UMTS
UTRAN Operation, Administration,
Maintenance and Provisioning
UMTS-04.03

UTRAN OAM&P
401-382-290R04.03
Issue 1
August 2007

Alcatel-Lucent - Proprietary
This document contains proprietary information of Alcatel-Lucent and
is not to be disclosed or used except in accordance with applicable agreements.
Copyright © 2007 Alcatel-Lucent
Unpublished and Not for Publication
All Rights Reserved
See notice on first age

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their
respective owners.

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2007 Alcatel-Lucent. All Rights Reserved.

Notice

Every effort has been made to ensure that the information contained in this information product was accurate at the time of printing. However,
information is subject to change.

Conformance statements

There are no in-country requirements that are applicable for this Information Product.

Developed by Lucent Technologies.

Developed by Lucent Technologies.

Alcatel-Lucent - Proprietary
See notice on first page
Contents

About this information product


Purpose ......................................................................................................................................................................................... lvii

Reason for reissue .................................................................................................................................................................... lvii

Intended audience ..................................................................................................................................................................... lvii

How to use this information product ............................................................................................................................... lvii

Conventions used .................................................................................................................................................................... lviii

Information product support ............................................................................................................................................. lviii

Technical support ..................................................................................................................................................................... lix

How to order ............................................................................................................................................................................... lix

Related documentation ............................................................................................................................................................ lix

Related training ............................................................................................................................................................................ lx

Tasks ................................................................................................................................................................................................. lx

How to comment ......................................................................................................................................................................... lx

Part I: Hazard statements

1 Hazard statements

Overview ...................................................................................................................................................................................... 1-1

UTRAN hazard statements ................................................................................................................................................... 1-2

Part II: System description

2 UTRAN overview

Overview ...................................................................................................................................................................................... 2-1


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary iii
Issue 1, August 2007 See notice on first page
Contents

UMTS network .......................................................................................................................................................................... 2-2

UTRAN functions and interfaces ...................................................................................................................................... 2-5

Node B .......................................................................................................................................................................................... 2-7

Radio Network Controller .................................................................................................................................................... 2-8

Operation and Maintenance Center (OMC) ................................................................................................................ 2-10

UTRAN Transmission equipment ................................................................................................................................... 2-13

3 Node B mechanical structure

Overview ...................................................................................................................................................................................... 3-1

Structure of the Lucent UMTS Macrocell Indoor for +24V

Overview ...................................................................................................................................................................................... 3-3

Mechanical structure of the Lucent UMTS Macrocell Indoor .............................................................................. 3-4

Component numbering in the Lucent UMTS Macrocell Indoor .......................................................................... 3-8

Structure of the Lucent UMTS Macrocell Compact Indoor for +24V

Overview ................................................................................................................................................................................... 3-11

Mechanical structure of the Lucent UMTS Macrocell Compact Indoor ........................................................ 3-12

Component numbering in the Lucent UMTS Macrocell Compact Indoor .................................................... 3-16

Structure of the UMTS Lucent Macrocell Compact Outdoor for +24V

Overview ................................................................................................................................................................................... 3-18

Mechanical structure of the Lucent UMTS Macrocell Compact Outdoor ..................................................... 3-19

Component numbering in the Lucent UMTS Macrocell Compact Outdoor ................................................. 3-23

Structure of the UMTS Lucent UMTS Modular Cell Outdoor for +24V

Overview ................................................................................................................................................................................... 3-25

Mechanical structure of the UMTS Modular Cell Outdoor ................................................................................. 3-26

Component numbering in the UMTS Modular Cell Outdoor for +24 V ....................................................... 3-32

Structure of the UMTS Lucent Microcell for +24V

Overview ................................................................................................................................................................................... 3-35

...................................................................................................................................................................................................................................
iv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Mechanical structure of the Lucent UMTS Microcell Outdoor ......................................................................... 3-36

Component numbering in the Lucent UMTS Microcell Outdoor ..................................................................... 3-41

4 RNC mechanical structure

Overview ...................................................................................................................................................................................... 4-1

UMTS RNC mechanical description ................................................................................................................................ 4-2

cPSB chassis and components ............................................................................................................................................ 4-6

cPSB chassis configuration .................................................................................................................................................. 4-8

Part III: Performing OAM&P on the UTRAN

5 UTRAN tools

Overview ...................................................................................................................................................................................... 5-1

Maintenance terminals ........................................................................................................................................................... 5-2

Orthogonal Channel Noise Simulator .............................................................................................................................. 5-4

RF trace ........................................................................................................................................................................................ 5-6

HSDPA Orthogonal Channel Noise Simulator ............................................................................................................. 5-7

6 Radio frequencies

Overview ...................................................................................................................................................................................... 6-1

Modifying frequency for Node B cells

Overview ...................................................................................................................................................................................... 6-2

Verify RNC configured frequency .................................................................................................................................... 6-3

Modify Node B frequency - CLI ....................................................................................................................................... 6-5

Modify Node B frequency - GUI ...................................................................................................................................... 6-8

New frequency configuration

Overview ................................................................................................................................................................................... 6-11

Preliminary information ...................................................................................................................................................... 6-12

Add a new frequency ........................................................................................................................................................... 6-14

Check RNC configured frequency .................................................................................................................................. 6-16

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary v
Issue 1, August 2007 See notice on first page
Contents

RNC Reset ................................................................................................................................................................................ 6-18

RNCTRACE Reset ................................................................................................................................................................ 6-20

7 E1T1 growth

Overview ...................................................................................................................................................................................... 7-1

E1T1 growth ............................................................................................................................................................................... 7-2

8 SSH and Telnet connections

Overview ...................................................................................................................................................................................... 8-1

SSH cut-through to RNC ...................................................................................................................................................... 8-2

Telnet to a Node B ................................................................................................................................................................. 8-3

9 Recommended OMC filters

Overview ...................................................................................................................................................................................... 9-1

Recommended filters ............................................................................................................................................................. 9-2

Create filter - critical alarms ............................................................................................................................................... 9-3

Create filter - critical and major alarms ......................................................................................................................... 9-4

Create filter - all alarms during shift ............................................................................................................................... 9-5

Create filter - acknowledged alarm by user .................................................................................................................. 9-7

Create filter - unacknowledged alarms ............................................................................................................................ 9-9

10 The UTRAN Managed Information Model (MIM)

Overview ................................................................................................................................................................................... 10-1

Introduction

Overview ................................................................................................................................................................................... 10-2

The UTRAN information model ..................................................................................................................................... 10-3

MIBs in the Lucent UTRAN ............................................................................................................................................ 10-4

MIB contents ........................................................................................................................................................................... 10-6

Working with the UTRAN MIB ...................................................................................................................................... 10-8

...................................................................................................................................................................................................................................
vi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Information Models

Overview ................................................................................................................................................................................... 10-9

Introduction ............................................................................................................................................................................ 10-10

SNM information model ................................................................................................................................................... 10-11

RNC Information model ................................................................................................................................................... 10-13

Node B information model ............................................................................................................................................. 10-16

Part IV: Fault Management

11 Principles of maintenance

Overview ................................................................................................................................................................................... 11-1

UTRAN fault-management architecture ....................................................................................................................... 11-2

UTRAN alarm parameters ................................................................................................................................................. 11-5

UTRAN alarm thresholds ................................................................................................................................................... 11-8

12 Preventive maintenance

Overview ................................................................................................................................................................................... 12-1

Preventive maintenance schedule .................................................................................................................................... 12-2

Check UTRAN status .......................................................................................................................................................... 12-3

Check RF coverage ............................................................................................................................................................... 12-7

13 Corrective maintenance - alarm surveillance

Overview ................................................................................................................................................................................... 13-1

Day to day alarm surveillance

Overview ................................................................................................................................................................................... 13-2

Alarm surveillance process ................................................................................................................................................ 13-3

Open the fault manager ....................................................................................................................................................... 13-6

Open standard alarm tables ............................................................................................................................................... 13-7

Open alarm overload filter ................................................................................................................................................. 13-9

Close alarm overload filter .............................................................................................................................................. 13-11

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary vii
Issue 1, August 2007 See notice on first page
Contents

Acknowledge an active alarm ........................................................................................................................................ 13-12

Suppress alarms on a Node B or an RNC

Overview ................................................................................................................................................................................. 13-13

Create an alarm suppression filter ................................................................................................................................ 13-14

Activate alarm suppression ............................................................................................................................................. 13-16

Deactivate alarm suppression ......................................................................................................................................... 13-18

Retrieve current alarm suppression settings ............................................................................................................. 13-20

Modify an alarm suppression filter .............................................................................................................................. 13-22

Delete an alarm suppression filter ................................................................................................................................ 13-24

Alarm suppression attributes .......................................................................................................................................... 13-26

14 Corrective maintenance - OMC alarm clearance procedures

Overview ................................................................................................................................................................................... 14-1

NE communication establishment failure .................................................................................................................... 14-2

Event-driven overload on single NE ............................................................................................................................. 14-6

Heartbeat failed ....................................................................................................................................................................... 14-8

Heartbeat failed: NE type mismatch ........................................................................................................................... 14-12

Heartbeat failed: NE version mismatch ..................................................................................................................... 14-14

Invalid NE communication parameters ...................................................................................................................... 14-16

Event capacity exceeded .................................................................................................................................................. 14-17

Alarm information out of sync ...................................................................................................................................... 14-19

NE alarm synchronization in progress ....................................................................................................................... 14-21

NE communication establishment failure .................................................................................................................. 14-23

NE event could not be processed ................................................................................................................................. 14-27

Synchronization source mismatch ................................................................................................................................ 14-29

Unable to automatically delete PM data from NE .............................................................................................. 14-31

Unable to automatically retrieve PM data from NE ............................................................................................. 14-32

...................................................................................................................................................................................................................................
viii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Unmanaged state set to NE ............................................................................................................................................. 14-34

Remaining OMC alarm clearance procedures ......................................................................................................... 14-36

15 Corrective maintenance - Node B alarm clearance procedures

Overview ................................................................................................................................................................................... 15-1

General information

Overview ................................................................................................................................................................................. 15-14

Object relationships ............................................................................................................................................................ 15-15

Node B fault recovery actions ....................................................................................................................................... 15-16

Autonomous recovery actions taken by the Node B ............................................................................................ 15-20

Node B hardware replacement procedures ............................................................................................................... 15-21

ALDController alarms

Overview ................................................................................................................................................................................. 15-22

ALDController_communicationFailure ...................................................................................................................... 15-23

ALDController_hardwareFailure ................................................................................................................................... 15-25

ALDController_softwareDownloadFailure ............................................................................................................... 15-27

ALDController_softwareFailure .................................................................................................................................... 15-29

ALDController_softwareVersionMismatch ............................................................................................................... 15-31

ALDController_temperatureOutOfRange .................................................................................................................. 15-33

ALDController_unknownDeviceDetected ................................................................................................................. 15-35

AlarmHub alarms

Overview ................................................................................................................................................................................. 15-37

AlarmHub_communicationFailure ................................................................................................................................ 15-38

AlarmHub_externalAlarmPort0 ..................................................................................................................................... 15-40

AlarmHub_externalAlarmPort1 ..................................................................................................................................... 15-42

AlarmHub_externalAlarmPort2 ..................................................................................................................................... 15-44

AlarmHub_externalAlarmPort3 ..................................................................................................................................... 15-46

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary ix
Issue 1, August 2007 See notice on first page
Contents

AlarmHub_externalAlarmPort4 ..................................................................................................................................... 15-48

AlarmHub_externalAlarmPort5 ..................................................................................................................................... 15-50

AlarmHub_externalAlarmPort6 ..................................................................................................................................... 15-52

AlarmHub_externalAlarmPort7 ..................................................................................................................................... 15-54

AmpShelfFan alarms

Overview ................................................................................................................................................................................. 15-56

AmpShelfFan_equipmentFault ....................................................................................................................................... 15-57

CPC alarms

Overview ................................................................................................................................................................................. 15-59

CPC_communicationFailure ........................................................................................................................................... 15-60

CPC_configurationMismatch .......................................................................................................................................... 15-62

CPC_dCOutputFailure ....................................................................................................................................................... 15-64

CPC_lowDCInput ................................................................................................................................................................ 15-66

CPC_overTemperature ....................................................................................................................................................... 15-68

CPRIPort alarms

Overview ................................................................................................................................................................................. 15-70

CPRIPort_fibreLOF ............................................................................................................................................................ 15-71

CPRIPort_fibreLOS ............................................................................................................................................................ 15-72

CPRIPort_fibreRAI ............................................................................................................................................................. 15-73

CPRIPort_fibreSAPDefect ............................................................................................................................................... 15-74

CPRIPort_fibreSigLow ..................................................................................................................................................... 15-75

CPRIPort_transmitterSwitchOff .................................................................................................................................... 15-76

CTU alarms

Overview ................................................................................................................................................................................. 15-78

CTU_boardGenericMismatch ......................................................................................................................................... 15-80

CTU_clockFailure15Mhz ................................................................................................................................................. 15-82

...................................................................................................................................................................................................................................
x Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

CTU_clockFailure30_72Mhz .......................................................................................................................................... 15-84

CTU_communicationFailure ........................................................................................................................................... 15-86

CTU_configurationMismatch ......................................................................................................................................... 15-88

CTU_flywheelStart ............................................................................................................................................................. 15-90

CTU_flywheelTimeLimitReached ................................................................................................................................ 15-92

CTU_frequencyOutOfRange ........................................................................................................................................... 15-94

CTU_gPSAntennaFailure ................................................................................................................................................. 15-96

CTU_gPSReceiverFailure ................................................................................................................................................ 15-98

CTU_hardwareModelMismatch .................................................................................................................................. 15-100

CTU_inactive ...................................................................................................................................................................... 15-102

CTU_initialisationFailure ............................................................................................................................................... 15-104

CTU_lossOfClockSourceSynchronisation ............................................................................................................... 15-106

CTU_maintenanceRequested ........................................................................................................................................ 15-108

CTU_messageThrottleOn ............................................................................................................................................... 15-110

CTU_noOMConfiguredInDatabase ............................................................................................................................ 15-112

CTU_phaseLockLoopFailure ........................................................................................................................................ 15-114

CTU_selfTestFailure ........................................................................................................................................................ 15-116

CTU_syncSourceMismatch ........................................................................................................................................... 15-118

CTU_temperatureOutOfRange .................................................................................................................................... 15-120

CTU_timeOfDayDataInvalid ........................................................................................................................................ 15-122

CTU_underTemperature ................................................................................................................................................. 15-124

CTU_waitingForClockSignal ....................................................................................................................................... 15-126

Cell alarms

Overview .............................................................................................................................................................................. 15-128

Cell_blockRequestTimerExpiry ................................................................................................................................... 15-129

Cell_configurationMismatch ........................................................................................................................................ 15-131

Cell_powerTestThresholdExceeded ........................................................................................................................... 15-133


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xi
Issue 1, August 2007 See notice on first page
Contents

Cell_rETNotSupported ................................................................................................................................................... 15-136

Cell_receiveAntennaTestThresholdExceededOnAllAntennas ......................................................................... 15-138

Cell_receiveAntennaTestThresholdExceededOnAntenna1 ............................................................................... 15-140

Cell_receiveAntennaTestThresholdExceededOnAntenna2 ............................................................................... 15-142

Cell_temporarySoftwareFailure ................................................................................................................................... 15-144

DigitalShelfFan alarms

Overview .............................................................................................................................................................................. 15-146

DigitalShelfFan_equipmentFault ................................................................................................................................ 15-147

E1T1Port alarms

Overview .............................................................................................................................................................................. 15-149

E1T1Port_aISDetected .................................................................................................................................................... 15-150

E1T1Port_atmSyncLost .................................................................................................................................................. 15-152

E1T1Port_bitErrorRateGreaterThan1PerMillion .................................................................................................. 15-154

E1T1Port_bitErrorRateGreaterThan1PerThousand ............................................................................................. 15-156

E1T1Port_configurationMismatch ............................................................................................................................. 15-158

E1T1Port_frameLost ........................................................................................................................................................ 15-160

E1T1Port_frameMissed .................................................................................................................................................. 15-162

E1T1Port_frameSlip ........................................................................................................................................................ 15-164

E1T1Port_iMALinkAlarm ............................................................................................................................................. 15-166

E1T1port_localConfigurationFailure ......................................................................................................................... 15-168

E1T1Port_remoteAlarmIndication ............................................................................................................................. 15-170

E1T1Port_signalLost ....................................................................................................................................................... 15-172

E1T1Port_unexpectedIMAGroup ............................................................................................................................... 15-174

E3T3Port alarms

Overview .............................................................................................................................................................................. 15-176

E3T3Port_linkFailureAIS .............................................................................................................................................. 15-177

...................................................................................................................................................................................................................................
xii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

E3T3Port_linkFailureHBER ......................................................................................................................................... 15-179

E3T3Port_linkFailureLBER .......................................................................................................................................... 15-181

E3T3Port_linkFailureLOF ............................................................................................................................................. 15-183

E3T3Port_linkFailureLOS ............................................................................................................................................. 15-185

E3T3Port_linkFailureOOF ............................................................................................................................................ 15-187

E3T3Port_linkFailureRDI .............................................................................................................................................. 15-188

E3T3port_localConfigurationFailure ......................................................................................................................... 15-190

EthernetPort alarms

Overview .............................................................................................................................................................................. 15-192

EthernetPort_portFailure ................................................................................................................................................ 15-193

ExtRxAmp alarms

Overview .............................................................................................................................................................................. 15-194

ExtRxAmp_configurationMismatch .......................................................................................................................... 15-195

ExtRxAmp_equipmentFault .......................................................................................................................................... 15-197

ExtRxAmp_localConfigurationFailure ..................................................................................................................... 15-199

Filter alarms

Overview .............................................................................................................................................................................. 15-201

Filter_communicationFailure ........................................................................................................................................ 15-202

Filter_configurationMismatch ...................................................................................................................................... 15-204

Filter_dCConverterFailure ............................................................................................................................................. 15-206

Filter_hardwareModelMismatch ................................................................................................................................. 15-208

Filter_localConfigurationFailure ................................................................................................................................. 15-210

Filter_unknownHardwareModel .................................................................................................................................. 15-212

Frame alarms

Overview .............................................................................................................................................................................. 15-214

Frame_cabinetDoorOpen ............................................................................................................................................... 15-215

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xiii
Issue 1, August 2007 See notice on first page
Contents

Frame_cabinetHeaterFailure ......................................................................................................................................... 15-217

Frame_fanFault .................................................................................................................................................................. 15-219

Frame_heatManagementSystemCompressorFailure ............................................................................................ 15-221

Frame_heatManagementSystemControllerFailure ............................................................................................... 15-223

Frame_overTemperature ................................................................................................................................................. 15-225

Frame_underTemperature .............................................................................................................................................. 15-227

GRS alarms

Overview .............................................................................................................................................................................. 15-229

GRS_configurationMismatch ....................................................................................................................................... 15-230

GRS_firstPortNumberAlreadyInUse ......................................................................................................................... 15-232

GRS_gPSAntennaFailure ............................................................................................................................................... 15-234

GRS_gPSAntennaPositionUnknown ......................................................................................................................... 15-236

GRS_gPSReceiverFailure .............................................................................................................................................. 15-238

GRS_gPSReceiverUnavailable .................................................................................................................................... 15-240

GRS_satelliteHealthyThresholdExceededForAllVisibleSatellites .................................................................. 15-241

GRS_secondPortNumberAlreadyInUse .................................................................................................................... 15-243

GRS_selfSurveyFailed .................................................................................................................................................... 15-245

IMAGroup alarms

Overview .............................................................................................................................................................................. 15-247

IMAGroup_criticalGroupAlarm .................................................................................................................................. 15-248

IMAGroup_criticalGroupConfigurationAlarm ...................................................................................................... 15-250

IMAGroup_majorGroupAlarm .................................................................................................................................... 15-252

IMAGroup_noncriticalGroupConfigurationAlarm ............................................................................................... 15-254

IOU alarms

Overview .............................................................................................................................................................................. 15-256

IOU_communicationFailure .......................................................................................................................................... 15-258

...................................................................................................................................................................................................................................
xiv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

IOU_externalAlarmPort0 ............................................................................................................................................... 15-260

IOU_externalAlarmPort1 ............................................................................................................................................... 15-262

IOU_externalAlarmPort10 ............................................................................................................................................. 15-264

IOU_externalAlarmPort11 ............................................................................................................................................. 15-266

IOU_externalAlarmPort12 ............................................................................................................................................. 15-268

IOU_externalAlarmPort13 ............................................................................................................................................. 15-270

IOU_externalAlarmPort14 ............................................................................................................................................. 15-272

IOU_externalAlarmPort15 ............................................................................................................................................. 15-274

IOU_externalAlarmPort16 ............................................................................................................................................. 15-276

IOU_externalAlarmPort17 ............................................................................................................................................. 15-278

IOU_externalAlarmPort18 ............................................................................................................................................. 15-280

IOU_externalAlarmPort19 ............................................................................................................................................. 15-282

IOU_externalAlarmPort2 ............................................................................................................................................... 15-284

IOU_externalAlarmPort20 ............................................................................................................................................. 15-286

IOU_externalAlarmPort21 ............................................................................................................................................. 15-288

IOU_externalAlarmPort22 ............................................................................................................................................. 15-290

IOU_externalAlarmPort23 ............................................................................................................................................. 15-292

IOU_externalAlarmPort24 ............................................................................................................................................. 15-294

IOU_externalAlarmPort25 ............................................................................................................................................. 15-296

IOU_externalAlarmPort26 ............................................................................................................................................. 15-298

IOU_externalAlarmPort27 ............................................................................................................................................. 15-300

IOU_externalAlarmPort28 ............................................................................................................................................. 15-302

IOU_externalAlarmPort29 ............................................................................................................................................. 15-304

IOU_externalAlarmPort3 ............................................................................................................................................... 15-306

IOU_externalAlarmPort30 ............................................................................................................................................. 15-308

IOU_externalAlarmPort31 ............................................................................................................................................. 15-310

IOU_externalAlarmPort4 ............................................................................................................................................... 15-312


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xv
Issue 1, August 2007 See notice on first page
Contents

IOU_externalAlarmPort5 ............................................................................................................................................... 15-314

IOU_externalAlarmPort6 ............................................................................................................................................... 15-316

IOU_externalAlarmPort7 ............................................................................................................................................... 15-318

IOU_externalAlarmPort8 ............................................................................................................................................... 15-320

IOU_externalAlarmPort9 ............................................................................................................................................... 15-322

Iub interface alarms

Overview .............................................................................................................................................................................. 15-324

IubInterface_rNCCommunicationLost ...................................................................................................................... 15-325

NodeB alarms

Overview .............................................................................................................................................................................. 15-327

NodeB_alarmDefFileCorrupt ....................................................................................................................................... 15-328

NodeB_alarmDefFileMissing ....................................................................................................................................... 15-330

NodeB_databaseCleared ................................................................................................................................................. 15-332

NodeB_databaseRestoredFromSnapshot .................................................................................................................. 15-335

NodeB_filesystemNearingCapacity ........................................................................................................................... 15-337

NodeB_filesystemObjectCorrupt ................................................................................................................................ 15-339

NodeB_invalidSecurityDataDetected ........................................................................................................................ 15-341

NodeB_ipfwNatRulesAltered ....................................................................................................................................... 15-343

NodeB_nodeBTypeMismatch ....................................................................................................................................... 15-345

NodeB_snapshotFailed ................................................................................................................................................... 15-347

NodeB_unauthorizedLoginAttempt ........................................................................................................................... 15-349

NodeB_userPasswordLoginAttempt .......................................................................................................................... 15-351

OCM alarms

Overview .............................................................................................................................................................................. 15-353

OCM_boardGenericMismatch ..................................................................................................................................... 15-354

OCM_clockFailure30_72MHz ..................................................................................................................................... 15-356

...................................................................................................................................................................................................................................
xvi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

OCM_communicationFailure ....................................................................................................................................... 15-357

OCM_initialisationFailure ............................................................................................................................................. 15-359

OCM_lossOfForwardBusLink ..................................................................................................................................... 15-360

OCM_lossOfPulse ............................................................................................................................................................ 15-361

OCM_missingconfigurationData ................................................................................................................................ 15-362

OCM_selfTestFailure ....................................................................................................................................................... 15-364

OM alarms

Overview .............................................................................................................................................................................. 15-365

OM_clockFailure15Mhz ................................................................................................................................................ 15-366

OM_configurationMismatch ......................................................................................................................................... 15-368

OM_frequencyOutOfRange .......................................................................................................................................... 15-370

OM_hardwareModelMismatch .................................................................................................................................... 15-372

OM_inactive ........................................................................................................................................................................ 15-375

OM_maintenanceRequested .......................................................................................................................................... 15-377

OM_phaseLockLoopFailure ......................................................................................................................................... 15-380

OM_temperatureOutOfRange ...................................................................................................................................... 15-382

OM_underTemperature ................................................................................................................................................... 15-384

RETActuator alarms

Overview .............................................................................................................................................................................. 15-386

RETActuator_actuatorJam ............................................................................................................................................. 15-387

RETActuator_calibrationLost ....................................................................................................................................... 15-389

RETActuator_communicationFailure ........................................................................................................................ 15-391

RETActuator_deviceTypeMismatch .......................................................................................................................... 15-393

RETActuator_hardwareFailure .................................................................................................................................... 15-394

RETActuator_positionLost ............................................................................................................................................ 15-396

RETActuator_softwareFailure ...................................................................................................................................... 15-398

RETActuator_tiltAngleOutOfRange .......................................................................................................................... 15-400


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xvii
Issue 1, August 2007 See notice on first page
Contents

RFHead alarms

Overview .............................................................................................................................................................................. 15-402

RFHead_boardGenericMismatch .............................................................................................................................. 15-404

RFHead_clockFailure ...................................................................................................................................................... 15-406

RFHead_communicationFailure .................................................................................................................................. 15-407

RFHead_criticalTransmitterAlarm ............................................................................................................................. 15-409

RFHead_dCInputFailure ................................................................................................................................................. 15-411

RFHead_diversityImbalance ......................................................................................................................................... 15-412

RFHead_externalAlarmPort0 ....................................................................................................................................... 15-414

RFHead_externalAlarmPort1 ....................................................................................................................................... 15-415

RFHead_externalAlarmPort2 ....................................................................................................................................... 15-416

RFHead_externalAlarmPort3 ....................................................................................................................................... 15-417

RFHead_externalAlarmPort4 ....................................................................................................................................... 15-418

RFHead_externalAlarmPort5 ....................................................................................................................................... 15-419

RFHead_fibreLOF ............................................................................................................................................................ 15-420

RFHead_fibreLOS ............................................................................................................................................................ 15-422

RFHead_fibreRAI ............................................................................................................................................................. 15-424

RFHead_fibreSAPDefect ............................................................................................................................................... 15-426

RFHead_fibreSigLow ...................................................................................................................................................... 15-428

RFHead_initialisationFailure ........................................................................................................................................ 15-430

RFHead_noncriticalTransmitterAlarm ...................................................................................................................... 15-431

RFHead_overTemperature ............................................................................................................................................. 15-433

RFHead_rFOverdrive ...................................................................................................................................................... 15-435

RFHead_receiver1Failure .............................................................................................................................................. 15-436

RFHead_receiver2Failure .............................................................................................................................................. 15-437

RFHead_receiverFailure ................................................................................................................................................. 15-438

RFHead_selfTestFailure ................................................................................................................................................. 15-439


...................................................................................................................................................................................................................................
xviii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

RFHead_softwareFailure ................................................................................................................................................ 15-440

RFHead_temperatureOutOfRange .............................................................................................................................. 15-441

RFHead_txActivationFailure ........................................................................................................................................ 15-443

RFHead_underTemperature .......................................................................................................................................... 15-444

RFHead_vSWRAlarm ..................................................................................................................................................... 15-445

RFHead_warmup ............................................................................................................................................................... 15-446

Radio alarms

Overview .............................................................................................................................................................................. 15-447

Radio_applicationInsane ................................................................................................................................................ 15-449

Radio_boardGenericMismatch ..................................................................................................................................... 15-450

Radio_clockFailure30_72Mhz ..................................................................................................................................... 15-452

Radio_communicationFailure ....................................................................................................................................... 15-455

Radio_configurationMismatch ..................................................................................................................................... 15-457

Radio_criticalGainFailure .............................................................................................................................................. 15-459

Radio_digitalClippingDetected .................................................................................................................................... 15-461

Radio_diversityImbalance ............................................................................................................................................. 15-463

Radio_fPGAFailure .......................................................................................................................................................... 15-465

Radio_filterPanelRecordInvalid .................................................................................................................................. 15-467

Radio_hardwareModelMismatch ................................................................................................................................ 15-469

Radio_hwErrorDetectedByPlatformSw .................................................................................................................... 15-471

Radio_initialisationFailure ............................................................................................................................................. 15-473

Radio_internalGainFailure ............................................................................................................................................. 15-475

Radio_localConfigurationFailure ................................................................................................................................ 15-477

Radio_lossOfDemodulatorSynthesizerSynchronisation ..................................................................................... 15-479

Radio_lossOfForwardBusLink ..................................................................................................................................... 15-482

Radio_lossOfModulatorSynthesizerSynchronisation .......................................................................................... 15-484

Radio_lossOfPulse ............................................................................................................................................................ 15-487


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xix
Issue 1, August 2007 See notice on first page
Contents

Radio_lossOfReceiveSynthesizerSynchronisation ............................................................................................... 15-490

Radio_lossOfTransmitSynthesizerSynchronisation ............................................................................................. 15-493

Radio_majorGainFailure ................................................................................................................................................ 15-496

Radio_majorPlatformSwError ...................................................................................................................................... 15-499

Radio_majorTxSpectrumFailure ................................................................................................................................. 15-500

Radio_messageThrottleOn ............................................................................................................................................. 15-503

Radio_minorGainFailure ................................................................................................................................................ 15-505

Radio_missingConfigurationData ............................................................................................................................... 15-508

Radio_missingDelayCalibrationData ........................................................................................................................ 15-510

Radio_overTemperature .................................................................................................................................................. 15-512

Radio_portMapInvalid .................................................................................................................................................... 15-514

Radio_rFOverdrive ........................................................................................................................................................... 15-516

Radio_rFPathMismatch .................................................................................................................................................. 15-518

Radio_resyncOfPulse ....................................................................................................................................................... 15-520

Radio_rx1PathFaultDetected ........................................................................................................................................ 15-523

Radio_rx2PathFaultDetected ........................................................................................................................................ 15-525

Radio_samplingReceiverFailure .................................................................................................................................. 15-527

Radio_selfTestFailure ...................................................................................................................................................... 15-529

Radio_synthesizerFailure122Mhz ............................................................................................................................... 15-531

Radio_synthesizerFailure15Mhz ................................................................................................................................. 15-533

Radio_tDUCommunicationFailure ............................................................................................................................. 15-535

Radio_toneGeneratorFailure ......................................................................................................................................... 15-537

Radio_transmitGainLimitExceeded ........................................................................................................................... 15-539

Radio_transmitterSwitchFailure .................................................................................................................................. 15-542

Radio_transmitterSwitchOff ......................................................................................................................................... 15-544

Radio_txActivationMalfunction .................................................................................................................................. 15-546

Radio_underTemperature ............................................................................................................................................... 15-548


...................................................................................................................................................................................................................................
xx Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

RxAmp alarms

Overview .............................................................................................................................................................................. 15-550

RxAmp_equipmentFault ................................................................................................................................................ 15-551

RxAmp_initialisationFailure ......................................................................................................................................... 15-553

STM1OC3Port alarms

Overview .............................................................................................................................................................................. 15-555

STM1OC3Port_linkFailureAIS_L .............................................................................................................................. 15-556

STM1OC3Port_linkFailureAIS_P .............................................................................................................................. 15-558

STM1OC3Port_linkFailureLOF .................................................................................................................................. 15-560

STM1OC3Port_linkFailureLOP_P ............................................................................................................................. 15-562

STM1OC3Port_linkFailureLOS .................................................................................................................................. 15-564

STM1OC3Port_linkFailurePLM_P ............................................................................................................................ 15-566

STM1OC3Port_linkFailureRDI_L ............................................................................................................................. 15-568

STM1OC3Port_linkFailureRDI_P ............................................................................................................................. 15-570

STM1OC3Port_linkFailureSLU_P ............................................................................................................................. 15-572

STM1OC3port_localConfigurationFailure .............................................................................................................. 15-574

STM1OC3Port_pathTraceMismatch ......................................................................................................................... 15-576

STM1OC3Port_signalDegraded_L ............................................................................................................................ 15-578

STM1OC3Port_signalDegraded_P ............................................................................................................................. 15-580

STM1OC3Port_signalFailed_L ................................................................................................................................... 15-582

STM1OC3Port_signalFailed_P ................................................................................................................................... 15-584

TDU alarms

Overview .............................................................................................................................................................................. 15-586

TDU_applicationInsane .................................................................................................................................................. 15-587

TDU_boardGenericMismatch ...................................................................................................................................... 15-589

TDU_communicationFailure ........................................................................................................................................ 15-591

TDU_configurationMismatch ....................................................................................................................................... 15-593


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxi
Issue 1, August 2007 See notice on first page
Contents

TDU_criticalVoltageFailure .......................................................................................................................................... 15-595

TDU_filterPanelRecordInvalid .................................................................................................................................... 15-597

TDU_frequencySynthesizerFailure ............................................................................................................................ 15-599

TDU_heaterFailure ........................................................................................................................................................... 15-601

TDU_hwErrorDetectedByPlatformSw ..................................................................................................................... 15-603

TDU_initialisationFailure .............................................................................................................................................. 15-605

TDU_localConfigurationFailure .................................................................................................................................. 15-607

TDU_lossOfPulse ............................................................................................................................................................. 15-609

TDU_majorPlatformSwError ....................................................................................................................................... 15-612

TDU_messageThrottleOn .............................................................................................................................................. 15-614

TDU_portMapInvalid ...................................................................................................................................................... 15-616

TDU_selfTestFailure ........................................................................................................................................................ 15-618

TDU_temperatureOutOfRange .................................................................................................................................... 15-620

TDU_tssiDetectorFailure ............................................................................................................................................... 15-622

TxAmp alarms

Overview .............................................................................................................................................................................. 15-624

TxAmp_amplifierSwitchFailure .................................................................................................................................. 15-625

TxAmp_communicationFailure ................................................................................................................................... 15-627

TxAmp_configurationMismatch ................................................................................................................................. 15-629

TxAmp_equipmentFault ................................................................................................................................................. 15-631

TxAmp_externalAmplifierFailure .............................................................................................................................. 15-633

TxAmp_hardwareModelMismatch ............................................................................................................................. 15-635

TxAmp_incompletePredistortionCoefficients ........................................................................................................ 15-637

TxAmp_initialisationFailure ......................................................................................................................................... 15-639

TxAmp_localConfigurationFailure ............................................................................................................................ 15-641

TxAmp_messageThrottleOn ......................................................................................................................................... 15-643

TxAmp_missingPredistortionCoefficients ............................................................................................................... 15-645


...................................................................................................................................................................................................................................
xxii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

TxAmp_overTemperature .............................................................................................................................................. 15-647

TxAmp_rFOverdrive ....................................................................................................................................................... 15-649

TxAmp_selfTestFailure .................................................................................................................................................. 15-651

TxAmp_severeExternalAmplifierFailure ................................................................................................................. 15-653

TxAmp_underTemperature ............................................................................................................................................ 15-655

TxAmp_warmupFailure .................................................................................................................................................. 15-657

UCU alarms

Overview .............................................................................................................................................................................. 15-659

UCU_applicationInsane .................................................................................................................................................. 15-660

UCU_clockFailure30_72Mhz ....................................................................................................................................... 15-662

UCU_combinerToASICBusFailure ............................................................................................................................ 15-664

UCU_communicationFailure ........................................................................................................................................ 15-666

UCU_configurationMismatch ...................................................................................................................................... 15-668

UCU_criticalChannelElementFailure ........................................................................................................................ 15-670

UCU_criticalChannelElementSystemResourceFailure ....................................................................................... 15-672

UCU_excessiveDownlinkParityErrors ...................................................................................................................... 15-674

UCU_excessiveUplinkParityErrors ............................................................................................................................ 15-676

UCU_fPGAFailure ........................................................................................................................................................... 15-678

UCU_hwErrorDetectedByPlatformSw ..................................................................................................................... 15-681

UCU_initialisationFailure .............................................................................................................................................. 15-683

UCU_lossOfForwardBusLink ...................................................................................................................................... 15-685

UCU_majorChannelElementSystemResourceFailure ......................................................................................... 15-687

UCU_majorPlatformSwError ....................................................................................................................................... 15-689

UCU_selfTestFailure ....................................................................................................................................................... 15-691

UCU_voltageOutOfRange ............................................................................................................................................. 15-693

UCU_watchdogInitiatedReset ...................................................................................................................................... 15-695

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxiii
Issue 1, August 2007 See notice on first page
Contents

URC alarms

Overview .............................................................................................................................................................................. 15-697

URC_aTMOutOfCellDelineation ............................................................................................................................... 15-698

URC_applicationInsane .................................................................................................................................................. 15-700

URC_clockFailure30_72Mhz ....................................................................................................................................... 15-701

URC_configurationMismatch ....................................................................................................................................... 15-703

URC_hardwareModelMismatch .................................................................................................................................. 15-705

URC_hwErrorDetectedByPlatformSw ..................................................................................................................... 15-707

URC_localConfigurationFailure .................................................................................................................................. 15-709

URC_lossOfPulse .............................................................................................................................................................. 15-711

URC_majorPlatformSwError ....................................................................................................................................... 15-713

16 Corrective maintenance - RNC alarm clearance procedures

Overview ................................................................................................................................................................................... 16-1

General information

Overview ................................................................................................................................................................................. 16-14

RNC fault recovery actions ............................................................................................................................................. 16-15

Autonomous recovery actions taken by the RNC ................................................................................................. 16-18

RNC hardware replacement procedures ..................................................................................................................... 16-19

AC alarms

Overview ................................................................................................................................................................................. 16-20

AC_communicationFailure .............................................................................................................................................. 16-21

AC_softwareVersionMismatch ....................................................................................................................................... 16-23

CICC alarms

Overview ................................................................................................................................................................................. 16-24

CICC_degradeGroupMemberFault ............................................................................................................................... 16-25

CICC_escalatingRecovery ............................................................................................................................................... 16-27

...................................................................................................................................................................................................................................
xxiv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

CICC_failureGroupMemberFault .................................................................................................................................. 16-29

CICC_lossOfPower ............................................................................................................................................................. 16-31

CICC_lossOfSanity ............................................................................................................................................................. 16-33

CICC_lostCommunication ............................................................................................................................................... 16-35

CICC_maintenanceMode .................................................................................................................................................. 16-37

CICC_notInstalled ............................................................................................................................................................... 16-38

CICC_overTemperature .................................................................................................................................................... 16-40

CICC_overTemperatureInFlow ...................................................................................................................................... 16-42

CICC_overTemperatureOutFlow ................................................................................................................................... 16-44

CICCBPEtherPort alarms

Overview ................................................................................................................................................................................. 16-46

CICCBPEtherPort_communicationFailureESC1_2 ................................................................................................ 16-47

CICCBPEtherPort_communicationFailureESC1_21 ............................................................................................. 16-49

CICCBPEtherPort_communicationFailureESC2_2 ................................................................................................ 16-51

CICCBPEtherPort_communicationFailureESC2_21 ............................................................................................. 16-53

CICCBPEtherPort_linkFailure ....................................................................................................................................... 16-55

CICCBPEtherPort_restoreServiceFailure ................................................................................................................... 16-57

CICCProc alarms

Overview ................................................................................................................................................................................. 16-59

CICCProc_communicationFailure ................................................................................................................................ 16-60

CICCProc_communicationFailureLRM ..................................................................................................................... 16-62

CICCProc_configurationError ........................................................................................................................................ 16-64

CICCProc_cpuUsageOverload ....................................................................................................................................... 16-65

CICCProc_criticalSoftwareFailure ............................................................................................................................... 16-66

CICCProc_heartbeatFailure ............................................................................................................................................. 16-68

CICCProc_memoryBlockError ...................................................................................................................................... 16-70

CICCProc_memoryUsageOverload .............................................................................................................................. 16-72


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxv
Issue 1, August 2007 See notice on first page
Contents

CICCProc_resourceFailure .............................................................................................................................................. 16-73

CICCProc_restoreServiceFailure ................................................................................................................................... 16-75

CICCProc_softwareAssertError ..................................................................................................................................... 16-77

CICCProc_softwareVersionMismatch ......................................................................................................................... 16-79

CICCProc_standbyMateDown ....................................................................................................................................... 16-81

CICCProc_switchover ....................................................................................................................................................... 16-83

CICCProc_vitalResourceFailure .................................................................................................................................... 16-85

Cabinet alarms

Overview ................................................................................................................................................................................. 16-87

Cabinet_fanOrCktBreakerFailure .................................................................................................................................. 16-88

EDCH alarms

Overview ................................................................................................................................................................................. 16-89

EDCH_configurationRequestFailed ............................................................................................................................. 16-90

EDCH_resourceDegradation ........................................................................................................................................... 16-92

EDCH_resourceFailure ..................................................................................................................................................... 16-94

ESC alarms

Overview ................................................................................................................................................................................. 16-96

ESC_degradeGroupMemberFault ................................................................................................................................. 16-97

ESC_failureGroupMemberFault .................................................................................................................................... 16-99

ESC_lossOfPower ............................................................................................................................................................. 16-101

ESC_lossOfSanity ............................................................................................................................................................. 16-103

ESC_lostCommunication ............................................................................................................................................... 16-105

ESC_maintenanceMode .................................................................................................................................................. 16-107

ESC_notInstalled ............................................................................................................................................................... 16-108

ESC_overTemperature ..................................................................................................................................................... 16-110

ESCProc_softwareVersionMismatch ......................................................................................................................... 16-112

...................................................................................................................................................................................................................................
xxvi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

ESCBPEtherPort alarms

Overview .............................................................................................................................................................................. 16-114

ESCBPEtherPort_linkFailure ........................................................................................................................................ 16-115

ESCFAEtherPort alarms

Overview .............................................................................................................................................................................. 16-117

ESCFAEtherPort_linkFailure ........................................................................................................................................ 16-118

ESCProc alarms

Overview .............................................................................................................................................................................. 16-120

ESCProc_communicationFailure ................................................................................................................................ 16-121

ExtAlmBox alarms

Overview .............................................................................................................................................................................. 16-123

ExtAlmBox_communicationFailure .......................................................................................................................... 16-125

ExtAlmBox_externalAlarmPort1 ................................................................................................................................ 16-127

ExtAlmBox_externalAlarmPort10 ............................................................................................................................. 16-129

ExtAlmBox_externalAlarmPort11 .............................................................................................................................. 16-131

ExtAlmBox_externalAlarmPort12 ............................................................................................................................. 16-133

ExtAlmBox_externalAlarmPort13 ............................................................................................................................. 16-135

ExtAlmBox_externalAlarmPort14 ............................................................................................................................. 16-137

ExtAlmBox_externalAlarmPort15 ............................................................................................................................. 16-139

ExtAlmBox_externalAlarmPort16 ............................................................................................................................. 16-141

ExtAlmBox_externalAlarmPort17 ............................................................................................................................. 16-143

ExtAlmBox_externalAlarmPort18 ............................................................................................................................. 16-145

ExtAlmBox_externalAlarmPort19 ............................................................................................................................. 16-147

ExtAlmBox_externalAlarmPort2 ................................................................................................................................ 16-149

ExtAlmBox_externalAlarmPort20 ............................................................................................................................. 16-151

ExtAlmBox_externalAlarmPort21 ............................................................................................................................. 16-153

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxvii
Issue 1, August 2007 See notice on first page
Contents

ExtAlmBox_externalAlarmPort22 ............................................................................................................................. 16-155

ExtAlmBox_externalAlarmPort23 ............................................................................................................................. 16-157

ExtAlmBox_externalAlarmPort24 ............................................................................................................................. 16-159

ExtAlmBox_externalAlarmPort25 ............................................................................................................................. 16-161

ExtAlmBox_externalAlarmPort26 ............................................................................................................................. 16-163

ExtAlmBox_externalAlarmPort27 ............................................................................................................................. 16-165

ExtAlmBox_externalAlarmPort28 ............................................................................................................................. 16-167

ExtAlmBox_externalAlarmPort29 ............................................................................................................................. 16-169

ExtAlmBox_externalAlarmPort3 ................................................................................................................................ 16-171

ExtAlmBox_externalAlarmPort30 ............................................................................................................................. 16-173

ExtAlmBox_externalAlarmPort31 ............................................................................................................................. 16-175

ExtAlmBox_externalAlarmPort32 ............................................................................................................................. 16-177

ExtAlmBox_externalAlarmPort4 ................................................................................................................................ 16-179

ExtAlmBox_externalAlarmPort5 ................................................................................................................................ 16-181

ExtAlmBox_externalAlarmPort6 ................................................................................................................................ 16-183

ExtAlmBox_externalAlarmPort7 ................................................................................................................................ 16-185

ExtAlmBox_externalAlarmPort8 ................................................................................................................................ 16-187

ExtAlmBox_externalAlarmPort9 ................................................................................................................................ 16-189

FBPShelf alarms

Overview .............................................................................................................................................................................. 16-191

FBPShelf_overTemperature .......................................................................................................................................... 16-192

FBPShelf_overTemperatureSensor1 .......................................................................................................................... 16-194

FBPShelf_overTemperatureSensor2 .......................................................................................................................... 16-196

FBPShelf_overTemperatureSensor3 .......................................................................................................................... 16-198

FBPShelf_overTemperatureSensor4 .......................................................................................................................... 16-200

FBPShelf_overTemperatureSensor5 .......................................................................................................................... 16-202

FBPShelf_overTemperatureSensor6 .......................................................................................................................... 16-204


...................................................................................................................................................................................................................................
xxviii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

FBPShelf_overTemperatureSensor7 .......................................................................................................................... 16-206

FBPShelf_overTemperatureSensor8 .......................................................................................................................... 16-208

FanTray alarms

Overview .............................................................................................................................................................................. 16-210

FanTray_fan1Failure ........................................................................................................................................................ 16-211

FanTray_fan2Failure ........................................................................................................................................................ 16-213

FanTray_fan3Failure ........................................................................................................................................................ 16-215

FanTray_notInstalled ....................................................................................................................................................... 16-217

GICC alarms

Overview .............................................................................................................................................................................. 16-218

GICC_degradeGroupMemberFault ............................................................................................................................ 16-219

GICC_escalatingRecovery ............................................................................................................................................. 16-221

GICC_failureGroupMemberFault ............................................................................................................................... 16-223

GICC_lossOfPower .......................................................................................................................................................... 16-225

GICC_lossOfSanity .......................................................................................................................................................... 16-227

GICC_lostCommunication ............................................................................................................................................ 16-229

GICC_maintenanceMode ............................................................................................................................................... 16-231

GICC_notInstalled ............................................................................................................................................................ 16-232

GICC_overTemperature .................................................................................................................................................. 16-234

GICC_overTemperatureInFlow ................................................................................................................................... 16-236

GICC_overTemperatureOutFlow ................................................................................................................................ 16-238

GICCBPEtherPort alarms

Overview .............................................................................................................................................................................. 16-240

GICCBPEtherPort_communicationFailureESC1_2 ............................................................................................. 16-241

GICCBPEtherPort_communicationFailureESC1_21 .......................................................................................... 16-243

GICCBPEtherPort_communicationFailureESC2_2 ............................................................................................. 16-245

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxix
Issue 1, August 2007 See notice on first page
Contents

GICCBPEtherPort_communicationFailureESC2_21 .......................................................................................... 16-247

GICCBPEtherPort_linkFailure ..................................................................................................................................... 16-249

GICCBPEtherPort_restoreServiceFailure ................................................................................................................ 16-251

GICCFAEtherPort alarms

Overview .............................................................................................................................................................................. 16-253

GICCFAEtherPort_linkFailure ..................................................................................................................................... 16-254

GICCFAEtherPort_restoreServiceFailure ................................................................................................................ 16-256

GICCProc alarms

Overview .............................................................................................................................................................................. 16-258

GICCProc_allOpticalLinksFailed ............................................................................................................................... 16-259

GICCProc_communicationFailure ............................................................................................................................. 16-261

GICCProc_communicationFailureLRM ................................................................................................................... 16-263

GICCProc_configurationError ..................................................................................................................................... 16-265

GICCProc_cpuUsageOverload .................................................................................................................................... 16-266

GICCProc_criticalSoftwareFailure ............................................................................................................................. 16-267

GICCProc_heartbeatFailure .......................................................................................................................................... 16-269

GICCProc_memoryBlockError ................................................................................................................................... 16-271

GICCProc_memoryUsageOverload ........................................................................................................................... 16-273

GICCProc_resourceFailure ........................................................................................................................................... 16-274

GICCProc_restoreServiceFailure ................................................................................................................................ 16-276

GICCProc_softwareAssertError .................................................................................................................................. 16-278

GICCProc_softwareVersionMismatch ...................................................................................................................... 16-280

GICCProc_standbyMateDown ..................................................................................................................................... 16-282

GICCProc_vitalResourceFailure ................................................................................................................................. 16-284

GICCSTM1OC3Port alarms

Overview .............................................................................................................................................................................. 16-286

...................................................................................................................................................................................................................................
xxx Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

GICCSTM1OC3Port_linkFailure ............................................................................................................................... 16-287

GICCSTM1OC3Port_linkFailureAIS_L .................................................................................................................. 16-289

GICCSTM1OC3Port_linkFailureAIS_P .................................................................................................................. 16-291

GICCSTM1OC3Port_linkFailureLCD_P ................................................................................................................ 16-293

GICCSTM1OC3Port_linkFailureLOF ...................................................................................................................... 16-295

GICCSTM1OC3Port_linkFailureLOP_P ................................................................................................................. 16-297

GICCSTM1OC3Port_linkFailureLOS ...................................................................................................................... 16-299

GICCSTM1OC3Port_linkFailurePLM_P ................................................................................................................ 16-301

GICCSTM1OC3Port_linkFailureRDI_L ................................................................................................................. 16-303

GICCSTM1OC3Port_linkFailureRDI_P .................................................................................................................. 16-305

GICCSTM1OC3Port_restoreServiceFailure ........................................................................................................... 16-307

HSDPA alarms

Overview .............................................................................................................................................................................. 16-309

HSDPA_degraded ............................................................................................................................................................. 16-310

HSDPA_failed .................................................................................................................................................................... 16-312

HSDPA_hSDPAOCNSchannelSetupFailure ........................................................................................................... 16-314

HSDPA_notInstalled ........................................................................................................................................................ 16-316

IuB alarms

Overview .............................................................................................................................................................................. 16-318

IuB_cellReconfigTimeout .............................................................................................................................................. 16-319

IuB_cellSetupTimeout ..................................................................................................................................................... 16-321

IuB_channelReconfigFailure ........................................................................................................................................ 16-323

IuB_channelReconfigTimeout ...................................................................................................................................... 16-325

IuB_channelSetupFailure ............................................................................................................................................... 16-327

IuB_channelSetupTimeout ............................................................................................................................................ 16-329

IuB_highBER ..................................................................................................................................................................... 16-331

IuB_nBAP_Reset_Requ_CCP_Fail ........................................................................................................................... 16-333


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxxi
Issue 1, August 2007 See notice on first page
Contents

IuB_nBAP_Reset_Requ_Fail ....................................................................................................................................... 16-335

IuB_nodeBCommunicationLost .................................................................................................................................. 16-337

IuB_parameterFailure ...................................................................................................................................................... 16-340

IuB_resourceFailure ......................................................................................................................................................... 16-342

IuB_sAALUNI_RES_PROT_STA_DN ................................................................................................................... 16-344

IuB_sAALUNI_VCC_ST_DN .................................................................................................................................... 16-346

IuB_uNIStack_FAIL ........................................................................................................................................................ 16-348

IuCS alarms

Overview .............................................................................................................................................................................. 16-350

IuCS_coreNetwork_OOS_For_NonUE_Sig ........................................................................................................... 16-351

IuCS_rANAPResetFail ................................................................................................................................................... 16-353

IuCS_remoteSubsystemOutOfService ...................................................................................................................... 16-355

IuCS_sNE_Context_Cre_Fail_For_NonUE_Sig .................................................................................................. 16-357

IuPS alarms

Overview .............................................................................................................................................................................. 16-359

IuPS_coreNetwork_OOS_For_NonUE_Sig ........................................................................................................... 16-360

IuPS_gTP_U_Echo_Responses_Not_Received .................................................................................................... 16-362

IuPS_rANAPResetFail .................................................................................................................................................... 16-364

IuPS_remoteSubsystemOutOfService ....................................................................................................................... 16-366

IuPS_sNE_Context_Cre_Fail_For_NonUE_Sig ................................................................................................... 16-368

IuPSSubNet alarms

Overview .............................................................................................................................................................................. 16-370

IuPSSubNet_communicationFailure .......................................................................................................................... 16-371

IuR alarms

Overview .............................................................................................................................................................................. 16-373

IuR_pRNC_OOS_For_NonUE_Sig ........................................................................................................................... 16-374

...................................................................................................................................................................................................................................
xxxii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

IuR_remoteSubsystemOutOfService ......................................................................................................................... 16-376

IuR_sNE_Context_Cre_Fail_For_NonUE_Sig ..................................................................................................... 16-378

LCell alarms

Overview .............................................................................................................................................................................. 16-380

LCell_avail_Status_Degraded ...................................................................................................................................... 16-381

LCell_bCCHScheduleErr ............................................................................................................................................... 16-382

LCell_callPreemptionError ........................................................................................................................................... 16-384

LCell_callPreemptionFailure ........................................................................................................................................ 16-386

LCell_channelSetupFailure ........................................................................................................................................... 16-388

LCell_code_Allocation_Failure ................................................................................................................................... 16-390

LCell_code_Starvation .................................................................................................................................................... 16-392

LCell_common_Transport_Channel_Reconfiguration_Failure ....................................................................... 16-394

LCell_common_Transport_Channel_Reconfiguration_Timeout .................................................................... 16-396

LCell_common_Transport_Channel_Setup_Failure ............................................................................................ 16-398

LCell_common_Transport_Channel_Setup_Timeout ......................................................................................... 16-400

LCell_configurationError ............................................................................................................................................... 16-402

LCell_configurationErrorSCCPCH ............................................................................................................................ 16-404

LCell_nodeBUnavailable ............................................................................................................................................... 16-406

LCell_rRC_Connection_Establish_Failure ............................................................................................................. 16-408

LCell_reconfigFailure ..................................................................................................................................................... 16-410

LCell_reconfigTimeout ................................................................................................................................................... 16-412

LCell_setupFailure ........................................................................................................................................................... 16-414

LCell_setupTimeout ......................................................................................................................................................... 16-416

LCell_system_Information_Update_Failure ........................................................................................................... 16-418

LCell_tPUCellContextFailure ...................................................................................................................................... 16-420

LNodeB alarms

Overview .............................................................................................................................................................................. 16-421


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxxiii
Issue 1, August 2007 See notice on first page
Contents

LNodeB_cell_Deletion_No_Response ..................................................................................................................... 16-422

LNodeB_cre_Control_End_Pt_Fail ........................................................................................................................... 16-424

LNodeB_download_Logical_Cell_Information_To_RNC_Failed ................................................................. 16-425

LRNC alarms

Overview .............................................................................................................................................................................. 16-427

LRNC_alarmDefFileCorrupt ........................................................................................................................................ 16-429

LRNC_alarmDefFileMissing ........................................................................................................................................ 16-431

LRNC_cLIScriptFailed ................................................................................................................................................... 16-433

LRNC_ciccGiccConfigFileMissing ........................................................................................................................... 16-435

LRNC_clockSourceFailure ........................................................................................................................................... 16-437

LRNC_configurationError ............................................................................................................................................. 16-438

LRNC_coreFileGenerated ............................................................................................................................................. 16-440

LRNC_dBReplicationAuditFailure ............................................................................................................................ 16-442

LRNC_dGPSCorrFailure ............................................................................................................................................... 16-445

LRNC_dataAuditFailure ................................................................................................................................................ 16-447

LRNC_degradeGroupMemberFault ........................................................................................................................... 16-449

LRNC_eventFloodConditionDetected ...................................................................................................................... 16-451

LRNC_failureGroupMemberFault ............................................................................................................................. 16-453

LRNC_ftProcessError ..................................................................................................................................................... 16-454

LRNC_general_Handling_Error_Indication ........................................................................................................... 16-457

LRNC_hostProcessCommunicationFailure ............................................................................................................. 16-459

LRNC_hostProcessEnlistTimeout .............................................................................................................................. 16-461

LRNC_hostProcessFailure ............................................................................................................................................. 16-463

LRNC_hostProcessRestartFailure ............................................................................................................................... 16-464

LRNC_hostProcessRestartSuspended ....................................................................................................................... 16-466

LRNC_hostProcessTerminationFailure .................................................................................................................... 16-468

LRNC_iCNOAPVCMeshErr ........................................................................................................................................ 16-470


...................................................................................................................................................................................................................................
xxxiv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

LRNC_iNITrunLevelTimeout ...................................................................................................................................... 16-472

LRNC_iNITterminatingTimeout ................................................................................................................................. 16-474

LRNC_internal_Clock_Source_Disconnected ....................................................................................................... 16-476

LRNC_log100PercentFull ............................................................................................................................................. 16-477

LRNC_log80PercentFull ................................................................................................................................................ 16-479

LRNC_miscellaneous-Cause ........................................................................................................................................ 16-481

LRNC_oamStateControlFailure .................................................................................................................................. 16-483

LRNC_perfMgr_DNMAP_INIT ................................................................................................................................. 16-485

LRNC_pmArchiveInitFailure ....................................................................................................................................... 16-487

LRNC_pmCTDBImageFailure .................................................................................................................................... 16-489

LRNC_pmCTDBInitFailure .......................................................................................................................................... 16-491

LRNC_primary_Clock_Source_Disconnected ...................................................................................................... 16-493

LRNC_sMLC_UDP_Port_Fail .................................................................................................................................... 16-495

LRNC_sRS_NAV_Data_Ind ......................................................................................................................................... 16-496

LRNC_secondSRSTCPEstLinkFailure ..................................................................................................................... 16-498

LRNC_suActivationFailure ........................................................................................................................................... 16-500

LRNC_suApplyFailure ................................................................................................................................................... 16-503

LRNC_suBackoutFailure ............................................................................................................................................... 16-506

LRNC_suCommitFailure ............................................................................................................................................... 16-510

LRNC_suDeApplyFailure ............................................................................................................................................. 16-512

LRNC_suDeleteFailure ................................................................................................................................................... 16-515

LRNC_suDownloadFailure ........................................................................................................................................... 16-517

LRNC_suFallbackFailure ............................................................................................................................................... 16-520

LRNC_suICCPartialUpdateFailure ............................................................................................................................ 16-523

LRNC_suInfoSyncFailure ............................................................................................................................................. 16-526

LRNC_suInstallFailure ................................................................................................................................................... 16-529

LRNC_suStatePanicFailure ........................................................................................................................................... 16-531


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxxv
Issue 1, August 2007 See notice on first page
Contents

LRNC_ueCompressedModeGapOverlap ................................................................................................................. 16-533

LRNC_utranCompressedModeGapOverlap ............................................................................................................ 16-535

OCNS alarms

Overview .............................................................................................................................................................................. 16-537

OCNS_chDelRxLock ...................................................................................................................................................... 16-538

OCNS_channelFailure ..................................................................................................................................................... 16-540

OCNS_channelReconfigFailure .................................................................................................................................. 16-542

OCNS_channelReestablished ....................................................................................................................................... 16-544

OCNS_channelSetupFailure ......................................................................................................................................... 16-546

OCNS_resourcesUnavailable ....................................................................................................................................... 16-548

OCNSHSDPA alarms

Overview .............................................................................................................................................................................. 16-550

OCNSHSDPA_failureIndicationFromNodeB ........................................................................................................ 16-551

OCNSHSDPA_setupFailed ........................................................................................................................................... 16-553

PG alarms

Overview .............................................................................................................................................................................. 16-555

PG_apsCriticalLineFailure ............................................................................................................................................ 16-556

PG_apsCriticalProcessorFailure .................................................................................................................................. 16-558

PG_apsMajorLineFailure ............................................................................................................................................... 16-560

PG_apsMajorProcessorFailure ..................................................................................................................................... 16-562

PG_apsMinorLineFailure ............................................................................................................................................... 16-564

PG_apsMinorProcessorFailure ..................................................................................................................................... 16-566

PRACH alarms

Overview .............................................................................................................................................................................. 16-568

PRACH_op_State_Disabled ......................................................................................................................................... 16-569

...................................................................................................................................................................................................................................
xxxvi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

PSU alarms

Overview .............................................................................................................................................................................. 16-571

PSU_equipmentFailure ................................................................................................................................................... 16-572

PSU_overTemperature .................................................................................................................................................... 16-574

RF trace alarms

Overview .............................................................................................................................................................................. 16-576

RFTrace_ueMeasurementsUnavailable ..................................................................................................................... 16-577

SB alarms

Overview .............................................................................................................................................................................. 16-579

SB_bscSwFailOutage_CNIWMCapsule1 ................................................................................................................ 16-580

SB_bscSwFailOutage_CellServerCapsule1 ............................................................................................................ 16-582

SB_bscSwFailOutage_CellServerCapsule10 .......................................................................................................... 16-584

SB_bscSwFailOutage_CellServerCapsule2 ............................................................................................................ 16-586

SB_bscSwFailOutage_CellServerCapsule3 ............................................................................................................ 16-588

SB_bscSwFailOutage_CellServerCapsule4 ............................................................................................................ 16-590

SB_bscSwFailOutage_CellServerCapsule5 ............................................................................................................ 16-592

SB_bscSwFailOutage_CellServerCapsule6 ............................................................................................................ 16-594

SB_bscSwFailOutage_CellServerCapsule7 ............................................................................................................ 16-596

SB_bscSwFailOutage_CellServerCapsule8 ............................................................................................................ 16-598

SB_bscSwFailOutage_CellServerCapsule9 ............................................................................................................ 16-600

SB_bscSwFailOutage_PeerRNCIWMCapsule1 .................................................................................................... 16-602

SB_bscSwFailOutage_RNSServerCapsule1 ........................................................................................................... 16-604

SB_degradeGroupMemberFault .................................................................................................................................. 16-606

SB_failureGroupMemberFault ..................................................................................................................................... 16-608

SB_lossOfPower ................................................................................................................................................................ 16-610

SB_lossOfSanity ................................................................................................................................................................ 16-612

SB_lostCommunication .................................................................................................................................................. 16-614


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxxvii
Issue 1, August 2007 See notice on first page
Contents

SB_maintenanceMode ..................................................................................................................................................... 16-616

SB_notInstalled .................................................................................................................................................................. 16-617

SB_overTemperature ....................................................................................................................................................... 16-619

SBBPEtherPort alarms

Overview .............................................................................................................................................................................. 16-621

SBBPEtherPort_linkFailure .......................................................................................................................................... 16-622

SBClan alarms

Overview .............................................................................................................................................................................. 16-623

SBClan_linkFail ................................................................................................................................................................ 16-624

SBProc alarms

Overview .............................................................................................................................................................................. 16-625

SBProc_acCommunicationFailure .............................................................................................................................. 16-627

SBProc_componentMissing .......................................................................................................................................... 16-628

SBProc_cpuUsageOverload .......................................................................................................................................... 16-629

SBProc_diskReadTimeExceeded ................................................................................................................................ 16-630

SBProc_fLXEV_CLAN_PARENT_FAIL ............................................................................................................... 16-632

SBProc_fLXEV_NODE_FAILING ........................................................................................................................... 16-633

SBProc_fLXEV_NODE_NOTACTIVE ................................................................................................................... 16-635

SBProc_fLXEV_SMON_NOHBEAT ....................................................................................................................... 16-637

SBProc_filesystem01Full ............................................................................................................................................... 16-639

SBProc_filesystem02Full ............................................................................................................................................... 16-640

SBProc_filesystem03Full ............................................................................................................................................... 16-641

SBProc_filesystem04Full ............................................................................................................................................... 16-642

SBProc_filesystem05Full ............................................................................................................................................... 16-643

SBProc_filesystem06Full ............................................................................................................................................... 16-644

SBProc_filesystem07Full ............................................................................................................................................... 16-645

...................................................................................................................................................................................................................................
xxxviii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

SBProc_filesystem08Full ............................................................................................................................................... 16-646

SBProc_filesystem09Full ............................................................................................................................................... 16-647

SBProc_filesystem10Full ............................................................................................................................................... 16-648

SBProc_filesystem11Full ............................................................................................................................................... 16-649

SBProc_filesystem12Full ............................................................................................................................................... 16-650

SBProc_filesystem13Full ............................................................................................................................................... 16-651

SBProc_filesystem14Full ............................................................................................................................................... 16-652

SBProc_filesystem15Full ............................................................................................................................................... 16-653

SBProc_filesystem16Full ............................................................................................................................................... 16-654

SBProc_lossOfClockSourceSync ................................................................................................................................ 16-655

SBProc_memoryUsageOverload ................................................................................................................................. 16-657

SBProc_nodeFailure ........................................................................................................................................................ 16-659

SBProc_overTemperature .............................................................................................................................................. 16-661

SBProc_processFailure ................................................................................................................................................... 16-663

SBProc_processFailureApplication ............................................................................................................................ 16-665

SBProc_rootLoginFailure .............................................................................................................................................. 16-668

SBProc_sULoginFailure ................................................................................................................................................. 16-669

SBProc_shutdownTempReached ................................................................................................................................. 16-670

SBProc_temperatureOffLimits ..................................................................................................................................... 16-672

SBProc_userLoginFailure .............................................................................................................................................. 16-674

SBProc_virtualClusterFailure ....................................................................................................................................... 16-675

SBProc_virtualClusterVirtualMachineFailure ........................................................................................................ 16-676

SCCPCHFach alarms

Overview .............................................................................................................................................................................. 16-678

SCCPCHFach_op_State_Disabled ............................................................................................................................. 16-679

SCCPCHPch alarms

Overview .............................................................................................................................................................................. 16-681


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xxxix
Issue 1, August 2007 See notice on first page
Contents

SCCPCHPch_op_State_Disabled ............................................................................................................................... 16-682

SMLC alarms

Overview .............................................................................................................................................................................. 16-684

SMLC_dGPSCorrectionFailure ................................................................................................................................... 16-685

SMLC_primarySRSIpConnectionFailure ................................................................................................................ 16-687

SMLC_primarySRSLinkFailure .................................................................................................................................. 16-689

SMLC_sRS-Both-IP-Fail ............................................................................................................................................... 16-691

SMLC_sRS_SV_Ind ........................................................................................................................................................ 16-693

SMLC_secondarySRSIpConnectionFailure ............................................................................................................ 16-695

SMLC_secondarySRSLinkFailure ............................................................................................................................. 16-697

SS7Link alarms

Overview .............................................................................................................................................................................. 16-699

SS7Link_mtp3LinkDown .............................................................................................................................................. 16-700

SS7Link_mtp3LinkRemotelyBlocked ....................................................................................................................... 16-702

SS7Link_qsaalLinkCongested ..................................................................................................................................... 16-704

SS7LinkSet alarms

Overview .............................................................................................................................................................................. 16-706

SS7LinkSet_congestionTowardsRemoteMTP3 ..................................................................................................... 16-707

SS7LinkSet_remoteMTP3Unreachable .................................................................................................................... 16-709

SS7LinkSet_remoteMTP3UserUnavailable ............................................................................................................ 16-711

SS7Stack alarms

Overview .............................................................................................................................................................................. 16-712

SS7Stack_nniStackFailure ............................................................................................................................................. 16-713

17 Corrective maintenance - fault localization

Overview ................................................................................................................................................................................... 17-1

...................................................................................................................................................................................................................................
xl Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Diagnose hardware

Overview ................................................................................................................................................................................... 17-3

Diagnose RNC hardware .................................................................................................................................................... 17-4

Diagnose Node B hardware ............................................................................................................................................... 17-7

Ping network elements

Overview ................................................................................................................................................................................. 17-10

Ping to check interfaces to OMC server ................................................................................................................... 17-11

Ping a Node B from the RNC ....................................................................................................................................... 17-13

Retrieve alarm status

Overview ................................................................................................................................................................................. 17-15

Retrieve alarms - one object ........................................................................................................................................... 17-16

Retrieve alarms - UTRAN ............................................................................................................................................... 17-18

Retrieve alarms - RNC hardware ................................................................................................................................. 17-20

Retrieve alarms - Node B hardware ............................................................................................................................ 17-22

Retrieve alarms - Iu-ps link ............................................................................................................................................ 17-24

Retrieve alarms - Iu-cs link ............................................................................................................................................ 17-27

Retrieve alarms - Iub link ................................................................................................................................................ 17-30

Retrieve alarms - Iur link ................................................................................................................................................ 17-35

Retrieve OMC log files

Overview ................................................................................................................................................................................. 17-38

Retrieve OMC log files .................................................................................................................................................... 17-39

Retrieve RNC and Node B log files

Overview ................................................................................................................................................................................. 17-41

Retrieve RNC log files ..................................................................................................................................................... 17-42

Retrieve Node B log files ................................................................................................................................................ 17-46

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xli
Issue 1, August 2007 See notice on first page
Contents

18 Corrective maintenance - fault correction

Overview ................................................................................................................................................................................... 18-1

UTRAN Fault correction process

Overview ................................................................................................................................................................................... 18-2

Fault correction process ...................................................................................................................................................... 18-3

Recover failing RNS network elements

Overview ................................................................................................................................................................................... 18-6

Recover a failing RNC ........................................................................................................................................................ 18-7

Recover a failing Node B ................................................................................................................................................ 18-11

Reset objects

Overview ................................................................................................................................................................................. 18-15

Reset RNC objects .............................................................................................................................................................. 18-16

Reset Node B objects ........................................................................................................................................................ 18-21

19 Corrective maintenance - test correction

Overview ................................................................................................................................................................................... 19-1

Test Cell object ....................................................................................................................................................................... 19-2

20 Corrective maintenance - trouble administration

Overview ................................................................................................................................................................................... 20-1

Reports and logs ..................................................................................................................................................................... 20-2

Part V: Performance Management

21 UTRAN performance management

Overview ................................................................................................................................................................................... 21-1

UTRAN PM architecture .................................................................................................................................................... 21-2

Concept and terminology ................................................................................................................................................... 21-4

Performance management functionality ....................................................................................................................... 21-6

Example of a PM measurement ....................................................................................................................................... 21-7


...................................................................................................................................................................................................................................
xlii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Suspect PM measurements ................................................................................................................................................ 21-8

22 PM data collection

Overview ................................................................................................................................................................................... 22-1

Manage PM data collection ............................................................................................................................................... 22-2

Activate PM data collection on the RNC .................................................................................................................. 22-4

Activate PM data collection on the Node B .............................................................................................................. 22-6

Download PM data to the OMC ..................................................................................................................................... 22-8

Deactivate PM data collection on the RNC ........................................................................................................... 22-10

Deactivate PM data collection on the Node B ....................................................................................................... 22-12

View PM data Files .......................................................................................................................................................... 22-14

Part VI: Configuration Management

23 Initial system configuration

Overview ................................................................................................................................................................................... 23-1

Preliminary network data provisioning ......................................................................................................................... 23-2

24 Manage system configuration using GUI

Overview ................................................................................................................................................................................... 24-1

Add objects

Overview ................................................................................................................................................................................... 24-4

Add SNM objects - reference table ............................................................................................................................... 24-5

Add RNC objects - reference table ................................................................................................................................ 24-6

Add Node B objects - reference table ........................................................................................................................ 24-10

Add an individual object .................................................................................................................................................. 24-13

Create a new Link Profile ............................................................................................................................................... 24-15

Add a User Network Interface (UNI) ......................................................................................................................... 24-16

Add an SGSN ....................................................................................................................................................................... 24-17

Add an MSC ......................................................................................................................................................................... 24-18

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xliii
Issue 1, August 2007 See notice on first page
Contents

Add an external RNC ........................................................................................................................................................ 24-19

Add a UTRAN ..................................................................................................................................................................... 24-20

Add an RNS .......................................................................................................................................................................... 24-23

Add an RNC .......................................................................................................................................................................... 24-24

Add an Iur link ..................................................................................................................................................................... 24-27

Add a Node B ....................................................................................................................................................................... 24-29

Add a cell ............................................................................................................................................................................... 24-31

Add a neighbor cell relation ........................................................................................................................................... 24-33

Modify objects

Overview ................................................................................................................................................................................. 24-36

Modify SNM objects - reference table ....................................................................................................................... 24-37

Modify RNC objects - reference table ....................................................................................................................... 24-38

Modify Node B objects - reference table .................................................................................................................. 24-41

Modify attributes related to cell (re)selection ......................................................................................................... 24-43

Modify attributes related to paging ............................................................................................................................. 24-45

Modify attributes related to cell access ..................................................................................................................... 24-47

Modify attributes related to power control ............................................................................................................... 24-49

Modify attributes related to handover ........................................................................................................................ 24-51

Modify RNC related attributes ...................................................................................................................................... 24-53

Modify Node B related attributes ................................................................................................................................. 24-54

Modify cell related attributes ......................................................................................................................................... 24-55

Modify neighbor cell relations ....................................................................................................................................... 24-57

Modify object attributes ................................................................................................................................................... 24-59

Modify externalAlarms attribute ................................................................................................................................... 24-61

Remove objects

Overview ................................................................................................................................................................................. 24-64

Remove SNM objects - reference table ..................................................................................................................... 24-65


...................................................................................................................................................................................................................................
xliv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Remove RNC objects - reference table ..................................................................................................................... 24-66

Remove Node B objects - reference table ................................................................................................................ 24-69

Remove neighbor cell relations ..................................................................................................................................... 24-71

Remove a cell ....................................................................................................................................................................... 24-73

Remove an Iur link ............................................................................................................................................................. 24-75

Remove an RNC .................................................................................................................................................................. 24-77

Remove a Node B ............................................................................................................................................................... 24-78

Remove an SGSN ............................................................................................................................................................... 24-80

Remove an MSC ................................................................................................................................................................. 24-81

Remove an external RNC ................................................................................................................................................ 24-82

Remove an RNS .................................................................................................................................................................. 24-83

Remove individual object ................................................................................................................................................ 24-84

Modify administrative state

Overview ................................................................................................................................................................................. 24-86

Lock Node B objects ......................................................................................................................................................... 24-87

Lock RNC objects ............................................................................................................................................................... 24-90

Unlock Node B objects ..................................................................................................................................................... 24-94

Unlock RNC objects .......................................................................................................................................................... 24-96

Shut down Node B objects ............................................................................................................................................. 24-98

Shut down RNC objects ................................................................................................................................................ 24-100

Retrieve cell related attributes

Overview .............................................................................................................................................................................. 24-102

Retrieve attributes related to cell (re)selection ..................................................................................................... 24-103

Retrieve attributes related to paging ......................................................................................................................... 24-106

Retrieve attributes related to cell access ................................................................................................................. 24-110

Retrieve attributes related to power control ........................................................................................................... 24-113

Retrieve attributes related to handover .................................................................................................................... 24-117


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xlv
Issue 1, August 2007 See notice on first page
Contents

Retrieve functional status

Overview .............................................................................................................................................................................. 24-121

Retrieve functional status — one object ................................................................................................................. 24-122

Retrieve functional status — RNC hardware ........................................................................................................ 24-123

Retrieve functional status — Node B hardware .................................................................................................. 24-125

Retrieve functional status — Iu-ps link .................................................................................................................. 24-127

Retrieve functional status — Iu-cs link ................................................................................................................... 24-129

Retrieve functional status — Iub link ...................................................................................................................... 24-131

Retrieve functional status — Iur link ....................................................................................................................... 24-136

Retrieve hardware inventory data

Overview .............................................................................................................................................................................. 24-138

Perform inventory audit on an object ....................................................................................................................... 24-139

Perform Consistency Audit

Overview .............................................................................................................................................................................. 24-142

Consistency audit .............................................................................................................................................................. 24-143

Consistency Audit process ............................................................................................................................................ 24-145

Consistency Audit Reports ............................................................................................................................................ 24-147

Performing Consistency Audit ..................................................................................................................................... 24-149

Viewing the Consistency Audit Reports .................................................................................................................. 24-152

25 Manage system configuration using CLI

Overview ................................................................................................................................................................................... 25-1

Add objects

Overview ................................................................................................................................................................................... 25-4

Add SNM objects - reference table ............................................................................................................................... 25-5

Add RNC objects - reference table ................................................................................................................................ 25-7

Add Node B objects - reference table ........................................................................................................................ 25-11

...................................................................................................................................................................................................................................
xlvi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Add an individual object .................................................................................................................................................. 25-14

Create a new Link Profile ............................................................................................................................................... 25-16

Add a User Network Interface (UNI) ......................................................................................................................... 25-19

Add an SGSN ....................................................................................................................................................................... 25-21

Add an MSC ......................................................................................................................................................................... 25-23

Add an external RNC ........................................................................................................................................................ 25-25

Add a UTRAN ..................................................................................................................................................................... 25-27

Add an RNS .......................................................................................................................................................................... 25-30

Add an RNC .......................................................................................................................................................................... 25-31

Add an Iur link ..................................................................................................................................................................... 25-36

Add a Node B ....................................................................................................................................................................... 25-39

Add a cell ............................................................................................................................................................................... 25-43

Add a neighbor cell relation ........................................................................................................................................... 25-46

Modify objects

Overview ................................................................................................................................................................................. 25-53

Modify SNM objects - reference table ....................................................................................................................... 25-54

Modify RNC objects - reference table ....................................................................................................................... 25-56

Modify Node B objects - reference table .................................................................................................................. 25-59

Modify attributes related to cell access ..................................................................................................................... 25-62

Modify attributes related to cell (re)selection ......................................................................................................... 25-64

Modify attributes related to handover ........................................................................................................................ 25-66

Modify attributes related to paging ............................................................................................................................. 25-69

Modify attributes related to power control ............................................................................................................... 25-72

Modify RNC related attributes ...................................................................................................................................... 25-75

Modify Node B related attributes ................................................................................................................................. 25-77

Modify cell related attributes ......................................................................................................................................... 25-79

Modify neighbor cell relations ....................................................................................................................................... 25-82


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xlvii
Issue 1, August 2007 See notice on first page
Contents

Modify object attributes ................................................................................................................................................... 25-85

Modify externalAlarms attribute ................................................................................................................................... 25-87

Remove objects

Overview ................................................................................................................................................................................. 25-89

Remove SNM objects - reference table ..................................................................................................................... 25-90

Remove RNC objects - reference table ..................................................................................................................... 25-93

Remove Node B objects - reference table ................................................................................................................ 25-97

Remove an Iur link .......................................................................................................................................................... 25-100

Remove an RNC ............................................................................................................................................................... 25-103

Remove neighbor cell relations .................................................................................................................................. 25-107

Remove a cell ..................................................................................................................................................................... 25-112

Remove a Node B ............................................................................................................................................................ 25-115

Remove an SGSN ............................................................................................................................................................. 25-118

Remove an MSC ............................................................................................................................................................... 25-120

Remove an external RNC ............................................................................................................................................. 25-122

Remove an RNS ................................................................................................................................................................ 25-124

Remove individual object .............................................................................................................................................. 25-126

Modify administrative state

Overview .............................................................................................................................................................................. 25-127

Lock Node B objects ....................................................................................................................................................... 25-128

Lock RNC objects ............................................................................................................................................................ 25-131

Unlock Node B objects .................................................................................................................................................. 25-135

Unlock RNC objects ........................................................................................................................................................ 25-137

Shut down Node B objects ........................................................................................................................................... 25-139

Shut down RNC objects ................................................................................................................................................ 25-141

...................................................................................................................................................................................................................................
xlviii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Perform Consistency Audit

Overview .............................................................................................................................................................................. 25-143

Perform Consistency Audit ........................................................................................................................................... 25-144

Viewing the Consistency Audit Reports .................................................................................................................. 25-146

Rehome Node B

Overview .............................................................................................................................................................................. 25-147

Rehome Node B overview ............................................................................................................................................ 25-148

Rehome a Node B - online mode .............................................................................................................................. 25-150

Rehome a Node B - offline mode ............................................................................................................................. 25-156

Input parameters text file ............................................................................................................................................... 25-162

Input parameters validation .......................................................................................................................................... 25-165

Rehome Node B CLI logs ............................................................................................................................................ 25-171

Check pre-requisites and generate bulk export files .......................................................................................... 25-173

Generate XML files and CLI scripts ........................................................................................................................ 25-176

De-provision Node B ...................................................................................................................................................... 25-178

Re-provision Node B ....................................................................................................................................................... 25-184

Rehome Node B post-requisites ................................................................................................................................. 25-190

26 Manage software

Overview ................................................................................................................................................................................... 26-1

Backup data

Overview ................................................................................................................................................................................... 26-3

Backup RNC ............................................................................................................................................................................ 26-4

Backup Node B ...................................................................................................................................................................... 26-6

Restore backup data

Overview ................................................................................................................................................................................... 26-8

Restore RNC ............................................................................................................................................................................ 26-9

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary xlix
Issue 1, August 2007 See notice on first page
Contents

Restore Node B .................................................................................................................................................................... 26-11

Software upgrade - RNS

Overview ................................................................................................................................................................................. 26-13

RNS software upgrade process ...................................................................................................................................... 26-14

Software upgrade - RNC

Overview ................................................................................................................................................................................. 26-18

RNC software upgrade procedure ................................................................................................................................ 26-19

Copy RNC software to the OMC ................................................................................................................................. 26-21

Download software to an RNC ..................................................................................................................................... 26-23

Install software on an RNC ............................................................................................................................................ 26-26

Apply Software Patch on an RNC ............................................................................................................................... 26-28

Activate software on an RNC ........................................................................................................................................ 26-30

Commit software on an RNC ........................................................................................................................................ 26-32

Delete an RNC software version .................................................................................................................................. 26-34

De-Apply Software Patch on an RNC ....................................................................................................................... 26-36

Abort an RNC software upgrade operation .............................................................................................................. 26-38

RNC software activation failure process ................................................................................................................... 26-40

Backout to the previous RNC software .................................................................................................................... 26-44

Fallback to the committed RNC software ................................................................................................................ 26-46

Software upgrade - Node B

Overview ................................................................................................................................................................................. 26-48

Node B software upgrade process ................................................................................................................................ 26-49

Copy Node B software to the OMC ........................................................................................................................... 26-51

Download software to a Node B .................................................................................................................................. 26-53

Activate software on a Node B ................................................................................................................................... 26-55

Abort a Node B software download operation ....................................................................................................... 26-57

...................................................................................................................................................................................................................................
l Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Node B software activation failure process ............................................................................................................. 26-58

Fallback to previous Node B software ....................................................................................................................... 26-61

27 Manage services

Overview ................................................................................................................................................................................... 27-1

OCNS service

Overview ................................................................................................................................................................................... 27-2

Manage the OCNS service ................................................................................................................................................ 27-3

Activate the OCNS service ................................................................................................................................................ 27-4

Deactivate the OCNS service ........................................................................................................................................... 27-6

RF trace service

Overview ................................................................................................................................................................................... 27-7

Manage the RF trace service ............................................................................................................................................ 27-8

Invoke the RFtrace object ................................................................................................................................................ 27-10

Start the RF trace service ................................................................................................................................................ 27-12

Stop the RF trace service ................................................................................................................................................. 27-14

Upload RF trace file to the OMC ................................................................................................................................ 27-15

HSDPA-OCNS service

Overview ................................................................................................................................................................................. 27-17

Manage the HSDPA-OCNS service ............................................................................................................................. 27-18

Activate the HSDPA-OCNS service ............................................................................................................................ 27-19

Deactivate the HSDPA-OCNS service ....................................................................................................................... 27-21

Part VII: Accounting Management

28 Accounting in the UMTS network

Overview ................................................................................................................................................................................... 28-1

Networks elements performing accounting ................................................................................................................. 28-2

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary li
Issue 1, August 2007 See notice on first page
Contents

Part VIII: Security Management

29 Managing Secure Shell and IPSec connections

Overview ................................................................................................................................................................................... 29-1

Secure Shell overview ......................................................................................................................................................... 29-2

Internet Protocol Security overview ............................................................................................................................... 29-4

IPSec and SSH configuration tasks ................................................................................................................................ 29-6

SSH periodic tasks .............................................................................................................................................................. 29-10

SSH troubleshooting tasks ............................................................................................................................................... 29-11

IPSec periodic tasks ........................................................................................................................................................... 29-13

30 Managing Node B user accounts

Overview ................................................................................................................................................................................... 30-1

Change Lucent User Password ........................................................................................................................................ 30-2

Synchronize Lucent User Password ............................................................................................................................... 30-3

Manage Node B Accounts ................................................................................................................................................. 30-4

Synchronize Node B Accounts ........................................................................................................................................ 30-6

A Wizard descriptions

Create wizards

Overview ..................................................................................................................................................................................... A-1

Add DAHORelation wizard ................................................................................................................................................ A-4

Add FDDExtCell on Peer RNC wizard ......................................................................................................................... A-8

Add ExtUtranRelation wizard ......................................................................................................................................... A-11

Add GSMRelation wizard ................................................................................................................................................. A-17

Add IMAGroup wizard ...................................................................................................................................................... A-22

Add IsDahoNQB Relation wizard ................................................................................................................................. A-24

Add Multiple UTRAN Relation wizard ...................................................................................................................... A-28

Add Multiple GSM Relation wizard ............................................................................................................................ A-34

...................................................................................................................................................................................................................................
lii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Add NeighborRelation wizard ......................................................................................................................................... A-39

AssociatePort wizard ........................................................................................................................................................... A-45

Associate E1T1Port to IMAGroup wizard ................................................................................................................. A-48

Create ATMQOS wizard .................................................................................................................................................... A-50

Create Cell wizard ................................................................................................................................................................ A-54

Create CPC wizard ............................................................................................................................................................... A-67

Create CTU wizard .............................................................................................................................................................. A-69

Create CPRIPort wizard ..................................................................................................................................................... A-71

Create E1T1Port wizard ..................................................................................................................................................... A-73

Create E3T3Port wizard ..................................................................................................................................................... A-75

Create External Gsm Cell wizard .................................................................................................................................. A-77

Create External Iur link wizard ...................................................................................................................................... A-80

Create External NE wizard ............................................................................................................................................... A-87

Create External Utran Cell wizard ................................................................................................................................ A-91

Create ExtRxAmp wizard ................................................................................................................................................. A-96

Create Filter wizard ............................................................................................................................................................. A-98

Create IOU wizard ............................................................................................................................................................. A-100

Create Itf-B link wizard .................................................................................................................................................. A-102

Create Itf-r link wizard .................................................................................................................................................... A-105

Create IuB link wizard ..................................................................................................................................................... A-108

Create IuCS link wizard .................................................................................................................................................. A-112

Create IuPS link wizard .................................................................................................................................................. A-120

Create IuPSSubnet wizard .............................................................................................................................................. A-127

Create Internal Iur link wizard ..................................................................................................................................... A-129

Create Node B wizard ...................................................................................................................................................... A-135

Create STM1OC3Port wizard ....................................................................................................................................... A-142

Create OCNS wizard ........................................................................................................................................................ A-144


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary liii
Issue 1, August 2007 See notice on first page
Contents

Create OCNSHSDPA wizard ......................................................................................................................................... A-147

Create OM wizard ............................................................................................................................................................. A-150

Create QOS wizard ........................................................................................................................................................... A-152

Create Radio wizard .......................................................................................................................................................... A-154

Create RFHead wizard ..................................................................................................................................................... A-156

Create RNC wizard ........................................................................................................................................................... A-158

Create RNS wizard ............................................................................................................................................................ A-163

Create RxAmp wizard ...................................................................................................................................................... A-165

Create SS7 Link wizard .................................................................................................................................................. A-167

Create SS7LinkSet wizard .............................................................................................................................................. A-170

Create TDU wizard ........................................................................................................................................................... A-172

Create TxAmp wizard ...................................................................................................................................................... A-174

Create UCU wizard ........................................................................................................................................................... A-176

Create Uni wizard .............................................................................................................................................................. A-178

Create URC wizard ........................................................................................................................................................... A-181

Grow Node B wizard ....................................................................................................................................................... A-183

Modify wizards

Overview ................................................................................................................................................................................ A-186

Modify Cell wizard ........................................................................................................................................................... A-187

Modify External UTRAN Relation wizard ............................................................................................................. A-192

Modify GSMRelation wizard ........................................................................................................................................ A-195

Modify NeighbourRelation wizard ............................................................................................................................. A-197

Modify Node B wizard .................................................................................................................................................... A-200

Modify RNC wizard ......................................................................................................................................................... A-203

Remove wizards

Overview ................................................................................................................................................................................ A-205

Degrow Node B wizard ................................................................................................................................................... A-207


...................................................................................................................................................................................................................................
liv Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Contents

Delete DahoRelation wizard .......................................................................................................................................... A-209

Delete FddExtCell on Peer RNC(s) wizard ............................................................................................................ A-212

Delete External IuR link wizard .................................................................................................................................. A-215

Delete ExtUtranRelation wizard .................................................................................................................................. A-217

Delete Neighbour Relation wizard .............................................................................................................................. A-220

Delete Multiple Neighbor Relations wizard ............................................................................................................ A-223

Delete GsmRelation wizard ........................................................................................................................................... A-226

Delete IMAGroup wizard ............................................................................................................................................... A-229

Delete IsDahoNQB Relation wizard .......................................................................................................................... A-231

Delete ItfB link wizard .................................................................................................................................................... A-234

Delete ItfR link wizard .................................................................................................................................................... A-236

Delete IuB link wizard ..................................................................................................................................................... A-238

Delete IuCS link wizard .................................................................................................................................................. A-240

Delete IuPS link wizard .................................................................................................................................................. A-242

Delete IuR link wizard ..................................................................................................................................................... A-244

Delete Node B wizard ...................................................................................................................................................... A-246

Delete RNC wizard ........................................................................................................................................................... A-248

Delete RNS wizard ............................................................................................................................................................ A-250

Delete UtranCell wizard .................................................................................................................................................. A-251

UnAssociatePort wizard .................................................................................................................................................. A-254

Unassociate E1T1Port from IMAGroup wizard .................................................................................................... A-256

B Retrieve SNM IuBLink DN

Overview ..................................................................................................................................................................................... B-1

SNM IuBLink DN .................................................................................................................................................................. B-2

C Product conformance statements

Overview ..................................................................................................................................................................................... C-1

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary lv
Issue 1, August 2007 See notice on first page
Contents

FCC conformance statements ............................................................................................................................................. C-2

UL and UL Canada conformance statements .............................................................................................................. C-4

Eco-environmental statements ............................................................................................................................................ C-5

Glossary

Index

...................................................................................................................................................................................................................................
lvi Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
About this information product
About this information product

Purpose
The purpose of this information product is to:
• Present an overview of how Operation, Administration, Maintenance and
Provisioning is performed on the UTRAN
• Present an overview of the hardware in the UTRAN
• Describe the Object Information Model that is used to represent the UTRAN
• Provide the Operation, Administration, Maintenance and Provisioning procedures
that an OMC operator is able to perform on the UTRAN

Reason for reissue


The reissue reasons for each issue are as follows:

Issue Reissue reason(s)


1 Update to release 04.03.

Intended audience
The audience for this information product includes:
• OMC administrator
• OMC operator

How to use this information product


This information product is created according to a structure that is applicable for all
UMTS OAM&P information products (excluding the manuals that are created by third
party vendors).
To ensure that these information products have a uniform appearance, it is possible that
some topics in this manual are empty and only present for consistency purposes.
Whether or not a topic is relevant for the OMC operator is clearly indicated in the
purpose block or overview block of the appropriate topic.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary lvii
Issue 1, August 2007 See notice on first page
,
About this information product

Conventions used
The following conventions are used in the document:

Graphical representation Description


Emphasis Places attention to a specific word or
phrase.
Command-syntax Indicates the exact command format that
should be entered at the OMC command
line interface.
GUI Indicates the following for a graphical
user interface:
• The name of a window.
• The actions that should be taken on a
pull-down menu.
Key-capture Indicates a key combination on the
keyboard.
Path Indicates a directory path or a file name.
Attribute Indicates that this “word” is a GUI or CLI
attribute (parameter).
<> Indicates that the text between the “< >”
signs should be determined and filled in
by the user.
=> Indicates that a sequence of pull-down
menus should be opened.
→ Indicates the parent-child relation between
two OMC objects.

The term “OMC” refers to the OMC-U and the OMC-UPS.

Information product support


To provide feedback or ask non-technical questions about this and other Lucent
Technologies information products:
• Use the customer comment form at: http://www.lucent-info.com/comments.
• Send E-mail to: comments@lucent.com.
• Call documentation support.
Documentation support telephone numbers are:
– for the continental United States: 1 888 727 3615
– for all countries: 1 630 713 5000
...................................................................................................................................................................................................................................
lviii Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
,
About this information product

Technical support
For technical support, contact your local customer support team. Reach them via the
web at https://support.lucent.com/ or the telephone number listed under the Technical
Assistance Center menu at http://www.lucent.com/contact/.

How to order
Website ordering
To order Lucent Technologies information products, contact your local sales
representative, use the following websites, or use the email, phone, and fax contacts
linked from “Contact Us” on these sites:
• Documentation: http://www.lucentdocs.com
• Training: https://training.lucent.com/
Telephone, fax or email ordering
To order Lucent Technologies information products from an order entry representative
use one of the following:
• Within the United States, call 1-888-582-3688 or send email to
cicorders@lucent.com (to fax an order, call 1-800-566-9568).
• Within Canada, call 1-317-322-6616 or send email to cicorders@lucent.com (to fax
an order, call 1-317-322-6699).
• International, call 1-317-322-6416 or send email to intlorders@lucent.com (to fax
an order, call 1-317-322-6699).

Related documentation
Documents that are related to this information product are:
• UMTS Lucent OMC-UPS Operations, Administration, Maintenance, and
Provisioning, 401-380-022
• UMTS Lucent Managed Object Descriptions, 401-380-071
• UMTS Radio Network Controller Technical Description, 401-382-320
• UMTS Radio Network Controller Operations, Administration and Maintenance
RNC OA&M, 401-382-360
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
+24V, 401-382-462
• Lucent UMTS Modular Cell Outdoor, Operation, Administration and Maintenance
for +24V, 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
+24V, 401-382-961
• Lucent UMTS Microcell (Type M), Operation, Administration and Maintenance for
+24V, 401-382-966
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary lix
Issue 1, August 2007 See notice on first page
,
About this information product

• UMTS Lucent UTRAN Attribute Descriptions, 401-382-801


• SGSN Provisioning, 401-383-380
• CGF Provisioning, 401-383-580

Related training
Training products that are related to this information product:
• UMTS system introduction, UM1001 (for the instructor led version), UM1001C (for
the computer based version), or the UM1001W (for the web based version)
• UMTS Hardware Overview, UM1911 (for the instructor led version), UM1911C
(for the computer based version)
• UMTS Lucent OMC-UPS Network System Administration, UM4712
• UMTS Lucent OMC-UPS Network Configuration & Fault Management, UM4711
• UMTS UTRAN Signaling and Parameters, UM4302

Tasks
This information product describes how to:
• Perform Fault Management on the UTRAN using the OMC
• Perform Configuration Management on the UTRAN using the OMC
• Perform Performance Management on the UTRAN using the OMC

How to comment
To comment on this information product, go to the Online Comment Form
(http://www.lucent-info.com/comments/enus/) or e-mail your comments to the
Comments Hotline (comments@alcatel-lucent.com).

...................................................................................................................................................................................................................................
lx Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
,
Part I: Hazard statements

Overview
...................................................................................................................................................................................................................................

Purpose
This documentation part provides the hazard statements that relate to UTRAN.
There are no physical hazards that are related to the tasks that an OMC operator can
perform on the UTRAN.

Contents

Chapter 1, Hazard statements 1-1

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary I-1
Issue 1, August 2007 See notice on first page
1 H azard statements
1

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides the hazard statements that relate to UTRAN.

References
For more information about the hazard statements of the Lucent Technologies UTRAN
hardware, refer to:
• Lucent RNC Operations, Administration and Maintenance, 401-382-360
• Lucent UMTS Macrocell Indoor, Operation , Administration and Maintenance for
+24 V, 401-382-462
• Lucent UMTS Modular Cell Outdoor Operation, Administration and Maintenance
for +24V , 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
+24V, 401-382-961
• Lucent UMTS Microcell (Type M), Operation , Administration and Maintenance,
401-382-966

Contents

UTRAN hazard statements 1-2

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 1-1
Issue 1, August 2007 See notice on first page
Hazard statements

UTRAN hazard statements


...................................................................................................................................................................................................................................

No hazard statements
There are no hazard statements related to the tasks that an OMC operator can perform
on the UTRAN.

...................................................................................................................................................................................................................................
1-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Part II: System description

Overview
...................................................................................................................................................................................................................................

Purpose
This documentation part includes descriptive information about the UTRAN
components.

Reference
For more information about the technical specifications of the Lucent Technologies
RNC and the Node B, refer to:
• Lucent RNC Technical Description, 401-382-320
• Lucent UMTS Macrocell, Technical Description for -48 V, 401-382-420
• Lucent UMTS Macrocell, Technical Description for -24 V, 401-382-421
• Lucent UMTS Modular Cell Outdoor, Technical Description for +24 V,
401-382-720.

Contents

Chapter 2, UTRAN overview 2-1


Chapter 3, Node B mechanical structure 3-1
Chapter 4, RNC mechanical structure 4-1

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary II-1
Issue 1, August 2007 See notice on first page
2 U TRAN overview
2

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter describes the architecture, functions and maintenance aspects of the
UMTS Terrestrial Radio Access Network (UTRAN).

Overview
The aspects of the UTRAN can be subdivided into the following subjects:
• Architecture and functions
• Elements
• Interfaces
• Transmission equipment
• Operating and Maintenance Center (OMC).

Contents

UMTS network 2-2


UTRAN functions and interfaces 2-5
Node B 2-7
Radio Network Controller 2-8
Operation and Maintenance Center (OMC) 2-10
UTRAN Transmission equipment 2-13

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-1
Issue 1, August 2007 See notice on first page
UTRAN overview

UMTS network
...................................................................................................................................................................................................................................

Overview
The UMTS network architecture consists of three main parts:
• User equipment.
• UTRAN
• Core network

Network architecture
UMTS network architecture:

PSTN/ISDN IP networks

Core network

GMSC HLR 3G-GGSN


AuC
EIR
Circuit switched Packet switched
VLR

3G-MSC 3G-SGSN

Access
network
RNC RNC

Node B Node B

User equipment User equipment

...................................................................................................................................................................................................................................
2-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview UMTS network

User equipment
The term User Equipment (UE) refers to the mobile devices that are used to access
UMTS services.
Examples of UEs are:
• Mobile phone
• Personal Digital Assistant (PDA)
• Laptop personal computer.

Access network
The access network is known as the UMTS Terrestrial Radio Access Network
(UTRAN) and provides user access to the core network. The UTRAN also manages
the radio resources, call setup, and handovers.
A UMTS network may consist of one or more access networks that use different radio
access systems and that are linked to the same core network. Together these networks
form a single UMTS network.
The entities of the UTRAN are:
• Radio Network Controller (RNC)
• Node B.

Core network
The core network provides central switching, transmission and service-provisioning
functions that are required to provide UMTS services.
The entities of the core network are grouped into functional areas:
• Entities to support circuit-switched services
• Entities to support packet-switched services
• Entities that are shared by packet-switched and circuit-switched services.

Circuit-switched entities
The entities of the circuit-switched core network are:
• Mobile Switching Center (3G-MSC)
• Gateway MSC (GMSC)
• Visitor Location Register (VLR).

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-3
Issue 1, August 2007 See notice on first page
UTRAN overview UMTS network

Packet-switched entities
The entities of the packet-switched core network are:
• Serving GPRS Support Node (3G-SGSN)
• Gateway GPRS Support Node (3G-GGSN).

Shared entities
The entities that are shared by the circuit-switched and packet-switched core networks
are:
• Home Location Register (HLR)
• Authentication Center (AuC)
• Equipment Identity Register (EIR).

...................................................................................................................................................................................................................................
2-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview

UTRAN functions and interfaces


...................................................................................................................................................................................................................................

Overview
The UTRAN consists of a series of Radio Network Subsystems (RNS). ’RNS’ is an
abstract term that defines the entities that manage the resources and
transmission/reception for a particular set of cells.

Functions
The functions of the UTRAN are:
• Radio resource management
• Bearer support for packet data
• Call setup and release
• Handover control
• User access to the core network.

Architecture of the UTRAN


Architecture of the UTRAN:

Core network

Iu-cs Iu-ps
Itf-R

OMC

RNC Iur RNC


Itf-B
RNS Iub Iub RNS

Node B Node B Node B Node B

Cell UTRAN

Uu
th
y 20
Ma
y,
sda
Tue
s
sage
Mes
s
tact
Con
e
Offic

r
nda
Cale

User equipment

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-5
Issue 1, August 2007 See notice on first page
UTRAN overview UTRAN functions and interfaces

RNS
Each RNS contains:
• One RNC
• One or more Node Bs.

RNC interfaces
The RNC has the following interfaces:
• Iub interface to the Node Bs
• Iu-cs interface to the circuit-switched core network
• Iu-ps interface to the packet-switched core network
• Iur interface to other RNCs. An RNC can be interconnected to multiple other RNCs
• Itf-R interface to the OMC.

Node B interfaces
The Node B has the following interfaces:
• Uu interface to UEs
• Iub interface to the RNC
• Itf-B interface to the OMC.

...................................................................................................................................................................................................................................
2-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview

Node B
...................................................................................................................................................................................................................................

Functions
The Node B is responsible for:
• Radio transmission and reception to and from the UE
• Termination of ATM Adaptation Layer (AAL) 5 and AAL-2 layers on the Iub
interface
• Call-processing functions, including channel-element resource allocation and
application processing
• OA&M processing, including circuit-pack status monitoring and reporting to the
OMC
• External-alarm inputs and output control
• Antenna connections.

Physical
The Lucent UMTS Node Bs are dedicated to UMTS macro cellular applications and
are available in both indoor and outdoor versions.A single cabinet offers a capacity of
3 sectors on 1 carrier frequency.

Receive diversity
The Lucent UMTS Node Bs supports two-channel antenna diversity for the uplink.
Each antenna uses a separate receiver. The data from the receivers is combined. This
improves the signal-to-noise ratio.

Tower Top Low Noise Amplifier


The Lucent UMTS Node Bs supports interfaces for up to six Tower Top Low Noise
Amplifiers (TTLNA). The TTLNA improves the receiver noise and compensates for
cable losses and thus improves the cell capacity.

Antenna-tilt interface
The Lucent UMTS Node Bs supports an optional electrical antenna-tilt control
interface.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-7
Issue 1, August 2007 See notice on first page
UTRAN overview

Radio Network Controller


...................................................................................................................................................................................................................................

Functions
The RNC is primarily responsible for:
• Supporting of call setup, maintenance and tear down
• Management of radio resources
• Management of UE mobility in the UTRAN.

Call setup
Support of call setup, maintenance and tear down includes:
• Handling of call-admission requests (including integrity checks on signaling
messages)
• Establishing, maintaining and deleting signaling bearers towards a UE
• Establishing, maintaining and deleting radio bearers (at agreed QoS levels) towards
a UE
• Handling the routing of end-user voice and/or data traffic between the core network
and supporting Node Bs
• Implementing the ciphering of user traffic and control-plane signaling.

Radio resources
Management of radio resources includes:
• Setting power-level targets
• Allocating radio-channel codes.

UE mobility
Management of UE mobility in the UTRAN includes:
• Performing hard/soft/softer handovers.

RNC types
Types of RNC:
• Serving RNC (SRNC)
• Drift RNC (DRNC).

Serving RNC
The SRNC controls the connection of an established call between the UE and the
UTRAN. The SRNC is the RNC where the UE originates a call.

...................................................................................................................................................................................................................................
2-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview Radio Network Controller

Drift RNC
When the UE roams, the DRNC can support the SRNC by providing radio resources.
This is the case when the UE roams to cells that are not under the control of the
SRNC.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-9
Issue 1, August 2007 See notice on first page
UTRAN overview

Operation and Maintenance Center (OMC)


...................................................................................................................................................................................................................................

Overview
The OMC is used for maintenance of the UTRAN. The OMC provides the Element
Management (EM) functions of the UTRAN. The OMC offers management of the
UTRAN from a centralized location.
Functions of the OMC are:
• Fault management
• Configuration management
• Performance management
• Security management
• Inventory management
• Software management
• Support for Network Management Systems (NMS).

OA&M reference model


The OA&M reference model:

...................................................................................................................................................................................................................................
2-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview Operation and Maintenance Center (OMC)

Network Management System


ICM IIM IPM IFM NML

Itf-N
OMC
Integrated SNM
EML
Node B RNC
EM EM

Itf-B Itf-R

Iub
NodeB RNC NEL

RMT/LMT LMT

Layers
The layers of the OA&M reference model are:
• Network Management Layer (NML)
• Element Management Layer (EML)
• Network Element Layer (NEL).
The OMC is part of the EML.

NML systems
Systems within the Network Management Layer are:
• Integrated Fault Management (IFM)
• Integrated Configuration Management (ICM)
• Integrated Performance Management (IPM)
• Integrated Inventory Management (IIM).

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-11
Issue 1, August 2007 See notice on first page
UTRAN overview Operation and Maintenance Center (OMC)

OMC functional blocks


The functional blocks within the OMC are:
• Sub-Network Management (SNM) integrates all managed sub-network elements
• RNC Element Manager (EM) integrates all RNC management agents
• Node B EM integrates all Node B management agents.

OMC interfaces
The OMC has the following interfaces:
• Itf-N between the OMC and the NMS (also named Northbound interface)
• Itf-R between the OMC and an RNC.
• Itf-B between the OMC and a Node B.

OMC connectivity
The OMC needs to connect to the UTRAN elements via both IP and ATM protocols.
The OMC can use an existing IP and/or an ATM infrastructure to connect with the
UTRAN elements.
Methods of transporting OA&M traffic via the Itf-R and Itf-B interfaces from the
OMC to the RNC and the Node B:
• In-band across the ATM network
• Separate data-connection network.
If the RNC is co-located with an ATM edge switch, the OA&M traffic from the OMC
to the Node B via the Itf-B can be sent on the physical links that are used for the Iub
traffic.

RNC Local Maintenance Terminal


The Local Maintenance Terminal (LMT) acts as an EM terminal that provides access
to element-management functions for the RNC. A laptop or desktop PC can be used as
an LMT via a connection with the Local Area Network (LAN) connection of the RNC.

Remote Maintenance Terminal


The Remote Maintenance Terminal (RMT) acts as an EM terminal that provides access
to element-management functions for the Node B. A laptop or desktop PC can be used
as an RMT via a connection with the LAN connection of the Node B.

Node B Local Maintenance Terminal


The Node B Local Maintenance Terminal (LMT) acts as an EM terminal that provides
access to element-management functions for the Node B. A laptop or desktop PC can
be used as an LMT via an Ethernet connection to the Ethernet port of the Node B.
...................................................................................................................................................................................................................................
2-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN overview

UTRAN Transmission equipment


...................................................................................................................................................................................................................................

Overview
Network provisioning for the transmission equipment of the 3G wireless networks uses
the methods that are used for wireline networks. A transport network may have either
SDH or SONET equipment. Typically, the transmission equipment in the transport
networks consists of multiplexers that are arranged in ring configurations. The transport
network has to provide Internet Protocol (IP) over Asynchronous Transfer Mode
(ATM).

ATM network transport model


ATM network transport model:

OMC-CS Core network


ethernet

STM-1 STM-1 OMC-UPS

edge edge ethernet


device device

ATM
edge
device transport
network
OMC-T ethernet
ethernet
edge edge
device RNC
device
STM-1
4xE1 4xE1

Node B Node B

Transmission equipment
Types of transmission equipment:
• Edge devices, for example: switches and access concentrators
• ATM end users, for example: Node B, RNC, 3G-MSC, and 3G-SGSN
• ATM backbone switches in the ATM transport network.

ATM provisioning
ATM provisioning consists of the provisioning of ATM network elements within the
different domains of the UMTS network.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 2-13
Issue 1, August 2007 See notice on first page
UTRAN overview UTRAN Transmission equipment

Domains of the UMTS network:


• UTRAN
• Circuit-switched
• Packet-switched.
Each domain is managed by its distinct OMC.
Once ATM connections are established, they remain fairly static unless addition or
deletion of equipment is required. For example, when you add an RNC in the UTRAN,
the corresponding ATM network elements for the Itf-R, Itf-B, Iu-cs, Iu-ps and Iur
interfaces must be established.

ATM network management


ATM provisioning is managed by a centralized network-management system. This
system will send the ATM configuration commands to the appropriate OMCs.
Each OMC, in turn, will send the appropriate set of commands to the NEs within its
domain.

IP network provisioning
The UMTS network has IP components in the access, circuit, transport, and packet
domains. Each of these domains contains elements that need configuration files and IP
addresses for equipment initialization.

IP network management
For network provisioning, the IP addresses are static. There is no direct need to
centralize the provisioning of IP addresses. However, it is essential that an inventory of
IP addresses is maintained. VitalQIP ™ can be used to maintain this inventory.

...................................................................................................................................................................................................................................
2-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
3 N ode B mechanical structure
3

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter contains the mechanical structure diagrams and component numbering of
the different Lucent UMTS Node B models.
These diagrams can be used by the OMC operator to determine:
• The Node B hardware that is available
• The location of the hardware within the Node B cabinet.

Contents

Structure of the Lucent UMTS Macrocell Indoor for +24V 3-3


Mechanical structure of the Lucent UMTS Macrocell Indoor 3-4
Component numbering in the Lucent UMTS Macrocell Indoor 3-8
Structure of the Lucent UMTS Macrocell Compact Indoor for +24V 3-11
Mechanical structure of the Lucent UMTS Macrocell Compact Indoor 3-12
Component numbering in the Lucent UMTS Macrocell Compact Indoor 3-16
Structure of the UMTS Lucent Macrocell Compact Outdoor for 3-18
+24V
Mechanical structure of the Lucent UMTS Macrocell Compact Outdoor 3-19
Component numbering in the Lucent UMTS Macrocell Compact Outdoor 3-23
Structure of the UMTS Lucent UMTS Modular Cell Outdoor for 3-25
+24V
Mechanical structure of the UMTS Modular Cell Outdoor 3-26
Component numbering in the UMTS Modular Cell Outdoor for +24 V 3-32
Structure of the UMTS Lucent Microcell for +24V 3-35

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-1
Issue 1, August 2007 See notice on first page
Node B mechanical structure Overview

Mechanical structure of the Lucent UMTS Microcell Outdoor 3-36


Component numbering in the Lucent UMTS Microcell Outdoor 3-41

....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Structure of the Lucent UMTS Macrocell Indoor for


+24V

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the mechanical structure diagrams and component numbering of
the different models of the UMTS Lucent Macrocell.

Related information
For more information about the Lucent UMTS Macrocell Indoor, refer to:
• Lucent UMTS Macrocell +24V Technical Description, 401-382-421.

Contents

Mechanical structure of the Lucent UMTS Macrocell Indoor 3-4


Component numbering in the Lucent UMTS Macrocell Indoor 3-8

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-3
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Mechanical structure of the Lucent UMTS Macrocell Indoor


...................................................................................................................................................................................................................................

Overview
The Lucent UMTS Macrocell Indoor offers the opportunity for expansion to
configurations with more carriers and/or sectors, power, Tx diversity etc. by simply
adding the necessary circuit packs, amplifiers, etc.

Inside view of a single-band configuration


Lucent UMTS Macrocell Indoor (type F) with door removed,
3s1c configuration without Tx diversity, minimum UCU population, two fan trays:
J41

J41

J41
LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J2-C

J22-C

J2-C

J22-C

J2-C

J22-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

Filter shelf
Filter units
J24

J24

J24
J4

J4

J4
DIV0

DIV0

DIV0
J25

J25

J25
DIV1

DIV1

DIV1
J5

J5

J5
J26

J26

J26
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8

J1 J2 J3 J4 J5 J6 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J16 J17 J18 J19

J20 J21 J22 J23 J24 J25 J26 J27 J28 J29
DS1

CB1
CBs CB2
FAC
J7
-48VDC

Blank

Blank

Fan
(rear venting)
Amplifier shelf

AMPs

CB5-J16
J16

ESD
J1 J2 J3 J4

D C
J13
IN 1
J H
B
3
F
J5

PDP
A
5
E
J6 J7 J8

C
7
F
J14
B
9
E
A
11
D
J9 J10 J11 J12

PDP I-2C nnVDC CB1-J1-J2-J3 CB2-J4-J5-J6 OUT 2 4 6 8 10 12


CB3-J7-J8-J9 CB4-J10-J11-J12

Blank

Fan
(rear venting)
Digital shelf

Circuit packs

IOU OM CPCs

...................................................................................................................................................................................................................................
3-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Indoor

Inside view of a dual-band configuration


Lucent UMTS Macrocell Indoor (type F) with door removed, dual-band configuration
with single fan tray:

J41

J41

J41
LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J2-C

J22-C

J2-C

J22-C

J2-C

J22-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA
J24
Filter units

J24

J24
J4

J4

J4
DIV0

DIV0

DIV0
J25

J25

J25
DIV1

DIV1

DIV1
J5

J5

J5
J26

J26

J26
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8

Filter shelf
J41

J41

J41
LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J2-C

J22-C

J2-C

J22-C

J2-C

J22-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA
Filter units
J24

J24

J24
J4

J4

J4
DIV0

DIV0

DIV0
J25

J25

J25
DIV1

DIV1

DIV1
J5

J5

J5
J26

J26

J26
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8

FAC4 J1

J20
J2 J3

J21
J4 J5

J22
J6 J7

J23
J8 J9

J24
J10 J11

J25
J12

SEC-B
J13

J26
DS1
J14

J27
J16 J17

J28 J29
J18 J19

Blank
CBs

Blank

CB5-J16

PDP I-2C nnVDC


J16

ESD
J1

CB1-J1-J2-J3
J2 J3

CB2-J4-J5-J6
J4

D
IN
J
J13
C
1
H
OUT 2
B
3
F
4
J5

PDP
A
5
E
6
J6 J7 J8

C
7
F
8
J14
B

E
9

10
A
11
D
12
J9 J10 J11

CB4-J10-J11-J12
J12

GREEN = NORMAL
RED = FAULT

KS-24563 L3 FAN TRAY


Fan Amplifier shelf
(rear venting)
0 12 AIRFLOW PROFILE SETTING #1
9
8 4
3 USED WITH
7 65 AMPLIFIER, OUTDOOR CABINET
(Application per top-plate label)

1 2 3 4 5 6 7 8 9 10 11 12

J16 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12

CB5-J16
RF IN RF IN RF IN J13 RF IN J14
RF IN RF IN
D C B A C B A
IN 1 3 5 7 9 11
ESD J H F E F E D

PDP I-2C nnVDC CB1-J1-J2-J3 CB2-J4-J5-J6 OUT 2 4 6 8 10 12


CB3-J7-J8-J9 CB4-J10-J11-J12
ALM ALM ALM ALM ALM ALM
ACT P2PAM ACT C2PAM ACT P2PAM ACT C2PAM ACT P2PAM ACT C2PAM

AMPs

RF OUT RF OUT RF OUT RF OUT RF OUT RF OUT

A12 AMPLIFIER SUBRACK

UCU48v UCU48v CTU-II


URC-II P1.5 P1.5
MCR1900 MCR1900 MCR1900 MCR850 MCR850 MCR850
OCXO P1.5 P1.5 P1.5 P1.5 P1.5 P1.5
44WW65 BNJ 24 BNJ 24 BNJ35B
BNJ 50 BNJ 50 BNJ 50 BNJ 50 BNJ 50 BNJ 50
1:1
1:1

Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent

L-ETH GIG-E

TX1 TX1 TX1 TX1 TX1 TX1


Digital shelf

TX ON TX ON TX ON TX ON TX ON TX ON

TX OFF TX OFF TX OFF TX OFF TX OFF TX OFF

U-ETH
TX2 TX2 TX2 TX2 TX2 TX2
GIG-E
TONE TONE TONE TONE TONE TONE
STAT
FAIL FAIL
MVM Load MVM Load STAT STAT STAT STAT STAT STAT
TIM 1
ACT ACT

Circuit packs
TX1-ON TX1-ON TX1-ON TX1-ON TX1-ON TX1-ON

L2 L1 TX2-ON TX2-ON TX2-ON TX2-ON TX2-ON TX2-ON

L4 L3
RC1 RC1 RC1 RC1 RC1 RC1
L6 L5

L8 L7
RX1 RX1 RX1 RX1 RX1 RX1

RC2 RC2 RC2 RC2 RC2 RC2


T1 / E1

RX2 RX2 RX2 RX2 RX2 RX2

URC MCR MCR MCR MCR MCR MCR

User Alarms E1/T1 E1/T1 Shelf


0-15 16-31 AMP.AI. Config. ID Sel. Ethernet/Select

J9
J17
15.00 MHz 15.00 MHz
J13 J12 OUT ø OUT ø

J7 J8 J1
J3 J14 J6
J16

IOU JTAG
J18

Cab.AI. UDRV
J4

422 Bus
J5
15.00 MHz
OUT 1

OMA
OM FAIL
RDY
15.00 MHz
OUT 1

OMQ
FAIL
RDY 5V
3.3V
FAIL
RDY

CPC-A
48V
FAIL
RDY
5V
3.3V

CPC-A
48V
CPCs FAIL
RDY
15V
8V
1.5V

CPC-B
48V
15V
8V
1.5V
FAIL
RDY

CPC-B
48V

FAN TRAY FILTER SHELF


15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2)
ESD
DIGITAL SHELF POWER GND
FAN TRAY POWER

Shelves
The Macrocell Indoor contains the following shelves:
• Filter shelf
• Amplifier shelf
“Note”: The amplifier shelf might be replaced by blanking plates for Multiple
Carrier Power Amplifier (MCPA) configurations.
• Digital shelf
....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-5
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Indoor

Shelves and their components


The Macrocell Indoor shelves are equipped with the following components:

Shelf Components
Filter shelf The filter shelf contains the following components:
• Filter panels
• Filter Access Card (FAC)
• Circuit Breakers (CBs)
• E1/T1 Secondary Protection (SEC-B)
Amplifier shelf The amplifier shelf contains the following components:
• Amplifier modules (AMPs)
• Splitters and combiners, if required
• Power Distribution Panel (PDP)
• Fan tray (configured for amplifier shelf position)
• Blanking modules.
Additional information:
The amplifier shelf might be replaced by blanking plates
for MCPA configurations. In that case the output signals
from the radio units are routed via the hatchplate to the
external amplifiers.
Digital shelf The digital shelf contains the following components:
• Circuit packs,
comprising the following units:
– Universal Radio Controller (URC)
– UMTS Channel Units (UCUs)
– Common Timing Unit (CTU)
– Multi-Carrier Radios (MCRs).
• Blanking modules
• Input Output Unit (IOU)
• Oscillator Modules (OMs)
• Common Power Converters (CPCs)
• Fan tray (configured for digital shelf position). This
fan tray is omitted in case of “Single Fan Tray”
configuration.

....................................................................................................................................................................................................................................
3-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Indoor

Receiver preamplifiers
Low Noise Amplifiers (LNAs) can be used as receiver preamplifiers in the various
frequency ranges. Depending on frequency ranges and mounting options these LNAs
are variously denoted.
The DxTMAs are optional Tower Mounted Amplifiers (could also be mounted on a
wall) and provide two independent pre-amplification branches.

Top view
At the top of the Macrocell Indoor external connections are made. Besides the earth
connectors three connector areas can be distinguished:

RF
connectors

Hatch
Power
plate
connectors

Earth
connectors

Legend:

RF connectors Six connectors to connect the external antennas to the RF filter


units (duplexers).
Power connectors Three independent power supply lines are connected here.
Hatch plate All digital signaling and alarms are connected here.
Earth connectors Screws to connect protection earth.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-7
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Component numbering in the Lucent UMTS Macrocell Indoor


...................................................................................................................................................................................................................................

Component numbering full capacity cabinet


The following figure is a schematic diagram, and is not to scale. The components to be
fitted depend on the actual configuration:

1 2 3

Filter Panels

Filter shelf
4 5 6

CB FAC

Fan tray

Amplifier Modules

Amplifier shelf
1 2 3 4 5 6 7 8 9 10 11 12

PDP

Fan tray
MCR
MCR
MCR
MCR
MCR
MCR
URC
URC
URC
URC
UCU
UCU
UCU
UCU
UCU
UCU

UCU
UCU
UCU
UCU
UCU
UCU
CTU
CTU

Digital shelf

1 2 3 4 1 2 3 4 5 6 1 2 1 2 3 4 5 6 7 8 9 10 11 12

OM CPCA CPCB
IOU
1 2 1 2 3 4 5 6 7 8

...................................................................................................................................................................................................................................
3-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Component numbering in the Lucent UMTS Macrocell
Indoor

This figure is an example for a dual-band configured UMTS Node B. For single-band
configurations, only the corresponding MCR, UCU, filters and amplifier modules are
equipped. For Single Fan Tray configurations, the digital shelf fan tray is omitted, the
amplifier modules are located directly above the digital shelf and the PDP is located
above the amplifier shelf fan tray.
Important! The following sections only list components of which there can be
more than one in the Macrocell Indoor.

Component numbering in the filter shelf


The components are numbered as follows:

Component Numbering
Filter panels The filter panels are numbered from left to right, starting
with the upper row, from 1 to 3 and continuing in the
lower row from 4 to 6. The upper row is used for 1900
MHz or 2100 MHz, the lower row for 850 MHz filters.

Component numbering in the amplifier shelf


The components are numbered as follows:

Component Numbering
Amplifier Modules The Amplifier Modules are numbered from left to right,
from 1 to 12. Slots are alternatively assigned in pairs to
2100/1900 MHz and 850 MHz amplifiers: slots 1/2, 5/6
and 9/10 for 2100/1900 MHz, slots 3/4, 7/8 and 11/12 for
850 MHz.

Component numbering in the digital shelf


The components are numbered as follows:

Component Numbering
URC The Universal Radio Controllers (URC) are numbered
from left to right, from 1 to 4.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-9
Issue 1, August 2007 See notice on first page
Node B mechanical structure Component numbering in the Lucent UMTS Macrocell
Indoor

Component Numbering
UCU The UMTS Channel Units (UCU) are numbered from left
to right, from 1 to 6 (in the left part) and from 7 to 12
(in the right part). The UCUs are pooled resources for 2
groups of 6 UCUs. It is recommended to populate the
UCUs in consecutive order, starting with “1”.
CTU The Common Timing Unit(s) (CTU) are numbered from
left to right, 1 and 2.
MCR The Multi-Carrier Radios (MCR) are numbered from left
to right, from 1 to 6. Slots 1 to 3 are assigned for
2100/1900 MHz radios, slots 4 to 6 are assigned to 850
MHz radios.
OM The Oscillator Module(s) (OM) are numbered from the
left to the right, 1 and 2.
CPC The Common Power Converters (CPC) are numbered
from left to right, from 1 to 4 (CPC-A) and from 5 to 8
(CPC-B).

....................................................................................................................................................................................................................................
3-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Structure of the Lucent UMTS Macrocell Compact


Indoor for +24V

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the mechanical structure diagrams and component numbering of
the Lucent UMTS Macrocell Compact Indoor.

Related information
For more information about the Lucent UMTS Macrocell Compact, refer to:
• Lucent UMTS Macrocell Compact Technical Description for +24V, 401-382-921.

Contents

Mechanical structure of the Lucent UMTS Macrocell Compact Indoor 3-12


Component numbering in the Lucent UMTS Macrocell Compact Indoor 3-16

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-11
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Mechanical structure of the Lucent UMTS Macrocell Compact


Indoor
...................................................................................................................................................................................................................................

Inside view
View of the Lucent UMTS Macrocell Compact Indoor with open door (3s1c
configuration without Tx diversity, minimum UCU population):
Lucent Technologies

J41

J41

J41

TEST PULSE
LUCENT-SN XXXXXXXXXXX

LUCENT-SN XXXXXXXXXXX

LUCENT-SN XXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

J20
J22-C

J22-C

J22-C

J1
J2-C

J2-C

J2-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

J2
Filter units

J3
TEST CLOCK

J4
J26 J25 J24

J26 J25 J24

J26 J25 J24


J4

J4

J4

J21

J5
DIV0

DIV0

DIV0
DIV1

DIV1

DIV1
J5

J5

J5

J22

J6

Blank
J6

J6

J6

J7
J23

J8
J11

J11

J11
J31

J31

J31
J7

J7

J7

J9
J24

J10
J25
J28

J28

J28
J8

J8

J8

J11
Filter shelf

J12
J13
J26

DS1

J14
J16
J27
15MHz IN 15MHz OUT

J28
Blank

J17
J29
I2C IN

J18
I2C OUT

J19
CBs

UTDU
FAC
Blank

CB2
CB1
J1

J3
J7
J2

AMPs
(rear venting)

Hybrid shelf
RDY
FAIL
Fan

OMR

CPCs OMR
15.00 MHz

15.00 MHz
OUT ø

OUT 1
C P C -B
4 8V
RDY
FAIL

8V
15V

1.5V

C P C -A
4 8V
RDY
FAIL

5V
3.3V
U

U
D

D
T

T
1

2
Lucent

BIAS-T
CTU

15.00

OUT
MHz

RDY
NVM

OM
FAIL
FLY
EX
FAIL
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx2
Tx1

R x1

R x2
P1.5

BarCodeArea

PDPs
Fail
R eady

Tx O N

Fault
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx1

Tx2

R x1

R x2
P1.5

BarCodeArea
Tx O N

Fail
R eady

Fault
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx1

Tx2

R x1

R x2
P1.5

BarCodeArea
Tx O N

Fail
R eady

Fault

15 MHz
IN (2)
M VM Load
Lucent
U C U 48v

BNJ 24
P1.5

BarCodeArea
FAIL

AC T

15 MHz
M VM Load
Lucent

IN (1)
U C U 48v

BN J 24
P1.5

BarCodeArea
FAIL

AC T

Circuit packs
OUT (2)
M VM Load

15 MHz
Lucent
U C U 48v

BNJ 24
P1.5

BarCodeArea
FAIL

AC T
3
4

GREEN = NORMAL
0 12

7 65

RED = FAULT
M VM Load
Lucent

OUT (1)
U C U 48v

15 MHz
9
8

BN J 24
P1.5

BarCodeArea
FAIL

AC T

FAN TRAY POWER


FILTER SHELF
Lucent
URC

C
A

B
L1
NVM

RDY

L2
FAIL

L3
L4

HIOU
FAN TRAY POWER
FAN TRAY

Shelves
The Lucent Macrocell Compact Indoor contains the following shelves:
• Filter shelf
• Hybrid shelf.

Shelves and their components


The Lucent Macrocell Compact Indoor shelves are equipped with the following
components:

Shelf Components
Filter shelf • Filter panels
• Filter Access Card (FAC)
• Circuit Breakers (CBs)
A one unit (1 U) tall space below the filters is available
to mount customer supplied facilities equipment.

...................................................................................................................................................................................................................................
3-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Compact Indoor

Shelf Components
Hybrid shelf • Amplifier Modules (AMPs)
• Splitters and combiners, if required
• Power Distribution Panel (PDP-1)
• Circuit packs,
comprising:
– Universal Radio Controller (URC)
– UMTS Channel Units (UCUs)
– Common Timing Unit (CTU)
– Multi-Carrier Radio (MCR)
• Hybrid Input Output Unit (HIOU)
• Oscillator Module (OM)
• Common Power Converter (CPC)
• Fan tray
• Blanking modules.

Optional components
The following optional component can be installed in the Lucent UMTS Macrocell
Compact Indoor:
• Power Distribution Panel (PDP-3) can be mounted directly to the right of the
digital section of the hybrid shelf, when more than three Amplifier Modules are
installed.

Installation options
Installation options for the Lucent UMTS Macrocell Compact Indoor:
• Basic plinth, can be used as a mounting pedestal for the cabinet.
• battery plinth containing a single string of four backup batteries.
View of the installation options for the Lucent UMTS Macrocell Compact Indoor:

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-13
Issue 1, August 2007 See notice on first page
3-14
Top view
DIV0
LUCENT-CC XXXXXXXXX

J8
J11
LUCENT-SN XXXXXXXXXXX

J20
J1

RED = FAULT
TEST PULSE
J2-C
J6 J5 J4

J2

GREEN = NORMAL
J3
J7 RF ON TTLNA LNA

J4

J21

TEST CLOCK
J5
J41

J22
0 12
RF ON TTLNA LNA

J6
9 3
8 4 J28
7 65

J7
J31
Lucent Technologies

J26 J25 J24 J22-C

J23
J8
J9

J24
J10

J25
DIV1

J11
J12
DIV0
LUCENT-CC XXXXXXXXX

J13
U C U 48v U C U 48v U C U 48v U C U 48v U C R 2100 U C R 2100 U C R 2100
URC P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 CTU J8
BN J 24 BNJ 24 BN J 24 BN J 24 BNJ 26 BN J 26 BNJ 26 J11
LUCENT-SN XXXXXXXXXXX

J26
Lucent Lucent Lucent

DS1
Lucent Lucent Lucent Lucent Lucent Lucent

J14
J2-C
J6 J5 J4

J16

J27
J7 RF ON TTLNA LNA

J28
J17
T
D
U
1 FAIL
FAIL

J29
RDY
J41
Tx1 Tx1 Tx1 RDY

15MHz IN 15MHz OUT


5V
15V
3.3V
FAIL 8V RF ON TTLNA LNA
T 1.5V
Node B mechanical structure

J18
NVM Tx O N /O FF Tx O N /O FF Tx O N /O FF J28
U

I2C IN
2
RDY C P C -A C P C -B J31
4 8V 4 8V J26 J25 J24 J22-C
L1 Tx2 Tx2 Tx2

J19
L2 15.00

I2C OUT
MHz
L3 R eady R eady R eady
OUT
FAIL FAIL FAIL FAIL
Tx O N Tx O N Tx O N
L4 M VM Load M VM Load M VM Load M VM Load
Fault Fault Fault
AC T ACT AC T ACT
FAIL
Fail Fail Fail DIV1

UTDU
NVM

RDY
A DIV0
OM LUCENT-CC XXXXXXXXX
FAIL
15.00 MHz
FLY OUT ø
R x1 R x1 R x1 EX J2 J1 J8
J11
LUCENT-SN XXXXXXXXXXX
B

BarCodeArea
BarCodeArea
BarCodeArea

BarCodeArea
BarCodeArea
BarCodeArea
BarCodeArea
J2-C
BIAS-T J6 J5 J4
15.00 MHz FAIL
OUT 1
C RDY
R x2 R x2 R x2
J7 RF ON TTLNA LNA

OMR
J41
J3 RF ON TTLNA LNA
FAN TRAY FILTER SHELF J7 J28
15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2) J31
J26 J25 J24 J22-C

basic plinth
FAN TRAY POWER FAN TRAY POWER

with optional
DIV1

Indoor cabinet
J27 J26 J25 TEST CLOCK TEST PULSE
15MHz IN 15MHz OUT J24 J23 J22
DS1
I2C OUT I2C IN
CB1 J29 J28 J21 J20

UTDU
J19 J18 J17 J16 J14 J13 J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1

CB2

DIV0
LUCENT-CC XXXXXXXXX

J8
J11
LUCENT-SN XXXXXXXXXXX
J20
J1

RED = FAULT
TEST PULSE

J2-C
J6 J5 J4
J2

GREEN = NORMAL
J3

J7 RF ON TTLNA LNA
J4

J21

TEST CLOCK
J5

J41
J22

0 12
RF ON TTLNA LNA
J6

9 3
8 4 J28
7 65
J7

J31
Lucent Technologies

J26 J25 J24 J22-C


J23
J8
J9

J24
J10

J25

DIV1
J11
J12

DIV0
LUCENT-CC XXXXXXXXX
J13

U C U 48v U C U 48v U C U 48v U C U 48v U C R 2100 U C R 2100 U C R 2100


URC P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 CTU J8
BNJ 24 BNJ 24 BNJ 24 BN J 24 BN J 26 BN J 26 BN J 26 J11
LUCENT-SN XXXXXXXXXXX
J26

Lucent Lucent Lucent


DS1

Lucent Lucent Lucent Lucent Lucent Lucent


J14

J2-C
J6 J5 J4
J16

J27

J7 RF ON TTLNA LNA
J28
J17

T
D
U
1 FAIL
FAIL
J29

RDY
J41
Tx1 Tx1 Tx1 RDY
15MHz IN 15MHz OUT

5V
15V
3.3V
FAIL 8V RF ON TTLNA LNA
T 1.5V
D
J18

NVM Tx O N /O FF Tx O N /O FF Tx O N /O FF J28
U
I2C IN

2
RDY C P C -A C P C -B J31
4 8V 4 8V J26 J25 J24 J22-C
L1 Tx2 Tx2 Tx2
J19

L2 15.00
I2C OUT

MHz
L3 R eady R eady R eady
OUT
FAIL FAIL FAIL FAIL
Tx O N Tx O N Tx O N
L4 M VM Load M VM Load M VM Load M VM Load
Fault Fault Fault
AC T ACT AC T AC T
FAIL
Fail Fail Fail DIV1
UTDU

NVM

RDY
A DIV0
OM LUCENT-CC XXXXXXXXX
FAIL
15.00 MHz
FLY OUT ø
R x1 R x1 R x1 EX J2 J1 J8
J11
LUCENT-SN XXXXXXXXXXX
B
BarCodeArea
BarCodeArea
BarCodeArea

BarCodeArea
BarCodeArea
BarCodeArea
BarCodeArea

J2-C
BIAS-T J6 J5 J4
15.00 MHz FAIL
OUT 1
C RDY
R x2 R x2 R x2
J7 RF ON TTLNA LNA

OMR
J41
J3 RF ON TTLNA LNA
FAN TRAY FILTER SHELF J7 J28
15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2) J31
J26 J25 J24 J22-C
FAN TRAY POWER FAN TRAY POWER

with optional
battery plinth

See notice on first page


DIV1

Indoor cabinet
J27 J26 J25 TEST CLOCK TEST PULSE
15MHz IN 15MHz OUT J24 J23 J22
DS1
I2C OUT I2C IN
CB1 J29 J28 J21 J20

UTDU
J19 J18 J17 J16 J14 J13 J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1

CB2

Alcatel-Lucent - Proprietary
Besides the earth connectors three connector areas can be distinguished:
At the top of the Lucent Macrocell Compact Indoor external connections are made.

Issue 1, August 2007


401-382-290R04.03
Compact Indoor
Mechanical structure of the Lucent UMTS Macrocell

....................................................................................................................................................................................................................................
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Compact Indoor

RF connectors

Battery cable
port

1 2 3 4 5 6

GPS
connector

E1/T1
ALARMS (0-7)
(1-4)

E1/T1
(5-8)
ETR
SECB 1
Earthing points
RET

ALARMS (16-29)
SECB 1 RELAY (2-3)

Hatch plate
(e.g. T1/E1 and alarms)

Legend:

RF connectors Six connectors to connect the external antennas to the RF filter


units (duplexers) and one GPS connector.
Antenna and GPS connections are made at the top of cabinet in
the notched area.
Hatch plate All digital signaling and alarms are connected here.
Battery cable port Entry for DC cables into the cabinet.
Earthing points Screws to connect protection earth.

Receiver preamplifiers
Low Noise Amplifiers (LNAs) can be used as receiver preamplifiers in the various
frequency ranges. Depending on frequency ranges and mounting options these LNAs
are variously denoted.
The DxTMAs are optional Tower Mounted Amplifiers (could also be mounted on a
wall) and provide two independent pre-amplification branches.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-15
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Component numbering in the Lucent UMTS Macrocell


Compact Indoor
...................................................................................................................................................................................................................................

Component numbering full capacity cabinet


Component numbering (schematic diagram, not to scale. The components that are to be
fitted depend on the actual configuration):

Filter Panels
1 2 3

Blank Filter shelf


Blank

Blank FAC

6
5
Amplifier 4
Modules 3
2
1
Hybrid Fan Tray

(B) 2
CPC

OM
(B) 1
(A) 2 (A) 1
Hybrid shelf
CTU 2
1
PDP
3
MCR 2
1
4
3
UCU 2
1
2
URC 1

HIOU 1 2

Power shelf

Important! The following sections only list components of which there can be
more than one in the Lucent Macrocell Compact.

Component numbering in the filter shelf


The components are numbered as follows:

Component Numbering
Filter panels Left to right, from 1 to 3.

...................................................................................................................................................................................................................................
3-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Component numbering in the Lucent UMTS Macrocell
Compact Indoor

Component numbering in the hybrid shelf


The components are numbered as follows:

Component Numbering
Amplifier Modules (AMP) From bottom to top, 1 to 6.
Universal Radio From bottom to top, 1 to 2.
Controllers (URCs)
UMTS Channel Units From bottom to top, 1 to 4.
(UCUs)
Multi-Carrier Radios From bottom to the top, 1 to 3.
(MCRs)
Common Timing Units From bottom to top, 1 and 2.
(CTUs)
Common Power Converters From right to left, 1 to 2.
Type A (CPC-A)
Common Power Converters From bottom to top, 1 to 2.
Type B (CPC-B)
Power Distribution Panel The first, PDP-1, is integrated into the Hybrid Shelves’
(PDP) Power Distribution Assembly (PDA).
The optional , PDP-3, can be mounted directly to the
right side of the hybrid shelf when more than three
AMPs are installed.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-17
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Structure of the UMTS Lucent Macrocell Compact


Outdoor for +24V

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the mechanical structure diagrams and component numbering of
the UMTS Lucent Macrocell Compact Outdoor.

Related information
For more information about the Lucent UMTS Macrocell Compact, refer to:
• Lucent UMTS Macrocell Compact Technical Description, 401-382-921.

Contents

Mechanical structure of the Lucent UMTS Macrocell Compact Outdoor 3-19


Component numbering in the Lucent UMTS Macrocell Compact Outdoor 3-23

...................................................................................................................................................................................................................................
3-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Mechanical structure of the Lucent UMTS Macrocell Compact


Outdoor
...................................................................................................................................................................................................................................

Inside view
View of the Lucent UMTS Macrocell Compact Outdoor with door removed (3s1c
configuration without Tx diversity, minimum UCU population):

J41

J41

J41
LUCENT-SN XXXXXXXXXXX

LUCENT-SN XXXXXXXXXXX

LUCENT-SN XXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J22-C

J22-C

J22-C
J2-C

J2-C

J2-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

Blank
Filter units
J26 J25 J24

J26 J25 J24

J26 J25 J24


J4

J4

J4
DIV0

DIV0

DIV0
DIV1

DIV1

DIV1
J5

J5

J5
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8
Filter shelf
Blank
CBs
FAC

CB2
CB1
Blank
J1

J3
J7
J2
Common I/O panel
Heat exchanger

AMPs
(optional)

Fan Tray

Heater (optional)
RDY
FAIL

Hybrid shelf
OMR
15.00 MHz

15.00 MHz
OUT ø

OUT 1

CPCs OMR
C P C -B
4 8V
RDY
FAIL

8V
15V

1.5V

C P C -A
4 8V
RDY
FAIL

5V
3.3V
U

U
D

D
T

T
1

2
Lucent

BIAS-T
CTU

15.00

OUT
MHz

RDY

FAIL
FLY
EX
OM
NVM
FAIL
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx2
Tx1

R x1

R x2
P1.5

BarCodeArea
Fail
R eady

Tx O N

Fault
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx1

Tx2

R x1

R x2
P1.5

BarCodeArea
Fail
Tx O N
R eady

Fault

PDP
Tx O N /O FF
Lucent
U C R 2100

BN J 26

Tx1

Tx2

R x1

R x2
P1.5

BarCodeArea
Fail
Tx O N
R eady

Fault

15 MHz
IN (2)
M VM Load
Lucent
U C U 48v

BN J 24
P1.5

BarCodeArea
FAIL

AC T

15 MHz
M VM Load
Lucent

IN (1)
U C U 48v

BN J 24
P1.5

BarCodeArea

Circuit packs
FAIL

AC T

OUT (2)
M VM Load

15 MHz
Lucent
U C U 48v

BN J 24
P1.5

BarCodeArea
FAIL

AC T
3
4

GREEN = NORMAL
0 12

7 65

RED = FAULT
M VM Load
Lucent

OUT (1)
U C U 48v

15 MHz
9
8

BN J 24
P1.5

BarCodeArea
FAIL

AC T

FAN TRAY POWER


FILTER SHELF
Cable I/O area

Lucent
URC

C
A

B
L1
NVM

RDY

L2
FAIL

L3
L4

FAN TRAY POWER


FAN TRAY

HIOU

Rectifiers Controller Power shelf

Outdoor-specific optional components


The following optional components are specific to the Lucent UMTS Macrocell
Compact Outdoor:
• Fold-down work table attached to the inside of the door
• service outlet for mains voltage
• heat exchanger unit (for ambient temperatures above 46 °C (115 °F) or when
facility equipment is installed inside the cabinet)
• rear duct, highly recommended for thermal management and protection against
cable vandalism
• plinth containing backup batteries.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-19
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Compact Outdoor

Shelves
The Lucent Macrocell Compact Outdoor contains the following shelves:
• Filter shelf
• Hybrid shelf
• Power shelf (optional)
• Connection area.

Shelves and their components


The Lucent Macrocell Compact Outdoor shelves are equipped with the following
components:

Shelf Components
Filter shelf • Filter panels
• Filter Access Card (FAC)
• Circuit Breakers (CBs)
a one unit (1 U) high space, below the filters, is
available to mount customer supplied facilities
equipment.
Hybrid shelf • Amplifier Modules (AMPs)
• splitters and combiners, if required
• Power Distribution Panel (PDP-1)
• circuit packs,
comprising:
– Universal Radio Controller (URC)
– UMTS Channel Units (UCUs)
– Common Timing Unit (CTU)
– Multi-Carrier Radio (MCR)
• Hybrid Input Output Unit (HIOU)
• Oscillator Module (OM)
• Common Power Converter (CPC)
• fan tray
• blanking modules.
• heater (optional)
• PDP-3 (optional)
Power shelf (optional) • Four rectifiers
• power controller
• heater switch.

....................................................................................................................................................................................................................................
3-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
401-382-290R04.03
Issue 1, August 2007




Connection area
Installation options

DIV0
LUCENT-CC XXXXXXXXX

J8
J11
LUCENT-SN XXXXXXXXXXX

J20
J1

RED = FAULT
TEST PULSE
J2-C
J6 J5 J4

J2

GREEN = NORMAL
J3
J7 RF ON TTLNA LNA

J4

J21

TEST CLOCK
J41

J5

J22
0 12
RF ON TTLNA LNA

J6
9 3
8 4 J28
7 65

J7
J31
J26 J25 J24 J22-C

J23
Node B mechanical structure

J8

Receiver preamplifiers
J9

J24
J10

J25
DIV1

J11
J12
DIV0
LUCENT-CC XXXXXXXXX

J13
U C U 48v U C U 48v U C U 48v U C U 48v U C R 2100 U C R 2100 U C R 2100
URC P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 P1.5 CTU J8
BN J 24 BN J 24 BNJ 24 BN J 24 BN J 26 BN J 26 BN J 26 J11
LUCENT-SN XXXXXXXXXXX

J26
Lucent Lucent Lucent

DS1
Lucent Lucent Lucent Lucent Lucent

J14
Lucent
J2-C
J6 J5 J4

J16

J27
J7 RF ON TTLNA LNA

J28
J17
T
D
U
1 FAIL
FAIL J41

J29
RDY
RDY
Tx1 Tx1 Tx1

15MHz IN 15MHz OUT


5V
15V
3.3V
FAIL 8V RF ON TTLNA LNA
T 1.5V
D

J18
NVM Tx O N /O FF Tx O N /O FF Tx O N /O FF J28
U

I2C IN
2
RDY C P C -A C P C -B J31
4 8V 4 8V J26 J25 J24 J22-C
L1 Tx2 Tx2 Tx2

J19
L2 15.00

I2C OUT
MHz
L3 R eady R eady R eady OUT
FAIL FAIL FAIL FAIL
Tx O N Tx O N Tx O N
L4 M VM Load M VM Load M VM Load M VM Load
Fault Fault Fault
AC T AC T ACT AC T
FAIL
Fail Fail Fail DIV1

UTDU
NVM

RDY
A
OM
DIV0
LUCENT-CC XXXXXXXXX
FAIL
15.00 MHz
FLY OUT ø J8
R x1 R x1 R x1 EX J2 J1
J11
LUCENT-SN XXXXXXXXXXX
B

BarCodeArea
BarCodeArea
BarCodeArea

BarCodeArea
BarCodeArea
BarCodeArea
BarCodeArea
J2-C
BIAS-T J6 J5 J4
15.00 MHz FAIL
OUT 1
C RDY

basic plinth
R x2 R x2 R x2
J7 RF ON TTLNA LNA

with optional
OMR
J41
J3 RF ON TTLNA LNA
FAN TRAY FILTER SHELF J7 J28
15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2) J31
J26 J25 J24 J22-C
FAN TRAY POWER FAN TRAY POWER

Outdoor cabinet
DIV1

CB1

CB2

are variously denoted.


AC mains circuit breaker
The connection area contains

Switchable AC mains service outlet


DIV0
LUCENT-CC XXXXXXXXX

J8
J11
LUCENT-SN XXXXXXXXXXX
J20
J1

RED = FAULT
TEST PULSE

J2-C
J6 J5 J4
J2

GREEN = NORMAL
J3

J7 RF ON TTLNA LNA
J4

J21

TEST CLOCK

J41
J5

J22

0 12
RF ON TTLNA LNA
J6

9 3
8 4 J28
7 65
J7

J31
J26 J25 J24 J22-C
J23
J8
J9

J24
J10

J25

DIV1
J11
J12

DIV0
LUCENT-CC XXXXXXXXX
J13

U C U 48v U C U 48v U C U 48v U C U 48v U C R 2100 U C R 2100 U C R 2100


P1.5 P1.5 P1.5 CTU J8

See notice on first page


URC P1.5 P1.5 P1.5 P1.5
BN J 24 BNJ 24 BN J 24 BN J 24 BNJ 26 BN J 26 BNJ 26 J11
LUCENT-SN XXXXXXXXXXX
J26

Lucent Lucent Lucent


DS1

Lucent Lucent Lucent Lucent Lucent


J14

Lucent
J2-C
J6 J5 J4
J16

J27

J7 RF ON TTLNA LNA
J28
J17

T
D
U
1 FAIL
FAIL J41
J29

RDY
RDY
Tx1 Tx1 Tx1
15MHz IN 15MHz OUT

5V
15V
3.3V

Alcatel-Lucent - Proprietary
FAIL 8V RF ON TTLNA LNA
T 1.5V
D
J18

NVM Tx O N /O FF Tx O N /O FF Tx O N /O FF J28
U
I2C IN

2
RDY C P C -A C P C -B J31
4 8V 4 8V J26 J25 J24 J22-C
L1 Tx2 Tx2 Tx2
J19

L2 15.00
I2C OUT

MHz
L3 R eady R eady R eady OUT
FAIL FAIL FAIL FAIL
Tx O N Tx O N Tx O N
L4 M VM Load M VM Load M VM Load M VM Load
Fault Fault Fault
AC T AC T AC T AC T
FAIL
Fail Fail Fail DIV1
UTDU

NVM

RDY
A
OM
DIV0
LUCENT-CC XXXXXXXXX
FAIL
15.00 MHz
FLY OUT ø J8
R x1 R x1 R x1 EX J2 J1
J11
LUCENT-SN XXXXXXXXXXX
B
BarCodeArea
BarCodeArea
BarCodeArea

BarCodeArea
BarCodeArea
BarCodeArea
BarCodeArea

J2-C
BIAS-T J6 J5 J4
15.00 MHz FAIL
OUT 1
C RDY
R x2 R x2 R x2
J7 RF ON TTLNA LNA

with optional
OMR
J41

battery plinth
J3 RF ON TTLNA LNA
FAN TRAY FILTER SHELF J7 J28
15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2) J31
J26 J25 J24 J22-C
FAN TRAY POWER FAN TRAY POWER

Outdoor cabinet
DIV1

CB1

CB2
Installation options for the Lucent Macrocell Compact Outdoor:

battery plinth containing a single string of four backup batteries.


Basic plinth that can be used as a mounting pedestal for the cabinet

Space for power and signalling cables entering the cabinet from below.
View of the installation options for the Lucent Macrocell Compact Outdoor:

Low Noise Amplifiers (LNAs) can be used as receiver preamplifiers in the various
frequency ranges. Depending on frequency ranges and mounting options these LNAs

3-21
Compact Outdoor
Mechanical structure of the Lucent UMTS Macrocell

....................................................................................................................................................................................................................................
Node B mechanical structure Mechanical structure of the Lucent UMTS Macrocell
Compact Outdoor

The DxTMAs are optional Tower Mounted Amplifiers (could also be mounted on a
wall) and provide two independent pre-amplification branches.

....................................................................................................................................................................................................................................
3-22 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Component numbering in the Lucent UMTS Macrocell


Compact Outdoor
...................................................................................................................................................................................................................................

Component numbering full capacity cabinet


Component numbering (schematic diagram, not to scale; the components that are to be
fitted depend on the actual configuration):

Filter Panels
1 2 3

Filter shelf
Facilities
Common I/O panel

FAC

6
5
Amplifier 4
Modules 3
2
1
Hybrid Fan Tray

(B) 2
OM
CPC

(B) 1
(A) 2 (A) 1
Hybrid shelf
2 PDP
CTU 1
3
MCR 2
Cable I/O area

1
4
3
UCU 2
1
2
URC 1

HIOU 1 2

1 2
Rectifiers Power shelf
3 4

Important! The following sections only list those components that are available in
the Lucent Macrocell Compact more than once.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-23
Issue 1, August 2007 See notice on first page
Node B mechanical structure Component numbering in the Lucent UMTS Macrocell
Compact Outdoor

Component numbering in the filter shelf


The components are numbered as follows:

Component Numbering
Filter panels The dual duplexer panels are numbered from left to right,
from 1 to 3.

Component numbering in the hybrid shelf


The components are numbered as follows:

Component Numbering
Amplifier Modules (AMP) From bottom to top, 1 to 6.
Universal Radio From bottom to top, 1 to 2.
Controllers (URCs)
UMTS Channel Units From bottom to top, 1 to 4.
(UCUs)
Multi-Carrier Radios From bottom to the top, 1 to 3.
(MCRs)
Common Timing Units From bottom to top, 1 and 2.
(CTUs)
Common Power Converters From right to left, 1 to 2.
Type A (CPC-A)
Common Power Converters From bottom to top, 1 to 2.
Type B (CPC-B)
Power Distribution Panel The first, PDP-1, is integrated into the Hybrid Shelves’
(PDP) Power Distribution Assembly (PDA).
The optional , PDP-3, can be mounted directly to the
right side of the hybrid shelf when more than three
AMPs are installed.
Power shelf, for AC power top left to bottom right, 1 to 4
applications

....................................................................................................................................................................................................................................
3-24 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Structure of the UMTS Lucent UMTS Modular Cell


Outdoor for +24V

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the mechanical structure diagrams and component numbering of
the Lucent UMTS Modular Cell.

Related information
For more information about the Lucent UMTS Modular Cell, refer to
• Lucent UMTS Modular Cell Outdoor +24 V Technical Description, 401-382-720.

Contents

Mechanical structure of the UMTS Modular Cell Outdoor 3-26


Component numbering in the UMTS Modular Cell Outdoor for +24 V 3-32

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-25
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Mechanical structure of the UMTS Modular Cell Outdoor


...................................................................................................................................................................................................................................

Outside view (cabinet with heat exchanger)


Outside view of the UMTS Modular Cell Outdoor, with solar shields and rear heat
exchanger:

Solar shields

Front View Rear View


Heat Exchanger

Outside view (cabinet with fresh air filter)


Outside view of the UMTS Modular Cell Outdoor, with fresh air filter:

...................................................................................................................................................................................................................................
3-26 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the UMTS Modular Cell Outdoor

Fresh Air
Filter Intake
Front view Rear view

Inside view of a single-band configuration


UMTS Modular Cell Outdoor with door removed (3s1c configuration without Tx
diversity, minimum UCU population, AC powered):

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-27
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the UMTS Modular Cell Outdoor

Filter units

HPDA
EFIM
Filter shelf

Blank

J1 J2 J3 J4 J5 J6

CBs FAC
CB1 CB2

J7
-48VDC

Fan
(rear venting)
Amplifier shelf

PAMs Battery
compartment

CB5-J16
J16

ESD
J1 J2 J3 J4

D C
J13
IN 1
J H
PDP
B
3
F
J5

A
5
E
J6 J7 J8

C
7
F
J14
B

E
9
A
J9

11
D
J10 J11 J12

PDP I-2C nnVDC CB1-J1-J2-J3 CB2-J4-J5-J6 OUT 2 4 6 8 10 12


CB3-J7-J8-J9 CB4-J10-J11-J12

Blank Controller and


interface card GROWTH GROWTH ALARMS
BD

BATTERY GROWTH ALARMS


PWR

ACF

PMN

PMJ
TEMP

FUSE

GREEN = NORMAL

Fan
RED = FAULT

(Front venting)
DC OK

DC OK

DC OK

DC OK
AC OK

AC OK

AC OK

AC OK

UCU48v UCU48v MCR2100 MCR2100 MCR2100


URC CTU

Rectifiers
P1.5 P1.5
BNJ 24 BNJ 24
Digital shelf

Lucent Lucent Lucent Lucent Lucent Lucent Lucent


TECTROL

TECTROL

TECTROL

TECTROL
T Total Power Solutions

T Total Power Solutions

T Total Power Solutions

T Total Power Solutions


MADE IN CANADA

MADE IN CANADA

MADE IN CANADA

MADE IN CANADA
I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A


1413T031600216-2

1413T031600216-2

1413T031600216-2

1413T031600216-2
O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.


P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413
50/60Hz

50/60Hz

50/60Hz

50/60Hz

T
D
U
T

1
Tx1 Tx1 Tx1

FAIL
T
NVM D
U Tx ON/OFF Tx ON/OFF Tx ON/OFF

Circuit packs
2
RDY
L1 Tx2 Tx2 Tx2

L2 15.00
MHz
L3 OUT Ready Ready Ready
FAIL FAIL
Tx ON Tx ON Tx ON
L4 MVM Load MVM Load
DC OK

DC OK

DC OK

DC OK
AC OK

AC OK

AC OK

AC OK

Fault Fault Fault


ACT ACT FAIL

NVM Fail Fail Fail

RDY
A
OM
FAIL
FLY
EX Rx1 Rx1 Rx1

Rectifiers
BIAS-T

C
Rx2 Rx2 Rx2
T TECTROL

T TECTROL

TECTROL

TECTROL
Total Power Solutions

Total Power Solutions

T Total Power Solutions

T Total Power Solutions


MADE IN CANADA

MADE IN CANADA

MADE IN CANADA

MADE IN CANADA
I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A


1413T031600216-2

1413T031600216-2

1413T031600216-2

1413T031600216-2
O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.


P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413
50/60Hz

50/60Hz

50/60Hz

50/60Hz
T

User Alarms E1/T1 E1/T1 Shelf


0-15 16-31 AMP.AI. Config. ID Sel. Ethernet/Select

J9

IOU OM CPCs
J17
15.00 MHz 15.00 MHz
J13 J12 OUT ø OUT ø

J7 J8 J1

AC PDA
J3 J14 J6
J16
J18
15.00 MHz FAIL 15.00 MHz FAIL FAIL
OUT 1 FAIL RDY RDY FAIL FAIL
J4 OUT 1
J5 RDY RDY 5V 5V
RDY RDY
15V 15V
3.3V 3.3V
8V 8V
1.5V 1.5V
JTAG Cab.AI. UDRV 422 Bus

OMA OMQ CPC-A


48V
CPC-A
48V
CPC-B
48V
CPC-B
48V

FAN TRAY FILTER SHELF


15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2)
ESD
DIGITAL SHELF POWER GND
FAN TRAY POWER

Inside view of a dual-band configuration


UMTS Modular Cell Outdoor with door removed, dual-band configuration:

....................................................................................................................................................................................................................................
3-28 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the UMTS Modular Cell Outdoor

J41

J41

J41
LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J2-C

J22-C

J2-C

J22-C

J2-C

J22-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA
Filter units

J24

J24

J24
J4

J4

J4
DIV0

DIV0

DIV0
J25

J25

J25
DIV1

DIV1

DIV1
J5

J5

J5
J26

J26

J26
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8
Filter shelf

HPDA
EFIM
J41

J41

J41
LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX

LUCENT-SN XXXXXXXXXXXX
LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX

LUCENT-CC XXXXXXXXX
J2-C

J22-C

J2-C

J22-C

J2-C

J22-C
RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA

RF ON TTLNA LNA
J24

J24

J24
J4

J4

J4
Filter units

DIV0

DIV0

DIV0
J25

J25

J25
DIV1

DIV1

DIV1
J5

J5

J5
J26

J26

J26
J6

J6

J6
J11

J11

J11
J31

J31

J31
J7

J7

J7
J28

J28

J28
J8

J8

J8
FAC
SEC-B
J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J16 J17 J18 J19

J20 J21 J22 J23 J24 J25 J26 J27 J28 J29
DS1

CBs Blank

GREEN = NORMAL

9
0 12
RED = FAULT

KS-24563 L3 FAN TRAY


AIRFLOW PROFILE SETTING #1
Fan
3 USED WITH

(rear venting)
8 4
7 65 AMPLIFIER, OUTDOOR CABINET
(Application per top-plate label)
Amplifier shelf

1 2 3 4 5 6 7 8 9 10 11 12

RF IN RF IN RF IN RF IN RF IN RF IN

ALM ALM ALM ALM ALM ALM


ACT P2PAM ACT P2PAM ACT P2PAM ACT P2PAM ACT P2PAM ACT P2PAM

Battery
PAMs compartment
RF OUT RF OUT RF OUT RF OUT RF OUT RF OUT

A12 AMPLIFIER SUBRACK

CB5-J16

PDP I-2C nnVDC


J16

ESD
J1

CB1-J1-J2-J3
J2 J3

CB2-J4-J5-J6
J4

D
IN
J
PDP
J13
C
1
H
OUT 2
B
3
F
4
J5

A
5
E
6
J6 J7 J8

C
7
F
8
J14
B

E
9

10
A
11
D
12
J9 J10 J11

CB4-J10-J11-J12
J12

Blank
GROWTH GROWTH ALARMS BATTERY GROWTH ALARMS

BD
PWR

ACF

PMJ
TEMP

FUSE

PMN
GREEN = NORMAL
RED = FAULT

Fan Controller and


(Front venting) interface card
DC OK

DC OK

DC OK

DC OK
AC OK

AC OK

AC OK

AC OK

URC-II
UCU48v UCU48v CTU-II MCR1900 MCR1900 MCR1900 MCR1900 MCR1900 MCR1900

Rectifiers
Digital shelf

P1.5 P1.5 OCXO P1.5 P1.5 P1.5 P1.5 P1.5 P1.5


44WW65 BNJ 24 BNJ 24 BNJ35B
BNJ 50 BNJ 50 BNJ 50 BNJ 50 BNJ 50 BNJ 50
1:1
1:1

Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent Lucent
TECTROL

T TECTROL

TECTROL

T TECTROL
T Total Power Solutions

Total Power Solutions

T Total Power Solutions

Total Power Solutions


MADE IN CANADA

MADE IN CANADA

MADE IN CANADA

MADE IN CANADA
I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A


1413T031600216-2

1413T031600216-2

1413T031600216-2

1413T031600216-2
O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.


P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413
50/60Hz

50/60Hz

50/60Hz

50/60Hz

L-ETH GIG-E
T

TX1 TX1 TX1 TX1 TX1 TX1

TX ON TX ON TX ON TX ON TX ON TX ON

Circuit packs
TX OFF TX OFF TX OFF TX OFF TX OFF TX OFF

U-ETH
TX2 TX2 TX2 TX2 TX2 TX2
GIG-E
TONE TONE TONE TONE TONE TONE
STAT
FAIL FAIL
MVM Load MVM Load
DC OK

DC OK

DC OK

DC OK
AC OK

AC OK

AC OK

AC OK

STAT STAT STAT STAT STAT STAT


TIM 1
ACT ACT TX1-ON TX1-ON TX1-ON TX1-ON TX1-ON TX1-ON

L2 L1 TX2-ON TX2-ON TX2-ON TX2-ON TX2-ON TX2-ON

L4 L3
RC1 RC1 RC1 RC1 RC1 RC1
L6 L5

L8 L7
RX1 RX1 RX1 RX1 RX1 RX1

RC2 RC2 RC2 RC2 RC2 RC2


T1 / E1

RX2 RX2 RX2 RX2 RX2 RX2

URC MCR MCR MCR MCR MCR MCR


Rectifiers
TECTROL

T TECTROL

TECTROL

T TECTROL
T Total Power Solutions

Total Power Solutions

T Total Power Solutions

Total Power Solutions


MADE IN CANADA

MADE IN CANADA

MADE IN CANADA

MADE IN CANADA
I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A

I/P: 100-240 VAC 18A


1413T031600216-2

1413T031600216-2

1413T031600216-2

1413T031600216-2
O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.

O/P: 1350W MAX.


P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413

P/N: TC91S-1413
50/60Hz

50/60Hz

50/60Hz

50/60Hz
T

User Alarms E1/T1 E1/T1 Shelf


0-15 16-31 AMP.AI. Config. ID Sel. Ethernet/Select

J9
J17
15.00 MHz 15.00 MHz
J13 J12 OUT ø OUT ø

J7 J8 J1

IOU J18

JTAG
J16

Cab.AI.
J3

UDRV
J14

J4

422 Bus
J6

J5
15.00 MHz
OUT 1
OM FAIL
RDY
15.00 MHz
OUT 1
FAIL
RDY
FAIL
RDY
5V
3.3V
5V
3.3V
FAIL
RDY

CPCs FAIL
RDY
15V
8V
1.5V
15V
8V
1.5V
FAIL
RDY
AC PDA
OMA OMQ CPC-A
48V
CPC-A
48V
CPC-B
48V
CPC-B
48V

FAN TRAY FILTER SHELF


15 MHz 15 MHz 15 MHz 15 MHz
OUT (1) OUT (2) IN (1) IN (2)
ESD
DIGITAL SHELF POWER GND
FAN TRAY POWER

Outdoor-specific components
The UMTS Modular Cell Outdoor provides the following outdoor-specific components:
• The Enhanced Facilities Interface Module (EFIM) carries the Punch-down
connectors for T1/E1 lines, User Alarms, RS485/422 and User Relays.
• AC-Rectifiers for DC conversion of the AC mains power supply
• The AC Power Distribution Assembly (ACPDA)
distributes the AC power to the
– AC-Rectifiers
– Cabinet Heaters
....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-29
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the UMTS Modular Cell Outdoor

– Battery Heaters
– Convenience outlet.
• The battery compartment contains backup batteries for short-term AC mains failure
coverage and controlled shutdown.
• The High Power Distribution Assembly (HPDA) distributes the DC power from the
AC rectifiers or the internal backup batteries or the optional external batteries to
the shelves inside the cabinet.
Non integrated power option
If DC power supply is available on site, the power module, containing the controller,
the rectifiers and the ACPDA may be omitted. In this case the HPDA is replaced by a
Low Power Distribution Assembly (LPDA), providing fuses for the heat exchanger
fans and the cabinet light.
As no battery backup is necessary when DC power is supplied on site, the battery
compartment is accordingly replaced by a blanking plate.
If additionally AC power supply is available on site, an optional AC service kit
providing an AC mains outlet may be installed.

Shelves
The Modular Cell Outdoor contains the following shelves:
• Filter shelf
• Amplifier shelf
“Note”: The amplifier shelf might be replaced by blanking plates for Multiple
Carrier Power Amplifier (MCPA) configurations.
• Digital shelf.

Shelves and their components


The Modular Cell Outdoor shelves are equipped with the following components:

Shelf Components
Filter shelf The filter shelf contains the following components:
• Filter panels
• Filter Access Card (FAC)
• Circuit Breakers (CB).
• E1/T1 or E3/T3 Secondary Protection (SEC-B)

....................................................................................................................................................................................................................................
3-30 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the UMTS Modular Cell Outdoor

Shelf Components
Amplifier shelf The amplifier shelf contains the following components:
• Power Amplifier Modules (PAM)
• Splitters and combiners, if required
• Power Distribution Panel (PDP)
• Fan tray (configured for amplifier shelf position)
• Blanking modules.
Additional information:
The amplifier shelf might be replaced by blanking plates
for MCPA configurations. In that case the output signals
from the radio units are routed via the hatchplate to the
external amplifiers.
Digital shelf The digital shelf contains the following components:
• Input Output Unit (IOU)
• Oscillator Modules (OM)
• Common Power Converter (CPC)
• Fan tray (configured for digital shelf position)
• Blanking modules
• Circuit packs.
The circuit packs consist of the following units:
• Universal Radio Controller (URC)
• UMTS Channel Units (UCU)
• Common Timing Unit (CTU)
• Multi-Carrier Radio (MCR).

Receiver preamplifiers
Low Noise Amplifiers (LNAs) can be used as receiver preamplifiers in the various
frequency ranges. Depending on frequency ranges and mounting options these LNAs
are variously denoted.
The DxTMAs are optional Tower Mounted Amplifiers (could also be mounted on a
wall) and provide two independent pre-amplification branches.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-31
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Component numbering in the UMTS Modular Cell Outdoor for


+24 V
...................................................................................................................................................................................................................................

Component numbering full capacity cabinet


Component numbering (schematic diagram, not to scale. The components that are to be
fitted depend on the actual configuration):

1 2 3

HPDA
EFIM
Filter shelf

Filter Panels

4 5 6

CB FAC

Fan tray
Amplifier shelf

Amplifier Modules Battery


compartment
1 2 3 4 5 6 7 8 9 10 11 12

PDP

Controller and
interface card

1 2 1 2
Fan tray

Rectifiers
Digital shelf

URC UCU MCR UCU


CTU

3 4 3 4
1 2 3 4 1 2 3 4 5 6 1 2 1 2 3 4 5 6 7 8 9 10 11 12
Auxiliary Primary
shelf shelf
OM CPCA CPCB
IOU
1 2 1 2 3 4 5 6 7 8 AC PDA

Important! The following sections only list components of which there can be
more than one in the Modular Cell Outdoor for +24 V.

...................................................................................................................................................................................................................................
3-32 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Component numbering in the UMTS Modular Cell
Outdoor for +24 V

Component numbering in the filter shelf


The components are numbered as follows:

Component Numbering
Filter panels The filter panels are numbered from left to right, starting
with the upper row, from 1 to 3 and continuing in the
lower row from 4 to 6.

Component numbering in the amplifier shelf


The components are numbered in the following way:

Component Numbering
Amplifier Modules The Amplifier Modules are numbered from left to right,
from 1 to 12.

Component numbering in the digital shelf


The components are numbered as follows:

Component Numbering
URC The Universal Radio Controllers (URC) are numbered
from left to right, from 1 to 4.
UCU The UMTS Channel Units (UCU) are numbered from left
to right, from 1 to 6 (in the left part) and from 7 to 12
(in the right part). The UCUs are pooled resources for 2
groups of 6 UCUs. It is recommended to populate the
UCUs in consecutive order, starting with “1”.
CTU The Common Timing Unit(s) (CTU) are numbered from
left to right, 1 and 2.
MCR The Multi-Carrier Radios (MCR) are numbered from left
to right, from 1 to 6.
OM The Oscillator Module(s) (OM) are numbered from the
left to the right, 1 and 2. Depending on the configuration,
they can be a Rubidium-based (OMR) and/or
quartz-based asynchronous Oscillator Modules (OMA).
CPC The Common Power Converters (CPC) are numbered
from left to right, from 1 to 4 (CPC-A), and from 5 to 8
(CPC-B).

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-33
Issue 1, August 2007 See notice on first page
Node B mechanical structure Component numbering in the UMTS Modular Cell
Outdoor for +24 V

Rectifier numbering
The AC rectifiers are divided into two groups of four. The first group is placed at the
cabinet’s wall, the second group to the left of the first group. Inside the groups the
rectifiers are numbered clockwise from 1 to 4 in the first group and from 5 to 8 in the
second. Numbering starts in the left column, upper row of each group.

....................................................................................................................................................................................................................................
3-34 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Structure of the UMTS Lucent Microcell for +24V

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the mechanical structure diagrams and component numbering of
theLucent UMTS Microcell.

Related information
For more information about the Lucent UMTS Microcell, refer to:
• Lucent UMTS Microcell Technical Description, 401-382-926.

Contents

Mechanical structure of the Lucent UMTS Microcell Outdoor 3-36


Component numbering in the Lucent UMTS Microcell Outdoor 3-41

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-35
Issue 1, August 2007 See notice on first page
Node B mechanical structure

Mechanical structure of the Lucent UMTS Microcell Outdoor


...................................................................................................................................................................................................................................

Outside view
Outside view of the Lucent Microcell Outdoor:

UMTS Microcell (Type M) Battery plinth (optional)

Inside view
View of the Lucent Microcell Outdoor for +24 V with door removed (1s1c
configuration):

...................................................................................................................................................................................................................................
3-36 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the Lucent UMTS Microcell
Outdoor

Fan Tray / Heater assembly


Fan shelf

Fresh air
CPCs filter

Circuit packs PDM


Digital shelf

IOU-1 OMR

Amplifier Amplifier shelf

Rectifier

I/O panel RF Filter Filter- and


Power Power shelf
Cabeling controller

Outdoor specific components


The Lucent Microcell Outdoor for +24 V provides the following outdoor-specific
components:
• 900 W heater on top of cabinet
• Fresh air filter.

Shelves
The Lucent Microcell Outdoor contains the following shelves:
• Fan shelf
• Digital shelf
• Amplifier shelf
• Filter and power shelf.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-37
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the Lucent UMTS Microcell
Outdoor

Shelves and their components


The Lucent Microcell Outdoor shelves are equipped with the following components:

Shelf Components
Fan shelf The fan shelf contains the following components:
• Two fan sections used to cool the digital shelf and
the amplifier.
Digital shelf The digital shelf contains the following components:
• Lucent Microcell Input Output Unit (IOU1C)
• Circuit packs,
comprising the following units:
– Universal Radio Controller (URC)
– UMTS Channel Units (UCU)
– UMTS Multi-Carrier Radio (MCR)
– Common Timing Unit (CTU).
• Common Power Converter (CPC)
• Oscillator Modules (OMs)
• Power Distribution Module (PDM).
Amplifier shelf The amplifier shelf contains the following components:
• Single amplifier module.
Filter and power shelf The filter shelf contains the following components:
• I/O panel
• Dual Duplex Filter with TTLNA support
• Single rectifier module with controller

Installation options
Installation options for the Lucent Microcell Outdoor:
• Pole-mounted (with or without battery plinth)
• Wall-mounted (with or without battery plinth)
• Floor stand-mounted (with or without battery plinth)
• Concrete pad (with battery plinth).
View of the installation options for the Lucent Microcell Outdoor:

....................................................................................................................................................................................................................................
3-38 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure Mechanical structure of the Lucent UMTS Microcell
Outdoor

Cabinet on floor stand Cabinet on battery plinth

Battery plinth
When supplied with AC power, the Lucent Microcell Outdoor can be equipped with a
battery plinth.
The battery plinth contains a water-tight battery compartment for short term AC mains
failure coverage. It can hold up to four 12 V batteries connected in a serial-parellel
configuration to supply +24 volt back-up power to the cabinet in the event of a power
interruption.
View of the optional battery plinth:
Busbar with
battery fuse

Battery clamp

Batteries

Battery plinth (optional)

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-39
Issue 1, August 2007 See notice on first page
Node B mechanical structure Mechanical structure of the Lucent UMTS Microcell
Outdoor

I/O panel
All interface connections to the Lucent Microcell Outdoor enter at the bottom of the
cabinet.
Bottom view of the Lucent Microcell Outdoor:

Bottom view

Door Cabinet with


DC feed or optional Battery Plinth
battery back-up

Earthing points

GPS

RF Antenna

AC feed
E1/T1 feed
User alarms
Spare

Receiver preamplifiers
Low Noise Amplifiers (LNAs) can be used as receiver preamplifiers in the various
frequency ranges. Depending on frequency ranges and mounting options these LNAs
are variously denoted.
The DxTMAs are optional Tower Mounted Amplifiers (could also be mounted on a
wall) and provide two independent pre-amplification branches.

....................................................................................................................................................................................................................................
3-40 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Node B mechanical structure

Component numbering in the Lucent UMTS Microcell Outdoor


...................................................................................................................................................................................................................................

Component numbering full capacity cabinet


Component numbering (schematic diagram, not to scale. The components that are to be
fitted depend on the actual configuration):

Fan tray / heater assembly Fan shelf


1

CPC B
CPC A

Fresh air filter


IOU1C

1 1
MCR

PDM
URC
UCU
UCU

CTU

Digital shelf
Exhaust Duct

Inlet Duct
OM

1 1 1 2 1 1 1 1

Amplifier Amplifier shelf


1

I/O panel Filter- and


RF Filter Rectifier
Cabling Power shelf

1 1

Important! The following sections only list components of which there can be
more than one in the Lucent Microcell Outdoor.

Component numbering in the digital shelf


The components are numbered as follows:

Component Numbering
URC There is only one Universal Radio Controller (URC).
UCU The UMTS Channel Units (UCUs) are numbered from
left to right, from 1 to 2.
MCR There is only one Multi-Carrier Radio (MCR).
CTU There is only one Common Timing Unit (CTU).

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 3-41
Issue 1, August 2007 See notice on first page
Node B mechanical structure Component numbering in the Lucent UMTS Microcell
Outdoor

Component Numbering
CPC There is only one Common Power Converter Type A
(CPC-A), and one Common Power Converter Type B
(CPC-B).
OM There is only one Oscillator Module (OM) . Depending
on the configuration, this can be a Rubidium-based
(OMR) or a quartz-based asynchronous Oscillator Module
(OMA).
PDM There is only one Power Distribution Module (PDM).

Component numbering in the amplifier shelf


The components are numbered as follows:

Component Numbering
Amplifier modules There is only one amplifier module.

Component numbering in the filter shelf


The components are numbered as follows:

Component Numbering
Filter panels There is only one dual duplex filter.

....................................................................................................................................................................................................................................
3-42 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
4 R NC mechanical structure
4

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter contains the mechanical structure diagrams of the RNC.
These diagrams provide the OMC operator with an overview of:
• The RNC hardware that is available
• The location of the hardware within the RNC cabinet
• The basic functions of the RNC hardware.

Related information
For more information about the RNC mechanical structure, refer to:
• Lucent RNC Technical Description, 401-382-320

Contents

UMTS RNC mechanical description 4-2


cPSB chassis and components 4-6
cPSB chassis configuration 4-8

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-1
Issue 1, August 2007 See notice on first page
RNC mechanical structure

UMTS RNC mechanical description


...................................................................................................................................................................................................................................

Overview
This topic provides a brief description of the Radio Network Controller (RNC)
components.

RNC main components


The main components are as follows:
• UMTS RNC cabinet
• Frame Interface Panel (FIP)
• Power Distribution Shelf (PDS)
• Compact PCI Packet Switched Backplane (cPSB) chassis
• Terminal server (optional)

RNC inside view


The following diagram displays the inside of the RNC as viewed from the front:

...................................................................................................................................................................................................................................
4-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
RNC mechanical structure UMTS RNC mechanical description

FIP X X

assembly -48VA RTNA -48VB RTNB

X X X X X X

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Power X X X
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
X X X

distribution Lucent
O
O

Lucent

shelf O
O
INPUT POWER OK

O
O
50 A MAX 50 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 30 A MAX
O
O

O
O
O
O
INPUT POWER OK

O
O
50 A MAX 50 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 40 A MAX 30 A MAX
REVERSE POLARITY REVERSE POLARITY
O
O

CB 1 CB 2 CB 3 CB 4 CB 5 CB 6 CB 7 CB 8 CB 9 CB 1 CB 2 CB 3 CB 4 CB 5 CB 6 CB 7 CB 8 CB 9

ECBU-A ECBU-B

Blank
panel
Alarm
board

Fiber Management O
O
X

! !! !!! O
X O
X O
X O
X O
X O
X O
X O
X O
X O
X
Fan
Unit (FMU) Trays
CONSOLE CONSOLE

O
O
o
O
O
o
o o o o

Console
Console

o o o o
O
o o o o
o
oo o o o o
oo

O O
oo
oo
oo CPC6601 O O CPC6601
oo
oo 10/100/1000M 10/100/1000M
O
P P P P P P P P P P
P P P M M M M M M M M P P P
M M M

GbE 1
GbE 1

M M M C C C C C C C C M M

20X
20X

C C C
C C C 2 2 2 2 2 2 2 2 C C
2 2 B
B B B B B

21X
21X

GbE 2
GbE 2

22X
22X

PRB 1 PRB 2 PRB 1 PRB 2

23X
23X

O O O O

Mezzanine 2
Mezzanine 2

P P P P P P P P P P
OOOO M M M M M M M M OOOO

A B
M M
A B

P P P P P P
O M M M C C C C C C C C C C M M M
OOOO
X
OOOO C C C 1 1 1 1 1 1 1 1 1 1 C C C
O OOOO A A A A A A OOOO
OOOO OOOO

Upper
X

! !! !!! OOOO OOOO


OOOO OOOO
OOOO OOOO
OOOO OOOO
CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM
OOOO RS O
R R R R R R R R R R
OOOO
COM COM COM O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT COM COM COM
O
OOOO OOOO
o
oo
oo
oo
oo
OOOO
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2
R/
U1 OOE/
U2 OOOO
OOOO OOOO
oo
oo
E E E E E E E E

cPSB
E E

Mezzanine 1
Mezzanine 1

oo

O T T T T T T T T T T
CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650

A B
A B

MGMT (MDI) H H H H H H H H MGMT (MDI)


H H

Link
1 1 1 1 1 1 1 1
Link

O ABORT ABORT ABORT 1 1 ABORT ABORT ABORT O


S S S S S S S S S S
O O O O O O O O O O O O O O O O O O O O
E OO E OO E OO E OO E OO E OO E OO E OO

Speed
E OO E OO
Speed

RESET RESET RESET O


O
O
O
O
O
O
O
O
O
O
O
O
O
O
O O O RESET RESET RESET
O R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O R O OO
O
O
O
O
R O OO
O
O
O
O
O
ALARM/ ALARM/ ALARM/ I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O I OO O O
O ALARM/ ALARM/ ALARM/ 10/100M
10/100M O O O O O O O O O O O O O O O O O
O
O O
O
O
USER USER USER A O O
A O O
A O O
A O O
A O O
A O O
A O O
A O O A O A O USER USER USER
O O
O Reset L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 O Reset
READY READY READY READY READY READY
CompactPCI TM
O O O O O O O O O O CompactPCI TM
R

chassis
R
HOT HOT HOT HOT HOT HOT
+ O HOT SWAP
SWAP SWAP SWAP HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS SWAP SWAP SWAP
HOT SWAP
O
O
X O
X O
X O
X O
X O
X O
X O
X O
X O
X

Cable Management
Unit (CMU)
This is a much longer Label This is a much longer Label This is a much longer Label This is a much longer Label This is a much longer Label
taking up 2 lines taking up 2 lines taking up 2 lines taking up 2 lines taking up 2 lines

Label Label Label Label Label Label Label Label Label Label

Terminal server
(shown without MRV
Communications Inc.
IR Series In-Reach

front cover)

FMU
O
O
X

! !! !!! O O O O O O O O O O
Fan
Trays
X X X X X X X X X X

CONSOLE CONSOLE

O
O
o
O
O
o
o o o o
Console
Console

o o o o
O
o o o o
o
oo o o o o
oo

O O
oo
oo
oo CPC6601 O O CPC6601
oo
oo 10/100/1000M 10/100/1000M
O
P P P P P P P P P P
P P P M M M M M M M M P P P
M M M
GbE 1
GbE 1

M M M C C C C C C C C M M
20X
20X

C C C
C C C 2 2 2 2 2 2 2 2 C C
2 2 B
B B B B B
21X
21X

GbE 2
GbE 2

22X
22X

PRB 1 PRB 2 PRB 1 PRB 2

+
23X
23X

O O O O
Mezzanine 2
Mezzanine 2

P P P P P P P P P P
OOOO M M M M M M M M OOOO
A B

M M
A B

P P P P P P
O M M M C C C C C C C C C C M M M
OOOO
X
OOOO C C C 1 1 1 1 1 1 1 1 1 1 C C C

Lower
O OOOO A A A A A A OOOO
X OOOO OOOO
! !! !!! OOOO OOOO
OOOO OOOO
OOOO OOOO
OOOO OOOO
CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM
OOOO RS O
R R R R R R R R R R
OOOO
COM COM COM O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT COM COM COM
O
OOOO OOOO
R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/ R/
OOE/

cPSB
o
oo
oo
oo
oo
OOOO U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 OOOO
OOOO OOOO
oo
oo
E E E E E E E E E E
Mezzanine 1
Mezzanine 1

oo

O T T T T T T T T T T
CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650
A B
A B

MGMT (MDI) H H H H H H H H MGMT (MDI)


H H
Link

1 1 1 1 1 1 1 1
Link

O ABORT ABORT ABORT 1 1 ABORT ABORT ABORT O


S S S S S S S S S S
O O O O O O O O O O O O O O O O O O O O
E OO E OO E OO E OO E OO E OO E OO E OO
Speed

E OO E OO
Speed

RESET RESET RESET O


O
O
O
O
O
O
O
O
O
O
O
O
O
O
O O O RESET RESET RESET
O R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O R O OO
O
O
O
O
R O OO
O
O
O
O
O
ALARM/ ALARM/ ALARM/ I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O I OO O O
O ALARM/ ALARM/ ALARM/ 10/100M
10/100M O O O O O O O O O O O O O O O O O
O
O O
O
O
A O A O A O A O A O A O A O A O A O A O USER

chassis
USER USER USER O O O O O O O O O O USER USER
O Reset L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 O Reset
READY READY READY READY READY READY
CompactPCI TM
R
HOT HOT HOT
O O O O O O O O O O HOT HOT HOT
CompactPCI TM
R

+ O HOT SWAP
SWAP SWAP SWAP HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS SWAP SWAP SWAP
HOT SWAP
O
O
X O
X O
X O
X O
X O
X O
X O
X O
X O
X

CMU
This is a much longer Label This is a much longer Label This is a much longer Label This is a much longer Label This is a much longer Label
taking up 2 lines taking up 2 lines taking up 2 lines taking up 2 lines taking up 2 lines

Label Label Label Label Label Label Label Label Label Label

Blank
panel

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-3
Issue 1, August 2007 See notice on first page
RNC mechanical structure UMTS RNC mechanical description

Cabinet
The cabinet provides support for:
• Installation in both NAR and ETSI central offices
• Underfloor cable entry
• Raised floor installation
• Minimal requirement for floor space
• Cable entry from overhead cable racks
• Simplicity of maintenance through its straightforward layout. Maintenance is
typically performed from the front of the cabinet.

Frame Interface Panel


The Frame Interface Panel (FIP) provides:
• A common connector location for terminating all cables (with the exception of fiber
optic cables) that enter and exit the cabinet
• Reusable internal cable restraining hardware
• EMC cable terminations (both for internal and external cable shielding)
• A simplified external cabinet cabling maintenance interface

Power Distribution Shelf


The Power Distribution Shelf (PDS) includes:
• Two individually serviceable Enhanced Circuit Breaker Units (ECBU) used to
distribute power to components within the cabinet
• An alarm board that acts as an alarm collection and dissemination point for
cabinet-level alarm information

cPSB chassis
The cPSB chassis and its installed components are the primary call processing element
of the cabinet. The cPSB chassis has 21 slots for a combination of node cards, alarm
cards, and Ethernet ® switch cards. Each cabinet has two cPSB chassis.
The following types of cards are used:
• Alarm Cards (AC), also known as Chassis Management Modules (CMM)
• Gateway Intelligent Carrier Cards (GICC)
• Common Intelligent Carrier Cards (CICC)
• Ethernet Switch Cards (ESC)
• Solaris Blades (SB), also known as (FMS) blades

...................................................................................................................................................................................................................................
4-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
RNC mechanical structure UMTS RNC mechanical description

Terminal server (optional)


The cabinet can use a terminal server. The terminal server enables remote low-level
command access for maintenance operations. Remote network access to the serial and
console ports of frame components is also provided.

External auxiliary equipment


An optional External Alarm Box (EAB) is an item of external equipment, not part of
the RNC. The EAB is used to collect and report environmental and other fault
indications to the RNC OA&M application. An Ethernet port is provided on the RNC
FIP to support this interface.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-5
Issue 1, August 2007 See notice on first page
RNC mechanical structure

cPSB chassis and components


...................................................................................................................................................................................................................................

Overview
This topic describes the Compact PCI Packet Switched Backplane (cPSB) chassis,
which may also be referred to as the cPSB shelf, its component parts and their
functions.

cPSB chassis
The cPSB chassis and its installed components are the primary element of the FBP
cabinet. Up to twocPSB chassis can be contained in an FBP cabinet.
The cPSB chassis is PICMg2.16-compliant and is the foundation of the cPSB shelf and
components. The cPSB chassis includes the backplane, power, and cooling. It is a
full-height (12U high) chassis that provides slots for the remaining subcomponents.
The components in each PICMg2.16-compliant cPSB chassis include:
• Alarm Cards (AC): 2 per chassis
• Ethernet Switch Cards (ESC): 2 per chassis
• Depending on the configuration, up to 18 processing cards per chassis including
Common Intelligent Carrier Cards (CICCs), Gateway Common Carrier Cards
(GICCs) and Solaris Blades (SBs)
• Power supply units
• Fan trays
• Blank panels for unused slots.

Alarm Cards
The chassis Alarm Cards (ACs) provide reliability management for the blades. Two
alarm cards are used in each cPSB shelf. The alarm card follows the standard PICMG
2.16 and IPMI specifications. Software in the alarm cards implements low-level chassis
hardware management and provides alarm information to the application.
The alarm cards obtain feed voltage status directly from the power supplies. This
enables the alarm cards to send alarm information via Simple Network Management
Protocol (SNMP) to a system manager.

Ethernet ® Switch Cards


The Ethernet ® Switch Cards (ESC) provide internal and external Ethernet connectivity.
Two ESCs are used in each cPSB shelf. The gigabit Ethernet switch operates in a
standard PICMG 2.16 extended fabric slot. The ESC provides a total of 24 switched

...................................................................................................................................................................................................................................
4-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
RNC mechanical structure cPSB chassis and components

Gigabit Ethernet ports. Four of the switched ports are available for interfacing with
other switched ports in the cabinet or with an external network. 20 ports are available
within the backplane to connect to other cards in the chassis.

Solaris ® Blades
A Solaris Blade (SB) consists of a Sun ™ Sparc ® processor and provides call processing
and OA&M functions.
The SPARC processor core communicates with the packet switched backplane directly
through two 10/100 Base -TX Ethernet interfaces. The Solaris ® Blade is a PICMG ®
2.16 cPSB card implementing a complete Solaris system including processor, memory
and disk subsystem. Two PCI Mezzanine Card (PMC) slots are available for individual
application needs.
The contents of the PCI mezzanine cards in the Solaris Blade varies:
• Slot A is available for additional I/O needs (for example, Ethernet interface)
• Slot B is reserved for the on-board disk drive.

Common Intelligent Carrier Cards


The Common Intelligent Carrier Cards (CICC) provide signalling processing and
general purpose processing power for software modules that are computer-intensive.
The UMTS RNC CICCs have three independent PowerPC processors, each running the
CP, SP and TP applications.

Gateway Common Carrier Cards


The Gateway Intelligent Carrier Cards (GICC) blade provide network routing between
traffic on ATM optical links and the Gigabit ports on the ESC for a fast, flexible data
path processing for a number of telecommunications protocols.

Power supply units


The bottom of each cPSB chassis contains two power trays. Each tray has its own
backplane that provides slots for up to four power supplies. Each power supply is a
field replaceable unit.

Fan trays
The top of each cPSB chassis contains three fan trays, each containing three fans, a
control board and a status LED. This combination of fan trays provides cooling for the
entire shelf. Each fan is a Field Replaceable Unit (FRU).

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-7
Issue 1, August 2007 See notice on first page
RNC mechanical structure

cPSB chassis configuration


...................................................................................................................................................................................................................................

cPSB chassis
The cPSB chassis contains:
• Fan units
• Circuit packs
• Power supply units
• Blanking panels

Power supply units


The power supply units are proprietary field replacement units.

Fan units
The fan units are proprietary field replacement units.

Circuit packs
The following types of circuit packs are used:
• Alarm Card (AC). Also known as a Chassis Management Module (CMM)
• Gateway Intelligent Carrier Card (GICC)
• Common Intelligent Carrier Card (CICC)
• Ethernet Switch Card (ESC)
• Solaris Blade (SB). Also known asFMS Blade

Blanking panels
Blanking panels cover all unused circuit pack slots. This ensures correct airflow
through the cPSB chassis.

Configurations supported
The cPSB chassis supports the following circuit pack configurations for the UMTS
RNC:
• A-12-10 configuration
• A-12-20 configuration

cPSB chassis
The following diagram shows a front view of a UMTS cPSB chassis with circuit
packs. It is the same for both upper and lower chassis.

...................................................................................................................................................................................................................................
4-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
RNC mechanical structure cPSB chassis configuration

Fan units

GICC

ESC

O
X

O
X

! !! !!! O
X O
X O
X O
X O
X O
X O
X O
X O
X O
X

CONSOLE CONSOLE

O
O
o
O
O
o
o o o o

Console
Console

o o o o
O
o o o o
o
o o o o

Alarm
oo
oo
oo
oo
oo
oo
CPC6601 O
O O
O CPC6601
oo 10/100/1000M 10/100/1000M
P P P P P P P P P P

card 1
O
P P P M M M M M M M M M M P P P

GbE 1
GbE 1

M M M M M M

20X
20X

C C C C C C C C C C
C C C 2 2 2 2 2 2 2 2 C C C
2 2
B B B B B B

21X
21X

GbE 2
GbE 2

22X
22X

PRB 1 PRB 2 PRB 1 PRB 2

23X
+
23X

O O O O

Mezzanine 2
Mezzanine 2

P P P P P P P P P P

A B
OOOO
A B

OOOO P P P M M M M M M M M M M P P P
O
X M M M C C C C C C C C C C M M M
OOOO C C C 1 1 1 1 1 1 1 1 1 1 C C C
OOOO
O OOOO A A A A A A OOOO
X OOOO OOOO
! !! !!! OOOO OOOO
OOOO OOOO
OOOO OOOO
OOOO OOOO
CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM CompactPCI TM
OOOO RS O
R R R R R R R R R R
OOOO
COM COM COM O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT RS O O ABT COM COM COM
O
OOOO R/ R/ R/ R/ R/ R/ R/ R/ OOOO
o
oo
oo
OOOO OOE/ OOE/ OOE/ OOE/ OOE/ OOE/ OOE/ OOE/ R/
OOE/ R/
OOE/ OOOO
Alarm
oo
oo
U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2
oo
oo
OOOO OOOO

Mezzanine 1
E E E E E E E E
Mezzanine 1

oo
E E
O T T T T T T T T T T

A B
A B

CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 CP2300S-650 MGMT (MDI)

card 2
MGMT (MDI) H H H H H H H H H H

Link
Link

O 1 1 1 1 1 1 1 1 1 1 O
ABORT ABORT ABORT ABORT ABORT ABORT
S S S S S S S S S S
O O O O O O O O O O O O O O O O O O O O

Speed
E OO E OO E OO E OO E OO E OO E OO E OO
Speed

RESET RESET RESET O


O
O
O
O
O
O
O
O
O
O
O
O
O
O
O E OO O
O E OO O
O RESET RESET RESET
O R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O
R O OO O
O
O R O OO O
O
O
R O OO O
O
O
O
ALARM/ ALARM/ ALARM/ I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O I OO O O
O
O
ALARM/ ALARM/ ALARM/ 10/100M
10/100M O O O O O O O O O O O O O O O O O O O O
USER USER USER A O O
A O O
A O O
A O O
A O O
A O O
A O O
A O O A O A O USER USER USER
O O
O Reset L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 L 1 2 O Reset
READY READY READY READY READY READY
CompactPCI TM CompactPCI TM
R
HOT SWAP HOT HOT HOT
O O O O O O O O O O HOT HOT HOT HOT SWAP
R

+ O SWAP SWAP SWAP HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS HS OOSYS SWAP SWAP SWAP O
O
X O
X O
X O
X O
X O
X O
X O
X O
X O
X

Solaris
Blades

CICC

ESD This is a much longer Label


taking up 2 lines
This is a much longer Label
taking up 2 lines
This is a much longer Label
taking up 2 lines
This is a much longer Label
taking up 2 lines
This is a much longer Label
taking up 2 lines

ground
jack
grille/filter
Label Label Label Label Label Label

Power
Label Label Label Label

supply
units

A-12-10 UMTS chassis configuration


The circuit packs must be located in specific slots, as indicated in the following figure:

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-9
Issue 1, August 2007 See notice on first page
RNC mechanical structure cPSB chassis configuration

SB1-06 (fms09)
SB1-04 (fms05)

SB1-05 (fms01)
CMM1-1

CICC1-09

CICC1-10

CICC1-11

CICC1-12

CICC1-13

GICC1-20
GICC1-3

BLANK

BLANK

BLANK

BLANK

BLANK

SB1-18

SB1-19

ESC1-21
SB1-17
ESC1-2
Card
Chassis

CMM1-2
1

Slot 2 3 4 6 7 8 9 10 11 12 14 15 16 18 20
1 5 13 17 19 21
position

SB2-04 (fms06)

SB2-05 (fms02)

BLANK(fms10)
CMM2-1

CICC2-11

CICC2-12

CICC2-13
CICC2-09

CICC2-10

GICC2-20
BLANK

BLANK

BLANK
GICC2-3

BLANK
BLANK

SB2-17

SB2-18

SB2-19

ESC2-21
ESC2-2

SB2-06
Card
CMM2-2

Chassis
2

Slot
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
position

Legend:

AC Alarm Card – pre-configured to occupy slot 1


ESC Ethernet Switch Cards – must always occupy slots 2 and 21
CICC Common Intelligent Carrier Cards – must always occupy slots
9 - 13
GICC Gateway Intelligent Carrier Cards – must always occupy slots 3
and 20
SB Solaris Blades – must always occupy slots 4 - 6 and 17 - 19

A-12-20 UMTS chassis configuration


The circuit packs must be located in specific slots, as indicated in the following figure:

...................................................................................................................................................................................................................................
4-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
RNC mechanical structure cPSB chassis configuration

CMM1-1

SB1-04 (fms05)

SB1-05 (fms01)

SB1-06 (fms09)

SB1-19 (fms03)
SB1-17 (fms11)

SB1-18 (fms07)
CICC1-7

CICC1-8

CICC1-9

CICC1-10

CICC1-11

CICC1-12

CICC1-13

CICC1-14

CICC1-15

CICC1-16

GICC1-20
GICC1-03

ESC1-21
ESC1-02
Card
Chassis

CMM1-2
1

Slot 2 3 4 6 7 8 9 10 11 12 14 15 16 18 20
1 5 13 17 19 21
position
CMM2-1

SB2-19 (fms04)
SB2-04 (fms06)

SB2-05 (fms02)

SB2-06 (fms10)

SB2-17 (fms12)

SB2-18 (fms08)
CICC2-11

CICC2-12

CICC2-13

CICC2-14

CICC2-15

CICC2-16
CICC2-7

CICC2-8

CICC2-9

CICC2-10

GICC2-20
GICC2-03

ESC2-21
ESC2-02

Card
CMM2-2

Chassis
2

Slot
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
position

Legend:

AC Alarm Card – pre-configured to occupy slot 1


ESC Ethernet Switch Cards – must always occupy slots 2 and 21
CICC Common Intelligent Carrier Cards – must always occupy slots
7 - 16
GICC Gateway Intelligent Carrier Cards – must always occupy slots 3
and 20
SB Solaris Blades – must always occupy slots 4 - 6 and 17 - 19

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 4-11
Issue 1, August 2007 See notice on first page
Part III: Performing OAM&P on the
UTRAN

Overview
...................................................................................................................................................................................................................................

Purpose
This documentation part includes the descriptive and procedural information that an
OMC operator basically needs to know to perform OAM&P tasks on the UTRAN.

Reference
For more information about performing OAM&P tasks on the UTRAN, refer to:
• UMTS Lucent OMC-UPS Operations, Administration, Maintenance, and
Provisioning, 401-380-022
• UMTS Lucent Managed Object Descriptions, 401-380-071

Contents

Chapter 5, UTRAN tools 5-1


Chapter 6, Radio frequencies 6-1
Chapter 7, E1T1 growth 7-1
Chapter 8, SSH and Telnet connections 8-1
Chapter 9, Recommended OMC filters 9-1
Chapter 10, The UTRAN Managed Information Model (MIM) 10-1

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary III-1
Issue 1, August 2007 See notice on first page
5 U TRAN tools
5

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter describes the tools and equipment that can be used to :
• Perform maintenance on the UTRAN
• Check the UTRAN performance.

Contents

Maintenance terminals 5-2


Orthogonal Channel Noise Simulator 5-4
RF trace 5-6
HSDPA Orthogonal Channel Noise Simulator 5-7

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 5-1
Issue 1, August 2007 See notice on first page
UTRAN tools

Maintenance terminals
...................................................................................................................................................................................................................................

Introduction
Maintenance terminals provide the maintenance management interface for the UTRAN.
Types of maintenance terminals are:
• RNC Local Maintenance Terminal (LMT)
• Node B Remote Maintenance Terminal (RMT).
• Node B Local Maintenance Terminal (LMT)

RNC LMT
The RNC LMT provides telnet access to a command-line interface that is used to
perform administration, diagnosis, and maintenance of the RNC equipment. Connection
to the RNC is via the RNC LAN or directly over the RS-232 serial port.

Node B RMT
The Node B RMT application allows maintenance tasks to be performed on a Node B
without a physical connection to a wireless network. The Node B RMT can be used
for installation and maintenance of Node B cells.

Node B LMT
The Node B LMT provides access to the element management functions used to
perform administration, diagnosis, and maintenance of the Node B equipment.
Connection to the Node B is via the Ethernet port on the Node B.
Event message
The Node B sends an event message to the OMC to indicate that a Node B LMT has
gained control over the Node B. In this case, the Node B maintains the registration
with both the OMC and the Node B LMT. Any autonomous events and alarms from
the Node B, which are generated by the Node B, are sent to both the OMC and the
Node B LMT.
Events resulting from operations such as create or delete from the OMC will be sent to
the Node B LMT. Events resulting from operations such as create or delete from the
Node B LMT will be sent to the OMC.
When both the OMC and Node B LMT manage the same Node B in parallel, the LMT
takes precedence. In this case, the Node B LMT has read/write privileges and the
OMC has read-only privileges. The Node B automatically synchronizes its data with
the OMC through events.

...................................................................................................................................................................................................................................
5-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN tools Maintenance terminals

Functions of LMTs and RMTs


The principal functions of RMTs and LMTs are to:
• Perform installation and commissioning tasks
• Read and write inventory data
• Create and restore backups
• Fault management
• Software administration
• Tests and diagnostics (reset, shutdown, etc.)
• Trace/debug functions.

Main Maintenance Terminal


The Integrated Maintenance System for UTRAN (FIMS-UT) is a laptop or desktop PC
that is equipped with software to integrate different maintenance tools on one PC
platform. The term Main Maintenance Terminal (MMT) is also used instead of
FIMS-UT. The RNC can physically connect one MMT at a time.
Applications that are combined on the MMT:
• OMC Remote Access for installation scripts and routine maintenance activities on
each NE
• RNC LMT that is used to diagnose and maintain the RNC
• Mobility Server (FMS) interface for access to the FMS resources
• Node B RMT that is used for local diagnosis and maintenance of Node B BTSs
• Node B LMT that is used to administer, diagnose and maintain the Node B.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 5-3
Issue 1, August 2007 See notice on first page
UTRAN tools

Orthogonal Channel Noise Simulator


...................................................................................................................................................................................................................................

Overview
The Orthogonal Channel Noise Simulator (OCNS) is a tool that simulates voice or data
traffic on the forward link or downlink from the Node B to the UE within a cell or
cluster of cells. The OCNS runs on the Node B, hence only OCNS setup data is sent
over the Iub interface and not the noise itself.

Test call
On request of a technician, OCNS noise is generated to cause interference for a special
test call. This is particularly necessary when the network is first installed and when
cluster testing and complete system testing are required.

Noise model
Noise models that are supported by the OCNS are:
• Voice
• Data.
The generated noise pattern can be defined by parameters to simulate the interference
noise that is generated by real live traffic.

OCNS voice model


The OCNS voice simulation model and parameters for a single user:
burst on time

burst off time

Where:
• burst on time represents voice activity by the simulated user
• burst off time represents no voice activity by the simulated user.

OCNS data model


The OCNS data simulation model and parameters for a single user:

...................................................................................................................................................................................................................................
5-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN tools Orthogonal Channel Noise Simulator

burst cluster burst on time

burst off time think time

Where:
• burst on time represents data activity by the simulated user
• burst off time represents no data activity by the simulated user
• burst cluster represents the total on and off burst time
• think time represents the processing time for the tool.

Power variation
Power variation can be used to vary the power of each frame to simulate power
control. When power variation is switched off, each frame will be sent with a constant
power level.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 5-5
Issue 1, August 2007 See notice on first page
UTRAN tools

RF trace
...................................................................................................................................................................................................................................

Introduction
The RF trace capability is a service which allows the operator to gather radio related
information associated with a predefined UE.
The information that is collected is can be used by the network operator to:
• Check the network performance
• Localize faults
• Optimize the network.

Performed in RNC
The RF trace functionality within the RNC is performed by the collection of signaling
messages on the Uu, Iub and Iu interfaces.

Collected data
For each RF trace, data is collected from the following sources:
• UE
• Node B
• RNC.

Trace data storage


After receiving the command to start an RF trace, the RNC creates a trace-data file.
The file name has the following format IMSI_timestamp_rncid. It consistes of the IMSI
of the UE, the time upon which the trace was initiated and the RNC identity.

Number of RF traces
The maximum number of traces that can be performed are:
• One RF trace per UE
• 10 RF traces per RNC.

Viewing trace data


The trace-data files are in XML format and can be viewed with a normal text editor on
the screen at the RNC LMT or the OMC (after uploading the file from the RNC). The
trace-data files can be archived for analysis and processing by data-analysis tools.

...................................................................................................................................................................................................................................
5-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
UTRAN tools

HSDPA Orthogonal Channel Noise Simulator


...................................................................................................................................................................................................................................

Overview
The High Speed Downlink Packet Access (HSDPA) Orthogonal Channel Noise
Simulator (OCNS) is a tool that simulates HSDPA traffic on the forward link or
downlink from the Node B to the UE within a cell or cluster of cells.

Test call
On request of a technician, HSDPA-OCNS traffic is generated to cause interference for
a special test call. This is particularly necessary when the network is first installed and
when cluster testing and complete system testing are required.

HSDPA-OCNS data model


The HSDPA-OCNS data simulation model and parameters for a single user:
burst cluster burst on time

burst off time think time

Where:
• burst on time represents data activity by the simulated user
• burst off time represents no data activity by the simulated user
• burst cluster represents the total on and off burst time
• think time represents the processing time for the tool.

Power variation
Power variation can be used to vary the power of each frame to simulate power
control. When power variation is switched off, each frame will be sent with a constant
power level.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 5-7
Issue 1, August 2007 See notice on first page
6 R adio frequencies
6

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides procedures for:
• modifying the frequency for Node B cells, and
• adding new frequencies on the RNC.

Contents

Modifying frequency for Node B cells 6-2


Verify RNC configured frequency 6-3
Modify Node B frequency - CLI 6-5
Modify Node B frequency - GUI 6-8
New frequency configuration 6-11
Preliminary information 6-12
Add a new frequency 6-14
Check RNC configured frequency 6-16
RNC Reset 6-18
RNCTRACE Reset 6-20

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-1
Issue 1, August 2007 See notice on first page
Radio frequencies

Modifying frequency for Node B cells

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the procedures that should be performed to modify the Node B
frequency.

Contents

Verify RNC configured frequency 6-3


Modify Node B frequency - CLI 6-5
Modify Node B frequency - GUI 6-8

...................................................................................................................................................................................................................................
6-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies

Verify RNC configured frequency


...................................................................................................................................................................................................................................

Purpose
This procedure should be followed to verify that the required frequency for the Node B
is configured on the RNC.

Radio Frequency
The UTRAN frequency is the licensed frequency in which the RNS is allowed to
operate in for a specific market.

Before you begin


Ensure that you have appropriate CM privileges.

Procedure
Perform the following steps to verify that the required frequency is available:
...................................................................................................................................................................................................

1 At the Network Manager HM view, select the RNC object for which you want to
verify the radio frequency.
...................................................................................................................................................................................................

2 Go to the View menu, select Show on tree.


...................................................................................................................................................................................................

3 Double click on the RNC object in the hierarchy tree.


Result: The LRNC detailed view appears.
...................................................................................................................................................................................................

4 In the LRNC detailed view, select the LRNC tab.


Result: The LRNC tab appears.
...................................................................................................................................................................................................

5 Verify in the frequency table, if the specified frequency for the UTRAN is listed. The
frequencies are listed as the frequencyBand and frequency channel number.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-3
Issue 1, August 2007 See notice on first page
Radio frequencies Verify RNC configured frequency

...................................................................................................................................................................................................

6 Verify if the frequency to be assigned is defined.

If the frequency is defined... then...


Yes You can change the Node B frequency.
Go to one of the following:
• CLI - “Modify Node B frequency -
CLI” (p. 6-5)
• GUI - “Modify Node B frequency -
GUI” (p. 6-8)
Note: Using the CLI to modify
frequencies takes less time than using the
GUI.
No See “New frequency configuration”
(p. 6-11) to add a new frequency to an
RNC.

...................................................................................................................................................................................................

7 Click Finish.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies

Modify Node B frequency - CLI


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to modify the frequency used in the downlink
direction for a Node B cell.
The OMC CLI is used in this procedure.
Important! This procedure is useful when you update a few Node Bs manually. If
the frequency of all Node Bs in a market need to be changed, then a script which
makes repetitive use of the modifycell-lcell command is recommended.

Commands
There are two commands:
• Shutdown - In this scenario, the LCell object is shutdown gracefully. Existing calls
within the cell are allowed to complete before the object is shutdown. See “Modify
Node B frequency - without locking cell” (p. 6-6).
• Lock - In this scenario, the LCell object is immediately shutdown. Existing calls
within the cell are not allowed to complete before the object is shutdown. See
“Modify Node B frequency - locking cell” (p. 6-6).

Scripts
A script can be created to change the frequency for multiple cells on multiple Node Bs.
The script will need to repeat the modifycell-lcell command multiple times to
change the frequency for the required cells.

Reference
For more information on the modifycell-lcell command, refer to:
• Command Line Interface, 401-380-072.

Before you begin


Ensure that:
• you have appropriate CM privileges
• the required frequency is available. See “Verify RNC configured frequency”
(p. 6-3).
Important! This command is service affecting as the LCell object will be
shutdown by the modifycell-lcell command.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-5
Issue 1, August 2007 See notice on first page
Radio frequencies Modify Node B frequency - CLI

Modify Node B frequency - without locking cell


This format of the command may be more time consuming as it waits for existing calls
to complete before shutting down the object.
Perform the following steps to modify the frequency of the cell:
...................................................................................................................................................................................................

1 Run the following command at the command line:


modifycell-lcell:name=<full distinguished name of cell>,LCELLATTRS_
URAFCNND=<new value>;

Example:
modifycell-lcell:name=″LRNC=41,LNodeB=10,LCell=3″,LCELLATTRS_UARFCNND=
4357;

E...................................................................................................................................................................................................
ND OF STEPS

Modify Node B frequency - locking cell


This format of the command is less time consuming as it does not wait for existing
calls to complete before shutting down the object.
Perform the following steps to modify the frequency of the cell:
...................................................................................................................................................................................................

1 Run the following command at the command line:


lock-lcell:name=<full distinguished name of lcell>;

modifycell-lcell:<full distinguished name of lcell>,LCELLATTRS_UARFCNND=


<new value>;

unlock-lcell:name=<full distinguished name of lcell>;

Example:
lock-lcell:name=″LRNC=41,LNodeB=10,LCell=3″;

modifycell-lcell:name=″LRNC=41,LNodeB=10,LCell=3″,LCELLATTRS_UARFCNND=
4357;

unlock-lcell:name=″LRNC=41,LNodeB=10,LCell=3″;

E...................................................................................................................................................................................................
ND OF STEPS

....................................................................................................................................................................................................................................
6-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies Modify Node B frequency - CLI

Modified objects
This command modifies the LCell object.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-7
Issue 1, August 2007 See notice on first page
Radio frequencies

Modify Node B frequency - GUI


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to modify the frequency used in the downlink
direction for a Node B cell.
This OMC GUI is used in this procedure.
Important! Using the OMC CLI to modify the frequency will reduce the amount
of time required to perform this task. See “Modify Node B frequency - CLI”
(p. 6-5).

Related information
None.

Before you begin


Ensure that:
• you have appropriate CM privileges
• the required frequency is available. See “Verify RNC configured frequency”
(p. 6-3).

Procedure
Perform the following steps to modify the frequency of the cell:
...................................................................................................................................................................................................

1 At the Network Manager HM view, select the RNC object that manages the Node Bs
that require frequency modification.
...................................................................................................................................................................................................

2 Go to the View menu, select Show on tree.


...................................................................................................................................................................................................

3 In the RNC object tree, select the LNodeBTable and expend the tree.
Result: A list of LNodeB objects appear.
...................................................................................................................................................................................................

4 Select the LNodeB to be modified and expend its LCellTable.


Result: A list of LCell objects appear.
...................................................................................................................................................................................................

5 Right click the LCell object to be modified and select Modify UseCases -> Cell.

...................................................................................................................................................................................................................................
6-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies Modify Node B frequency - GUI

Result: The Modify UtranCell: Select MO to be modified window appears.


...................................................................................................................................................................................................

6 In the Modify UtranCell: Select MO to be modified window, highlight LRNC=z,


LNodeB=x, LCell=y object, and select the >> button.
Where:
z represents the RNC ID,
x represents the Node B ID, and
y represents the Cell ID.
Result: The selected object is placed in the List of selected objects.
...................................................................................................................................................................................................

7 Click Next, then select the LCell tab.


Locate the transmitter frequency and the umts frequency band.
...................................................................................................................................................................................................

8 In the LCell tab, use the selection arrows to set the Band in the umtsFrequencyBand
field.
...................................................................................................................................................................................................

9 In the LCell tab, set the new frequency in the uARFCNNd (downlink frequency) field.
The field is listed in the Transmitter frequency box.
Note: The uARFCNNu (uplink Frequency) is automatically set, hence it is not
necessary to define this frequency.
...................................................................................................................................................................................................

10 After you have made the changes, click Next.


Result: The Shutdown Timeout Timer window appears.
...................................................................................................................................................................................................

11 Click Finish to update the LCell transmit frequency.


Result: The LCell is reset.
Note: After the reset is successfully completed, The LCell will transmit on the new
frequency.
...................................................................................................................................................................................................

12 Verify that the new frequency is set in the LCell configuration window.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-9
Issue 1, August 2007 See notice on first page
Radio frequencies Modify Node B frequency - GUI

...................................................................................................................................................................................................

13 Repeat Step 1 to Step 12 for other LCell objects that require a frequency modification.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
6-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies

New frequency configuration

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides the procedures that should be performed to configure a new
frequency on the RNC.

Contents

Preliminary information 6-12


Add a new frequency 6-14
Check RNC configured frequency 6-16
RNC Reset 6-18
RNCTRACE Reset 6-20

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-11
Issue 1, August 2007 See notice on first page
Radio frequencies

Preliminary information
...................................................................................................................................................................................................................................

Overview
This topic lists the order in which procedures must be performed to add a new
frequency to the RNC. It also describes the consequences of RNC reset and the
frequency ranges.

New frequency configuration


Perform the procedures in the following order:
1. “Add a new frequency” (p. 6-14).
2. “Check RNC configured frequency” (p. 6-16).
3. “RNC Reset” (p. 6-18).
4. “RNCTRACE Reset” (p. 6-20).

RNC Reset
Adding a new frequency to the RNC will trigger the resetRequired flag to be set to
“true”. This requires the RNC to be reset after the new frequency is added.
Note: All Node Bs associated with the RNC will be unavailable during the RNC reset.
WARNING: An RNC reset is a service effecting action. If the RNC is in service,
contact the Market Program Manager to obtain permission to execute the reset.

Frequency
The frequency band and downlink frequency are needed prior to performing the
procedures. This table provides a frequency band and downlink frequency cross
reference.

Band Downlink Frequency


General (MHz) Additional (Channel)
I 10562 to 10838 N/A
II 9662 to 9938 412, 437, 462, 487, 512,
537, 562, 587, 612, 637,
662, 687
III 9037 to 9388 N/A
IV 10562 to 10763 1462, 1487, 1512, 1537,
1562, 1587, 1612, 1637,
1662

...................................................................................................................................................................................................................................
6-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies Preliminary information

Band Downlink Frequency


General (MHz) Additional (Channel)
V 4357 to 4458 1007, 1012, 1032, 1037,
1062, 1087
VI 4387 to 4413 1037, 1062

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-13
Issue 1, August 2007 See notice on first page
Radio frequencies

Add a new frequency


...................................................................................................................................................................................................................................

Purpose
This procedure describes how to add a new frequency to an existing RNC.

Related information
None.

Before you begin


Ensure that you have appropriate CM privileges.

Procedure
Perform the following steps to add a new frequency to an existing RNC:
...................................................................................................................................................................................................

1 At the Network Manager HM view, select the RNC object for which you want to add
a new frequency.
...................................................................................................................................................................................................

2 Click the arrow to the left of the RNC managed object to open the RNC tree.
...................................................................................................................................................................................................

3 Right click the LRNC object, and select Modify Usecases -> RNC.
Result: The Modify RNC: LRNC details view appears.
...................................................................................................................................................................................................

4 From the Modify RNC: LRNC details view, click on the LRNC tab, then click the
Add... button in the Freq box.
Result: The Parameters of freq window appears.
...................................................................................................................................................................................................

5 In the Parameters of freq window, click on the arrows in the frequencyBand field to
select the band, and enter the downlink frequency/channel in the frequency field.
...................................................................................................................................................................................................

6 Click the Add button to add the frequency.


Result: An hour glass appears.
...................................................................................................................................................................................................

7 After the frequency is added, click the Cancel button in the Parameters of freq
window.
...................................................................................................................................................................................................................................
6-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies Add a new frequency

In the Modify RNC: LRNC details view, verify that the new frequency and band class
have been added to the freq box.
Note: You may have to scroll through the window to see the added frequency.
...................................................................................................................................................................................................

8 Click Next in the Modify RNC: LRNC details view.


Result: The Shutdown Timeout Timer window appears.
...................................................................................................................................................................................................

9 Click Finish to add the new frequency to the RNC.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-15
Issue 1, August 2007 See notice on first page
Radio frequencies

Check RNC configured frequency


...................................................................................................................................................................................................................................

Purpose
This procedure describes how to verify a newly added frequency to the RNC.

Related information
None.

Before you begin


Ensure that you have appropriate CM privileges.

Procedure
Perform the following steps to verify the newly added frequency to the RNC:
...................................................................................................................................................................................................

1 At the Network Manager HM view, select the RNC object for which you want to
verify the new frequency was added.
...................................................................................................................................................................................................

2 Click the arrow to the left of the RNC managed object to open the RNC tree.
...................................................................................................................................................................................................

3 Double click the RNC object to open the detailed view.


Result: The RNC detailed view appears.
...................................................................................................................................................................................................

4 In the RNC detailed view, click on the LRNC tab, and use the arrows to check the
frequency in the freq box.
...................................................................................................................................................................................................

5 Verify that the frequency is listed.


...................................................................................................................................................................................................

6 If the new frequency is... then...


not listed repeat “Add a new frequency” (p. 6-14)
procedure.
listed end of steps.

...................................................................................................................................................................................................................................
6-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies Check RNC configured frequency

END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-17
Issue 1, August 2007 See notice on first page
Radio frequencies

RNC Reset
...................................................................................................................................................................................................................................

Purpose
This procedure describes how to reset the RNC.
WARNING! An RNC reset is a service affecting action. Approval must be obtained
before a reset is performed on an in-service RNC.

Related information
After adding a new frequency to the RNC, the resetRequired flag will set to “true” by
the system. This is because a reset of the RNC is required before the new frequency
can take effect.

Before you begin


Ensure that you have appropriate CM privileges.

Procedure
Perform the following steps to reset the RNC:
...................................................................................................................................................................................................

1 At the Network Manager HM view, select the RNC object that you want to reset.
...................................................................................................................................................................................................

2 Click the arrow to the left of the RNC managed object to open the RNC tree.
...................................................................................................................................................................................................

3 Double click the RNC object to open the detail view of the RNC.
Result: The RNC detailed view appears.
...................................................................................................................................................................................................

4 In the RNC detailed view, click the State tab to verify the resetRequired flag displays
“true”. If the flag is not “true”, then no reset is required and the remaining steps can
be skipped.
...................................................................................................................................................................................................

5 Right click the RNC object, then select Reset.


Result: The Reset window appears.
...................................................................................................................................................................................................

6 In the Reset window, select the force option, then click on the Finish button to reset
the RNC.

...................................................................................................................................................................................................................................
6-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Radio frequencies RNC Reset

Important! Depending on the size of the network, the RNC reset can take over 20
minutes to complete. The reset will finish once the RNC Full Tree Audit completes
at the OMC.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 6-19
Issue 1, August 2007 See notice on first page
Radio frequencies

RNCTRACE Reset
...................................................................................................................................................................................................................................

Purpose
This procedure describes how to reset the rnctrace level on all the CP blades.

Related information
None.

Before you begin


Ensure that you have appropriate CM privileges.

Procedure
Perform the following steps to reset the rnctrace level on all the CP blades:
...................................................................................................................................................................................................

1 Log in to the RNC as root.


...................................................................................................................................................................................................

2 Enter the following commands to change the rnctrace level:


for i in 03 04 05 06 07 08 09 10 11 12
-> do rsh fms$i ’. /.profile;/flx/bin/rnctrace
--level High --reset’
-> echo reset fms$i rnctrace level is complete
-> done
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
6-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
7 E 1T1 growth
7

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter describes how to add E1T1 connections.

Contents

E1T1 growth 7-2

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 7-1
Issue 1, August 2007 See notice on first page
E1T1 growth

E1T1 growth
...................................................................................................................................................................................................................................

Overview
This topic describes how to add new E1T1 links to an existing IMAGroup through the
OMC GUI and CLI.

Verify E1/T1 ports


Verify that all the growth E1/T1 ports are configured on the backplane of the Node B.
For more information on E1/T1 ports, refer to:
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
+24V, 401-382-462
• Lucent UMTS Modular Cell Outdoor, Operation, Administration and Maintenance
for +24V, 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
+24V, 401-382-961
• Lucent UMTS Microcell (Type M), Operation, Administration and Maintenance for
+24V, 401-382-966

E1T1 growth - GUI


Perform the following procedures to create an E1T1 port and associate it with an
IMAGroup:
1. Create the E1T1 port(s) by performing the “Create E1T1Port wizard” (p. A-73)
procedure.
2. Associate the newly created E1T1 port(s) with an IMAGroup by performing the
“Associate E1T1Port to IMAGroup wizard” (p. A-48) procedure.

E1T1 growth - CLI


Enter the following command at the OMC CLI to create an E1T1 port and associate it
with an IMAGroup:
ADDE1T1PORTTOIMA-imagroup:NAME=″NODEB=<a>,IMAGROUP=<b>″,
FORCECREATEE1T1PORTS=″<true or false>″ ,E1T1PORTATTRS={<c>:[NAME=″NodeB=
<d>,Frame=<e>,DigitalShelf=<f>,URC=<g>,E1T1Port=<h>″, MOID=<i>,
USERLABEL=″<j>″]},DIGITALSHELFID=<k>,URCID=<l>;

Where:
• a represents the Node B ID
• b represents the IMAGroup ID
• c represents the E1T1 Ports attributes
• d represents the name of the Node B
...................................................................................................................................................................................................................................
7-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
E1T1 growth E1T1 growth

• e represents the Frame ID


• g represents the Digital Shelf
• h represents the E1T1Port
• i represents the managed object ID
• j represents the user label
• k represents the Digital Shelf ID
• l represents the URC ID.
Example - 1 E1T1 Port:
ADDE1T1PORTTOIMA-imagroup:NAME=″NODEB=2024,IMAGROUP=1″,
FORCECREATEE1T1PORTS=″true″ ,E1T1PORTATTRS={3:[NAME=″NodeB=2021,Frame=1,
DigitalShelf=1,URC=1,E1T1Port=3″, MOID=3,USERLABEL=″T1 Port 3″]},
DIGITALSHELFID=1,URCID=1;

Example - 2 E1T1 Ports:


ADDE1T1PORTTOIMA-imagroup:NAME=″NODEB=2024,IMAGROUP=1″,
FORCECREATEE1T1PORTS=″true″ ,E1T1PORTATTRS={3:[NAME=″NodeB=2024,Frame=1,
DigitalShelf=1,URC=1,E1T1Port=3″, MOID=3,USERLABEL=″T1 Port 3″],4:[NAME=
″NodeB=2024,Frame=1,DigitalShelf=1,URC=1,E1T1Port=4″, MOID=4,USERLABEL=
″T1 Port 4″]},DIGITALSHELFID=1,URCID=1;

For more information about each CLI command and the required command syntax,
refer to the Lucent Operations and Maintenance Center - UTRAN Command Line
Interface, 401-380-072 manual.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 7-3
Issue 1, August 2007 See notice on first page
8 S SH and Telnet connections
8

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides the procedures to open a Secure Shell (SSH) session for the
OMC client to:
• An RNC

Contents

SSH cut-through to RNC 8-2


Telnet to a Node B 8-3

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 8-1
Issue 1, August 2007 See notice on first page
SSH and Telnet connections

SSH cut-through to RNC


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to open a Secure Shell (SSH) session from the OMC
client PC to an RNC.

Related information
There is no related information for this procedure.

Before you begin


Ensure that you have completed the configuration procedures listed in “IPSec and SSH
configuration tasks” (p. 29-6).

Procedure
Perform the following steps to open an SSH session:
...................................................................................................................................................................................................

1 In the Network Manager window select the FMS OA&M blade in the RNC that you
want to establish an SSH session with.
...................................................................................................................................................................................................

2 Go to the Tools menu and select Cut Through → SSH Cut Through.
Result: The SSH console is displayed.
...................................................................................................................................................................................................

3 At the SSH console, log on to the FMS blade as an RNC user, for example, primUser.
Important! If password authentication is disabled at the RNC, the connection
between the OMC-UPS and the RNC can only be done using key authentication.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
8-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
SSH and Telnet connections

Telnet to a Node B
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to open a Telnet session from the OMC client PC to
a Node B.

Related information
There is no related information for this procedure.

Before you begin


Make sure that you have permission to log in on the Node B through a Telnet session.

Procedure
Perform the following steps to log on the Node B through a Telnet session:
...................................................................................................................................................................................................

1 In the Network Manager window select the Node B.


...................................................................................................................................................................................................

2 Go to the tools menu and select Cut Through → Telnet Cut Through.
Result: A telnet session to the Node B is opened. The IP address that is used for
this connection is retrieved from the Telnet Host IP attribute of the NodeB
object.
...................................................................................................................................................................................................

3 Fill in the Login Name and Password to establish the Telnet session to the Node B.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 8-3
Issue 1, August 2007 See notice on first page
9 R ecommended OMC filters
9

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides the procedures to be used by the OMC administrator in order to
generate a number of recommended alarm filters that can be used during the alarm
surveillance process.
After the filters are created, they can be used by the OMC operator during the
day-to-day alarm surveillance process. These filters allow the operator to quickly
oversee the alarm status of the network elements or interfaces while performing Fault
Management (FM).
Note: The filters that are discussed in this topic are defined on the OMC. If a filter
needs to be defined to suppress alarm on a Node B or an RNC itself, refer to the
“Suppress alarms on a Node B or an RNC” (p. 13-13) topic.

Contents

Recommended filters 9-2


Create filter - critical alarms 9-3
Create filter - critical and major alarms 9-4
Create filter - all alarms during shift 9-5
Create filter - acknowledged alarm by user 9-7
Create filter - unacknowledged alarms 9-9

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 9-1
Issue 1, August 2007 See notice on first page
Recommended OMC filters

Recommended filters
...................................................................................................................................................................................................................................

Filters
Filters filter data and display only the data that is matching the filter criteria. The
OMC operator can create filters to filter for example by alarm severity or type of
alarm. Filters can be stored on the OMC server. In specific situations, like an overload
situation, the OMC operator can select the appropriate filter to see only the alarms that
are matching the filter criteria.

Recommended filters
Alarms are cleared by severity. During serious UTRAN network problems, many
alarms of a different severity are displayed in the Alarm Tables.
Therefore Lucent recommends to create the following filters:

Filter name Contents


Unacknowledged alarm filter Filter for all unacknowledged alarms
which are not cleared.
Acknowledged alarm by user filter Filter for all acknowledged alarms which
are acknowledged by you.
All alarms during shift filter Filter for all alarms that occur during your
shift.
Critical alarm filter Filter for critical alarms only.
Critical major alarm filter Filter for critical and major alarms only.

...................................................................................................................................................................................................................................
9-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Recommended OMC filters

Create filter - critical alarms


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to create a critical alarm filter.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Filter alarm procedure


Perform the following steps on the OMC to create a critical alarm filter.
...................................................................................................................................................................................................

1 At the Alarm Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 Select the Critical option in the severity section.


...................................................................................................................................................................................................

3 Select the Unacknowledged option in the Ack status section.


...................................................................................................................................................................................................

4 Click Save filter to save the filter.


...................................................................................................................................................................................................

5 Enter a representative file name for this filter, for example, OverloadCriticalAlarms, in
the Save Alarm Filter dialog window and select Save.
Result: The filter is saved and is available for future use.
If you cannot save the filter because the maximum number of filters has been
reached, contact your fault management administrator to delete an unnecessary
filter.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 9-3
Issue 1, August 2007 See notice on first page
Recommended OMC filters

Create filter - critical and major alarms


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to create critical and major alarm filters.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Filter alarm procedure


Perform the following steps on the OMC to create a critical and major alarm filter.
...................................................................................................................................................................................................

1 At the Alarm Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 Select the Critical and Major options in the severity section.


...................................................................................................................................................................................................

3 Select the Unacknowledged option in the Ack status section.


...................................................................................................................................................................................................

4 Click Save filter to save the filter.


...................................................................................................................................................................................................

5 Enter a representative file name for this filter, for example, OverloadCriticalMajo-
rAlarms, in the Save Alarm Filter dialog window and select Save.
Result: The filter is saved and is available for future use.
If you cannot save the filter because the maximum number of filters has been
reached, contact your fault management administrator to delete an unnecessary
filter.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
9-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Recommended OMC filters

Create filter - all alarms during shift


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to create all alarms during shift filters.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Filter alarm procedure


Perform the following steps on the OMC to create an all alarms during shift filter.
...................................................................................................................................................................................................

1 At the Alarm Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 In the Time section:


• Select the From option
• Insert the date of your shift in the Date field
• Insert the time your shift starts in the Time field.
...................................................................................................................................................................................................

3 Select one or more of the following in the severity section:


• Indeterminate
• Critical
• Major
• Minor
• Warning
• Cleared.
...................................................................................................................................................................................................

4 Click Save filter to save the filter.


...................................................................................................................................................................................................

5 Enter a representative file name for this filter, for example, AlarmDuringShift, in the
Save Alarm Filter dialog window and select Save.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 9-5
Issue 1, August 2007 See notice on first page
Recommended OMC filters Create filter - all alarms during shift

Result: The filter is saved and is available for future use.


If you cannot save the filter because the maximum number of filters has been
reached, contact your fault management administrator to delete an unnecessary
filter.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
9-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Recommended OMC filters

Create filter - acknowledged alarm by user


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to create acknowledged alarm by user filters.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Filter alarm procedure


Perform the following steps on the OMC to create an acknowledged alarm by user
filter.
...................................................................................................................................................................................................

1 At the Alarm Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 Select one or more of the following in the severity section:


• Indeterminate
• Critical
• Major
• Minor
• Warning
• Cleared.
...................................................................................................................................................................................................

3 Select the Unacknowledged option in the Ack status section.


...................................................................................................................................................................................................

4 Click Save filter to save the filter.


...................................................................................................................................................................................................

5 Enter a representative file name for this filter, for example, UnackAlarms, in the Save
Alarm Filter dialog window and select Save.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 9-7
Issue 1, August 2007 See notice on first page
Recommended OMC filters Create filter - acknowledged alarm by user

Result: The filter is saved and is available for future use.


If you cannot save the filter because the maximum number of filters has been
reached, contact your fault management administrator to delete an unnecessary
filter.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
9-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Recommended OMC filters

Create filter - unacknowledged alarms


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to create unacknowledged alarm filters.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Filter alarm procedure


Perform the following steps on the OMC to create an unacknowledged alarm filter.
...................................................................................................................................................................................................

1 At the Alarm Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 Select one or more of the following in the severity section:


• Indeterminate
• Critical
• Major
• Minor
• Warning
• Cleared.
...................................................................................................................................................................................................

3 Select the Acknowledged option in the Ack status section.


...................................................................................................................................................................................................

4 Enter your login ID in the Acknowledged by field.


...................................................................................................................................................................................................

5 Click Save filter to save the filter.


...................................................................................................................................................................................................

6 Enter a representative file name for this filter, for example, AckAlarmsByOmcadm, in
the Save Alarm Filter dialog window and select Save.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 9-9
Issue 1, August 2007 See notice on first page
Recommended OMC filters Create filter - unacknowledged alarms

Result: The filter is saved and is available for future use.


If you cannot save the filter because the maximum number of filters has been
reached, contact your fault management administrator to delete an unnecessary
filter.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
9-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
10 10 UTRAN Managed
The
Information Model (MIM)

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter includes the descriptions of the Managed Information Models (MIMs) that
are used in the different UTRAN elements.
These models function as the basis of how the UTRAN is represented on the OMC
and how the different objects are related to each other.

Contents

Introduction 10-2
The UTRAN information model 10-3
MIBs in the Lucent UTRAN 10-4
MIB contents 10-6
Working with the UTRAN MIB 10-8
Information Models 10-9
Introduction 10-10
SNM information model 10-11
RNC Information model 10-13
Node B information model 10-16

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-1
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

Introduction

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes how in the Node B, RNC and OMC, information is:
• Stored in a Managed Information Base (MIB)
• Managed by the Managed Information Model (MIM)
• Related to each other.

Contents

The UTRAN information model 10-3


MIBs in the Lucent UTRAN 10-4
MIB contents 10-6
Working with the UTRAN MIB 10-8

...................................................................................................................................................................................................................................
10-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM)

The UTRAN information model


...................................................................................................................................................................................................................................

Managed Information Base


Inside each network element data is available to indicate how the element should
operate and how it is configured. In each element this information is stored inside a
“database.”
The 3GPP specifications refer to this “database” as the Managed Information Base
(MIB).

Managed Information Model


The MIB of each network element needs a number of definitions. For example, to
indicate:
• How the information that is managed in the MIB, is structured
• The operations that are allowed on the managed information
• The notifications that the managed information is allowed to omit.
All these definitions that have been made for a MIB, are combined into a structure that
is referred to as the Managed Information Model (MIM).
Note that the MIM only defines how the MIB is structured together with the actions
that are allowed within this structure. It does not provide the actual contents of the
MIB!

MIM Example
A common example of a MIB and a MIM:

MIB example MIM example


A database that contains information about The database definitions that for example
all company employees. define that for each employee two mobile
numbers may be inserted in the database.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-3
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

MIBs in the Lucent UTRAN


...................................................................................................................................................................................................................................

Managed information in the Lucent UTRAN


The Lucent UTRAN can contain up to six MIBs where information is stored for
control and configuration of the network. These MIBs are located in the following
network elements:
• Node B controller
• RNC controller
• OMC-UPS
• Network Management System (optional).

Graphical representation
The following figure shows the location of the MIBs within the Lucent UTRAN:

Network Management
System NML

Itf-N
OMC-UPS

Integrated SNM
EML
Node B RNC
EM EM

Itf-B Itf-R

Iub NEL

Node B RNC

Node B and RNC MIBs SNM MIB

Partial Shadowed copy of Shadowed copy of


the Node B and RNC MIBs the SNM MIB (optional)

...................................................................................................................................................................................................................................
10-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM) MIBs in the Lucent UTRAN

Node B MIB
The Node B MIB contains all information that is needed to configure and control the
Node B hardware and the logical Node B objects (the cells) that are controlled by the
Node B.

RNC MIB
The RNC MIB contains all information that is needed to configure and control the
RNC hardware and the logical RNC objects (the location areas, handover parameters,
etc.) that are controlled by the RNC.

OMC-UPS MIBs
In the OMC-UPS three MIBs are available:

MIB name Description


Sub-Network Manager (SNM) Includes all information that:
MIB • Can be forwarded and accessed by the Network
Management Systems using the “Northbound”
interface (Itf-N interface)
• Is used by the OMC-UPS as a source “database”
to configure Node Bs and RNCs in the UTRAN.
Partial “shadowed” copy of the This copy allows the OMC operator continuously to
Node B MIB view the “last reported” functional state of the Node
B.
Partial “shadowed” copy of the This copy allows the OMC operator continuously to
RNC MIB view the “last reported” functional state of the RNC.

NMS MIB (optional)


If a Network Management System (NMS) is available, it is possible to store a (partial)
“shadowed” copy of the SNM MIB in the NMS. This copy allows the NMS operator
to view a subset of the SNM configuration when the NMS connection to the OMC is
lost.
Note that the availability of this particular MIB depends on the manufacturer of the
NMS.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-5
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

MIB contents
...................................................................................................................................................................................................................................

Overview
This topic provides the definitions that are needed to better understand the
object-oriented structure of the MIBs.

Definition
Objects Represent the basic building blocks of the MIB.
In the MIB, each object:
• Has a contained relationship with a parent object (except for the top object)
• Can be associated with other objects
• Consists of a number of attributes (parameters).

Definition
Object types Can represent either physical or logical resources. A physical object is
real and can be touched whereas a logical object is abstract in nature.
Examples of Physical and Logical Objects

Physical objects A host, an antenna, a hub, or a router.


Logical objects A local area network (LAN) or alarm log.

Definition
Attribute An attribute is a property carried by an object. This property is a condition,
value or predefined set of values. All objects have one or more attributes.

Definition
Parent-Attribute When an attribute exists of more than one property it is referred to
as a Parent-Attribute.

Definition
Sub-Attribute When an attribute exists of more than one property, the parent-attribute
can be divided into a number of sub-attributes. Each sub-attribute can be a
condition, value or predefined set of values.

...................................................................................................................................................................................................................................
10-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM) MIB contents

Definition
Contained relationship When an object has a contained relationship with another
object, there is a parent-child relation between these two objects. To be able to
create a child object, the parent object always needs to be present.

Definition
Associated relationship When an object has an associated relationship with another
object, the objects rely upon the services of each other. Neither object is
subordinate to the other but they are directly related, and neither can function
without the other. In some cases, an object that relies upon the service of another
object, cannot be created until the other object is created first.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-7
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

Working with the UTRAN MIB


...................................................................................................................................................................................................................................

Adding and removing objects


For each MIB object, definitions have been made that define if the object:
• Can be added
• Can be removed
• Is automatically created.

Inserting and updating attribute values


For each MIB attribute a definition has been made with available actions while
inserting or updating the attribute value.
The allowed actions per attribute are:

Key Code Definition Description


RO Read Only You cannot modify the attribute values.
RO-SC Read Only - Set On You cannot modify the attribute values.
Create The attribute can only be set through a
create object request.
RW Read Write You can modify the attribute values.
RW-EL Read Write - Element You can modify the attribute. The
Locked element must be locked before you can
modify the attribute.
RW-LO Read Write - Lock Object You can modify the attribute values. The
object must be locked before you can
modify the attribute.
RW-PL Read Write - Parent You can modify the attribute values. The
locked parent object must be locked before you
can modify the attribute.
RW-RR Read Write - Reset You can modify the attribute. Attribute
Required changes do not take effect until after a
reset of the object.

Reference
For more information about the actions that can be performed on each UTRAN
attribute, refer to the UTRAN Attribute Descriptions manual, 401-382-801.

...................................................................................................................................................................................................................................
10-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM)

Information Models

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes how objects are structured for the:
• SNM Information Model
• RNC Information Model
• Node B Information Model.

Contents

Introduction 10-10
SNM information model 10-11
RNC Information model 10-13
Node B information model 10-16

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-9
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

Introduction
...................................................................................................................................................................................................................................

Information models
When an OMC operator is performing UTRAN related tasks at the OMC GUI or CLI,
the operator must understand how all these managed objects:
• Are represented at the OMC (their names)
• Are related to each other (the contained and associated relationships that they
have).
All this information is provided in the information models.

Available information models


For the Lucent UTRAN the following information models are available:
• SNM
• RNC
• Node B.

...................................................................................................................................................................................................................................
10-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM)

SNM information model


...................................................................................................................................................................................................................................

Reduced GUI MIM visibility


To reduce the complexity of the OMC-UPS GUI, the OMC-UPS operator is offered a
MIM version with a reduced number of SNM objects on the GUI. This simplified
approach allows the operator a more clear overview of the status and structure of the
UTRAN.
To assure the correct operation of the OMC-UPS, the OMC-UPS wizards and CLI
commands have been created in such a way that they assure that all SNM information
that is not visible in on the GUI is still correctly populated in the SNM MIB.

CLI visibility
To assure that the SNM MIM is still fully accessible and manageable, the complete
model has been made accessible for OMC-UPS CLI users.

SNM information model - GUI


The following figure shows the objects of the SNM information model that are visible
on the OMC-UPS GUI:

Network

SNM

ItfBGroup Externals ItfRLink

ItfBLink

ExternalRnc Sgsn Msc

= Containment

The SNM MIM is located under the OMC-UPS folder in the Network manager
window.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-11
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM) SNM information model

SNM information model - CLI


The following figure shows the objects of the SNM information model that are visible
on the OMC-UPS CLI:

SNM

Rns VccQos Externals

LinkProfile

RncManagedElement NodeBManagedElement

VccDetail

ItfBGroup

b Uni
NodeBFunction ItfBLink
a b a

IubLink
a
b b
RncFunction IucsLink Msc
a
b
IupsLink Sgsn
a
b
UtranCell
IurLink ExternalRnc

ExternalUtranCell
ItfRLink

ExternalGSMCell

= Containment
= Association
= Not visible on the OMC GUI

....................................................................................................................................................................................................................................
10-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM)

RNC Information model


...................................................................................................................................................................................................................................

Overview
The RNC information model is too large to represent in one diagram, hence this model
has been divided into the following categories:
• Hardware related RNC objects
• Logical RNC objects.

RNC hardware information model


The following figure shows the objects of the RNC hardware information model that
are visible on the OMC GUI:

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-13
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM) RNC Information model

Network

Rns

LRNC

Cabinet ExtAlmBox SMLC

FBPShelf GICCPair

GICC CICC PSU SB ESC AC FanTray

CICCProc ESCProc

CICCBPEtherPort ESCBPEtherPort

GICCProc
ESCFAEtherPort

GICCBPEtherPort SBProc

GICCFAEtherPort SBClan

GICCSTM1OC3Port SBBPEtherPort

PG = Containment
= Association
= Pre-configured
= Refer to logical object tree

RNC logical information model


The following figure shows the objects of the RNC logical information model that are
visible on the OMC GUI:

....................................................................................................................................................................................................................................
10-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
The UTRAN Managed Information Model (MIM) RNC Information model

Network

Rns

LRNC

RFTrace IuPSSubNet UNIStack SuMgr SS7Stack LNodeB CellSP

IntraFreqMeas SS7LinkSet SS7StackInst


LCell

PeriodCriteria
FddExtCell
SS7Link
URA
GsmExtCell

LA
PRACH
PRNC IuR Iub IuPS IuCS

SCCPCHFach
PG

RA
SCCPCHPch

SAPS OCNS
ATMQOS

SACS OCNSHSDPA HSDPA

EDCH
= Pre-configured
= Containment
= Association
= Value valid for all

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 10-15
Issue 1, August 2007 See notice on first page
The UTRAN Managed Information Model (MIM)

Node B information model


...................................................................................................................................................................................................................................

Node B information model


The following figure shows the objects of the Node B information model that are
visible on the OMC GUI:

Network

Rns

NodeB

RFHead IMAGroup RETActuator ALDController GRS

Cell Frame Qos IubInterface ExtRxAmp


b
a

= Pre-configured DigitalShelf FilterShelf AmplifierShelf

= Containment
= Association
TDU Filter AmpShelfFan TxAmp

Radio CPC RxAmp

CTU UCU

AlarmHub OM
or IOU

DigitalShelfFan OCM

URC CPRIPort

E1T1Port E3T3Port STM1OC3Port EthernetPort

...................................................................................................................................................................................................................................
10-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Part IV: Fault Management

Overview
...................................................................................................................................................................................................................................

Purpose
This documentation part includes all tasks that an OMC operator can perform to do
Fault Management on the UTRAN.

References
For more information about performing Fault Management on the UTRAN, refer to:
UMTS Lucent OMC-UPS Operations, Administration, Maintenance, and Provisioning,
401-380-022

Contents

Chapter 11, Principles of maintenance 11-1


Chapter 12, Preventive maintenance 12-1
Chapter 13, Corrective maintenance - alarm surveillance 13-1
Chapter 14, Corrective maintenance - OMC alarm clearance procedures 14-1
Chapter 15, Corrective maintenance - Node B alarm clearance 15-1
procedures
Chapter 16, Corrective maintenance - RNC alarm clearance procedures 16-1
Chapter 17, Corrective maintenance - fault localization 17-1
Chapter 18, Corrective maintenance - fault correction 18-1
Chapter 19, Corrective maintenance - test correction 19-1
Chapter 20, Corrective maintenance - trouble administration 20-1

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary IV-1
Issue 1, August 2007 See notice on first page
11 Principles of maintenance
11

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter describes:
• How fault management can be performed in the UTRAN
• Which equipment can be used to perform fault management in the UTRAN
• The characteristics of the alarms that can be generated by the UTRAN.

Contents

UTRAN fault-management architecture 11-2


UTRAN alarm parameters 11-5
UTRAN alarm thresholds 11-8

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 11-1
Issue 1, August 2007 See notice on first page
Principles of maintenance

UTRAN fault-management architecture


...................................................................................................................................................................................................................................

Overview
UTRAN fault management:
• Provides the required functionality for the operator to detect faults
• Determines the cause of faults in the system
• Helps the operator to minimize the effect of the faults on the service provided by
the network
• Provides assistance to correct the fault.
Fault management monitors the operational and administrative states of each of the
network elements within the system that is controlled by the Element Managers (EM),
as well as the operational and administrative states of all the individual components of
the network elements.

Reference
UMTS fault management is based on the TMN management principles for fault
management that are defined in:
• ITU-T Recommendation M.3400: TMN Management Functions.
The requirements for UMTS fault management are outlined in:
• 3G Technical Specification 32.111: UMTS - 3G Configuration Management.
The requirements for alarm reporting are outlined in:
• ITU-T Recommendation X.733: Information Technology - Open Systems
Interconnection - System Management: Alarm reporting function

Fault-management architecture
The fault-management architecture for the UTRAN domain with the Integrated Fault
Manager (IFM) interfacing to the OMC and the OMC interfacing to the network
elements Node B and RNC:

...................................................................................................................................................................................................................................
11-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Principles of maintenance UTRAN fault-management architecture

Network Management System


ICM IIM IPM IFM NML

Itf-N
OMC
Integrated SNM
EML
Node B RNC
EM EM

Itf-B Itf-R

Iub
NodeB RNC NEL

RMT/LMT LMT

Element managers
The Element Managers (EM) collect and classify event and alarm messages and then
display the appropriate status to EM operators. The NEs are able to take defined
recovery action depending on the nature of the fault and the EM is also able to take
defined recovery action to return the network to an operational state.

OMC
The OMC combines the element-management functions for the UTRAN NEs in one
system. The OMC monitors and controls the RNC, the Node B and the external
equipment that is controlled from these NEs.
Functional blocks within the OMC:
• RNC Element Management (RNC EM) function
• Node B Element Management (Node B EM) function
• Integrated RNC/Node B Sub-Network Management (SNM) function.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 11-3
Issue 1, August 2007 See notice on first page
Principles of maintenance UTRAN fault-management architecture

LMT
The Local Maintenance Terminal (LMT) is attached to a single RNC. The
fault-management operator will have access to a RNC from the LMT terminal.

RMT
The Remote Maintenance Terminal (RMT) is attached to a single Node B. The
fault-management operator will have access to a Node B from the RMT terminal.

IFM
The Integrated Fault Manager (IFM) is the fault-management functionality that is
resident at the Network Management System (NMS) in the management hierarchy. The
IFM provides an overall view of the different types of equipment within the complete
UMTS system, including the outstanding alarms and the operational states of the NEs.

...................................................................................................................................................................................................................................
11-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Principles of maintenance

UTRAN alarm parameters


...................................................................................................................................................................................................................................

Fault-detection alarm parameters


For each fault that is detected in the Node B or RNC, the fault-detection process
supplies the following alarm parameters to the OMC:
• Affected component
• Alarm type
• Severity
• Probable cause
• Time when the fault was detected
• Nature of the fault
• Any other information that helps to understand the cause and the location of the
abnormal situation.

Affected component
The affected component indicates the hardware unit in which the defect has been
detected.
Identification of the affected unit:
• On the OMC the affected unit is indicated by its FDN.
An example of the FDN is: LRNC=1,Cabinet=1,FBPShelf=1,CICC=1.
• In the fault clearance procedures the affected unit is indicated in the first part of the
alarm name.
An example of the alarm name is: CICC_lostCommunication.

Alarm event types


Alarm event types that can occur in the network are:

Alarm event type Description


Communications An alarm of this type is principally associated with the
procedures and/or processes that are required to convey
information from one point to another.
Environmental An alarm of this type is principally associated with a
condition that relates to an enclosure in which the equipment
resides.
Equipment An alarm of this type is principally associated with an
equipment fault.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 11-5
Issue 1, August 2007 See notice on first page
Principles of maintenance UTRAN alarm parameters

Alarm event type Description


Processing error An alarm of this type is principally associated with a
software or processing fault.
Quality-of-service fault An alarm of this type is principally associated with a
degradation in the quality of a service.

Alarm severity
Alarms in the network can have the following degree of severity:

Severity Description
Critical A service-affecting condition has occurred and requires
immediate corrective action.
This degree of severity is used when a fault has affected the
service provided to the mobile user(s) such that no service can
be provided in some areas.
Major A service-affecting condition has occurred and urgent
corrective action is required.
This degree of severity is used when a fault has reduced rather
than removed the capability of the network to provide a
service.
Minor A non-service-affecting fault has occurred and corrective action
should be taken to prevent more serious faults.
Typically, minor faults are faults that do not degrade the
network capacity, maybe because redundant capacity was
available or the fault did not affect network traffic.
Warning A potential or impending service-affecting condition has been
detected.
The problem should be corrected to prevent it becoming
service-affecting.
Indeterminate The severity level cannot be determined.

Probable cause
The probable cause of the alarm indicates the most probable reason for triggering the
alarm.

...................................................................................................................................................................................................................................
11-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Principles of maintenance UTRAN alarm parameters

Examples of probable causes:


• equipmentMalfunction
• heatingOrVentilationOrCoolingSystemProblem
• powerProblem
• softwareError
• transmitFailure.

Nature of the alarm


The nature of the alarm can be as follows:

Nature Description
ADAC Alarms of this type are Automatically Detected and Automatically
Cleared (ADAC).
Alarms that belong to this category will automatically be removed
from the active list at the moment that the fault has been corrected.
Examples:
• The alarm is cleared when the unit has been replaced
successfully
• The alarm is automatically cleared when the software process
has successfully restarted.
ADMC Alarms of this type are Automatically Detected but must be
Manually Cleared (ADMC).
Alarms that belong to this category must be removed manually from
the OMC active alarm list at the moment that the fault has been
corrected.
Examples:
• After the unit has been replaced the alarm must be manually
reset
• After the software process has restarted the alarm must be
manually reset.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 11-7
Issue 1, August 2007 See notice on first page
Principles of maintenance

UTRAN alarm thresholds


...................................................................................................................................................................................................................................

Alarm thresholds
For certain Node B and RNC events, thresholds have been defined to indicate when an
alarm should be triggered. In almost all cases these threshold levels have been defined
internally in the NE and can not be changed.

Fault types
Thresholds are used to detect faults of the following types:

Fault type Example


Environmental fault High temperature.
Overload More than a given percentage of a system resource such as
disk space is being used.
Unacceptably frequent On a communication link one CRC error is unremarkable
transient errors but a rate of 10% is unacceptable.

Environmental faults
Upper and lower thresholds are used to detect an environmental condition and its
clearance. This method is used to prevent repeated reporting and clearance if a
condition fluctuates around a single threshold.
A second threshold may be defined at which the equipment is endangered by adverse
environmental conditions and more drastic action must therefore be taken, for example:
shut down autonomously.
Note
Most environmental conditions will be detected using external equipment, and will
therefore be detected as external alarms.

Overload conditions
Overload conditions are reported when a threshold is exceeded and cleared with
hysteresis.

Detection of repeated transient errors


For the detection of repeated transient errors, two sets of parameters are used:
• A maximum count of the number of transient events that can occur (N1)
• A time interval in which transient events are permitted (T1).

...................................................................................................................................................................................................................................
11-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Principles of maintenance UTRAN alarm thresholds

Process to detect repeated transient errors


The stages in the process to detect repeated transient errors:
...................................................................................................................................................................................................

1 When an error event occurs, start the timer T1.


...................................................................................................................................................................................................

2 For each subsequent error event, increment the error counter.


...................................................................................................................................................................................................

3 When ... then ...


T1 expires before the error count reset the error count.
has reached the threshold N1,
Threshold N1 is exceeded before report an error.
T1 expires,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 11-9
Issue 1, August 2007 See notice on first page
12 Preventive maintenance
12

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter contains all the tasks that should be performed by the OMC operator to
perform preventive maintenance on the UTRAN.

Related information
For more related information about preventive maintenance that should be performed
directly on the RNC or the Node B, refer to:
• Lucent RNC Operations, Administration and Maintenance, 401-382-360
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
+24V, 401-382-462
• Lucent UMTS Modular Cell Outdoor, Operation, Administration and Maintenance
for +24V, 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
+24V, 401-382-961
• Lucent UMTS Microcell (Type M), Operation, Administration and Maintenance for
+24V, 401-382-966.

Contents

Preventive maintenance schedule 12-2


Check UTRAN status 12-3
Check RF coverage 12-7

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 12-1
Issue 1, August 2007 See notice on first page
Preventive maintenance

Preventive maintenance schedule


...................................................................................................................................................................................................................................

Overview
This topic includes the time line for the different preventive maintenance tasks.

Preventive maintenance schedule


The schedule for preventive maintenance tasks:

Daily Weekly After After After Preventive maintenance task


installation config UTRAN
or change reboot
upgrade
Y Y Y Y “Check UTRAN status” (p. 12-3)

Y “Check RF coverage” (p. 12-7)


1 1
Y Y Y Y “Backup Node B” (p. 26-6)
1 1
Y Y Y Y “Backup RNC” (p. 26-4)
Notes:
1. Depending on the amount of configuration changes that are performed on the UTRAN, this task should
be performed on a daily basis (sometimes even several times a day) or on a weekly basis.

...................................................................................................................................................................................................................................
12-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Preventive maintenance

Check UTRAN status


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedures that can be performed to check the operational
status and alarm status of the complete UTRAN.
Note: The procedures that are provided in this topic are written as complementary
procedures to the normal alarm surveillance process that is described in the “Alarm
surveillance process” (p. 13-3).

Recommended time to perform this procedure


Since the outcome of this procedure can have influence on the normal day to day
alarm surveillance process, it is recommended to perform this procedure at the
beginning of the working day or shift.
Reference
Refer to “Preventive maintenance schedule” (p. 12-2) for more information about how
often this task should be performed from a preventive maintenance point of view.

Before you begin


No additional information is required before you begin this procedure.

Check active alarms


Perform the following steps on the to check whether there are any abnormalities in the
alarm status of the Node Bs and RNCs of the UTRAN:
...................................................................................................................................................................................................

1 Create and activate an alarm filter containing all (LRNC and NodeB) objects.
...................................................................................................................................................................................................

2 At the Fault Manager, go to the View menu and select Refresh to resynchronize the
current alarm view with the active alarms.
...................................................................................................................................................................................................

3 For each of the alarms that occurred as new alarms after the synchronization, decide
whether they need immediate attention or whether they can be solved at a later stage
during the “normal” day to day alarm surveillance process.
E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 12-3
Issue 1, August 2007 See notice on first page
Preventive maintenance Check UTRAN status

Check OMC versus UTRAN state


Perform the following steps on the OMC to check whether there are any differences
between the actual operational state and topological structure of the UTRAN and the
state that is provided at the OMC:
...................................................................................................................................................................................................

1 If ... then ...


you want to synchronize an RNC Select the LRNC object
you want to synchronize a Node Select the NodeB object
B

...................................................................................................................................................................................................

2 At the Network manager, go to the Action menu and:

If ... then ...


you want synchronize status Select Network Synchronization → Status.
you want synchronize the Select Network Synchronization → Tree Structure.
structure of the tree on the NE
view,

Result: The Network Synchronization message box opens.


...................................................................................................................................................................................................

3 Check the + subtree box if you want to include the child objects and click OK.
...................................................................................................................................................................................................

4 After the synchronization completed, determine whether any abnormalities are reported
by the OMC indicating differences between the UTRAN and the OMC. If any
abnormalities are reported, decide whether they need your immediate attention or
whether they can be solved at a later stage.
The generated report can be found in the http://<OMC-UPS server IP
address>:12000/reports/current/NEAuditLogReport directory.
E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
12-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Preventive maintenance Check UTRAN status

Check alarm log


Perform the following steps on the OMC to check whether there are any abnormalities
in the alarm log of the UTRAN:
...................................................................................................................................................................................................

1 Create an alarm filter and select:


• Date and time of the last time that this procedure has been performed in the From
box
• Current date and time in the To box
• Cleared in the Severity box
• All (LRNC and NodeB) objects in the object class box.
Result: An alarm table appears with all cleared alarms of all objects.
...................................................................................................................................................................................................

2 Browse through the cleared alarms and determine whether there were any
abnormalities that should be checked in further detail.
E...................................................................................................................................................................................................
ND OF STEPS

Check error log


Perform the following steps on the OMC to check whether there are any abnormalities
in the error log of the UTRAN:
...................................................................................................................................................................................................

1 Open the FM event log view containing all the error messages that were forwarded
from the UTRAN network elements to the OMC.
...................................................................................................................................................................................................

2 Activate a log view filter to view the errors that have been reported since the last time
that this procedure has been performed.
...................................................................................................................................................................................................

3 Browse through the error logs and determine whether there were any abnormalities that
should be checked in further detail.

E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 12-5
Issue 1, August 2007 See notice on first page
Preventive maintenance Check UTRAN status

Check operational state of UTRAN NEs


Perform the following steps on the OMC to check the operational state of the network
elements of the UTRAN:
...................................................................................................................................................................................................

1 At the Network Manager HM or NE view, select a NodeB, RNC or OMC.


...................................................................................................................................................................................................

2 Go to the View menu and select Object class table.


Result: The Object class table opens.
...................................................................................................................................................................................................

3 Select an object class in the Class-names List, left click and select View.
Result: A table opens showing the objects of the selected NE and their operational,
administrative and alarm state.
...................................................................................................................................................................................................

4 For each locked and disabled object, determine whether there were any operational
status abnormalities that should be checked in further detail.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
12-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Preventive maintenance

Check RF coverage
...................................................................................................................................................................................................................................

Overview
The measurements that can be used in preventive maintenance to test the RF network
coverage are:
• Drive test
• RF trace.
Reference
For more information about how often the RF coverage should be checked from a
preventive maintenance point of view, see the “Preventive maintenance schedule”
(p. 12-2) topic.

Drive test
Drive test equipment is used to measure downlink RF coverage.
Equipment typically consists of two components:
• UMTS receiver
• UMTS test phone.
The UMTS receiver is used to measure basic UMTS Node B transmitter characteristics
(for example Tx Power, Pilot level).
The test mobile is used to measure a downlink channel and record Physical and Layer
3 message to monitor the progress of a test call and identify potential causes of quality
affecting issues.

RF trace
The RF Trace capability is a service that allows the operator to gather radio related
information associated to a predefined UE.
Reference
For more information about the RF trace service:
• General information, refer to “RF trace” (p. 5-6)
• Procedures for managing RF traces, refer to “Manage the RF trace service”
(p. 27-8).

Measurement analysis
When measurements are performed regularly and the information is analyzed, an
operator can detect trends. For example deteriorating performances can be detected,
even before errors are generated.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 12-7
Issue 1, August 2007 See notice on first page
13 13
Corrective maintenance - alarm
surveillance

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides all the procedures that are needed to perform alarm surveillance
on the OMC for:
• RNC related alarms
• Node B related alarms.

Contents

Day to day alarm surveillance 13-2


Alarm surveillance process 13-3
Open the fault manager 13-6
Open standard alarm tables 13-7
Open alarm overload filter 13-9
Close alarm overload filter 13-11
Acknowledge an active alarm 13-12
Suppress alarms on a Node B or an RNC 13-13
Create an alarm suppression filter 13-14
Activate alarm suppression 13-16
Deactivate alarm suppression 13-18
Retrieve current alarm suppression settings 13-20
Modify an alarm suppression filter 13-22
Delete an alarm suppression filter 13-24
Alarm suppression attributes 13-26

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-1
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Day to day alarm surveillance

Overview
...................................................................................................................................................................................................................................

Purpose
This section includes the description of the day to day alarm surveillance process, as
well as the procedures that are needed to fulfill this process.

Contents

Alarm surveillance process 13-3


Open the fault manager 13-6
Open standard alarm tables 13-7
Open alarm overload filter 13-9
Close alarm overload filter 13-11
Acknowledge an active alarm 13-12

...................................................................................................................................................................................................................................
13-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance

Alarm surveillance process


...................................................................................................................................................................................................................................

Purpose
This topic describes the overall process that should be followed by the OMC operator
to perform alarm surveillance on the UTRAN.

Alarm surveillance process flow


The process flow indicating how an OMC operator should perform alarm surveillance
on the UTRAN:

Begin

Open the
1 fault manager

Open standard
2 alarm tables

Window
overloaded with Open alarm
3 overload filter
new alarms? Y

Overload Close alarm


4 alarm filter overload filter
active? Y

Abnor-
All alarms malities in the
5 acknowledged? UTRAN alarms?
Y N

N Y

Acknowledge Take appropriate


6 alarm action

Clear alarm using


7 alarm clearance
procedure

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-3
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance Alarm surveillance process

Alarm surveillance process


The procedural steps that should be taken to perform alarm surveillance on the
UTRAN are:
...................................................................................................................................................................................................

1 Open the fault manager using the “Open the fault manager” (p. 13-6) procedure.
...................................................................................................................................................................................................

2 Open the standard alarm tables using the “Open standard alarm tables” (p. 13-7)
procedure.
...................................................................................................................................................................................................

3 When ... then ...


the alarm window is overloaded use the “Open alarm overload filter” (p. 13-9)
with new alarms, procedure to activate one of the overload filters.
Continue at step 5.

...................................................................................................................................................................................................

4 When ... then ...


an alarm overload filter is active close the active overload alarm filter and reconnect
and all the alarms in the filtered the alarm tables using the “Close alarm overload
window have been cleared or filter” (p. 13-11) procedure.
acknowledged,

....................................................................................................................................................................................................................................
13-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Alarm surveillance process

...................................................................................................................................................................................................

5 When ... then ...


all alarms in the alarm tables check in the “all alarms during shift” table whether
have been acknowledged, there are any automatically cleared alarms in the
log view, which indicate that abnormalities have
occurred in the UTRAN.
When these abnormalities have been detected, take
the appropriate actions to solve them and return to
step 1.
Examples of abnormalities are:
• Processes that are restarted on a regular basis
• Alarms that occur on a regular basis
• OC3/STM1 interfaces that have framing errors
once in a while
• E1/T1 interfaces that have framing errors once
in a while.

...................................................................................................................................................................................................

6 When ... then ...


not all alarms in the alarm table acknowledge the new alarm(s) by following the
have been acknowledged, “Acknowledge an active alarm” (p. 13-12) process.

...................................................................................................................................................................................................

7 For each of the acknowledged alarms, solve the alarm by following the “Fault
correction process” (p. 18-3) process.
When finished return to step 1 once more to determine whether there are new alarms.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-5
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Open the fault manager


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to open the fault manager.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Open the fault manager


Perform the following steps to open the fault manager.
...................................................................................................................................................................................................

1 At the Desktop, go to the Alarms menu and select Fault Manager.


Result: The Fault Manager window opens.
...................................................................................................................................................................................................

2 Click the Maximize button in the upper right corner of the window to display the
window full screen.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
13-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance

Open standard alarm tables


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to open predefined alarm tables. With these
predefined alarm tables the OMC operator is able to monitor new alarms,
acknowledged alarms, and abnormal events in one view.

Related information
Refer to:
• “Create filter - all alarms during shift” (p. 9-5), to create an alarm filter that filters
all alarms that occur during your shift.
• “Create filter - acknowledged alarm by user” (p. 9-7), to create an alarm filter that
filters all alarms that are acknowledged by you.
• “Create filter - unacknowledged alarms” (p. 9-9), to create an alarm filter that
filters all alarms that are unacknowledged.

Before you begin


This procedure assumes that the “all alarms during shift”, “acknowledged alarms by
user”, as well as the “unacknowledged alarms” filters already have been created.

Open alarm tables


Perform the following steps to open standard alarm tables:
...................................................................................................................................................................................................

1 At the Fault Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

2 Select from the Custom filter drop-down list, the “all alarms during shift filter” and
check the following:
• The Date field shows the date of today
• The Time field shows the time your shift starts.
Click View table.
...................................................................................................................................................................................................

3 At the Fault Manager window, go to the Tools menu and select Filter.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-7
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance Open standard alarm tables

Result: The Alarm Filter window opens.


...................................................................................................................................................................................................

4 Select from the Custom filter drop-down list, the “acknowledged alarms by user filter”
and click View table.
...................................................................................................................................................................................................

5 At the Fault Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

6 Select from the Custom filter drop-down list, the “unacknowledged alarm filter” and
click View table.
...................................................................................................................................................................................................

7 At the Fault Manager window, go to the Windows menu and select Tile.
E...................................................................................................................................................................................................
ND OF STEPS

Result:
As a result of this procedure the alarm tables are displayed.

....................................................................................................................................................................................................................................
13-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance

Open alarm overload filter


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to open a predefined critical or a critical and major
alarm filter. This supresses all other alarms.
This filter should be activated at the moment that the alarm view window becomes
overloaded and therefore does not directly respond to the requests that are performed.

Related information
Refer to
• “Create filter - critical alarms” (p. 9-3), to create an alarm filter that filters all
critical alarms
• “Create filter - critical and major alarms” (p. 9-4), to create an alarm filter that
filters both the critical and major alarms.

Before you begin


This procedure assumes that the “critical” as well as the “critical and major” alarm
filters already have been created.

Open an alarm overload filter


Perform the following steps to open an alarm overload filter:
...................................................................................................................................................................................................

1 Disconnect the alarm tables by selecting the Disconnect/Connect the alarm browser
button in each alarm table.
...................................................................................................................................................................................................

2 At the Fault Manager window, go to the Tools menu and select Filter.
Result: The Alarm Filter window opens.
...................................................................................................................................................................................................

3 If... then...
the alarm window is severely select from the Custom filter drop-down list, the
overloaded, “overload critical alarms only filter”and click View
table.
the response time of the window select from the Custom filter drop-down list, the
is becoming to slow, “overload critical + major alarms only filter”and
click View table.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-9
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance Open alarm overload filter

Result: A new Alarm Table window opens, displaying only those alarms that are
matching the selected criteria and suppressing all other alarms.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
13-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance

Close alarm overload filter


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to close the predefined critical or critical and major
alarm overload filter.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Close an alarm overload filter


Perform the following steps to close the predefined critical or critical and major alarm
overload filter:
...................................................................................................................................................................................................

1 Close overload critical or critical and major alarm table.


...................................................................................................................................................................................................

2 Reconnect the standard alarm tables by selecting the Disconnect/Connect the alarm
browser button in each alarm table.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-11
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Acknowledge an active alarm


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure to acknowledge alarms.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Procedure
Perform the following steps to acknowledge an alarm:
...................................................................................................................................................................................................

1 In the Alarm Table, click on the alarm that you want to acknowledge.
...................................................................................................................................................................................................

2 Click Acknowledge on the Action menu.


Result: The Ack field in the Alarm Table changes to the acknowledged state for
the alarm.
E...................................................................................................................................................................................................
ND OF STEPS

Task result
A record is added to the alarm history, indicating that the alarm has been
acknowledged.
Important! Acknowledging the alarm only marks the alarm as acknowledged in the
element manager database; it does not affect the fault condition in the object itself.

...................................................................................................................................................................................................................................
13-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance

Suppress alarms on a Node B or an RNC

Overview
...................................................................................................................................................................................................................................

Purpose
This section includes the GUI procedures that can be used to suppress alarms on a
Node B or an RNC.
Alarm suppression can be useful when:
• Unimportant alarms keep on appearing on the OMC
• Certain Node Bs and/or RNCs are flooding the OMC with alarms. When this
happens, it might be useful to temporarily suppress all or part of the alarms of the
failing network element.

Contents

Create an alarm suppression filter 13-14


Activate alarm suppression 13-16
Deactivate alarm suppression 13-18
Retrieve current alarm suppression settings 13-20
Modify an alarm suppression filter 13-22
Delete an alarm suppression filter 13-24
Alarm suppression attributes 13-26

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-13
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Create an alarm suppression filter


...................................................................................................................................................................................................................................

Purpose
This topic provides the GUI procedure that can be used to create an alarm suppression
filter for a Node B or an RNC.
After creating a suppression filter, this filter can be activated for a particular Node B or
RNC using the “Activate alarm suppression” (p. 13-16) procedure.

Related information
There is no related information for this procedure.

Before you begin


Important! Suppressing alarms on a network element can severely affect the alarm
surveillance process! Therefore extreme caution should be taken to assure that no
other alarms are suppressed except the required ones.

Procedure
Perform the following steps to create an alarm suppression filter for a Node B or an
RNC:
...................................................................................................................................................................................................

1 If... then...
alarm suppression should be use the Network Manager Window to navigate to a
created for a Node B, randomly selected NodeB object.
alarm suppression should be use the Network Manager Window to navigate to a
created for an RNC, randomly selected LRNC object.

...................................................................................................................................................................................................

2 Go to the Tools menu and select Alarm Filter Administration => Create
<LRNC/NodeB> Alarm Filter.
Result: The Create <LRNC/NodeB> Alarm Filter window appears.
...................................................................................................................................................................................................

3 In the Create <LRNC/NodeB> Alarm Filter window specify the file name that should
be used for this filter.
...................................................................................................................................................................................................

4 Press Add to add a new alarm suppression definition.

...................................................................................................................................................................................................................................
13-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Create an alarm suppression filter

...................................................................................................................................................................................................

5 In the window use the pull down list to insert an alarm supression definition criteria.
Reference: Use the “Alarm suppression attributes” (p. 13-26) topic for more
information about the possible filter settings.
...................................................................................................................................................................................................

6 If... then...
more alarm suppression definitions should return to step 4.
be added to the alarm suppression filter,

...................................................................................................................................................................................................

7 Press Finish to complete adding the new alarm filter to the existing list of filters.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-15
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Activate alarm suppression


...................................................................................................................................................................................................................................

Purpose
This topic provides the GUI procedure that can be used to activate an alarm
suppression filter on a Node B or an RNC.
After activating an alarm filter, a predefined set of alarms will be suppressed at the
Node B/RNC and therefore they will not be forwarded to the OMC anymore.

References
For more information on how you can create an alarm suppression filter, refer to the
“Create an alarm suppression filter” (p. 13-14) procedure.

Before you begin


Important! Suppressing alarms on a network element can severely affect the alarm
surveillance process! Therefore extreme caution should be taken to assure that no
other alarms are suppressed except the required ones.

Procedure
Perform the following steps to activate alarm suppression for a Node B or an RNC:
...................................................................................................................................................................................................

1 If... then...
alarm suppression should be use the Network Manager Window to navigate to a
activated for a Node B, randomly selected NodeB object.
alarm suppression should be use the Network Manager Window to navigate to a
activated for an RNC, randomly selected LRNC object.

...................................................................................................................................................................................................

2 Double click on the “arrow” icon to open the randomly selected NodeB or LRNC in
the Network Element table view window.
...................................................................................................................................................................................................

3 Go to the Tools menu and select Alarm Filter Administration => Apply
<LRNC/NodeB> Alarm Filter.
Result: The Apply <LRNC/NodeB> Alarm Filter window appears containing the
currently defined alarm suppression filters.
...................................................................................................................................................................................................

4 Select the alarm suppression filter that should be activated and press the Next button.
...................................................................................................................................................................................................................................
13-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Activate alarm suppression

Result: A screen showing all the alarm suppression definitions of the selected
alarm filter appears.
...................................................................................................................................................................................................

5 If... then...
the alarm suppression filter definitions refer to the “Modify an alarm suppression
should still be updated before the filter filter” (p. 13-22)procedure.
should be activated,

...................................................................................................................................................................................................

6 Press Next to continue to the network element selection window.


...................................................................................................................................................................................................

7 From the list of FDNs, select the NodeB/LRNC for which the filter should be
activated.
Note: If needed more than one Node B or RNC can be selected.
...................................................................................................................................................................................................

8 Press Finish to activate (set) the modified filter settings.


Note: When the activation failed, the previously specified filter settings remain active.
Result: At the moment that the filter is activated on the Node B or RNC a new
filter is created including the identity of the Node B or RNC.
An example of a filter name that has been activated on the RNC number 10 is
RNC2.1_rnc10.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-17
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Deactivate alarm suppression


...................................................................................................................................................................................................................................

Purpose
This topic provides the GUI procedure that can be used to deactivate alarm suppression
on a Node B or an RNC.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Procedure
Perform the following steps to deactivate alarm suppression on a Node B or an RNC:
...................................................................................................................................................................................................

1 If... then...
alarm suppression should be use the Network Manager Window to navigate to a
deactivated for a Node B, randomly selected NodeB object.
alarm suppression should be use the Network Manager Window to navigate to a
deactivated for an RNC, randomly selected LRNC object.

...................................................................................................................................................................................................

2 Go to the Tools menu and select Alarm Filter Administration => Apply
<LRNC/NodeB> Alarm Filter.
Result: The Apply Alarm Filter window appears containing the current list of
alarm filters.
...................................................................................................................................................................................................

3 Using the pull-down list navigate to the <LRNC/NodeB>_nofilter filter.


Note: The default filter contains an empty suppression filter definition. When activated
this filter will overwrite the currently active suppression filter with an empty
suppression definition (meaning no filtering should be active).
...................................................................................................................................................................................................

4 Press Next twice.

...................................................................................................................................................................................................................................
13-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Deactivate alarm suppression

...................................................................................................................................................................................................

5 From the list of FDNs, select the NodeB/LRNC for which the filter should be
activated.
Note: If needed more than one Node B or RNC can be selected.
...................................................................................................................................................................................................

6 Press Finish to deactivate (unset) the filter settings on the selected NodeBs or RNCs.
Note: When the deactivation failed, the previously specified filter settings remain
active.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-19
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Retrieve current alarm suppression settings


...................................................................................................................................................................................................................................

Purpose
This topic provides the GUI procedure that can be used to retrieve (get) the current
alarm suppression settings of a Node B or an RNC.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

Procedure
Perform the following steps to retrieve the current alarm suppression settings of a
Node B or an RNC:
...................................................................................................................................................................................................

1 If... then...
alarm suppression should be use the Network Manager Window to navigate to
retrieved for a Node B, the NodeB object for which the settings should be
checked.
alarm suppression should be use the Network Manager Window to navigate to
retrieved for an RNC, the LRNC object for which the settings should be
checked.

...................................................................................................................................................................................................

2 Go to the Tools menu and select Alarm Filter Administration => Open
<LRNC/NodeB> Alarm Filter.
Result: The Open <LRNC/NodeB> Alarm Filter window appears containing the
currently defined alarm filters.
...................................................................................................................................................................................................

3 Select the alarm filter which contains the Node B or RNC identity for which you want
to view the current alarm settings.
An example of an activated filter name for RNC number 10 is RNC2.1_rnc10.
Note: If no filter is available no alarm suppression is active.

...................................................................................................................................................................................................................................
13-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Retrieve current alarm suppression settings

...................................................................................................................................................................................................

4 Press Cancel when you have finished checking the settings.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-21
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Modify an alarm suppression filter


...................................................................................................................................................................................................................................

Purpose
This topic provides the GUI procedure that can be used to modify the alarm definitions
of an existing alarm Node B or RNC suppression filter.
Note: This procedure only modifies the suppression filter definitions on the OMC. The
modifications that are made to a filter are not automatically activated in the Node Bs
or RNCs where this filter is currently activated.

Related information
To apply the modified filter to a Node B or RNC, use the “Activate alarm suppression”
(p. 13-16) procedure to overrule the current Node B or RNC settings.

Before you begin


Important! Suppressing alarms on a network element can severely affect the alarm
surveillance process! Therefore extreme caution should be taken to assure that no
other alarms are suppressed except the required ones.

Procedure
Perform the following steps to create an alarm suppression filter for a Node B or an
RNC:
...................................................................................................................................................................................................

1 If... then...
alarm suppression should be use the Network Manager Window to navigate to a
modified for a Node B, randomly selected NodeB object.
alarm suppression should be use the Network Manager Window to navigate to a
modified for an RNC, randomly selected LRNC object.

...................................................................................................................................................................................................

2 Go to the Tools menu and select Alarm Filter Administration => Open
<LRNC/NodeB> Alarm Filter.
Result: The Open <LRNC/NodeB> Alarm Filter window appears containing the
currently defined alarm filters.
...................................................................................................................................................................................................

3 Using the pull-down list navigate to the filter that should be modified.

...................................................................................................................................................................................................................................
13-22 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Modify an alarm suppression filter

...................................................................................................................................................................................................

4 Press the Next button.


...................................................................................................................................................................................................

5 If... then...
a filter definition should be added press Add to add the new alarm filter
definition to the existing list of filters.
a filter definition should be deleted press Delete to remove the alarm filter
definition from the existing list of filters.

Reference: Use the “Alarm suppression attributes” (p. 13-26) topic for more
information about the possible filter settings.
...................................................................................................................................................................................................

6 If... then...
more types of alarm suppression return to step 4.
definitions should be added or removed
from the alarm suppression filter,

...................................................................................................................................................................................................

7 Press Finish to save the modified alarm filter.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-23
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Delete an alarm suppression filter


...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure that can be used to delete an existing alarm
suppression filter.

Related information
There is no related information for this procedure.

Before you begin


Important! This procedure only deletes the alarm suppression filter definitions on
the OMC. If this filter has been activated on a Node B or RNC, it will still remain
active on the Node B/RNC until it has been deactivated!
To deactivate the active suppression filter for a specific Node B or RNC use the
“Deactivate alarm suppression” (p. 13-18) procedure.

Procedure
Perform the following steps to delete an alarm suppression filter:
...................................................................................................................................................................................................

1 If... then...
an alarm suppression should be use the Network Manager Window to navigate to a
deleted that has been defined to randomly selected NodeB object.
suppress alarms on a Node B,
an alarm suppression should be use the Network Manager Window to navigate to a
deleted that has been defined to randomly selected LRNC object.
suppress alarms on a RNC,

...................................................................................................................................................................................................

2 Go to the Tools menu and select Alarm Filter Administration => Delete
<LRNC/NodeB> Alarm Filter.
Result: The Delete <LRNC/NodeB> Alarm Filter window appears containing the
currently defined alarm filters.
...................................................................................................................................................................................................

3 Using the pull-down list navigate to the filter that should be deleted.

...................................................................................................................................................................................................................................
13-24 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Delete an alarm suppression filter

...................................................................................................................................................................................................

4 Press Delete to delete the alarm filter.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-25
Issue 1, August 2007 See notice on first page
Corrective maintenance - alarm surveillance

Alarm suppression attributes


...................................................................................................................................................................................................................................

Overview
This topic provides the description of the attribute values that are used for controlling
alarm suppression on a Node B or an RNC.

Criteria settings
The criteria settings are used to determine the alarms that should be suppressed for a
Node B or an RNC.
For the criteria the following settings are applicable:

Settings Description
severity Suppress all alarms of a specified severity
specificProblem Suppress all alarms with a specified
specificProblem.

FilterCriteria settings
The filterCriteria settings are used to determine the alarms that should be suppressed.
For the filterCriteria the following settings are applicable:

Possible options Possible options Description


severity all Suppress all alarms
critical Suppress all critical, major,
minor and warning alarms
major Suppress all major, minor and
warning alarms
minor Suppress all minor and warning
alarms
warning Suppress all warning alarms
specificProblem Specific problem name of an Suppress all alarms for this
alarm1 specific problem type.
Example: filesystem01Full

Scope settings
The scope settings are used for determining whether an alarm should be suppressed for
an element, a unit or for a certain group of alarms.
...................................................................................................................................................................................................................................
13-26 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - alarm surveillance Alarm suppression attributes

For the scope the following settings are applicable:

Settings Description
class Suppress all alarms of a specified alarm class
(group of alarms)
instance Suppress all alarms belonging to a specific
instance (object) of a Node B or RNC
element Suppress all alarms belonging to a specific Node
B or RNC.

FilterApplication settings
The filterApplication settings are used to define the name of the unit for the alarm(s)
that should be suppressed.
For the filterApplication the following settings are applicable:

Scope Possible options Description


class 1 The class for which the alarms Suppress alarms belonging to
should be blocked 2 this alarm class.
Example: PSU
instance 1 The DN or FDN of the Node B Suppress alarms belonging to
or RNC instance for which the this RNC or Node B instance.
alarm should be suppressed. Example: LRNC=9, Cabinet=1,
FBPShelf=1,SB=1
element NodeB DN or FDN Suppress alarms belonging to
this Node B.
Example: NodeB=3
RNC FDN Suppress alarms belonging to
this RNC.
Example: LRNC=9.

Notes:
1. The instance and the class filterapplication scopes can only be combined with the filtercriteria equal to
specificProblem

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 13-27
Issue 1, August 2007 See notice on first page
14 14
Corrective maintenance - OMC
alarm clearance procedures

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter contains the fault clearance procedures that are related OMC alarms
which have been generated due to problems in the UTRAN.

Contents

NE communication establishment failure 14-2


Event-driven overload on single NE 14-6
Heartbeat failed 14-8
Heartbeat failed: NE type mismatch 14-12
Heartbeat failed: NE version mismatch 14-14
Invalid NE communication parameters 14-16
Event capacity exceeded 14-17
Alarm information out of sync 14-19
NE alarm synchronization in progress 14-21
NE communication establishment failure 14-23
NE event could not be processed 14-27
Synchronization source mismatch 14-29
Unable to automatically delete PM data from NE 14-31
Unable to automatically retrieve PM data from NE 14-32
Unmanaged state set to NE 14-34
Remaining OMC alarm clearance procedures 14-36

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-1
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

NE communication establishment failure


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when there
is a NE communication establishment failure for receiving events or to synchronize
alarms.

Description
There is no connectivity between the OMC and the NE to receive events or to perform
alarm synchronizations. This alarm is created either on system startup or on NE
creation.

Severity
CRITICAL

Probable cause
• The network element is down
• Problems in the LAN network
• Problems in the transmission network between the OMC-UPS and the network
element.

System impact
• Autonomous NE updates (state changes, alarms, etc.) will not appear on the system
for that NE
• Alarm synchronization operation will fail for that NE
• The system will reflect the last known state for that NE before the communication
was lost.
• Lost calls due to a failing network element
• Technician maintenance requests from the OMC-UPS will be denied

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
14-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

To clear alarm
...................................................................................................................................................................................................

1 If the alarm occurs for more than one network element, check the network
(LAN/WAN) connections.
...................................................................................................................................................................................................

2 If the heartbeat failure is indicated for a given NE, check the appropriate fault
clearance procedures for the different heartbeat failures.
E...................................................................................................................................................................................................
ND OF STEPS

RNC Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether RNC processes are initialized by RCC and AMW (system
software)

If ... then ...


FMS 1 and FMS 2 are not bring the RNC down and initialize again.
initialized by the system
software,

Result: After initialization the BSC OAM process is running on either FMS1 or
FMS2.
...................................................................................................................................................................................................

2 Check the TCP/IP communication between the RNC and the OMC-UPS.
FMS 1 and FMS 2 should be able to ping the OMC-UPS External IP address.
Similarly, the OMC-UPS should be able to ping the external FMS IP address
provisioned.
Additionally the RNC’s FWRVCVM IP address needs to be pingable.
If it is not possible to ping the OMC-UPS and/or the FMS check:
• Infrastructure cable connections and cable connectors
• Ethernet-Switch Port set up in the RNC
• IP address of OMC-UPS of /etc/hosts as configured during RNC installation

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-3
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

• Incorrect infrastructure static IP routes


• RNC ARP table resolution problems. The solaris backbone system may need its
ARP entries deleted such that a refresh occurs autonomously as part of the RNC
intialization.
...................................................................................................................................................................................................

3 Check the throughput of the actual Itf-r link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

4 Contact Alcatel-Lucent customer support to check the database as installed in the RNC
and in the OMC-UPS (data scripts). Errors when populating data lead to inabilities for
the registration use case to complete.
E...................................................................................................................................................................................................
ND OF STEPS

Node B Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the Node B and the OMC-UPS.
The OMC-UPS should be able to ping the external Node B OAM&P IP address.
If it is not possible to ping the Node B, check:
• Infrastructure cable connections and cable connectors
• Correct Configuration of DHCP-Server, from which the NodeB retrieves its IP
address as well as netmasks, etc.
• Correct setup of IP interfaces on LIU and UMC of the NodeB
• Correct setup of ERM-Module in PSAX connected to NodeB.
...................................................................................................................................................................................................

2 Check the throughput of the actual Itf-b link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.

E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
14-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

CGF or SGSN Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the CGF or SGSN and the OMC-UPS.
The OMC-UPS should be able to ping the external IP address of the NE.
• Ping the CGF or SGSN from the OMC-UPS server
...................................................................................................................................................................................................

2 If it is not possible to ping the CGF or SGSN, clear the IPsec settings on both the
OMC-UPS and the NE then ping again to determine if there are possible network
problems.
To clear the IPSec settings:
• SSH to the NE and run “showIPsec ca” or
• From the OMC-UPS server /omc/OMC-U/scripts/ directory run “./disable_ipsec.sh
ipaddress”
...................................................................................................................................................................................................

3 If the problem persists, verify that the OMC-UPS IP address is configured for SNMP
Management, that the system IP address is valid and that the Community String is
enabled.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-5
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Event-driven overload on single NE


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when a
predefined overload threshold was exceeded for a specified NE.

Description
This overload condition occurs when the system is receiving more events from the NE
than the number specified by the threshold.

Severity
MINOR, MAJOR or CRITICAL based on overload severity.

Probable cause
• The system is receiving events over a predefined threshold
• The network element performs a reboot
• The network element is in an unstable state

System impact
• The system performance may be affected when receiving more events that it can
handle at a given time. This impact depends on the threshold levels being exceeded
and the load of the system when the overload condition is raised.
• Autonomous system updates (state changes, alarms, etc.) will not appear on the
OMC-UPS.
• The OMC-UPS will reflect the last known state of the system before the event
buffer became overloaded (shadowed mode).

Related information
Thresholds can be established per NE type and per event type (alarms and non-alarms
event types). Thresholds are defined by the detection and abatement levels, which are
both the same.
By default the system takes the following corrective actions to abate the overload
condition. These corrective actions depend on the threshold being exceeded
• Minor: no corrective actions are taken by the system.
• Major: discard all the events coming from this NE if it is a normal priority one.
• Critical: discard all the events coming from this NE whether the NE is high or
normal priority.

...................................................................................................................................................................................................................................
14-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Event-driven overload on single NE
procedures

If an overload condition starts at a given severity, all the actions defined for each lower
severity will be executed before starting the corrective actions for the current severity.
For example, if the overload condition starts at critical severity, all the corrective
actions defined for minor and major severity will be executed before proceeding with
those actions defined for the critical level. Events will be processed again once the
overload condition of the given severity is abated. Events discarded by the corrective
actions will be processed again when the NE is re-synchronized.

Before you begin


By default this alarm is automatically cleared by the system as soon as the overload
condition is abated as described above. If the overload condition last too long or there
is no apparent reason for the system to get into overload state, then follow the next
steps.

To clear alarm
Contact the system administrator and alert them about the problem. The system
administrator may need to perform the following actions:
...................................................................................................................................................................................................

1 Analyze the message to determine the NE causing the overload. Then check if this NE
has any kind of problem that makes it to send an excess of events. Set the NE to
unmanage state to stop receiving burst of events from it.
...................................................................................................................................................................................................

2 Check the overload threshold levels are correctly established. They can have too low
values so the overload conditions are raised too soon. Change the thresholds if they do
not fit your environment.
...................................................................................................................................................................................................

3 Once the problem is resolved, perform a manual re-synchronization of the NE if


needed.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-7
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Heartbeat failed
...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when an NE
heartbeat fails.

Description
This alarm is generated when the heartbeat synchronization signal between the
indicated Network element and the OMC is lost. This happens when you cannot access
the NE or when there is a NE type or NE version mismatch. The default parameter for
heartbeat frequency is one minute.

Severity
Critical when there is a NE type mismatch and Major when there is an NE version
mismatch.

Probable cause
• The network element is down
• Problems in the LAN network
• Problems in the transmission network between the OMC-UPS and the network
element.

System impact
• Lost calls due to a failing network element.
• Alarms and events from the NE are lost
• Technician maintenance request from the management system will be denied.
• Autonomous system updates such as state changes will not appear on the OMC.
• The OMC will reflect the last known state of the system before the communication
was lost (shadowed mode).

Related information
There is no related information for this procedure.

Before you begin


Set the Severity to Cleared.
When you clear or update an alarm, do not change the value of the following fields:
• ObjectName
• EventType
...................................................................................................................................................................................................................................
14-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Heartbeat failed
procedures

• ProbableCause
• SpecificProblems
If the values in these fields are not retained, the alarm is not cleared and a new alarm
is generated with a new value in the SpecificProblems field.

To clear alarm
...................................................................................................................................................................................................

1 When the heartbeat is successful, this alarm is auto cleared.


...................................................................................................................................................................................................

2 After the connection is restored, perform a full audit and synchronize the alarm on the
affected NE.
E...................................................................................................................................................................................................
ND OF STEPS

RNC Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether the RNC processes are initialized by RCC and AMW
(system software).

If ... then ...


FMS 1 and FMS 2 are not bring the RNC down and initialize again.
initialized by the system
software,

Result: After initialization the BSC OAM process is running on either FMS1 or
FMS2.
...................................................................................................................................................................................................

2 Check the TCP/IP communication between the RNC and the OMC-UPS.
FMS 1 and FMS 2 should be able to ping the OMC-UPS External IP address.
Similarly, the OMC-UPS should be able to ping the external FMS IP address
provisioned.
Additionally the RNC’s FWRVCVM IP address needs to be pingable.
If it is not possible to ping the OMC-UPS and/or the FMS check:
• Infrastructure cable connections and cable connectors
• Ethernet-Switch Port set up in the RNC
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-9
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance Heartbeat failed
procedures

• IP address of OMC-UPS of /etc/hosts as configured during RNC installation


• Incorrect infrastructure static IP routes
• RNC ARP table resolution problems. The Solaris backbone system may need its
ARP entries deleted such that a refresh occurs autonomously as part of the RNC
initialization.
...................................................................................................................................................................................................

3 Check the throughput of the actual Itf-r link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

4 Contact Alcatel-Lucent customer support to check the database as installed in the RNC
and in the OMC-UPS (data scripts). Errors when populating data lead to inabilities for
the registration use case to complete.
E...................................................................................................................................................................................................
ND OF STEPS

Node B Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the Node B and the OMC-UPS.
The Node B should be able to ping the OMC-UPS external IP address.
If it is not possible to ping the Node B, check:
• Infrastructure cable connections and cable connectors
• Correct Configuration of DHCP-Server, from which the NodeB retrieves its IP
address as well as netmasks, etc.
• Correct setup of IP interfaces on LIU and UMC of the NodeB
• Correct setup of ERM-Module in PSAX connected to NodeB.
...................................................................................................................................................................................................

2 Check the throughput of the actual Itf-b link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.

E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
14-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Heartbeat failed
procedures

CGF or SGSN Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the CGF or SGSN and the OMC-UPS.
The OMC-UPS should be able to ping the external IP address of the NE.
• Ping the CGF or SGSN from the OMC-UPS server
...................................................................................................................................................................................................

2 If it is not possible to ping the CGF or SGSN, clear the IPsec settings on both the
OMC-UPS and the NE then ping again to determine if there are possible network
problems.
To clear the IPSec settings:
• SSH to the NE and run “showIPsec ca” or
• From the OMC-UPS server /omc/OMC-U/scripts/ directory run “./disable_ipsec.sh
ipaddress”
...................................................................................................................................................................................................

3 If the problem persists, verify that the OMC-UPS IP address is configured for SNMP
Management, that the system IP address is valid and that the Community String is
enabled.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-11
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Heartbeat failed: NE type mismatch


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when a NE
Heartbeat fails (NE type mismatch)

Description
The management system is not able to contact the network element, because the
contacted network element does not match the expected network element type.
Important! This alarm must be cleared manually.

Severity
CRITICAL

Probable cause
• The IP address entered on the OMC-UPS has been set incorrectly
• Problems in the DHCP pool.

System impact
• Technician maintenance requests from the management system will be denied
• Autonomous system updates (state changes, alarms, PM, etc.) will not appear on
the management system.
• The OMC will reflect the last known state of the system before the communication
was lost (shadowed mode).

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 At the OMC, verify if the specified type matches the expected type of the network
element.

...................................................................................................................................................................................................................................
14-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Heartbeat failed: NE type mismatch
procedures

...................................................................................................................................................................................................

2 At the OMC, verify if the specified IP address matches the actual IP address of the
network element.
...................................................................................................................................................................................................

3 At the OMC, set the network element to UNMANAGE state and delete the network
element.
...................................................................................................................................................................................................

4 Create a new network element with the correct element type.


...................................................................................................................................................................................................

5 If the problem is resolved, manually clear the alarm.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support. A suspect alarm


cannot be cleared manually; however, the alarm will be cleared automatically after the
problem is resolved.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-13
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Heartbeat failed: NE version mismatch


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when a NE
heartbeat fails due to NE version mismatch.

Description
The OMC is not able to contact the network element, because the software version
running on the contacted network element does not match the expected software
version.
Important! This alarm must be cleared manually.

Severity
MAJOR

Probable cause
Network element runs on a different software version then the OMC-UPS currently
supports.

System impact
• Technician maintenance requests from the management system will be denied.
• Autonomous system updates such as state changes will not appear on the OMC.
• The OMC will reflect the last known state of the system before the communication
was lost (shadowed mode).

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 At the OMC, check whether the specified software version matches the expected
software version of the network element. If the software version has been set
incorrectly, set the network element to UNMANAGE state and modify the software
version.

...................................................................................................................................................................................................................................
14-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Heartbeat failed: NE version mismatch
procedures

...................................................................................................................................................................................................

2 If ... then ...


the alarm was reported for an at the RNC, check if the current software version
RNC, matches the software version that is expected on
the OMC-UPS.
the alarm was reported for an at the Node B, check if the current software
Node B, version matches the software version that is
expected on the OMC-UPS.
the alarm was reported for an at the respective network element, check if the
SGSN or CGF, current software version matches the software
version that is expected on the OMC-UPS.

...................................................................................................................................................................................................

3 If the problem is resolved, manually clear the alarm.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-15
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Invalid NE communication parameters


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when the
NE communication parameters are invalid.

Description
The communication parameters provided for this network element are not correct.

Severity
CRITICAL

Probable cause
Communications protocol error.

System impact
• Autonomous NE updates (state changes, alarms, etc.) will not appear on the system
for that NE
• Alarm synchronization operation will fail for that NE
• The system will reflect the last known state for that NE before the communication
was lost.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 At the OMC-UPS, verify the communication parameters for the NE.


...................................................................................................................................................................................................

2 If all communication parameters are correct, contact the system administrator and alert
them to this alarm
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

Event capacity exceeded


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when the
maximum number of incoming and not yet processed events per a specific NE has
been exceeded.

Description
The OMC has reached the threshold value for the maximum number of incoming and
not yet processed events for the reported network element.
Important! This alarm must be cleared manually. Alarm Correlation can also use
Auto Detect Manual Clear (ADMC) alarms.

Severity
MAJOR

Probable cause
• The NE performs a reboot
• The NE is in unstable phase

System impact
• Technician maintenance request from the OMC will be denied.
• Autonomous system updates such as state changes will not appear on the OMC.
• The OMC will reflect the last known state of the system before the event buffer
became overloaded (shadowed mode).

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 If ... then ...


the overload is created by few different use the Alarm Filtering Administration
event types tool to suppress these NE events.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-17
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance Event capacity exceeded
procedures

If ... then ...


the overload is created by a many put the NE in the unmanaged state until
different event types the OMC-UPS load has reduced.

...................................................................................................................................................................................................

2 At the OMC, verify if there are alarms that indicate the reason for the NE overload.
...................................................................................................................................................................................................

3 Perform a full tree network synchronization on the NE reporting the problem.


...................................................................................................................................................................................................

4 From the Network Manager, select the NE and perform an alarm synchronization.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

Alarm information out of sync


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault caused when the alarm
related information is out of sync.

Description
This alarm is raised when the alarm synchronization or an event has failed to update
alarms.

Severity
Major

Probable cause
• Failure on the creation or update of an alarm from either the user or from a fault
event
• Failure updating alarms on an alarm synchronization process
• Failure on the update of counters of the Alarm Summary

System impact
The alarm information displayed for this NE may not represent the current status.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 Analyze the message to determine the problem. Check the probable cause of the alarm.
...................................................................................................................................................................................................

2 Perform a manual synchronization and clear the alarm.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-19
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance Alarm information out of sync
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

NE alarm synchronization in progress


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when the
OMC is performing an alarm synchronization for an NE. The alarms reflected for this
network element are not synchronized with the network element until the operation is
complete.

Description
When an alarm synchronization is initiated on a network element, the OMC raises a
suspect alarm on this NE to indicate that the alarm synchronization is in progress.

Severity
WARNING when the alarm synchronization is in progress and MAJOR if
synchronization fails.

Probable cause
The network connection with the network element has failed.

System impact
• Autonomous NE updates such as state changes will not take place until the alarm
synchronization finishes.
• Further alarm synchronization requests on the same NE will not take place.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-21
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance NE alarm synchronization in progress
procedures

To clear alarm
...................................................................................................................................................................................................

1 Acknowledge the alarm and wait until the synchronization is complete. A suspect alarm
cannot be cleared manually; however, the alarm will be cleared automatically when the
alarm synchronization is completed successfully. If the synchronization is not
completed successfully, the alarm will be cleared on the next successful
synchronization on the specified NE.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-22 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

NE communication establishment failure


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when there
is a NE communication establishment failure for receiving events or to synchronize
alarms.

Description
There is no connectivity between the OMC and the NE to receive events or to perform
alarm synchronizations. This alarm is created either on system startup or on NE
creation.

Severity
CRITICAL

Probable cause
• The network element is down
• Problems in the LAN network
• Problems in the transmission network between the OMC-UPS and the network
element.

System impact
• Autonomous NE updates (state changes, alarms, etc.) will not appear on the system
for that NE
• Alarm synchronization operation will fail for that NE
• The system will reflect the last known state for that NE before the communication
was lost.
• Lost calls due to a failing network element
• Technician maintenance requests from the OMC-UPS will be denied

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-23
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

To clear alarm
...................................................................................................................................................................................................

1 If the alarm occurs for more than one network element, check the network
(LAN/WAN) connections.
...................................................................................................................................................................................................

2 If the heartbeat failure is indicated for a given NE, check the appropriate fault
clearance procedures for the different heartbeat failures.
E...................................................................................................................................................................................................
ND OF STEPS

RNC Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether RNC processes are initialized by RCC and AMW (system
software)

If ... then ...


FMS 1 and FMS 2 are not bring the RNC down and initialize again.
initialized by the system
software,

Result: After initialization the BSC OAM process is running on either FMS1 or
FMS2.
...................................................................................................................................................................................................

2 Check the TCP/IP communication between the RNC and the OMC-UPS.
FMS 1 and FMS 2 should be able to ping the OMC-UPS External IP address.
Similarly, the OMC-UPS should be able to ping the external FMS IP address
provisioned.
Additionally the RNC’s FWRVCVM IP address needs to be pingable.
If it is not possible to ping the OMC-UPS and/or the FMS check:
• Infrastructure cable connections and cable connectors
• Ethernet-Switch Port set up in the RNC
• IP address of OMC-UPS of /etc/hosts as configured during RNC installation

...................................................................................................................................................................................................................................
14-24 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

• Incorrect infrastructure static IP routes


• RNC ARP table resolution problems. The solaris backbone system may need its
ARP entries deleted such that a refresh occurs autonomously as part of the RNC
intialization.
...................................................................................................................................................................................................

3 Check the throughput of the actual Itf-r link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

4 Contact Alcatel-Lucent customer support to check the database as installed in the RNC
and in the OMC-UPS (data scripts). Errors when populating data lead to inabilities for
the registration use case to complete.
E...................................................................................................................................................................................................
ND OF STEPS

Node B Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the Node B and the OMC-UPS.
The OMC-UPS should be able to ping the external Node B OAM&P IP address.
If it is not possible to ping the Node B, check:
• Infrastructure cable connections and cable connectors
• Correct Configuration of DHCP-Server, from which the NodeB retrieves its IP
address as well as netmasks, etc.
• Correct setup of IP interfaces on LIU and UMC of the NodeB
• Correct setup of ERM-Module in PSAX connected to NodeB.
...................................................................................................................................................................................................

2 Check the throughput of the actual Itf-b link. Check the Transport Network or
connection and throughput to ensure no dropped packets are occurring.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.

E...................................................................................................................................................................................................
ND OF STEPS

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-25
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance NE communication establishment failure
procedures

CGF or SGSN Fault clearance procedure


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 Check the TCP/IP communication between the CGF or SGSN and the OMC-UPS.
The OMC-UPS should be able to ping the external IP address of the NE.
• Ping the CGF or SGSN from the OMC-UPS server
...................................................................................................................................................................................................

2 If it is not possible to ping the CGF or SGSN, clear the IPsec settings on both the
OMC-UPS and the NE then ping again to determine if there are possible network
problems.
To clear the IPSec settings:
• SSH to the NE and run “showIPsec ca” or
• From the OMC-UPS server /omc/OMC-U/scripts/ directory run “./disable_ipsec.sh
ipaddress”
...................................................................................................................................................................................................

3 If the problem persists, verify that the OMC-UPS IP address is configured for SNMP
Management, that the system IP address is valid and that the Community String is
enabled.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-26 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

NE event could not be processed


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when a NE
event could not be processed

Description
An network element could not be processed because the event type that was passed on
was incorrect.

Severity
WARNING

Probable cause
Lock could not be acquired, or the management system detected that one MO for
which one or more events have been received, is not found in the management system
database.

System impact
The OMC and the network element are not 100% synchronized. Any attribute value
change related to MO not found in OMC database could not be handled.

Related information
Important! This alarm must be cleared manually. Alarm Correlation can also use
alarms with nature ADMC.

Before you begin


Perform a data synchronization on the NE.

To clear alarm
...................................................................................................................................................................................................

1 Perform a full tree network synchronization on the NE reporting the problem.


...................................................................................................................................................................................................

2 Using the System Alarm window, select the NE for which the alarm has been reported
and perform an alarm synchronization.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-27
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance NE event could not be processed
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-28 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

Synchronization source mismatch


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the Synchronization source mismatch
alarm.

Description
OMC-UPS has detected that a configuration value was changed on the network
element.
Important! This alarm must be cleared manually. Alarm Correlation can also use
Auto Detect Manual Clear (ADMC) alarms.

Severity
Warning

Probable cause
The configuration data on the network has been altered directly without using
OMC-UPS.

System impact
• Technician maintenance request from the management system will be denied.
• Autonomous system updates (state changes, alarms, etc.) will not appear on the
management system.
• The management system will reflect the last known state of the system before the
event buffer became overloaded (shadowed mode).
• The OMC-UPS and the network element are not fully synchronized.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 At the OMC, verify if there are alarms that indicate why the NE is creating the
overload.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-29
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance Synchronization source mismatch
procedures

...................................................................................................................................................................................................

2 Perform a full tree network synchronization on the NE reporting the problem.


...................................................................................................................................................................................................

3 From the System Alarm window in the network manager, select Node B or RNC for
which the alarm has been reported and perform an alarm synchronization (Sync NE
Alarms).
...................................................................................................................................................................................................

4 If the problem has been solved, manually clear the alarm.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
14-30 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance
procedures

Unable to automatically delete PM data from NE


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when the
PM result files cannot be deleted from the NE.

Description
This alarm is only applicable when the OMC is designed to delete the PM result files
on the NE after the successfully retrievals.

Severity
WARNING

Probable cause
Remote node transmission error

System impact
The OMC may collect the same PM result file twice. There is no direct impact on the
OMC, but other management systems that process the performance management may
be lacking input.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 Manually clear the alarm.


...................................................................................................................................................................................................

2 If problem persists, contact the system administrator.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-31
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Unable to automatically retrieve PM data from NE


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when the
PM result files cannot be retrieved from certain NEs.

Description
Unable to automatically retrieve the PM data from the indicated network element.

Severity
WARNING

Probable cause
Remote node transmission error.

System impact
There is no direct impact on the OMC, but other management systems that process the
performance management may be lacking input.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

To clear alarm
...................................................................................................................................................................................................

1 At the OMC-UPS, verify if there are alarms that indicate that there are communication
problems with the NE.
...................................................................................................................................................................................................

2 If the error is reported ... then...


once go to Step 3.
repeatedly go to Step 5.

...................................................................................................................................................................................................................................
14-32 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Unable to automatically retrieve PM data from NE
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, startup and FTP or SFTP session to the NE for which the problem
has been reported and manually download the missing measurements to the OMC-UPS.
...................................................................................................................................................................................................

4 If the PM files are automatically forwarded to the NMS, a manual FTP session should
be started to upload the missing PM files to the NMS.
...................................................................................................................................................................................................

5 At the OMC, verify if the FTP address, FTP port number, directory, user name and
password match the data programmed on the failing NE.
...................................................................................................................................................................................................

6 At the OMC server, ping the FTP address to determine if there are possible network
problems.
...................................................................................................................................................................................................

7 At the OMC server, manually FTP to the NE using the same IP address, same login
and password an to the same directory.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-33
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Unmanaged state set to NE


...................................................................................................................................................................................................................................

Purpose
This procedure provides instructions for clearing the fault that was caused when a NE
state was set to unmanaged.

Description
The state of the NE is set to unmanaged. In the unmanaged state, the NE continues to
provide service but the communication between management system and the NE is
stopped. The communication can be restored whenever needed.

Severity
WARNING

Probable cause
The network element has been changed into unmanaged state.

System impact
• The OMC closes the connection with the NE. This implies that the operator will be
unable to perform any operation on the NE or to receive any notification from it.
• Loss of communication to the NE and corrupt data. Any operation that implies
communication with the NE will be rejected. The alarms shown for this NE may
not represent the current alarm status.
• Technician maintenance requests from the OMC-UPS will not be send to the NE.
• The system will reflect the last known state of the system before the
communication was lost.

Related information
There is no related information for this procedure.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
14-34 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - OMC alarm clearance Unmanaged state set to NE
procedures

To clear alarm
...................................................................................................................................................................................................

1 Change the unmanaged state to managed, so the NE can be registered again. A suspect
alarm cannot be cleared manually; however, the alarm will clear automatically once the
problem is fixed.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 14-35
Issue 1, August 2007 See notice on first page
Corrective maintenance - OMC alarm clearance
procedures

Remaining OMC alarm clearance procedures


...................................................................................................................................................................................................................................

Reference
Since the OMC alarm clearance procedures that are not listed in this chapter are
mainly related to OMC system alarms and not to the UTRAN, these fault clearance
procedures have been included in the:
Lucent OMC-UPS Operations, Administration, Maintenance, and Provisioning,
401-380-022 manual.

...................................................................................................................................................................................................................................
14-36 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
15 15
Corrective maintenance - Node
B alarm clearance procedures

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides the procedures to clear Node B alarms that are raised on the
OMC.

Related information
For more related information about this topic, refer to:
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
+24V, 401-382-462
• Lucent UMTS Modular Cell Outdoor, Operation, Administration and Maintenance
for +24V, 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
+24V, 401-382-961
• Lucent UMTS Microcell (Type M), Operation, Administration and Maintenance for
+24V, 401-382-966

Contents

General information 15-14


Object relationships 15-15
Node B fault recovery actions 15-16
Autonomous recovery actions taken by the Node B 15-20
Node B hardware replacement procedures 15-21
ALDController alarms 15-22
ALDController_communicationFailure 15-23
ALDController_hardwareFailure 15-25

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-1
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

ALDController_softwareDownloadFailure 15-27
ALDController_softwareFailure 15-29
ALDController_softwareVersionMismatch 15-31
ALDController_temperatureOutOfRange 15-33
ALDController_unknownDeviceDetected 15-35
AlarmHub alarms 15-37
AlarmHub_communicationFailure 15-38
AlarmHub_externalAlarmPort0 15-40
AlarmHub_externalAlarmPort1 15-42
AlarmHub_externalAlarmPort2 15-44
AlarmHub_externalAlarmPort3 15-46
AlarmHub_externalAlarmPort4 15-48
AlarmHub_externalAlarmPort5 15-50
AlarmHub_externalAlarmPort6 15-52
AlarmHub_externalAlarmPort7 15-54
AmpShelfFan alarms 15-56
AmpShelfFan_equipmentFault 15-57
CPC alarms 15-59
CPC_communicationFailure 15-60
CPC_configurationMismatch 15-62
CPC_dCOutputFailure 15-64
CPC_lowDCInput 15-66
CPC_overTemperature 15-68
CPRIPort alarms 15-70
CPRIPort_fibreLOF 15-71
CPRIPort_fibreLOS 15-72
CPRIPort_fibreRAI 15-73
CPRIPort_fibreSAPDefect 15-74
CPRIPort_fibreSigLow 15-75
CPRIPort_transmitterSwitchOff 15-76
CTU alarms 15-78
CTU_boardGenericMismatch 15-80

...................................................................................................................................................................................................................................
15-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

CTU_clockFailure15Mhz 15-82
CTU_clockFailure30_72Mhz 15-84
CTU_communicationFailure 15-86
CTU_configurationMismatch 15-88
CTU_flywheelStart 15-90
CTU_flywheelTimeLimitReached 15-92
CTU_frequencyOutOfRange 15-94
CTU_gPSAntennaFailure 15-96
CTU_gPSReceiverFailure 15-98
CTU_hardwareModelMismatch 15-100
CTU_inactive 15-102
CTU_initialisationFailure 15-104
CTU_lossOfClockSourceSynchronisation 15-106
CTU_maintenanceRequested 15-108
CTU_messageThrottleOn 15-110
CTU_noOMConfiguredInDatabase 15-112
CTU_phaseLockLoopFailure 15-114
CTU_selfTestFailure 15-116
CTU_syncSourceMismatch 15-118
CTU_temperatureOutOfRange 15-120
CTU_timeOfDayDataInvalid 15-122
CTU_underTemperature 15-124
CTU_waitingForClockSignal 15-126
Cell alarms 15-128
Cell_blockRequestTimerExpiry 15-129
Cell_configurationMismatch 15-131
Cell_powerTestThresholdExceeded 15-133
Cell_rETNotSupported 15-136
Cell_receiveAntennaTestThresholdExceededOnAllAntennas 15-138
Cell_receiveAntennaTestThresholdExceededOnAntenna1 15-140
Cell_receiveAntennaTestThresholdExceededOnAntenna2 15-142
Cell_temporarySoftwareFailure 15-144

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-3
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

DigitalShelfFan alarms 15-146


DigitalShelfFan_equipmentFault 15-147
E1T1Port alarms 15-149
E1T1Port_aISDetected 15-150
E1T1Port_atmSyncLost 15-152
E1T1Port_bitErrorRateGreaterThan1PerMillion 15-154
E1T1Port_bitErrorRateGreaterThan1PerThousand 15-156
E1T1Port_configurationMismatch 15-158
E1T1Port_frameLost 15-160
E1T1Port_frameMissed 15-162
E1T1Port_frameSlip 15-164
E1T1Port_iMALinkAlarm 15-166
E1T1port_localConfigurationFailure 15-168
E1T1Port_remoteAlarmIndication 15-170
E1T1Port_signalLost 15-172
E1T1Port_unexpectedIMAGroup 15-174
E3T3Port alarms 15-176
E3T3Port_linkFailureAIS 15-177
E3T3Port_linkFailureHBER 15-179
E3T3Port_linkFailureLBER 15-181
E3T3Port_linkFailureLOF 15-183
E3T3Port_linkFailureLOS 15-185
E3T3Port_linkFailureOOF 15-187
E3T3Port_linkFailureRDI 15-188
E3T3port_localConfigurationFailure 15-190
EthernetPort alarms 15-192
EthernetPort_portFailure 15-193
ExtRxAmp alarms 15-194
ExtRxAmp_configurationMismatch 15-195
ExtRxAmp_equipmentFault 15-197
ExtRxAmp_localConfigurationFailure 15-199
Filter alarms 15-201

...................................................................................................................................................................................................................................
15-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

Filter_communicationFailure 15-202
Filter_configurationMismatch 15-204
Filter_dCConverterFailure 15-206
Filter_hardwareModelMismatch 15-208
Filter_localConfigurationFailure 15-210
Filter_unknownHardwareModel 15-212
Frame alarms 15-214
Frame_cabinetDoorOpen 15-215
Frame_cabinetHeaterFailure 15-217
Frame_fanFault 15-219
Frame_heatManagementSystemCompressorFailure 15-221
Frame_heatManagementSystemControllerFailure 15-223
Frame_overTemperature 15-225
Frame_underTemperature 15-227
GRS alarms 15-229
GRS_configurationMismatch 15-230
GRS_firstPortNumberAlreadyInUse 15-232
GRS_gPSAntennaFailure 15-234
GRS_gPSAntennaPositionUnknown 15-236
GRS_gPSReceiverFailure 15-238
GRS_gPSReceiverUnavailable 15-240
GRS_satelliteHealthyThresholdExceededForAllVisibleSatellites 15-241
GRS_secondPortNumberAlreadyInUse 15-243
GRS_selfSurveyFailed 15-245
IMAGroup alarms 15-247
IMAGroup_criticalGroupAlarm 15-248
IMAGroup_criticalGroupConfigurationAlarm 15-250
IMAGroup_majorGroupAlarm 15-252
IMAGroup_noncriticalGroupConfigurationAlarm 15-254
IOU alarms 15-256
IOU_communicationFailure 15-258
IOU_externalAlarmPort0 15-260

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-5
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

IOU_externalAlarmPort1 15-262
IOU_externalAlarmPort10 15-264
IOU_externalAlarmPort11 15-266
IOU_externalAlarmPort12 15-268
IOU_externalAlarmPort13 15-270
IOU_externalAlarmPort14 15-272
IOU_externalAlarmPort15 15-274
IOU_externalAlarmPort16 15-276
IOU_externalAlarmPort17 15-278
IOU_externalAlarmPort18 15-280
IOU_externalAlarmPort19 15-282
IOU_externalAlarmPort2 15-284
IOU_externalAlarmPort20 15-286
IOU_externalAlarmPort21 15-288
IOU_externalAlarmPort22 15-290
IOU_externalAlarmPort23 15-292
IOU_externalAlarmPort24 15-294
IOU_externalAlarmPort25 15-296
IOU_externalAlarmPort26 15-298
IOU_externalAlarmPort27 15-300
IOU_externalAlarmPort28 15-302
IOU_externalAlarmPort29 15-304
IOU_externalAlarmPort3 15-306
IOU_externalAlarmPort30 15-308
IOU_externalAlarmPort31 15-310
IOU_externalAlarmPort4 15-312
IOU_externalAlarmPort5 15-314
IOU_externalAlarmPort6 15-316
IOU_externalAlarmPort7 15-318
IOU_externalAlarmPort8 15-320
IOU_externalAlarmPort9 15-322
Iub interface alarms 15-324

...................................................................................................................................................................................................................................
15-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

IubInterface_rNCCommunicationLost 15-325
NodeB alarms 15-327
NodeB_alarmDefFileCorrupt 15-328
NodeB_alarmDefFileMissing 15-330
NodeB_databaseCleared 15-332
NodeB_databaseRestoredFromSnapshot 15-335
NodeB_filesystemNearingCapacity 15-337
NodeB_filesystemObjectCorrupt 15-339
NodeB_invalidSecurityDataDetected 15-341
NodeB_ipfwNatRulesAltered 15-343
NodeB_nodeBTypeMismatch 15-345
NodeB_snapshotFailed 15-347
NodeB_unauthorizedLoginAttempt 15-349
NodeB_userPasswordLoginAttempt 15-351
OCM alarms 15-353
OCM_boardGenericMismatch 15-354
OCM_clockFailure30_72MHz 15-356
OCM_communicationFailure 15-357
OCM_initialisationFailure 15-359
OCM_lossOfForwardBusLink 15-360
OCM_lossOfPulse 15-361
OCM_missingconfigurationData 15-362
OCM_selfTestFailure 15-364
OM alarms 15-365
OM_clockFailure15Mhz 15-366
OM_configurationMismatch 15-368
OM_frequencyOutOfRange 15-370
OM_hardwareModelMismatch 15-372
OM_inactive 15-375
OM_maintenanceRequested 15-377
OM_phaseLockLoopFailure 15-380
OM_temperatureOutOfRange 15-382

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-7
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

OM_underTemperature 15-384
RETActuator alarms 15-386
RETActuator_actuatorJam 15-387
RETActuator_calibrationLost 15-389
RETActuator_communicationFailure 15-391
RETActuator_deviceTypeMismatch 15-393
RETActuator_hardwareFailure 15-394
RETActuator_positionLost 15-396
RETActuator_softwareFailure 15-398
RETActuator_tiltAngleOutOfRange 15-400
RFHead alarms 15-402
RFHead_boardGenericMismatch 15-404
RFHead_clockFailure 15-406
RFHead_communicationFailure 15-407
RFHead_criticalTransmitterAlarm 15-409
RFHead_dCInputFailure 15-411
RFHead_diversityImbalance 15-412
RFHead_externalAlarmPort0 15-414
RFHead_externalAlarmPort1 15-415
RFHead_externalAlarmPort2 15-416
RFHead_externalAlarmPort3 15-417
RFHead_externalAlarmPort4 15-418
RFHead_externalAlarmPort5 15-419
RFHead_fibreLOF 15-420
RFHead_fibreLOS 15-422
RFHead_fibreRAI 15-424
RFHead_fibreSAPDefect 15-426
RFHead_fibreSigLow 15-428
RFHead_initialisationFailure 15-430
RFHead_noncriticalTransmitterAlarm 15-431
RFHead_overTemperature 15-433
RFHead_rFOverdrive 15-435

...................................................................................................................................................................................................................................
15-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

RFHead_receiver1Failure 15-436
RFHead_receiver2Failure 15-437
RFHead_receiverFailure 15-438
RFHead_selfTestFailure 15-439
RFHead_softwareFailure 15-440
RFHead_temperatureOutOfRange 15-441
RFHead_txActivationFailure 15-443
RFHead_underTemperature 15-444
RFHead_vSWRAlarm 15-445
RFHead_warmup 15-446
Radio alarms 15-447
Radio_applicationInsane 15-449
Radio_boardGenericMismatch 15-450
Radio_clockFailure30_72Mhz 15-452
Radio_communicationFailure 15-455
Radio_configurationMismatch 15-457
Radio_criticalGainFailure 15-459
Radio_digitalClippingDetected 15-461
Radio_diversityImbalance 15-463
Radio_fPGAFailure 15-465
Radio_filterPanelRecordInvalid 15-467
Radio_hardwareModelMismatch 15-469
Radio_hwErrorDetectedByPlatformSw 15-471
Radio_initialisationFailure 15-473
Radio_internalGainFailure 15-475
Radio_localConfigurationFailure 15-477
Radio_lossOfDemodulatorSynthesizerSynchronisation 15-479
Radio_lossOfForwardBusLink 15-482
Radio_lossOfModulatorSynthesizerSynchronisation 15-484
Radio_lossOfPulse 15-487
Radio_lossOfReceiveSynthesizerSynchronisation 15-490
Radio_lossOfTransmitSynthesizerSynchronisation 15-493

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-9
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

Radio_majorGainFailure 15-496
Radio_majorPlatformSwError 15-499
Radio_majorTxSpectrumFailure 15-500
Radio_messageThrottleOn 15-503
Radio_minorGainFailure 15-505
Radio_missingConfigurationData 15-508
Radio_missingDelayCalibrationData 15-510
Radio_overTemperature 15-512
Radio_portMapInvalid 15-514
Radio_rFOverdrive 15-516
Radio_rFPathMismatch 15-518
Radio_resyncOfPulse 15-520
Radio_rx1PathFaultDetected 15-523
Radio_rx2PathFaultDetected 15-525
Radio_samplingReceiverFailure 15-527
Radio_selfTestFailure 15-529
Radio_synthesizerFailure122Mhz 15-531
Radio_synthesizerFailure15Mhz 15-533
Radio_tDUCommunicationFailure 15-535
Radio_toneGeneratorFailure 15-537
Radio_transmitGainLimitExceeded 15-539
Radio_transmitterSwitchFailure 15-542
Radio_transmitterSwitchOff 15-544
Radio_txActivationMalfunction 15-546
Radio_underTemperature 15-548
RxAmp alarms 15-550
RxAmp_equipmentFault 15-551
RxAmp_initialisationFailure 15-553
STM1OC3Port alarms 15-555
STM1OC3Port_linkFailureAIS_L 15-556
STM1OC3Port_linkFailureAIS_P 15-558
STM1OC3Port_linkFailureLOF 15-560

...................................................................................................................................................................................................................................
15-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

STM1OC3Port_linkFailureLOP_P 15-562
STM1OC3Port_linkFailureLOS 15-564
STM1OC3Port_linkFailurePLM_P 15-566
STM1OC3Port_linkFailureRDI_L 15-568
STM1OC3Port_linkFailureRDI_P 15-570
STM1OC3Port_linkFailureSLU_P 15-572
STM1OC3port_localConfigurationFailure 15-574
STM1OC3Port_pathTraceMismatch 15-576
STM1OC3Port_signalDegraded_L 15-578
STM1OC3Port_signalDegraded_P 15-580
STM1OC3Port_signalFailed_L 15-582
STM1OC3Port_signalFailed_P 15-584
TDU alarms 15-586
TDU_applicationInsane 15-587
TDU_boardGenericMismatch 15-589
TDU_communicationFailure 15-591
TDU_configurationMismatch 15-593
TDU_criticalVoltageFailure 15-595
TDU_filterPanelRecordInvalid 15-597
TDU_frequencySynthesizerFailure 15-599
TDU_heaterFailure 15-601
TDU_hwErrorDetectedByPlatformSw 15-603
TDU_initialisationFailure 15-605
TDU_localConfigurationFailure 15-607
TDU_lossOfPulse 15-609
TDU_majorPlatformSwError 15-612
TDU_messageThrottleOn 15-614
TDU_portMapInvalid 15-616
TDU_selfTestFailure 15-618
TDU_temperatureOutOfRange 15-620
TDU_tssiDetectorFailure 15-622
TxAmp alarms 15-624

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-11
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

TxAmp_amplifierSwitchFailure 15-625
TxAmp_communicationFailure 15-627
TxAmp_configurationMismatch 15-629
TxAmp_equipmentFault 15-631
TxAmp_externalAmplifierFailure 15-633
TxAmp_hardwareModelMismatch 15-635
TxAmp_incompletePredistortionCoefficients 15-637
TxAmp_initialisationFailure 15-639
TxAmp_localConfigurationFailure 15-641
TxAmp_messageThrottleOn 15-643
TxAmp_missingPredistortionCoefficients 15-645
TxAmp_overTemperature 15-647
TxAmp_rFOverdrive 15-649
TxAmp_selfTestFailure 15-651
TxAmp_severeExternalAmplifierFailure 15-653
TxAmp_underTemperature 15-655
TxAmp_warmupFailure 15-657
UCU alarms 15-659
UCU_applicationInsane 15-660
UCU_clockFailure30_72Mhz 15-662
UCU_combinerToASICBusFailure 15-664
UCU_communicationFailure 15-666
UCU_configurationMismatch 15-668
UCU_criticalChannelElementFailure 15-670
UCU_criticalChannelElementSystemResourceFailure 15-672
UCU_excessiveDownlinkParityErrors 15-674
UCU_excessiveUplinkParityErrors 15-676
UCU_fPGAFailure 15-678
UCU_hwErrorDetectedByPlatformSw 15-681
UCU_initialisationFailure 15-683
UCU_lossOfForwardBusLink 15-685
UCU_majorChannelElementSystemResourceFailure 15-687

...................................................................................................................................................................................................................................
15-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

UCU_majorPlatformSwError 15-689
UCU_selfTestFailure 15-691
UCU_voltageOutOfRange 15-693
UCU_watchdogInitiatedReset 15-695
URC alarms 15-697
URC_aTMOutOfCellDelineation 15-698
URC_applicationInsane 15-700
URC_clockFailure30_72Mhz 15-701
URC_configurationMismatch 15-703
URC_hardwareModelMismatch 15-705
URC_hwErrorDetectedByPlatformSw 15-707
URC_localConfigurationFailure 15-709
URC_lossOfPulse 15-711
URC_majorPlatformSwError 15-713

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-13
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

General information

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides general information on how the Node B handles hardware and
software faults.

Contents

Object relationships 15-15


Node B fault recovery actions 15-16
Autonomous recovery actions taken by the Node B 15-20
Node B hardware replacement procedures 15-21

...................................................................................................................................................................................................................................
15-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Object relationships
...................................................................................................................................................................................................................................

Managed objects
The Node B is a collection of Managed Objects (MO). When an MO detects an error
condition and sends an alarm to the OMC-UPS which is not only informational, the
system will perform an autonomous recovery action.

Dependencies
Some MOs such as radios, UCUs, TDUs depend on other MOs, e.g. a Radio MO
depends on the CTU MO. So when the CTU MO is disabled because it detects an
error condition, the Radio MO will also be disabled.
If a number of alarms for different MOs are sent to the OMC, the operator should
proceed as follows:
1. Find and analyse the oldest alarm (timestamp)
2. Perform the fault clearance procedure defined for it.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-15
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Node B fault recovery actions


...................................................................................................................................................................................................................................

Purpose
This topic describes alarm recovery actions that are taken when a fault occurs in the
Node B hardware or software.

Fault recovery process flow


The process flow illustrating the fault recovery actions:

...................................................................................................................................................................................................................................
15-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Node B fault recovery actions
procedures

Alarm occurs

Report alarm

Autonomous Y
recovery action
performed?

Re-
N
Isolate N initialization N
unit? threshold
reached?
Re-initialize unit
Y Y

Isolate unit

Operator performs
fault clearance procedure

N Fault
cleared?

Is
alarm of N Operator
ADAC clears alarm
Nature?

Automatically
clear alarm

End

Report the alarm


When a fault occurs in a Node B hardware or software unit, the fault is reported to the
Fault Management (FM) software in the Node B.
After receiving this fault indication, the FM software reports the appropriate alarm to
the OMC.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-17
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Node B fault recovery actions
procedures

The FM logs alarms locally in the historical alarm logfile which is stored in the RAM.
These alarms can be viewed via ftp (one file per day and one summary file
“NODEB.ALARM”). The Node B RMT provides access to the historical alarm logfiles
via the “FTP Agent” screen. When the Node B is reset, the historical alarm logfile is
empty.

Possible alarm recovery actions


Depending on the seriousness of the fault and the type of unit on which the fault has
been reported, the FM software can take the following recovery actions to solve the
fault:
• Reset and reinitialize the unit
• Isolate the unit.

Automatically reinitialize
The unit is reset and reinitialized automatically by the NodeB as local fault defense.
Note: If the fault occurs again, this local fault defense is repeated, if the reinitialization
threshold hasn’t been reached (6 reinitializations within 1 hour). If the threshold has
been reached, the unit is isolated

Isolate unit
If the unit has a severe fault or the reinitialization threshold has reached, the unit is
isolated, which means that it is reset, but not reinitialized. The operator must trigger a
reset action of the unit, so that the unit leaves the isolate state.

Perform fault clearance procedure


The operator must perform the fault clearance procedures for the unit when:
• The unit automatically performed reset and reinitialization, but the fault hasn’t been
cleared and so the alarm is reported again
• The unit has been moved to isolate (i.e. alarm is pending stable)
• The alarm is not cleared within an appropriate amount of time.
• The alarm is not cleared automatically (ADMC alarm)

Clearing alarms

If... then...
the fault has been cleared but the MO an additional alarm is raised, the MO is
fails to successfully reset and initialize, isolated (MO dependent) and the initial
alarm will still be pending.

....................................................................................................................................................................................................................................
15-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Node B fault recovery actions
procedures

If... then...
the fault has been cleared and the MO an alarm clear message is forwarded to
ssuccessfully resets and initializes, the OMC to remove the alarm from the
active alarm list.1

Notes:
1. If after a short time frame (depends on the MO), the fault is triggered again in the Node
B, the MO will be reset (an alarm will be triggered for during the reset period). If the
fault occurs more than six times within the next hour, the MO will become isolated and
the triggered alarm will remain active.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-19
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Autonomous recovery actions taken by the Node B


...................................................................................................................................................................................................................................

Overview
This topic describes the autonomous actions that are taken by the Node B whenever
the Node B is internally reset.

Autonomous recovery
When a severe fault occurs, the Node B is autonomously reset.
When a URC is reset, the loss of communication with the Node B will be indicated by
an RNC alarm at the OMC.

Node B status during autonomous recovery


When a URC is reset, the OMC looses communication with the Node B.
During the reset, the status of the Node B is not clear to the OMC operator until the
reset is successfully completed and the connection to the OMC is reestablished.

Failing URC
The following actions are taken after a severe fault has been detected in the URC:

Action Result Expected


recovery time
The Node B will be reset. The cells that are related to this < 5 min1
Node B are not operational until all
main units of the Node B have
returned to the operational state.

Notes:
1. If the URC software restarted successfully.

...................................................................................................................................................................................................................................
15-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Node B hardware replacement procedures


...................................................................................................................................................................................................................................

Node B hardware replacement


If hardware must be replaced, the fault clearance procedure lists the following steps:
1. At the OMC, lock <object-name>
2. At the <NE>, replace <hardware>
3. At the OMC, reset the <object-name>
4. At the OMC, unlock <object-name>.
These fault clearance procedure steps are not intended as an exact step-by-step
procedure, but only as an high level overview.
The exact steps in the procedure to replace hardware are described in “Fault
Management”, chapter “Corrective maintenance - fault correction” of the Node B
OA&M manual.
The chapter describes the detailed step-by-step procedures and includes additional
information, such as safety warnings and required tools.

Related Node B OAM manuals


For the procedures to replace Node B hardware, refer to:
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
-48 V, 401-382-460
• Lucent UMTS Macrocell Indoor, Operation, Administration and Maintenance for
+24 V, 401-382-462
• Lucent UMTS Macrocell Integrated, Operation, Administration and Maintenance
for -48 V, 401-382-660
• Lucent UMTS Modular Cell Outdoor, Operation, Administration and Maintenance
for +24 V, 401-382-760
• Lucent UMTS Macrocell Compact, Operation, Administration and Maintenance for
-48 V, 401-382-960

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-21
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

ALDController alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the ALD Controller alarms.

Contents

ALDController_communicationFailure 15-23
ALDController_hardwareFailure 15-25
ALDController_softwareDownloadFailure 15-27
ALDController_softwareFailure 15-29
ALDController_softwareVersionMismatch 15-31
ALDController_temperatureOutOfRange 15-33
ALDController_unknownDeviceDetected 15-35

...................................................................................................................................................................................................................................
15-22 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_communication-
Failure alarm.

Description
The communication to the ALD Controller cannot be established or has been lost.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible root causes:
• Cabling problem
• Equipment failure
• Equipment not installed

System impact
ALD system not operational. NodeB cyclicly tries to reconnect.No impact on call
processing.

Automatic corrective actions


FM triggers state change to failed. CM cyclicly tries to connect to ALD Controller.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait several minutes for automatic clearance of the alarm.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-23
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_communicationFailure
procedures

...................................................................................................................................................................................................

2 At the Node B, check cabling between NodeB and ALD Controller.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the NodeB, replace ALD Controller.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-24 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_hardwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_hardwareFailure
alarm.

Description
A hardware failure has occured on the ALD Controller.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The ALD Controller is reset and reinitialized autonomously. During that time the ALD
system is not operational. No impact on call processing.

Automatic corrective actions


FM triggers (soft) reset and reinitialization of the ALD Controller.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the ALD Controller reinitialization is completed.


If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the ALDController object, which leads to a hard reset of the
ALD Controller.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-25
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_hardwareFailure
procedures

If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

3 At the NodeB, replace the ALD Controller.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-26 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_softwareDownloadFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_softwareDown-
loadFailure alarm.

Description
Software download to the ALD Controller has failed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Possible root causes:
• Communication problem
• Equipment failure
• Corrupted file

System impact
ALD system not operational. No impact on call processing.

Automatic corrective actions


FM triggers state change to failed.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for communicationFailure alarm of ALDController object and


perform the fault clearance procedure for that alarm.
If that alarm has been cleared, the download is started again automatically.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-27
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_softwareDownloadFailure
procedures

If the download has been completed successfully, the procedure is completed.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the ALDController object to start the download again.
If the download has been completed successfully, the procedure is completed.
...................................................................................................................................................................................................

3 At the NodeB, replace the ALD Controller.


The download is started again automatically, if required.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-28 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_softwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_softwareFailure
alarm.

Description
A software failure has occured on the ALD Controller.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Software error.

System impact
The ALD Controller is reset and re-initialized autonomously. During that time the ALD
system is not operational. No impact on call processing.

Automatic corrective actions


FM triggers (soft) reset and reinitialization of the ALD Controller.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the ALD Controller reinitialization is completed.


If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the ALDController object, which leads to a hard reset of the
ALD Controller.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-29
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_softwareFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-30 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_softwareVersionMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_softwareVersion-
Mismatch alarm.

Description
The software version on the ALD Controller does not match the current NodeB
software version.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Software version mismatch during initial NodeB startup or NodeB upgrade or
downgrade.

System impact
ALD system not operational.No impact on call processing.

Automatic corrective actions


NodeB autonomously performs the download and activation of ALD Controller
software.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until completion of download (may take up to 2 hours).The


alarm is cleared automatically in case of successful download and activation.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-31
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_softwareVersionMismatch
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for softwareDownloadFailure alarm of ALDController object


and perform the fault clearance procedure for that alarm.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-32 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_temperatureOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_temperature-
OutOfRange alarm.

Description
The temperature of the ALD Controller has exceeded the specified upper or lower
limit.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
low or high temperature.

System impact
The ALD Controller remains operational, but may fail at any time as it is operating
outside the guaranteed environmental conditions. If the ALD Controller is reset, it will
not come up until the temperature is again within acceptable limits.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Frame alarms related to heat management system or fan
problems, and perform the fault clearance procedure for the alarms.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-33
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_temperatureOutOfRange
procedures

...................................................................................................................................................................................................

2 At the NodeB, check environment of the ALD Controller for unacceptable temperature
and repair fan / heat management system as appropriate.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-34 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ALDController_unknownDeviceDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ALDController_unknownDeviceDe-
tected alarm.

Description
Unknown antenna line device detected.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
One or more antenna line devices are not configured in the backplane of the NodeB.

System impact
Unknown antenna line device is not used.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS or NodeB, check configuration of the ALD system in the backplane
of the NodeB via (remote) RMT
...................................................................................................................................................................................................

2 Important! Backplane configuration update has service impact on the Node B


At the OMC-UPS or NodeB, update configuration if required via (remote) RMT

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-35
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ALDController_unknownDeviceDetected
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-36 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Alarm Hub alarms.

Contents

AlarmHub_communicationFailure 15-38
AlarmHub_externalAlarmPort0 15-40
AlarmHub_externalAlarmPort1 15-42
AlarmHub_externalAlarmPort2 15-44
AlarmHub_externalAlarmPort3 15-46
AlarmHub_externalAlarmPort4 15-48
AlarmHub_externalAlarmPort5 15-50
AlarmHub_externalAlarmPort6 15-52
AlarmHub_externalAlarmPort7 15-54

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-37
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_communicationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_communicationFailure
alarm.

Description
Heartbeat synchronisation between the Alarm Hub and the URC has been lost.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-38 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_communicationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-39
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort0
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort0
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-40 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort0
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-41
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort1
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort1
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-42 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort1
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-43
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort2
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort2
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-44 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort2
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-45
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort3
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort3
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-46 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort3
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-47
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort4
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort4
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-48 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort4
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-49
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort5
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort5
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-50 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort5
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-51
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort6
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort6
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-52 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort6
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-53
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AlarmHub_externalAlarmPort7
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not supported in this release.
This topic provides the procedure for clearing the AlarmHub_externalAlarmPort7
alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA

...................................................................................................................................................................................................................................
15-54 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance AlarmHub_externalAlarmPort7
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-55
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

AmpShelfFan alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the amplifier shelf fan.

Contents

AmpShelfFan_equipmentFault 15-57

...................................................................................................................................................................................................................................
15-56 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

AmpShelfFan_equipmentFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the AmpShelfFan_equipmentFault alarm.

Description
The fan in the Amplifier Shelf failed.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment malfunction.

System impact
The system will be impacted as indicated below:
• The shelf temperature will rise causing over-temperature alarms on the boards if the
alarm is pending and the operational state of the DigitalShelfFan MO is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
• Over temperature alarms result in shutdown of boards and dropped calls on the
Node B.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, replace the fan tray.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-57
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance AmpShelfFan_equipmentFault
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-58 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

CPC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Common Power Converter
(CPC).

Contents

CPC_communicationFailure 15-60
CPC_configurationMismatch 15-62
CPC_dCOutputFailure 15-64
CPC_lowDCInput 15-66
CPC_overTemperature 15-68

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-59
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPC_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CPC_communicationFailure alarm.

Description
Heartbeat synchronization between the CPC (Common Power Converter) and the URC
(Universal Radio Controller) has been lost.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.

System impact
The system will be impacted as indicated below:
• The call capacity of the whole Node B is reduced, if the alarm is pending and the
operational state of the CPC MO is disabled.
• If too many boards fail, the Node B can no longer operate.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
Note: There are two types of CPCs, an A type and a B type, which deliver different
voltages. At least one instance of each type is needed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-60 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPC_communicationFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check whether the CPC is mounted correctly into the shelf.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, check the power cabling.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, replace the CPC.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-61
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPC_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CPC_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
15-62 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPC_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-63
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPC_dCOutputFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CPC_dCOutputFailure alarm.

Description
A DC output failure at the CPC (Common Power Converter) has been detected.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment malfunction.

System impact
The system will be impacted as indicated below:
• The call capacity of the whole Node B is reduced, if the alarm is pending and the
operational state of the CPC MO is disabled.
• If too many boards fail, the Node B can no longer operate.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
Note: There are two types of CPCs, an A type and a B type, which deliver different
voltages. At least one instance of each type is needed.

Automatic corrective actions


None

Before you begin


No additional information is is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, replace the CPC.


...................................................................................................................................................................................................................................
15-64 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPC_dCOutputFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-65
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPC_lowDCInput
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CPC_lowDCInput alarm.

Description
A low DC input power on the CPC (Common Power Converter) is detected.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Power problem.

System impact
The system will be impacted as indicated below:
• The call capacity of the whole Node B is reduced, if the alarm is pending and the
operational state of the CPC MO is disabled.
• If too many boards fail, the Node B can no longer operate.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
Note: There are two types of CPCs, an A type and a B type, which deliver different
voltages. At least one instance of each type is needed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check the power cabling.


...................................................................................................................................................................................................................................
15-66 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPC_lowDCInput
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the Node B, ensure that the DC input voltage is not too low.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, check the outdoor site DC input voltage. Replace any battery that runs
low.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the Node B, replace the CPC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-67
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPC_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CPC_overTemperature alarm.

Description
The CPC (Common Power Converter) reports that the temperature is above the
specified limit.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
The temperature of the CPC is unacceptable.

System impact
The system will be impacted as indicated below:
• The call capacity of the whole Node B is reduced, if the alarm is pending and the
operational state of the CPC MO is disabled.
• If too many boards fail, the Node B can no longer operate.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
Note: There are two types of CPCs, an A type and a B type, which deliver different
voltages. At least one instance of each type is needed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-68 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPC_overTemperature
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, clear any cooling problems.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, clear any fan failures.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, replace the CPC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-69
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the CPRIPort alarms.

Contents

CPRIPort_fibreLOF 15-71
CPRIPort_fibreLOS 15-72
CPRIPort_fibreRAI 15-73
CPRIPort_fibreSAPDefect 15-74
CPRIPort_fibreSigLow 15-75
CPRIPort_transmitterSwitchOff 15-76

...................................................................................................................................................................................................................................
15-70 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_fibreLOF
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_fibreLOF alarm.

Description
The fibre interface has encountered a loss of frame.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-71
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_fibreLOS
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_fibreLOS alarm.

Description
The fibre interface has encountered a loss of signal.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Personnel must take corrective action to fix loss of signal.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-72 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_fibreRAI
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_fibreRAI alarm.

Description
The fibre interface has encountered a remote alarm indication.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-73
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_fibreSAPDefect
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_fibreSAPDefect alarm.

Description
The fibre interface has encountered a service access point (SAP) defect.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-74 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_fibreSigLow
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_fibreSigLow alarm.

Description
The fibre interface has encountered a low optical signal.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
TBA

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-75
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CPRIPort_transmitterSwitchOff
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the CPRIPort_transmitterSwitchOff
alarm.

Description
The HW switch on the OCM faceplate is set to off. This turns off the transmit data
stream (ie downstream) of the user plane of the connected RF Heads.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
Equipment failure

System impact
TBA

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 TBA.

...................................................................................................................................................................................................................................
15-76 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CPRIPort_transmitterSwitchOff
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-77
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Common Timing Unit
(CTU).

Contents

CTU_boardGenericMismatch 15-80
CTU_clockFailure15Mhz 15-82
CTU_clockFailure30_72Mhz 15-84
CTU_communicationFailure 15-86
CTU_configurationMismatch 15-88
CTU_flywheelStart 15-90
CTU_flywheelTimeLimitReached 15-92
CTU_frequencyOutOfRange 15-94
CTU_gPSAntennaFailure 15-96
CTU_gPSReceiverFailure 15-98
CTU_hardwareModelMismatch 15-100
CTU_inactive 15-102
CTU_initialisationFailure 15-104
CTU_lossOfClockSourceSynchronisation 15-106
CTU_maintenanceRequested 15-108
CTU_messageThrottleOn 15-110
CTU_noOMConfiguredInDatabase 15-112
CTU_phaseLockLoopFailure 15-114
CTU_selfTestFailure 15-116
CTU_syncSourceMismatch 15-118
CTU_temperatureOutOfRange 15-120
CTU_timeOfDayDataInvalid 15-122
CTU_underTemperature 15-124

...................................................................................................................................................................................................................................
15-78 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

CTU_waitingForClockSignal 15-126

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-79
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_boardGenericMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_boardGenericMismatch alarm.

Description
The software version on the Common Timing Unit (CTU) does not match with the
current version stored on the URC because a software download failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The software on the CTU could not be updated because the download from the URC
to the CTU failed.

System impact
The CTU can not be initiated to service. No calls on this Node B are possible.

Automatic corrective actions


The CTU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, fallback to previous NodeB software if appropriate.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object to update the software on the CTU.
If the alarm is cleared, the procedure is completed

...................................................................................................................................................................................................................................
15-80 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_boardGenericMismatch
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, check the state of the current NodeB software version via RMT. If
the state is not GOOD, reset the NodeB object.
If the alarm is cleared, the procedure is completed.
Result: The NodeB automatically downloads missing/corrupted software files from
the FTP server (OMC) and updates the software on the CTU.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-81
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_clockFailure15Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_clockFailure15Mhz alarm.

Description
The Common Timing Unit (CTU) detected loss of the 15.0 Mhz clock. This may be
due to failure of OM onboard the CTU.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Call processing on the Node B is interrupted

Automatic corrective actions


The CTU is reset autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


The CTU and OM are reset and reinitialize autonomously. Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
...................................................................................................................................................................................................................................
15-82 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_clockFailure15Mhz
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

4 At the Node B, check the cabling between the CTU and I/O panel.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

7 At the Node B, replace the CTU.


...................................................................................................................................................................................................

8 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 If the problem persists, contact Lucent customer services.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-83
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_clockFailure30_72Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_clockFailure30_72Mhz alarm.

Description
The Common Timing Unit (CTU) failed to detect the 30.72 MHz clock signal.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Call processing on the Node B is interrupted. If a spare CTU is available, a
switch-over will occur.

Automatic corrective actions


The CTU and OM are reset and reinitialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, check the cabling between the Oscillator Module and the faceplate and
between the CTU and the faceplate.

...................................................................................................................................................................................................................................
15-84 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_clockFailure30_72Mhz
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU.


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-85
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_communicationFailure alarm.

Description
Heartbeat synchronization between the Common Timing Unit (CTU) and the Universal
Radio Controller (URC) has been lost or timeout occured during initialisation of the
CTU.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.

System impact
Call processing on the Node B is interrupted. If a spare CTU is available, a
switch-over will occur.

Automatic corrective actions


The CTU and OM are reset and reinitialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the CTU reinitialization is completed. If the alarm is not
cleared within 5 minutes, the initialisation has failed.
...................................................................................................................................................................................................................................
15-86 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_communicationFailure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the OMC-UPS, check for additional alarms, for example CTU_selfTestFailure or


CTU_initialisationFailure. Perform a lock, reset and unlock action in order to reset and
reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, make sure that the CTU is mounted properly in the shelf.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

6 At the Node B, replace the CTU.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-87
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
15-88 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-89
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_flywheelStart
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_flywheelStart alarm.

Description
Flywheeling start.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
The discipline source (network or GPS) has been lost in case of an crystal oscillator
(OM-Q).

System impact
The clock of the Node B will become unstable.
The CTU is allowed to flywheel for 72 hours. During this time period, there is no
impact on call processing. After 72 hours call processing will be disabled.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-90 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_flywheelStart
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Important! Avoid any maintenance activity which is not related to the flywheeling
and which would cause a reset and initialization of the CTU or the complete Node
B.

If... Then...
The discipline source = gps Go to step 2.
The discipline source = network Go to step 4.

...................................................................................................................................................................................................

2 At the Node B, make sure that the GPS antenna, the GPS antenna cable, receiver and
the clock splitter are working properly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

4 At the OMC-UPS, check for E1T1Port alarms and perform the fault clearance
procedure related to these alarms.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the Node B, check cabling.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-91
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_flywheelTimeLimitReached
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_flywheelTimeLimitReached
alarm.

Description
Flywheeling time limit reached.

Default severity
Critical

Alarm type
qualityofServiceAlarm

Root cause
The discipline source (network or GPS) is not available during initialisation of the
CTU with a crystal oscillator (OM-Q), or the CTU flywheeled for more than 72 hours.

System impact
RF part is shut down. No call processing is possible and all calls are dropped.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 If... Then...
The discipline source = gps Go to step 2.
The discipline source = network Go to step 5.

...................................................................................................................................................................................................................................
15-92 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_flywheelTimeLimitReached
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the GPS antenna, the GPS antenna cable, receiver and
the clock splitter are working properly.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

5 At the OMC-UPS, check for E1T1Port alarms and perform fault clearance procedure
related to these alarms.
...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the Node B, check the cabling.


...................................................................................................................................................................................................

8 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-93
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_frequencyOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_frequencyOutOfRange alarm.

Description
The frequency generated by the Oscillator Module (OM) onboard the CTU is out of
range

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure or network clock failure

System impact
Call processing may be impacted:
• Cells not available to the UE (sleeping cell)
• Handover not possible to cells of the affected NodeB
• Radio frequency being out of the assigned band

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, determine if the alarm occurs for single or multiple Node Bs.
...................................................................................................................................................................................................

2 In the case of multiple Node Bs being affected, check and repair the network clock

...................................................................................................................................................................................................................................
15-94 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_frequencyOutOfRange
procedures

...................................................................................................................................................................................................

3 In the case of a single Node B being affected, replace the CTU.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-95
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_gPSAntennaFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_gPSAntennaFailure alarm.

Description
The Global Positioning System (GPS) receiver detected that the GPS antenna or the
antenna cable is broken.
Important! This alarm only applies if the syncSource attribute of the NodeB object
is set to ″internalGPS″

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Antenna problem.

System impact
Call processing on the Node B is interrupted.
If a spare CTU is available, a switch-over will occur.

Automatic corrective actions


The clock is turned off, when the alarm is raised.
The clock is turned on, when the alarm is cleared.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the GPS antenna and the GPS antenna cable are
working properly.

...................................................................................................................................................................................................................................
15-96 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_gPSAntennaFailure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

3 At the Node B, replace the CTU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-97
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_gPSReceiverFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_gPSReceiverFailure alarm.

Description
The Common Timing Unit (CTU) detected a Global Positioning System (GPS) receiver
failure.
Important! This alarm only applies if the syncSource attribute of the NodeB object
is set to ″internalGPS″

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Call processing on the Node B is interrupted.
If a spare CTU is available, a switch-over will occur.

Automatic corrective actions


The clock is turned off, when the alarm is raised.
The clock is turned on, when the alarm is cleared.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the GPS antenna, the GPS antenna cable, receiver, and
the clock splitter are working properly.

...................................................................................................................................................................................................................................
15-98 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_gPSReceiverFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

3 At the Node B, replace the CTU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-99
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_hardwareModelMismatch
alarm.

Description
The detected hardware model does not match the value specified

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedCTUHardwareModel Go to step 2.
is incorrect,

...................................................................................................................................................................................................................................
15-100 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_hardwareModelMismatch
procedures

If ... then ...


an install of the correct hardware model is Go to step 7.
required,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

8 At the Node B, replace the CTU.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-101
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_inactive
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_inactive alarm.

Description
The OM onboard the CTU is not operational.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Call processing on the Node B is interrupted

Automatic corrective actions


The CTU is reset autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-102 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_inactive
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Lucent customer services.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-103
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_initialisationFailure alarm.

Description
The Common Timing Unit (CTU) failed to initialize, due to a failure during Board
Level Self Test (BLST), reset or enable.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The CTU cannot be initialized to service. If no spare CTU is available, then the Node
B cannot be brought to service. If a spare is available, then the spare CTU is activated.

Automatic corrective actions


The CTU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-104 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_initialisationFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-105
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_lossOfClockSourceSynchronisation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_lossOfClockSourceSynchro-
nisation alarm.

Description
The Common Timing Unit (CTU) cannot detect the 8 kHz E1 synchronization signal
from the E1 link.
Note: This alarm only applies when the syncSource attribute of the NodeB object is
set to network.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Calls might drop if the clock signal remains unstable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for E1T1Port alarms and perform fault clearance procedure
related to these alarms.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-106 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_lossOfClockSourceSynchronisation
procedures

...................................................................................................................................................................................................

2 Switch over to another synchronization source.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-107
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_maintenanceRequested
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_maintenanceRequested alarm.

Description
The OM onboard the CTU is indicating that it can no longer compensate for frequency
shifts.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
OM frequency can no longer be adjusted.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the CTU object to reset the CTU board.
Use the reset type type0 to trigger a software reset.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object to reset the CTU board.
Use the reset type type1 to trigger a power cycle.
...................................................................................................................................................................................................................................
15-108 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_maintenanceRequested
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

6 At the Node B, replace the CTU.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Lucent customer services.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-109
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_messageThrottleOn
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_messageThrottleOn alarm.

Description
Message throttling has been activated because too many errors are being sent by the
Common Timing Unit (CTU).

Default severity
Critical

Alarm type
qualityofServiceAlarm

Root cause
System resources are at or are near maximum capacity. Too many errors have occurred
in a given time frame.

System impact
Call processing on the Node B is interrupted. If there is a spare CTU, a switch-over
will occur.

Automatic corrective actions


The CTU and OM are reset and reinitialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for other CTU and OM alarms and perform fault clearance
procedures for the alarms.
...................................................................................................................................................................................................................................
15-110 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_messageThrottleOn
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-111
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_noOMConfiguredInDatabase
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_noOMConfiguredInDatabase
alarm.

Description
OM hardware is present, but it is not configured in the database. The CTU can not
initialize.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Configuration error.

System impact
The CTU can not initialize, call processing is blocked on the entire Node B.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, create the OM object.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-112 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_noOMConfiguredInDatabase
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-113
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_phaseLockLoopFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_phaseLockLoopFailure alarm.

Description
The phase lock on the OM onboard the CTU has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Call processing on the Node B is interrupted

Automatic corrective actions


The CTU is reset autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and initialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-114 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_phaseLockLoopFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-115
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_selfTestFailure alarm.

Description
The Common Timing Unit (CTU) failed the Board Level Self Test (BLST).

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
CTU cannot be initialized to service. If no spare CTU is available, the Node B cannot
be brought to service. If a spare CTU is available the spare CTU is activated.

Automatic corrective actions


The CTU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the CTU is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................................................
15-116 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_selfTestFailure
procedures

...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-117
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_syncSourceMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_syncSourceMismatch alarm.

Description
The available OM (separate board or integrated in CTU) does not fit to the configured
syncSource of the Node B.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The OM hardware does not fit to the configured syncSource. The CTU can not be
configured.

System impact
Call processing is blocked on the whole Node B.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for hardwareModelMismatch alarms of CTU and OM objects


and perform fault clearance procedure for them.
If the alarm is cleared together with the hardwareModelMismatch alarms, the
procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check if the NodeB syncSource attribute requires to be updated


...................................................................................................................................................................................................................................
15-118 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_syncSourceMismatch
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Node B object.


...................................................................................................................................................................................................

4 At the OMC-UPS, update the Node B syncSource attribute.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Node B object.


...................................................................................................................................................................................................

6 If the alarm persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-119
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_temperatureOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_temperatureOutOfRange alarm.

Description
The temperature of the OM onboard the CTU has exceeded the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Probable causes are:
• Defective heater on OM.
• Environmental temperature too high

System impact
Call processing on the Node B is interrupted

Automatic corrective actions


• The clock is turned off, when the alarm is raised.
• The clock is turned on, when the alarm is cleared.
• The CTU is isolated if the number of alarm occurences per hour reach a preset
threshold.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS check for Frame and DigitalShelfFan alarms and perform the fault
clearance procedure for these alarms.
If the temperatureOutOfRange alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-120 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_temperatureOutOfRange
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the system is operating within its operational
temperature.
If the temperatureOutOfRange alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the CTU, if the
temperatureOutOfRange alarm has been reported several times and so the CTU has
been isolated.
If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Lucent customer services.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-121
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_timeOfDayDataInvalid
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_timeOfDayDataInvalid alarm.

Description
The time of day data cannot be determined.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Timing problem.

System impact
Call processing on the Node B is interrupted. If there is a spare CTU, a switch-over
will occur.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the GPS antenna, the GPS antenna cable, receiver and
the clock splitter are working properly.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-122 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_timeOfDayDataInvalid
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-123
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_underTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_underTemperature alarm.

Description
The temperature of the OM onboard the CTU is below the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Probable causes are:
• Defective heater on OM.
• Environmental temperature too low.

System impact
Call processing on the Node B is interrupted

Automatic corrective actions


• The clock is turned off, when the alarm is raised.
• The clock is turned on, when the alarm is cleared.
• The OM is isolated if the number of alarm occurences per hour reach a preset
threshold

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps.
...................................................................................................................................................................................................

1 At the OMC-UPS check for Frame alarms and perform the fault clearance procedure
for these alarms.
If the underTemperature alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-124 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_underTemperature
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the system is operating within itsoperational
temperature.
If the underTemperature alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the CTU, if the
underTemperature alarm has been reported several times and so the CTU has been
isolated.
If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the CTU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Lucent customer services.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-125
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

CTU_waitingForClockSignal
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CTU_waitingForClockSignal alarm.

Description
The Common Timing Unit (CTU) is waiting for the clock signal to become stable.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
If the clock signal remains unstable calls might drop. The CTU and OM are reset and
reinitialize autonomously.
Note: In the startup phase this alarm is informational only, it should disappear after 15
minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-126 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance CTU_waitingForClockSignal
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the synchronization sources. At the OMC-U, reset the CTU
object to reset and reinitialize the CTU.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-127
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the Cell fault clearance procedures.

Contents

Cell_blockRequestTimerExpiry 15-129
Cell_configurationMismatch 15-131
Cell_powerTestThresholdExceeded 15-133
Cell_rETNotSupported 15-136
Cell_receiveAntennaTestThresholdExceededOnAllAntennas 15-138
Cell_receiveAntennaTestThresholdExceededOnAntenna1 15-140
Cell_receiveAntennaTestThresholdExceededOnAntenna2 15-142
Cell_temporarySoftwareFailure 15-144

...................................................................................................................................................................................................................................
15-128 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Cell_blockRequestTimerExpiry
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_blockRequestTimerExpiry
alarm.

Description
A block resource request message has been sent to the RNC. The RNC has failed to
respond even after the request was repeated.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Software failure.

System impact
There may be a mismatch between the state of the Cell at the NodeB and RNC.

Automatic corrective actions


The NodeB will put the Cell back to the unblocked state.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for any alarm of the related LCell and IuB objects of the
RNC and perform the fault clearance procedures for these alarms.
...................................................................................................................................................................................................

2 At the OMC-UPS, repeat the lock command, either for NodeB, URC or Radio object.
If the lock is successful, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-129
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Cell_blockRequestTimerExpiry
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object related to the Cell object.
...................................................................................................................................................................................................

4 At the OMC-UPS, repeat the lock command, either for NodeB, URC or Radio object.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-130 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Cell_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_configurationMismatch alarm.

Description
A consistency error between the MO data and its related port maps, Unit Type
Descriptor and/or hardware.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning, frequency band not supported by any Radio or RF-Head or
equipment failure.

System impact
No Service available in this cell.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the additionalText of the alarm.


If the additionalText indicates RF_EQUIP_CURRENTLY_UNKNOWN continue with step 2,
otherwise go to step 5.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the administrative state of the MO CTU. Unlock the MO
CTU, if required.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-131
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Cell_configurationMismatch
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the OMC-UPS, check for CTU & OM alarms and perform the fault clearance
procedure of these alarms.
If the configurationMismatch alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, check for Radio and/or RFHead alarms and perform the fault
clearance procedure of these alarms.
If the configurationMismatch alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-132 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Cell_powerTestThresholdExceeded
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_powerTestThresholdExceeded
alarm.

Description
A powerTest was executed and the carrier power test threshold has been exceeded.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Transmit failure.

System impact
Call capacity is degraded.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for TX path alarms (Radio and TxAmp objects) alarms and
perform fault clearance procedures for the alarms. Probably Radio_transmitGainLimit-
Exceeded is pending.
Then request another Power Test.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-133
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Cell_powerTestThresholdExceeded
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for TDU alarms and perform fault clearance procedures for
the alarms. Especially when powerTest alarms are reported form multiple cells, the
TDU could have a failure.
Then request another Power Test.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, make sure that the TX path (Filter, RF cabling and TX antenna) is
working properly.
Then request another Power Test.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the Node B:
• Lock the TxAmp object
• Replace the amplifier module
• Reset the TxAmp object
• Unlock the TxAmp object
Then request another Power Test.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the Node B:
• Lock the Radio object
• Replace the Radio
• Reset the Radio object
• Unlock the Radio object
Then request another Power Test.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the Node B:
• Lock the TDU object
• Replace the TDU
• Reset the TDU object
• Unlock the TDU object

....................................................................................................................................................................................................................................
15-134 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Cell_powerTestThresholdExceeded
procedures

Then request another Power Test.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-135
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell_rETNotSupported
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_rETNotSupported alarm.

Description
RET not supported, since at least one antenna, but not all antennas supporting this cell
have a RET actuator assigned.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
misconfiguration in backplane of NodeB.

System impact
ALD system not operational for the cell. No impact on call processing.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Important! Backplane configuration update has service impact on the Node B.


At the OMC-UPS or NodeB update the backplane configuration via (remote) RMT.

...................................................................................................................................................................................................................................
15-136 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Cell_rETNotSupported
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-137
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell_receiveAntennaTestThresholdExceededOnAllAntennas
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_receiveAntennaTestThresh-
oldExceededOnAllAntennas alarm.

Description
This alarm is generated when an Rx Antenna Test is executed and the threshold is
exceeded on all antennas. A failure indicates that the antenna is not functioning.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Receive failure.

System impact
Disfunction of all antennas to be expected.
Degradation of call capacity to be expected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for TDU alarms and perform fault clearance procedures for
the alarms. Then request another RX Antenna Test.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for Radio, TxAmp and Filter alarms and perform fault
clearance procedures for the alarms. Then request another RX Antenna Test.
...................................................................................................................................................................................................................................
15-138 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures Cell_receiveAntennaTestThresholdExceededOnAllAntennas

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the NodeB, make sure, that the RX path (Filter, RF cabling and RX antenna) is
working properly
If required replace the RX Antenna. Then request another RX Antenna Test
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the NodeB, replace the Filter panel. Then request another RX Antenna Test.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

6 At the NodeB, replace the TDU.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the TDU object


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the TDU object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-139
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell_receiveAntennaTestThresholdExceededOnAntenna1
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_receiveAntennaTestThresh-
oldExceededOnAntenna1 alarm.

Description
This alarm is generated when a RX Antenna Test is executed and the threshold is
exceeded on antenna 1.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Receive failure.

System impact
Disfunction of antenna 1 to be expected.
Minor degradation of call capacity to be expected.l

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for RxAmp and Filter alarms and perform fault clearance
procedures for the alarms.
Then request another RX Antenna Test.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-140 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Cell_receiveAntennaTestThresholdExceededOnAntenna1
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the RX path (Filter, RF cabling and RX antenna) is
working properly.
Replace RX antenna 1 if required.
...................................................................................................................................................................................................

3 At the OMC-UPS, request another RX Antenna Test.


If the alarm is cleared, the procedure is completed
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-141
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell_receiveAntennaTestThresholdExceededOnAntenna2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_receiveAntennaTestThresh-
oldExceededOnAntenna2 alarm.

Description
This alarm is generated when a RX Antenna Test is executed and the threshold is
exceeded on antenna 2.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Receive failure.

System impact
Disfunction of antenna 2 to be expected.
Minor degradation of call capacity to be expected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for RxAmp and Filter alarms and perform fault clearance
procedures for the alarms.
Then request another RX Antenna Test.
If the alarm is cleared, the procedure is completed

...................................................................................................................................................................................................................................
15-142 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Cell_receiveAntennaTestThresholdExceededOnAntenna2
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the RX path (Filter, RF cabling and RX antenna) is
working properly.
Replace RX antenna 2 if required.
...................................................................................................................................................................................................

3 At the OMC-UPS, request another RX Antenna Test.


If the alarm is cleared, the procedure is completed
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-143
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Cell_temporarySoftwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cell_temporarySoftwareFailure
alarm.

Description
A temporary software failure occured leading to disabled/failed common or shared
channels.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Software failure.

System impact
The service of the cell is impacted dependant on the failed channel. The availability of
the channels is reported via NBAP.

Automatic corrective actions


The Node B periodically attempts (every 5 minutes) to enable failed channels.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No immediate action required.

...................................................................................................................................................................................................................................
15-144 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Cell_temporarySoftwareFailure
procedures

...................................................................................................................................................................................................

2 If the alarm is not cleared automatically, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-145
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

DigitalShelfFan alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the digital shelf fan.

Contents

DigitalShelfFan_equipmentFault 15-147

...................................................................................................................................................................................................................................
15-146 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

DigitalShelfFan_equipmentFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the DigitalShelfFan_equipmentFault
alarm.

Description
The fan in the Digital Shelf failed.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Fan failure.

System impact
The system will be impacted as indicated below:
• The shelf temperature will rise causing over-temperature alarms on the boards if the
alarm is pending and the operational state of the DigitalShelfFan MO is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.
• Over temperature alarms result in shutdown of boards and dropped calls on the
Node B.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, replace the fan tray.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-147
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance DigitalShelfFan_equipmentFault
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-148 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the E1T1 port.

Contents

E1T1Port_aISDetected 15-150
E1T1Port_atmSyncLost 15-152
E1T1Port_bitErrorRateGreaterThan1PerMillion 15-154
E1T1Port_bitErrorRateGreaterThan1PerThousand 15-156
E1T1Port_configurationMismatch 15-158
E1T1Port_frameLost 15-160
E1T1Port_frameMissed 15-162
E1T1Port_frameSlip 15-164
E1T1Port_iMALinkAlarm 15-166
E1T1port_localConfigurationFailure 15-168
E1T1Port_remoteAlarmIndication 15-170
E1T1Port_signalLost 15-172
E1T1Port_unexpectedIMAGroup 15-174

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-149
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_aISDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_aISDetected alarm.

Description
At the reported DS1 port, the Node B detected an AIS signal. This alarm indicates a
problem in the equipment at the remote end of the E1/T1 connection.
For a T1 configured port, this alarm is also known as BLUE ALARM.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Loss of frame due to internal equipment fault at the remote end of the E1/T1 line. This
is most probably the ATM router interface card or an internal ATM router problem.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-150 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_aISDetected
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the equipment for the reason to send an AIS signal towards the Node B and
take the appropriate action.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-151
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_atmSyncLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_atmSyncLost alarm.

Description
At the reported DS1, loss of the ATM stream synchonisation has been detected.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Loss of signal due to link interuption or equipment malfunction

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Make sure that the E1/T1 line and both sides of the interface cards are working
properly.

...................................................................................................................................................................................................................................
15-152 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_atmSyncLost
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-153
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_bitErrorRateGreaterThan1PerMillion
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
E1T1Port_bitErrorRateGreaterThan1PerMillion alarm.

Description
At the reported DS1 port, the Node B detected a Bit Error Rate which is greater than
10E–6.
For a T1 configured port, the calculation is based on CRC-6 (Extended superframe) or
framing (superframe) errors. For an E1 configured port, the calculation is based on
framing errors.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Communication protocol error.

System impact
The E1/T1 link quality is degraded. Communication to the RNC is affected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-154 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_bitErrorRateGreaterThan1PerMillion
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check:

If... Then...
The fault is cleared after a short Go to step 2.
time and when it does not occur
frequently,
The fault is steadily active or Go to step 3
occurs frequently,

...................................................................................................................................................................................................

2 Check the DS1 port carefully in case of more frequent occurrences of this alarm and
act accordingly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 Make sure that the E1/T1 line to the router, interface card of the router and the router
are working properly.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-155
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_bitErrorRateGreaterThan1PerThousand
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
E1T1Port_bitErrorRateGreaterThan1PerThousand alarm.

Description
At the reported DS1 port, the Node B detected a Bit Error Rate which is greater than
1E-3. For a E1 configured port, the calculation is based on framing errors. For a T1
configured port, the calculation is based on CRC-6 (Extended superframe) or framing
(superframe) errors. The limit of resolution for the T1 BER detection is therefore
2.16E-4.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Communication protocol error.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-156 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_bitErrorRateGreaterThan1PerThousand
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check:

If... Then...
The fault is cleared after a short Go to step 2.
time and when it does not occurs
frequently,
The fault is steadily active or Go to step 3
occurs frequently,

...................................................................................................................................................................................................

2 Check the DS1 port carefully in case of more frequent occurrences of this alarm and
act accordingly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 Make sure that the E1/T1 line to the router, interface card of the router, and the router
are working properly.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-157
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_configurationMismatch
alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.
...................................................................................................................................................................................................................................
15-158 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-159
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_frameLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_frameLost alarm.

Description
At the reported DS1 port, the Node B detected a loss of frame synchronization of the
E1/T1 signal. For example, the Node B can not detect the framing pattern.
For a T1 configured port, this alarm is known as RED ALARM. For an E1 configured
port, the alarm is raised after three consecutive incorrect frame alignment signals.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Timing problem.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-160 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_frameLost
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Make sure that the E1/T1 line and both sides of the interface cards are working
properly.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-161
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_frameMissed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_frameMissed alarm.

Description
At the reported DS1, the NodeB detected missed/repeated frames. This alarm is
reported, when the number of missed/repeated frame incidents reached a certain
threshold.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
framing error.

System impact
The E1/T1 link quality is degraded. Communication to the RNC is affected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check ATM equipment for correct configuration..


If the alarm is cleared after 30 minutes, the procedure is completed.
...................................................................................................................................................................................................

2 Make sure that the E1/T1 line is working properly.


If the alarm is cleared after 30 minutes, the procedure is completed.
...................................................................................................................................................................................................................................
15-162 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_frameMissed
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-163
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_frameSlip
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_frameSlip alarm.

Description
At the reported DS1 port, the Node B detected a frame slip. This alarms indicates a
problem with the clock synchronization between the Node B and the transport network.
This alarm is raised if the number of slip incidents reaches a threshold.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Framing error.

System impact
The E1/T1 link quality is degraded. Communication to the RNC is affected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check ATM equipment for correct configuration


If the alarm is cleared after 30 minutes, the procedure is completed.
...................................................................................................................................................................................................

2 Make sure that the E1/T1 line is working properly


If the alarm is cleared after 30 minutes, the procedure is completed.
...................................................................................................................................................................................................................................
15-164 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_frameSlip
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-165
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_iMALinkAlarm
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_iMALinkAlarm alarm.

Description
This alarm indicates a failure for the IMA E1/T1 Link.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible route causes are:
1. Loss of IMA Frame.
2. Link out of delay syncronization
3. Remote failure indication
4. Tx link unusable
5. Rx link unusable
6. Link misconfiguration (link addition failure)
7. Tx link misconnected
8. Rx link misconnected
9. ATM Edge device removed failed link from IMA Group.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

...................................................................................................................................................................................................................................
15-166 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_iMALinkAlarm
procedures

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for other (non-IMA) E1T1Port alarms and perform fault
clearance procedure for these alarms.
If the alarm is cleared, together with the other E1T1Port alarms, the procedure is
completed.
...................................................................................................................................................................................................

2 Initiate enhanced link tests to identify and correct the root cause.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-167
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1port_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1port_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
The E1/T1 link is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.

...................................................................................................................................................................................................................................
15-168 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1port_localConfigurationFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, use the remote RMT tool to check the following configuration data:
• Trunk Group Member parameters.
• ATMPHY parameters
Configure the parameters if required.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-169
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_remoteAlarmIndication
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_remoteAlarmIndication
alarm.

Description
At the reported DS1 port, the Node B detected a remote alarm indication signal. This
alarm indicates a problem at the remote end of the E1/T1 connection.
The alarm indicates a synchronization or bit error rate problem at the ATM router
interface card or an internal ATM router problem.
For a T1 configured port, this alarm is known as YELLOW ALARM.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Synchronization/Bit error rate problem or internal problem at the remote end.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-170 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_remoteAlarmIndication
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check ATM equipment at the remote end of the E1/T1 line and take appropriate action.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 Make sure that the E1/T1 line to the router, interface card of the router, and the router
are working properly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-171
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_signalLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_signalLost alarm.

Description
At the reported DS1 port, the Node B detected no E1/T1 signal. The pulse density is
below the level where the clock signal can be derived.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Loss of signal due to link interuption or equipment malfunction

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Make sure that the E1/T1 line and both sides of the interface cards are working
properly.

...................................................................................................................................................................................................................................
15-172 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_signalLost
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-173
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E1T1Port_unexpectedIMAGroup
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E1T1Port_unexpectedIMAGroup
alarm.

Description
An unexpected IMA group has been auto-detected.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
E1/T1 link auto-detected in IMA group, but referenced by IubInterface object.

System impact
Virtual Channel Links (VCLs) associated with this E1/T1 link are not available for
service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, verify and update the IMA configuration, so that the IMA
configuration of the Node B matches the IMA configuration on the ATM Edge Device.

...................................................................................................................................................................................................................................
15-174 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E1T1Port_unexpectedIMAGroup
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-175
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the E3T3Port alarms.

Contents

E3T3Port_linkFailureAIS 15-177
E3T3Port_linkFailureHBER 15-179
E3T3Port_linkFailureLBER 15-181
E3T3Port_linkFailureLOF 15-183
E3T3Port_linkFailureLOS 15-185
E3T3Port_linkFailureOOF 15-187
E3T3Port_linkFailureRDI 15-188
E3T3port_localConfigurationFailure 15-190

...................................................................................................................................................................................................................................
15-176 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureAIS
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureAIS alarm.

Description
An Alarm Indication Signal (AIS) failure has been detected..

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Transmission problem upstream of the E3/T3 line.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, Check the remote end of the E3/T3 line for sending the AIS signal
and take the appropriate action.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-177
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureAIS
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-178 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureHBER
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureHBER alarm.

Description
The bit error rate (BER) on the E3T3 link has exceeded 10^-3.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Poor link quality on the E3/T3 line.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the E3/T3 line and take the appropriate action

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-179
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureHBER
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-180 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureLBER
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureLBER alarm.

Description
The bit error rate (BER) on the E3T3 link has exceeded 10-6.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Poor link quality on the E3/T3 line.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the E3/T3 line and take the appropriate action.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-181
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureLBER
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-182 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureLOF
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureLOF alarm.

Description
A Loss of Frame (LOF) failure has been detected.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
The E3/T3 port is not synchronized with the transmission link.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the E3/T3 line and take the appropriate action.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-183
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureLOF
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-184 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureLOS
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureLOS alarm.

Description
A loss of signal (LOS) failure has been detected.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Loss of signal due to link interuption or equipment malfunction.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the E3/T3 line and take the appropriate action.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-185
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureLOS
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-186 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureOOF
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureOOF alarm.

Description
An Out of Frame (OOF) failure has been detected.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Extensive OOF conditions.

System impact
The E3/T3 link quality may be degraded.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Ensure that the E3/T3 line and both sides of the interface cards are working correctly.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-187
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E3T3Port_linkFailureRDI
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3Port_linkFailureRDI alarm.

Description
A Remote Defect Indication (RDI) failure has been detected.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Link problem at the remote end of the line.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the E3/T3 line and take the appropriate action.

...................................................................................................................................................................................................................................
15-188 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E3T3Port_linkFailureRDI
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-189
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

E3T3port_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the E3T3port_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
The STM/OC3 link is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, use the RMT tool to check the Trunk Group Member parameters
Configure the parameters if required.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-190 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance E3T3port_localConfigurationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-191
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

EthernetPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the ethernetPort alarms.

Contents

EthernetPort_portFailure 15-193

...................................................................................................................................................................................................................................
15-192 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

EthernetPort_portFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the EthernetPort_portFailure alarm.

Description
The Ethernet Port has failed and is unavailable for service.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Equipment failure.

System impact
Ethernet cut through failed.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the NodeB, replace the LIU card.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-193
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

ExtRxAmp alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Tower Top Low Noise
Amplifier (TTLNA).

Contents

ExtRxAmp_configurationMismatch 15-195
ExtRxAmp_equipmentFault 15-197
ExtRxAmp_localConfigurationFailure 15-199

...................................................................................................................................................................................................................................
15-194 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ExtRxAmp_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtRxAmp_configurationMismatch
alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-195
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ExtRxAmp_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-196 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ExtRxAmp_equipmentFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtRxAmp_equipmentFault alarm.

Description
One TTLNA associated with a filter panel failed. It will automatically be bypassed. As
a result the radio functionality will be impaired, but still be present.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Filter panel failure
• Current limits are not defined in EEPROM of filter panel
• Power consumption of the TTLNA is out of the defined current limits.

System impact
Call capacity on this cell will decrease and calls on the border of the cell may be
dropped.

Automatic corrective actions


The TTLNA is switched off and is bypassed automatically.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for filter alarms and perform the fault clearance procedures
for those alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-197
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ExtRxAmp_equipmentFault
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, lock and unlock the ExtRxAmp to reactivate the TTLNA.
...................................................................................................................................................................................................

3 At the NodeB, check whether the TTLNA descriptor of the associated filter panel is
OK and configure the TTLNA descriptor if required.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the NodeB, check the TTLNA LED of the associated filter panel:

If ... then ...


the LED is green and the alarm is the procedure is completed.
cleared,
the LED is red, replace the TTLNA.
If the alarm is cleared, the procedure is
completed.

...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-198 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

ExtRxAmp_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtRxAmp_localConfiguration-
Failure alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-199
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance ExtRxAmp_localConfigurationFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-200 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Filter alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the filter shelf.

Contents

Filter_communicationFailure 15-202
Filter_configurationMismatch 15-204
Filter_dCConverterFailure 15-206
Filter_hardwareModelMismatch 15-208
Filter_localConfigurationFailure 15-210
Filter_unknownHardwareModel 15-212

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-201
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_communicationFailure alarm.

Description
The heartbeat synchronization between the Filter unit and the Universal Radio
Controller (URC) has been lost or timeout occured during initialisation of the TxAmp.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.

System impact
The system will be impacted as indicated below:
• ExtRxAmp supported by the power supply within the filter might report errors
• Affected cells are degraded if the alarm is pending and the operational state of the
Filter MO is disabled.
• If this was the only Filter unit or the last Filter unit which served the cell, the cell
is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-202 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_communicationFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the Filter unit is mounted correctly in the shelf.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the cabling is OK.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

4 At the Node B, replace the Filter unit.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-203
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
15-204 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-205
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_dCConverterFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_dCConverterFailure alarm.

Description
The DC converter within the Filter unit has detected a failure.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment malfunction. This can be caused by a hardware problem or disruption of the
power supply to the Filter unit.

System impact
The system will be impacted as indicated below:
• ExtRxAmp supported by the power supply within the Filter unit might report errors
• Affected cells are degraded if the alarm is pending and the operational state of the
Filter MO is disabled.
• If this was the only Filter unit or the last Filter unit which served the cell, the cell
is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-206 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_dCConverterFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the Filter unit is powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the circuit breaker switch and cabling to the Filter unit
are OK
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

4 At the Node B, replace the Filter unit.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-207
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_hardwareModelMismatch
alarm.

Description
The detected Filter hardware model does not match the value specified.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedFilterHardwareModel Go to step 2.
is incorrect,

...................................................................................................................................................................................................................................
15-208 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_hardwareModelMismatch
procedures

If ... then ...


an install of the correct hardware model is Go to step 6.
required,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object associated with the Filter.
...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

6 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

7 At the Node B, replace the Filter unit.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-209
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.

...................................................................................................................................................................................................................................
15-210 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_localConfigurationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support to check the local
configuration data of the Filter and provide the additionalText of the alarm.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-211
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Filter_unknownHardwareModel
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Filter_unknownHardwareModel
alarm.

Description
The detected Filter hardware model is not known by the software.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Invalid or new filter unit not supported by the NodeB

System impact
Correct operation of the corresponding cell cannot be guaranteed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Contact Alcatel-Lucent customer support to verify the function code (attribute


vendorUnitFamilyType) of the Filter unit.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object associated with the Filter.
...................................................................................................................................................................................................

3 At the NodeB, replace the Filter unit

...................................................................................................................................................................................................................................
15-212 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Filter_unknownHardwareModel
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-213
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Frame alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Node B frame.

Contents

Frame_cabinetDoorOpen 15-215
Frame_cabinetHeaterFailure 15-217
Frame_fanFault 15-219
Frame_heatManagementSystemCompressorFailure 15-221
Frame_heatManagementSystemControllerFailure 15-223
Frame_overTemperature 15-225
Frame_underTemperature 15-227

...................................................................................................................................................................................................................................
15-214 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_cabinetDoorOpen
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_cabinetDoorOpen alarm.

Description
This alarm is raised, when the cabinet door is opened.

Default severity
Major

Alarm type
physicalViolation

Root cause
If the alarm has not been triggered by service personnel working at the enclosure door,
there are two possible reasons for the alarm:
• The cabinet door has been opened by an unknown person
• The door contacts may be faulty.

System impact
None.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Perform the safety actions defined by the network operator.


...................................................................................................................................................................................................

2 At the Node B, make sure that the cabinet shows no marks of vandalism or a faulty
door contact.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-215
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_cabinetDoorOpen
procedures

Repair damaged door contacts and any other damages that are visible.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-216 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_cabinetHeaterFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_cabinetHeaterFailure alarm.

Description
The BTS cabinet heater has failed. This alarm occurs only on Macrocell Compact
Outdoor versions (V1) which have an intelligent heater controller and on Modular Cell
Outdoor.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
The cabinet heater has failed.

System impact
No immediate impact.
The temperature in the frame can drop and cause temperature alarms on the boards in
the frame. Temperature alarms result in shutdown of boards and can cause dropped
calls on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, repair or replace the cabinet heater.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-217
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_cabinetHeaterFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-218 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_fanFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_fanFault alarm.

Description
A fan in the BTS frame is not functioning properly.This alarm occurs only on Modular
Cell Outdoor.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Heating, ventilation or cooling system problem.

System impact
No immediate impact.
The temperature in the frame can rise and cause over-temperature alarms on the boards
in the frame. Over- temperature alarms result in shutdown of boards and can cause
dropped calls on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, replace the fan.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-219
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_fanFault
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-220 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_heatManagementSystemCompressorFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_heatManagementSystemCom-
pressorFailure alarm.

Description
The BTS frame Heat Management System compressor has failed. This alarm occurs
only on Modular Cell Outdoor.

Severity
Critical

Root cause
Heating or ventilation or cooling system problem.

System impact
No immediate impact.
The temperature in the system can exceed thresholds and cause temperature alarms on
the boards in the system. Temperature alarms result in shutdown of boards and can
cause dropped calls on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, repair of replace the Frame Heat Management System Compressor.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-221
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_heatManagementSystemCompressorFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-222 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_heatManagementSystemControllerFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_heatManagementSystemCon-
trollerFailure alarm.

Description
The BTS frame Heat Management System controller has failed. This alarm occurs only
on Macrocell Compact Outdoor versions (V1) which have an intelligent heater
controller and on Modular Cell Outdoor.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Heating or ventilation or cooling system problem.

System impact
No immediate impact.
The temperature in the system can exceed thresholds and cause temperature alarms on
the boards in the system. Temperature alarms result in shutdown of boards and can
cause dropped calls on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-223
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_heatManagementSystemControllerFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, repair or replace the Frame Heat Management System Controller.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-224 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_overTemperature alarm.

Description
The BTS frame Heat Management System is indicating that the temperature is above a
preset threshold. This alarm occurs only on Macrocell Compact Outdoor versions (V1)
which have an intelligent heater controller and on Modular Cell Outdoor.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
Unacceptable high temperature.

System impact
No immediate impact.
The over-temperature in the frame can cause over-temperature alarms on the boards in
the frame. Over temperature alarms result in shutdown of boards and can cause
dropped calls on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that there are no other temperature related alarms.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-225
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_overTemperature
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the Node B, repair the heat management system.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-226 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Frame_underTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Frame_underTemperature alarm.

Description
The BTS frame Heat Management System is indicating that the temperature is below a
preset threshold. This alarm occurs only on Macrocell Compact Outdoor versions (V1)
which have an intelligent heater controller and on Modular Cell Outdoor.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
Unacceptable low temperature.

System impact
No immediate impact.
The under-temperature in the frame can cause temperature alarms on the boards in the
frame. Temperature alarms result in shutdown of boards and can cause dropped calls
on the Node B.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 3 hours.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that there are no other temperature related alarms.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-227
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Frame_underTemperature
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the Node B, repair the heat management system.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-228 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

GRS alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the GRS alarms.

Contents

GRS_configurationMismatch 15-230
GRS_firstPortNumberAlreadyInUse 15-232
GRS_gPSAntennaFailure 15-234
GRS_gPSAntennaPositionUnknown 15-236
GRS_gPSReceiverFailure 15-238
GRS_gPSReceiverUnavailable 15-240
GRS_satelliteHealthyThresholdExceededForAllVisibleSatellites 15-241
GRS_secondPortNumberAlreadyInUse 15-243
GRS_selfSurveyFailed 15-245

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-229
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_configurationMismatch.

Description
No appropriate CTU found or configured.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
This Node B will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that a CTU object exists.


If not, run the add NodeB use case.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the syncSource attribute of the NodeB object is not
equal to ″network″, ″internalGPS″ or ″externalGPS″

...................................................................................................................................................................................................................................
15-230 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance GRS_configurationMismatch
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, check for syncSourceMismatch alarm of the CTU and perform the
fault clearance procedure of that alarm.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, check for hardwareModelMismatch alarm of the CTU and perform
the fault clearance procedure of that alarm.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-231
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_firstPortNumberAlreadyInUse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_firstPortNumberAlreadyInUse
alarm.

Description
The GRS could not open a TCP/IP port with the specified port number because there is
already another port opened with the same port number.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The operator selected a port number which was already assigned previously to another
service.

System impact
This NodeB will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the GRS object, update firstPortNumber attribute to assign
another port number and unlock the GRS object.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-232 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance GRS_firstPortNumberAlreadyInUse
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-233
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_gPSAntennaFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_gPSAntennaFailure alarm.

Description
The Global Positioning System (GPS) receiver detected that the GPS antenna or the
antenna cable is broken.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
This Node B will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the GPS antenna and the GPS antenna cable are intact
and working properly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.

...................................................................................................................................................................................................................................
15-234 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance GRS_gPSAntennaFailure
procedures

...................................................................................................................................................................................................

3 At the Node B, replace the CTU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-235
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_gPSAntennaPositionUnknown
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_gPSAntennaPositionUnknown
alarm.

Description
The position of the GPS Antenna is not available to the NodeB.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Possible root causes are:
• Position not written into backplane
• Self survey not yet performed

System impact
This NodeB will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, invoke the self-survey action at the GRS object.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-236 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance GRS_gPSAntennaPositionUnknown
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-237
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_gPSReceiverFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_gPSReceiverFailure alarm.

Description
The Common Timing Unit (CTU) detected a Global Positioning System (GPS) receiver
failure.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
This Node B will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the GPS antenna, the GPS antenna cable, receiver, and
the clock splitter are working properly.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

3 At the Node B, replace the CTU.

...................................................................................................................................................................................................................................
15-238 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance GRS_gPSReceiverFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-239
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

GRS_gPSReceiverUnavailable
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_gPSReceiverUnavailable.

Description
The GPS receiver is not available.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Underlying resource unavailable.

System impact
This Node B will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for CTU alarms and perform the fault clearance procedure for
these alarms.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-240 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

GRS_satelliteHealthyThresholdExceededForAllVisibleSatellites
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_satelliteHealthyThreshold-
ExceededForAllVisibleSatellites alarm.

Description
The NodeB detects that for all visible satellites the averaged pseudorange correction
value exceeds the Satellite Healthy Threshold.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The coordinates of the GPS antenna are not correct.

System impact
This NodeB will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the coordinates of the GPS antenna. Consider initiating a self
survey so that the GPS antenna location can be determined autonomously by the
system.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-241
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures GRS_satelliteHealthyThresholdExceededForAllVisibleSatellites

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-242 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

GRS_secondPortNumberAlreadyInUse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_secondPortNumberAlreadyI-
nUse alarm.

Description
The GRS could not open a TCP/IP port with the specified port number because there is
already another port opened with the same port number.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The operator selected a port number which was already assigned previously to another
service.

System impact
This NodeB will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the GRS object, update secondPortNumber attribute to assign
another port number and unlock the GRS object.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-243
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance GRS_secondPortNumberAlreadyInUse
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-244 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

GRS_selfSurveyFailed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GRS_selfSurveyFailed.

Description
The Self Survey could not be completed successfully.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Underlying resource unavailable.

System impact
This Node B will not provide GRS service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for gPSReceiverFailure and gPSAntennaFailure alarms of


GRS and perform fault clearance procedure of these alarms.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for CTU alarms and perform fault clearance procedure of
these alarms.
...................................................................................................................................................................................................

3 At the OMC-UPS, invoke the self-survey action at the GRS object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-245
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance GRS_selfSurveyFailed
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-246 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

IMAGroup alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the IMA Group alarms.

Contents

IMAGroup_criticalGroupAlarm 15-248
IMAGroup_criticalGroupConfigurationAlarm 15-250
IMAGroup_majorGroupAlarm 15-252
IMAGroup_noncriticalGroupConfigurationAlarm 15-254

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-247
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IMAGroup_criticalGroupAlarm
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IMAGroup_criticalGroupAlarm
alarm.

Description
This alarm indicates a critical problem for the IMA Group. The IMA Group is no
longer operational.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible root causes are:
1. All transmit and/or all receive links are down.
2. ATM Edge Device indicates that less than minimum number of transmit or receive
links are active.
3. ATM Edge Device indicates the group is starting up.
4. ATM Edge Device indicates it is blocked.
5. This IMAGroup is not configured on ATM Edge Device.

System impact
IMA Group not available for traffic if the alarm is pending and the operational state of
the IMAGroup MO is disabled.
In case of a intermittent fault condition, the alarm is only cleared if the fault didn’t
occur again within 20 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-248 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IMAGroup_criticalGroupAlarm
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for E1T1Port alarms and perform fault clearance procedures
for these alarms.
If the alarm is cleared, together with the E1T1Port alarms, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for noncriticalGroupConfiguration alarm and perform the


fault clearance procedure for that alarm.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-249
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IMAGroup_criticalGroupConfigurationAlarm
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IMAGroup_criticalGroupConfigu-
rationAlarm alarm.

Description
This Alarm indicates a critical configuration problem for the IMA Group detected on
Node B.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Configuration failure:
1. The ATM Edge Device tries to use unacceptable configuration parameters.
2. The ATM Edge Device reports unacceptable configuration parameters.

System impact
IMA Group not available for traffic.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, verify the IMA Group parameters and correct the configuration.

...................................................................................................................................................................................................................................
15-250 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IMAGroup_criticalGroupConfigurationAlarm
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-251
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IMAGroup_majorGroupAlarm
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IMAGroup_majorGroupAlarm alarm.

Description
This alarm indicates a major problem for the IMA Group. The IMA group is still
operational

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible root causes:
• One or more IMA links have failed.
• Number of auto-detected enabled IMA links less than number of configured IMA
links.

System impact
Bandwidth of IMA Group is degraded if the alarm is pending and the operational state
/ AVS of the IMAGroup MO is enabled / degraded.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 20 minutes.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-252 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IMAGroup_majorGroupAlarm
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for criticalGroupAlarm and perform the fault clearance
procedure for that alarm.
If the alarm is cleared, together with the criticalGroupAlarm, the procedure is
completed
...................................................................................................................................................................................................

2 At the OMC-UPS, check for E1T1Port alarms and perform fault clearance procedure
for these alarms.
If the alarm is cleared, together with the E1T1Port alarms, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, check for noncriticalGroupConfigurationAlarm and perform fault


clearance procedure for that alarm
If the alarm is cleared, together with the noncriticalGroupConfigurationAlarm, the
procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-253
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IMAGroup_noncriticalGroupConfigurationAlarm
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IMAGroup_noncriticalGroupCon-
figurationAlarm alarm.

Description
This Alarm indicates a noncritical configuration problem for the IMA Group detected
on NodeB.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Possible root causes:
1. Configuration mismatch between the ATM Edge Device and the NodeB: configured
IMA links do not match auto-detected ones.
2. Different timeslot allocation detected for E1T1Ports of the same IMAGroup.
3. At least one traffic PVC configured via IubInterface object has been blocked or its
bandwidth has been reduced, since the configured bandwidth of the IMAGroup
cannot carry all PVCs of the IubInterface object.

System impact
Traffic on IMA Group may be degraded.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-254 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IMAGroup_noncriticalGroupConfigurationAlarm
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, verify the IMA Group parameters: compare iMAE1T1LinksFarEnd


attribute containing auto-detected links with iMAE1T1Link attribute containing the
configured links. Compare the iMAGroupIdent attribute of the IMAGroup with the
iMAGroupReference of the E1T1Port objects referenced by the IMAGroup object.
Update the IMA configuration on the ATM Edge Device or on the NodeB, if required.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, verify whether the bandwidth of the IMAGroup is sufficient to


carry all PVCs of the IubInterface object assigned to this IMAGroup. Update the
configuration of the IubInterface object if required.
...................................................................................................................................................................................................

3 At the OMC-UPS, check the trunkGroupMember attribute of all E1T1Port objects


referenced by the IMAGroup. If the attributes are not identical, update the wrong trunk
group member data via remote RMT.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-255
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Input Output Unit (IOU).

Contents

IOU_communicationFailure 15-258
IOU_externalAlarmPort0 15-260
IOU_externalAlarmPort1 15-262
IOU_externalAlarmPort10 15-264
IOU_externalAlarmPort11 15-266
IOU_externalAlarmPort12 15-268
IOU_externalAlarmPort13 15-270
IOU_externalAlarmPort14 15-272
IOU_externalAlarmPort15 15-274
IOU_externalAlarmPort16 15-276
IOU_externalAlarmPort17 15-278
IOU_externalAlarmPort18 15-280
IOU_externalAlarmPort19 15-282
IOU_externalAlarmPort2 15-284
IOU_externalAlarmPort20 15-286
IOU_externalAlarmPort21 15-288
IOU_externalAlarmPort22 15-290
IOU_externalAlarmPort23 15-292
IOU_externalAlarmPort24 15-294
IOU_externalAlarmPort25 15-296
IOU_externalAlarmPort26 15-298
IOU_externalAlarmPort27 15-300
IOU_externalAlarmPort28 15-302
IOU_externalAlarmPort29 15-304

...................................................................................................................................................................................................................................
15-256 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

IOU_externalAlarmPort3 15-306
IOU_externalAlarmPort30 15-308
IOU_externalAlarmPort31 15-310
IOU_externalAlarmPort4 15-312
IOU_externalAlarmPort5 15-314
IOU_externalAlarmPort6 15-316
IOU_externalAlarmPort7 15-318
IOU_externalAlarmPort8 15-320
IOU_externalAlarmPort9 15-322

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-257
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_communicationFailure alarm.

Description
Heartbeat synchronization between the Input Output Unit (IOU) and the Universal
Radio Controller (URC) has been lost.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
The system will be impacted as indicated below:
• Communication to the RNC and OMC-U might be affected in case of E1/T1.
• User alarms are no longer signaled if the alarm is pending and the operational state
of the IOU MO is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault didn’t
occur again within 3 hours.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the IOU is mounted properly in the shelf.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-258 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_communicationFailure
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the cabling is correct.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, replace the IOU.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-259
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort0
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort0 alarm.

Description
An alarm on external alarm port 0 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 0.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined specific
Problem.
...................................................................................................................................................................................................................................
15-260 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort0
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-261
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort1
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort1 alarm.

Description
An alarm on external alarm port 1 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 1.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-262 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort1
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-263
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort10
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort10 alarm.

Description
An alarm on external alarm port 10 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 10.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-264 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort10
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-265
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort11
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort11 alarm.

Description
An alarm on external alarm port 11 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 11.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-266 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort11
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-267
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort12
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort12 alarm.

Description
An alarm on external alarm port 12 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 12.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-268 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort12
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-269
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort13
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort13 alarm.

Description
An alarm on external alarm port 13 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 13.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-270 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort13
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-271
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort14
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort14 alarm.

Description
An alarm on external alarm port 14 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 14.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-272 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort14
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-273
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort15
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort15 alarm.

Description
An alarm on external alarm port 15 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 15.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-274 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort15
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-275
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort16
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort16 alarm.

Description
An alarm on external alarm port 16 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 16.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-276 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort16
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-277
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort17
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort17 alarm.

Description
An alarm on external alarm port 17 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 17.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-278 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort17
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-279
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort18
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort18 alarm.

Description
An alarm on external alarm port 18 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 18.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-280 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort18
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-281
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort19
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort19 alarm.

Description
An alarm on external alarm port 19 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 19.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-282 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort19
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-283
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort2 alarm.

Description
An alarm on external alarm port 2 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 2.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-284 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort2
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-285
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort20
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort20 alarm.

Description
An alarm on external alarm port 20 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 20.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-286 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort20
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-287
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort21 alarm.

Description
An alarm on external alarm port 21 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 21.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-288 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort21
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-289
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort22
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort22 alarm.

Description
An alarm on external alarm port 22 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 22.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-290 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort22
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-291
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort23
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort23 alarm.

Description
An alarm on external alarm port 23 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 23.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-292 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort23
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-293
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort24
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort24 alarm.

Description
An alarm on external alarm port 24 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 24.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-294 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort24
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-295
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort25
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort25 alarm.

Description
An alarm on external alarm port 25 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 25.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-296 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort25
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-297
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort26
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort26 alarm.

Description
An alarm on external alarm port 26 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 26.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-298 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort26
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-299
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort27
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort27 alarm.

Description
An alarm on external alarm port 27 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 27.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-300 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort27
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-301
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort28
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort28 alarm.

Description
An alarm on external alarm port 28 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 28.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-302 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort28
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-303
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort29
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort29 alarm.

Description
An alarm on external alarm port 29 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 29.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-304 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort29
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-305
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort3
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort3 alarm.

Description
An alarm on external alarm port 3 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 3.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-306 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort3
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-307
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort30
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort30 alarm.

Description
An alarm on external alarm port 30 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 30.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-308 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort30
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-309
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort31
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort31 alarm.

Description
An alarm on external alarm port 31 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 31.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-310 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort31
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-311
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort4
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort4 alarm.

Description
An alarm on external alarm port 4 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 4.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-312 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort4
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-313
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort5
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort5 alarm.

Description
An alarm on external alarm port 5 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 5.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-314 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort5
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-315
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort6
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort6 alarm.

Description
An alarm on external alarm port 6 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 6.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-316 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort6
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-317
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort7
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort7 alarm.

Description
An alarm on external alarm port 7 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 7.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-318 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort7
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-319
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort8
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort8 alarm.

Description
An alarm on external alarm port 8 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 8.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-320 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort8
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-321
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

IOU_externalAlarmPort9
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IOU_externalAlarmPort9 alarm.

Description
An alarm on external alarm port 9 has been detected. The description depends on the
site-specific configuration and is contained in the alarm text.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
The probable cause depends on the site-specific configuration.

System impact
This depends on the nature of the external equipment connected to the external alarm
port 9.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Extract the user-defined specificProblem and user-defined additionalText from the


additional text of the alarm. The Node B has set this information according to the
IOU::externalAlarms attribute.
...................................................................................................................................................................................................

2 Request a service technician to take action depending upon the user-defined


specificProblem.
...................................................................................................................................................................................................................................
15-322 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance IOU_externalAlarmPort9
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-323
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Iub interface alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Iub interface.

Contents

IubInterface_rNCCommunicationLost 15-325

...................................................................................................................................................................................................................................
15-324 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

IubInterface_rNCCommunicationLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IubInterface_rNCCommunicationLost
alarm.

Description
The ALCAP and/or NBAP connection to the RNC has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• Hardware problems
• Link failure
• Communication software failure on the Node B or the RNC

System impact
Loss of service for the whole Node B if the alarm is pending and the operational state
of the IubInterface MO is disabled. The operational state is set to disabled if ALCAP
and/or NBAP connection is down.
In case of a intermittent fault condition, the alarm is only cleared if the fault didn’t
occur again within 20 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-325
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance IubInterface_rNCCommunicationLost
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for RNC alarms indicating IubInterface problems and perform
fault clearance procedure for these alarms
If the alarm is cleared, together with the RNC alarms, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for E1T1Port, IMAGroup, E3T3Port and STM1OC3Port


alarms and perform fault clearance procedure for these alarms.
If the alarm is cleared, together with the other E1T1Port alarms, the procedure is
completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, verify and if necessary correct the ATM settings for the ALCAP and
NBAP connection.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-326 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the NodeB object alarms.

Contents

NodeB_alarmDefFileCorrupt 15-328
NodeB_alarmDefFileMissing 15-330
NodeB_databaseCleared 15-332
NodeB_databaseRestoredFromSnapshot 15-335
NodeB_filesystemNearingCapacity 15-337
NodeB_filesystemObjectCorrupt 15-339
NodeB_invalidSecurityDataDetected 15-341
NodeB_ipfwNatRulesAltered 15-343
NodeB_nodeBTypeMismatch 15-345
NodeB_snapshotFailed 15-347
NodeB_unauthorizedLoginAttempt 15-349
NodeB_userPasswordLoginAttempt 15-351

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-327
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

NodeB_alarmDefFileCorrupt
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_alarmDefFileCorrupt alarm.

Description
The Alarm Definition File (ADF) is corrupted and could not be parsed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
ADF corrupted due to hardware problem or manual intervention

System impact
No impact on service

Automatic corrective actions


NodeB uses default alarm definitions for alarm reporting. NodeB does not remove
corrupt ADF.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, perform the update alarm definition use case to download and
install a default or modified ADF on the NodeB.

...................................................................................................................................................................................................................................
15-328 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance NodeB_alarmDefFileCorrupt
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-329
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

NodeB_alarmDefFileMissing
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_alarmDefFileMissing alarm.

Description
The Alarm Definition File (ADF) could not be found.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Probable root causes are:
• ADF lost due to software problem
• Hardware problem
• Manual intervention

System impact
No impact on service

Automatic corrective actions


NodeB autonomously installs default ADF, which is part of the NodeB software
currently running on the NodeB.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, perform the update alarm definition use case to download and
install a default or modified ADF on the NodeB.

...................................................................................................................................................................................................................................
15-330 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance NodeB_alarmDefFileMissing
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-331
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

NodeB_databaseCleared
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_databaseCleared alarm.

Description
The Node B started up with an empty (initial) database, because:
• The Node B detected an inconsistent database and could not recover from the
snapshot file
• The Node B performed cyclic reboots.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes of the inconsistent database are:
• Hardware failure of the flash filesystem, which causes a corrupt filesystem
• Software failure
In case of cyclic reboots, the Node B clears the database as a local foult defense to
prevent the Node B performing cyclic reboots.

System impact
The Node B performs a reset and starts with an empty database. Therefore no call
processing is possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-332 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance NodeB_databaseCleared
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, select database to be restored:


a. select backup file stored at the OMC-UPS for the Node B and continue with step 2,
if the backup file is up-to-date.
b. Otherwise select suspect database snapshotted automatically by the Node B to the
FTP server (OMC-UPS) and continue with step 3.
...................................................................................................................................................................................................

2 At the OMC-UPS, run the restore NodeB database command to restore the selected
backup database file on the Node B.
If the Node B data have been restored successfully, the procedure is completed.
Otherwise continue with step 10.
...................................................................................................................................................................................................

3 At the OMC-UPS, copy the suspect database file to the backup directory of the Node
B on the OMC-UPS.
Source directory is /data/snapshot/<nodeb_local_identifier>
Target directory is /backup/backups/NodeB/<nodeb_local_identifier>
The <nodeb_local_identifier> is the ″Local identifier″, which is stored under the NE
Management Parameters of the Node B.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the Node B object, if it is not already locked.


...................................................................................................................................................................................................

5 At the OMC-UPS, run the restore NodeB database command to restore the suspect
database file on the Node B.
If the Node B data have been restored successfully, the procedure is completed.
...................................................................................................................................................................................................

6 Contact Alcatel-Lucent customer support to get the suspect database file repaired.
...................................................................................................................................................................................................

7 At the OMC-UPS, store the repaired database file on the OMC-UPS under the backup
directory of the Node B.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the Node B object, if it is not already locked.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-333
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_databaseCleared
procedures

...................................................................................................................................................................................................

9 At the OMC-UPS, run the restore Node B database command to restore the repaired
database file on the Node B.
If the Node B data has been restored successfully, the procedure is completed.
...................................................................................................................................................................................................

10 At the OMC-UPS, lock the URC object.


...................................................................................................................................................................................................

11 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

12 At the OMC-UPS, unlock the URC object.


...................................................................................................................................................................................................

13 At the OMC-UPS, repeat step 1 to restore the NodeB data.


...................................................................................................................................................................................................

14 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-334 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_databaseRestoredFromSnapshot
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_databaseRestoredFrom-
Snapshot alarm.

Description
The Node B has restored the database from the snapshot that was stored at the FTP
server (OMC-U). The database is restored as a recovery action after the Node B has
detected an inconsistent database during startup.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
This alarm indicates the database restore recovery action is performed after an
inconsistent database was detected by the Node.
Probable causes of the inconsistent database are:
• Hardware failure of the flash filesystem, which causes a corrupt filesystem
• Software failure during activation of new Node B software
• Software failure or corrupt database during restore of Node B database backup
• Software failure because of Node B reset during a Node B database update.

System impact
During the reset no call processing is possible. When the reset completes, call
processing is possible again.

Automatic corrective actions


The Node B performs a reset and restores the database from the snapshot at the FTP
server (OMC-U).

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-335
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_databaseRestoredFromSnapshot
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 If ... then ..
the alarm is raised as part of a the new software could not recover from the
node B software activation, database.
Contact Alcatel-Lucent customer support.
the alarm is raised as part of a the software could not restart with that database
restore of a database backup, and restored the database from the snapshot.
Contact Alcatel-Lucent customer support.
the alarm is raised as part of the latest Itf-B commands are not included in the
updating the database via Itf-B, restored snapshot.
Repeat the Itf-B commands.
the alarm is raised for other there may be a hardware failure of the flash
reasons, filesystem.
Contact Alcatel-Lucent customer support to check
the URC.

...................................................................................................................................................................................................

2 Check that the NodeB data has been restored successfully.


...................................................................................................................................................................................................

3 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-336 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_filesystemNearingCapacity
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_filesystemNearingCapacity
alarm.

Description
The filesystem on the persistent file storage is near capacity.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Unnecessary files are stored on the filesystem. Probably more than two NodeB
software versions are stored on the filesystem

System impact
No immediate service impact, but if the space continues to fill up, there will be
adverse effects, possibly leading to loss of data and NodeB reset. Snapshots of the
local database onto the FTP server are not performed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, avoid any configuration update for the NodeB, since the space
would continue to fill up.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-337
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_filesystemNearingCapacity
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, use the remote RMT tool to check the filesystem of the NodeB.
Remove NodeB SW versions, which are not required.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-338 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_filesystemObjectCorrupt
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_filesystemObjectCorrupt
alarm.

Description
A corrupt filesystem object has been detected.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Partially corrupted filesystem

System impact
None.

Automatic corrective actions


Corrupt filesystem objects are isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for databaseCleared and databaseRestoredFromSnapshot


alarms and perform fault clearance procedures for these alarms.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the URC object.


...................................................................................................................................................................................................

3 At the NodeB, replace the URC.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-339
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_filesystemObjectCorrupt
procedures

For a detailed replacement procedure, refer to the UMTS Node B Operation,


Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the URC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-340 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_invalidSecurityDataDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_invalidSecurityDataDetected
alarm.

Description
Invalid security data for the nodeB has been detected.
This indicates that an unknown security data exists which controls access to the
NodeB.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
securityServiceOrMechanismViolation

Root cause
Unspecified

System impact
An unknown security data compromises NodeB security.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, investigate the invalid security data, determining how and why it
was caused.
Inform the security organisation and take appropriate action to correct the security data.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-341
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_invalidSecurityDataDetected
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-342 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_ipfwNatRulesAltered
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_ipfwNatRulesAltered alarm.

Description
Internet Protocol Firewall (IPFW) or Network Address Table rules have been altered.
This determines the fundamental port security and authorization on the NodeB.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
integrityViolation

Root cause
The IPFW or NAT rules have been altered.

System impact
These rules determine port security and authorization on the NodeB, an unauthorized
change to these may indicate compromised security.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, investigate how and why the alteration took place.
If the alterations were not authorized then the operator should inform their security
organisation, then take appropriate action to correct the rules.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-343
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_ipfwNatRulesAltered
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-344 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_nodeBTypeMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_nodeBTypeMismatch alarm.

Description
The attribute detectedNodeBType retrieved from the backplane eeprom does not match
the value of the attribute expectedNodeBType.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
There may be an inconsistency between created managed objects and installed
hardware that may lead to unavailability of affected resources.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the value of attribute detectedNodeBType.

If ... then ...


the value of attribute detectedNodeBType Go to step 2.
is unknownNodeBType

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-345
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_nodeBTypeMismatch
procedures

If ... then ...


the attribute detectedNodeBTypeis any Go to step 3.
other value,

...................................................................................................................................................................................................

2 At the OMC-UPS, use the Remote Maintenance Terminal (RMT) to set the correct
Node B type in the backplane eeprom.
...................................................................................................................................................................................................

3 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-346 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_snapshotFailed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_snapshotFailed alarm.

Description
The snapshot of Node B data to the FTP server has failed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
This may alarm be reported as part of a Node B backup or as part of an autonomous
snapshot completed in case of data changes.
Probable causes are:
• FTP server down
• Link to FTP server interrupted
• FTP server misconfigured
• FTP server directory full.
• Collection and/or bundling of database has failed

System impact
No immediate effect on service, but system integrity endangered in case of loss of data
or corrupted data at the Node B.
The Node B will periodically retry to generate the snapshot. Once the snapshot is
generated the alarm will be cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-347
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_snapshotFailed
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, retrieve the detailed information from the additionalText field of the
alarm.
If the bundling and/or collection of the database has failed, contact Alcatel-Lucent
customer support.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the availability of the FTP server.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, check link to the FTP server.


...................................................................................................................................................................................................

4 At the OMC-UPS, check the FTP server configuration.


...................................................................................................................................................................................................

5 At the OMC-UPS, check space on the FTP server directory.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-348 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_unauthorizedLoginAttempt
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_unauthorizedLoginAttempt
alarm.

Description
The NodeB has detected an authentication failure.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
securityServiceOrMechanismViolation

Root cause
Failed SSH login attempt using user and key authentication.

System impact
None.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check whether the OMC-UPS application performed the failed login
attempt.
If so, ensure that the OMC-U is using the correct keys.
...................................................................................................................................................................................................

2 At the OMC-UPS, collect the security event logfile from the NodeB if required.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-349
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_unauthorizedLoginAttempt
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, perform the security actions defined by the security organization.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-350 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

NodeB_userPasswordLoginAttempt
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the NodeB_userPasswordLoginAttempt
alarm.

Description
A username/password manual authentication attempt has been made.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
securityServiceOrMechanismViolation

Root cause
Successful or failed SSH login attempt using user and password authentication.

System impact
None.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check whether the login attempt is authorized.


...................................................................................................................................................................................................

2 At the OMC-UPS, check additionalText field of the alarm to establish if the login
attempt was successful or not.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-351
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance NodeB_userPasswordLoginAttempt
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, collect the security event logfile from the NodeB if required.
...................................................................................................................................................................................................

4 At the OMC-UPS, perform the security actions defined by the security organization.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-352 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OCM alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the OCM alarms.

Contents

OCM_boardGenericMismatch 15-354
OCM_clockFailure30_72MHz 15-356
OCM_communicationFailure 15-357
OCM_initialisationFailure 15-359
OCM_lossOfForwardBusLink 15-360
OCM_lossOfPulse 15-361
OCM_missingconfigurationData 15-362
OCM_selfTestFailure 15-364

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-353
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OCM_boardGenericMismatch
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_boardGenericMismatch alarm.

Description
The software on the OCM could not be updated to the current version stored on the
URC, because the download failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-354 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OCM_boardGenericMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-355
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OCM_clockFailure30_72MHz
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_clockFailure30_72MHz alarm.

Description
The 30.72 MHz clock signal from the CTU has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


The OCM unit is reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-356 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OCM_communicationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_communicationFailure alarm.

Description
Heartbeat synchronisation between the OCM and the URC has been lost or timeout
occured during initialisation of the OCM.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-357
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance OCM_communicationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-358 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OCM_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_initialisationFailure alarm.

Description
The OneBTS CPRI module has failed to initialize correctly.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, determine the reason for failure and resolve the problem.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-359
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OCM_lossOfForwardBusLink
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_lossOfForwardBusLink alarm.

Description
Loss of forward bus link from all UCUs.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-360 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OCM_lossOfPulse
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_lossOfPulse alarm.

Description
The OCM failed to detect the 10ms pulses.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-361
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OCM_missingconfigurationData
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_missingconfigurationData
alarm.

Description
Missing essential configuration parameters on OCM

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Software failure: missing configuration data

System impact
The OCM cannot be initiated to service. No calls are possible in the related cells.

Automatic corrective actions


Isolate the OCM.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the OCM object.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the OCM object to initialize the OCM board.
...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the OCM object.


...................................................................................................................................................................................................................................
15-362 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OCM_missingconfigurationData
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-363
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OCM_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the OCM_selfTestFailure alarm.

Description
Diagnostics on the OCM have failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


TBA

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, determine the reason for failure and resolve the problem..
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-364 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OM alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Oscillator Module (OM).

Contents

OM_clockFailure15Mhz 15-366
OM_configurationMismatch 15-368
OM_frequencyOutOfRange 15-370
OM_hardwareModelMismatch 15-372
OM_inactive 15-375
OM_maintenanceRequested 15-377
OM_phaseLockLoopFailure 15-380
OM_temperatureOutOfRange 15-382
OM_underTemperature 15-384

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-365
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_clockFailure15Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_clockFailure15Mhz alarm.

Description
The 15 MHz clock signal from the Oscillator Module (OM) has been lost.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Calls on the whole Node B will drop.

Automatic corrective actions


The OM and CTU are reset and re-initialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the Oscillator Module is mounted properly in the shelf.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-366 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_clockFailure15Mhz
procedures

...................................................................................................................................................................................................

4 At the Node B, make sure that the cabling between the Oscillator Module and the I/O
panel is OK.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

7 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

8 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

11 At the Node B, replace the CTU.


...................................................................................................................................................................................................

12 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

13 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

14 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-367
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
15-368 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-369
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_frequencyOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_frequencyOutOfRange alarm.

Description
The frequency generated by the Oscillator Module (OM) onboard the CTU is out of
range

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure or network clock failure

System impact
Call processing may be impacted:
• Cells not available to the UE (sleeping cell)
• Handover not possible to cells of the affected NodeB
• Radio frequency being out of the assigned band

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, determine if the alarm occurs for single or multiple Node Bs.
...................................................................................................................................................................................................

2 In the case of multiple Node Bs being affected, check and repair the network clock

...................................................................................................................................................................................................................................
15-370 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_frequencyOutOfRange
procedures

...................................................................................................................................................................................................

3 In the case of a single Node B being affected, replace the OM.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-371
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_hardwareModelMismatch alarm.

Description
The detected Oscillator Module (OM) does not match the value specified.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedOMHardwareModel Go to step 2.
is incorrect,
an install of the correct hardware model is Go to step 7.
required,

...................................................................................................................................................................................................................................
15-372 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_hardwareModelMismatch
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

12 At the Node B, replace the CTU.


...................................................................................................................................................................................................

13 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the CTU object.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-373
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance OM_hardwareModelMismatch
procedures

...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-374 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OM_inactive
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_inactive alarm.

Description
The Oscillator Module (OM) is not operational.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Calls on the whole Node B will drop.

Automatic corrective actions


The OM and CTU are reset and re-initialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the Oscillator Module is mounted properly in the shelf.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-375
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance OM_inactive
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the CTU.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-376 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

OM_maintenanceRequested
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_maintenanceRequested alarm.

Description
The Oscillator Module (OM) sends a message to indicate that it can no longer
compensate for frequency shift.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
OM frequency can no longer be adjusted. Call processing may be impacted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-377
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance OM_maintenanceRequested
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check if this alarm occurs only for a single NodeB or whether it
occurs for several NodeBs belonging to the same part of the network .

If... Then...
in case of a single NodeB the carry out the fault clearance procedure as defined
OM is likely to be defective. Go to step 2.
Otherwise the network timing
might be out of sync.
In case of several NodeBs check and repair the network clock.
belonging to the same part of the
network,

...................................................................................................................................................................................................

2 At the OMC-UPS, reset the CTU object to initialize the Ocillator Module.
Use the reset type type0 to trigger a software reset.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to initialize the Ocillator Module.
Use the reset type type1 to trigger a power cycle.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the Node B, make sure that the Oscillator Module is mounted properly in the shelf.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object to initialize the Oscillator Module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

7 At the Node B, replace the Oscillator Module.

....................................................................................................................................................................................................................................
15-378 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_maintenanceRequested
procedures

...................................................................................................................................................................................................

8 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

11 At the Node B, replace the CTU.


...................................................................................................................................................................................................

12 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

13 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

14 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-379
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_phaseLockLoopFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_phaseLockLoopFailure alarm.

Description
The Oscillator Module Phase Lock Loop failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Clock synchronization problem.

System impact
Calls on the whole Node B will drop.

Automatic corrective actions


The OM and CTU are reset and re-initialize autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the Oscillator Module is mounted properly in the shelf.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-380 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_phaseLockLoopFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the CTU.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-381
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_temperatureOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_temperatureOutOfRange alarm.

Description
The Oscillator Module temperature sensor detected that the temperature has exceeded
the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Probable causes are:
• Defective heater on OM.
• Environmental temperature too high.

System impact
Calls on the whole Node B will drop.

Automatic corrective actions


• The clock is turned off, when the alarm is raised.
• The clock is turned on, when the alarm is cleared.
• The CTU and OM are isolated if the number of alarm occurences per hour reach a
preset threshold

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS check for Frame and DigitalShelfFan alarms and perform the fault
clearance procedure for these alarms.
...................................................................................................................................................................................................................................
15-382 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_temperatureOutOfRange
procedures

If the temperatureOutOfRange alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the Node B, make sure that the system is operating within its operational
temperature.
If the temperatureOutOfRange alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module,
if the temperatureOutOfRange alarm has been reported several times and so the CTU
and OM have been isolated
If the alarm is cleared and not reported again, the procedure is completed
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the CTU.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-383
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

OM_underTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the OM_underTemperature alarm.

Description
The Oscillator Module temperature sensor detected that the temperature is below the
specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Probable causes are:
• Defective heater on OM.
• Environmental temperature too low.

System impact
Calls on the whole Node B will drop.

Automatic corrective actions


• The clock is turned off, when the alarm is raised.
• The clock is turned on, when the alarm is cleared.
• The CTU and OM are isolated if the number of alarm occurences per hour reach a
preset threshold

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS check for Frame alarms and perform the fault clearance procedure
for these alarms.
...................................................................................................................................................................................................................................
15-384 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance OM_underTemperature
procedures

If the underTemperature alarm is cleared, the procedure is completed


...................................................................................................................................................................................................

2 At the Node B, make sure that the system is operating within its operational
temperature.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CTU object to reset and re-initialize the Oscillator Module,
if the underTemperature alarm has been reported several times and so the CTU and
OM have been isolated.
If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

5 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the CTU.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU object


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-385
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RETActuator alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the RET Actuator alarms.

Contents

RETActuator_actuatorJam 15-387
RETActuator_calibrationLost 15-389
RETActuator_communicationFailure 15-391
RETActuator_deviceTypeMismatch 15-393
RETActuator_hardwareFailure 15-394
RETActuator_positionLost 15-396
RETActuator_softwareFailure 15-398
RETActuator_tiltAngleOutOfRange 15-400

...................................................................................................................................................................................................................................
15-386 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_actuatorJam
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_actuatorJam alarm.

Description
Actuator jam has been detected.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
RET Actuator is stuck. The alarm does not imply that the position or calibration has
been lost.

System impact
RET Actuator can not be moved. No impact on call processing.

Automatic corrective actions


FM triggers state change to failed. CM cyclicly tries to move the RET Actuator
slightly to free it up.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait some time (at least one hour) for automatic clearance of the
alarm.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the NodeB, replace the RET Actuator.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-387
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RETActuator_actuatorJam
procedures

...................................................................................................................................................................................................

3 At the NodeB, replace ALD Controller.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-388 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_calibrationLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_calibrationLost alarm.

Description
The RET Actuator has lost its calibration

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The RET Actuator has not completed a calibration action or calibration has been lost
due to power interruption.

System impact
Current position of actuator is not changed. The detectedElectricalTilt attribute of
RETActuator object may be incorrect. No impact on call processing.

Automatic corrective actions


FM triggers state change to failed

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

2 At the OMC-UPS, calibrate the RETActuator object.


...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-389
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RETActuator_calibrationLost
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-390 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_communicationFailure
alarm.

Description
The communication to the RET Actuator cannot be established or has been lost.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure or cabling problem

System impact
RET Actuator not operational. NodeB cyclicly tries to reconnect. No impact on call
processing

Automatic corrective actions


FM triggers state change to failed. CM cyclicly tries to reconnect to RET Actuator.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait several minutes for automatic clearance of the alarm..
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the NodeB, check cabling between the ALD Controller and the RET Actuator.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-391
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RETActuator_communicationFailure
procedures

...................................................................................................................................................................................................

3 At the NodeB, replace the RET Actuator.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-392 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_deviceTypeMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_deviceTypeMismatch
alarm.

Description
The detected device type is not a RET device.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Wrong device connected.

System impact
RETActuator not operational.

Automatic corrective actions


FM triggers state change to failed.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the NodeB, replace device in the ALD system by a RET device.


...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-393
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_hardwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_hardwareFailure alarm.

Description
A hardware failure has occured on the RET Actuator.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The RET Actuator is reset and reinitialized autonomously. During that time the actuator
is not operational.

Automatic corrective actions


FM triggers reset and reinitialization of the RET actuator.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the RET Actuator reinitialization is completed.


If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset ALDController object.


If the alarm is cleared and not reported again, the procedure is completed.

...................................................................................................................................................................................................................................
15-394 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RETActuator_hardwareFailure
procedures

...................................................................................................................................................................................................

3 At the NodeB, replace the RET Actuator.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-395
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_positionLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_positionLost alarm.

Description
The RET Actuator has lost its position.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
ALD system is unable to return a correct position value for example due to a power
failure

System impact
Current position of actuator is not changed. The detectedElectricalTilt attribute of
RETActuator object may be incorrect. No impact on call processing

Automatic corrective actions


FM triggers state change to failed.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

2 At the OMC-UPS, calibrate the RETActuator object.


...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object.

...................................................................................................................................................................................................................................
15-396 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RETActuator_positionLost
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-397
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_softwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_softwareFailure alarm.

Description
A software failure has occured on the RET actuator.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Software error.

System impact
The RET actuator is reset and reinitialized autonomously. During that time the RET
actuator is not operational. No impact on call processing.

Automatic corrective actions


FM triggers reset and reinitialization of the RET actuator.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the RET Actuator reinitialization is completed.


If the alarm is cleared and not reported again, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, check cabling between NodeB and ALD Controller.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-398 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RETActuator_softwareFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset ALDController object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-399
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RETActuator_tiltAngleOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RETActuator_tiltAngleOutOfRange
alarm.

Description
The requested tilt angle is beyond minimum or maximum electrical tilt.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Configuration problem

System impact
The RET Actuator is still operational. The RET Actuator stopped at minimum or
maximum electrical tilt. No impact on call processing.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, set correct / valid value for desiredElectricalTilt attribute of MO


Cell.

...................................................................................................................................................................................................................................
15-400 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RETActuator_tiltAngleOutOfRange
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-401
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the RFHead alarms.

Contents

RFHead_boardGenericMismatch 15-404
RFHead_clockFailure 15-406
RFHead_communicationFailure 15-407
RFHead_criticalTransmitterAlarm 15-409
RFHead_dCInputFailure 15-411
RFHead_diversityImbalance 15-412
RFHead_externalAlarmPort0 15-414
RFHead_externalAlarmPort1 15-415
RFHead_externalAlarmPort2 15-416
RFHead_externalAlarmPort3 15-417
RFHead_externalAlarmPort4 15-418
RFHead_externalAlarmPort5 15-419
RFHead_fibreLOF 15-420
RFHead_fibreLOS 15-422
RFHead_fibreRAI 15-424
RFHead_fibreSAPDefect 15-426
RFHead_fibreSigLow 15-428
RFHead_initialisationFailure 15-430
RFHead_noncriticalTransmitterAlarm 15-431
RFHead_overTemperature 15-433
RFHead_rFOverdrive 15-435
RFHead_receiver1Failure 15-436
RFHead_receiver2Failure 15-437
RFHead_receiverFailure 15-438

...................................................................................................................................................................................................................................
15-402 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Overview
procedures

RFHead_selfTestFailure 15-439
RFHead_softwareFailure 15-440
RFHead_temperatureOutOfRange 15-441
RFHead_txActivationFailure 15-443
RFHead_underTemperature 15-444
RFHead_vSWRAlarm 15-445
RFHead_warmup 15-446

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-403
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_boardGenericMismatch
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_boardGenericMismatch
alarm.

Description
The software on the RFHead could not be updated to the current version stored on the
URC, because the download failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-404 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_boardGenericMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-405
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_clockFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_clockFailure alarm.

Description
One or more digital clocks and/or the frequency reference have failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-406 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_communicationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_communicationFailure
alarm.

Description
synchronisation between the RFHead and the URC has been lost or timeout occured
during initialisation of the RFHead.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-407
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RFHead_communicationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-408 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_criticalTransmitterAlarm
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_criticalTransmitterAlarm
alarm.

Description
The RF-Head experienced a critical transmitter failure.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-409
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RFHead_criticalTransmitterAlarm
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-410 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_dCInputFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_dCInputFailure alarm.

Description
Low or high DC Input is being detected.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-411
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_diversityImbalance
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_diversityImbalance alarm.

Description
The delta between receive antenna 1 and receive antenna 2 has exceeded a specified
threshold.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-412 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_diversityImbalance
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-413
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort0
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort0 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-414 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort1
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort1 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-415
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort2
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort2 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-416 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort3
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort3 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-417
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort4
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort4 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-418 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_externalAlarmPort5
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_externalAlarmPort5 alarm.

Description
This string is derived from the externalAlarm attribute.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-419
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_fibreLOF
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_fibreLOF alarm.

Description
The master port of the previous RF Head or the slave port of this RF Head has
encountered a loss of frame.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-420 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_fibreLOF
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-421
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_fibreLOS
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_fibreLOS alarm.

Description
The master port of the previous RF Head or the slave port of this RF Head has
encountered a loss of signal.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-422 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_fibreLOS
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-423
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_fibreRAI
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_fibreRAI alarm.

Description
The master port of the previous RF Head or the slave port of this RF head has
encountered a remote alarm signal.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-424 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_fibreRAI
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-425
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_fibreSAPDefect
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_fibreSAPDefect alarm.

Description
The master port of the previous RF Head or the slave port of this RF Head has
encountered a service access point defect.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-426 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_fibreSAPDefect
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-427
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_fibreSigLow
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_fibreSigLow alarm.

Description
The master port of the previous RF head or the slave port of this RF Head has
encountered a low optical signal.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
15-428 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance RFHead_fibreSigLow
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-429
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_initialisationFailure alarm.

Description
The RFHead module failed to initialise properly.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-430 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_noncriticalTransmitterAlarm
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_noncriticalTransmitterAlarm
alarm.

Description
The RF Head experienced a minor transmitter failure.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-431
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RFHead_noncriticalTransmitterAlarm
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-432 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_overTemperature
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_overTemperature alarm.

Description
The RF head is over the operational temperature limit but the RF head is still
operational.

Default severity
Warning

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-433
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RFHead_overTemperature
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-434 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_rFOverdrive
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_rFOverdrive alarm.

Description
The RF head is being overdriven by the OCM.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-435
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_receiver1Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RFHead_receiver1Failure alarm.

Description
The RF Head is experiencing difficulty in the first receive path. A failure of the
External Rx Amplifier (TTLNA) in Rx Path 1 will also trigger this alarm.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-436 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_receiver2Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RFHead_receiver2Failure alarm.

Description
The RF Head is experiencing difficulty in the second receive path. A failure of
theExternal Rx Amplifier (TTLNA) in Rx Path 2 will also trigger this alarm.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-437
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_receiverFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_receiverFailure alarm.

Description
The RF Head is experiencing a failure on both receive paths.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-438 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_selfTestFailure alarm.

Description
Diagnostics on the RFHead have failed and operation is not possible.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-439
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_softwareFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_softwareFailure alarm.

Description
The RF Head has encountered a software failure.

Default severity
Warning

Alarm type
processingErrorAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-440 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_temperatureOutOfRange
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
Ye
This topic provides the procedure for clearing the RFHead_temperatureOutOfRange
alarm.

Description
The RF head transmitter has shut down due to critical temperature.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-441
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RFHead_temperatureOutOfRange
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-442 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_txActivationFailure
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_txActivationFailure alarm.

Description
The RF head has failed to activate the transmitter.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-443
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_underTemperature
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_underTemperature alarm.

Description
The RF Head is transmitting below its normal operating temperature.

Default severity
Warning

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-444 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RFHead_vSWRAlarm
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_vSWRAlarm alarm.

Description
VSWR level has fallen below alarm threshold.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-445
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RFHead_warmup
...................................................................................................................................................................................................................................

Purpose
Important! This managed object is not currently supported.
This topic provides the procedure for clearing the RFHead_warmup alarm.

Description
The RF Head warms up, since its components are not warm enough for operation.

Default severity
Major

Alarm type
environmentalAlarm

Root cause
TBA.

System impact
TBA.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, TBA.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-446 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Radio.

Contents

Radio_applicationInsane 15-449
Radio_boardGenericMismatch 15-450
Radio_clockFailure30_72Mhz 15-452
Radio_communicationFailure 15-455
Radio_configurationMismatch 15-457
Radio_criticalGainFailure 15-459
Radio_digitalClippingDetected 15-461
Radio_diversityImbalance 15-463
Radio_fPGAFailure 15-465
Radio_filterPanelRecordInvalid 15-467
Radio_hardwareModelMismatch 15-469
Radio_hwErrorDetectedByPlatformSw 15-471
Radio_initialisationFailure 15-473
Radio_internalGainFailure 15-475
Radio_localConfigurationFailure 15-477
Radio_lossOfDemodulatorSynthesizerSynchronisation 15-479
Radio_lossOfForwardBusLink 15-482
Radio_lossOfModulatorSynthesizerSynchronisation 15-484
Radio_lossOfPulse 15-487
Radio_lossOfReceiveSynthesizerSynchronisation 15-490
Radio_lossOfTransmitSynthesizerSynchronisation 15-493
Radio_majorGainFailure 15-496
Radio_majorPlatformSwError 15-499
Radio_majorTxSpectrumFailure 15-500

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-447
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Overview
procedures

Radio_messageThrottleOn 15-503
Radio_minorGainFailure 15-505
Radio_missingConfigurationData 15-508
Radio_missingDelayCalibrationData 15-510
Radio_overTemperature 15-512
Radio_portMapInvalid 15-514
Radio_rFOverdrive 15-516
Radio_rFPathMismatch 15-518
Radio_resyncOfPulse 15-520
Radio_rx1PathFaultDetected 15-523
Radio_rx2PathFaultDetected 15-525
Radio_samplingReceiverFailure 15-527
Radio_selfTestFailure 15-529
Radio_synthesizerFailure122Mhz 15-531
Radio_synthesizerFailure15Mhz 15-533
Radio_tDUCommunicationFailure 15-535
Radio_toneGeneratorFailure 15-537
Radio_transmitGainLimitExceeded 15-539
Radio_transmitterSwitchFailure 15-542
Radio_transmitterSwitchOff 15-544
Radio_txActivationMalfunction 15-546
Radio_underTemperature 15-548

....................................................................................................................................................................................................................................
15-448 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_applicationInsane
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_applicationInsane alarm.

Description
The Radio application software is not functioning properly.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Software program error.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio resets and initializes autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-449
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_boardGenericMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_boardGenericMismatch alarm.

Description
The software version on the Radio does not match with the current version stored,
because software download failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The software on the Radio could not be updated, because the download to the Radio
failed.

System impact
The Radio can not be initiated to service. No calls in this cell are possible.

Automatic corrective actions


The Radio is reset and download of software to the Radio is started again.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, fallback to previous NodeB software if appropriate

...................................................................................................................................................................................................................................
15-450 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_boardGenericMismatch
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object to update the software on the Radio.
If the alarm is cleared, the procedure is completed
...................................................................................................................................................................................................

4 At the OMC-UPS, check the state of the current NodeB software version via RMT. If
the state is not GOOD, reset the NodeB object
If the alarm is cleared, the procedure is completed
Result: The NodeB automatically downloads missing/corrupted software files from
the FTP server (OMC) and updates the software on the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

6 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

7 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-451
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_clockFailure30_72Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_clockFailure30_72Mhz alarm.

Description
The Radio detected loss of the 30.72Mhz clock.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem due to a CTU failure or to the clock circuitry in the Radio.

System impact
All calls in the cell that the Radio serves are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-452 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_clockFailure30_72Mhz
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the following:

If... Then...
This is the only Radio that is Go to step 3.
reporting an error,
There are also CTU or Oscillator Go to step 7.
Module errors,

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

8 At the Node B, replace the CTU.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

12 At the Node B, replace the Oscillator Module.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-453
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_clockFailure30_72Mhz
procedures

...................................................................................................................................................................................................

13 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-454 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_communicationFailure alarm.

Description
Heartbeat synchronization between the Radio and the URC has been lost or timeout
occured during initialization or cyclic audit of the Radio.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.
• Backplane EEPROM not accessible

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed. If the alarm is not
cleared within 5 minutes, the initialisation has failed.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-455
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_communicationFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, solve any other error which would cause this alarm as a side effect.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the Node B, make sure that the Radio is mounted properly in the frame.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, check for additional alarms, for example SelfTestFailure or


InitialisationFailure. Perform a reset action of the Radio object in order to reset and
initialize the Radio.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

8 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

9 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-456 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-457
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-458 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_criticalGainFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_criticalGainFailure alarm.

Description
Radio gain control algorithm is not able to initialize correctly.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio will be reset and intialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

3 At the Node B, replace the Radio.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-459
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_criticalGainFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure)
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-460 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_digitalClippingDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_digitalClippingDetected alarm.

Description
The Radio reports digital clipping.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Defective UCU.

System impact
Call capacity in the cell served by the Radio is reduced.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock all UCUs except of the UCU to be tested.


...................................................................................................................................................................................................

2 Make test calls to establish if the unlocked UCU is defective.

If ... then ...


the alarm is not cleared or raised again continue with step 3
the unlocked UCU is defective

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-461
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_digitalClippingDetected
procedures

If ... then ...


the alarm is cleared unlock the UCU and continue with step
8

...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the other UCUs.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the defective UCU.


...................................................................................................................................................................................................

5 At the NodeB, replace the defective UCU


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the UCU


...................................................................................................................................................................................................

7 At the NodeB, unlock the UCU


...................................................................................................................................................................................................

8 At the OMC-UPS, check if all UCUs have been tested:

If ... then ...


all UCUs have been tested continue with step 9
all UCUs have not been tested return to step 1

...................................................................................................................................................................................................

9 Carry out several test calls in order to verify that the alarm is cleared
...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-462 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_diversityImbalance
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_diversityImbalance alarm.

Description
The delta between receive antenna 1 and receive antenna 2 has exceeded a specified
threshold.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Probable causes are:
• Cable or connector problems
• Antenna problems
• Receiver failure.

System impact
The cell is degraded.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for ExtRxAmp, Filter, RxAmp and Radio alarms and perform
fault clearance procedure related to these alarms.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-463
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_diversityImbalance
procedures

...................................................................................................................................................................................................

2 At the Node B, make sure that the receive path (antenna, RF cable, filter unit, Radio
and cabling) is working properly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-464 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_fPGAFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_fPGAFailure alarm.

Description
One of the Field Programmable Gate Arrays on the Radio has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
No new calls are accepted, existing calls are dropped.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

2 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-465
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_fPGAFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-466 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_filterPanelRecordInvalid
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_filterPanelRecordInvalid
alarm.

Description
One or all filter panel records used for the configuration of the Radios are invalid.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Port map might not match filter panel configuration
• Filter panel might be not connected
• Local filter panel EEPROM data corrupt.

System impact
The radio cannot be configured properly. The Cell that is supported by this radio
cannot be used.

Automatic corrective actions


The Radio is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, use the remote RMT to make sure that the backplane EEPROM
data is OK.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-467
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_filterPanelRecordInvalid
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, clear any filter panel alarms.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the Node B, make sure that all filter panels are mounted correctly.
...................................................................................................................................................................................................

6 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 Replace the indicated filter panels.


...................................................................................................................................................................................................

8 At the OMC-UPS, reset the Radio object to initialize the Radio.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-468 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_hardwareModelMismatch
alarm.

Description
The detected radio hardware model does not match the value specified.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedRadioHardware- Go to step 2.
Model is incorrect,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-469
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_hardwareModelMismatch
procedures

If ... then ...


an install of the correct hardware model is Go to step 7..
required,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

7 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

8 Important! Radio replacement has service impact on NodeB


At the Node B, replace the Radio module.
...................................................................................................................................................................................................

9 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-470 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_hwErrorDetectedByPlatformSw
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_hwErrorDetectedByPlat-
formSw alarm.

Description
The platform that supports the application software has detected a potentially
unrecoverable hardware fault.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure

System impact
All calls in the cell supported by this Radio will be dropped.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-471
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_hwErrorDetectedByPlatformSw
procedures

...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-472 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_initialisationFailure alarm.

Description
The Radio failed to initialize.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The Radio cannot be initiated to service. No calls in this cell are possible.

Automatic corrective actions


The Radio is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the Radio is mounted correctly.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-473
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_initialisationFailure
procedures

...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-474 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_internalGainFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_internalGainFailure alarm.

Description
Radio internal gain is different from the expected gain.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Hardware failure.

System impact
Output power variance is to be expected.The transmit spectrum may break mask.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for minorGainFailure and majorGainFailure alarms of the


Radio.

If... Then...
If one of these alarms is pending replacement of the Radio is required, since the
Radio will not transmit at the correct power level.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-475
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_internalGainFailure
procedures

If... Then...
If one of these alarms is not replacement of the Radio is recommended, but not
pending urgently required, since the Radio will still
transmits at the correct power level.

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

3 At the Node B, replace the Radio.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-476 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_Radio_localConfiguration-
Failure alarm.

Description
The configuration conflicts with local configuration data..

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-477
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_localConfigurationFailure
procedures

Ensure the following are checked:


• BTS Primary RF Path Map
• Antenna Path Descriptor Record
• BTS RF Test Path Map.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-478 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfDemodulatorSynthesizerSynchronisation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfDemodulatorSynthe-
sizerSynchronisation alarm.

Description
The demodulator is out of synchronization which causes the Rx signal to be out of
lock.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-479
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_lossOfDemodulatorSynthesizerSynchronisation
procedures

...................................................................................................................................................................................................

2 If... Then...
There are also synthesizer errors Go to step 3.
on other Radios
There are no other synthesizer Go to step 11.
errors.

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

12 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

13 At the OMC-UPS, reset the Radio object.


....................................................................................................................................................................................................................................
15-480 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfDemodulatorSynthesizerSynchronisation
procedures

...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-481
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfForwardBusLink
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfForwardBusLink alarm.

Description
The Radio reported loss of the forward bus link.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for additional alarms, for example SelfTestFailure or


InitialisationFailure. Perform a reset of the Radio object in order to reset and initialize
the Radio.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-482 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfForwardBusLink
procedures

...................................................................................................................................................................................................

3 At the Node B, make sure that the timing (clock source, cables, Oscillator Module) to
the Radio are OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

5 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

6 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-483
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfModulatorSynthesizerSynchronisation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfModulatorSynthe-
sizerSynchronisation alarm.

Description
The modulator is out of synchronization which causes the Tx signal to be out of lock.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If... Then...
There are also synthesizer errors Go to step 3.
on other Radios.

...................................................................................................................................................................................................................................
15-484 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfModulatorSynthesizerSynchronisation
procedures

If... Then...
There are no other synthesizer Go to step 11.
errors.

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

12 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

13 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the Radio object.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-485
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_lossOfModulatorSynthesizerSynchronisation
procedures

...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-486 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfPulse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfPulse alarm.

Description
The 10 mSec pulses are not detected by the Radio.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-487
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_lossOfPulse
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the following:

If... Then...
This is theonlyRadio reporting Go to step 3.
this alarm,
This is not the only Radio Go to step 8.
reporting this alarm,

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

8 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

9 At the Node B, replace the CTU.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

12 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

13 At the Node B, replace the Oscillator Module.

....................................................................................................................................................................................................................................
15-488 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfPulse
procedures

...................................................................................................................................................................................................

14 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

15 At the OMC-UPS, unlock the CTU object.


...................................................................................................................................................................................................

16 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-489
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfReceiveSynthesizerSynchronisation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfReceiveSynthesiz-
erSynchronisation alarm.

Description
The Rx signal is no longer synchronized.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If... Then...
There are also synthesizer errors Go to step 3.
on other Radios.

...................................................................................................................................................................................................................................
15-490 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfReceiveSynthesizerSynchronisation
procedures

If... Then...
There are no other synthesizer Go to step 11.
errors.

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

12 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

13 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the Radio object.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-491
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_lossOfReceiveSynthesizerSynchronisation
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-492 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_lossOfTransmitSynthesizerSynchronisation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_lossOfTransmitSynthesiz-
erSynchronisation alarm.

Description
The Tx signal is no longer tuned. This indicates a clocking error.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed..


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If... Then...
There are also synthesizer errors Go to step 3.
on other Radios.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-493
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_lossOfTransmitSynthesizerSynchronisation
procedures

If... Then...
There are no other synthesizer Go to step 11.
errors.

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

4 At the Node B, replace the CTU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the CTU object


...................................................................................................................................................................................................

8 At the Node B, replace the Oscillator Module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the CTU object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

12 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

13 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the Radio object.

....................................................................................................................................................................................................................................
15-494 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_lossOfTransmitSynthesizerSynchronisation
procedures

...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-495
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_majorGainFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_majorGainFailure alarm.

Description
The Radio’s internal attenuators are at their limit or the Radio gain control algorithm is
not able to initialize correctly.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Cabling problem or hardware failure.

System impact
Radio output power variance is to be expected. The transmit spectrum may break
mask.

Automatic corrective actions


If the Radio gain control algorithm failed to initialize correctly during startup, it falls
back to local loop and remains in this mode, until the Radio is reset
If attenuation is not available, attenuation adjustment stops.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for internalGainFailure alarm of the Radio and perform the
fault clearance procedure related to this alarm.
If the majorGainFailure alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-496 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_majorGainFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, extract the additional information (CAI) from the additional text of
the alarm:

If... Then...
CAI=0XE: “transmit gain indicates at startup of Radio, that the gain control
out of range” algorithm has failed to lock resulting in a fallback
to local loop. Go to step 3.
CAI=0X8: “attenuation not indicates that attenuators have run out of
available – internal fault” adjustment by a large amount due to a fault
internal to the Radio. Go to step 9.
CAI=0X9: “attenuation not indicates that attenuators have run out of
available – external adjustment by a large amount due to a fault
fault” external to the Radio. Go to step 14.
CAI=0XA: “attenuation not indicates that the attenuators have run out of
available – unknown fault” adjustment by a large amount due to an unknown
fault. First run the fault clearance procedure for the
“attenuation not available – external fault” and if
the problem still persists, the fault clearance
procedure for the “attenuation not available –
internal fault”.

...................................................................................................................................................................................................

3 At the OMC-UPS, check for criticalGainFailure alarm of the Radio and perform fault
clearance procedure related to this alarm.
If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, check for TxAmp alarms and perform the fault clearance procedures
related to these alarms.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the Node B, check cabling of Radio and RF path.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the Radio object.


If the majorGainFailure alarm is cleared, the procedure is completed.
....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-497
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_majorGainFailure
procedures

...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure)
...................................................................................................................................................................................................

9 At the OMC-UPS, check for overTemperature alarms of the Radio and perform the
fault clearance procedure of these alarms.
If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

11 At the NodeB, replace the Radio.


...................................................................................................................................................................................................

12 At the OMC-UPS, unlock the Radio.


...................................................................................................................................................................................................

13 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure).
...................................................................................................................................................................................................

14 At the OMC-UPS, check for TxAmp alarms and perform the fault clearance procedures
related to these alarms.
If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

15 At the Node B, check cabling of Radio and RF path.


If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

16 At the NodeB, perform a recalibration of the RF-path related to this Radio.


If the majorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

17 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure).
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-498 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_majorPlatformSwError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_majorPlatformSwError alarm.

Description
The platform code (USL) which supports the application software has reported a major
error

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The Radio platform SW detected an error condition that can only be cleared by a
restart of the application software.

System impact
All Calls in the cell supported by this Radio will be dropped.

Automatic corrective actions


The Radio performs a reset and the application software gets restarted autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No immediate action is required. Contact Lucent customer support for more in-depth
investigation of this fault.
END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-499
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_majorTxSpectrumFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_majorTxSpectrumFailure
alarm.

Description
Spectrum management algorithm detected a major failure.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Spectrum management training was required, for one of the following reasons:
• An amplifier module has been detected (initial startup or replacement), for which
training has not been completed.
• The maximum transmission power has been increased.
• The spectrum management coefficients are out of date.
• The transmission frequency has been changed.
Spectrum management failed for one of the following reasons:
• Failure of the sampling receiver circuit of the Radio.
• Failure of the feedback path between the filter panel and the Radio.

System impact
Radio may not satisfy 3GPP spectrum mask.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-500 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_majorTxSpectrumFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

5 At the Node B, check the feedback cable from the filter unit to the Radio.
...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the TxAmp object related to the Radio object.
...................................................................................................................................................................................................

8 At the Node B, replace the amplifier module


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

12 At the Node B, replace the Radio.


...................................................................................................................................................................................................

13 At the OMC-UPS, reset the Radio object.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-501
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_majorTxSpectrumFailure
procedures

...................................................................................................................................................................................................

14 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

15 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure)
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-502 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_messageThrottleOn
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_messageThrottleOn alarm.

Description
Message throttling has been activated because too many minor errors are being sent by
the Radio.

Default severity
Critical

Alarm type
qualityofServiceAlarm

Root cause
Resource is at or is nearing its capacity.

System impact
The Radio performs a reset. All calls in this cell are lost.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for other Radio alarms and perform fault clearance
procedures for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-503
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_messageThrottleOn
procedures

...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-504 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_minorGainFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_minorGainFailure alarm.

Description
Minor gain failure indicating an RF path fault outside of the Radio or a large
instantaneous gain error. Transmit port attenuator has been adjusted beyond allowable
limit to compensate for gain change external to the Radio, or the Radio has detected a
change in loop gain beyond acceptable limits.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Probable causes are:
• RF path fault outside of the Radio.
• Large instantaneous gain change within the Radio.

System impact
Output power variance is to be expected. The transmit spectrum may break mask.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for internalGainFailure alarm of the Radio and perform the
fault clearance procedure related to this alarm.
If the minorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-505
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_minorGainFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for alarms of the backhaul interface (E1/T1, IubInterface,
IMAGroup) and perform the fault clearance procedure related to these alarms.
If the minorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, extract the additional information (CAI) from the additional text of
the alarm:

If... Then...
CAI=0X7: “external gain indicates, that the Radio has identified a gradual
error” gain error external to the Radio greater than a
threshold and has stopped adjusting the attenuators.
Go to step 4.
CAI=0XB: “large indicates, that the Radio has identified a sudden
instantaneous gain error – change of gain internal to the Radio and has
internal stopped adjusting the attenuators. Go to step 7.
fault”
CAI=0XC: “large indicates, that the Radio has identified a sudden
instantaneous gain error – change of gain external to the Radio and has
external stopped adjusting the attenuators. Go to step 12
fault”
CAI=0XD: “large indicates, that the Radio has identified a sudden
instantaneous gain error – change of gain due to an unknown fault. First run
unknown the fault clearance procedures for the “large
fault” instantaneous gain error – external fault” and if the
problem still persists, the fault clearance procedure
for the “large instantaneous gain error – internal
fault”.

...................................................................................................................................................................................................

4 At the OMC-UPS, check for TxAmp alarms and perform the fault clearance procedures
related to these alarms.
If the minorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 In case of NodeB installation and first startup: At the NodeB, perform a recalibration
of the RF-path related to the Radio
If the minorGainFailure alarm is cleared, the procedure is completed.

....................................................................................................................................................................................................................................
15-506 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_minorGainFailure
procedures

...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure).
...................................................................................................................................................................................................

7 At the OMC-UPS, reset the Radio object


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

9 At the NodeB, replace the Radio.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure).
...................................................................................................................................................................................................

12 At the OMC-UPS, check for TxAmp alarms and perform the fault clearance procedures
related to these alarms.
If the minorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

13 At the Node B, check cabling of Radio and RF path.


If the minorGainFailure alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

14 If the problem persists, contact Alcatel-Lucent customer support.


Provide the gain control information reported by the alarm (Tx port state structure).
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-507
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_missingConfigurationData
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_missingConfigurationData
alarm.

Description
The configuration conflicts with local configuration data..

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
15-508 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_missingConfigurationData
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-509
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_missingDelayCalibrationData
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_missingDelayCalibrationData
alarm.

Description
Delay calibration data needed for round trip time measurement is missing.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Delay calibration data is missing in the backplane, filter panel, or Radio.

System impact
Round trip time measurement not available towards the RNC. Location services
accuracy degraded. Normal call processing is not affected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check backplane and filter panel EEPROM data via RMT and correct
as appropriate.

...................................................................................................................................................................................................................................
15-510 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_missingDelayCalibrationData
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-511
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_overTemperature alarm.

Description
The Radio temperature sensor detected a temperature above the specifications limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
High temperature.

System impact
All calls are dropped immediately. Call processing on the cell is blocked, so no new
calls are accepted.

Automatic corrective actions


The Radio is isolated if the number of alarm occurences per hour reach a preset
threshold.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Frame, AmpShelfFan and DigitalShelfFan alarms related
to heat management system or fan problems, and perform the fault clearance procedure
for these alarms.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-512 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_overTemperature
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object, if the overTemperature alarm has been
reported several times and so the Radio has been isolated. If the alarm has been
cleared and is not reported again, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-513
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_portMapInvalid
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_portMapInvalid alarm.

Description
The Radio port map contained in the backplane’s EEPROM is invalid.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The port map contained in the backplane EEPROM is invalid.

System impact
The Radio cannot be configured properly. The Cell that is supported by this Radio
cannot be used.

Automatic corrective actions


The Radio is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, use the remote RMT to make sure that the backplane EEPROM
data is OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object to initialize the Radio.

...................................................................................................................................................................................................................................
15-514 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_portMapInvalid
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-515
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_rFOverdrive
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_rFOverdrive alarm.

Description
The UMTS Channel Unit (UCU) is driving the Radio with a too strong digital signal.
As a result there will be RF clipping and Bit Error Rates.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Excessive input power.
Probable causes are:
• Configuration error
• Failure on Radio

System impact
Cell is degraded and calls may drop.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the (RF power) configuration of the Radio and correct if necessary.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-516 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_rFOverdrive
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for additional alarms, for example SelfTestFailure or


InitialisationFailure. Perform a reset action of the Radio object to reset and initialize
the Radio.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

7 If the problem persists, request Alcatel-Lucent customer support to check why the
Radio is operating at a higher than normal power level.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-517
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_rFPathMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_rFPathMismatch alarm.

Description
The hardware of the RF-path does not fit together.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Provisioning of inconsistent hardware:
• The combination of TTLNA and DAS equipment is not supported.
• The combination of Radio and Amplifier board is not supported.
• Filter, Radio and Amplifier boards do not support the same band class.
• The supported frequency range does not fit into a known frequency band.

System impact
No traffic possible on associated cell.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, extract detailed information about the mismatch from the
additionalText of the alarm.

...................................................................................................................................................................................................................................
15-518 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_rFPathMismatch
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check TTLNA and DAS configuration if required.


...................................................................................................................................................................................................

3 At the Node B, exchange Radio, Filter and/or Amplifier hardware as required.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-519
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_resyncOfPulse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_resyncOfPulse alarm.

Description
Resyncronization of 10 millisecond pulse occurred. Radio lost UL and DL data for a
short time.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
No impact on service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


No immediate action required, if the alarm is reported repeatedly for more than one
Radio, it is recommended to check and replace the CTU if required.

...................................................................................................................................................................................................................................
15-520 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_resyncOfPulse
procedures

Perform the following steps to clear the alarm:


...................................................................................................................................................................................................

1 At the OMC-UPS, carry out the following steps:

If... Then...
This alarm is reported repeatedly Go to step 2.
for more than one Radio,
Otherwise, Go to step 5.

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

3 At the Node B, replace the CTU.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the CTU object


...................................................................................................................................................................................................

5 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the Radio object to initialize the Radio.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the Radio object.


If the alarm is not reported again, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

9 At the Node B, replace the Radio.


...................................................................................................................................................................................................

10 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

11 At the OMC-UPS, unlock the Radio object.


If the alarm is not reported again, the procedure is completed.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-521
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_resyncOfPulse
procedures

...................................................................................................................................................................................................

12 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-522 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_rx1PathFaultDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_rx1PathFaultDetected.

Description
This alarm indicates a hardware failure in the first Rx Path chain.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Dysfunction of the first Rx path is to be expected.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, ensure that the first receive path (antenna, RF cable, filter unit, radio
and cabling) is working properly.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-523
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_rx1PathFaultDetected
procedures

...................................................................................................................................................................................................

2 If the problem persists, request Alcatel-Lucent customer support


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-524 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_rx2PathFaultDetected
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_rx2PathFaultDetected.

Description
This alarm indicates a hardware failure of the second Rx Path chain.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Dysfunction of the second Rx path is to be expected.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, ensure that the second receive path (antenna, RF cable, filter unit,
radio and cabling) is working properly.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-525
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_rx2PathFaultDetected
procedures

...................................................................................................................................................................................................

2 If the problem persists, request Alcatel-Lucent customer support


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-526 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_samplingReceiverFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_samplingReceiverFailure
alarm.

Description
Radio software failed to read data from the sampling receiver circuit.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Hardware failure.

System impact
No impact on service. Spectrum management will be impacted when a measurement is
required.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


No immediate action is required but Radio replacement is recommended.
Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

2 At the Node B, replace the Radio.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-527
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_samplingReceiverFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

5 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-528 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_selfTestFailure alarm.

Description
The Radio failed the Board Level Self Test (BLST).

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The Radio cannot be initiated to service. No calls in this cell are possible.

Automatic corrective actions


The Radio is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the Radio is mounted correctly.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-529
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_selfTestFailure
procedures

...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-530 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_synthesizerFailure122Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_synthesizerFailure122Mhz
alarm.

Description
The 122 Mhz synthesizer failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
The Radio is reset and reinitialized autonomously.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the cabling on the Oscillator Module and CTU is OK.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object to initialize the Radio.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-531
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_synthesizerFailure122Mhz
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

4 At the OMC-UPS, check for and clear any Oscillator Module or CTU alarms.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

7 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

8 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-532 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_synthesizerFailure15Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_synthesizerFailure15Mhz
alarm.

Description
The 15 MHz synthesizer failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
All calls in this cell are dropped.

Automatic corrective actions


The Radio is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the cabling on the Oscillator Module and CTU is OK.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the Radio object to initialize the Radio.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-533
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_synthesizerFailure15Mhz
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

4 At the OMC-UPS, check for and clear any Oscillator Module and CTU alarms.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object to initialize the Radio.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

7 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

8 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-534 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_tDUCommunicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_tDUCommunicationFailure
alarm.

Description
The Radio is unable to reach the Test and Diagnostic Unit (TDU).

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The Radio will reduce its transmit power. Call capacity in the cell is reduced.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for other Radio objects also reporting this error.

If... Then...
More Radio objects reporting this Go to step 2.
error,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-535
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_tDUCommunicationFailure
procedures

If... Then...
Only this Radio object reporting Go to step 6.
this error,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

3 At the Node B, replace the TDU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

7 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

8 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-536 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_toneGeneratorFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_toneGeneratorFailure alarm.

Description
The onboard tone generator circuit has failed during execution of an Rx antenna test.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Hardware failure.

System impact
No impact on service. Result of Rx antenna test is invalid, further Rx antenna tests are
rejected

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object to initialize the Radio and clear the alarm.
...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-537
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_toneGeneratorFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, start another Rx antenna test..


If the alarm is not reported again, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the Radio object


...................................................................................................................................................................................................

6 At the Node B, replace the Radio.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

9 At the OMC-UPS, start another Rx antenna test..


If the alarm is not reported again, the procedure is completed.
...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-538 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

Radio_transmitGainLimitExceeded
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_transmitGainLimitExceeded
alarm.

Description
The transmit close loop gain control is out of range.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Probable causes are:
• Transmitter failure
• TDU power detector failure
• Cabling problem.

System impact
Call capacity in the cell served by this Radio is reduced.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 If... Then...
This alarm is reported by one Go to step 2.
Radio,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-539
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance Radio_transmitGainLimitExceeded
procedures

If... Then...
This alarm is reported by more Go to step 9.
Radios,

...................................................................................................................................................................................................

2 At the Node B, make sure that the cabling between the Radio, transmit power
amplifier, filter and the TDU is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, solve any TxAmp alarms.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

5 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

6 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

9 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

10 At the Node B, replace the TDU.


...................................................................................................................................................................................................

11 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

12 At the OMC-UPS, unlock the TDU object.

....................................................................................................................................................................................................................................
15-540 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_transmitGainLimitExceeded
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

13 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-541
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_transmitterSwitchFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_transmitterSwitchFailure
alarm.

Description
The activation/deactivation of the radio transmitter has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Radio will be reset.and initialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Radio reinitialization has been completed.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

3 At the Node B, replace the Radio.


...................................................................................................................................................................................................................................
15-542 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_transmitterSwitchFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-543
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_transmitterSwitchOff
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_transmitterSwitchOff alarm.

Description
This alarm indicates that the Radio associated with this cell is currently turned off. The
switch on the front panel of the radio circuit pack is set off.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
Transmitter failure.

System impact
This is not really an indication of a problem but a status report. All calls in this cell
are lost.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, turn the Tx front panel switch on the Radio to the On position.

...................................................................................................................................................................................................................................
15-544 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_transmitterSwitchOff
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-545
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_txActivationMalfunction
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_txActivationMalfunction
alarm.

Description
The Radio does not have its transmitter turned on, or can not activate its transmitter.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Radio transmitter switched off due to hardware or software problems.

System impact
The cell served by this Radio is not operational. No traffic in this cell is possible.

Automatic corrective actions


The Radio is reset and reinitialized.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait for Radio reinitialization has been completed


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


...................................................................................................................................................................................................................................
15-546 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_txActivationMalfunction
procedures

At the Node B, replace the Radio.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-547
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

Radio_underTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Radio_underTemperature alarm.

Description
The Radio temperature sensor detected a temperature below the specifications limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Low temperature.

System impact
All calls are dropped immediately. Call processing on the cell is blocked, so no new
calls are accepted.

Automatic corrective actions


The Radio is isolated if the number of alarm occurences per hour reach a preset
threshold.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Frame, AmpShelfFan and DigitalShelfFan alarms related
to heat management system or fan problems, and perform the fault clearance procedure
for these alarms.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-548 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance Radio_underTemperature
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, reset the Radio object, if the underTemperature alarm has been
reported several times and so the Radio has been isolated. If the alarm has been
cleared and is not reported again, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the Radio object


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-549
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

RxAmp alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the LNA.

Contents

RxAmp_equipmentFault 15-551
RxAmp_initialisationFailure 15-553

...................................................................................................................................................................................................................................
15-550 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RxAmp_equipmentFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RxAmp_equipmentFault alarm.

Description
One LNA in a filter panel failed. As a result the radio functionality will be impaired,
but still be present.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The system will be impacted as indicated below:
• Affected cells are degraded if the alarm is pending and the operational state of the
RxAmp MO is disabled.
• If this was the only RxAmplifier or the last RxAmplifier which served the cell, the
cell is disabled.
• In case of a intermittent fault condition, the alarm is only cleared if the fault did
not occur again within 3 hours.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-551
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RxAmp_equipmentFault
procedures

...................................................................................................................................................................................................

2 At the Node B, replace the filter unit of the RxAmplifier (the LNA is part of the filter
unit).
...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object


...................................................................................................................................................................................................

4 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-552 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

RxAmp_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the RxAmp_initialisationFailure alarm.

Description
The RxAmp has failed to initialize.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The filter can not be initiated to service. The call capacity on this cell is decreased. If
no filter unit associated with this cell can be initiated to service, call processing on this
cell is blocked.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

2 At the Node B, replace the filter unit.


...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the Radio object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-553
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance RxAmp_initialisationFailure
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-554 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the STM1OC3Port alarms.

Contents

STM1OC3Port_linkFailureAIS_L 15-556
STM1OC3Port_linkFailureAIS_P 15-558
STM1OC3Port_linkFailureLOF 15-560
STM1OC3Port_linkFailureLOP_P 15-562
STM1OC3Port_linkFailureLOS 15-564
STM1OC3Port_linkFailurePLM_P 15-566
STM1OC3Port_linkFailureRDI_L 15-568
STM1OC3Port_linkFailureRDI_P 15-570
STM1OC3Port_linkFailureSLU_P 15-572
STM1OC3port_localConfigurationFailure 15-574
STM1OC3Port_pathTraceMismatch 15-576
STM1OC3Port_signalDegraded_L 15-578
STM1OC3Port_signalDegraded_P 15-580
STM1OC3Port_signalFailed_L 15-582
STM1OC3Port_signalFailed_P 15-584

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-555
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureAIS_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureAIS_L
alarm.

Description
An Alarm Indication Signal Line (AIS-L) failure has occured on the ATM
(STM1/OC3) link connection

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Transmission problem in the upstream link (for example, loss of frame, loss of signal,
etc).

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.


...................................................................................................................................................................................................................................
15-556 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureAIS_L
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-557
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureAIS_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureAIS_P
alarm.

Description
An Alarm Indication Signal Path (AIS-P) failure has occured on the ATM (STM1/OC3)
link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Transmission problem upstream of the STM-1/OC-3 path.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-558 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureAIS_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-559
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureLOF
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureLOF
alarm.

Description
A Loss of Frame (LOF) failure has occured on the ATM (STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
STM1/OC3 line is not synchronised to the transmission link. Framing of the
STM1/OC3 signal is corrupt

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-560 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureLOF
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-561
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureLOP_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureLOP_P
alarm.

Description
A Loss of Pointer Path (LOP-P) failure has occured on the ATM (STM1/OC3) link
connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Pointer information missing or wrong.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-562 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureLOP_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-563
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureLOS
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureLOS
alarm.

Description
A Loss of Signal (LOS) failure has occured on the ATM (STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Loss of signal due to link interruption or equipment malfunction.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-564 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureLOS
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-565
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailurePLM_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailurePLM_P
alarm.

Description
A Payload Label Mismatch Path (PLM-P) failure has occured on the ATM
(STM1/OC3) link connection

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Payload label of a path is corrupted.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-566 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailurePLM_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-567
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureRDI_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureRDI_L
alarm.

Description
A Remote Defect Indication Line (RDI-L) failure has occured on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Link problem at the remote end of the STM1/OC3 line..

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-568 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureRDI_L
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-569
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureRDI_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureRDI_P
alarm.

Description
A Remote Defect Indication Path (RDI-P) failure has occured on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Link problem at the remote end of the STM1/OC3 path..

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-570 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureRDI_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-571
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_linkFailureSLU_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_linkFailureSLU_P
alarm.

Description
The received STM1/OC3 signal label is set to unequipped. Most likely the signal label
has been corrupted or not properly set at the source or in the upstream transmission
equipment.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Signal label corrupted or not properly set at the source or in the upstream transmission
equipment.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
15-572 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_linkFailureSLU_P
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-573
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3port_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
STM1OC3port_localConfigurationFailure alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
The STM/OC3 link is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, use the RMT tool to check the Trunk Group Member parameters
Configure the parameters if required.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-574 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3port_localConfigurationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-575
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_pathTraceMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_pathTraceMismatch
alarm.

Description
There is a mismatch between the received J1 path trace and the expected J1 sequence.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
J1 path trace mismatch in case of wrong end-to-end network configuration or cabling.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check OC3/STM-1/STM-1J network configuration and cabling and take the


appropriate action.

...................................................................................................................................................................................................................................
15-576 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_pathTraceMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-577
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_signalDegraded_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_signalDegraded_L
alarm.

Description
The STM1/OC3 signal on the line is degraded due to bit error rate greater than 1 per
million.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Poor link quality on the STM1/OC3 line..

System impact
Communication to the RNC may be affected..

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action

...................................................................................................................................................................................................................................
15-578 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_signalDegraded_L
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-579
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_signalDegraded_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_signalDegraded_P
alarm.

Description
The STM1/OC3 signal on the line is degraded due to bit error rate greater than 1 per
million.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Poor link quality on the STM1/OC3 path..

System impact
Communication to the RNC may be affected..

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-580 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_signalDegraded_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-581
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_signalFailed_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_signalFailed_L
alarm.

Description
The STM1/OC3 signal on the line has failed due to bit error rate greater than 1 per
thousand.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Poor link quality on the STM1/OC3 line.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-582 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_signalFailed_L
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-583
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

STM1OC3Port_signalFailed_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the STM1OC3Port_signalFailed_P
alarm.

Description
The STM1/OC3 signal on the path has failed due to bit error rate greater than 1 per
thousand.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Poor link quality on the STM1/OC3 path.

System impact
Communication to the RNC is affected.
In case of a severe fault condition the operational state is set to disabled and the line is
taken out of service.
It may take several minutes to clear the alarm, after the fault condition has been
cleared.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the STM1/OC3 link and take the appropriate action.

...................................................................................................................................................................................................................................
15-584 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance STM1OC3Port_signalFailed_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-585
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Test and Diagnostic Unit
(TDU).

Contents

TDU_applicationInsane 15-587
TDU_boardGenericMismatch 15-589
TDU_communicationFailure 15-591
TDU_configurationMismatch 15-593
TDU_criticalVoltageFailure 15-595
TDU_filterPanelRecordInvalid 15-597
TDU_frequencySynthesizerFailure 15-599
TDU_heaterFailure 15-601
TDU_hwErrorDetectedByPlatformSw 15-603
TDU_initialisationFailure 15-605
TDU_localConfigurationFailure 15-607
TDU_lossOfPulse 15-609
TDU_majorPlatformSwError 15-612
TDU_messageThrottleOn 15-614
TDU_portMapInvalid 15-616
TDU_selfTestFailure 15-618
TDU_temperatureOutOfRange 15-620
TDU_tssiDetectorFailure 15-622

...................................................................................................................................................................................................................................
15-586 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_applicationInsane
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_applicationInsane alarm.

Description
The application software executing on the Test and Diagnostic Unit (TDU) is not
functioning properly.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Software program error.

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-587
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_applicationInsane
procedures

...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-588 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_boardGenericMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_boardGenericMismatch alarm.

Description
The software version on the Test and Diagnostic Unit (TDU) does not match with the
current version stored on the URC, because a software download failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The software on the TDU could not be updated, because the download from the URC
to the TDU failed.

System impact
The TDU can not be initiated to service. No RF antenna tests and diagnostic functions
are available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, fallback to previous NodeB software if appropriate.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TDU object to update the software on the TDU.
If the alarm is cleared, the procedure is completed

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-589
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_boardGenericMismatch
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, check the state of the current NodeB software version via RMT. If
the state is not GOOD, reset the NodeB object.
If the alarm is cleared, the procedure is completed.
Result: The NodeB automatically downloads missing/corrupted software files from
the FTP server (OMC) and updates the software on the TDU.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

5 At the Node B, replace the TDU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-590 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_communicationFailure alarm.

Description
Heartbeat synchronization between the Test and Diagnostic Unit (TDU) and the
Universal Radio Controller (URC) has been lost or timeout occured during
initialization of the TDU.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.
• Backplane EEPROM not accessible

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-591
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_communicationFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed. If the alarm is not
cleared within 5 minutes, the initialization has failed.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the TDU is mounted properly in the frame.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

5 At the Node B, replace the TDU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-592 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-593
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-594 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_criticalVoltageFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_criticalVoltageFailure alarm.

Description
This error condition effects an internally generated DC voltage. The Test and
Diagnostic Unit (TDU) can detect the voltage of the 9.1V converter and raises an
alarm if it is too low or high. There is also a 3.3V converter in series with the 9.1V
converter so if the voltage drops too much, then the system will lose the 3.3V
converter.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The voltage regulator on the TDU is broken.

System impact
The call capacity of the Node B is reduced.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-595
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_criticalVoltageFailure
procedures

...................................................................................................................................................................................................

3 At the Node B, replace the TDU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-596 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_filterPanelRecordInvalid
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_filterPanelRecordInvalid alarm.

Description
One or all filter panel records used for TDU’s configuration are invalid.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Port map might not match filter panel configuration.
• Filter panel might be not connected.
• Local filter panel EEPROM data corrupt.

System impact
TDU cannot be configured properly. The Node B’s Radios will reduce their power, i.e.
the overall traffic capacity is reduced.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-597
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_filterPanelRecordInvalid
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, use the remote RMT to make sure that the backplane EEPROM
data is OK.
...................................................................................................................................................................................................

3 At the OMC-UPS, clear any Filter panel alarms.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the Node B, make sure that all filter panels are mounted correctly.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-598 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_frequencySynthesizerFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_frequencySynthesizerFailure
alarm.

Description
The Test and Diagnostic Unit (TDU) cannot perform an RF measurement.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-599
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_frequencySynthesizerFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for clock alarms of the CTU and OM and perform fault
clearance procedures for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

4 At the Node B, replace the TDU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-600 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_heaterFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_heaterFailure alarm.

Description
The TDU’s own heater failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure on TDU.

System impact
The TDU is unable to deliver correct measurements. The Node B’s Radios will reduce
their power. As a result of this power reduction the overall traffic capacity is reduced.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

3 At the Node B, replace the TDU.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-601
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_heaterFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-602 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_hwErrorDetectedByPlatformSw
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_hwErrorDetectedByPlatformSw
alarm.

Description
The platform code (USL) that supports the application software has detected a
potentially unrecoverable hardware fault.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure.

System impact
The Node B’s Radios will reduce their power. As a result of the power reduction the
overall traffic capacity is reduced.

Automatic corrective actions


The TDU performs a reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TDU object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-603
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_hwErrorDetectedByPlatformSw
procedures

...................................................................................................................................................................................................

3 At the Node B, replace the TDU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-604 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_initialisationFailure alarm.

Description
The Test and Diagnostic Unit (TDU) failed to initialize.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


The TDU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the TDU is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-605
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_initialisationFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

4 At the Node B, replace the TDU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-606 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-607
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_localConfigurationFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-608 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TDU_lossOfPulse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_lossOfPulse alarm.

Description
The Test and Diagnostic Unit (TDU) failed to detect the 10 millisecond pulse.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Probable root causes are:
• Hardware failure
• Timing problem.

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-609
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TDU_lossOfPulse
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for clock alarms of the CTU and OM and perform fault
clearance procedures for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, make sure that the clock cable between the CTU and the TDU is
properly connected.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

6 At the Node B, replace the TDU.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 At the OMC-UPS, lock the CTU object.


...................................................................................................................................................................................................

10 At the Node B, replace the CTU.


...................................................................................................................................................................................................

11 At the OMC-UPS, reset the CTU object.


...................................................................................................................................................................................................

12 At the OMC-UPS, unlock the CTU object.


If the alarm is cleared, the procedure is completed.

....................................................................................................................................................................................................................................
15-610 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_lossOfPulse
procedures

...................................................................................................................................................................................................

13 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-611
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_majorPlatformSwError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_majorPlatformSwError alarm.

Description
The platform code (USL) which supports the application software has reported a major
error.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The boards platform SW detected an error condition which can only be cleared by an
restart of the application software.

System impact
The Radios will reduce their power, i.e. the overall traffic capacity is reduced.

Automatic corrective actions


The TDU performs a reset and the application software gets restarted autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-612 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_majorPlatformSwError
procedures

...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support for more in-depth investigation of this fault.
END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-613
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_messageThrottleOn
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_messageThrottleOn alarm.

Description
The Test and Diagnostic Unit (TDU) reports too many errors to the RCS.

Default severity
Critical

Alarm type
qualityofServiceAlarm

Root cause
System resources overload.

System impact
If too many errors occur in a given time frame, then the TDU will be reset and
reinitialized.
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-614 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_messageThrottleOn
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for other TDU alarms and perform fault clearance procedures
for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

4 At the Node B, replace the TDU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-615
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_portMapInvalid
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_portMapInvalid alarm.

Description
The Test and Diagnostic Unit (TDU) port map contained in the backplane’s EEPROM
is invalid.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The port map contained in the backplane EEPROM is invalid.

System impact
TDU cannot be configured properly. The Radios will reduce their power, i.e. the
overall traffic capacity is reduced.

Automatic corrective actions


THe TDU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, use the remote RMT to make sure that the backplane EEPROM
data is OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-616 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_portMapInvalid
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-617
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_selfTestFailure alarm.

Description
The Test and Diagnostic Unit (TDU) has failed the Board Level Self Test (BLST).

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The system impact will be:
• Reduction of radio power and traffic capacity.
• Unavailability of RF Antenna tests.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the TDU is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TDU object to initialize the TDU.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-618 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_selfTestFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

4 At the Node B, replace the TDU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-619
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_temperatureOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_temperatureOutOfRange alarm.

Description
The TDU temperature sensor has detected a temperature above its design threshold.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible root causes are:
• Heat management failure
• Fan failure.

System impact
Measurement results might be incorrect.

Automatic corrective actions


• The TDU is taken out of service.
• The TDU is isolated, if the number of alarm occurences per hour reach a preset
threshold

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Frame, AmpShelfFan and DigitalShelfFan alarms related
to heat management system or fan problems, and perform the fault clearance procedure
for these alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-620 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_temperatureOutOfRange
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TDU object, if the overTemperature alarm has been
reported several times and so the TDU has been isolated.
the alarm has been cleared and is not reported again, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-621
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TDU_tssiDetectorFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TDU_tssiDetectorFailure alarm.

Description
The Transmit Signal Strength Indicator (TSSI) detector reading is below the maximum
quiet level.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The TSSI detector circuitry on the TDU is broken.

System impact
The Call capacity of the Node B is reduced.

Automatic corrective actions


The TDU is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the TDU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TDU object.


...................................................................................................................................................................................................

3 At the Node B, replace the TDU.


...................................................................................................................................................................................................................................
15-622 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance TDU_tssiDetectorFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TDU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TDU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-623
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

TxAmp alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the amplifier module.

Contents

TxAmp_amplifierSwitchFailure 15-625
TxAmp_communicationFailure 15-627
TxAmp_configurationMismatch 15-629
TxAmp_equipmentFault 15-631
TxAmp_externalAmplifierFailure 15-633
TxAmp_hardwareModelMismatch 15-635
TxAmp_incompletePredistortionCoefficients 15-637
TxAmp_initialisationFailure 15-639
TxAmp_localConfigurationFailure 15-641
TxAmp_messageThrottleOn 15-643
TxAmp_missingPredistortionCoefficients 15-645
TxAmp_overTemperature 15-647
TxAmp_rFOverdrive 15-649
TxAmp_selfTestFailure 15-651
TxAmp_severeExternalAmplifierFailure 15-653
TxAmp_underTemperature 15-655
TxAmp_warmupFailure 15-657

...................................................................................................................................................................................................................................
15-624 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_amplifierSwitchFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_amplifierSwitchFailure
alarm.

Description
The activation/deactivation of the amplifier has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in this cell are lost.

Automatic corrective actions


The Amplifier will be reset.and initialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the Amplifier module reinitialization has been completed.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-625
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_amplifierSwitchFailure
procedures

At the Node B, replace the Amplifier module.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TxAmp object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-626 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_communicationFailure
alarm.

Description
Heartbeat synchronisation between the TxAmp and the URC has been lost or timeout
occured during initialisation of the TxAmp.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.

System impact
All calls in the cell are lost, when a TxAmp fails and performs a reset or when a
TxAmp cannot be initialized to service.

Automatic corrective actions


The amplifier module resets and initializes.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the amplifier module reinitialization is completed. If the
alarm is not cleared within 5 minutes, the initialisation has failed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-627
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_communicationFailure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the OMC-UPS, check for other TxAmp alarms and perform fault clearance
procedure for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the Node B, make sure that the amplifier module is mounted firmly in the shelf and
that the cabling is OK.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object to initialize the amplifier module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

6 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

7 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-628 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_configurationMismatch
alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-629
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-630 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_equipmentFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_equipmentFault alarm.

Description
The amplifier module has detected an equipment failure.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in the cell are lost, when a TxAmp fails and performs a reset or when a
TxAmp cannot be initialized to service.

Automatic corrective actions


The amplifier module resets and initializes.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the amplifier module reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-631
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_equipmentFault
procedures

At the Node B, replace the amplifier module.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-632 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_externalAmplifierFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_externalAmplifierFailure
alarm.

Description
A minor failure of the external amplifier (MCPA or RFoF) has been reported via an
external alarm.
This alarm is raised, if an external amplifier raises an alarm via the external alarm box
of the IOU, where the externalAlarms attribute has been configured as follows for the
specific port: ″specificProblem″ equal to ″failureOnMCPA<i> or
“failureOnExtAmplifier<i>”
Note: i is the instance of the TxAmp object modelling the MCPA or RFoF); ″severity″
equal to major or critical.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Call-processing is blocked and so all calls in this cell are dropped.

Automatic corrective actions


This cell is isolated.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-633
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_externalAmplifierFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the external amplifier is working properly.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-634 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_hardwareModelMismatch
alarm.

Description
The detected hardware model does not match the value specified.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedTxAmpHardware- Go to step 2.
Model is incorrect,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-635
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_hardwareModelMismatch
procedures

If ... then ...


an install of the correct hardware model is Go to step 7.
required,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TxAmp object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

7 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

8 At the Node B, replace the amplified module.


...................................................................................................................................................................................................

9 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the TxAmp object.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-636 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_incompletePredistortionCoefficients
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_incompletePredistortion-
Coefficients alarm.

Description
The predistortion coefficients stored in the amplifier module are incomplete and do not
support the requested maximum cell power.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Missing predistortion data in the EEPROM of amplifier module for the requested
maximum cell power.
• The configured power for the cell is higher than the transmit power amplifier is
calibrated for.

System impact
The system impacts are:
• The Radio cannot be configured properly.
• The cell supported by this Radio cannot be brought to service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-637
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_incompletePredistortionCoefficients
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check whether the maxTransmissionPower attribute (LCell object),


maxDlPowCapability attribute (Cell object) and the txAmpPowerCapability (TxAmp)
for this cell are configured correctly.

If... then...
the attribute values are not go to step 2.
correct,
the attribute values are correct, go to step 4.

...................................................................................................................................................................................................

2 At the OMC-UPS, remove the UtranCell object.


...................................................................................................................................................................................................

3 At the OMC-UPS, re-create (add) the UtranCell with the correct attributes.
If the alarm is cleared the procedure is completed.
...................................................................................................................................................................................................

4 Important! Performing this procedure has service impact on the Node B.


At the Node B, perform the “Amplifier predistortion training” procedure to make sure
that the amplifier module predistortion coefficients are correct.
Result: Refer to the Lucent UMTS Node B Operations, Administration and
Maintenance manual for more information about the “Amplifier predistortion
training” procedure.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-638 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_initialisationFailure alarm.

Description
The amplifier module failed to initialize.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
The amplifier module cannot be initialized to service. All calls in the cell are lost,
when a TxAmp fails and performs a reset or when a TxAmp cannot be initialized to
service.

Automatic corrective actions


The amplifier is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the amplifier module is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TxAmp object to initialize the amplifier module.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-639
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_initialisationFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-640 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-641
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_localConfigurationFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-642 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_messageThrottleOn
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_messageThrottleOn alarm.

Description
Message throttling has been activated because too many errors are being sent by the
amplifier module.

Default severity
Warning

Alarm type
qualityofServiceAlarm

Root cause
System resources at or nearing capacity overload.

System impact
All calls in the cell are lost, when a TxAmp fails and performs a reset or when a
TxAmp cannot be initialized to service.

Automatic corrective actions


The amplifier module is reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for other TxAmp alarms and perform fault clearance
procedures for the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TxAmp object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-643
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_messageThrottleOn
procedures

...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-644 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_missingPredistortionCoefficients
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_missingPredistortionCo-
efficients alarm.

Description
The predistortion coefficient record can not be read from the transmit power amplifier.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• No predistortion training is performed after replacing amplifier module or Radio
hardware failure
• Amplifier module predistortion coefficients are missing or corrupted.

System impact
The system impacts are:
• Reduced transmit power on the cell
• Reduced traffic capacity on the cell.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Important! Performing this procedure has service impact on the Node B.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-645
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_missingPredistortionCoefficients
procedures

At the Node B, perform the “Amplifier predistortion training” procedure to make sure
that the amplifier module predistortion coefficients are correct.
Result: Refer to the Lucent UMTS Node B Operations, Administration and
Maintenance manual for more information about the “Amplifier predistortion
training” procedure.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-646 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_overTemperature alarm.

Description
The amplifier module temperature sensor detected a temperature above the specified
limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Temperature is unacceptable.

System impact
Call processing is blocked on the cell. The amplifier module is shut down (no RF
output) and all calls are lost.

Automatic corrective actions


The amplifier module is isolated if the number of alarm occurences per hour reach a
preset threshold.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for fan (AmpShelfFan or DigitalShelfFan) alarms and


perform the fault clearance procedures for those alarms
If the alarm is cleared together with the fan alarms, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, make sure that the fans are working.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-647
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_overTemperature
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the Node B, make sure that the system is operating within its operational
temperature.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object, if the overTemperature alarm has been
reported several times and so the amplifier module has been isolated.
If the alarm has been cleared and is not reported again, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

6 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

7 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-648 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_rFOverdrive
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_rFOverdrive alarm.

Description
The amplifier module has detected an RF overdrive condition.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Excessive transmitter output power
• Incorrect Radio calibration
• Radio hardware failure.

System impact
The input signal will be limited to prevent damage.
In case of a intermittent fault condition, the alarm is only cleared if the fault did not
occur again within 30 minutes.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Radio alarms and perform fault clearance procedure for
the alarms.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-649
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_rFOverdrive
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 At the Node B, verify that the calibration of the Radio is correct.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, lock the Radio object.


...................................................................................................................................................................................................

8 Important! Replacement has service impact on the Node B.


At the Node B, replace the Radio.
...................................................................................................................................................................................................

9 At the OMC-UPS, reset the Radio object.


...................................................................................................................................................................................................

10 At the OMC-UPS, unlock the Radio object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-650 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_selfTestFailure alarm.

Description
The amplifier module has failed the Board Level Self Test (BLST).

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All calls in the cell are lost, when a TxAmp fails and performs a reset or when a
TxAmp cannot be initialized to service.

Automatic corrective actions


The amplifier is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the amplifier module is mounted correctly in the frame.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the TxAmp object to initialize the amplifier module.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-651
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_selfTestFailure
procedures

...................................................................................................................................................................................................

4 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-652 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_severeExternalAmplifierFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_severeExternalAmplifier-
Failure alarm.

Description
A critical failure of the external amplifier (MCPA or RFoF) has been reported via an
external alarm.
This alarm is raised, if an external amplifier raises an alarm via the external alarm box
of the IOU, where the externalAlarms attribute has been configured as follows for the
specific port: ″specificProblem″ equal to ″failureOnMCPA<i> or
“failureOnExtAmplifier<i>”
Note: i is the instance of the TxAmp object modelling the MCPA or RFoF); ″severity″
equal to major or critical.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
Call-processing is blocked and so all calls in this cell are dropped.

Automatic corrective actions


This cell is isolated.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-653
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_severeExternalAmplifierFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the external amplifier is working properly.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-654 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_underTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_underTemperature alarm.

Description
The amplifier module is operating below its normal operating temperature (warm-up).

Default severity
Warning

Alarm type
environmentalAlarm

Root cause
Amplifier module has not reach proper operating temperature. The amplifier module
has not warmed up sufficiently after DC power is first supplied. The amplifier module
can take up to 15 minutes to warm up.

System impact
Call processing is blocked on the cell.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No immediate action is required. Allow sufficient warm-up time (up to 15 minutes).


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for heat management alarms and perform fault clearance
procedures for the alarms.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-655
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_underTemperature
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-656 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

TxAmp_warmupFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the TxAmp_warmupFailure alarm.

Description
The amplifier module failed to warm up within 15 minutes.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment malfunction.

System impact
All calls in the cell are lost, when a TxAmp fails and performs a reset or when a
TxAmp cannot be initialized to service.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS check:

If... Then...
This is the only TxAmp object Go to step 2.
that is affected,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-657
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance TxAmp_warmupFailure
procedures

If... Then...
There are more TxAmp objects Go to step 7.
affected,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the TxAmp object.


...................................................................................................................................................................................................

3 Important! Replacement has service impact on the Node B.


At the Node B, replace the amplifier module.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the TxAmp object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the TxAmp object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

7 At the OMC-UPS, clear any heat management alarms.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the Node B, make sure that the environment conditions are OK.
...................................................................................................................................................................................................

9 At the OMC-UPS, reset the TxAmp object to initialize the amplifier module.
...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-658 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the UTRA Channel Unit
(UCU).

Contents

UCU_applicationInsane 15-660
UCU_clockFailure30_72Mhz 15-662
UCU_combinerToASICBusFailure 15-664
UCU_communicationFailure 15-666
UCU_configurationMismatch 15-668
UCU_criticalChannelElementFailure 15-670
UCU_criticalChannelElementSystemResourceFailure 15-672
UCU_excessiveDownlinkParityErrors 15-674
UCU_excessiveUplinkParityErrors 15-676
UCU_fPGAFailure 15-678
UCU_hwErrorDetectedByPlatformSw 15-681
UCU_initialisationFailure 15-683
UCU_lossOfForwardBusLink 15-685
UCU_majorChannelElementSystemResourceFailure 15-687
UCU_majorPlatformSwError 15-689
UCU_selfTestFailure 15-691
UCU_voltageOutOfRange 15-693
UCU_watchdogInitiatedReset 15-695

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-659
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_applicationInsane
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_applicationInsane alarm.

Description
The UCU application software is not functioning properly.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Software program error.

System impact
No call processing on this UCU is possible. The system capacity is temporarily
degraded.

Automatic corrective actions


The UCU will be reset, reinitialized autonomously and all calls will be dropped.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-660 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_applicationInsane
procedures

...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-661
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_clockFailure30_72Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_clockFailure30_72Mhz alarm.

Description
The 30.72 MHz clock signal from the CTU has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

3 At the Node B, replace the UCU.

...................................................................................................................................................................................................................................
15-662 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_clockFailure30_72Mhz
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, make sure that the clock distribution within the Node B is OK.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-663
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_combinerToASICBusFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_combinerToASICBusFailure
alarm.

Description
UCU has detected a high parity error rate on the internal ASIC to the combiner bus.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
All channels of the UCU are not available. No call processing on this UCU is possible.
The system capacity is degraded.

Automatic corrective actions


The system performs a UCU reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the clock and power supply of the UCU are OK.

...................................................................................................................................................................................................................................
15-664 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_combinerToASICBusFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

4 At the Node B, replace the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-665
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_communicationFailure alarm.

Description
Heartbeat synchronization between the UTRA Channel Unit (UCU) and the Universal
Radio Controller (URC) has been lost or timeout occured during initialisation of the
UCU.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible root causes are:
• Equipment failure
• Timing problem.
• Missing or pulled board.

System impact
Call processing on this UCU is interrupted. The system capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed. If the alarm is not
cleared within 5 minutes, the initialisation has failed.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-666 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_communicationFailure
procedures

...................................................................................................................................................................................................

2 At the Node B, ensure that the UCU is mounted properly.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

5 At the Node B, replace the UCU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-667
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_configurationMismatch alarm.

Description
UCU mixed configuration (UCU-II and UCU-III) is not supported.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
UCU mixed configuration

System impact
No service available

Automatic corrective actions


The UCU will be isolated

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check if the intended UCU type provides service.


If this is not the case goto Step 2, otherwise goto Step 4.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object(s) which should not provide service.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the alarmed UCU object to bring this UCU back to service.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
15-668 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_configurationMismatch
procedures

...................................................................................................................................................................................................

4 Check, if the UCU needs to be replaced by a UCU of the other type or if the UCU
needs to be removed. In case of replacement
In case of replacement goto Step 5, otherwise goto Step 9.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

6 At the NodeB, replace the UCU board.


...................................................................................................................................................................................................

7 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 At the OMC-UPS, remove the UCU object.


...................................................................................................................................................................................................

10 At the NodeB, remove the UCU board.


...................................................................................................................................................................................................

11 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-669
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_criticalChannelElementFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_criticalChannelElementFailure
alarm.

Description
A critical channel element failure has occured.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Critical equipment failure of one or more channel elements.

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

3 At the Node B, replace the UCU.


...................................................................................................................................................................................................................................
15-670 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_criticalChannelElementFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-671
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_criticalChannelElementSystemResourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_criticalChannelElementSys-
temResourceFailure alarm.

Description
All channel elements on the UCU have failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure of all channel elements

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

3 At the Node B, replace the UCU.


...................................................................................................................................................................................................................................
15-672 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_criticalChannelElementSystemResourceFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-673
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_excessiveDownlinkParityErrors
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_excessiveDownlinkParityErrors
alarm.

Description
The UTRA Channel Unit (UCU) causes a parity error on the transmit bus to the Radio.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Hardware failure on UCU
• Hardware failure on Radio
• Connection problem to backplane.

System impact
The overall traffic capacity of the Node B is reduced.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-674 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_excessiveDownlinkParityErrors
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for clock alarms and take appropriate action.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

4 At the Node B, replace the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the Node B, make sure that the backplane and UCU backplane connector are OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the OMC-UPS, reset the UCU object to initialize the UCU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-675
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_excessiveUplinkParityErrors
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_excessiveUplinkParityErrors
alarm.

Description
The UCU has detected that the uplink data stream on the reverse traffic bus exhibits
excessive parity error rates. This bus is part of the backplane.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Transmit failure
• Failure on transmitting Radio

System impact
All uplink channels of the UCU are unavailable. No call processing on this UCU is
possible. The system capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-676 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_excessiveUplinkParityErrors
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for Radio alarms and perform fault clearance procedures for
the alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, check for power supply and clock reports and take the appropriate
action.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

5 At the Node B, replace the UCU.


...................................................................................................................................................................................................

6 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

8 At the Node B, make sure that the backplane bus is working properly.
...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-677
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

UCU_fPGAFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_fPGAFailure alarm.

Description
The UCU has detected a faulty Field Programmable Gate Array (FPGA) behavior
during reset, load or start of the FPGA.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
This could be a FPGA hardware problem or a problem with the loadable FPGA image.

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


UCU performs a reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
15-678 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance UCU_fPGAFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the following:

If... Then...
This is the only UCU that is Go to step 2.
reporting an alarm,
There are more UCUs reporting Go to step 8.
an alarm,

...................................................................................................................................................................................................

3 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

4 At the Node B, replace the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

8 If ... Then ...


The alarm was generated during activation • Trigger a fallback command to
of new Node B software, fallback to a previous Node B
software
• Contact Alcatel-Lucent customer
support.
The alarm was generated during other Reset the Node B, so the Node B retrieves
activities, missing or corrupted files from the FTP
server and re-initializes the UCU.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-679
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_fPGAFailure
procedures

...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-680 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_hwErrorDetectedByPlatformSw
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_hwErrorDetectedByPlat-
formSw alarm.

Description
The platform code (USL) that supports the application software has detected a
potentially unrecoverable hardware fault.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure

System impact
Calls served by this UCU are dropped. The traffic capacity of the Node Bs is
temporarily degraded.

Automatic corrective actions


The UCU performs a reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-681
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_hwErrorDetectedByPlatformSw
procedures

...................................................................................................................................................................................................

3 At the Node B, replace the UCU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-682 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_initialisationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_initialisationFailure alarm.

Description
The UTRA Channel Unit (UCU) failed to initialize due to a Board Level Self Test
(BLST), Reset, or Enable Failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


The UCU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the UCU is mounted correctly.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the UCU object to initialize the UCU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-683
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_initialisationFailure
procedures

...................................................................................................................................................................................................

4 At the Node B, replace the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-684 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_lossOfForwardBusLink
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_lossOfForwardBusLink alarm.

Description
The UTRA Channel Unit (UCU) causes a link loss on the transmit bus to the Radio.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Hardware failure on UCU
• Hardware failure on Radio
• Connection problem to backplane.

System impact
Overall Node B’s traffic capacity is reduced.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-685
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_lossOfForwardBusLink
procedures

...................................................................................................................................................................................................

3 At the Node B, replace the UCU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the Node B, make sure that the backplane and UCU backplane connector are OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 At the OMC-UPS, reset the UCU object to initialize the UCU.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-686 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_majorChannelElementSystemResourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_majorChannelElementSys-
temResourceFailure alarm.

Description
At least one, but not all channel elements have failed on the UCU board.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
channel element failure.

System impact
The capacity of the UCU is degraded.
Service Interruption on failed channel elements.

Automatic corrective actions


UCU software autonomously reinitializes failed channel elements.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for CTU and OM (if present) alarms and perform the fault
clearance procedure for these alarms.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 UCU replacement is recommended.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-687
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_majorChannelElementSystemResourceFailure
procedures

At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

3 At the NodeB, replace the UCU.


...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-688 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_majorPlatformSwError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_majorPlatformSwError alarm.

Description
The platform code (USL) that supports the application software has reported a major
error.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The UCU platform SW detected an error condition that can only be cleared by a restart
of the application software.

System impact
Calls served by this UCU are dropped. The Node B’s traffic capacity is temporarily
degraded.

Automatic corrective actions


The UCU performs a reset. The application software gets restarted autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-689
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_majorPlatformSwError
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-690 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_selfTestFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_selfTestFailure alarm.

Description
The UTRA Channel Unit (UCU) Board Level Self Test (BLST) failed. The BLST is
stored in the Info RAM and can be read.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
No call processing on this UCU is possible. The system capacity is degraded.

Automatic corrective actions


The UCU is isolated.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the card is mounted correctly.


...................................................................................................................................................................................................

2 At the OMC-UPS, reset the UCU object to initialize the UCU.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-691
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_selfTestFailure
procedures

...................................................................................................................................................................................................

4 At the Node B, replace the UCU.


...................................................................................................................................................................................................

5 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-692 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_voltageOutOfRange
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_voltageOutOfRange alarm.

Description
The internal voltage provided by the on board power supply is out of range.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment failure.

System impact
No call processing on this UCU is possible. System capacity is degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the alarms of other UCUs.


If alarms are reported for other UCUs, there is a general problem with the power
supply; goto 3, otherwise goto step 5.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-693
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_voltageOutOfRange
procedures

...................................................................................................................................................................................................

3 At the Node B, check and repair the power supply for the UCU boards
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object to initialize the UCU board.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the Node B, check the power supply at the board slot for further indications and
take the appropriate action.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

7 At the Node B, replace the UCU.


...................................................................................................................................................................................................

8 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-694 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

UCU_watchdogInitiatedReset
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the UCU_watchdogInitiatedReset alarm.

Description
The UTRA Channel Unit (UCU) watchdog process has reset the UCU.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Timing problem.

System impact
Call capacity is temporarily degraded.

Automatic corrective actions


The UCU will be reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the UCU reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the UCU object.


...................................................................................................................................................................................................

3 At the Node B, replace the UCU.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-695
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance UCU_watchdogInitiatedReset
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, reset the UCU object.


...................................................................................................................................................................................................

5 At the OMC-UPS, unlock the UCU object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-696 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Universal Radio Controller
(URC).

Contents

URC_aTMOutOfCellDelineation 15-698
URC_applicationInsane 15-700
URC_clockFailure30_72Mhz 15-701
URC_configurationMismatch 15-703
URC_hardwareModelMismatch 15-705
URC_hwErrorDetectedByPlatformSw 15-707
URC_localConfigurationFailure 15-709
URC_lossOfPulse 15-711
URC_majorPlatformSwError 15-713

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-697
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

URC_aTMOutOfCellDelineation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_aTMOutOfCellDelineation
alarm.

Description
A configuration error has occurred in ATM communication.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Configuration or customizing error.

System impact
Traffic on the whole Node B is impossible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the ATM network configuration between the RNC and the Node B for clock
errors and take the appropriate action.

...................................................................................................................................................................................................................................
15-698 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance URC_aTMOutOfCellDelineation
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-699
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance
procedures

URC_applicationInsane
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_applicationInsane alarm.

Description
Application software executing on the URC is not functioning properly.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Software program error.

System impact
Traffic on the whole Node B is impossible.

Automatic corrective actions


The URC resets and initializes autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
15-700 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_clockFailure30_72Mhz
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_clockFailure30_72Mhz alarm.

Description
The 30.72 MHz clock signal from the CTU has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Calls on the whole Node B are lost.

Automatic corrective actions


The URC performs a reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the URC reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for NodeB_databaseCleared and perform fault clearance


procedure for the alarm.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-701
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_clockFailure30_72Mhz
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, backup the Node B database.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the NodeB object.


...................................................................................................................................................................................................

5 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

6 At the OMC-UPS, restore the Node B database.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the NodeB object.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-702 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_configurationMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_configurationMismatch alarm.

Description
The configuration conflicts with attribute value(s) of other object(s).

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for nodeBTypeMismatch alarm of the NodeB object and perform
the fault clearance procedure for that alarm.
If this alarm is cleared together with the nodeBTypeMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 Contact Alcatel-Lucent customer support to verify the planning data for this Node B
and recreate the Node B with the new data.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-703
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_configurationMismatch
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-704 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_hardwareModelMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_hardwareModelMismatch
alarm.

Description
The detected hardware does not match the value specified.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Inconsistent planning.

System impact
No impact on service.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the planning data.

If ... then ...


the attribute expectedURCHardwareModel Go to step 2.
is incorrect,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-705
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_hardwareModelMismatch
procedures

If ... then ...


an install of the correct hardware model is Go to step 6.
required,

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the URC object.


...................................................................................................................................................................................................

3 At the OMC-UPS, update the expected hardware model attribute to match the detected
hardware model attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the URC object


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

6 At the OMC-UPS, lock the URC object.


...................................................................................................................................................................................................

7 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

8 At the OMC-UPS, reset the URC object.


...................................................................................................................................................................................................

9 At the OMC-UPS, unlock the URC object.


...................................................................................................................................................................................................

10 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-706 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_hwErrorDetectedByPlatformSw
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_hwErrorDetectedByPlat-
formSw alarm.

Description
The platform which supports the application software has detected a potentially
unrecoverable hardware fault.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Hardware failure

System impact
The whole Node B is reset and temporarily unavailable.

Automatic corrective actions


The URC performs a reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the URC reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for NodeB_databaseCleared and perform fault clearance


procedure for the alarm.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-707
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_hwErrorDetectedByPlatformSw
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the OMC-UPS, backup the Node B database.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the NodeB object.


...................................................................................................................................................................................................

5 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

6 At the OMC-UPS, restore the Node B database.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the NodeB object.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-708 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_localConfigurationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_localConfigurationFailure
alarm.

Description
The configuration conflicts with local configuration data.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Missing or faulty local configuration data.

System impact
No service available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, check for configurationMismatch alarm and perform fault clearance
procedure for that alarm..
If the alarm is cleared together with the configurationMismatch alarm, the procedure is
completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check and update local configuration data via remote RMT.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-709
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_localConfigurationFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-710 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_lossOfPulse
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_lossOfPulse alarm.

Description
The URC failed to detect the 10 millisecond pulse.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Timing problem.

System impact
Calls on the whole Node B are lost.

Automatic corrective actions


The URC is reset and reinitialized autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for clock alarms of the CTU and OM and perform fault
clearance procedures for the alarms..
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, reset the NodeB object.


...................................................................................................................................................................................................

3 At the OMC-UPS, lock the URC object.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-711
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_lossOfPulse
procedures

...................................................................................................................................................................................................

4 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the URC object.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the URC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-712 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - Node B alarm clearance
procedures

URC_majorPlatformSwError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the URC_majorPlatformSwError alarm.

Description
The platform code (USL) that supports the application software has reported a major
error.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The URC platform software detected an error condition that can only be cleared by a
restart of the application software.

System impact
The whole Node B is reset and temporarily unavailable.

Automatic corrective actions


The URC performs a reset. The application software is restarted autonomously.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, wait until the URC reinitialization is completed.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, check for NodeB_databaseCleared and perform fault clearance


procedure for the alarm.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 15-713
Issue 1, August 2007 See notice on first page
Corrective maintenance - Node B alarm clearance URC_majorPlatformSwError
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the OMC-UPS, backup the Node B database.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the NodeB object.


...................................................................................................................................................................................................

5 At the Node B, replace the URC.


For a detailed replacement procedure, refer to the UMTS Node B Operation,
Administration and Maintenance manual associated with this Node B type.
...................................................................................................................................................................................................

6 At the OMC-UPS, restore the Node B database.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the NodeB object.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
15-714 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
16 16
Corrective maintenance - RNC
alarm clearance procedures

Overview
...................................................................................................................................................................................................................................

Purpose
This chapter provides procedures to clear RNC alarms that are raised on the OMC.

Related information
For more related information about this topic, refer to:
• Radio Network Controller Operations, Administration and Maintenance RNC
OA&M, 401-382-360

Contents

General information 16-14


RNC fault recovery actions 16-15
Autonomous recovery actions taken by the RNC 16-18
RNC hardware replacement procedures 16-19
AC alarms 16-20
AC_communicationFailure 16-21
AC_softwareVersionMismatch 16-23
CICC alarms 16-24
CICC_degradeGroupMemberFault 16-25
CICC_escalatingRecovery 16-27
CICC_failureGroupMemberFault 16-29
CICC_lossOfPower 16-31
CICC_lossOfSanity 16-33
CICC_lostCommunication 16-35

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-1
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

CICC_maintenanceMode 16-37
CICC_notInstalled 16-38
CICC_overTemperature 16-40
CICC_overTemperatureInFlow 16-42
CICC_overTemperatureOutFlow 16-44
CICCBPEtherPort alarms 16-46
CICCBPEtherPort_communicationFailureESC1_2 16-47
CICCBPEtherPort_communicationFailureESC1_21 16-49
CICCBPEtherPort_communicationFailureESC2_2 16-51
CICCBPEtherPort_communicationFailureESC2_21 16-53
CICCBPEtherPort_linkFailure 16-55
CICCBPEtherPort_restoreServiceFailure 16-57
CICCProc alarms 16-59
CICCProc_communicationFailure 16-60
CICCProc_communicationFailureLRM 16-62
CICCProc_configurationError 16-64
CICCProc_cpuUsageOverload 16-65
CICCProc_criticalSoftwareFailure 16-66
CICCProc_heartbeatFailure 16-68
CICCProc_memoryBlockError 16-70
CICCProc_memoryUsageOverload 16-72
CICCProc_resourceFailure 16-73
CICCProc_restoreServiceFailure 16-75
CICCProc_softwareAssertError 16-77
CICCProc_softwareVersionMismatch 16-79
CICCProc_standbyMateDown 16-81
CICCProc_switchover 16-83
CICCProc_vitalResourceFailure 16-85
Cabinet alarms 16-87
Cabinet_fanOrCktBreakerFailure 16-88
EDCH alarms 16-89
EDCH_configurationRequestFailed 16-90

...................................................................................................................................................................................................................................
16-2 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

EDCH_resourceDegradation 16-92
EDCH_resourceFailure 16-94
ESC alarms 16-96
ESC_degradeGroupMemberFault 16-97
ESC_failureGroupMemberFault 16-99
ESC_lossOfPower 16-101
ESC_lossOfSanity 16-103
ESC_lostCommunication 16-105
ESC_maintenanceMode 16-107
ESC_notInstalled 16-108
ESC_overTemperature 16-110
ESCProc_softwareVersionMismatch 16-112
ESCBPEtherPort alarms 16-114
ESCBPEtherPort_linkFailure 16-115
ESCFAEtherPort alarms 16-117
ESCFAEtherPort_linkFailure 16-118
ESCProc alarms 16-120
ESCProc_communicationFailure 16-121
ExtAlmBox alarms 16-123
ExtAlmBox_communicationFailure 16-125
ExtAlmBox_externalAlarmPort1 16-127
ExtAlmBox_externalAlarmPort10 16-129
ExtAlmBox_externalAlarmPort11 16-131
ExtAlmBox_externalAlarmPort12 16-133
ExtAlmBox_externalAlarmPort13 16-135
ExtAlmBox_externalAlarmPort14 16-137
ExtAlmBox_externalAlarmPort15 16-139
ExtAlmBox_externalAlarmPort16 16-141
ExtAlmBox_externalAlarmPort17 16-143
ExtAlmBox_externalAlarmPort18 16-145
ExtAlmBox_externalAlarmPort19 16-147
ExtAlmBox_externalAlarmPort2 16-149

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-3
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

ExtAlmBox_externalAlarmPort20 16-151
ExtAlmBox_externalAlarmPort21 16-153
ExtAlmBox_externalAlarmPort22 16-155
ExtAlmBox_externalAlarmPort23 16-157
ExtAlmBox_externalAlarmPort24 16-159
ExtAlmBox_externalAlarmPort25 16-161
ExtAlmBox_externalAlarmPort26 16-163
ExtAlmBox_externalAlarmPort27 16-165
ExtAlmBox_externalAlarmPort28 16-167
ExtAlmBox_externalAlarmPort29 16-169
ExtAlmBox_externalAlarmPort3 16-171
ExtAlmBox_externalAlarmPort30 16-173
ExtAlmBox_externalAlarmPort31 16-175
ExtAlmBox_externalAlarmPort32 16-177
ExtAlmBox_externalAlarmPort4 16-179
ExtAlmBox_externalAlarmPort5 16-181
ExtAlmBox_externalAlarmPort6 16-183
ExtAlmBox_externalAlarmPort7 16-185
ExtAlmBox_externalAlarmPort8 16-187
ExtAlmBox_externalAlarmPort9 16-189
FBPShelf alarms 16-191
FBPShelf_overTemperature 16-192
FBPShelf_overTemperatureSensor1 16-194
FBPShelf_overTemperatureSensor2 16-196
FBPShelf_overTemperatureSensor3 16-198
FBPShelf_overTemperatureSensor4 16-200
FBPShelf_overTemperatureSensor5 16-202
FBPShelf_overTemperatureSensor6 16-204
FBPShelf_overTemperatureSensor7 16-206
FBPShelf_overTemperatureSensor8 16-208
FanTray alarms 16-210
FanTray_fan1Failure 16-211

...................................................................................................................................................................................................................................
16-4 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

FanTray_fan2Failure 16-213
FanTray_fan3Failure 16-215
FanTray_notInstalled 16-217
GICC alarms 16-218
GICC_degradeGroupMemberFault 16-219
GICC_escalatingRecovery 16-221
GICC_failureGroupMemberFault 16-223
GICC_lossOfPower 16-225
GICC_lossOfSanity 16-227
GICC_lostCommunication 16-229
GICC_maintenanceMode 16-231
GICC_notInstalled 16-232
GICC_overTemperature 16-234
GICC_overTemperatureInFlow 16-236
GICC_overTemperatureOutFlow 16-238
GICCBPEtherPort alarms 16-240
GICCBPEtherPort_communicationFailureESC1_2 16-241
GICCBPEtherPort_communicationFailureESC1_21 16-243
GICCBPEtherPort_communicationFailureESC2_2 16-245
GICCBPEtherPort_communicationFailureESC2_21 16-247
GICCBPEtherPort_linkFailure 16-249
GICCBPEtherPort_restoreServiceFailure 16-251
GICCFAEtherPort alarms 16-253
GICCFAEtherPort_linkFailure 16-254
GICCFAEtherPort_restoreServiceFailure 16-256
GICCProc alarms 16-258
GICCProc_allOpticalLinksFailed 16-259
GICCProc_communicationFailure 16-261
GICCProc_communicationFailureLRM 16-263
GICCProc_configurationError 16-265
GICCProc_cpuUsageOverload 16-266
GICCProc_criticalSoftwareFailure 16-267

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-5
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

GICCProc_heartbeatFailure 16-269
GICCProc_memoryBlockError 16-271
GICCProc_memoryUsageOverload 16-273
GICCProc_resourceFailure 16-274
GICCProc_restoreServiceFailure 16-276
GICCProc_softwareAssertError 16-278
GICCProc_softwareVersionMismatch 16-280
GICCProc_standbyMateDown 16-282
GICCProc_vitalResourceFailure 16-284
GICCSTM1OC3Port alarms 16-286
GICCSTM1OC3Port_linkFailure 16-287
GICCSTM1OC3Port_linkFailureAIS_L 16-289
GICCSTM1OC3Port_linkFailureAIS_P 16-291
GICCSTM1OC3Port_linkFailureLCD_P 16-293
GICCSTM1OC3Port_linkFailureLOF 16-295
GICCSTM1OC3Port_linkFailureLOP_P 16-297
GICCSTM1OC3Port_linkFailureLOS 16-299
GICCSTM1OC3Port_linkFailurePLM_P 16-301
GICCSTM1OC3Port_linkFailureRDI_L 16-303
GICCSTM1OC3Port_linkFailureRDI_P 16-305
GICCSTM1OC3Port_restoreServiceFailure 16-307
HSDPA alarms 16-309
HSDPA_degraded 16-310
HSDPA_failed 16-312
HSDPA_hSDPAOCNSchannelSetupFailure 16-314
HSDPA_notInstalled 16-316
IuB alarms 16-318
IuB_cellReconfigTimeout 16-319
IuB_cellSetupTimeout 16-321
IuB_channelReconfigFailure 16-323
IuB_channelReconfigTimeout 16-325
IuB_channelSetupFailure 16-327

...................................................................................................................................................................................................................................
16-6 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

IuB_channelSetupTimeout 16-329
IuB_highBER 16-331
IuB_nBAP_Reset_Requ_CCP_Fail 16-333
IuB_nBAP_Reset_Requ_Fail 16-335
IuB_nodeBCommunicationLost 16-337
IuB_parameterFailure 16-340
IuB_resourceFailure 16-342
IuB_sAALUNI_RES_PROT_STA_DN 16-344
IuB_sAALUNI_VCC_ST_DN 16-346
IuB_uNIStack_FAIL 16-348
IuCS alarms 16-350
IuCS_coreNetwork_OOS_For_NonUE_Sig 16-351
IuCS_rANAPResetFail 16-353
IuCS_remoteSubsystemOutOfService 16-355
IuCS_sNE_Context_Cre_Fail_For_NonUE_Sig 16-357
IuPS alarms 16-359
IuPS_coreNetwork_OOS_For_NonUE_Sig 16-360
IuPS_gTP_U_Echo_Responses_Not_Received 16-362
IuPS_rANAPResetFail 16-364
IuPS_remoteSubsystemOutOfService 16-366
IuPS_sNE_Context_Cre_Fail_For_NonUE_Sig 16-368
IuPSSubNet alarms 16-370
IuPSSubNet_communicationFailure 16-371
IuR alarms 16-373
IuR_pRNC_OOS_For_NonUE_Sig 16-374
IuR_remoteSubsystemOutOfService 16-376
IuR_sNE_Context_Cre_Fail_For_NonUE_Sig 16-378
LCell alarms 16-380
LCell_avail_Status_Degraded 16-381
LCell_bCCHScheduleErr 16-382
LCell_callPreemptionError 16-384
LCell_callPreemptionFailure 16-386

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-7
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

LCell_channelSetupFailure 16-388
LCell_code_Allocation_Failure 16-390
LCell_code_Starvation 16-392
LCell_common_Transport_Channel_Reconfiguration_Failure 16-394
LCell_common_Transport_Channel_Reconfiguration_Timeout 16-396
LCell_common_Transport_Channel_Setup_Failure 16-398
LCell_common_Transport_Channel_Setup_Timeout 16-400
LCell_configurationError 16-402
LCell_configurationErrorSCCPCH 16-404
LCell_nodeBUnavailable 16-406
LCell_rRC_Connection_Establish_Failure 16-408
LCell_reconfigFailure 16-410
LCell_reconfigTimeout 16-412
LCell_setupFailure 16-414
LCell_setupTimeout 16-416
LCell_system_Information_Update_Failure 16-418
LCell_tPUCellContextFailure 16-420
LNodeB alarms 16-421
LNodeB_cell_Deletion_No_Response 16-422
LNodeB_cre_Control_End_Pt_Fail 16-424
LNodeB_download_Logical_Cell_Information_To_RNC_Failed 16-425
LRNC alarms 16-427
LRNC_alarmDefFileCorrupt 16-429
LRNC_alarmDefFileMissing 16-431
LRNC_cLIScriptFailed 16-433
LRNC_ciccGiccConfigFileMissing 16-435
LRNC_clockSourceFailure 16-437
LRNC_configurationError 16-438
LRNC_coreFileGenerated 16-440
LRNC_dBReplicationAuditFailure 16-442
LRNC_dGPSCorrFailure 16-445
LRNC_dataAuditFailure 16-447

...................................................................................................................................................................................................................................
16-8 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

LRNC_degradeGroupMemberFault 16-449
LRNC_eventFloodConditionDetected 16-451
LRNC_failureGroupMemberFault 16-453
LRNC_ftProcessError 16-454
LRNC_general_Handling_Error_Indication 16-457
LRNC_hostProcessCommunicationFailure 16-459
LRNC_hostProcessEnlistTimeout 16-461
LRNC_hostProcessFailure 16-463
LRNC_hostProcessRestartFailure 16-464
LRNC_hostProcessRestartSuspended 16-466
LRNC_hostProcessTerminationFailure 16-468
LRNC_iCNOAPVCMeshErr 16-470
LRNC_iNITrunLevelTimeout 16-472
LRNC_iNITterminatingTimeout 16-474
LRNC_internal_Clock_Source_Disconnected 16-476
LRNC_log100PercentFull 16-477
LRNC_log80PercentFull 16-479
LRNC_miscellaneous-Cause 16-481
LRNC_oamStateControlFailure 16-483
LRNC_perfMgr_DNMAP_INIT 16-485
LRNC_pmArchiveInitFailure 16-487
LRNC_pmCTDBImageFailure 16-489
LRNC_pmCTDBInitFailure 16-491
LRNC_primary_Clock_Source_Disconnected 16-493
LRNC_sMLC_UDP_Port_Fail 16-495
LRNC_sRS_NAV_Data_Ind 16-496
LRNC_secondSRSTCPEstLinkFailure 16-498
LRNC_suActivationFailure 16-500
LRNC_suApplyFailure 16-503
LRNC_suBackoutFailure 16-506
LRNC_suCommitFailure 16-510
LRNC_suDeApplyFailure 16-512

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-9
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

LRNC_suDeleteFailure 16-515
LRNC_suDownloadFailure 16-517
LRNC_suFallbackFailure 16-520
LRNC_suICCPartialUpdateFailure 16-523
LRNC_suInfoSyncFailure 16-526
LRNC_suInstallFailure 16-529
LRNC_suStatePanicFailure 16-531
LRNC_ueCompressedModeGapOverlap 16-533
LRNC_utranCompressedModeGapOverlap 16-535
OCNS alarms 16-537
OCNS_chDelRxLock 16-538
OCNS_channelFailure 16-540
OCNS_channelReconfigFailure 16-542
OCNS_channelReestablished 16-544
OCNS_channelSetupFailure 16-546
OCNS_resourcesUnavailable 16-548
OCNSHSDPA alarms 16-550
OCNSHSDPA_failureIndicationFromNodeB 16-551
OCNSHSDPA_setupFailed 16-553
PG alarms 16-555
PG_apsCriticalLineFailure 16-556
PG_apsCriticalProcessorFailure 16-558
PG_apsMajorLineFailure 16-560
PG_apsMajorProcessorFailure 16-562
PG_apsMinorLineFailure 16-564
PG_apsMinorProcessorFailure 16-566
PRACH alarms 16-568
PRACH_op_State_Disabled 16-569
PSU alarms 16-571
PSU_equipmentFailure 16-572
PSU_overTemperature 16-574
RF trace alarms 16-576

...................................................................................................................................................................................................................................
16-10 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

RFTrace_ueMeasurementsUnavailable 16-577
SB alarms 16-579
SB_bscSwFailOutage_CNIWMCapsule1 16-580
SB_bscSwFailOutage_CellServerCapsule1 16-582
SB_bscSwFailOutage_CellServerCapsule10 16-584
SB_bscSwFailOutage_CellServerCapsule2 16-586
SB_bscSwFailOutage_CellServerCapsule3 16-588
SB_bscSwFailOutage_CellServerCapsule4 16-590
SB_bscSwFailOutage_CellServerCapsule5 16-592
SB_bscSwFailOutage_CellServerCapsule6 16-594
SB_bscSwFailOutage_CellServerCapsule7 16-596
SB_bscSwFailOutage_CellServerCapsule8 16-598
SB_bscSwFailOutage_CellServerCapsule9 16-600
SB_bscSwFailOutage_PeerRNCIWMCapsule1 16-602
SB_bscSwFailOutage_RNSServerCapsule1 16-604
SB_degradeGroupMemberFault 16-606
SB_failureGroupMemberFault 16-608
SB_lossOfPower 16-610
SB_lossOfSanity 16-612
SB_lostCommunication 16-614
SB_maintenanceMode 16-616
SB_notInstalled 16-617
SB_overTemperature 16-619
SBBPEtherPort alarms 16-621
SBBPEtherPort_linkFailure 16-622
SBClan alarms 16-623
SBClan_linkFail 16-624
SBProc alarms 16-625
SBProc_acCommunicationFailure 16-627
SBProc_componentMissing 16-628
SBProc_cpuUsageOverload 16-629
SBProc_diskReadTimeExceeded 16-630

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-11
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

SBProc_fLXEV_CLAN_PARENT_FAIL 16-632
SBProc_fLXEV_NODE_FAILING 16-633
SBProc_fLXEV_NODE_NOTACTIVE 16-635
SBProc_fLXEV_SMON_NOHBEAT 16-637
SBProc_filesystem01Full 16-639
SBProc_filesystem02Full 16-640
SBProc_filesystem03Full 16-641
SBProc_filesystem04Full 16-642
SBProc_filesystem05Full 16-643
SBProc_filesystem06Full 16-644
SBProc_filesystem07Full 16-645
SBProc_filesystem08Full 16-646
SBProc_filesystem09Full 16-647
SBProc_filesystem10Full 16-648
SBProc_filesystem11Full 16-649
SBProc_filesystem12Full 16-650
SBProc_filesystem13Full 16-651
SBProc_filesystem14Full 16-652
SBProc_filesystem15Full 16-653
SBProc_filesystem16Full 16-654
SBProc_lossOfClockSourceSync 16-655
SBProc_memoryUsageOverload 16-657
SBProc_nodeFailure 16-659
SBProc_overTemperature 16-661
SBProc_processFailure 16-663
SBProc_processFailureApplication 16-665
SBProc_rootLoginFailure 16-668
SBProc_sULoginFailure 16-669
SBProc_shutdownTempReached 16-670
SBProc_temperatureOffLimits 16-672
SBProc_userLoginFailure 16-674
SBProc_virtualClusterFailure 16-675

...................................................................................................................................................................................................................................
16-12 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance Overview
procedures

SBProc_virtualClusterVirtualMachineFailure 16-676
SCCPCHFach alarms 16-678
SCCPCHFach_op_State_Disabled 16-679
SCCPCHPch alarms 16-681
SCCPCHPch_op_State_Disabled 16-682
SMLC alarms 16-684
SMLC_dGPSCorrectionFailure 16-685
SMLC_primarySRSIpConnectionFailure 16-687
SMLC_primarySRSLinkFailure 16-689
SMLC_sRS-Both-IP-Fail 16-691
SMLC_sRS_SV_Ind 16-693
SMLC_secondarySRSIpConnectionFailure 16-695
SMLC_secondarySRSLinkFailure 16-697
SS7Link alarms 16-699
SS7Link_mtp3LinkDown 16-700
SS7Link_mtp3LinkRemotelyBlocked 16-702
SS7Link_qsaalLinkCongested 16-704
SS7LinkSet alarms 16-706
SS7LinkSet_congestionTowardsRemoteMTP3 16-707
SS7LinkSet_remoteMTP3Unreachable 16-709
SS7LinkSet_remoteMTP3UserUnavailable 16-711
SS7Stack alarms 16-712
SS7Stack_nniStackFailure 16-713

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-13
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

General information

Overview
...................................................................................................................................................................................................................................

Purpose
This section provides general information on how the RNC handles hardware and
software faults.

Contents

RNC fault recovery actions 16-15


Autonomous recovery actions taken by the RNC 16-18
RNC hardware replacement procedures 16-19

...................................................................................................................................................................................................................................
16-14 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

RNC fault recovery actions


...................................................................................................................................................................................................................................

Purpose
This topic describes alarm recovery actions that are taken when a fault occurs in the
RNC hardware or software.

Alarm recovery process flow


The process flow illustrating the fault recovery actions:

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-15
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance RNC fault recovery actions
procedures

Alarm occurs

Report alarm

Autonomous Y
recovery action
performed?

Re-
N
Isolate N initialization N
unit? threshold
reached?
Re-initialize unit
Y Y

Isolate unit

Operator performs
fault clearance procedure

N Fault
cleared?

Is
alarm of N Operator
ADAC clears alarm
Nature?

Automatically
clear alarm

End

Report the alarm


When a fault occurs in an RNC hardware or software unit, the fault is reported to the
Fault Management (FM) software in the RNC.
After receiving this fault indication the FM software reports the appropriate alarm to
the FIMS-UT and/or the OMC.

....................................................................................................................................................................................................................................
16-16 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance RNC fault recovery actions
procedures

Possible alarm recovery actions


If a standby unit is available, a switch-over is performed to this unit to guarantee that
the RNC remains operational.
Depending on the seriousness of the fault and the type of unit on which the fault has
been reported, the FM software can take the following actions when a fault occurs:
• Automatically reinitialize the unit
• Isolate the unit and request for manual intervention.

Automatically reinitialize
If the unit supports an automatic reinitialization, one or more of the following
reinitialization actions can be performed:
• Restart one or more software processes
• Reboot the software
• Reset the complete unit.
Note: If the automatic reinitialization fails, this action is repeated until the
reinitialization threshold has been exceeded. When the threshold is exceeded and the
fault is not corrected, the unit will be isolated.

Isolate unit
If the unit does not support an automatic recovery action, the unit can be put into an
isolated state. When the unit is in this state it cannot be used by any of the other units.

Perform fault clearance procedure


The operator must perform the fault clearance procedures for the unit when:
• The unit does not support an automatic reinitialization
• The fault was not severe enough to reinitialize the unit
• The unit is moved into the isolated state.

Clearing ADAC alarms


When an alarm with a nature of ADAC (Automatically Detected Automatically
Cleared) is solved, an alarm clear message is forwarded to the FIMS-UT and/or the
OMC to remove the alarm from the active alarm list.

Clearing ADMC alarms


When an alarm with a nature of ADMC (Automatically Detected Manual Cleared) is
solved, the alarm remains on the active alarm list on the FIMS-UT and/or the OMC
until the FIMS-UT or OMC operator manually clears the alarm.

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-17
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

Autonomous recovery actions taken by the RNC


...................................................................................................................................................................................................................................

Overview
This topic describes the autonomous actions that are taken by the RNC whenever the
RNC is internally reset.

Autonomous recovery
When a severe fault occurs, the RNC will autonomously reset itself.

RNC status during autonomous recovery


When a RNC is reset, the OMC loses communication with the RNC.
During the reset, the OMC should generate an alarm indicating a loss of
communication, or a heartbeat failure for that RNC. This alarm should exist until the
RNC completes the reset and re-registers with the OMC.

Reasons autonomous recovery


The following list indicates the different events that can cause the RNC to perform an
autonomous recovery action:
• Failing software in the CPSB platform.

Autonomous recovery actions


The following actions are taken after a severe fault has been detected in the URC:

Action Result Expected


recovery time
The RNC will be reset The RNC will not be operational and < 5 min1
using a reset Type 1 capable of performing call processing
functions until it returns to the
operational state. At the moment of
the reset all stable calls will be
dropped.

Notes:
1. If the RNC software restarted successfully.

...................................................................................................................................................................................................................................
16-18 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

RNC hardware replacement procedures


...................................................................................................................................................................................................................................

RNC hardware replacement


If hardware must be replaced, the fault clearance procedure lists the following steps:
1. Lock <object-name>
2. Replace <hardware>
3. Unlock <object-name>.
These fault clearance procedure steps are not intended as an exact step-by-step
procedure, but only as an high level overview.
The exact steps in the procedure to replace hardware are described in “Fault
Management”, chapter “Corrective maintenance - fault correction” of the OAM manual
for the related network element.
The chapter describes the detailed step-by-step procedures and includes additional
information, such as safety warnings and required tools.

Related RNC OAM manuals


For the procedures to replace RNC hardware, refer to:
• Lucent Radio Network Controller Operations, Administration and Maintenance,
401-382-360

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-19
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

AC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Alarm Card alarms.

Contents

AC_communicationFailure 16-21
AC_softwareVersionMismatch 16-23

...................................................................................................................................................................................................................................
16-20 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

AC_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the AC_communicationFailure alarm.

Description
Communication to the Alarm Card (AC) has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
No SNMP communication between the SB and alarm card.

System impact
No blade management functions available.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, if the AC is initializing, ensure that the AC restores successfully.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the AC is present.


...................................................................................................................................................................................................

3 At the RNC, check whether the AC is powered on.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-21
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance AC_communicationFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, check if there are ESC alarms and correct ESC failures.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the RNC, reset the AC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the AC object.


...................................................................................................................................................................................................

7 At the RNC, replace the Alarm Card.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the AC object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-22 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

AC_softwareVersionMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the AC_softwareVersionMismatch alarm.

Description
The software version running on this processor does not match the provisioned
software version.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A software installation failed or has not initiated.

System impact
Processor may not initialize properly.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Install the provisioned software version on the processor.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-23
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Common Intelligent
Carrier Card (CICC).

Contents

CICC_degradeGroupMemberFault 16-25
CICC_escalatingRecovery 16-27
CICC_failureGroupMemberFault 16-29
CICC_lossOfPower 16-31
CICC_lossOfSanity 16-33
CICC_lostCommunication 16-35
CICC_maintenanceMode 16-37
CICC_notInstalled 16-38
CICC_overTemperature 16-40
CICC_overTemperatureInFlow 16-42
CICC_overTemperatureOutFlow 16-44

...................................................................................................................................................................................................................................
16-24 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_degradeGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_degradeGroupMemberFault
alarm.

Description
A member of the Common Intelligent Carrier Card (CICC) degrade group failed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A member of a degrade group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the CICC to go degraded (operationalState
Enabled and availabilityStatus Degraded).
The members of the CICC degrade group are:
• The 2 non-main processors (CICCProc 1 and CICCProc 2)
• All backplane Ethernet ports (CICCBPEtherPort)

System impact
The CICC is considered degraded.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-25
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_degradeGroupMemberFault
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the objects:


• CICCProc 1 or CICCProc 2
• CICCBPEtherPort
If there are alarms, perform the appropriate fault clearance procedure.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-26 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_escalatingRecovery
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_escalatingRecovery alarm.

Description
The system is escalating recovery of the Common Intelligent Carrier Card (CICC) and
may have exhausted attempts to recover the unit.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The CICC is not responding to recovery due to software or hardware failure.

System impact
Voice and data handling traffic handling capacity decreased.

Automatic corrective actions


The system will attempt to reset the unit. If reset attempts fail, the unit will be
powered down.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


the additional alarm text monitor and verify that the unit recovers to a
indicates that the unit is being normal state.
reset ,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-27
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_escalatingRecovery
procedures

If ... then ...


the additional alarm text check for other alarms associated with this unit
indicates that the unit has been (CICC_lossOfPower, CICC_lossOfSanity,
powered off, CICC_lostCommunication etc) and carry out the
appropriate procedure.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-28 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_failureGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_failureGroupMemberFault
alarm.

Description
A member of the Common Intelligent Carrier Card (CICC) failure group failed.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
A member of a failure group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the CICC to fail (operationalState Disabled
and availabilityStatus Failed).
The member of the CICC failure group is:
• The main processor (CICCProc 0)

System impact
The CICC is not operational.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the object:


• CICCProc
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-29
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_failureGroupMemberFault
procedures

If there are alarms, perform the appropriate fault clearance procedure.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-30 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_lossOfPower
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_lossOfPower alarm.

Description
The Common Intelligent Carrier Card (CICC) has lost power.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment problem.

System impact
No direct system impact.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the CICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the CICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-31
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_lossOfPower
procedures

...................................................................................................................................................................................................

3 At the RNC, if the CICC is inserted in the correct slot, remove and re-insert the CICC.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-32 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_lossOfSanity
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_lossOfSanity alarm.

Description
The Common Intelligent Carrier Card (CICC) lost sanity or integrity.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The Alarm Card did not detect a board healthy signal from the CICC.

System impact
The CICC is inoperative and the capacity to handle voice and data traffic decreases.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check if a maintenanceMode alarm is active.


...................................................................................................................................................................................................

2 At the RNC, check whether the CICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-33
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_lossOfSanity
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CICC object.


...................................................................................................................................................................................................

5 At the RNC, replace the CICC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-34 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_lostCommunication
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_lostCommunication alarm.

Description
Alarm Card (AC) lost heartbeat communication to the Common Intelligent Carrier
Card (CICC).

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Equipment problem.

System impact
The CICC may operate but will likely not respond to some OA&M commands,
especially those entered through the CLI.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether the CICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the CICC is inserted in the correct slot, remove and re-insert the CICC.
If the alarm is cleared,the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-35
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICC_lostCommunication
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CICC object.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the CICC object.


...................................................................................................................................................................................................

5 At the RNC, replace the CICC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the CICC object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-36 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICC_maintenanceMode
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_maintenanceMode alarm.

Description
The Common Intelligent Carrier Card (CICC) is in maintenance mode.

Default severity
Warning

Alarm type
processingErrorAlarm

Root cause
Configuration problem.

System impact
Alarm Card recovery for this CICC is inhibited.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, use the maintenance terminal to put the CICC back into active mode.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-37
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICC_notInstalled
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_notInstalled alarm.

Description
Common Intelligent Carrier Card (CICC) is not properly installed in the shelf slot.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The specified CICC is physically removed from the shelf or is not correctly inserted
and the Alarm Card does not detect the CICC.

System impact
The CICC is inoperative and the capacity to handle voice and data traffic decreases.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, if the CICC is not inserted, insert the CICC into the correct slot .
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the CICC is inserted in the correct slot, remove and re-insert the CICC.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-38 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICC_notInstalled
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the CICC object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-39
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICC_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_overTemperature alarm.

Description
The temperature is above the specified limit.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-40 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICC_overTemperature
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-41
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICC_overTemperatureInFlow
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_overTemperatureInFlow
alarm.

Description
The inflow temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-42 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICC_overTemperatureInFlow
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-43
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICC_overTemperatureOutFlow
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICC_overTemperatureOutFlow
alarm.

Description
The outflow temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-44 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICC_overTemperatureOutFlow
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-45
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the CICC Ethernet port
alarms.

Contents

CICCBPEtherPort_communicationFailureESC1_2 16-47
CICCBPEtherPort_communicationFailureESC1_21 16-49
CICCBPEtherPort_communicationFailureESC2_2 16-51
CICCBPEtherPort_communicationFailureESC2_21 16-53
CICCBPEtherPort_linkFailure 16-55
CICCBPEtherPort_restoreServiceFailure 16-57

...................................................................................................................................................................................................................................
16-46 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_communicationFailureESC1_2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_communication-
FailureESC1_2 alarm.

Description
Ethernet communication to shelf 1, ESC 2 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• CICC hardware failure
• Cable failures

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-47
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_communicationFailureESC1_2
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one CICC on shelf 1 (not replace the CICC.
on shelf 2) reports this alarm on
its BPEtherPort 0,
multiple shelf 1 GICCs and replace the ESC 2 on shelf 1.
CICCs report this alarm on its
BPEtherPort BPEtherPort 0,
only shelf 2 (and not shelf 1) check the vertical cables that connect ESC 2 on
GICCs and CICCs report this shelf 1 with ESC 2 on shelf 2 via ESC ports 22
alarm on its BPEtherPort 0, and 23.
GICCs and CICCs report this check the diagonal cables that connect ESC 2 on
alarm on its BPEtherPort 1 (and shelf 1 with ESC 21 on shelf 2 via ESC ports 20
not on BPEtherPort 0), and 21.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-48 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_communicationFailureESC1_21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_communication-
FailureESC1_21 alarm.

Description
Ethernet communication to shelf 1, ESC 21 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• CICC hardware failure
• Cable failures

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-49
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_communicationFailureESC1_21
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one CICC on shelf 1 (not replace the CICC.
on shelf 2) reports this alarm on
its BPEtherPort 1,
multiple shelf 1 GICCs and replace the ESC 21 on shelf 1.
CICCs report this alarm on its
BPEtherPort 1,
only shelf 2 (not shelf 1) GICCs check the vertical cables that connect ESC 21 on
and CICCs report this alarm on shelf 1 with ESC 21 on shelf 2 via ESC ports 22
its BPEtherPort 0, and 23.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-50 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_communicationFailureESC2_2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_communication-
FailureESC2_2 alarm.

Description
Ethernet communication to shelf 2, ESC 2 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• CICC hardware failure
• Cable failures

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-51
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_communicationFailureESC2_2
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one CICC on shelf 2 (not replace the CICC.
on shelf 1) reports this alarm on
its BPEtherPort 0,
multiple shelf 2 GICCs and replace the ESC 2 on shelf 2.
CICCs report this alarm on its
BPEtherPort BPEtherPort 0,
only shelf 1 (and not shelf 2) check the vertical cables that connect ESC 2 on
GICCs and CICCs report this shelf 1 with ESC 2 on shelf 2 via ESC ports 22
alarm on its BPEtherPort 0, and 23.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-52 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_communicationFailureESC2_21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_communication-
FailureESC2_21 alarm.

Description
Ethernet communication to shelf 2, ESC 21 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• CICC hardware failure
• Cable failures.

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-53
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_communicationFailureESC2_21
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one CICC on shelf 2 (not replace the CICC.
on shelf 1) reports this alarm on
its BPEtherPort 1,
multiple shelf 2 (not shelf 1) replace the ESC 21 on shelf 2.
GICCs and CICCs report this
alarm on its BPEtherPort 1,
only shelf 1 (not shelf 2) GICCs check the vertical cables that connect ESC 21 on
and CICCs report this alarm on shelf 1 with ESC 21 on shelf 2 via ESC ports 22
its BPEtherPort 1, and 23.
GICCs and CICCs report this check the diagonal cables that connect ESC 2 on
alarm on its BPEtherPort 0 (and shelf 1 with ESC 21 on shelf 2 via ESC ports 20
not on BPEtherPort 1), and 21.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-54 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_linkFailure alarm.

Description
A failure occurred on the backplane ethernet link connection.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Backplane ethernet connection failure.

System impact
No communication with CICC possible.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, remove and re-insert the CICC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, replace the CICC.


...................................................................................................................................................................................................

3 At the RNC, check the backplane.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-55
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_linkFailure
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-56 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCBPEtherPort_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCBPEtherPort_restoreSer-
viceFailure alarm.

Description
Request to restore service of the Common Intelligent Carrier Card (CICC) backplane
ethernet port has failed
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
CICC not available.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, lock and unlock the CICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, replace the CICC.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-57
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCBPEtherPort_restoreServiceFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-58 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the CICC Processor
(CICCProc).

Contents

CICCProc_communicationFailure 16-60
CICCProc_communicationFailureLRM 16-62
CICCProc_configurationError 16-64
CICCProc_cpuUsageOverload 16-65
CICCProc_criticalSoftwareFailure 16-66
CICCProc_heartbeatFailure 16-68
CICCProc_memoryBlockError 16-70
CICCProc_memoryUsageOverload 16-72
CICCProc_resourceFailure 16-73
CICCProc_restoreServiceFailure 16-75
CICCProc_softwareAssertError 16-77
CICCProc_softwareVersionMismatch 16-79
CICCProc_standbyMateDown 16-81
CICCProc_switchover 16-83
CICCProc_vitalResourceFailure 16-85

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-59
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_communicationFailure
alarm.

Description
Communication to the processor of the Common Intelligent Carrier Card (CICC) has
failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
No SNMP communication between the SB and CICC.

System impact
CICC not available.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, if the CICC is initializing, ensure that the CICC restores
successfully.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the CICC is present.

...................................................................................................................................................................................................................................
16-60 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICCProc_communicationFailure
procedures

...................................................................................................................................................................................................

3 At the RNC, check whether the CICC is powered on.


...................................................................................................................................................................................................

4 At the OMC-UPS, check if there are ESC alarms and correct ESC failures.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the CICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the CICC object.


...................................................................................................................................................................................................

7 At the RNC, replace the CICC.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the CICC object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-61
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_communicationFailureLRM
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_communicationFail-
ureLRM alarm.

Description
Communication from FMS host processor to LRM on the CICC processor has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• Faulty hardware
• Bad software image
• Incorrect board installed
• An initialization is in progress

System impact
CICC processor is unavailable for use by call processing.

Automatic corrective actions


A board reset will be attempted.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If alarm has not cleared within 15 minutes, check if other boards of the same type
have successfully booted, if not, verify correct software is installed successfully.

...................................................................................................................................................................................................................................
16-62 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICCProc_communicationFailureLRM
procedures

...................................................................................................................................................................................................

2 Execute a manual reset on the associated CICC board.


...................................................................................................................................................................................................

3 At the RNC, replace the board if it has previously been inservice or verify the correct
board was installed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-63
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_configurationError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_configurationError alarm.

Description
An error was found in the configuration data used by this processor.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The data was either populated incorrectly initially, or a data change was made that
introduced the error.

System impact
Call processing may be affected.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
16-64 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_cpuUsageOverload
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_cpuUsageOverload alarm.

Description
The processor on the CICC is in CPU usage overload.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
The threshold for CPU usage overload of the processor on the CICC is exceeded.

System impact
Reduced throughput on the CICC. System audits will be inhibited.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, reduce the processing load.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-65
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_criticalSoftwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_criticalSoftwareFailure
alarm.

Description
A critical software failure has occurred.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes may be:
• A critical problem, possibly caused by a software or hardware failure, is detected
by the TPU application.
• Process failure on a remote CICC. Probably the remote CICC performs a reset.
Underlying service Data Management Framework (DMF) unavailable caused by
software or hardware failure.

System impact
Evaluate the system impact from the depending “context failure” alarms raised by
BSC:
• Active CICC failure: all calls are dropped
• Standby CICC failure: no impact

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-66 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICCProc_criticalSoftwareFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, clear any other alarm that has been reported for the same CICC
object.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the fault is reported periodically by the same CICC, at the OMC-UPS, lock the
CICC object.
...................................................................................................................................................................................................

3 At the RNC, replace the CICC.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the CICC object.


...................................................................................................................................................................................................

5 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-67
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_heartbeatFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_heartbeatFailure alarm.

Description
This fault is raised when a TPU platform heartbeat module has trouble communicating
with either peer instances or the local application.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Process failure on a remote CICC. Possible causes are:
• The remote CICC performs a reset
• A GICC reports that it cannot communicate with a CICC
• A CCC reports that it cannot communicate with a GICC

System impact
A remote CICC probably performs a reset.
The system impact depends on the type of the remote CICC card:
• Active CICC: all calls are dropped
• Standby CICC: no impact

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-68 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICCProc_heartbeatFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No action required. The error will be cleared automatically after the remote CICC has
been recovered.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-69
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_memoryBlockError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_memoryBlockError alarm.

Description
This fault is raised during early indications of memory block exhaustion (Message
Block Chain of CBUFFER).

Default severity
Major

Alarm type
qualityofServiceAlarm

Root cause
High load distributed to the CICC causing memory block exhaustion.
The high load can be an indication that the RNC is at its capacity or is nearing its
capacity and requires replanning or re-engineering.

System impact
Establishment of new calls may be refused. As long as the memory block error is not
cleared, the TPU application (C-plane) does not accept new contexts/calls on that
CICC.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that all CICC objects are unlocked and enabled.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-70 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance CICCProc_memoryBlockError
procedures

...................................................................................................................................................................................................

2 A network replanning may be necessary in case the capacity of the RNC is reached.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-71
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_memoryUsageOverload
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_memoryUsageOverload
alarm.

Description
The processor on the CICC is in memory usage overload.

Default severity
Major

Alarm type
qualityofServiceAlarm

Root cause
The threshold for memory usage overload of the processor on the CICC is exceeded.

System impact
Memory overload may degrade the system performance.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
16-72 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_resourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_resourceFailure alarm.

Description
A non-vital resource is unavailable or is out of service.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
Underlying resource unavailable caused by software or hardware failure of the
CICCBPEtherPort.

System impact
CICC not available for call processing.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the CICC object.


...................................................................................................................................................................................................

2 At the RNC, replace the CICC.


...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the CICC object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-73
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_resourceFailure
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-74 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_restoreServiceFailure
alarm.

Description
Request to restore service of the Common Intelligent Carrier Card (CICC) Processor
has failed.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
CICC processor not available.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the CICC object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-75
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_restoreServiceFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-76 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_softwareAssertError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_softwareAssertError
alarm.

Description
A software assertion error has occurred.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
An invalid condition is detected by the TPU application.

System impact
Evaluate the system impact from the depending “context failure” alarms raised by
BSC:
• Active CICC failure: all calls are dropped
• Standby CICC failure: no impact
• Calls related to the Node B contexts (NBAP/ALCAP stacks) or cell contexts
(common control channels) hosted on that card are dropped.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, perform a reset of the CICC object to reboot the CICC.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-77
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_softwareAssertError
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-78 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_softwareVersionMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_softwareVersionMismatch
alarm.

Description
The software version running on this processor does not match the provisioned
software version.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A software installation failed or has not initiated.

System impact
Processor may not initialize properly.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Install the provisioned software version on the processor.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-79
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_softwareVersionMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-80 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_standbyMateDown
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_standbyMateDown alarm.

Description
The associated Common Intelligent Carrier Card (CICC) standby mate processor is
unavailable.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Optical ATM link failure or ether fabric failure.

System impact
No redundant CICC processor available.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check the status of the CICC processor.


...................................................................................................................................................................................................

2 At the OMC-UPS, check the status of the ATM link.


...................................................................................................................................................................................................

3 At the OMC-UPS, reset the standby CICC object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-81
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_standbyMateDown
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-82 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_switchover
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_switchover alarm.

Description
A switchover of the SS7 stack has occurred from the active Signaling Processor on the
CICC in the FBP shelf to the standby Signaling Processor on the CICC in the other
FBP shelf..
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
The standby Signaling Processor detected that the active Signaling Processor has failed
and a switchover was triggered.

System impact
When the switchover to the standby Signaling Processor occurs, all calls are dropped.
When the switchover is completed, calls can be established again.
If the failing Signaling Processor remains disabled after the failure, standby Signaling
Processor is no longer available.

Automatic corrective actions


Switchover to the standby Signaling Processor occurs.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-83
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_switchover
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check whether the switchover was successful and SS7 stack is
started on the new Signaling Processor. Check whether calls can be established again.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the state of the Signaling Processor that failed:

If ... then ..
The state is unlocked and 1. the Signaling Processor that failed has
enabled, recovered successfully
2. the procedure is completed.
The state is NOT unlocked and replace the CICC that hosts the Signaling
enabled, Processor:
1. At the OMC-UPS, lock the CICC object
2. At the RNC, replace the CICC.
3. At the OMC-UPS, reset the CICC object
4. At the OMC-UPS, unlock the CICC object

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-84 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

CICCProc_vitalResourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the CICCProc_vitalResourceFailure
alarm.

Description
A vital resource is unavailable or is out of service.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
An underlying vital resource is unavailable caused by software or hardware failure of
the CICCBPEtherPort.

System impact
The CICC is not available for call processing.

Automatic corrective actions


None.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, lock the CICC object.


...................................................................................................................................................................................................

2 At the RNC, replace the CICC.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-85
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance CICCProc_vitalResourceFailure
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, unlock the CICC object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-86 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

Cabinet alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the RNC Cabinet

Contents

Cabinet_fanOrCktBreakerFailure 16-88

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-87
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

Cabinet_fanOrCktBreakerFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the Cabinet_fanOrCktBreakerFailure
alarm.

Description
A fan or circuit breaker failure has occurred.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Configuration problem.

System impact
Heating and/or power problems.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, verify cabinet power breakers and fans are operating.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
16-88 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

EDCH alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the EDCH alarms.

Contents

EDCH_configurationRequestFailed 16-90
EDCH_resourceDegradation 16-92
EDCH_resourceFailure 16-94

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-89
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

EDCH_configurationRequestFailed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the EDCH-configurationRequestFailed
alarm.

Description
CRNC detects that it was not possible to set up E-DCH services in the cell.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
A request to configure E-DCH resources in the cell has failed. This failure can be due
to any of the following reasons:
• E-DCH functionality is switched off at the RNC level.
• NodeB does not support E-DCH services.
• RNC is unable to reserve the channelisation codes required for E-DCH downlink
channels.
• A Physical Shared Channel Reconfiguration Failure message or no response was
received from the NodeB in response to a request to configure E-DCH services.
It is recommended to delete the EDCH managed object as channelization codes could
have been allocated and they should be freed and made available for R99 calls.

System impact
E-DCH calls cannot be made on the affected cell, non E-DCH calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-90 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance EDCH_configurationRequestFailed
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check if both RNC and NodeB support E-DCH.


...................................................................................................................................................................................................

2 At the OMC-UPS, check state of IuB link.


...................................................................................................................................................................................................

3 The EDCH MO must be deleted and recreated for E-DCH resources to be configured
again.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-91
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

EDCH_resourceDegradation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the EDCH-resourceDegradation alarm.

Description
A Service Impacting NBAP RSI message was received from the NodeB which
indicates that the E-DCH resources were degraded.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
A Service Impacting NBAP RSI message was received from the NodeB, which
indicates that the E-DCH resources were degraded. E-DCH calls are still possible, but
the full quota of E-DCH calls is not possible until the problem is fixed.

System impact
E-DCH calls can be made on the affected cell but the faulty equipment will restrict the
number of such calls, non E-DCH calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms from the NodeB, take corrective actions to resolve
hardware failures that affect the functioning of a cell.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-92 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance EDCH_resourceDegradation
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-93
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

EDCH_resourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the EDCH-resourceFailure alarm.

Description
A hardware failure at the NodeB resulted in E-DCH failure.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
A hardware failure at the NodeB, which resulted in a change in the E-DCH capability
of the cell, has been communicated to the CRNC via the Cell Information->E-DCH
Resources Information element in the Service Impacting NBAP RSI message.

System impact
E-DCH calls cannot be made on the affected cell, non E-DCH calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms from the NodeB, take corrective actions to resolve
hardware failures that affect the functioning of a cell.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the E-DCH fault cannot be rectified immediately, it is recommended to delete the


EDCH managed object so that channelization codes will be available for R99 calls.
...................................................................................................................................................................................................................................
16-94 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance EDCH_resourceFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-95
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Ethernet Switching Card
(ESC) alarms.

Contents

ESC_degradeGroupMemberFault 16-97
ESC_failureGroupMemberFault 16-99
ESC_lossOfPower 16-101
ESC_lossOfSanity 16-103
ESC_lostCommunication 16-105
ESC_maintenanceMode 16-107
ESC_notInstalled 16-108
ESC_overTemperature 16-110
ESCProc_softwareVersionMismatch 16-112

...................................................................................................................................................................................................................................
16-96 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_degradeGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_degradeGroupMemberFault
alarm.

Description
A member of the Ethernet Switching Card (ESC) degrade group failed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A member of a degrade group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the ESC to go degraded (operationalState
Enabled and availabilityStatus Degraded).
The members of the ESC degrade group are:
• All backplane Ethernet ports (ESCBPEtherPort)
• All front access Ethernet ports (ESCFAEtherPort)

System impact
The ESC is considered degraded.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-97
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESC_degradeGroupMemberFault
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the objects:


• ESCBPEtherPort
• ESCFAEtherPort
If there are alarms, perform the appropriate fault clearance procedure.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-98 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_failureGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_failureGroupMemberFault
alarm.

Description
A member of the Ethernet Switching Card (ESC) failure group failed.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
A member of a failure group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the ESC to fail (operationalState Disabled
and availabilityStatus Failed).
The member of the ESC failure group is:
• The ESC processor (ESCProc)

System impact
The ESC is not operational.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the object:


• ESCProc
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-99
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESC_failureGroupMemberFault
procedures

If there are alarms, perform the appropriate fault clearance procedure.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-100 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_lossOfPower
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_lossOfPower alarm.

Description
The Ethernet Switching Card (ESC) has lost power.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
No power available at ESC.

System impact
This ESC can provide internal and external ethernet connectivity. The redundant ESC
will take over the switching tasks.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether the ESC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the ESC is inserted in the correct slot, remove and re-insert the ESC.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-101
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESC_lossOfPower
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the ESC object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-102 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_lossOfSanity
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_lossOfSanity alarm.

Description
The Ethernet Switch Card (ESC) lost sanity or integrity.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The Alarm Card did not detect a board healthy signal from the ESC.

System impact
None, the redundant ESC will take over the switching tasks.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check if a maintenanceMode alarm is active.


...................................................................................................................................................................................................

2 At the RNC, check whether the ESC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the ESC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-103
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESC_lossOfSanity
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the ESC object.


...................................................................................................................................................................................................

5 At the RNC, replace the ESC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the ESC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-104 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_lostCommunication
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_lostCommunication alarm.

Description
The Alarm Card (AC) lost heartbeat communication to the Ethernet Switching Card
(ESC).

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Equipment problem.

System impact
None

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether the ESC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed..
...................................................................................................................................................................................................

2 At the RNC, if the ESC is inserted in the correct slot, remove and re-insert the ESC.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-105
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESC_lostCommunication
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the ESC.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the ESC object.


...................................................................................................................................................................................................

5 At the RNC, replace the ESC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the ESC object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-106 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESC_maintenanceMode
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_maintenanceMode alarm.

Description
The Ethernet Switching Card (ESC) is in maintenance mode.

Default severity
Warning

Alarm type
processingErrorAlarm

Root cause
Configuration problem.

System impact
Alarm Card recovery for the ESC is inhibited.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, use the local maintenance terminal to put the ESC back into active mode.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-107
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESC_notInstalled
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_notInstalled alarm.

Description
The Ethernet Switching Card (ESC) is not properly installed in the shelf slot.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The specified ESC is physically removed from the shelf or is not correctly inserted and
the Alarm Card does not detect the ESC.

System impact
None, the other ESC takes over.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, if the ESC is not inserted, insert the ESC into the correct slot.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the ESC is inserted in the correct slot, remove and re-insert the ESC.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-108 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance ESC_notInstalled
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the ESC object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-109
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESC_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESC_overTemperature alarm.

Description
The temperature is above the specified limit.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-110 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance ESC_overTemperature
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-111
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESCProc_softwareVersionMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESCProc_softwareVersionMismatch
alarm.

Description
The software version running on this processor does not match the provisioned
software version.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A software installation failed or has not initiated.

System impact
Processor may not initialize properly.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Install the provisioned software version on the processor.

...................................................................................................................................................................................................................................
16-112 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance ESCProc_softwareVersionMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-113
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESCBPEtherPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Ethernet Switching Card
BackPlane Ethernet port alarms.

Contents

ESCBPEtherPort_linkFailure 16-115

...................................................................................................................................................................................................................................
16-114 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESCBPEtherPort_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESCBPEtherPort_linkFailure alarm.

Description
A failure occurred on the backplane ethernet link connection.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Backplane ethernet connection failure

System impact
None, the other ESC takes over.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, remove and re-insert the ESC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, replace the ESC.


...................................................................................................................................................................................................

3 At the RNC, check the backplane.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-115
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESCBPEtherPort_linkFailure
procedures

...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-116 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESCFAEtherPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Ethernet Switching Card
Front Access Ethernet port alarms.

Contents

ESCFAEtherPort_linkFailure 16-118

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-117
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESCFAEtherPort_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESCFAEtherPort_linkFailure alarm.

Description
A failure occurred on the frontplate Ethernet link connection.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Frontplane Ethernet connection failure

System impact
Communication over the Ethernet link connections fails.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical Ethernet link connection on the frontplate.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, replace the ESC.

...................................................................................................................................................................................................................................
16-118 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance ESCFAEtherPort_linkFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-119
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

ESCProc alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Ethernet Switching Card
processor alarms.

Contents

ESCProc_communicationFailure 16-121

...................................................................................................................................................................................................................................
16-120 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ESCProc_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ESCProc_communicationFailure
alarm.

Description
Communication to the Ethernet Switch Card (ESC) processor has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
No SNMP communication between the SB and ESC.

System impact
No internal and external ethernet connectivity is provided by the ESC.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, if the ESC is initializing, ensure that the ESC restores successfully.
If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the ESC is present.


...................................................................................................................................................................................................

3 At the RNC, check whether the ESC is powered on.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-121
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ESCProc_communicationFailure
procedures

...................................................................................................................................................................................................

4 At the RNC, reset the ESC.


If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, lock the ESC object.


...................................................................................................................................................................................................

6 At the RNC, replace the ESC.


...................................................................................................................................................................................................

7 At the OMC-UPS, unlock the ESC object.


...................................................................................................................................................................................................

8 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-122 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the External Alarm Box.

Contents

ExtAlmBox_communicationFailure 16-125
ExtAlmBox_externalAlarmPort1 16-127
ExtAlmBox_externalAlarmPort10 16-129
ExtAlmBox_externalAlarmPort11 16-131
ExtAlmBox_externalAlarmPort12 16-133
ExtAlmBox_externalAlarmPort13 16-135
ExtAlmBox_externalAlarmPort14 16-137
ExtAlmBox_externalAlarmPort15 16-139
ExtAlmBox_externalAlarmPort16 16-141
ExtAlmBox_externalAlarmPort17 16-143
ExtAlmBox_externalAlarmPort18 16-145
ExtAlmBox_externalAlarmPort19 16-147
ExtAlmBox_externalAlarmPort2 16-149
ExtAlmBox_externalAlarmPort20 16-151
ExtAlmBox_externalAlarmPort21 16-153
ExtAlmBox_externalAlarmPort22 16-155
ExtAlmBox_externalAlarmPort23 16-157
ExtAlmBox_externalAlarmPort24 16-159
ExtAlmBox_externalAlarmPort25 16-161
ExtAlmBox_externalAlarmPort26 16-163
ExtAlmBox_externalAlarmPort27 16-165
ExtAlmBox_externalAlarmPort28 16-167
ExtAlmBox_externalAlarmPort29 16-169
ExtAlmBox_externalAlarmPort3 16-171

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-123
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance Overview
procedures

ExtAlmBox_externalAlarmPort30 16-173
ExtAlmBox_externalAlarmPort31 16-175
ExtAlmBox_externalAlarmPort32 16-177
ExtAlmBox_externalAlarmPort4 16-179
ExtAlmBox_externalAlarmPort5 16-181
ExtAlmBox_externalAlarmPort6 16-183
ExtAlmBox_externalAlarmPort7 16-185
ExtAlmBox_externalAlarmPort8 16-187
ExtAlmBox_externalAlarmPort9 16-189

....................................................................................................................................................................................................................................
16-124 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_communicationFailure
alarm.

Description
A communication failure to the External Alarm Box has occurred.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Connectivity is lost between the RNC and the External Alarm Box.

System impact
No alarms from the External Alarm Box will be reported to the OMC-UPS.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the RNC, make sure that the connection between the RNC and the External Alarm
Box is OK.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-125
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_communicationFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-126 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort1
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort1
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 1.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-127
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort1
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-128 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort10
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort10
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 10.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-129
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort10
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-130 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort11
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort11
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 11.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-131
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort11
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-132 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort12
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort12
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 12.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-133
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort12
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-134 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort13
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort13
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 13.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-135
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort13
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-136 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort14
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort14
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 14.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-137
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort14
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-138 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort15
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort15
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 15.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-139
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort15
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-140 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort16
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort16
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 16.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-141
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort16
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-142 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort17
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort17
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 17.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-143
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort17
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-144 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort18
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort18
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 18.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-145
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort18
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-146 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort19
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort19
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 19.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-147
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort19
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-148 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort2
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 2.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-149
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort2
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-150 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort20
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort20
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 20.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-151
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort20
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-152 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort21
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 21.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-153
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort21
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-154 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort22
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort22
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 22.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-155
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort22
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-156 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort23
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort23
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 23.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-157
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort23
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-158 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort24
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort24
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 24.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-159
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort24
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-160 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort25
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort25
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 25.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-161
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort25
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-162 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort26
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort26
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 26.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-163
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort26
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-164 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort27
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort27
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 27.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-165
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort27
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-166 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort28
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort28
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 28.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-167
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort28
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-168 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort29
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort29
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 29.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-169
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort29
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-170 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort3
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort3
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 3.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-171
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort3
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-172 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort30
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort30
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 30.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-173
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort30
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-174 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort31
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort31
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 31.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-175
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort31
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-176 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort32
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort32
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 32.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-177
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort32
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-178 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort4
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort4
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 4.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-179
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort4
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-180 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort5
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort5
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 5.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-181
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort5
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-182 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort6
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort6
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 6.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-183
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort6
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-184 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort7
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort7
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 7.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-185
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort7
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-186 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort8
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort8
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 8.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-187
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort8
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-188 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

ExtAlmBox_externalAlarmPort9
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the ExtAlmBox_externalAlarmPort9
alarm.

Description
The condition that is monitored using this external alarm port is active.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
This alarm was triggered by the external equipment connected to External Alarm Box
(EAB) port 9.

System impact
Dependent on the external equipment connected to the port.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Request a service technician to take action. The action depends upon the site-specific
configuration and the external equipment that is connected to the external alarm port.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-189
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance ExtAlmBox_externalAlarmPort9
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-190 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the FBP shelf alarms.

Contents

FBPShelf_overTemperature 16-192
FBPShelf_overTemperatureSensor1 16-194
FBPShelf_overTemperatureSensor2 16-196
FBPShelf_overTemperatureSensor3 16-198
FBPShelf_overTemperatureSensor4 16-200
FBPShelf_overTemperatureSensor5 16-202
FBPShelf_overTemperatureSensor6 16-204
FBPShelf_overTemperatureSensor7 16-206
FBPShelf_overTemperatureSensor8 16-208

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-191
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperature alarm.

Description
The temperature is above the specified limit.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


The fan speed may be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated overTemperature alarms on any
individual cards using the appropriate clearance procedures
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-192 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperature
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

4 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

5 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

6 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-193
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor1
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor1
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-194 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor1
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-195
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor2
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-196 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor2
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-197
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor3
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor3
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-198 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor3
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-199
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor4
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor4
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-200 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor4
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-201
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor5
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor5
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-202 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor5
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-203
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor6
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor6
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-204 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor6
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-205
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor7
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor7
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-206 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor7
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-207
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FBPShelf_overTemperatureSensor8
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FBPShelf_overTemperatureSensor8
alarm.

Description
The temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-208 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance FBPShelf_overTemperatureSensor8
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-209
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

FanTray alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the FanTray unit.

Contents

FanTray_fan1Failure 16-211
FanTray_fan2Failure 16-213
FanTray_fan3Failure 16-215
FanTray_notInstalled 16-217

...................................................................................................................................................................................................................................
16-210 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

FanTray_fan1Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FanTray_fan1Failure alarm.

Description
The fan 1 is not functioning properly. The fan is not rotating or is not rotating at the
proper speed.

Default severity
1 is not rotating at the proper speed.

Alarm type
Alarm type is unknown.

Root cause
Possible root causes are:
• Objects blocking the rotation of the fan
• Fan defect.

System impact
No or insufficient cooling facilities available. This can lead to hardware failures
because of high temperatures.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check the status of the fan tray.


...................................................................................................................................................................................................

2 At the RNC, inspect the fan tray and remove any object that obstruct the rotation of
the fan.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-211
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance FanTray_fan1Failure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the RNC, replace the fan tray.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-212 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

FanTray_fan2Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FanTray_fan2Failure alarm.

Description
The fan 2 is not functioning properly. The fan is not rotating or is not rotating at the
proper speed.

Default severity
2 is not rotating at the proper speed.

Alarm type
Alarm type is unknown.

Root cause
Possible root causes are:
• Objects blocking the rotation of the fan
• Fan defect.

System impact
No or insufficient cooling facilities available. This can lead to hardware failures
because of high temperatures.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check the status of the fan tray.


...................................................................................................................................................................................................

2 At the RNC, inspect the fan tray and remove any object that obstruct the rotation of
the fan.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-213
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance FanTray_fan2Failure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the RNC, replace the fan tray.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-214 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

FanTray_fan3Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FanTray_fan3Failure alarm.

Description
The fan 3 is not functioning properly. The fan is not rotating or is not rotating at the
proper speed.

Default severity
3 is not rotating at the proper speed.

Alarm type
Alarm type is unknown.

Root cause
Possible root causes are:
• Objects blocking the rotation of the fan
• Fan defect.

System impact
No or insufficient cooling facilities available. This can lead to hardware failures
because of high temperatures.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check the status of fan tray.


...................................................................................................................................................................................................

2 At the RNC, inspect the fan tray and remove any object that obstruct the rotation of
the fan.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-215
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance FanTray_fan3Failure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the RNC, replace the fan tray.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-216 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

FanTray_notInstalled
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the FanTray_notInstalled alarm.

Description
The fan tray is not installed.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Fan tray not installed

System impact
No cooling facilities available

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, install a fan tray unit.


...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-217
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICC alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Gateway Intelligent
Carrier Card (GICC).

Contents

GICC_degradeGroupMemberFault 16-219
GICC_escalatingRecovery 16-221
GICC_failureGroupMemberFault 16-223
GICC_lossOfPower 16-225
GICC_lossOfSanity 16-227
GICC_lostCommunication 16-229
GICC_maintenanceMode 16-231
GICC_notInstalled 16-232
GICC_overTemperature 16-234
GICC_overTemperatureInFlow 16-236
GICC_overTemperatureOutFlow 16-238

...................................................................................................................................................................................................................................
16-218 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_degradeGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_degradeGroupMemberFault
alarm.

Description
A member of the Gateway Intelligent Carrier Card (GICC) degrade group failed.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A member of a degrade group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the GICC to go degraded (operationalState
Enabled and availabilityStatus Degraded).
The members of the GICC degrade group are:
• All STM1/OC3 ports (GICCSTM1OC3Port)
• All backplane Ethernet ports (GICCBPEtherPort)
• All front access Ethernet ports (GICCFAEtherPort)

System impact
The GICC is considered degraded.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-219
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_degradeGroupMemberFault
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the objects:


• GICCSTM1OC3Port
• GICCFAEtherPort
• GICCBPEtherPort
If there are alarms, perform the appropriate fault clearance procedure.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-220 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_escalatingRecovery
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_escalatingRecovery alarm.

Description
The system is escalating recovery of the Gateway Intelligent Carrier Card (GICC) and
may have exhausted attempts to recover the unit,
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The GICC is not responding to recovery due to software or hardware failure

System impact
None. The other GICC will take over

Automatic corrective actions


The system will attempt to reset the unit. If reset attempts fail, the unit will be
powered down.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


the additional alarm text monitor and verify that the unit recovers to a
indicates that the unit is being normal state.
reset ,

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-221
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_escalatingRecovery
procedures

If ... then ...


the additional alarm text check for other alarms associated with this unit
indicates that the unit has been (GICC_lossOfPower, GICC_lossOfSanity,
powered off, GICC_lostCommunication etc) and carry out the
appropriate procedure.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-222 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_failureGroupMemberFault
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_failureGroupMemberFault
alarm.

Description
A member of the Gateway Intelligent Carrier Card (GICC) failure group failed.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
A member of a failure group faulted (operationalState Disabled and
availabilityStatus Failed). This causes the GICC to fail (operationalState Disabled
and availabilityStatus Failed).
The member of the GICC failure group is:
• The GICC processor (GICCProc)

System impact
The GICC is not operational.
The system impact depends on the rootcause of the alarm.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on the object:


• GICCProc
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-223
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_failureGroupMemberFault
procedures

If there are alarms, perform the appropriate fault clearance procedure.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-224 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_lossOfPower
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_lossOfPower alarm.

Description
The Gateway Intelligent Carrier Card (GICC) has lost power.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Equipment problem

System impact
None.

Automatic corrective actions


The other GICC will take over.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the GICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-225
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_lossOfPower
procedures

...................................................................................................................................................................................................

3 At the RNC, if the GICC is inserted in the correct slot, remove and re-insert the GICC.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-226 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_lossOfSanity
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedures for clearing the GICC_lossOfSanity alarm.

Description
The Gateway Inteligent Carrier Card (GICC) lost sanity or integrity.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
The Alarm Card did not detect a board healthy signal from the GICC.

System impact
None.

Automatic corrective actions


A standby GICC takes over.

Before you begin


There is no additional information required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check if a maintenanceMode alarm is active.


...................................................................................................................................................................................................

2 At the RNC, check whether the GICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, reset the GICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-227
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_lossOfSanity
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, lock the GICC object.


...................................................................................................................................................................................................

5 At the RNC, replace the GICC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the GICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-228 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_lostCommunication
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_lostCommunication alarm.

Description
Alarm Card (AC) lost heartbeat communication to the Gateway Intelligent Carrier Card
(GICC).

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Equipment problem.

System impact
The GICC may operate but will likely not respond to some OA&M commands,
especially those entered through the CLI.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check whether the GICC is inserted into correct slot and powered on.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the GICC is inserted in the correct slot, remove and re-insert the GICC.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-229
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICC_lostCommunication
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the GICC object.


...................................................................................................................................................................................................

4 At the OMC-UPS, lock the GICC object.


...................................................................................................................................................................................................

5 At the RNC, replace the GICC.


...................................................................................................................................................................................................

6 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-230 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICC_maintenanceMode
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_maintenanceMode alarm.

Description
The Gateway Intelligent Carrier Card (GICC) is in maintenance mode.

Default severity
Warning

Alarm type
processingErrorAlarm

Root cause
Configuration problem.

System impact
Alarm Card recovery for this GICC is inhibited.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, use the maintenance terminal to put the GICC back into active mode.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-231
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICC_notInstalled
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_notInstalled alarm.

Description
Gateway Intelligent Carrier Card is not properly installed in shelf slot.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The specified GICC is physically removed from the shelf or is not correctly inserted
and the Alarm Card does not detect the GICC.

System impact
None.

Automatic corrective actions


A standby GICC takes over.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, if the GICC is not inserted, insert the GICC into the correct slot.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, if the GICC is inserted in the correct slot, remove and re-insert the GICC.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-232 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICC_notInstalled
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, reset the GICC object.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-233
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICC_overTemperature
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_overTemperature alarm.

Description
The temperature is above the specified limit.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-234 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICC_overTemperature
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-235
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICC_overTemperatureInFlow
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_overTemperatureInFlow
alarm.

Description
The inflow temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-236 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICC_overTemperatureInFlow
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-237
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICC_overTemperatureOutFlow
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICC_overTemperatureOutFlow
alarm.

Description
The outflow temperature is above the specified limit.

Default severity
Critical

Alarm type
environmentalAlarm

Root cause
Possible causes are:
• Defective circuit boards
• Airflow obstruction or diversion
• Fan or temperature sensor failure.

System impact
Increase in cabinet temperature could lead to possible component failure.

Automatic corrective actions


Components may be automatically powered down to reduce heat. The fan speed may
be increased.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for and clear any associated fan alarms using the appropriate
clearance procedures
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-238 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICC_overTemperatureOutFlow
procedures

...................................................................................................................................................................................................

2 At the RNC, check for obstructions in the air flow pathways.


...................................................................................................................................................................................................

3 At the RNC, check if the Rear Transition Module (RTM) is correctly installed.
...................................................................................................................................................................................................

4 At the RNC, check if any empty card slots have missing or incorrectly installed filler
plates.
...................................................................................................................................................................................................

5 At the RNC, verify that the temperature sensors are functioning correctly by replacing
the card.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-239
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the GICC backplane Ethernet
port alarms.

Contents

GICCBPEtherPort_communicationFailureESC1_2 16-241
GICCBPEtherPort_communicationFailureESC1_21 16-243
GICCBPEtherPort_communicationFailureESC2_2 16-245
GICCBPEtherPort_communicationFailureESC2_21 16-247
GICCBPEtherPort_linkFailure 16-249
GICCBPEtherPort_restoreServiceFailure 16-251

...................................................................................................................................................................................................................................
16-240 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_communicationFailureESC1_2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_communication-
FailureESC1_2 alarm.

Description
Ethernet communication to shelf 1, ESC 2 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• GICC hardware failure
• Cable failures.

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-241
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_communicationFailureESC1_2
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one GICC on shelf 1 (not replace the GICC.
on shelf 2) reports this alarm on
its BPEtherPort 0,
multiple shelf 1 GICCs and replace the ESC 2 on shelf 1.
CICCs report this alarm on its
BPEtherPort BPEtherPort 0,
only shelf 2 (and not shelf 1) check the vertical cables that connect ESC 2 on
GICCs and CICCs report this shelf 1 with ESC 2 on shelf 2 via ESC ports 22
alarm on its BPEtherPort 0, and 23.
GICCs and CICCs report this check the diagonal cables that connect ESC 2 on
alarm on its BPEtherPort 1 (and shelf 1 with ESC 21 on shelf 2 via ESC ports 20
not on BPEtherPort 0), and 21.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-242 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_communicationFailureESC1_21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_communication-
FailureESC1_21 alarm.

Description
Ethernet communication to shelf 1, ESC 21 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• GICC hardware failure
• Cable failures.

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-243
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_communicationFailureESC1_21
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one GICC on shelf 1 (not replace the GICC.
on shelf 2) reports this alarm on
its BPEtherPort 1,
multiple shelf 1 GICCs and replace the ESC 21 on shelf 1.
CICCs report this alarm on its
BPEtherPort 1,
only shelf 2 (not shelf 1) GICCs check the vertical cables that connect ESC 21 on
and CICCs report this alarm on shelf 1 with ESC 21 on shelf 2 via ESC ports 22
its BPEtherPort 0, and 23.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-244 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_communicationFailureESC2_2
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_communication-
FailureESC2_2 alarm.

Description
Ethernet communication to shelf 2, ESC 2 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• GICC hardware failure
• Cable failures.

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-245
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_communicationFailureESC2_2
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one GICC on shelf 2 (not replace the GICC.
on shelf 1) reports this alarm on
its BPEtherPort 0,
multiple shelf 2 GICCs and replace the ESC 2 on shelf 2.
CICCs report this alarm on its
BPEtherPort BPEtherPort 0,
only shelf 1 (and not shelf 2) check the vertical cables that connect ESC 2 on
GICCs and CICCs report this shelf 1 with ESC 2 on shelf 2 via ESC ports 22
alarm on its BPEtherPort 0, and 23.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-246 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_communicationFailureESC2_21
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_communication-
FailureESC2_21 alarm.

Description
Ethernet communication to shelf 2, ESC 21 has failed.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• ESC hardware failure
• GICC hardware failure
• Cable failures.

System impact
No direct impact, the alternate fabric is used to provide Ethernet communication.
However the card is now vulnerable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-247
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_communicationFailureESC2_21
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If ... then ...


only one GICC on shelf 2 (not replace the GICC.
on shelf 1) reports this alarm on
its BPEtherPort 1,
multiple shelf 2 (not shelf 1) replace the ESC 21 on shelf 2.
GICCs and CICCs report this
alarm on its BPEtherPort 1,
only shelf 1 (not shelf 2) GICCs check the vertical cables that connect ESC 21 on
and CICCs report this alarm on shelf 1 with ESC 21 on shelf 2 via ESC ports 22
its BPEtherPort 1, and 23.
GICCs and CICCs report this check the diagonal cables that connect ESC 2 on
alarm on its BPEtherPort 0 (and shelf 1 with ESC 21 on shelf 2 via ESC ports 20
not on BPEtherPort 1), and 21.

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-248 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_linkFailure alarm.

Description
A failure occurred on the backplane ethernet link connection.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Ethernet link connection failure

System impact
No communication with GICC possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, reseat the GICC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, replace the GICC.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-249
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_linkFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-250 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCBPEtherPort_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCBPEtherPort_restoreSer-
viceFailure alarm.

Description
Request to restore service of the GICC Ether port has failed

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
GICC processor not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.


If the alarm is cleared the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the GICC object.


...................................................................................................................................................................................................

3 At the RNC, replace the GICC.


...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-251
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCBPEtherPort_restoreServiceFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-252 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCFAEtherPort alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the GICC front access
Ethernet port alarms.

Contents

GICCFAEtherPort_linkFailure 16-254
GICCFAEtherPort_restoreServiceFailure 16-256

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-253
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCFAEtherPort_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCFAEtherPort_linkFailure alarm.

Description
A failure occurred on the front access ethernet link connection.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
Ethernet link connection failure

System impact
No communication with GICC possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, reset the GICC.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the GICC object.


...................................................................................................................................................................................................

3 At the RNC, replace the GICC.

...................................................................................................................................................................................................................................
16-254 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCFAEtherPort_linkFailure
procedures

...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-255
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCFAEtherPort_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCFAEtherPort_restoreSer-
viceFailure alarm.

Description
Request to restore service of the GICC front access Ethernet port has failed.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
GICC processor not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.


If the alarm is cleared the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the GICC object.

...................................................................................................................................................................................................................................
16-256 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCFAEtherPort_restoreServiceFailure
procedures

...................................................................................................................................................................................................

3 At the RNC, replace the GICC.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-257
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the GICCProc.

Contents

GICCProc_allOpticalLinksFailed 16-259
GICCProc_communicationFailure 16-261
GICCProc_communicationFailureLRM 16-263
GICCProc_configurationError 16-265
GICCProc_cpuUsageOverload 16-266
GICCProc_criticalSoftwareFailure 16-267
GICCProc_heartbeatFailure 16-269
GICCProc_memoryBlockError 16-271
GICCProc_memoryUsageOverload 16-273
GICCProc_resourceFailure 16-274
GICCProc_restoreServiceFailure 16-276
GICCProc_softwareAssertError 16-278
GICCProc_softwareVersionMismatch 16-280
GICCProc_standbyMateDown 16-282
GICCProc_vitalResourceFailure 16-284

...................................................................................................................................................................................................................................
16-258 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_allOpticalLinksFailed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_allOpticalLinksFailed
alarm.

Description
All STM1/OC3 optical links on a GICC have failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible network configuration problem, physical link failure, or the GICC has been
locked

System impact
No reduncancy is available for the optical links assigned to the GICC. Any optical link
failure on the mated GICC will result in complete loss of communication for that link

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms on individual optical links and perform the
appropriate procedures to clear them.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-259
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_allOpticalLinksFailed
procedures

...................................................................................................................................................................................................

2 If there are no optical link failure alarms, but the GICC has been manually locked,
unlock the GICC object.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-260 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_communicationFailure
alarm.

Description
Communication to the Gateway Intelligent Carrier Card (GICC) processor has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
No SNMP communication between the SB and GICC.

System impact
GICC is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, if the GICC is initializing, ensure that the GICC restores
successfully.
If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

2 At the RNC, check whether the GICC is present.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-261
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_communicationFailure
procedures

...................................................................................................................................................................................................

3 At the RNC, check whether the GICC is powered on.


...................................................................................................................................................................................................

4 At the OMC-UPS, check if there are ESC alarms and correct ESC failures.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, reset the GICC object.


If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, lock the GICC object.


...................................................................................................................................................................................................

7 At the RNC, replace the GICC.


...................................................................................................................................................................................................

8 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

9 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-262 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_communicationFailureLRM
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_communicationFail-
ureLRM alarm.

Description
Communication from FMS host processor to LRM on the GICC processor has failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• Faulty hardware.
• Bad software image.
• Incorrect board installed.
• An initialization is in progress.

System impact
GICC processor is unavailable for use by call processing.

Automatic corrective actions


A board reset will be attempted

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 If the alarm has not cleared within 15 minutes, check if other boards of the same type
have successfully booted, if not, verify correct software is installed successfully.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-263
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_communicationFailureLRM
procedures

...................................................................................................................................................................................................

2 Execute a manual reset on the associated GICC board.


...................................................................................................................................................................................................

3 At the RNC, replace the board if it has previously been inservice or verify the correct
board was installed.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-264 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_configurationError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_configurationError alarm.

Description
An error was found in the configuration data used by this processor.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The data was either populated incorrectly initially, or a data change was made that
introduced the error.

System impact
Call processing may be affected.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-265
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_cpuUsageOverload
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_cpuUsageOverload alarm.

Description
The processor on the GICC is in CPU usage overload.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
The threshold for CPU usage overload of the processor on the GICC is exceeded.

System impact
Reduced throughput on the GICC. System audits will be inhibited.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, reduce the processing load.


...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
16-266 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_criticalSoftwareFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_criticalSoftwareFailure
alarm.

Description
A critical software failure has occurred.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes may be:
• A critical problem, possibly caused by a software or hardware failure, is detected
by the TPU application

System impact
The GICC is not available. Some calls may be dropped. Network elements may be
dropped and then recovered after a switch to the standby GICC or the recovery of the
active GICC.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, clear any other alarm that has been reported for the same GICC
object
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-267
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_criticalSoftwareFailure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 If the fault is reported periodically by the same GICC, at the OMC-UPS, lock the
GICC object.
...................................................................................................................................................................................................

3 At the RNC, replace the GICC.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-268 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_heartbeatFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_heartbeatFailure alarm.

Description
This fault is raised when a TPU platform heartbeat module has trouble communicating
with either peer instances or the local application.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Process failure on a remote GICC card. Possible causes are:
• The remote GICC card performs a reset
• A GICC reports that it cannot communicate with a CICC
• A CICC reports that it cannot communicate with a GICC.

System impact
A remote GICC card probably performs a reset.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No action required. The error will be cleared automatically after the remote GICC has
been recovered.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-269
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_heartbeatFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-270 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_memoryBlockError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_memoryBlockError
alarm.

Description
Possible indications of high Message Block Chain (MBC) memory loading are
occurring.

Default severity
Major

Alarm type
qualityofServiceAlarm

Root cause
High load distributed to the GICC causing high Message Block Chain memory load.
The high load can be an indication that the RNC is at its capacity or is nearing its
capacity and requires replanning or re-engineering.

System impact
Establishment of new calls may be refused. As long as the memory block error is not
cleared, the TPU application (C-plane) does not accept new contexts/calls on that
GICC.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that all GICC cards are unlocked and enabled.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-271
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCProc_memoryBlockError
procedures

...................................................................................................................................................................................................

2 A network replanning may be necessary in case the capacity of the RNC is reached.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-272 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_memoryUsageOverload
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_memoryUsageOverload
alarm.

Description
The processor on the GICC is in memory usage overload.

Default severity
Major

Alarm type
qualityofServiceAlarm

Root cause
The threshold for memory usage overload of the processor on the GICC is exceeded.

System impact
Memory overload may degrade the system performance.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 Contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-273
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_resourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_resourceFailure alarm.

Description
A non-vital resource is unavailable or has been lost.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
Probable causes are
• Underlying resource (GICCBPEthePort) unavailable caused by software or
hardware failure.
• Underlying service Data Management Framework (DMF) unavailable caused by
software or hardware failure.

System impact
GICC not available for call processing.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-274 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_resourceFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, lock the GICC object


...................................................................................................................................................................................................

3 At the RNC, replace the GICC.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-275
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_restoreServiceFailure
alarm.

Description
Request to restore service of the Gateway Intelligent Carrier Card (GICC) Processor
has failed
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
GICC processor not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.

...................................................................................................................................................................................................................................
16-276 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_restoreServiceFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-277
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_softwareAssertError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_softwareAssertError
alarm.

Description
A software assertion error has occurred.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
An invalid condition is detected by the TPU application.

System impact
The GICC is not available. Some calls may be dropped. Network elements may be
dropped and then recovered after a switch to the standby GICC or the recovery of the
active GICC.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, perform a reset of the GICC object to reboot the GICC.
...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.

...................................................................................................................................................................................................................................
16-278 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_softwareAssertError
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-279
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_softwareVersionMismatch
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_softwareVersionMismatch
alarm.

Description
The software version running on this processor does not match the provisioned
software version.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
A software installation failed or has not initiated.

System impact
Processor may not initialize properly.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Install the provisioned software version on the processor.

...................................................................................................................................................................................................................................
16-280 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_softwareVersionMismatch
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-281
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_standbyMateDown
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_standbyMateDown alarm.

Description
Standby services on the associated mate Gateway Intelligent Carrier Card (GICC) may
be unavailable or degraded.
This alarm indicates that one of three conditions likely occurred:
1. All optical links on the mated GICC are failed or unavailable.
An indication that this may have occurred would be individual alarms on each of
the 4 OC3 ports on the other GICC, as well as an ’allOpticalLinksFailed’ alarm on
the other GICCProc.
2. The processor or card itself on the associated mated GICC may have failed.
An indication that this may have occurred would be one or more alarms on the
other GICC or GICCProc.
3. The GICCProc upon which this alarm was raised has lost communication with it’s
associated mated GICCProc. The other GICCProc may be fully operational or
failed in this case, however since the local GICCProc cannot heartbeat with it’s
standby mate GICCProc this alarm will be raised.
If no individual alarms are seen on the associated mate GICC or GICCProc then
this may be a communication problem and the standby services may very well be
still available, though it is highly advisable to troubleshoot this issue to the point
where this alarm becomes cleared.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Optical ATM link failure or ethernet fabric failure.

System impact
No redundant GICC processor available.

Automatic corrective actions


None
...................................................................................................................................................................................................................................
16-282 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_standbyMateDown
procedures

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, check the status of the OC3 ports on the associated mate GICC. If
all 4 OC3 ports are alarmed and / or failed then this ’standbyMateDown’ will be raised
on the local GICCProc. Check also for an ’allOpticalLinksFailed’ alarm on the mated
GICCProc. This can also cause the current alarm This implies that no standby OC3
ports are available if one of the local ports fail.
Check the PSAX and network to see if the port failure is external. If no external cause
can be found proceed to step 2.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the status of the associated mate GICC processor and the
mate GICC board itself. Also check if the mated GICC is locked. Check for alarms or
states that indicate problems with the board or processor and replace if necessary. If no
problem can be found on the mate board or processor proceed to step 3.
...................................................................................................................................................................................................

3 At the OMC-UPS, check the status of local RNC communications, - e.g. look for ESC
and EthernetPort alarms that might effect GICC communications. If no local
communications problem can be found proceed to step 4.
...................................................................................................................................................................................................

4 At the OMC-UPS, reset the standby GICC.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-283
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCProc_vitalResourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCProc_vitalResourceFailure
alarm.

Description
A vital resource is unavailable or is out of service.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Underlying resource (GICCBPEthePort) unavailable caused by software or
hardware failure.
• Underlying service Data Management Framework (DMF) unavailable caused by
software or hardware failure.

System impact
GICC not available for call processing. Calls hosted on the card or context that are
hosted on that card are dropped.

Failed processor System impact


Active SP All calls are dropped
Standby SP No impact
TP All calls hosted on that card are dropped.
Calls related to the NodeB context (NBAP/ALCAP) or
cell contexts (common control channels) hosted on the
card are dropped.
CP Calls related to any context controlled by the card are
dropped.

...................................................................................................................................................................................................................................
16-284 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance GICCProc_vitalResourceFailure
procedures

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, lock the GICC object


...................................................................................................................................................................................................

3 At the RNC, replace the GICC.


...................................................................................................................................................................................................

4 At the OMC-UPS, unlock the GICC object.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-285
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the GICC STM1/OC3 port.

Contents

GICCSTM1OC3Port_linkFailure 16-287
GICCSTM1OC3Port_linkFailureAIS_L 16-289
GICCSTM1OC3Port_linkFailureAIS_P 16-291
GICCSTM1OC3Port_linkFailureLCD_P 16-293
GICCSTM1OC3Port_linkFailureLOF 16-295
GICCSTM1OC3Port_linkFailureLOP_P 16-297
GICCSTM1OC3Port_linkFailureLOS 16-299
GICCSTM1OC3Port_linkFailurePLM_P 16-301
GICCSTM1OC3Port_linkFailureRDI_L 16-303
GICCSTM1OC3Port_linkFailureRDI_P 16-305
GICCSTM1OC3Port_restoreServiceFailure 16-307

...................................................................................................................................................................................................................................
16-286 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCSTM1OC3Port_linkFailure
alarm.

Description
A failure has occurred on the ATM (STM1/OC3) link connection.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
ATM link connection failure

System impact
During the switch over to the standby GICC some packets may be lost. If the standby
GICC is not available the connection to the network will be lost and calls will fail.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the ATM link connection

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-287
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-288 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureAIS_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureAIS_L alarm.

Description
An Alarm Indication Signal - Line (AIS-L) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
An AIS-L is an indication that the far end is out of service.
An AIS-L is sent by an Section Terminating Equipment (STE) to a downstream Line
Terminating Equipment (LTE) when LOS or LOF is detected on an incoming SONET
section.

System impact
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-289
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureAIS_L
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-290 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureAIS_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureAIS_P alarm.

Description
An Alarm Indication Signal - Path (AIS-P) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
An AIS-P is an indication that the far end is out of service.
An AIS-P is sent by an Line Terminating Equipment (LTE) to a downstream Path
Terminating Equipment (PTE) when an LOS or LOF is detected on a upstream
SONET section.

System impact
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.
Loss of communication at the remote end of the optical link.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-291
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureAIS_P
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the far end, check the physical ATM link connection. Correct problem found at the
far end.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-292 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureLCD_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureLCD_P alarm.

Description
An Loss of Cell Delineation - Path (LCD-P) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
The ATM cell alignment boundary in an octet stream can not be maintained.
Possible causes are:
• Physical problem with the ATM link connection.

System impact
Loss of communication.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-293
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureLCD_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-294 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureLOF
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCSTM1OC3Port_linkFailureLOF
alarm.

Description
An Loss Of Frame (LOF) has occurred on the ATM (STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
A signal could not be detected at the interface. The cause of the problem can be at the
RNC or at the far end of the connection. Both sides must be checked.
Probable causes are:
• The link is not plugged in
• The connector is damaged
• The fiber is damaged
• The fiber is cut.

System impact
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-295
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureLOF
procedures

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the far end, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-296 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureLOP_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureLOP_P alarm.

Description
An Loss of Pointer Path (LOP-P) failure has occurred on the ATM (STM1/OC3) link
connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
A valid pointer on an incoming signal can not be located.
A possible provisioning problem.

System impact
Payload can not be extracted from messages.
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the ATM link provisioning data.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-297
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureLOP_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-298 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureLOS
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the GICCSTM1OC3Port_linkFailureLOS
alarm.

Description
An Loss of Signal (LOS) failure has occurred on the ATM (STM1/OC3) link
connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Physical problem with the ATM link connection.

System impact
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-299
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureLOS
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-300 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailurePLM_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailurePLM_P alarm.

Description
A Payload-Label-Mismatch-Path (PLM-P) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
The incoming payload label does not match the expected payload label. The label is
corrupted.

System impact
During the switch over some packets may be lost. If the protection line is not
available, the connection to the network will be lost and calls will fail.

Automatic corrective actions


When the working STM-1/OC-3 line fails, traffic shall be is automatically switched to
the protection STM-1/OC-3 line.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-301
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailurePLM_P
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-302 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureRDI_L
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureRDI_L alarm.

Description
A Remote Defect Indication Line (RDI-L) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
A problem at the remote end of the line segment.
An RDI-L is sent upstream to a peer Line Terminating Equipment (LTE) when an
AIS-L alarm or low-level defects are detected.

System impact
The link has a problem at the remote end of the line segment.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-303
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureRDI_L
procedures

...................................................................................................................................................................................................

2 Correct failures at the remote end.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-304 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_linkFailureRDI_P
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_linkFailureRDI_P alarm.

Description
A Remote Defect Indication Path (RDI-P) failure has occurred on the ATM
(STM1/OC3) link connection.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
An RDI-P is an indication of a problem at the remote end of the line segment.
An RDI-P is sent upstream to a peer Path Terminating Equipement (PTE) when a
defect in the signal, typically an AIS-P, is detected.

System impact
The link has a problem at the remote end of the line segment.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the RNC, check the physical ATM link connection.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-305
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_linkFailureRDI_P
procedures

...................................................................................................................................................................................................

2 At the far end, check the physical ATM link connection. Correct problem found at the
far end.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-306 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

GICCSTM1OC3Port_restoreServiceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the
GICCSTM1OC3Port_restoreServiceFailure alarm.

Description
Request to restore service of the Gateway Intelligent Carrier Card (GICC) Processor
has failed

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Maintenance action could not be performed due to underlying software failure.

System impact
GICC processor not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, reset the GICC object.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-307
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance GICCSTM1OC3Port_restoreServiceFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-308 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

HSDPA alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for HSDPA alarms

Contents

HSDPA_degraded 16-310
HSDPA_failed 16-312
HSDPA_hSDPAOCNSchannelSetupFailure 16-314
HSDPA_notInstalled 16-316

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-309
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

HSDPA_degraded
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the HSDPA_degraded alarm.

Description
CRNC detects that the HSDPA object has transitioned to the enabled/degraded state.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
A Service Impacting NBAP RSI message was received from the NodeB which
indicates that the HSDPA resources were degraded. HSDPA calls are still possible, but
the full quota of HSDPA calls is not possible until the problem is fixed.

System impact
HSDPA calls can be made on the affected cell but the number of such calls will be
restricted by the faulty equipment, non-HSDPA calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms from the NodeB, take corrective actions to resolve
hardware failures, which affect the functioning of a cell.

...................................................................................................................................................................................................................................
16-310 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance HSDPA_degraded
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-311
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

HSDPA_failed
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the HSDPA_failed alarm.

Description
CRNC detects that the HSDPA object has transitioned to the disabled/failed state.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
A hardware failure at the NodeB which resulted in a change in the HSDPA capability
of the cell has been communicated to the CRNC via the Cell Information HS-DSCH
Resources Information element in the Service Impacting NBAP RSI message.

System impact
HSDPA calls cannot be made on the affected cell, non-HSDPA calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for alarms from the NodeB, take corrective actions to resolve
hardware failures, which affect the functioning of a cell.
If the HSDPA fault cannot be rectified immediately, it is recommended to delete the
HSDPA managed object so that channelisation codes will be available for R99 calls.

...................................................................................................................................................................................................................................
16-312 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance HSDPA_failed
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-313
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

HSDPA_hSDPAOCNSchannelSetupFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the HSDPA_hSDPAOCNSchannelSetup-
Failure alarm.

Description
OCNS-HSDPA setup has been failed.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
HSDPA resources unavailable in the LCell.

System impact
OCNS-HSDPA service unavailable.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, ensure OCNSHSDPA resources are available in the LCell.


...................................................................................................................................................................................................

2 At the OMC-UPS, delete and grow the OCNSHSDPA MO.

...................................................................................................................................................................................................................................
16-314 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance HSDPA_hSDPAOCNSchannelSetupFailure
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-315
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

HSDPA_notInstalled
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the HSDPA_notInstalled alarm.

Description
CRNC detects that it was not possible to set up HSDPA services in the cell.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
A request to configure HSDPA resources in the cell has failed. This failure can be due
to any of the following reasons:
• HSDPA functionality is switched off at the RNC level.
The NodeB does not support HSDPA services.
• The RNC is unable to reserve the channelization codes required for HSDPA.
• A Physical Shared Channel Reconfiguration Failure message or no response was
received from the NodeB in response to a request to configure HSDPA services.
Important! It is recommended to delete the HSDPA managed object as
channelisation codes could have been allocated and they should be freed and made
available for R99 calls.

System impact
HSDPA calls cannot be made on the affected cell, non-HSDPA calls are still possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-316 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance HSDPA_notInstalled
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, Check if both RNC and NodeB supports HSDPA.


...................................................................................................................................................................................................

2 Check maximum transmit power and state of IuB link.


...................................................................................................................................................................................................

3 The HSDPA MO must be deleted and recreated for HSDPA resources to be configured
again.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-317
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Iub interface.

Contents

IuB_cellReconfigTimeout 16-319
IuB_cellSetupTimeout 16-321
IuB_channelReconfigFailure 16-323
IuB_channelReconfigTimeout 16-325
IuB_channelSetupFailure 16-327
IuB_channelSetupTimeout 16-329
IuB_highBER 16-331
IuB_nBAP_Reset_Requ_CCP_Fail 16-333
IuB_nBAP_Reset_Requ_Fail 16-335
IuB_nodeBCommunicationLost 16-337
IuB_parameterFailure 16-340
IuB_resourceFailure 16-342
IuB_sAALUNI_RES_PROT_STA_DN 16-344
IuB_sAALUNI_VCC_ST_DN 16-346
IuB_uNIStack_FAIL 16-348

...................................................................................................................................................................................................................................
16-318 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_cellReconfigTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_cellReconfigTimeout alarm.

Description
There is a timeout of the NBAP Common transport channel reconfiguration request
procedure initiated by the RNC.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
The cell reconfiguration has failed.

System impact
The new configuration for the cell cannot proceed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the Node B operational state is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the IuB operational state is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-319
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_cellReconfigTimeout
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, if the Cell Reconfiguration Timer value is too short, retry the
reconfiguration by increasing the value of the Cell Reconfiguration Timer.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-320 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_cellSetupTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_cellSetupTimeout alarm.

Description
There is a timeout of the NBAP Cell Setup Request procedure initiated by the RNC.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Cell Setup timeout. The cell setup procedure may fail and result in the LCell
uncommissioned for call processing. Failures for this have occurred when the ATM
network drops packets resulting in the far end Node B not receiving all packets
associated with this message.

System impact
The Cell initialization has failed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the Cell Setup Request Timer value is not too short.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the Node B operational state is OK.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-321
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_cellSetupTimeout
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

3 At the OMC-UPS, make sure that the IuB operational state is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, lock and unlock the LNodeB object.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 Correct any communications problem associated with the NBAP link.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-322 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_channelReconfigFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_channelReconfigFailure alarm.

Description
The NBAP procedure “Common Transport Channel Reconfiguration” request initiated
by the RNC has failed for other reasons than a timeout.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
The common channel reconfiguration has failed.

System impact
The new configuration for the common channel cannot proceed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 If... Then...
The cause is ‘Node B resources The logical cell configuration does not match the
not Available’, capability of the local cell. Go to step 2.
The cause is ‘Power level not The logical cell configuration does not match the
supported’, capability of the local cell or power range. Go to
step 3.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-323
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_channelReconfigFailure
procedures

If... Then...
The cause is ‘Hardware Failure’, Go to step 4.

...................................................................................................................................................................................................

2 At the OMC-UPS, check the common channel resources allocation on the LCell object
for the channels stated in the CELL RECONFIGURATION REQUEST message.
...................................................................................................................................................................................................

3 At the OMC-UPS, check the following:


• On the LCell object: the Maximum Transmission Power via the Itf-R
• On the LNodeB object: the Cell Resource, DL Maximum Transmission Capability
attribute.
...................................................................................................................................................................................................

4 At the OMC-UPS, clear any related Node B hardware alarms.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-324 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_channelReconfigTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_channelReconfigTimeout alarm.

Description
There is a timeout of the NBAP Common Transport Channel Reconfiguration request
procedure initiated by the RNC.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
The common channel reconfiguration has failed.

System impact
The new configuration for the common channel cannot proceed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the Node B operational state is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the IuB operational state is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-325
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_channelReconfigTimeout
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, if the Common Transport Channel reconfiguration timer. value is


too short, retry the reconfiguration by increasing the value of the Common Channel
Reconfiguration Timer.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-326 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_channelSetupFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_channelSetupFailure alarm.

Description
There is a failure of the NBAP procedure Common Transport Channel Reconfiguration.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
A Common Channel Setup failure is detected by the Node B. Possible root causes,
indicated in the common channel setup failure cause, are:
• Node B resources not available
• Power level not supported
• Hardware failure.

System impact
The Cell initialization has failed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 If... Then...
The cause is ‘Node B resources The logical cell configuration does not match the
not Available’, capability of the local cell. Go to step 2.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-327
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_channelSetupFailure
procedures

If... Then...
The cause is ‘Power level not The logical cell configuration does not match the
supported’, capability of the local cell or power range. Go to
step 4.
The cause is ‘Hardware Failure’, Go to step 6.

...................................................................................................................................................................................................

2 At the OMC-UPS, check the Common channel resources allocated in the Common
channel Setup Request message. Make sure that the correct logical cell configuration is
being used.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

4 At the OMC-UPS, check the following:


• On the LCELL object: the aggregate DL power of all channels in the cell
• On the LNodeB object, the CellResources DL Maximum Transmission Capability
attribute.
If required, take the appropriate action.
...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


...................................................................................................................................................................................................

6 At the OMC-UPS, check the Node B of concern.


...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-328 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_channelSetupTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_channelSetupTimeout alarm.

Description
There is a timeout of the NBAP Common transport channel setup request procedure
initiated by the RNC.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Setup timeout. The common channel transport procedure may fail and result in the
LCell object being uncommissioned. Failures for this have occurred when ALCAP has
failed to successfully establish common channels on the first traffic channel.

System impact
The Cell initialization has failed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the Node B operational state and the IuB operational
state are OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-329
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_channelSetupTimeout
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the Common transport channel setup request timer.
value is not too short.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, correct the ALCAP transport layer address to align the Node B and
RNC database values.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, correct the ATM transport network to successfully pass the ALCAP
messages required to set up RACH, FACH, PCH.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

5 At the OMC-UPS, correct framing protocol failures which would cause the TPU to fail
in setting up common channels.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-330 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_highBER
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_highBER alarm.

Description
High BER detected on IuB by u & s-plane.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
This alarm is reported as a result of high BER on the IuB link between NodeB &
RNC. Possible causes are:
• Bad connection on E1/T1.
• Faults in the transport network.
• Poor quality of the transmission link

System impact
Excessive link layer retransmission resulting in a significant decrease in user
throughput.
Degrading the capacity of the IuB link.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-331
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_highBER
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, look at the NodeB alarms for BER.


...................................................................................................................................................................................................

2 Check the quality of the transport network.


...................................................................................................................................................................................................

3 Check the BER on E1/T1.


...................................................................................................................................................................................................

4 Fix the transmission problem, if any.


...................................................................................................................................................................................................

5 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-332 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_nBAP_Reset_Requ_CCP_Fail
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_nBAP_Reset_Requ_CCP_Fail
alarm.

Description
NBAP Reset Request for one or more CCPs failed.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
NBAP Reset Request for one or more CCPs failed.

System impact
Cannot guarantee that Node B has released all resources within a Node B subsystem
associated with previous calls. Risk for some hanging resources to remain in Node B
reducing efficiency.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the Iub transmission link is OK.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-333
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_nBAP_Reset_Requ_CCP_Fail
procedures

If necessary, at the RNC, invoke a reset action of the affected interface.


...................................................................................................................................................................................................

3 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-334 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_nBAP_Reset_Requ_Fail
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_nBAP_Reset_Requ_Fail alarm.

Description
NBAP Reset Request for entire Node B failed.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
NBAP Reset Request for entire Node B failed.

System impact
Cannot guarantee that Node B has released all resources associated with previous calls.
Risk for some hanging resources to remain in NodeB reducing efficiency.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, check the Iub transmission link.


If necessary, at the RNC, invoke a reset action of the affected interface.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-335
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_nBAP_Reset_Requ_Fail
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-336 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuB_nodeBCommunicationLost
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_nodeBCommunicationLost
alarm.

Description
Communication to the Node B is lost.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• Hardware problems
• Link failure
• Communication software failure on the Node B or the RNC.

System impact
Loss of service to the Node B.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-337
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuB_nodeBCommunicationLost
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the following:

If... Then...
Only one IubCommunicationLost Go to step 2.
alarm is active,
More IubCommunicationLost Go to step 5.
alarms are active,

...................................................................................................................................................................................................

2 At the OMC-UPS, clear any URC or E1T1Port alarms that can cause this problem.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, clear any other alarms that can cause this problem.
Hardware failures for the Node B would result in other errors for the Node B
Controller logs indicating where the action takes place.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

4 At the OMC-UPS, check whether GICCSTM1OC3Port alarms indicate the possible


source of this problem and take the appropriate action
If the problem persists, go to step 6.
...................................................................................................................................................................................................

5 At the OMC-UPS, clear any ICC alarms that can cause this problem.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

6 At the OMC-UPS, perform a reset type 2 to reinitialize the RNC.


Important! Reinitializing the RNC will affect ALL Node Bs that are connected to
this RNC!

....................................................................................................................................................................................................................................
16-338 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_nodeBCommunicationLost
procedures

...................................................................................................................................................................................................

7 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-339
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB_parameterFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_parameterFailure alarm.

Description
Orthogonal Channel Noise Simulator (OCNS) Channel failure due to incorrect input
parameters.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
communicationsAlarm

Root cause
This fault is due to incorrect input parameters for setting up the OCNS.
Note: The Distinguished Name (DN) of the OCNS channel for which incorrect
parameters have been entered, is listed in the alarm text.

System impact
OCNS testing is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the OCNS input parameters. The cell id or channel id could
be wrong. Make sure that the values are in the recommended range.

...................................................................................................................................................................................................................................
16-340 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_parameterFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-341
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB_resourceFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_resourceFailure alarm.

Description
Orthogonal Channel Noise Simulator (OCNS) Channel failure due to unavailable
resources.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
qualityofServiceAlarm

Root cause
OCNS Resource failure could be due to insufficient power available to set up OCNS
channels on a particular cell, or Node B resources are not available.
Note: The Distinguished Name (DN) of the OCNS channel for which the resource
setup failed, is listed in the alarm text.

System impact
OCNS testing is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check the input power setting for each of the OCNS channels.
Make sure that the total power for OCNS channels does not exceed the recommended
value.
...................................................................................................................................................................................................................................
16-342 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_resourceFailure
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-343
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB_sAALUNI_RES_PROT_STA_DN
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_sAALUNI_RES_PROT_S-
TA_DN alarm.

Description
The Signaling ATM Adaptation Layer -User Network Interface (SAAL-UNI) assured
link is down.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Communication failure.

System impact
Loss of service on the link

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the link and the configuration of the link.


When the link is up the alarm will be cleared.

...................................................................................................................................................................................................................................
16-344 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_sAALUNI_RES_PROT_STA_DN
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-345
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB_sAALUNI_VCC_ST_DN
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_sAALUNI_VCC_ST_DN alarm.

Description
The Signaling ATM Adaptation Layer - User Network Interface (SAAL-UNI) virtual
channel connection is down.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Virtual channel failure.

System impact
No virtual channel available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check the link and the link configuration.


When the link is up the alarm will be cleared.

...................................................................................................................................................................................................................................
16-346 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_sAALUNI_VCC_ST_DN
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-347
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuB_uNIStack_FAIL
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuB_uNIStack_FAIL alarm.

Description
General User-Network Interface (UNI) stack error.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Task suspended
• Task dead
• General configuration error
• Layer manager failure.

System impact
Signaling link is temporarily not available.

Automatic corrective actions


The UNI stack will restore automatically or re-initialize on another Traffic Processor
(TP) Signaling Processor (SP) is reset.

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 No action required.
The signaling link restores automatically and the alarm clears automatically.

...................................................................................................................................................................................................................................
16-348 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuB_uNIStack_FAIL
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-349
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuCS alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Iu-cs interface.

Contents

IuCS_coreNetwork_OOS_For_NonUE_Sig 16-351
IuCS_rANAPResetFail 16-353
IuCS_remoteSubsystemOutOfService 16-355
IuCS_sNE_Context_Cre_Fail_For_NonUE_Sig 16-357

...................................................................................................................................................................................................................................
16-350 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuCS_coreNetwork_OOS_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuCS_coreNetwork_OOS_For_Non-
UE_Sig alarm.

Description
Remote core network out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The circuit switched core network has an ‘out of service’ service state. The RNC is
unable to communicate with the circuit switched core network.

System impact
Communication is suspended over connection-oriented or connectionless Iu-CS
channels. Circuit switched services including voice are not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Contact circuit switch MSC maintenance personnel to determine the cause of the
‘out-of-service’ core network and take the appropriate action.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-351
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuCS_coreNetwork_OOS_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-352 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuCS_rANAPResetFail
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuCS_rANAPResetFail alarm.

Description
RANAP reset procedure towards the 3G-MSC failed.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
RANAP reset procedure towards the 3G-MSC failed.

System impact
Cannot guarantee that 3G-MSC has released all resources associated with the RNC that
had previously been allocated to support calls. Potential risk for some hanging
resources to remain in 3G-MSC reducing efficiency.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the 3G-MSC operational state and the Iu-cs
transmission link are OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, perform a reset type 2 on the IuCS object. This will trigger a
RANAP reset procedure.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-353
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuCS_rANAPResetFail
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-354 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuCS_remoteSubsystemOutOfService
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuCS_remoteSubsystemOutOfService
alarm.

Description
The remote subsystem has gone out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Remote SCCP subsystem being out of service
• Remote SCCP stack being not available
• MTP3 connection failure (indicated by the SS7_MTP3_PAUSE alarm).

System impact
Existing circuit switched calls are dropped. New circuit switched calls are refused.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, if ″SS7_MTP3_PAUSE″ is pending, react on this one.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-355
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuCS_remoteSubsystemOutOfService
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the state of the remote NE.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-356 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuCS_sNE_Context_Cre_Fail_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuCS_sNE_Context_Cre_Fail_For-
_NonUE_Sig alarm.

Description
IuCS Sub Network Element Connectionless Context Create Failure.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• No GICC available for call processing
• Failure to create ATM resources (AAL2 PVCs)
• Unavailability of the Broadband SS7 stack (possibly caused by a GICC failure or a
signaling stack failure).

System impact
The shelf is not available for call processing. No calls are possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm.
...................................................................................................................................................................................................

1 At the OMC-UPS, unlock the GICC objects.


Note: It is recommended to have the GICCs unlocked, since they work in active/active
mode.
...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-357
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuCS_sNE_Context_Cre_Fail_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-358 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuPS alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Iu-ps interface.

Contents

IuPS_coreNetwork_OOS_For_NonUE_Sig 16-360
IuPS_gTP_U_Echo_Responses_Not_Received 16-362
IuPS_rANAPResetFail 16-364
IuPS_remoteSubsystemOutOfService 16-366
IuPS_sNE_Context_Cre_Fail_For_NonUE_Sig 16-368

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-359
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPS_coreNetwork_OOS_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPS_coreNetwork_OOS_For_Non-
UE_Sig alarm.

Description
The remote core network is out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Gateway Intelligent Carrier Cards (GICC) on the RNC are not in an operational
state
• The packet switched core network has an ‘out of service’ service state and the RNC
is unable to communicate with the packet switched core network.

System impact
Communication is suspended over connection-oriented or connectionless Iu-PS
channels. Packet switched services are not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the GICC object is in an operational state
(Unlocked/Enabled).

...................................................................................................................................................................................................................................
16-360 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuPS_coreNetwork_OOS_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 Contact packet switch SGSN maintenance personnel to determine the cause of the
‘out-of-service’ core network.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-361
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPS_gTP_U_Echo_Responses_Not_Received
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPS_gTP_U_Echo_Responses-
_Not_Received alarm.

Description
The RNC did not receive an Echo Response message on the several consecutive Echo
Request messages transmitted by the RNC.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• An SGSN error in the IP protocol stack
• A transport network error
• A change in the configuration of either the transport network, RNC, or SGSN,
while the nodes were in operation.

System impact
The particular GPRS Tunneling Protocol - User plane (GTP-U) instance blocked its
communication with the particular SGSN IP address.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-362 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuPS_gTP_U_Echo_Responses_Not_Received
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Check all the possible causes that created this error and take the appropriate action.
...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.


If the alarm does not reappear, the procedure is completed.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-363
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPS_rANAPResetFail
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPS_rANAPResetFail alarm.

Description
RANAP reset procedure towards the SGSN failed.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
RANAP reset procedure towards SGSN failed.

System impact
Cannot guarantee that SGSN has released all resources associated with RNC that had
previously been allocated to support calls. Potential risk for some hanging resources to
remain in SGSN reducing efficiency.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the SGSN operational state and the Iu-ps
transmission link are OK.
...................................................................................................................................................................................................

2 At the OMC-UPS, perform a reset type 2 on the IuPS object. This will trigger a
RANAP reset procedure.
...................................................................................................................................................................................................................................
16-364 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuPS_rANAPResetFail
procedures

...................................................................................................................................................................................................

3 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-365
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPS_remoteSubsystemOutOfService
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPS_remoteSubsystemOutOfService
alarm.

Description
The remote subsystem has gone out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Remote SCCP subsystem being out of service
• Remote SCCP stack being not available
• MTP3 connection failure (indicated by the SS7_MTP3_PAUSE alarm).

System impact
Existing packet switched calls are dropped. New packet switched calls are refused.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, if ″SS7_MTP3_PAUSE″ is pending, react on this one.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-366 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuPS_remoteSubsystemOutOfService
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the state of the remote NE.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-367
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPS_sNE_Context_Cre_Fail_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPS_sNE_Context_Cre_Fail_For-
_NonUE_Sig alarm.

Description
IuPS Sub Network Element Connectionless Context Create Failure.

Default severity
Major

Alarm type
processingErrorAlarm

Probable cause
Possible causes are:
• No GICC available for call processing
• Failure to create ATM resources (AAL2 PVCs)
• Unavailability of the Broadband SS7 stack (possibly caused by a GICC failure or a
signaling stack failure).

System impact
The shelf is not available for call processing. No calls are possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, unlock the GICC objects.


Note: It is recommended to have the GICCs unlocked, since they work in active/active
mode.
...................................................................................................................................................................................................................................
16-368 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuPS_sNE_Context_Cre_Fail_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-369
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuPSSubNet alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the IuPSSubNet alarms.

Contents

IuPSSubNet_communicationFailure 16-371

...................................................................................................................................................................................................................................
16-370 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuPSSubNet_communicationFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuPSSubNet_communicationFailure
alarm.

Description
The IuPSSubnet is disabled, all associated Permanent Virtual Circuits (PVCs) have
failed.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• Configuration problem
• The SGSN on the packet core network is down
• A router between the RNC and the SGSN has failed.

System impact
New packet call are not possible

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Ensure that the IuPS link is in service.


If the IuPS link is out of service, procedure is completed.

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-371
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance IuPSSubNet_communicationFailure
procedures

...................................................................................................................................................................................................

2 At the RNC, check that the SGSN IP addresses are correctly configured.
If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

3 Check the status of the SGSN:

If... Then...
If the SGSN is not functional, Go to step 4.
If the SGSN is functional, Go to step 5.

...................................................................................................................................................................................................

4 At the OMC-UPS, wait until the SGSN recovers.


If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

5 Check the status of PVCs on any routers between the RNC and the SGSN.
If the alarm is cleared, procedure is completed.
...................................................................................................................................................................................................

6 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
16-372 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

IuR alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the Iur interface.

Contents

IuR_pRNC_OOS_For_NonUE_Sig 16-374
IuR_remoteSubsystemOutOfService 16-376
IuR_sNE_Context_Cre_Fail_For_NonUE_Sig 16-378

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-373
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuR_pRNC_OOS_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuR_pRNC_OOS_For_NonUE_Sig
alarm.

Description
The peer RNC is out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Communication link to the peer RNC is down
• Local RNC Iur link or other component problem
• Peer RNC Iur link or other component problem.

System impact
Communication is suspended over connection-oriented or connectionless Iur channels.
The serving RNC is not able to establish resources for radio link setup on the peer
RNC.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the communications link to the peer RNC is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................................................
16-374 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuR_pRNC_OOS_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, make sure that the Iur and parent components on the local and the
peer RNCs are unlocked and enabled.
...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-375
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuR_remoteSubsystemOutOfService
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuR_remoteSubsystemOutOfService
alarm.

Description
The remote subsystem has gone out of service.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
Possible causes are:
• Remote SCCP subsystem being out of service
• Remote SCCP stack being not available
• MTP3 connection failure (indicated by the SS7_MTP3_PAUSE alarm).

System impact
Existing packet switched calls are dropped. New packet switched calls are refused.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, if ″SS7_MTP3_PAUSE″ is pending, react on this one.


If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-376 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuR_remoteSubsystemOutOfService
procedures

...................................................................................................................................................................................................

2 At the OMC-UPS, check the state of the remote NE.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-377
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

IuR_sNE_Context_Cre_Fail_For_NonUE_Sig
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the IuR_sNE_Context_Cre_Fail_For-
_NonUE_Sig alarm.

Description
IuR Sub Network Element Connectionless Context Create Failure.

Default severity
Major

Alarm type
processingErrorAlarm

Probable cause
Possible causes are:
• No GICC available for call processing
• Failure to create ATM resources (AAL2 PVCs)
• Unavailability of the Broadband SS7 stack (possibly caused by a GICC failure or a
signaling stack failure).

System impact
The shelf is unavailable for call processing. No calls are possible.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, unlock the GICC objects.


Note: It is recommended to have the GICCs unlocked, since they work in active/active
mode.
...................................................................................................................................................................................................................................
16-378 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance IuR_sNE_Context_Cre_Fail_For_NonUE_Sig
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-379
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell alarms

Overview
...................................................................................................................................................................................................................................

Purpose
This section describes the fault clearance procedures for the LCell.

Contents

LCell_avail_Status_Degraded 16-381
LCell_bCCHScheduleErr 16-382
LCell_callPreemptionError 16-384
LCell_callPreemptionFailure 16-386
LCell_channelSetupFailure 16-388
LCell_code_Allocation_Failure 16-390
LCell_code_Starvation 16-392
LCell_common_Transport_Channel_Reconfiguration_Failure 16-394
LCell_common_Transport_Channel_Reconfiguration_Timeout 16-396
LCell_common_Transport_Channel_Setup_Failure 16-398
LCell_common_Transport_Channel_Setup_Timeout 16-400
LCell_configurationError 16-402
LCell_configurationErrorSCCPCH 16-404
LCell_nodeBUnavailable 16-406
LCell_rRC_Connection_Establish_Failure 16-408
LCell_reconfigFailure 16-410
LCell_reconfigTimeout 16-412
LCell_setupFailure 16-414
LCell_setupTimeout 16-416
LCell_system_Information_Update_Failure 16-418
LCell_tPUCellContextFailure 16-420

...................................................................................................................................................................................................................................
16-380 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures

LCell_avail_Status_Degraded
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_avail_Status_Degraded alarm.

Description
The availability status of the cell is degraded.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
The NodeB have indicated that the power capability of the cell has been degraded or
there has been some other RNC initiated degradation of the cell.

System impact
Depending on the root cause of the cell degradation, call processing may be impacted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Locate the root cause of the cell degradation and take appropriate action.
...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-381
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_bCCHScheduleErr
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_bCCHScheduleErr alarm.

Description
CRNC detects that the BCCH schedule is invalid.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
System Information Blocks (SIB) scheduling parameters are incorrect.

System impact
The scheduling error is due to an attempt by the operator to apply an invalid SIB REP
of any SIB Type. The CRNC calculates the new BCCH schedule with the new SIB
REP and found that it resulted in overlapping SIBs.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, use the default value of the SIB REP of the SIB Type (if available).
...................................................................................................................................................................................................

2 Apply the previous value of the SIB REP of the SIB Type (if any).

...................................................................................................................................................................................................................................
16-382 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_bCCHScheduleErr
procedures

...................................................................................................................................................................................................

3 Change the SIB REP of the SIB Type in consultation with Alcatel-Lucent customer
support.
...................................................................................................................................................................................................

4 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-383
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_callPreemptionError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_callPreemptionError alarm.

Description
The RNC has preempted the wrong class of call types. Code starvation has occurred
and there are no free channelisation codes for a new emergency call request.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Software error. The RNC pre-empted a wrong type of call (e.g. control channels or
existing emergency calls). This means that the wrong class of calls were pre-empted in
the event of code starvation and a request for an emergency call.

System impact
Existing call(s) may be dropped, the new emergency call may not be allowed.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, manually clear the alarm.

...................................................................................................................................................................................................................................
16-384 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_callPreemptionError
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-385
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_callPreemptionFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_callPreemptionFailure alarm.

Description
The RNC has failed to to preempt existing calls to accommodate a request for a new
emergency call. Code starvation has occurred and there are no free channelisation
codes for a new emergency call request.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
processingErrorAlarm

Root cause
Software error. The RNC pre-empted a wrong type of call (e.g. control channels or
existing emergency calls). This means that the wrong class of calls were pre-empted in
the event of code starvation and a request for an emergency call.

System impact
Emergency calls will not be accepted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following step to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, manually clear the alarm.

...................................................................................................................................................................................................................................
16-386 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_callPreemptionFailure
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-387
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_channelSetupFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_channelSetupFailure alarm.

Description
Orthogonal Channel Noise Simulator (OCNS) Channel Setup Failure.
Important! This alarm must be cleared manually.

Default severity
Minor

Alarm type
equipmentAlarm

Root cause
The OCNS should be run during the provisioning of the system. Possible causes are:
• No DL Channelisation codes in this cell are available
• Too many engineers are working on the provisioning system
• Problem with the resource allocation in the system
• Hardware failure or break of Iub link.
Note: The Distinguished Name (DN) of the OCNS channel for which the setup failed,
is listed in the alarm text.

System impact
OCNS testing is not available.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-388 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_channelSetupFailure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, delete the OCNS for that specific cell.


...................................................................................................................................................................................................

2 Check how many CEs have been occupied. If all CEs have been occupied, this means
that too many people are using the system now. Else go to step 3.
...................................................................................................................................................................................................

3 If a CE is still available, then try to set up the OCNS once more.


...................................................................................................................................................................................................

4 At the OMC-UPS, manually clear the alarm.


...................................................................................................................................................................................................

5 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-389
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_code_Allocation_Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_code_Allocation_Failure
alarm.

Description
Channelisation code allocation failure per sector-carrier. Codes are not allocated.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Probable causes are:
• Software error
• Database inconsistency
• Corrupt data.

System impact
Cannot accommodate new users requiring new channelisation code.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, manually clear the alarm.

...................................................................................................................................................................................................................................
16-390 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_code_Allocation_Failure
procedures

...................................................................................................................................................................................................

2 Pass on the information to the RF engineer for analysis.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-391
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_code_Starvation
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_code_Starvation alarm.

Description
Channelisation code starvation detected (no codes are available) per sector-carrier.

Default severity
Major

Alarm type
qualityofServiceAlarm

Root cause
Probable causes are:
• Congestion
• Resource is at or nearing capacity
• System resources overload.

System impact
Cannot accommodate new users requiring new channelisation code.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 Resize the cell.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 Increase the capacity of the cell by adding more hardware.


...................................................................................................................................................................................................................................
16-392 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_code_Starvation
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-393
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_common_Transport_Channel_Reconfiguration_Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_common_Transport_Channel-
_Reconfiguration_Failure alarm.

Description
The Common Transport Channel reconfiguration has failed.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
Probable causes are:
• Unknown cell identified
• Insufficient physical channel resources
• Node B resources unavailable
• DL radio resources not available
• UL radio resources not available
• Insufficient physical channel resources
• Requested configuration not supported.

System impact
Possible system impact may be:
• The transport channel has not been resized
• The call capacity of the cell has not been adjusted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-394 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures LCell_common_Transport_Channel_Reconfiguration_Failure

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 Check the root cause and take the appropriate action.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-395
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_common_Transport_Channel_Reconfiguration_Timeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_common_Transport_Channel-
_Reconfiguration_Timeout alarm.

Description
The Common Transport Channel reconfiguration timer has expired.

Default severity
Critical

Alarm type
communicationsAlarm

Root cause
Probable causes are:
• The timer is set too short
• The Node B is malfunctioning.

System impact
Possible system impact may be:
• The transport channel has not been resized
• The call capacity of the cell has not been adjusted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-396 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance
procedures LCell_common_Transport_Channel_Reconfiguration_Timeout

...................................................................................................................................................................................................

2 At the Node B, increase the timer setting.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-397
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_common_Transport_Channel_Setup_Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_common_Transport_Chan-
nel_Setup_Failure alarm.

Description
The setup of the Common Transport Channel has failed.

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Probable causes are:
• Unknown cell identified
• Insufficient physical channel resources
• Node B resources unavailable
• DL radio resources not available
• UL radio resources not available
• Insufficient physical channel resources
• Requested configuration not supported.

System impact
Possible system impact may be:
• The transport channel has not been setup
• The call capacity of the cell has not been created.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-398 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_common_Transport_Channel_Setup_Failure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 Check the root cause and take the appropriate action.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-399
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_common_Transport_Channel_Setup_Timeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_common_Transport_Chan-
nel_Setup_Timeout alarm.

Description
The Common Transport Channel setup timer has expired.

Default severity
Warning

Alarm type
communicationsAlarm

Root cause
Probable causes are:
• The timer is set too short
• The Node B is malfunctioning.

System impact
Possible system impact may be:
• The transport channel has not been setup
• The call capacity of the cell has not been created.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-400 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_common_Transport_Channel_Setup_Timeout
procedures

...................................................................................................................................................................................................

2 At the Node B, increase the timer setting.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-401
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_configurationError
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_configurationError alarm.

Description
Configuration error.
Important! This alarm must be cleared manually.

Default severity
Critical

Alarm type
processingErrorAlarm

Root cause
The Node B fails to update System Information Blocks (SIBs).

System impact
SIBs cannot be updated in a cell. UEs cannot access the radio network correctly.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check for Node B alarms.


If necessary, lock, reset and unlock the LNodeB object.
...................................................................................................................................................................................................

2 At the OMC-UPS, manually clear the alarm.

...................................................................................................................................................................................................................................
16-402 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_configurationError
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-403
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_configurationErrorSCCPCH
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_configurationErrorSCCPCH
alarm.

Description
The FACH service profile for one or more cells has been configured with data
incompatible with the software release.
Important! This alarm must be cleared manually.

Default severity
Major

Alarm type
processingErrorAlarm

Root cause
Incorrect FACH service profile configuration. The profile requires one data and one
signalling FACH.

System impact
Cells with incorrect configuration will not transmit.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, check OAM configuration for the FACH service profile.

...................................................................................................................................................................................................................................
16-404 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_configurationErrorSCCPCH
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-405
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_nodeBUnavailable
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_nodeBUnavailable alarm.

Description
The cell is not operational due to a Node B block.

Default severity
Major

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Node B is blocked
• Node B is currently being reset.

System impact
No calls are possible on the cell.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the Node B operational state is OK.

...................................................................................................................................................................................................................................
16-406 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_nodeBUnavailable
procedures

...................................................................................................................................................................................................

2 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-407
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_rRC_Connection_Establish_Failure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_rRC_Connection_Establish-
_Failure alarm.

Description
Failure to establish a RRC connection.

Default severity
Major

Alarm type
communicationsAlarm

Root cause
Probable causes are:
• NBAP/RNSAP radio link setup failure including time-out
• ALCAP NBAP/RNSAP data transport bearer setup failure including time-out
• Data transport bearer synchronization failure
• SRNC fails to receive RRC CONNECTION SETUP COMPLETE message
• RESET message in RRC connection establish.

System impact
Possible system impact may be:
• Call setup delay
• Failure to establish a call.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

...................................................................................................................................................................................................................................
16-408 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_rRC_Connection_Establish_Failure
procedures

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the Node B, make sure that the radio interfaces are operational.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 Investigate the transport network and solve any problems.


If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

3 At the OMC-UPS, make sure that the RRC configuration parameters are OK.
...................................................................................................................................................................................................

4 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-409
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_reconfigFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_reconfigFailure alarm.

Description
Logical cell reconfiguration failed.

Default severity
Warning

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Unknown cell identified
• Insufficient physical channel resources
• Node B resources unavailable
• Power level not supported.

System impact
Possible system impact may be:
• The cell has not been reconfigured
• The call capacity of the cell has not been adjusted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.

...................................................................................................................................................................................................................................
16-410 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_reconfigFailure
procedures

If the alarm is cleared, the procedure is completed.


...................................................................................................................................................................................................

2 Check the root cause and take the appropriate action.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-411
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_reconfigTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_reconfigTimeout alarm.

Description
The logical cell reconfiguration timer has expired.

Default severity
Warning

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• The timer is set too short
• The Node B is malfunctioning.

System impact
Possible system impact may be:
• The cell has not been reconfigured
• The call capacity of the cell has not been adjusted.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-412 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_reconfigTimeout
procedures

...................................................................................................................................................................................................

2 At the Node B, increase the timer setting.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-413
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_setupFailure
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_setupFailure alarm.

Description
The cell setup has failed. !!!!!!!!!!!

Default severity
Critical

Alarm type
equipmentAlarm

Root cause
Possible causes are:
• Unknown cell identified
• Insufficient physical channel resources
• Node B resources unavailable
• Power level not supported.

System impact
The new cell has not been added.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.

...................................................................................................................................................................................................................................
16-414 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_setupFailure
procedures

...................................................................................................................................................................................................

2 Check the root cause and take the appropriate action.


...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

....................................................................................................................................................................................................................................
401-382-290R04.03 Alcatel-Lucent - Proprietary 16-415
Issue 1, August 2007 See notice on first page
Corrective maintenance - RNC alarm clearance
procedures

LCell_setupTimeout
...................................................................................................................................................................................................................................

Purpose
This topic provides the procedure for clearing the LCell_setupTimeout alarm.

Description
The cell setup time expired.

Default severity
Warning

Alarm type
communicationsAlarm

Root cause
Possible causes are:
• The timer is set too short
• The Node B is malfunctioning.

System impact
The new cell has not been added.

Automatic corrective actions


None

Before you begin


No additional information is required before you begin this procedure.

Manual corrective actions


Perform the following steps to clear the alarm:
...................................................................................................................................................................................................

1 At the OMC-UPS, make sure that the operational state of the Node B is OK.
If the alarm is cleared, the procedure is completed.
...................................................................................................................................................................................................

2 At the Node B, increase the timer setting.

...................................................................................................................................................................................................................................
16-416 Alcatel-Lucent - Proprietary 401-382-290R04.03
See notice on first page Issue 1, August 2007
Corrective maintenance - RNC alarm clearance LCell_setupTimeout
procedures

...................................................................................................................................................................................................

3 If the problem persists, contact Alcatel-Lucent customer support.


END OF STEPS
...................................................................................................................................................................................................

...............................................................................