ULTRASONIC EXAMINATION REPORT

Work Order No. CMSS/18/516


Report no: CMSS/18/UT/026
Date of Test 18/04/2018
Client: Project name | Project No/PUMP No ----
Supplier --
Test reference Standard/ Procedure ASME SEC V, ARTICLE 4
Acceptance Criteria & Quality level ASME SEC V, ARTICLE 4
Scan Plan/Technique sheet Reference No. -----
Job Details
Job Identification Number Item Description AS PER ANNEXURE-I
Material Thickness Range
Material Grade EN19
(Min/Max.)
Drg Number
Stage of test After Rolling
Extent of Examination
As Rolled 100% Of the feasible area
Surface Condition
Equipment Details
Equipment Make and model
EECI ADVANSCAN AS-414 Equipment SL.NO. AS 4090 KP
number
Calibration done and due date 30/3/2018 TO 29/03/2019 Type of Couplant SAE 30 Motor Oil

Technical Details
Techniques Used Pulse Echo/ Contact method V2 –BLOCK
Calibration Block details
Method of sensitivity Calibration Used
Test Parameter details
Cable Length
Probe Sl NO

Reference
Gain (dB)
Search Unit
Transducer

Test Range
Frequency

Dia of the

Sound path Size of reference


Type of

Velocity
Sl .NO.

(m/sec)

(MHZ)
Waves

calibration details reflector


Model

probe

1mm V-Notch
V-2 Block
AM60-4L

066CAI

34.5+6db
2 Meter
Shear

4 MHz

0-100
3230

8X9

Test observations
Method of evaluation With DAC 1mm V-Notch Block
Total Number Non-Acceptable Total Number
Total Number of indications found Nil indications Nil Recordable/Acceptable Nil
indications
Indication location Map reference Results: No defect indications are found hence tested Weld joints are
-----
No. acceptable as per applicable standard.
Tested By Witnessed By: XYLEM Witnessed By: MEIL Witnessed By:
Customer
Name :B.SANDEEP Name :M.THIRUMALAI KUMAR Name :SHIVA DURGA RAO
Level Of qualification :ASNT Level- II Signature : Signature :
Signature :

Page 1 of 2 Format No: CMSS/FM/48B (UT)


Rev. No: 01; DT: 07/02/2017
ANNEXURE-1

REPORT NO. CMSS/17/UT/058 , Date: 06-12--2017

SI.NO COMPONENT DWG.NO JOINT No QTY Test Result


FORMED SUCTION INTAKE FJ1(ASSY Acceptable
1 08-5016-001-003 1
[pump no : 05] 1To2)
FORMED SUCTION FJ2(ASSY Acceptable
2 08-5016-001-003 1
INTAKE[pump no : 05] 2To3)

Tested By : Witnessed By: XYLEM Witnessed By: MEIL Witnessed By:


Customer

Name :B.SANDEEP Name :M.THIRUMALAI Name :SHIVA DURGA


Level Of qualification :ASNT KUMAR RAO
Level- II Signature : Signature :
Signature :

Page 2 of 2