Design requirement

Parameter Requirement
Focus range ± 10 mm
Focus resolution 5 µm
Position Accuracy 10 µm
Measurement Noise 1.0 µm
Mechanism Alignment tilt 30 arc-sec
Accuracy Alignment De-space ± 0.05 µm
Operate de-center 0.001 in.
Operate tilt 1.5 arc-min
Scan rate (minimum ) 10 µm/sec
Power 3 watts (peak)
Duty Cycle <1%
Jitter 0.020 µrad rms
Operating Temp 20° C ± 5° C
Survival Temp -35° C to 75° C
Mass, Mechanism 152 kg
Mass, Translating (Optic Assembly) 0.4 kg
Envelope 99 x 72.5 x 15 cm
Design life 12 years
Reliability ≥ 0.97
2. Material Use & Process

The material that this design use is Stone. The Stone type is Gravel. A practical and cheap solution.
The processes to make them. This design have been through Vitreous Enameling. It is the process
that painting with glass. The object being enamelled must be heated to the melting temperature of
the glass powder.

3. Concept Translation
FUNCTION Heat storage

OBJECTIVE Minimize unit cost

CONSTRAINTS Lower processing cost

FREE VARIABLES Cross section area, A

Stiebel Eltron ETC 170A Automatic


1. Design requirement
Parameter Requirement
Focus range ± 10 mm
Focus resolution 5 µm
Position Accuracy 10 µm
Measurement Noise 1.0 µm
Mechanism Alignment tilt 30 arc-sec
Accuracy Alignment De-space ± 0.05 µm
Operate de-center 0.001 in.
Operate tilt 1.5 arc-min
Scan rate (minimum ) 10 µm/sec
Power 4 watts (peak)
Duty Cycle <1%
Jitter 0.020 µrad rms
Operating Temp 20° C ± 5° C
Survival Temp -20° C to 60° C
Mass, Mechanism 81 kg
Mass, Translating (Optic Assembly) 0.29 kg
Envelope 58.5 x 70 x 17 cm
Design life 10 years
Reliability ≥ 0.96

2. Material use
In Stiebel Eltron, the material choice is Cement. There’s plenty of Cement types such as Portland
Cement, Quick Setting Cement and others. It is easy to shape and light. However, maximum working
temperature dangerously close to limit. This design have been through Vitreous Enameling. It is the
process that painting with glass. The object being enamelled must be heated to the melting
temperature of the glass powder

3. Concept Translation
FUNCTION Heat storage

OBJECTIVE Minimize the mass

CONSTRAINTS Length must specified

FREE VARIABLES Cross section area, A

Choice of material
Elnur CSH12A Automatic Combined

1. Design requirement
Parameter Requirement
Focus range ± 10 mm
Focus resolution 5 µm
Position Accuracy 10 µm
Measurement Noise 1.0 µm
Mechanism Alignment tilt 30 arc-sec
Accuracy Alignment De-space ± 0.05 µm
Operate de-center 0.001 in.
Operate tilt 1.5 arc-min
Scan rate (minimum ) 10 µm/sec
Power 4 watts (peak)
Duty Cycle <1%
Jitter 0.020 µrad rms
Operating Temp 20° C ± 5° C
Survival Temp -20° C to 60° C
Mass, Mechanism 81 kg
Mass, Translating (Optic Assembly) 0.29 kg
Envelope 58.5 x 70 x 17 cm
Design life 10 years
Reliability ≥ 0.96
2. Material Use
For Elnur CSH12A, we will use Cast iron. Even the fact Cast Iron is heavy, the Maximum Service
Temperature (K) is more than 1000 K which is high enough for the storage heater. This design have
been through Vitreous Enameling. It is the process that painting with glass. The object being
enamelled must be heated to the melting temperature of the glass powder

3. Concept translation
FUNCTION Heat storage

OBJECTIVE Maximize heat stored per unit cost

CONSTRAINTS Maximum service temperature > heater temperature

FREE VARIABLES Cross section area, A

Choice of material