Application Wiring
The BEC Apartment Entry Intercoms provide two- Suite/Apartment Stations
way communications between the building entrance and Stations may be connected in risers using the following
each suite. Hands-free loudspeaker operation at the cable configurations:
entrance/lobby panel and push button controlled
communication at the suite/apartment locations provide 3-wire stations: 1 twisted pair #22 AWG, plus 1
for easy operation. Controlled door entry is permitted by conductor #22 AWG per station in riser.
push button operation at the suite in conjunction with 4-wire stations: 1 twisted pair #22 AWG, plus 1
electric door release. conductor #22AWG, plus 1 conductor #22 AWG per
Optional equipment is available to provide additional station in riser.
functionality, such as post office key door release, 5-wire stations: 1 twisted pair #22 AWG, plus 2
additional entrance panels, strobe light call conductor #22 AWG, plus 1 conductor #22 AWG per
indication and auxiliary relay for ancillary device station in riser.
operation (bells, lights, etc.).
The maximum cable length is 400 feet (120 meters).
Additional risers may be added as needed. Station cables
Procedure must not be run in the same conduit with (or too close
to) electrical wiring or background music, and must
1. Read installation instructions to determine equipment not be close to fluorescent lighting or other electrical
location and installation methods. equipment. Failing to observe this requirement can
2. Install housings (or back boxes) and wiring. result in noise entering the intercom audio. Ensure that
3. Check wiring, connect and install equipment. sufficient amounts of cable are left in the back box to
4. Apply power and check operation. make connections to stations.
Transformer
Equipment Location Cable wiring must be 2 conductor #18 AWG with a
maximum cable length of 80 feet (25 meters). If using
Suite/Apartment Stations #14 AWG wire, this distance can be extended to 200
Locate suite stations (also known as remote stations) feet (60 meters). Route cable away from suite station
where convenient for use. Install a housing or back box wiring and maintain a minimum of 3 feet (1 meter) of
at the desired location. clearance between the transformer and the amplifier.
Entrance/Lobby Panel Door Release
Use the flush housing and trim frame for flush wall Cable wiring must be 2 conductor #18 AWG with a
mounting. Locate the entrance panel where it is maximum length of 50 feet (15 meters). See Figure 2
sheltered from weather. on page 5 for specifics of each door control unit
configuration. Note: An SS106 transformer must be
Intercom Amplifier used for 24 VAC doorstrike and 12 VDC Maglock
Install the amplifier inside the entrance panel when applications (8 volt tap required).
using a flush mount housing. The amplifier must be
installed outside the entrance panel when using a
surface box and frame. Refer to Connections section,
item #3, on page 2 for further details.
BEC quality system is registered by UL® to the ISO 9001 standard. (Reference #10001510.)
BEC - Williamsville, NY 14221
Phone: (888) 556-3998 or (716) 689-0871
www.becaudio.com
Connections Postal Timer Set SW4 to ON (right) and SW5 to OFF
(left) to make postal control timer
Before connecting to unit and applying power, verify that independent at 25 seconds
wires are free from shorts and grounds. Make connections
as per Figure 1 on page 4. Observe the following notes: Amp Compatible Set SW4 to OFF (left) and SW5
to ON (right) for PK543 drop-in
1. Do not apply power to the transformer primary until replacement*
the entire system has been installed and checked for
shorts and grounds. The common wires connecting to Door Hold Time Out Set SW6 to OFF (left) to activate this
terminals 1, 2, 3, E and 5 must show open circuit when feature
tested with an ohmmeter. Talk Interlock Set SW7 to OFF (left) to activate this
2. Use twisted pair wiring as shown. Do not interchange feature (available for 4-wire stations
wires or reverse polarity. only)
3. You may install intercom amplifier inside the * For Amp Compatible mode, set SW4 OFF, SW5 ON, SW6
entrance panel when using the flush housing. If it is ON & SW7 ON. Also remove JP5 shunt, set J2 to shunt 1–
necessary to install the amplifier elsewhere due to 2 and set J1 shunt to 2–3.
temperature extremes (operating temperature range The Entrance Tone setting, when active, will generate a user
is 0–30°C) or because the entrance panel is not large feedback tone at the entrance panel when users press call
enough to house the amplifier, then use a 2 conductor buttons. If the warble tone is in use and the entrance tone
shielded cable for the entrance panel speaker feature is active, the tone will also be heard through the
(connect shield drain to amplifier terminal G). entrance panel speaker when the call button is pressed.
4. The amplifier must be located at least 3 feet (1 meter) The Door Hold Time Out setting, when active, will allow the
from the transformer or other electrical devices. door control device (doorstrike, maglock, etc.) to time out
5. Do not run wiring for station common wires and entrance normally, despite the door button being held at the suite.
panel speaker in the same cable and/or conduit. This Safety Tip: The Talk Interlock setting, when active, will
will cause feedback on the system. require that the talk button (at the suite) is pressed before
6. Door release wiring should be run separate from the door button will activate the door control device.
entrance panel speaker wiring.
Optional Accessories
Shunt and Dipswitch Settings Install optional accessories according to the instructions
Set the dipswitches on the amplifier as per application provided.
requirements. See also Figure 4 on page 7. The select-
able features and controls are as follows:
Finish & Test Installation
Shunt JP5 Install for maglock applications. Maximum
current for maglock is 500 mA at 12 VDC, or 1. Confirm that all equipment is properly installed.
250 mA at 24 VDC. 2. Connect power to transformer primary (120 VAC), and
Shunt J2 Place shunt across: 1–2 for doorstrike ensure that local electrical codes have been complied
applications; 2–3 for maglock applications with.
Shunt J1 Place shunt across: 1–2 for +12 VDC maglock; 3. At the entrance panel, push each button and verify that
2–3 for +24 VDC maglock or AC/DC doorstrike the correct suite is called.
applications 4. At each suite, push the talk and listen buttons to com-
Short Door Time Set SW1 to ON (right) and SW2 to OFF municate with a person at the entrance panel. Then
(left), 2 seconds push the door button to confirm that the door release
operates correctly.
Medium Door Time Set SW1 to OFF (left) and SW2 to ON
(right), 10 seconds
Adjustments
Long Door Time Set SW1 to OFF (left) and SW2 to OFF
(left), 25 seconds Voice Volume and Tone Volume can be adjusted on the
amplifier, via the access hole, with a small screwdriver.
Entrance Tone Set SW3 to ON (right) to activate this
feature—must use warble tone
ENTRY PANEL
(Typical)
16 VAC CONNECT
See note #4 Apartment Call Buttons TO 120 VAC
3 Wire 4 Wire 5 Wire
SS102A
Intercom Intercom Intercom TRANSFORMER
#18 AWG Wire
Tone in
Switched Audio
Audio Common
Tone in
Audio to station
Audio from station
Audio Common
Tone in
5 Wire sta. door release
Audio to station
Audio from station
Audio Common
Amplifier
X 5 1 X 3 2 1 X E/4 3 2 1
L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power
D BRN Switched AC door release
K RED AC Input (Common)
Twisted Pair
C ORG AC Input
Twisted Pair Twisted Pair P WHT/BLK Strobe (LI404) power (+24VDC)
G ORG/BLK Entry speaker common
A BLK Entry speaker switched audio
E WHT 5 Wire station door release
5 GRN 3 wire station audio
3 GRY Audio to station
2 VIO Audio from station
1 BLU Audio Common
ZW RED/WHT Warble tone out
Z BRN/WHT Tone out
(Optional)
Notes: Twisted Pair
16 VAC Tap
Common
CONNECT TO 16 VAC CONNECT TO
120 VAC 120 VAC
8 VAC Tap
SS106 SS102A
TRANSFORMER TRANSFORMER
#18 AWG Wire #18 AWG Wire
Amplifier Maglock
IL826 PK543A Doorstrike Applications 2 Rev2 102008 1
Amplifier
L- YEL (-) DC Door power L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power L+ YEL/BLK (+) DC Door power
LP D BRN Switched AC door release D BRN Switched AC door release
K RED AC Input (Common) K RED AC Input (Common)
8 C ORG AC Input C ORG AC Input
4 pin header JP3, P WHT/BLK Strobe (LI404) power (+24VDC) P WHT/BLK Strobe (LI404) power (+24VDC)
located in front of G ORG/BLK Entry speaker common G ORG/BLK Entry speaker common
main connector. A BLK Entry speaker switched audio A BLK Entry speaker switched audio
E WHT 5 Wire station door release E WHT 5 Wire station door release
5 GRN 3 wire station audio 5 GRN 3 wire station audio
3 GRY Audio to station 3 GRY Audio to station
2 VIO Audio from station 2 VIO Audio from station
1 BLU Audio Common 1 BLU Audio Common
ZW RED/WHT Warble tone out ZW RED/WHT Warble tone out
Z BRN/WHT Tone out Z BRN/WHT Tone out
16 VAC Tap
CONNECT TO CONNECT TO
Common
120 VAC 16 VAC
8 VAC Tap 120 VAC
SS106 SS102A
TRANSFORMER TRANSFORMER
#18 AWG Wire #18 AWG Wire
T1 4 Wire
Intercom
T2
Station
D- LED Power Calculations for Door Switch:
16 VAC LN Each apartment station with a door indicator LED will draw 17mA
F+
SS102A when the door switch closes (caused by the actual building door
LP
TRANSFORMER F being opened). The amplifier can supply a maximum of
F 20 apartment stations. If an external power supply is used then
Tone in
Audio to station
Audio from station
Audio Common
X 3 2 1
the overall number of apartment stations can be multiplied by
Amplifier
L- YEL (-) DC Door power
Model F and S Stations L+ YEL/BLK (+) DC Door power
LP
D BRN Switched AC door release
K RED AC Input (Common)
8
4 Wire C ORG AC Input
4 pin header JP3, P WHT/BLK Strobe (LI404) power (+24VDC)
Intercom located in front of G ORG/BLK Entry speaker common
Station main connector. A BLK Entry speaker switched audio
E WHT 5 Wire station door release
Note: LP and 8 are each available on two
5 GRN 3 wire station audio
LN pins of the JP3 connector. Brackets are
3 GRY Audio to station
provided to identify.
2 VIO Audio from station
LP 1 BLU Audio Common
ZW RED/WHT Warble tone out
Z BRN/WHT Tone out
Tone in
Audio to station
Audio from station
Audio Common
X 3 2 1 door switch current
CONNECT TO
16 VAC
120 VAC
SS102A
TRANSFORMER
#18 AWG Wire
Figure 4— Amplifier Shunts and Settings
CONNECTORS
LP
J2
8
D
K
Intercom Amplifier
C
A
ZW
Z
Audio to station
Audio Common
P +24V
Tone in
SPEAKER
A
BEFORE ATTACHING
LP & 8 Connector P.O. LOCK (4)
TRANSFORMER
E
5
WARNING
3 COMMON X 3 2 1
2 WIRES
Main Connector 1
ZW BUZZ 1
Z BUZZ 2
SEE MANUAL FOR DETAILS
1 B
6 DOOR HOLD TIMEOUT
Dipswitch TONE 7 TALK INTERLOCK
For drop-in replacement set: SW4 OFF,
VOLUME SW5 ON, SW6 ON & SW7 ON Shunts:
JP5 remove, J2 1-2 & J1 2-3 A
C X
A signal relay is used in conjunction
with various open-voice and
handset apartment intercom and
video-intercom stations. The relay
will provide a momentary dry
contact relay closure, when the
station is called, to operate ancillary
devices such as strobes, bells or
lights for handicapped tenants.
Dipswitch Settings: (right and left are referenced from the view above)
Short Door Time - set SW1 to ON (right) and SW2 to OFF (left), 2 seconds
Medium Door Time - set SW1 to OFF (left) and SW2 to ON (right), 10 seconds
Long Door Time - set SW1 to OFF (left) and SW2 to OFF (left), 25 seconds
Entrance Tone - set SW3 to ON (right) to activate this feature
Postal Timer - set SW4 to ON (right) and SW5 to OFF (left) to make postal control timer
independent at 25 seconds
Amp Compatible* - set SW4 to OFF (left) and SW5 to ON (right) to make unit for drop-in
replacement for amplifier
Door Hold Time Out - set SW6 to OFF (left) to activate this feature
Talk Interlock - set SW7 to OFF (left) to activate this feature (available for 4-wire stations only)
* - For Amp Compatible mode, set SW4 OFF, SW5 ON, SW6 ON & SW7 ON.
Also remove JP5 shunt, set J2 to shunt 1 - 2 and set J1 shunt to 2 - 3.
Talk SS102A
TRANSFORMER
Door
Listen
16V AC Doorstrike Configuration
Audio Common
Tone in
Audio to station
Audio from station
Amplifier
X 3 2 1
L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power
D BRN Switched AC door release
K RED AC Input (Common)
C ORG AC Input
P WHT/BLK Strobe (LI404) power (+24VDC)
G ORG/BLK Entry speaker common
A BLK Entry speaker switched audio
E WHT 5 Wire station door release
5 GRN 3 wire station audio
3 GRY Audio to station
2 VIO Audio from station
1 BLU Audio Common
ZW RED/WHT Warble tone out
Z BRN/WHT Tone out
Application 6. From each entrance door release, run 1 cond. #18 to the
2-DR and 1 cond. #18 to the amplifier.
The 2-DR Dual Entrance Control Unit provides a means to
connect BEC Apartment Intercom amplifiers to more than 7. If a Post Office (P.O.) lock adapter is used, run 1 cond. #18
one entrance. Voice and door release functions are to the amplifier, and 1 cond. #18 to the associated door
automatically transferred to the calling entrance. The release from the P.O. lock adapter. In the wiring diagram,
quantity of 2-DRs needed is equal to one less than the the P.O. lock adapter is shown connected to door release
number of entrances. #1, but it may be connected to whichever door release is
required.
Procedure
Connections
Warning: This switching unit will not function unless
programmed for use—see Test Step #1. 1. Make connections as shown on the wiring diagram for
the amplifier being used. (For the intercom amplifier,
1. Determine equipment location. refer to Figure 1, Figure 2 and Figure 3. If more than two
2. Install wiring. 2-DRs are used, break the connections going from the 2-
3. Install equipment. DRs outside the dashed lines to the amplifier and insert
4. Check wiring and make connections. the wiring shown inside the dashed lines for any
5. Apply power and check operation. additional 2-DRs.
2. If a P.O. lock adapter is used, do not connect it until a P.O.
Equipment Location lock is obtained from the post office. When ready, make
Locate the 2-DR within 3' (1 m) of the intercom amplifier. If connections as shown on the appropriate wiring diagram.
more than one 2-DR is used, install them all in the same
3. Connect transformer to power source and follow the test
area. Keep the 2-DR away from direct heat or extreme cold.
procedures in the next section.
Operating temperature should be between 10°F and 90°F.
Test
Wiring
After performing the test required in the amplifier’s
1. The first 2-DR will support two entrances; each addi-
instructions, do the following:
tional 2-DR will support one additional entrance. For
example, a three-entrance system will have two 2-DRs. 1. The 2-DR must be programmed to operate with the
See Figure 2 for an example with additional entrances. amplifier being used. Locate the programming switch and
set switches as follows.
2. Wire the suite station common wires to the amplifier, and
wire the power transformer according to instructions sup- To use the intercom amplifier, set switches 2 and 4 on
plied with the amplifier. and switches 1, 3 and 5 off. Failure to set the
programming switches properly will result in faulty
3. If more than one 2-DR is used, run 1 cond. #18 plus 7
operation, but will not cause permanent damage to the 2-
cond. #22 between 2-DRs. Run 3 cond. #18 plus 3 cond.
DR.
#22 from the last 2-DR to the amplifier.
2. Perform tests required in the amplifier’s instructions, then
4. Run 2 cond. #22 twisted shielded (2 cond. #22, plus 2
at each entrance, press a call button and observe the fol-
cond. #22 shielded for 205 amplifiers) from each
lowing:
entrance panel to the associated 2-DR.
a. The buzz tone should be heard at the called suite station.
5. Run multi-cond. #22 cable (use 1 cond. per suite
station) from entrance panel to entrance panel, and from b. If the Entrance Tone is enabled at the amplifier, then
one entrance panel to the suite stations, as required by the buzz tone should be heard at the entrance panel.
instructions supplied with amplifier.
2-DR
!!!!!!!
TRANSFER RELAY
(Z2) (Z1)
D1 BLUE / WHITE
D2 GREEN / WHITE
D0 YELLOW / WHITE
S1 ORANGE / WHITE #18 P.O.LOCK
S2 RED / WHITE
S0 BROWN / WHITE ADAPTER
M1 WHITE
M2 BLACK
M0 GREY
Y1 BROWN
Y2 VIOLET
R BLUE 16 VOLT
Z1 GREEN TRANSFORMER
Z2 YELLOW
C ORANGE CONNECT TO
(D1) K RED 117 VAC
DOOR DOOR
RELEASE RELEASE #18
(D2) (K) #18
(K)
NOTES: #18
1. USE #22 WIRE UNLESS SHOWN OTHERWISE. TWO ENTRANCE
AMPLIFIER
TO REMOTE STATION
X TERMINALS L- YELLOW
L+ YELLOW/BLACK
D BROWN
K RED
C ORANGE
#18 V
PUSH BUTTONS PUSH BUTTONS PUSH BUTTONS G ORANGE/BLACK
A BLACK
E WHITE
5 GREEN
3 GREY
2 VIOLET
1 BLUE
ZW RED/WHITE
2-DR 2-DR Z BROWN/WHITE
Figure 3—Using a 502 Connector to Interconnect the 2-DR and the Amplifier
CONNECTORS
Explanation: LP
LED = POWER
JP5 1 2 3 1-2 DOOR STRIKE
J2 2-3 MAGLOCK
1 2 3 1-2 +12V DC OUT
J1 2-3 +24V DC OUT
L-
DC DOOR
502 L+ VOICE
6 Pin Connector
16 Pin Connector D AC DOOR VOLUME
K -- Red Blue & Yellow/White -- D K
Red & Red -- K TRANSFORMER
C -- Orange C
Z2 -- Yellow Orange & Orange -- C Plug P +24V
Brown/White -- A
VERIFY ALL CONNECTIONS
Z1 -- Green G
Here
To PK502B Connector
Y1 -- Brown 5
M0 -- Gray 3 COMMON
WARNING
M2 -- Black 2 WIRES
M1 -- White 1
S0 -- Brown/White ZW BUZZ 1
S2 -- Red/White
Z BUZZ 2
S1 -- Orange/White
SEE MANUAL FOR DETAILS
D0 -- Yellow/White SWITCH FUNCTIONS
D2 -- Green/White 1 SHORT DOOR TIME
2 MEDIUM DOOR TIME
D1 -- Blue/White 1 AND 2 OFF = LONG 3 ENTRANCE TONE
DOOR TIME 4 POSTAL TIMER
5 PK543 COMPATIBLE
6 DOOR HOLD TIMEOUT
TONE 7 TALK INTERLOCK
Notes:
1.To convert a 502 to CT502, simply cut off the 6 pin connector.
2. The "Z" output can be used by relocating the Green & Green wire combination to the
empty "Z" opening on the 6 pin connector.
3. Additional wires are provided on the 6 pin connector (K, C, & ZW (or Z)) to facilitate
connection to additional PK502B units. If unused, these must be isolated and taped off.