5000mm wide and 14000mm long. Flank walls and toe 400mm thick reinforced with A393 mesh on centre line with T10 "L" bars @ 200mm cs to upper surface. Allow for haunching at junction with upper face. Ensure full compaction of concrete.
E3 Allow for timber formwork as necessary
and strike oil as necessary.
E4 Allow to backfill with rubble and
thoroughly compacted fill to form base to upper face of slipway E5 Upper face of slipway nom 250mm thick with A393 mesh top and bottom having 75mm cover and tied to "L" bars in toe and flank walls. Ensure full compaction of concrete.
Upper surface to receive tamped finish.
Flank walls to have as struck finish
Supply and fix galvanised steel fence
embeded on both sides of retaining wall1.8m high.
Supply and install paving stones on area
adjacent to slipway UNIT RATE AMOUNT SCHEDULE SUMMARY
Section C – Demolitions and Alterations
Section D - Excavations Section E – Concrete Work Section F - Masonry Section G – Structural Metal/Carpentry Section P - Building Fabric Sundries