Experion Vista is a powerful and versatile software platform that incorporates innovative applications for supervisory control
and data acquisition (SCADA). Built upon the proven technologies of the Experion platform, Experion Vista features are
targeted for smaller unit process operations involving Honeywell’s HC900 Hybrid Controller.
• Open connectivity – The Experion Vista platform deployed in a number of ways: as the operator’s view to the
incorporates, as standard, open technologies to simplify process, as an engineering configuration station, as a casual
integration with business and information systems. user interface or as a way of performing diagnostics.
These technologies include the ODBC driver, Visual
Basic scripting, the OPC Client interface, the OPC Data When configuring Flex Stations you can choose between two
Display Client and the OPC DA server for read/write
different connection methods:
access to the database.
• Advanced system infrastructure –The Experion Vista Static – Provides a permanent, dedicated link to the server. This
platform includes, as standard, a complete infrastructure is the recommended connection type for full-time operations.
with an advanced alarm/event management subsystem,
built-in system displays, configurable reports, extensive Rotary – Provides an as required connection to the server. This
history collection and standard system trends.
is the recommended connection type for staff who do not need
full-time access. Rotary connections are advantageous from a
• SCADA interfaces – An array of standard drivers are
provided with the Experion Vista platform. The primary licensing point of view because the license only specifies the
focus for data acquisition and the supervisory control number of simultaneously connected Flex Stations (concurrent-
interface is the HC900 hybrid controller (both standard use licensing). Rotary Flex Stations also provide the option of
and redundant) via the Honeywell Universal Modbus or using the Experion Station interface or Microsoft’s Internet
OPC Client drivers. Other Honeywell products Explorer. The Internet Explorer interface is ideal for staff that
supported in combination include the S9000/LCS620 prefers to use familiar desktop tools to view the process and the
controllers, DPR, DR and X-Series recorders. Legacy same licensing and security mechanisms as used in Station
products include the UMC800 and UDC controllers. apply.
Allen-Bradley PLC, Modbus RTU interface (serial or
Ethernet) and OPC DA client complete the standard set
of drivers.
• Line graphs
• Bar graphs
• Hairline readout A standard group display enables intuitive control of multiple loops and
view of associated points via SCADA faceplates
• Configurable trend density
Each group contains up to eight points using standard faceplates The OPC Display Data Client allows the display designer to
for analog and digital status points. Group faceplates are insert OPC data into a display without the need to purchase and
consistent in design, functionality and appearance with the build points. This is ideal for data that only needs to be visualized
standard detail displays. Each group has three standard views by the operator and does not need to be alarmed or historized.
available including faceplate, group trend (with control OPC data acquired in this way supports both reads and writes.
parameters accessible) and numeric trend.
Experion Vista continues to support dsp-type displays (file
extension of .dsp) you may have created in previous releases.
The original Display Builder tool continues to be supplied with
Experion Vista.
Custom Displays
HMIWeb custom display with embedded trend object and interactive
The Experion HMIWeb technology provides the latest in faceplate popup
With this technology, which is based on Web standards using Integrated Alarm and Event Management
HTML as the native display format, you can provide process
graphics within a secure Station environment or from Microsoft’s The innovative alarm management solutions in Experion Vista
Internet Explorer. Salient features of the latest release of improve the operator’s ability to minimize process interruptions.
HMIWeb Display Builder include:
Alarm and event analysis feature improvements are based on
• Shape library for plant equipment static objects and research relative to technologies for improving the handling of
the use of shape sequences, dynamic shapes and process upset conditions. The standard Alarm Summary display
popups including standard SCADA faceplates enables operators to focus more clearly on the problem at hand.
• Advanced custom trend object enabling visualization
of real-time and historical process information
The Experion Vista Platform makes extensive use of the SQL commands from ODBC client applications such as Microsoft
VBScript scripting language throughout the supervisory system. Access. The server database is exposed as a number of read-
Users can create a script that will run when a display is active or only ODBC tables that include points, event history and process
scripts can also be attached to server objects like point history. Driver features include:
parameters, alarm events, report completion and other events. • Open read-only access to real-time and historical data
• Throttling to prevent performance impact
• Fully functional examples for productivity improvements
Display Scripting
Users can extend the functionality of graphic displays by writing Network Server
event-based scripts for display objects. Scripts are typically used The network server provides efficient access to the Experion
to create animation that is not possible with standard Vista platform database for network-based applications such as
functionality. Microsoft Excel Data Exchange.
Experion Vista Overview, PN-07-22-ENG 8
Configuration Studio
OPC Server
The standard Universal Modbus driver supports HC900 along You can expand Experion Vista systems to include more points
with most Honeywell measurement, control and recorder (up to a maximum of 2,050), more Flex Stations (up to a
products. Acronyms such as LOOP 1 PV and TAG 23 are used maximum of five), or to include the Alarm Pager or Point Control
for reference instead of Modbus addresses when developing Scheduler option without taking the system offline.
database point assignments. Both single and redundant networks
are supported for HC900. The standard OPC client driver can Upgrades to Experion Vista
also be used to interface with Honeywell’s HWIOPC server for
HC900, supporting single or redundant networks. ®
Upgrading from older PlantScape Vista and SCADA releases to
Experion Vista is easy and efficient. Previous PlantScape Vista
To reduce development time, an HC900 Point Build Utility is R400 Quick Builder database files and custom displays will fully
freely available to the user to import the HC Designer tag export migrate to Experion Vista.
database files and selectively develop HC900 points for Experion
Vista. You can use the wizard to develop analog and digital Runtime Only Solutions
status points for control loops, SP programmers, signal tags and
variables. Hardware and point files, which are developed by the A runtime only license is available for 350-point or 2,050-point
tool in minutes, can be imported into Quick Builder for database systems only. This license type is used for applications where
development, thus greatly improving productivity. access to development tools for changing the database is not
required. Users can access Station for groups, trends, recipes,
User Documentation profiles and security, as well as normal supervisory functions
(depending on the local Station security that is applied). A
Comprehensive Experion Vista documentation is available via separate Experion Vista development/run-time license is needed
help menus and via Knowledge Builder, the electronic Experion to provide access to development tools such as Quick Builder.
Experion Vista Overview, PN-07-22-ENG 10
Item Specification
Server and Client hardware requirements Dual Core Intel 1.86GHz, 2GB RAM computer (for detailed hardware
specifications refer to the Experion Vista Specification FS03-200-301)
Related solutions for the HC900 Hybrid • HC Designer configuration software – Windows-based configuration
Controller software for the HC900.
• 559 and 1042 Operator Interface LCD display – supporting operator
access to the HC900 directly.
• HWIOPC Server – OPC server for HC900 supporting all controller types,
single and redundant networks.
• HC900 Pointbuild Utility for generating a Quick Builder database using
HC Designer tag export files.
o Ver. 1.2 - supports fixed Modbus map for Universal Modbus
driver only, uses named addresses (acronyms))
o Ver. 2.2 - supports fixed and custom Modbus map for Universal
Modbus driver (uses Modbus hex addresses) and OPC Client
drivers (for HWIOPC server, fixed Modbus map)
Experion Vista Overview, PN-07-22-ENG 11
More Information
For more information on Experion Vista, visit
www.honeywell.com/ps/field or contact your
Honeywell account manager.