Avery Weigh-Tronix Technical Specification E1205

E1205
advanced multi-function indicator
Description
General
This specification describes the
E1205 advanced multi-function
weight indicator, capable of
stand-alone operation, or of
integration into a larger system via
serial, FieldBus and Ethernet
interfaces.

It is a microprocessor-based
industrial weighing system with up
to 100,000 displayed increments for
analysing, displaying, storing and
transmitting gross and net weight
information.

Up to 12 analogue load cells to be


connected with the indicator
(16 with second scale).
Alternatively, up to eight Avery
Weigh-Tronix digital load cells may
be used.

This indicator can display weight


data from two scales
simultaneously. Both scales are
active and are independently
weighing at all times.
zz Sensitivity to weight signal zz Ten points for linearity
The E1205 can be matched to correction to ensure maximum
almost any load cell system to zz Scale capacity
accuracy
achieve optimum accuracy, stability zz Number of divisions and
and repeatability. zz Tare availability and manner of
increment size
operation
The indicator can control its zz Weighing Unit
zz Time and date (two or four
surrounding process using fully zz Zero/back balance digit year, battery backed)
configurable I/O.
Alternatively, control can be zz Decimal marker type - point or zz User-definable serial output
executed from a central system comma strings
using an extensive range of zz Position of decimal marker zz Subtotal and grand total
available interfaces. information
zz Calibration site gravity factor
Configurable Features zz Scale ID number
zz Customer site gravity factor
The E1205 features a dual purpose zz Alarm index operation
alpha-numeric keyboard which zz Filtering using FIR or
allows any of the following Harmonizer™ filtering systems zz Recipe/filling I/O
functions to be configured during configuration
commissioning:
E1205 Avery Weigh-Tronix Technical Specification

All these characteristics are stored Database supports:


in non-volatile memory so that once zz Vehicles Specification
the ideal parameters for any given zz Hauliers
weighing system are established zz Suppliers / Customers Electrical
they can be retained with certainty zz Browsing
for the future. zz Outstanding vehicle report
Display
Once the scale is set up as required, Three Level Pack Run Monitoring
Type
a calibration report can be printed Set all parameters to monitor and
Blue back-lit LED.
showing weighing details (useful manage the packing of components
Graphics 64 x 240 pixels.
for the installation engineer). This into boxes, and overpacking into
Displays up to eight digits.
allows the state of the system to be cartons and onto pallets. Produce
monitored. all labels as required for tracking.
Decimal Points
Configurable to any of seven
Up to 300 product look ups (PLUs) Conversion Factor
positions
are available for instant recall of Enter the factor required to convert

previously programmed to custom unit
Units Displayed
product information.
g, kg, lb(dec), tons, tonnes, custom.
Recipe/Filling
Control of complete process using
Applications fully configurable trips.
Annunciators
Balance (Gross Zero)
In-flight compensation and dosing
Parts Counting Motion
variables may be set to optimise the
Sampling modes supported: fast; Pre-set Tare
process. Batching mode allows
dribble; bulk Semi-Automatic Tare
repetition of the process for a
Net
defined quantity.
Static Weighing lb or kg
Set limits, either absolute or relative Print
Totalising Against Dedicated
to target. Set check-weigh bar step Three-off Trip Indicators
Product Look Ups (PLUs)
size. Minus (below net zero)
Link weighings to PLUs for complete
Scale 1
stock control.
In-Motion Weighing Scale 2
The indicator can be used to control
Product List Description and
the in-motion process as required. Keypad
Totalising
Create customised print-outs
Peak Hold 28 keys, addressing:
itemising customer transactions,
Records maximum weight Alpha entry
with grand totals.
measured. Clear button resets Numeric entry
memory Five soft Function keys
Type Through Mode
Allowing any text to be input on the Dedicated Function Keys
Weighbridge Zero, Tare, Select, Print, Units, Totals,
E1205 and printed out in full on an
A broad application, offering the Scale, PLU, Standby, Escape, Enter,
attached printer or suitable
following functions. Clear, Text
computer system.
Three core operating modes - Remote IBM PS/2 keyboard input
Terminal Mode
zz Re-entered first weight included (requires interface cable)
Giving enhanced PC control and
zz Stored and printed
power.
zz Stored first weight
Remote Display Mode
Additional modes:
zz Public weighing
Connect to, or use as a remote Load Cell Input
display.
zz Axle weighing (up to 10 axles)
zz Part loads Analogue Input
zz Two platform in/out operation Combined minimum load cell
zz Simple stock control impedance must be greater than
zz Net weight adjustment (dirt 22Ω.
allowance)
Maximum Load Cells if 350Ω (One
Scale)
12.

Total 350Ω Load Cells if 2nd


Analogue Input Fitted
16.

2
Avery Weigh-Tronix Technical Specification E1205

Connection of Input
Direct wired (Buccaneer if supplied Analogue to Digital
with scale). Convertor
Excitation Display Update Rate
Direct current. 1, 2, 5, 10 per second.

Voltage A to D Rate
10 V dc. 120 per second.

Current A to D Type
Up to 460 mA Delta Sigma.

Remote Sense
Obtained from excitation, or Filter
Linked directly to reference input
connectors at the indicator. FIR & Dynamic Filtering
Seven programmable Options
Input Impedance
1MΩ paralleled with 2.2nF. Associated Filter Attributes
Filter Level Display Weight Noise Noise
Signal Response Time Sample Rate Amplitude Frequency
6-20 mV maximum. (seconds) (Hz)

uV/ per Division 0 0.20 8.13 Lowest Highest
0.6
1 0.35 8.13
Resolution 2 0.53 8.13
Approved 10,000 3 0.96 8.13
Non- Approved 100,000 4 1.45 8.13
Digital Input 5 2.09 8.13
Connects to T301 digital load cells 6 2.85 8.13 Highest Lowest
via T301 junction box.
Requires Digital Option Card.
Dynamic Filter
Applied after the FIR filter. Balance/Zero
Calibration Set the filter window size in
divisions (0 - 99). A high value will Setting
Full digital multi-point (ten point) have a large damping effect on the Keyboard push button.
calibration. weight display.
This significantly slows the scale Operation
Theoretical calibration possible if response to a legitimate change in Ignore or recall limit exceeded.
parameters known. weight.
Size of Balance Range
Provides over load report. Harmonizer™ Digital Filter Normally 2%, up to 100%.
Three programmable parameters:
Increment Multiplier Zero Indication
1, 2, 5,10, 20, 50, 100, 200, 500. Samples to Average - sets number Within 2% of maximum capacity.
of A-D conversions which will be
AVR averaged to give a weight reading. Under Range Indication
Three stage. Displays ‘Under Range’.
IIR Filter - sets how much
Gravity Compensation damping the Harmonizer™ applies Zero Tracking
Set gravity for calibration and to the weight reading. Typically Configurable
installation site. between 1 (low) - 8 (higher).
Motion Detection
Threshold Level - sets the Configurable.
minimum weight change (in
calibration units) which the
Harmonizer™ will not attempt to
filter out as noise.

3
E1205 Avery Weigh-Tronix Technical Specification

Other variables that can be config-


Range/Span Trips ured in Recipe / Filling mode are:
Range of Adjustment The indicator has three internal trips zz Outputs at start of step
0 - 100,000 divisions. as standard, and can support up to zz Outputs at end of step
16 external trips via external Trips zz Target action (e.g. print)
Over Range Indication Interface Units zz PLU to accumulate totals data
Displays ‘Over Range’. (see accessories).
All trips (both internal and All configuration information is
Tares external) are rated at 240 V 2 A. retained when power is off.
Internal inputs are rated at TTL
Three types of tares are available. levels.
Each is 100% subtractive. TIU8 inputs rated 10 - 30 V DC.
Product Look Ups
Note: Interlocks between the tare Two modes have independent (PLUs) & Totals
types are configurable at time of control of the trip outputs, Alarm
commissioning. and Recipe. Alarm mode operates Information Stored per PLU
continuously. Sub-totals and grand totals.
Type A - Push-Button (Semi Auto) Recipe mode is dependant on the Application specific info stored per
Tare Recipe / Filling application being PLU.
Push-button operated, semi- configured and in operation. Memory protection of PLUs.
automatic, with selectable negative
weight display. Cumulative taring is Alarm Mode Maximum capacity of each PLU
possible. Alarm mode has 10 independent 999,999,999.
configurable indexes, and cannot
Initialisation and Operation be turned off. Each index can be
When the item to tare on is applied, User Definable Text Fields per PLU
programmed to operate any or all 3, each 21 characters.
press the ‘Tare’ push-button. outputs based on a given target:
Indication When a PLU is recalled, the indicator
zz None - index inactive is automatically configured into the
‘Net’ annunciator is illuminated.
zz Target Weight application programme of the PLU.
Type B – Keyboard (Pre-set) Tare zz Status of indicator, e.g. weight All information on the PLU can be
Keyboard-entered tare operated steady, checkweigh accept displayed as well as printed.
with negative weight display. zz Input (single or specific
pattern)
Initialisation & Operation zz Output (single or specific
Enter pre-set tare value using the pattern)
0-9 keypad and press ‘Tare’ push zz Time Real Time Clock
button. Multiple pre-set tares are The E1205 is fitted with a real time
possible. Recipe /Filling Mode clock which allows the user to
Recipe/Filling mode has 50 display and print the time and date.
Indication configurable sequential steps, This clock is battery-backed and will
‘Net’ annunciator is illuminated and is active only in Recipe/ Filling remain functional in the absence of
together with pre-set tare mode. Each recipe (maximum 100) mains power.
annunciator (PT). can be configured independently
to the others. Each index can be
Type C - Stored Tare programmed to operate any or all Communications
Stored tare operated with negative outputs based on a given target:
weight display allowing 40 separate Serial Interface
stored tares. Will be retained when zz None – index inactive Two bi-directional asynchronous
power is off. Linked to any PLU. zz Target Weight (includes serial interfaces (RS232/485/422 and
tolerance, compensation and RS232/20mA current loop) as
Initialisation & Operation standard. Two additional via
dosing parameters)
Automatically activated when PLU optional digital interface card.
activated. zz Status of indicator, e.g. weight
steady, checkweigh accept
zz Input (single or specific Networking
Indication Ethernet 10/100 TCP/IP interface as
‘Net’ icon is illuminated together pattern)
zz Output (single or specific standard.
with preset tare icon (PT).
pattern)
zz Time Fieldbus interfaces – optional – see
Kits.

4
Avery Weigh-Tronix Technical Specification E1205

Electrical Power Input Mounting Options Approvals



Voltage The indicator will desk, wall or pole All data relating to the performance
110 VAC - 230 VAC nominal, mount. of the instrument meets or exceeds
50/60 Hz. the requirements of EN45501:1994
Pole mounting requires optional and OIML R76-1:2006, accuracy
Tolerance adapter. Class III for Non-Automatic
Voltage -15 to +10%. Weighing Instruments and OIML
R61-1:2004, Reference accuracy
Frequency ±10%. Performance class ≥ 0.1 for Automatic

Power Consumption Gravimetric Filling instruments
Internal Resolution
30 VA maximum when used with under the European Measuring
16,777,216.
full configuration of load cells. Instruments Directive. The
associated certificate numbers are:-
Repeatability
Cable Length ± 0.01% of full scale.
2 m. EC Type Approval Certificate
UK2694
Span Drift Time
Power Supply ± 50 ppm/year max.
Internally fitted, switched mode. OIML Certificate of Conformity
R76/2006-GB1.10.01
Span Drift Temperature
Isolation Protection ± 4 ppm/° C typical.
None. Mains earth lead must be EC Type Examination Certificate
connected to safety earth. UK/0126/0080
Zero Drift Time
± 10 ppm ±0.1% DL/year maximum.
Evaluation Certificate
Environment GB-1369
Zero Drift Temperature
Resistance to Dirt and Moisture ± 2 ppm ± 40 ppm DL/ °C

Protected to IP54, in moulded plas- maximum.
tic enclosure.
Factory Options
Warm Up Time
Electrical Disturbance Immediate self test complete. Choice of mains power connector:
Immune to electrical disturbance, UK, Euro, Australian, South African,
including RFI as detailed in Self Diagnostics American.
EN 45501:2004 Graphics Display
Keys
Operating Temperature
-10° C to + 40° C. PS/2 Keyboard
A2D (x 2)
Service Temperature Serial Test (4)
-10° C to + 55° C.
Network interface
Storage Temperature Ethernet port
-40° C to +70° C. BCD Out
Analogue Out
Finish Pulse In
Enclosed in moulded ABS plastic Memory
case. Tally Roll
Internal I/O
External I/O

5
E1205 Avery Weigh-Tronix Technical Specification

7. Ethernet IP Interface Kit


Kits Enables interfacing to Ethernet Accessories
Industrial Protocol (IP) network.
The following kits are available to 1. Trips Interface Unit (TIU8)
Includes Electronic Tally Roll card as
enable local configuration when Provides eight external I/O in place
standard to provide interface.
required. of three internal I/O included as
standard.
8. ModBus TCP Interface Kit
1. Analogue Card Inputs rated at 10 - 30 V dc, outputs
Enables interfacing to ModBus TCP
Provides second analogue scale rated at 240 V 2 A.
or Ethernet (over Modbus TCP)
input and two analogue outputs
network.
4-20 mA (resolution 1:5000). Two TIU8s may be connected to the
Includes Electronic Tally Roll card as
E1210 to provide a total of
standard to provide interface.
2. Digital Card 16 I/O.
Provides two additional bi- E11100E00000000
9. Platform Connection Loom Kit
directional asynchronous serial When ordering E1205 to be con-
interfaces (RS232/485/422 and nected and shipped with a platform, 2. 300 mm Pole
RS232). Also includes BCD output other than H205, H503 or H303, a Stainless steel mounting pole with
(range 1 - 100,000) and pulse input. platform connection loom kit must top mounting plate for indicator.
Required for operation with T301 be ordered: E11100U00000000
load cells. 5 m: 70735-248
10 m: 70735-287 3. 1000 mm Pole
3. Electronic Tally Roll Card Stainless steel mounting pole with
Securely stores and prints up to top mounting plate for indicator
72,000 transactions, with details E11100V00000000
of scale ID, gross/tare/net weights,
time, date and consecutive number. 4. Interface Leads for Platform to
Also acts as carrier for FieldBus card. Indicator
See price list.
4. ProfiBus DP Interface Kit
Enables interfacing to ProfiBus 5. Interface Leads for Indicator to
network. Includes Electronic Tally Printer
Roll card as standard to provide See price list.
interface.
6. Y808
5. ControlNet Interface Kit Large push button unit (up to four
Enables interfacing to ControlNet buttons).
network. Includes Electronic Tally
Roll card as standard to provide
interface.

6. DeviceNet Interface Kit


Enables interfacing to DeviceNet
network. Includes Electronic Tally
Roll card as standard to provide
interface.

6
Avery Weigh-Tronix Technical Specification E1205

Weight Dimensions
3.5 kg
292 188
Shipping Specification

Net
3.5 kg

Gross
4.8 kg
292
330
Measurement
345 mm x 270 mm x 335 mm

Harmonised Commodity Code


842390 00 0.

All dimensions in millimetres

7
E1205 Avery Weigh-Tronix Technical Specification

© Avery Weigh-Tronix group of companies 2009. All rights reserved. Avery Weigh-Tronix is a registered trade mark of the Avery Weigh-Tronix group of companies. This publication is issued to provide outline information only which,
unless agreed by an Avery Weigh-Tronix group company in writing, may not be regarded as a representation relating to the products or services concerned. This publication was correct at the time of going to print however,
Avery Weigh-Tronix reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time.

Your local distributor:

Foundry Lane, Smethwick,


E mail: info@awtxglobal.com West Midlands, England B66 2LP.
Internet: http://www.averyweigh-tronix.com Tel: +44 (0)845 3 66 77 88 Fax: +44 (0)121-224 8183

Produced by Avery Weigh-Tronix Publicity Department E1205/08.10/Issue 7