Sie sind auf Seite 1von 4

DPI CARRIED OUT FOR THE MONTH OF AUGUST AT PETROLEX TANK FARM: DPI

TECHNICIAN: DIMEJI POPOPOLA

DPI Number DPI Number


LOCATION DESCRIPTION Remarks LOCATION DESCRIPTION Remarks
carried out carried out

COMPLETED 6 JOINTS COMPLETED ON INLET


PUMP HOUSE PH/OUT/PMS-A1-A6 (6")
2 JOINTS
TANK 11 INLET NOZZLE/REINENFORCEMENT ONGOING NOZZLE/roof manhole
PLATE & ROOF VENT/ROOF
MANHOLE

COMPLETED 4 JOINTS COMPLETED ON INLET


PUMP HOUSE PH/OUT/AGO-A1-A6 (6") TANK 12 INLET NOZZLE/REINENFORCEMENT ONGOING
2 JOINTS NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE

COMPLETED 4 JOINTS COMPLETED ON INLET


PUMP HOUSE PH/OUT/DPK-A1-A6 (6") TANK 13 INLET NOZZLE/REINENFORCEMENT ONGOING
2 JOINTS NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE
10 JOINTS
COMPLETED COMPLETED, INLET NOZZLE/REINENFORCEMENT 3 JOINTS COMPLETED ON INLET
PUMP HOUSE PH/OUT/PMS-B1-B6 (6") TANK 14 ONGOING
2 JOINTS 2 JOINTS PLATE & ROOF VENT/ROOF NOZZLE
ONGOING MANHOLE

18 JOINTS COMPLETED ON
COMPLETED INLET
PUMP HOUSE PH/OUT/AGO-B1-B6 (6") TANK 15 ONGOING NOZZLE/REINENFORCEMENT
2 JOINTS INLET NOZZLE/REINENFORCEMENT PLATE & ROOF VENT/ROOF
PLATE & ROOF VENT/ROOF MANHOLE
MANHOLE

3 JOINT COMPLETED 3 JOINTS COMPLETED ON INLET


TANK 1 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE TANK 16 INLET NOZZLE/REINENFORCEMENT ONGOING NOZZLE
PLATE & ROOF VENT/ROOF PLATE & ROOF VENT/ROOF
MANHOLE MANHOLE

1 JOINT COMPLETED 3 JOINTS COMPLETED ON INLET


TANK 2 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE TANK 17 INLET NOZZLE/REINENFORCEMENT ONGOING NOZZLE
PLATE & ROOF VENT/ROOF PLATE & ROOF VENT/ROOF
MANHOLE MANHOLE

12 JOINTS 3 JOINTS COMPLETED ON INLET


TANK 3 INLET NOZZLE/REINENFORCEMENT ONGOING COMPLETED ON ROOF TANK 18 INLET NOZZLE/REINENFORCEMENT ONGOING NOZZLE
PLATE & ROOF VENT/ROOF VENTS AND MANHOLE PLATE & ROOF VENT/ROOF
MANHOLE MANHOLE
16 JOINTS COMPLETED ON
INLET
1 JOINT COMPLETED
TANK 4 ONGOING ON INLET NOZZLE TANK 19 ONGOING NOZZLE/REINENFORCEMENT
INLET NOZZLE/REINENFORCEMENT INLET NOZZLE/REINENFORCEMENT PLATE & ROOF VENT/ROOF
PLATE & ROOF VENT/ROOF PLATE & ROOF VENT/ROOF MANHOLE
MANHOLE MANHOLE

3 JOINTS COMPLETED
ON INLET 5 JOINTS COMPLETED ON INLET
TANK 5 ONGOING NOZZLE/REINENFORCE TANK 20 ONGOING NOZZLE
INLET NOZZLE/REINENFORCEMENT MENT PLATES INLET NOZZLE/REINENFORCEMENT
PLATE & ROOF VENT/ROOF PLATE & ROOF VENT/ROOF
MANHOLE MANHOLE

1 JOINT COMPLETED
TANK 6 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE

1 JOINT COMPLETED
TANK 7 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE

12 JOINTS
TANK 8 INLET NOZZLE/REINENFORCEMENT ONGOING COMPLETED ON ROOF
PLATE & ROOF VENT/ROOF VENTS AND MANHOLE
MANHOLE

1 JOINT COMPLETED
TANK 9 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE

3 JOINTS COMPLETED
TANK 10 INLET NOZZLE/REINENFORCEMENT ONGOING ON INLET NOZZLE
PLATE & ROOF VENT/ROOF
MANHOLE
RT work break down for the month of August RT
TECHNICIAN: Austin & Innocent

RT
LOCATION DESCRIPTION/PIPING CARRIED Remarks
OUT

PH/OUT/PMS-A1-A6
PUMP HOUSE
(6") 96 JOINTS COMPLETED

PH/OUT/AGO-A1-A6
PUMP HOUSE
(6") 96 JOINTS COMPLETED

PH/OUT/DPK-A1-A6
PUMP HOUSE
(6") 96 JOINTS COMPLETED

PH/OUT/PMS-B1-B6
PUMP HOUSE
(6") 96 JOINTS COMPLETED

PH/OUT/AGO-B1-B6
PUMP HOUSE
(6") 96 JOINTS COMPLETED
VBT work break down for the month of
August
VBT TECHNICIAN: Victor & Innocent
VBT carried
LOCATION DESCRIPTION Remarks
out

TANK 3 WELDS OF ROOF COMPLETED ACCEPTABLE

TANK 4 WELDS OF ROOF COMPLETED ACCEPTABLE

TANK 5 WELDS OF ROOF COMPLETED ACCEPTABLE

TANK 7 WELDS OF ROOF COMPLETED ACCEPTABLE

TANK 8 WELDS OF ROOF COMPLETED ACCEPTABLE