 A330-200/300 

 TECHNICAL TRAINING MANUAL 


 CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6) 
 OXYGEN 
This document must be used for training purposes only

Under no circumstances should this document be used as a reference

It will not be updated.

All rights reserved


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of AIRBUS S.A.S.

  AIRBUS Environmental Recommendation


Please consider your environmental responsability before printing this document.
A330-200/300 TECHNICAL TRAINING MANUAL

OXYGEN
PASSENGER OXYGEN
Passenger Gaseous Oxygen System D/O (3) . . . . . . . . . . . . . . . . . . . . 2
G7108471 - G3RT1TU

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  TABLE OF CONTENTS Nov 21, 2008
35 - OXYGEN Page 1
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


GENERAL
The cabin fixed oxygen system supplies (automatically or manually
controlled) oxygen to the occupants, in case of cabin depressurization.
The system stores its oxygen in interconnected cylinders (5 up to 18),
behind the right hand sidewall lining in the forward cargo compartment.
The oxygen goes to the mask containers in the cabin, via two main supply
lines and a network of pipes.
The containers are above the passenger seats, in the lavatories, in each
galley, at each cabin crew station and if installed (option) in Flight Crew
Rest Compartment (FCRC) and Bulk Crew Rest Compartment (BCRC).
Each container has 2, 3, 4 or 5 masks.
Two oxygen regulators control the flow rate.
The Quantity Calculation and Control Unit (QCCU) supplies the value
of the average temperature compensated pressure indicated on the ECAM
system page, and a not temperature compensated to the oxygen servicing
panel.
G7108471 - G3RT1TU - FM35D3000000001

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 2
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

GENERAL

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 3
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


MAIN COMPONENTS DISTRIBUTION
When the passenger oxygen distribution system is operated, the
OXYGEN STORAGE pressure reducer supplies low-pressure oxygen via two
The passenger gaseous emergency oxygen is contained in the electro-pneumatic oxygen regulators to the two main supply lines.
passenger oxygen storage system. One line is installed below the cabin floor along the RH side of the
The emergency oxygen is kept in the oxygen cylinders (nominal aircraft
pressure 1850 psi (127 bars) at 21°C. This makes sure that sufficient oxygen is available for the passengers
The Pressure Reducer outlet is nominally 130 psi. and the cabin crew if one of the supply lines is damaged in case of
The storage system also lets you fill the cylinder assemblies. engine burst. The passenger oxygen distribution system supplies
OVERPRESSURE PROTECTION: emergency oxygen to each oxygen container above the passenger
- Cylinder pressure above 2770 psi (191 bar), a Safety Disk shears seats, in the lavatories, at the cabin attendant stations and optionally
and the related cylinder empties overboard. the crew rest rooms.
- Pressure in the low pressure system above 233 psi (16 bar), an The system is only pressurized in an emergency.
independent Pressure Relief Valve relieves the excess of pressure Flexible hoses connect the emergency oxygen containers to the supply
overboard. system.
In all cases, the green indicator is blown out.
OXYGEN CONTROL AND INDICATING
The passenger oxygen control can be done either:
- automatically when the cabin altitude exceeds 14000 ft (altitude
switch)
- or manually from the MASK MAN ON switch.
G7108471 - G3RT1TU - FM35D3000000001

NOTE: The oxygen container door can be mechanically unlatched


by means of a manual release tool.
Information about the condition of the passenger oxygen system is
given on:
- the ECAM,
- the OXYGEN panel 211VU and the maintenance panel 285VU.
- the MCDU and QCCU front face.

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 4
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

MAIN COMPONENTS - OXYGEN STORAGE ... DISTRIBUTION

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 5
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


OPERATION
BEFORE OPERATION
The pressure reducer reduces the bottle pressure, from 1850 psi to
130 psi.
The two oxygen regulators are closed.
The two main distribution Shut-Off Valves (SOVs) are open.
The bleed ventilation valve is open, to avoid a risk of pressure build
up, or to cause the unlatching of the door.
G7108471 - G3RT1TU - FM35D3000000001

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 6
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

OPERATION - BEFORE OPERATION

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 7
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


doors and makes oxygen available to the mask when de pressure is
OPERATION (continued) 21 psi (1.5 bar) and 43 psi (3.0 bar).
-Distribution mode: A continuous flow of oxygen is supplied to the
DURING OPERATION
masks at a suitable pressure based on the cabin altitude, between 6.4
When the cabin pressure decreases to a pressure equivalent to 14.000 psi (0.44 bar) at 10 000ft and 98.4 psi (6.8 bar) at 40 000ft.
ft (4267 m) (+250/-750ft) the altitude pressure switch will close. This The shut-off valve operates electrically.
action operates the emergency oxygen system. If the altitude pressure It has two electrical inputs, one to open the valve, one to close it (at
switch does not operate, you can operate the MANual ON P/BSW on reset).
the OXYGEN panel, located on the overhead panel. Each shut-off valve also has two electrical switches:
The oxygen regulators are energized, delivering a flow as a function - The ''valve fully open'' switch, which operates the ''SYS ON'' light.
of the cabin altitude. - The ''valve not fully closed'' switch, which possibly triggers a warning
The PASSENGER SYS ON light comes on, and the tape in case of disagreement between the valve position and the selection.
announcement is started. A test port is given for ground level simulation of high altitudes using
The air caught in the distribution lines is bled through the open a vacuum source. By using this method, the oxygen pressure schedule
bleed/ventilation valve during 5 seconds, and then this valve closes. can be verified without removing the unit from the aircraft.
The oxygen pressure builds up.
The pneumatically controlled door latches let the oxygen container
doors open and the masks fall down.
The passenger pulls the mask to his face, which releases the oxygen
flow release pin.
Oxygen is supplied to the mask.
An oxygen flow indication, which is the green part of the mask
reservoir bag, inflates.
G7108471 - G3RT1TU - FM35D3000000001

The Oxygen regulators are designed to supply a continuous flow of


oxygen up to 556 masks (depending the version of aircraft).
The oxygen regulator is made of two parts:
- A pressure-regulation unit
- A shut-off valve
The pressure-regulation unit operates pneumatically in two operation
modes.
-Surge mode: The surge pressure of 50 psi (3.4 bar) to 124 psi (8.6
bar) releases the oxygen/air mixture through the bleed/vent valve.
After this there is no more air in the oxygen-distribution lines, but
only oxygen. This surge of pressure also unlatches the mask container
CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 8
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

OPERATION - DURING OPERATION

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 9
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


RESET
RESET OPERATION
To set the system back to the initial configuration, the RESET P/BSW
on the maintenance panel is pushed:
- the electrical circuit is set to the initial condition,
- the oxygen regulators close,
- the main distribution SOVs open, if they are closed.
The RESET P/BSW operates only if the cabin pressure is below 10.000
ft.

NOTE: Note: the Bleed/Vent Valve opens mechanically.


RESET INDICATING
The RESET ON light goes off when the reset is completed (3 seconds).
The PASSENGER SYS ON light goes off.
RESET FAILURE
The ON light in the RESET P/BSW, on the maintenance panel 285VU
will not go off and the FAULT light comes on if:
- the electrical circuit for the gaseous system does not return to the
initial condition.
The warning REGUL LO PR will be shown on the ECAM if:
G7108471 - G3RT1TU - FM35D3000000001

- the gaseous system does not return to the normal condition after you
push the RESET P/BSW,
- one of the oxygen regulators is not fully closed,
- one of the main distribution SOVs is not fully open,
- both main distribution SOVs close when the system has been
operated.

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 10
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

RESET - RESET OPERATION ... RESET FAILURE

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 11
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


ENGINE BURST
If an engine turbine bursts and damages a main oxygen supply line:
- the differential pressure SW sends a signal to the appropriate main
distribution SOV,
- the appropriate main distribution SOV closes,
- the non-return valve will stop the oxygen supply to the related main
supply line,
The riser line SOVs will stop the oxygen supply to a damaged riser or
fall line.
DIFFERENTIAL PRESSURE SWITCH
The differential pressure SW compares the pressure in the two main
distribution lines in the engine burst area. If the pressure difference
between the lines is more than 3 psi (0.2 bar), the SW energizes the
applicable main distribution SOV, which closes.
RISER LINE SOVs
The riser lines SOVs are installed in the engine burst area:
- on the riser lines at FR 37.2, 40.1, 46, 53.1 and 53.9,
- on the fall lines at FR 38, 41, 49 and 53.4.
They are installed immediately after the connection with the main
supply line.
G7108471 - G3RT1TU - FM35D3000000001

The riser line SOVs are pneumatically controlled so that oxygen is


not supplied to a damaged riser line.
In normal operation, the riser line SOVs are open. They close if the
flow increases more than 0.42 kg. min (0.9259 lb. min).
A valve will stay closed until the pressure difference across the valve
is less than 14.5037 psi (1 bar).

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 12
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

ENGINE BURST - DIFFERENTIAL PRESSURE SWITCH & RISER LINE SOVS

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 13
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


DOOR/OXY ECAM PAGE
The next slide introduces indicating concerning the passenger oxygen
system on the DOOR/OXY ECAM page.
G7108471 - G3RT1TU - FM35D3000000001

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 14
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

DOOR/OXY ECAM PAGE

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 15
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


CMC MESSAGES AND BITE
FAILURE MESSAGE TO THE CMC
The applicable message is sent to the CMC if:
- the QCCU fails,
- a pressure transducer fails,
- the temperature transducer fails,
- one or more oxygen regulator or the main distribution SOVs is not
in the correct position,
- both main distribution SOVs are closed,
- the pressure after the pressure reducers is too low,
- the low pressure SW fails.
TEST/BITE
The QCCU has power up test and a continuous test. It checks:
- the pressure transmitters,
- the temperature transducer,
- the QCCU.
G7108471 - G3RT1TU - FM35D3000000001

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 16
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

CMC MESSAGES AND BITE - FAILURE MESSAGE TO THE CMC & TEST/BITE

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 17
A330-200/300 TECHNICAL TRAINING MANUAL

PASSENGER GASEOUS OXYGEN SYSTEM D/O (3)


QCCU TEST
There is a warning light on the QCCU for each of the faults. The related
light (PRESSURE, COMPUTER or TEMPERATURE) comes on when
a fault occurs.
If the fault is corrected, the light stays on until the QCCU is reset or the
power is switched off.
The QCCU has a TEST P/B to test the lights on the unit.

NOTE: Before you do a test, you must pull out the door stops and turn
them to 90 degrees.
This makes sure that the oxygen masks do not fall out.
To make sure that a door latch assembly releases the door, you can do a
ground test with the manual release tool.
To make sure that the pneumatic latches operate correctly; you can do a
functional test with the MANual ON P/BSW.
After a functional test, you must also release the pressure from the system
through the bleed/vent valve.
After a test, you must close the doors, turn the doors stops to 90 degrees
and release them.
After a functional test, you must push the RESET P/BSW to set the system
back to initial.
G7108471 - G3RT1TU - FM35D3000000001

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 18
A330-200/300 TECHNICAL TRAINING MANUAL
G7108471 - G3RT1TU - FM35D3000000001

QCCU TEST

CMQ - SA family to A330-200/300 - T1 (Lvl 2&3) (GE CF6)  PASSENGER GASEOUS OXYGEN SYSTEM D/O (3) Nov 20, 2008
35 - OXYGEN Page 19
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE G7108471
NOVEMBER 2008
PRINTED IN FRANCE
AIRBUS S.A.S. 2008
ALL RIGHTS RESERVED

AN EADS COMPANY