COMP screen showing Enable Task Interleaving set to Create All Tasks
WATP screen
A C T I V I T Y D E S CR I P T I O N A CT I V I T Y D E S CR I P T I O N
1 Clock-in 26 Picking
2 Clock-out 27 Unloading
25 Packing
Only locations attached to a warehouse zone whose zone type code has been set to I for Interleaving can be
used for interleaving. See “Warehouse Zones (WHZO)” on page 84 for further information on WHZO.
If you selected the Create Tasks According to Zone Setting option in COMP, you must set the Task Required
flag to Yes for each warehouse zone in WHZO that you wish to activate.
WHZO screen showing interleaving type zone code and Task Required flag
You must define your aisles in the Location Attributes Block of WARE. See the Setup Guide for further infor-
mation on WARE.
Locations (LOCA)
In this program, you define your location height restrictions for each location. Only equipment types whose
vertical height factor code matches the location’s vertical height factor code can be assigned a task in this
location.
In this program, you define the maximum number of RF operators allowed in a warehouse aisle at any one
time.
FIELD DESCRIPTIONS
Max. Number of Opera- In this field, you define “congestion” in a warehouse aisle for interleaving pur-
tors poses; that is, if the number of operators in a task profile exceeds this number,
the extra operators will not be assigned any tasks until one or more existing
operators completes his or her task(s).
RF Interleaving in RFITLV
You perform task interleaving in RFITLV (RF Interleaving). Depending on the next available task, RFITLV calls
one of the following programs: RFCH, RFPU, RFPIC/RFPV, RFRP and RFCE. Refer to the documentation on
these programs for further information.
R EQU IR E M E N T S
COMP The following fields must be configured: RFITLV First Check Same Location
for Task, RFITLV Second Check Same Aisle for Task and RFITLV Third Check
Same Zone for Task.
R EQU IR E M E N T S
PALLET BUILDING If you wish to take advantage of the Pallet Build engine, setup is required in
IPBR, ITEM, REGI and CONS.
OPERATOR RESTRIC- You can deactivate task interleaving for some or all RF operators by setting up
TIONS activity type exclusions in RFOP. For example, RF operator 1 can only pick,
RF operator 2 can only put-away and RF operator 3 can only relocate.
1 Enter RFITLV.
2 If prompted to do so, key in your task profile code and press Enter. Otherwise, press Enter to acknowl-
edge your pre-assigned task profile code.
4 Repeat the above steps for each additional task assigned to your task profile.
5 When you finish performing all your tasks, press F4 (RT) to exit. Then key in N for exit and press Enter.
INDEX
A E
accessing RF 118 entry of expiry dates in RFCH 150
adjusting non-serial number inventory 301 EOSU (Exclude Orders from RF Substitution) 245
adjusting serial number inventory 310 EPSD (Enter Packing Details) 388
alternate item codes in RFCH 170 equipment tracking 400
alternate item codes in RFPU 187 excluding orders from overpicking in EOSU 218
assignments, pick method 196 extra charge setup 81
auto-confirming receipts in RFCH 143 extra charges, adding to receipt/order in RFEC 325
auto-confirming receipts in RFPU 143, 179
F
B first level cartonization 364
BAPR (Bar Code Profile Code) 11
blind receiving in RFCH 140 H
holds, placing product on in RFCH 172
C holds, placing product on in RFPIC 214
cartonization 364
Cartonization tab (MRFP) 364 I
cartons, deleting in DCAR 397 ICIN (Inventory Count Investigation) 223
cartons, looking up in LOCN 395 ICNP (Item Cartonization Profile Code) 373
CASE (Case Picking) 236 ICOC (Item Consignee Configuration) 106
case picking 206 IHZV (Item Hazardous Material Violation) 97
catch weight tolerances 259 inbound flows, understanding 139
CCCC (Outbound Process Configuration) 107, 368 interleaving See task interleaving
CCDU (Customer / Consignee Document Setup) 96 inventory counting in RFPIC 221
CCOR (Customer Consignee Outbound Rules) 111 inventory, merging 318
changing your company 118 IPBR (Item Pallet Build Restrictions) 98
CONS (Consignees) 374 Item Consignee Configuration (ICOC) 106
Consolidation Method for Allocated Lines field (CUST) 94 Item Hazardous Material Violation (IHZV) 97
count backs, performing in RFPIC 221
CRM tasks, performing in RF 334 L
CTPA (Clear Terminal Pick Assignments) 360
LOCN (Look Up Carton) 227, 395
CTSZ (Carton Size Setup) 366 LOENRF (RF Look Up Entity Information) 130
CUST (Customer Codes) 94
LOLORF (Look Up Location - RF) 128
Customer/Consignee Outbound Rules (CCOR) 111
looking up temperature and trailer information in LORE 175
look-up programs 117
D LOORRF (Look Up Orders - RF) 133
DCAR (Delete Carton) 397 LORERF (RF Look Up Receipts) 131