Sie sind auf Seite 1von 37

SISTEM
TATA
UDARA


UTILITAS
2
|
D3
ARSITEKTUR
BANGUNAN
GEDUNG
UNIVERSITAS
LAMPUNG

MUTU
UDARA
DALAM
BANGUNAN


KENYAMANAN


VENTILASI
 KESEHATAN


ORIENTASI
MATAHARI

KENIKMATAN

PENGHUNI
DAN

PENGGUNA

BANGUNAN

VENTILASI

MENJAIM
KETERSEDIAAN
UDARA
LUAR
YANG

MASUK
KE
DALAM

BANGUNAN


PERTUKARAN
UDARA
BAIK,
PENGHAWAAN
DAN

PENGKONDISIAN
UDARA
DALAM
RUANG
TIDAK
BEGITU

DIPERLUKAN

ORIENTASI
MATAHARI

CAHAYA
YANG
DAPAT
DIMANFAATKAN
DALAM
RUANG,
AGAR

TIDAK
DIPERLUKAN
PENCAHAYAAN
BUATAN


MATAHARI
‐>
RADIASI
PANAS
‐>
SUHU
MENINGKAT

PENURUNAN
MUTU
UDARA


BAHAN
SINTETIK
SEBAGAI
MATERIAL

BANGUNAN

OBAT
PEMBASMI
SERANGGA

TANAMAN
HIAS

ASAP
ROKOK,
DEBU

GAS
BERACUN
DARI
DAPUR
DAN
GARASI

PENGKONDISIAN
UDARA

AC
(AIR
CONDITIONING)
ATAU
SISTEM
TATA
UDARA
YANG

DIPUSATKAN
MENGGUNAKAN
UNIT
PENGHANTAR
UDARA
(
AIR

HANDLING
UNIT)


MEMPERTAHANKAN
SUHU
DAN
KELEMBABAN
DALAM

RUANGAN
DENGAN
CARA
MENYERAP
PANAS
YANG
ADA
DALAM

RUANGAN


MESIN
TATA
UDARA

SISTEM
TATA
UDARA
LANGSUNG

(DIRECT
COOLING)


UDARA
DITURUNKAN
SUHUNYA
OLEH

REFRIGERANT
DAN
DISALURKAN
KE
DALAM

RUANGAN
TANPA
SALURAN
UDARA
(DUCTING)


AC
WINDOW
:
0,5‐2
PK

AC
SPLIT
UNIT
:
0,5
‐3
PK

AC
PACKAGE
UNIT
:
UP
TO
10
PK

AC
WINDOW

KONDENSOR,
KOMPRESOR,
EVAPORATOR
DAN

BLOWER
BERADA
DALAM
1
KOTAK


AIR
HASIL
KONDENSASI
DITAMPUNG
DI
BAGIAN

BAWAH
KOTAK
DAN
DISALURKAN
KE
LUAR

AC
SPLIT
UNIT

TERDIRI
ATAS
2
BAGIAN

OUTDOOR
UNIT


KONDENSOR
DAN

KOMPRESOR


INDOOR
UNIT

EVAPORATOR
DAN

BLOWER/FAN

AC
SPLIT
UNIT
DENGAN
KAPASITAS
BESAR,
INDOOR

UNIT
BISA
LEBIH
DARI
1
JUMLAHNYA
(MULTI
SPLIT)

SEDANG
OUTDOOR
UNIT
TETAP
1


VARIASI
PEMASANGAN
INDOOR
UNIT

WALL
MOUNTED

CEILING
MOUNTED

FLOOR
MOUNTED

MODEL
CASSETTE

PACKAGE
UNIT

KADANG
DIHUBUNGKAN
DENGAN
SALURAN

UDARA
(DUCTING)


KADANG
MEMPUNYAI
2
UNIT
TERPISAH

UNIT
LUAR
:
KONDENSOR,
KOMPRESOR,
FAN

UNIT
DALAM
:
KUMPARAN
PENDINGIN

(EVAPORATOR),
SARINGAN
UDARA,
FILTER,
DAN

PANEL
KONTROL

SISTEM
TATA
UDARA
TIDAK
LANGSUNG

(
INDIRECT
COOLING)

CENTRAL
AIR
CONDITIONING
SYSTEM


SISTEM
INI
MENGGUNAKAN
AIR
ES
(CHILLED
WATER)

DENGAN
SUHU
±
5∘C
SEBAGAI
REFRIGERAN


AIR
ES
DIHASILKAN
DALAM
CHILLER

TERDAPAT
BLOWER
DAN
SARINGAN
UDARA


UDARA
DITIUPKAN
DI
ANTARA
KUMPARAN
YANG
BERISI

AIR
ES
DALAM
AHU

UNIT
PENGHANTAR
UDARA


(AIR
HANDLING
UNIT)

FUNGSI
AHU
:

1.  MENCAMPUR
UDARA
BALIK
DARI
RUANGAN

DENGAN
UDARA
LUAR
PADA
PROSENTASE

TERTENTU

2.  MENDINGINKAN
UDARA
TERSEBUT
SESUAI

SUHU
YANG
DIINGINKAN

3.  MENYARING
UDARA
DARI
PARTIKEL
DEBU

4.  MENGALIRKAN
SEJUMLAH
UDARA
DINGIN

MELALUI
SALURAN
UDARA
(DUCTING)

JENIS
AHU
:

1.  FAN‐COIL

UNIT

2.  SUSPENDED

AHU

3.  FLOOR‐
MOUNTED

AHU

4.  BUILT–UP

AHU

CHILLER

JENIS
CHILLER
:

AIR
COOLED

CHILLER

WATER
COOLED

CHILLER

KONDENSOR

FUNGSI
:
MELEPAS
KALOR
REFRIGERAN
KE
MEDIUM

SEKELILINGNYA
(AIR
ATAU
UDARA)
AGAR
REFRIGERAN

DAPAT
DIKONDENSASIKAN
DAN
DIUAPKAN
KEMBALI
KE

EVAPORATOR


JENIS
KONDENSOR
:

AIR
COOLED
CONDENSER

WATER
COOLED
CONDENSER

EVAPORATIVE
CONDENSER

COOLING
TOWER

SEBAGAI
ALAT
PENUKAR
KALOR
DAN
MASSA
DI
ANTARA

AIR
DENGAN
UDARA,


SEHINGGA
AIR
PENDINGIN
KONDENSOR
DENGAN
SUHU

TINGGI
DAPAT
DITURUNKAN,


DAN
SELANJUTNYA
AIR
DAPAT
DIGUNAKAN
KEMBALI

UNTUK
KEBUTUHAN
PENDINGIN
KONDENSOR


JENIS
COOLING
TOWER

1.  MECHANICAL
DRAFT/FORCE
DRAFT

2.  NATURAL
ATMOSPHERIC
DRAFT/INDUCE
DRAFT

3.  MECHANICAL
&
ATMOSPHERIC

JALUR
DAN

SALURAN

UDARA

DINGIN

(DUCTING)

PEMASANGAN
SALURAN
DISTRIBUSI
TATA

UDARA
PERLU
DIINTEGRASIKAN
DENGAN

SISTEM
DAN
POLA
STRUKTUR
YANG
ADA
:

• PENUTUP
LANTAI
DENGAN
RONGGA
DI

BAWAHNYA
(RAISED
FLOOR)

• PENUTUP
LANTAI
TANPA
RONGGA

• JARINGAN
UTILITAS
LAIN


PENGENDALIAN
PASOKAN
UDARA

1.  PENGENDALIAN
VOLUME
UDARA
TETAP
(CV‐
CONSTANT
VOLUME)

2.  PENGENDALIAN
VOLUME
UDARA
TIDAK

TETAP
(VV‐VARIABLE
VOLUME)

CONSTANT
VOLUME

SISTEM
INI
MENJAGA
VOLUME
PASOKAN
UDARA
PADA

SUHU
YANG
BERUBAH‐UBAH


MENYEDIAKAN
SUATU
PERGERAKAN
UDARA
DAN

PASOKAN
UDARA
SEGAR
YANG
TETAP
PADA
RUANGAN

YANG
MEMBUTUHKAN


SUARA
YANG
TIMBUL
PADA
SALURAN
UDARA
KONSTAN,

MENGURANGI
GANGGUAN
BAGI
PENGGUNA


BUTUH
ENERGI
YANG
BESAR

VARIABLE
VOLUME

VOLUME
PASOKAN
UDARA
AKAN
BERKURANG

DENGAN
TURUNNYA
SUHU
UDARA
DALAM

RUANGAN

MEMBUTUHKAN
ENERGI
RENDAH

ALIRAN
UDARA
TIDAK
TETAP
AKAN

MENYEBABKAN
PERGERAKAN
UDARA
YANG

KURANG
MEMADAI
DAN
MENYEBABKAN

TIMBUL
SUARA
BISING

SISTEM
ZONA
TUNGGAL

1.  DIGUNAKAN
UNTUK
RUANGAN
BESAR

2.  BIAYA
AWAL
RELATIF
MURAH

3.  SEDERHANA

4.  MUDAH
PERANCANGANNYA

5.  MUDAH
PEMASANGANNYA

6.  MUDAH
PERAWATANNYA

7.  MEMBUTUHKAN
SALURAN
UDARA
UTAMA
DENGAN

DIMENSI
YANG
BESAR

8.  SULIT
MENGATUR
SUHU
DAN
KELEMBABAN
UDARA

UNTUK
RUANGAN
YANG
BANYAK,
JIKA
TIDAK

DILENGKAPI
PENGATUR
SUHU
UDARA
TERPISAH

SISTEM
ZONA
GANDA

1.  DIPERLUKAN
PENGENDALIAN
TERPISAH

2.  TERMOSTAT
PADA
TIAP
ZONA
MENGATUR

SEBUAH
DAMPER
UNTUK
MENGENDALIKAN

LAJU
ALIRAN
UDARA
DINGIN
MENUJU
ZONA

TERTENTU

PERANCANGAN
TATA
UDARA

1.  KENYAMANAN
DALAM
RUANGAN
UMUMNYA

10∘C
DI
BAWAH
SUHU
RATA‐RATA
TUBUH

MANUSIA
(±
26
∘C)

2.  PADA
BANGUNAN
PERKANTORAN,
MALL,
DSB

YANG
MENGGUNAN
AC
CENTRAL,
AHU
DAPAT

DITEMPATKAN
DI
SETIAP
LANTAI,
ATAU
1
AHU

UNTUK
2/LEBIH
LANTAI

3.  HOTEL,
ASRAMA,
RUMAH
SAKIT
UMUMNYA

MENGGUNAKAN
UNIT
FAN
COIL
DI
SETIAP

RUANGAN,
DAN
AC
PAKET
PADA
RUANGAN

BESAR