Sie sind auf Seite 1von 17

Gorhar-Khairatunda

Subject: Estimation of VUP At Km 1+330

DATA
No of spans 2 skew angle
Span 12.00 m carriageway
Clear height 6m overall width
Depth of foundation 1.25 m no. of carriageways
Carriage way width 27.00 m span
Overall width 29.8 m median gap
Top slab thickness 0.8 m d
Outer wall thickness 0.8 m f
Innerwall thickness 0.75 m g
Raft thickness 0.9 m e
Raft projection 0m
Total length of top slab 26.35 m
Total length of raft 26.35 m
Height of wall 6m

Quadrants
numbers 0 x dir y dir
Radius 11.9 m 13.6 10.2
Depth 7.9333 m
v1 294.12 m
v2 268.9 m
v3 256.8 m
v1-v2 25.211 m
v2-v3 12.058 m

Curtain walls
Length 45.15 m
Width-U/S D/S 1.3 m 1.65 m
Depth on U/s 2m Retaining wall dimensions details
Depth on D/s 2.5 m
Retaining wall(Part 2) S.No Ht above G
No 0 h
Length 9.4975 m 1 2.000
Ht above gl 7.9333 m 8.00 2 2.500
Depth of foundation 2.000 m 3 3.000
Height of wall 8.433 m 4 3.500
Topwidth 0.300 m 5 4.000
below Wall 1.000 m 6 4.500
heel 3.600 m 7 5.000
Toe 2.600 m 8 5.500
Total width 7.200 m 9 6.000
Uniform Thickness 0.300 m 10 6.500
Variation Thickness 1.200 m 11 7.000
12 8.000
Retaining wall(Part 1) 13 9.000
No 0
Length 0m
width 0m
Depth 6.8 m
RE wall
No 0.00
Maximum height 7.80 m
Min height 0.50 m
Length of RE wall 0

Item Description Unit No L B D Quantity


No.
6.01 Earthwork in excavation of foundation for
structures complete as per drawing and
Technical Specification Clause 304 including all
Leads and Lifts

a)Ordinary and soft Soils


RC Box Cum
Retaining wall Cum
Median wall Cum

b) In soft rock Cum


b)Hard rock Cum
6.02 Providing Back filling for quadrants, with
selected imported granular material of approved
quality including all leads and lifts complete as
per Technical Specification Clause 305.

Cum
Cum

6.03 Filter media behind abutments,wing walls and


return walls complete with all leads and lifts as
per drawing and Technical Specification Clause
2200

Behind Side walls Cum


Behind Retaining walls Cum
Behind median walls Cum

6.04 Providing Plain Cement concrete for levelling


course etc., under foundations including
centering complete as per drawing and Technical
Specification clauses 1500,1700,& 2100.

PCC M15 grade for box Cum


PCC M15 grade for Retaining walls Cum
PCC M15 grade for median walls Cum
PCC M15 grade for curtain walls Cum

6.05 Providing and laying Reinforced cement concrete


for foundations complete as per drawing and
Technical Specifications Section 1500,1700, 2100
& 2200

PCC M15 Curtain wall Cum


RCCM35 for box raft Cum
RCCM35 for retaining walls (uniform thk) Cum
RCCM35 for retaining walls (Varying thk) Cum
RCCM35 for retaining walls (uniform thk) Cum
RCCM35 for retaining walls (Varying thk) Cum

HYSD bar reinforcement (Fe 415 gr)complete as


per drawing and Technical Specification clause
no 1600.
Mt
6.06 Structural Cement concrete for Reinforced
cement concrete for Sub structure including
centering complete as per drawing Technical
specification clauses 1500,1700,2200

PCC M30 Cum


RCC M35 for outersidewalls Cum
RCC M35 for innersidewalls Cum
Haunches Cum
Bracket Cum
Retaining wall Part 2 Cum
Retaining wall Part 1 Cum
Median wall Cum

HYSD bar reinforcement (Fe515 gr)complete as


per drawing and Technical Specification clause
no 1600.
Mt
6.07 Structural Cement concrete for Reinforced
cement concrete/PSC Super structure including
centering complete as per drawing Technical
specification clauses 809,1500,1700

RCC M35 for top slab Cum


PSC M50 Cum
HYSD bar reinforcement (Fe415 gr)complete as
per drawing and Technical Specification clause
no 1600.
Mt
6.08 HT Steel for PSC concrete complete as per
drawing and Technical Specification 1800,1009
Mt
6.09 Providing, cutting, bending and fixing in position
of TMT bar reinforcement(Fe 415 gr) in
reinforced concrete structure complete as per
drawing and Technical Specification Section 1600

Mt
6.10 Providing bored cast-in-situ M35 grade RCC piles
excluding reinforcement complete as per
drawings and technical specifications and
removal of excavated earth with all lifts and lead
up to 1000 m(pile dia 1200mm)

RCC M35 1.2m dia piles Rm


6.11 Bituminous Concrete Wearing Course of total 65
mm thick comprising two layers of 25 mm thick
Bituminous Concrete laid over a coat of 15 mm
thick Mastic Asphalt as per Technical
Specification Sections 509, 515, 521, & 2700.

Sqm
6.12 Providing and fixing drainage spouts complete as
per drawing, Technical Specification clause 2705.
Nos
6.13 Providing and fixing bearings complete as per
drawing and Technical Specification 2000,2200
and 2300.
a) Elastomeric bearings CC
b) Pot bearings nos
c) Kraft Paper / Tar Paper bearings sqm
6.14 Providing and fixing expansion joints complete
as per drawing and Technical Specification No.
2600 and confirming to MoRT&H modified
interim specifications

a) Filler joint / mastic Pad rm


b) Strip seal type of expansion joint complete as
per drawing and Technical specification for+/-20
mm
rm
c) Strip seal type of expansion joint complete as
per drawing and Technical specification for+/-50
mm
rm
6.15 Providing PCC M15 grade concrete for levelling
course under Approach Slabs Cum
6.16 Providing Reinforced Cement Concrete M 30
grade in approach slabs including reinforcement
complete as per drawings and Technical
Specifications 1500,1600 and 1700 & 2704

RCC M30 Cum


6.17 Filter media (150 mm thick) underneath pitching
in slopes and flat surfaces complete as per
drawing & Technical Specification Clause 2504
Cum
6.18 Stone pitching on sloped sufaces (300 mm thick)
for earth protection complete (for Quadrants) as
per drawings and Technical Specification 2504
Cum
6.19 Providing weep holes in abutments, wing walls
and return walls complete as per drawing and
Technical Specification 2706.
Nos
6.20 Providing and constructing RCC crash barrier M
40 grade including cost of centering as per
approved Drawings and Technical Specifications
Clause 809 and as per IRC-6

Rm
6.21 Painting of CD No. and Span arrangement as per
Technical specifications Nos 2 2
6.22 Providing and laying Dry Boulder apron complete
as per Drawings and Technical Specifications
Clause 2503
Cum 1 45.15 9 1.00 406
6.23 Providing and laying PCC filling for bed
protection as per Drawings and Technical
Specifications
PCC M15 grade Cum 2 391.6 area 0.15 117
PCC M15 grade Cum Total = 352
6.22 Confirmatory bores Nos 1 1
6.22 RCC M30 Hand rail Rm 2 33.35 67
6.22 Tubular railing Rm 4 33.35 133
median Ex width
13.4 3 13.4 = 29.8

0.00
13.50
14.90
2.00
12.00
0.00

ing wall dimensions details

Total Ht. Df Below GLTotal width Top width Bott width Heal Toe End thk Taper thk SBC
H df A a b c d t1 t2 t/sqm
3.500 1.500 2.900 0.300 0.400 2.000 0.500 0.300 0.700 13.000
4.000 1.500 3.400 0.300 0.400 2.400 0.600 0.300 0.800 13.000
4.500 1.500 3.800 0.300 0.500 2.600 0.700 0.300 0.900 13.000
5.500 2.000 4.400 0.300 0.500 2.600 1.300 0.300 0.900 15.000
6.000 2.000 4.600 0.300 0.600 2.600 1.400 0.300 0.900 15.000
6.500 2.000 5.000 0.300 0.700 2.800 1.500 0.300 1.000 15.000
7.000 2.000 5.400 0.300 0.800 2.900 1.700 0.300 1.000 15.000
7.500 2.000 5.700 0.300 0.800 3.000 1.900 0.300 1.000 15.000
8.000 2.000 6.100 0.300 0.900 3.000 2.200 0.300 1.000 15.000
8.500 2.000 6.500 0.300 0.900 3.200 2.400 0.300 1.100 15.000
9.000 2.000 6.900 0.300 0.900 3.400 2.600 0.300 1.100 15.000
10.000 2.000 7.200 0.300 1.000 3.600 2.600 0.300 1.200 15.000
11.000 2.000 8.000 0.300 1.000 4.000 3.000 0.300 1.400 15.000
considered in road bills
shear key 2 26.4 0.135 7.1145
1
1.1
1.2
1.2
1.2
1.3
1.3
1.3
1.3
1.4
1.4
1.5
1.7
Gorhar-Khairatunda
VEHICULAR UNDERPASSES VUP
Item No Description Unit 1+330

Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting out, construction of shoring and
6.01 bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom and backfilling with approved material etc. and as per
relevant clauses of section 300 & 2100 in

a) In all types of soil including ordinary rock by mechanical means


cu.m 0

b) In Hard rock not requiring blasting cu.m


c) In Hard rock with controlled blasting where blasting is prohibited
cu.m

Providing Back filling behind abutment, wing wall and return wall with
6.02 Granular Material complete as per drawing and Technical specification Cum 0
and as per relevant clauses 305 of specifications

Providing and constructing filter media behind abutments, wing


6.03 walls, retaining walls and return walls complete as per Drawings and Cum 0
Technical Specifications Clause 305 and 2504.

Provdiing and laying Plain cement concrete in open foundation including


form work shuttering etc. complete as per drawing and technical
6.04 Cum 0
specifications and as per relevant clauses of sections 1500, 1700 & 2100
with P.C.C. M-15 grade in leveling course

Providing and laying Plain cement concrete in Foundation of complete


section as per drawing and technical specifications and as per relevant Cum
clauses of sections 1500, 1700 & 2200 in PCC M - 25 grade Concrete

Providing and laying Reinforced cement concrete in Foundation of


complete section as per drawing and technical specifications and as per
6.05 Cum 0
relevant clauses of sections 1500, 1700 & 2200 in RCC M - 30 grade
Concrete

Providing and laying Plain cement concrete in Sub-Structure of complete


section as per drawing and technical specifications and as per relevant Cum
clauses of sections 1500, 1700 & 2200 in PCC M - 25 grade Concrete

Providing and laying Reinforced cement concrete in sub-structure of


6.06 complete section as per drawing and technical specifications and as per Cum 0
relevant clauses of sections 1500, 1700 & 2200 in M - 30 grade Concrete

Supplying, fitting and placing un-coated HYSD bar reinforcement in


6.07 foundation complete as per drawing and technical specifications and as MT 0
per relevant clauses of sections 1600.

Supplying, fitting and placing HYSD bar reinforcement in sub-structure


6.08 complete as per drawing and technical specifications and as per relevant MT 0
clauses of sections 1600.
Providing and Fixing Tar Paper Bearing complete as per drawing and
6.09 Sqm 0
Technical Specifications Section
Supplying, fitting and fixing in position true to line and level elastomeric
6.09 bearings confirming to IRC:83:(Pt.II) section IX complete including all Cu.Cm
accessories as per drawing and specifications as per section 2000.

6.09 Pot/PTFE Bearings Nr.


Providing and laying Reinforced cement concrete in super-structure as
6.10 per drawing and Technical Specification and as per relevant clauses of
sections 1500, 1700 and 2300 in
RCC M 30 Grade Concrete (Deck slab) Cum
RCC M 35 Grade Concrete (Deck slab) Cum 0
RCC M 40 Grade Concrete (Deck slab) Cum
PSC M 45 Grade Concrete (Girder) Cum
RCC M 45 Grade Concrete (Deck Slab) Cum

Providing and laying Prestressed cement concrete in super-structure as


6.11 per drawing and Technical Specification and as per relevant clauses of Cum
sections 1500, 1700 and 2300 in RCC M 45 Grade Concrete - I Girder

Providing and laying Prestressed cement concrete in super-structure as


per drawing and Technical Specification and as per relevant clauses of Cum
sections 1500, 1700 and 2300 in RCC M 45 Grade Concrete - Box Girder

Providing and laying Plain cement concrete in Approach Slab as per


6.12 drawing and Technical Specification and as per relevant clauses of Cum 0
sections 1500, 1700 and 2300 in M- 15 Grade

Providing and laying Reinforced cement concrete in Approach Slab as per


6.13 drawing and Technical Specification and as per relevant clauses of Cum 0
sections 1500, 1700 and 2300 in M- 30 Grade

Supplying, fitting and placing HYSD bar reinforcement in super-structure


6.14 complete as per drawing and technical specifications as per relevant MT 0
clauses of section 1600 of specifications.
Providing Drainage Spouts complete as per drawing and Technical
6.15 Nr. 0
specification and as per clause 2705 of specifications.
Reinforced cement concrete Crash Barrier (M-40 Grade) complete as per
6.16 drawing and Technical Specification Sections 1500, 1600, 1700, 2700 and RMT 0
809 and Clause 2703
6.16 Providing M 30 Grade Concrete Railing RMT

Providing and laying of a strip seal expansion joint catering to maximum


horizontal movement upto 70 mm, complete as per approved drawings
and standard specifications to be installed by the manufacturer/ supplier
6.17 RMT
or their authorised representative ensuring compliance to the
manufacturer's instructions for installation and as per relevant clauses of
section 2600.

Providing and laying 65 mm thick Wearing Course consisting of 40mm


6.18 thick bituminous concrete over 25mm thick bitumen mastic layer Sqm 0
complete as per drawing and Technical Specifications Clause 2702.
Providing High tensile steel wires/strands including all accessories for
6.19 stressing, stressing operations and grouting complete as per drawing MT
and Technical Specifications and as per relevant clauses of section 1800.

6.20 Providing Weep Holes Nr. 0


6.21 Retaining wall
Excavation Cum
M 15 Grade Concerte Levelling Course Cum
M 30 Grade Concrete Cum
HYSD MT
Concrete Crash Rmt

Providing bored cast-in-situ M-35 grade R.C.C. pile excluding


reinforcement complete as per drawing and technical specifications and
6.24 RMT
removal of excavated earth with all lifts and lead upto 1000 m. (Pile
diameter-1200 mm) and as per specifications 1100, 1600 and 1700.

Providing bored cast-in-situ M-40 grade R.C.C. pile excluding


6.24 reinforcement complete as per drawing and technical specifications and RMT
removal of excavated earth with all lifts and lead upto 1000 m. (Pile
diameter-1200 mm) and as per specifications 1100, 1600 and 1700.

Providing and laying Cement concrete for reinforced concrete in pile cap
6.25 complete as per drawing and Technical Specification and as per relevant Cum
clauses of sections 1100, 1500 & 1700 with M 35 Grade Concrete

Providing and laying Cement concrete for reinforced concrete in pile cap
6.25 complete as per drawing and Technical Specification and as per relevant Cum
clauses of sections 1100, 1500 & 1700 with M 40 Grade Concrete

Providing and laying flexible apron in the upstream and downstream of


structure for protection against scour with stone boulders weighing not
less than 40 kg each including all labour , materials, machinery, all leads
6.26 Cum
and lifts, compacting to the satisfaction of the Engineer etc. complete as
per drawing, Technical Specification Section 2500 and as directed by the
Engineer .
Providing Rigid Apron ambeded in 300mm thick stone with M 15 Grade
6.27 Cum
Concrete

Providing and laying plain cement concrete for curtain wall including
6.28 shuttering all complete as per drawing and Technical Specification Clause Cum 0
1500, 1700, 2100, 2200 & 2300 with M15 Concrete.

Providing and laying stone pitching in slopes complete as per


6.29 Cum 0
drawing and Technical
Providing and laying filter material underneath stone pitching in slopes
6.30 Cum 0
complete as per drawing and Technical Specification Section 2500.
Providing and laying Layer of Sand and Boulder for leveling course
6.31 Cum
below PCC layer of M15
addl Filler joint / mastic Pad Sqm 0
Painting of CD No. and Span arrangement as per Technical
addl Nr. 2
specifications
addl Confirmatory bore holes for soil investigation reprot Nr. 1
Total Amount of Bill No. 6
Quantity

0
0

0
0
0
0
0

0
0

0
0
0
0
0
0
0

0
0

Das könnte Ihnen auch gefallen