Sie sind auf Seite 1von 12

Indoor Unit Lineup

Daikin offers a wide range of indoor units includes both VRV and residential Ceiling Suspended Type Wall Mounted Type
models responding to variety of needs of our customers that require FXHQ-MAVE FXAQ-PVE
air-conditioning solutions.

VRV Indoor Unit


Stylish flat panel design
Slim body with quiet and wide harmonised with your interior
Ceiling Mounted Cassette Ceiling Mounted Cassette airflow décor
(Round Flow with Sensing) (Round Flow) Type
Type FXFQ-LUV1 Floor Standing Type Floor Standing Duct Type
FXFQ-SVM FXLQ-MAVE FXVQ-MY1
FXVQ-MY16
(high static pressure type)

Concealed Floor Standing


Presence of people and floor 360 airflow improves temperature Type
temperature can be detected to distribution and offers a comfortable
FXNQ-MAVE
provide comfort and energy savings living environment.
Large airfiow type for large spaces.

Indoor Unit Lineup


Suitable for perimeter zone air conditioning Flexible interior design for each tenant.
Ceiling Mounted Cassette 4-Way Flow Ceiling
(Compact Multi Flow) Type Suspended Type
FXUQ-AVEB
Residential Indoor Units with connection to BP unit.
FXZQ-MVE

Ceiling Mounted Cassette Ceiling Mounted Cassette


Type (Compact Multi Flow) Type
FCQ-BVE FFQ-BV1B
This slim and stylish indoor unit
achieves optimum air distribution,
Quiet, compact, and designed for and can be installed without the
user comfort need for ceiling cavity.
Specially designed for false ceilings
—for a smooth, modern interior Quiet, compact, and designed for user
finish comfort
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Double Flow) Type Corner Type
Ceiling Mounted Built-in Slim Ceiling Mounted Duct
FXCQ-MVE FXKQ-MAVE
Type Type
FBQ-BV1 FDKS-EAVMB

FDKS-C(A)VMB

Thin, lightweight, and easy to install Slim design for flexible Flexible air discharge unit to fit Slim and smooth design suits your
in narrow ceiling spaces installation various forms of space shallow ceiling

Slim Ceiling Mounted Duct Ceiling Mounted Duct Wall Mounted Type
Type Type FTKS-DVM

FXDQ-PBVE(T) FXMQ-PVE

FTKS-BVMA

FXDQ-NBVE(T) FXMQ-MAVE
FTKS-FVM

Slim design, quietness and High external static pressure Stylish flat panel harmonises with
static pressure switching allows flexible installations your interior décor

17 18
Indoor Unit Lineup

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type

Sensing function Airflow block function *3


FXFQ25S / FXFQ32S / FXFQ40S Auto airflow rate mode + Auto airflow direction mode Total comfort by individual airflow direction control
Floor temperature is detected and over cooling and newly-equipped “airflow block function”
FXFQ50S / FXFQ63S / FXFQ80S
prevented.
FXFQ100S / FXFQ125S
Without sensing function Airflow block
air velocity
approx. 0.3m/s*4
30°C near ceiling

Room Area around feet gets


temperature is too cold because air

Presence of people and floor temperature can be


detected as conditioner continues
30°C. until the temperature
near the ceiling reaches

detected to provide comfort and energy savings


20°C near floor the set temperature.
Airflow block function prevents uncomfortable
drafts by reducing air velocity to approx. 0.3m/s.*4
Dual sensors detect the presence of people and floor With sensing function
temperature to provide comfortable air-conditioning and Automatic

Indoor Unit Lineup


energy savings. 30°C near ceiling control using
the temperature
Infrared presence sensor Room temperature is
calculated as 27°C in the area which near the person
is in the vicinity of the person. as the room
The sensor detects human presence 24°C near floor
temperature.
and adjusts the airflow direction
Airflow block Also can support
automatically to prevent drafts. for cabinet side such this case
The floor temperature, which is lower
than near the ceiling, is detected.
New airflow block function prevents
Energy savings uncomfortable drafts by reducing air velocity.
The temperature near the person is automatically calculated It can be set using the BRC1E62 remote controller.
by detecting the temperature of the floor. Energy is saved, There is no need for sealing material of air discharge
Presence of
people in 4 because the area around the feet does not get too cold. outlet (option).
areas
This function only works when all-round flow
Indoor unit offers 360° airflow discharges air in all is used. It cannot be used when sealing material is
directions with more uniform temperature distribution. Sensing sensor mode used in the air discharge outlet (option).
Sensing sensor low mode *1. 2
When there are no people in a room, Easy setup with remote controller
Detecting the the set temperature is shifted automatically.
average
temperature of Example: • Cooling setpoint: 26°C • Shift time: 30 min.
indoor floor
Dead spot of airflow • Shift temperature: 1.0°C • Limit cooling temperature: 30°C

28 28℃
Energy efficiency has been improved thanks to the 27 27℃

adoption of a new heat exchanger with smaller tubes, 26 26℃ 26℃

Setpoint (℃)
Automatically
DC fan motor and DC drain pump motor. Occupied
Unoccupied
reverts when
people return. Horizontal flow Airflow block
Infrared floor sensor
The airflow block function is
The sensor detects the floor temperature and Low operation sound level Time
useful when rearranging the
After 30 min After another 30 min
automatically adjusts operation of the indoor unit to
reduce the temperature difference between the ceiling FXFQ-S 25/32 40 50 63 80 100 125
If people do not return, the air conditioner will raise the
room layout. Airflow
block 500 mm*5
and the floor. Sound temperature 1°C every 30 minutes and then operate at 30°C.
level 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35
(H/M/L) Wall
Individual airflow direction control Shift temperature and time can be selected from 0.5 to 4℃
in 0.5℃ increments and 15, 30, 45, 60, 90 or 120 minutes *3. Works in one direction only.

Thanks to the individual airflow direction control function, Control of airflow rate can be selected from 3-step respectively with remote controller. *4. In case of FXFQ63S type (Data is based on Daikin research.)
*5. A gap of 1500 mm is required if the air block function is not used.
airflow direction can be individually adjusted for each air control, which provides comfortable airflow. Auto airflow
discharge outlet to prevent uncomfortable drafts and to rate control can be selected with wired remote controller Sensing sensor stop mode *1. 2
deliver optimal air distribution. BRC1E62. When there are no people in a room, the system
stops automatically.
Drain pump is equipped as
Absent stop time can be selected from 1 to 24 hrs in 1 hr
standard accessory with 850 mm 850 mm increments with remote controller.
lift. *1. These functions are not available when using the group control system.
*2. User can set these functions with remote controller.

19 20
Indoor Unit Lineup

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type

Sensing function Airflow block function *3


FXFQ25S / FXFQ32S / FXFQ40S Auto airflow rate mode + Auto airflow direction mode Total comfort by individual airflow direction control
Floor temperature is detected and over cooling and newly-equipped “airflow block function”
FXFQ50S / FXFQ63S / FXFQ80S
prevented.
FXFQ100S / FXFQ125S
Without sensing function Airflow block
air velocity
approx. 0.3m/s*4
30°C near ceiling

Room Area around feet gets


temperature is too cold because air

Presence of people and floor temperature can be


detected as conditioner continues
30°C. until the temperature
near the ceiling reaches

detected to provide comfort and energy savings


20°C near floor the set temperature.
Airflow block function prevents uncomfortable
drafts by reducing air velocity to approx. 0.3m/s.*4
Dual sensors detect the presence of people and floor With sensing function
temperature to provide comfortable air-conditioning and Automatic

Indoor Unit Lineup


energy savings. 30°C near ceiling control using
the temperature
Infrared presence sensor Room temperature is
calculated as 27°C in the area which near the person
is in the vicinity of the person. as the room
The sensor detects human presence 24°C near floor
temperature.
and adjusts the airflow direction
Airflow block Also can support
automatically to prevent drafts. for cabinet side such this case
The floor temperature, which is lower
than near the ceiling, is detected.
New airflow block function prevents
Energy savings uncomfortable drafts by reducing air velocity.
The temperature near the person is automatically calculated It can be set using the BRC1E62 remote controller.
by detecting the temperature of the floor. Energy is saved, There is no need for sealing material of air discharge
Presence of
people in 4 because the area around the feet does not get too cold. outlet (option).
areas
This function only works when all-round flow
Indoor unit offers 360° airflow discharges air in all is used. It cannot be used when sealing material is
directions with more uniform temperature distribution. Sensing sensor mode used in the air discharge outlet (option).
Sensing sensor low mode *1. 2
When there are no people in a room, Easy setup with remote controller
Detecting the the set temperature is shifted automatically.
average
temperature of Example: • Cooling setpoint: 26°C • Shift time: 30 min.
indoor floor
Dead spot of airflow • Shift temperature: 1.0°C • Limit cooling temperature: 30°C

28 28℃
Energy efficiency has been improved thanks to the 27 27℃

adoption of a new heat exchanger with smaller tubes, 26 26℃ 26℃

Setpoint (℃)
Automatically
DC fan motor and DC drain pump motor. Occupied
Unoccupied
reverts when
people return. Horizontal flow Airflow block
Infrared floor sensor
The airflow block function is
The sensor detects the floor temperature and Low operation sound level Time
useful when rearranging the
After 30 min After another 30 min
automatically adjusts operation of the indoor unit to
reduce the temperature difference between the ceiling FXFQ-S 25/32 40 50 63 80 100 125
If people do not return, the air conditioner will raise the
room layout. Airflow
block 500 mm*5
and the floor. Sound temperature 1°C every 30 minutes and then operate at 30°C.
level 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35
(H/M/L) Wall
Individual airflow direction control Shift temperature and time can be selected from 0.5 to 4℃
in 0.5℃ increments and 15, 30, 45, 60, 90 or 120 minutes *3. Works in one direction only.

Thanks to the individual airflow direction control function, Control of airflow rate can be selected from 3-step respectively with remote controller. *4. In case of FXFQ63S type (Data is based on Daikin research.)
*5. A gap of 1500 mm is required if the air block function is not used.
airflow direction can be individually adjusted for each air control, which provides comfortable airflow. Auto airflow
discharge outlet to prevent uncomfortable drafts and to rate control can be selected with wired remote controller Sensing sensor stop mode *1. 2
deliver optimal air distribution. BRC1E62. When there are no people in a room, the system
stops automatically.
Drain pump is equipped as
Absent stop time can be selected from 1 to 24 hrs in 1 hr
standard accessory with 850 mm 850 mm increments with remote controller.
lift. *1. These functions are not available when using the group control system.
*2. User can set these functions with remote controller.

19 20
Indoor Unit Lineup

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Cassette (Compact Multi Flow) Type

FXFQ25LU / FXFQ32LU / FXFQ40LU FXZQ20M / FXZQ25M / FXZQ32M


FXFQ50LU / FXFQ63LU / FXFQ80LU FXZQ40M / FXZQ50M
FXFQ100LU / FXFQ125LU

360° airflow improves temperature distribution Quiet, compact, and designed for user comfort
and offers a comfortable living environment. Dimensions correspond with 600 mm x 600 mm
architectural module ceiling design specifications.
The industry’s first* Round Flow Ceiling Mounted
Cassette type offers 360° airflow with improved

Indoor Unit Lineup


Low operation sound level
temperature distribution. (dB(A))
4-way flow FXZQ-M 20/25 32 40 50
Round Flow
Sound level
(H/L) 32/29 33/29 36/30 41/34

Comfortable airflow

There are areas of There are much fewer


1 Wide discharge angle: 0° to 60°
uneven temperature. areas of uneven temperature. Auto swing
* As of April 2004, the release date for Japan.
The light weight unit at 19.5 kg for FXFQ25-50LU
models makes installation easy.
Drain pump is equipped as a 0° 0°
850 mm
standard accessory with a 850 mm
lift. 60°
60°
A modern sophisticated decoration panel has been
Fixed angles: 5 levels
applied, with a panel surface that has been treated with
a dirt-repellant coating. An antibacterial treatment that uses silver ions has
Treated surface Untreated surface been applied to the drain pan, preventing the growth
Dirt and
of slime, mould and bacteria that cause blockages 0° 0°
Resists grime • Condition after and odours. Drain pump is equipped as standard accessory with
soiling exposure to the
smoke of 600
750 mm lift.
cigarettes in 1 m
3
The horizontal louvres prevent dew condensation. 60° 60°
enclosed space.
Their non-flocking surfaces, which repel dirt, are *Angles can be also set on site to prevent drafts (0°-35°)
Control of the airflow rate can be selected from 3-step easy to clean. or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).
control. 750 mm
The air filter has an anti-mould and antibacterial 2 2-, 3-, and 4-way airflow patterns are available,
Low operation sound level (dB(A)) enabling installation in the corner of a room.
FXFQ-LU 25/32 40 50 63 80 100 125
treatment that prevents the growth of mould
Sound generated from dust or moisture that may adhere to
level
(HH/H/L)
30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 the filter.

Example of airflow patterns: All-round flow 4-way flow 3-way flow L-shaped 2-way flow
All-round flow is available, as well as 2-way to
4-way flows, so you can choose the most
suitable airflow pattern depending on location or L-shaped
room layout. 4-way flow 3-way flow 2-way flow

*For 3-way or 2-way flow installation, the sealing member for air discharge outlet
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. (option) must be used to close each unused outlet.

21 22
Indoor Unit Lineup

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Cassette (Compact Multi Flow) Type

FXFQ25LU / FXFQ32LU / FXFQ40LU FXZQ20M / FXZQ25M / FXZQ32M


FXFQ50LU / FXFQ63LU / FXFQ80LU FXZQ40M / FXZQ50M
FXFQ100LU / FXFQ125LU

360° airflow improves temperature distribution Quiet, compact, and designed for user comfort
and offers a comfortable living environment. Dimensions correspond with 600 mm x 600 mm
architectural module ceiling design specifications.
The industry’s first* Round Flow Ceiling Mounted
Cassette type offers 360° airflow with improved

Indoor Unit Lineup


Low operation sound level
temperature distribution. (dB(A))
4-way flow FXZQ-M 20/25 32 40 50
Round Flow
Sound level
(H/L) 32/29 33/29 36/30 41/34

Comfortable airflow

There are areas of There are much fewer


1 Wide discharge angle: 0° to 60°
uneven temperature. areas of uneven temperature. Auto swing
* As of April 2004, the release date for Japan.
The light weight unit at 19.5 kg for FXFQ25-50LU
models makes installation easy.
Drain pump is equipped as a 0° 0°
850 mm
standard accessory with a 850 mm
lift. 60°
60°
A modern sophisticated decoration panel has been
Fixed angles: 5 levels
applied, with a panel surface that has been treated with
a dirt-repellant coating. An antibacterial treatment that uses silver ions has
Treated surface Untreated surface been applied to the drain pan, preventing the growth
Dirt and
of slime, mould and bacteria that cause blockages 0° 0°
Resists grime • Condition after and odours. Drain pump is equipped as standard accessory with
soiling exposure to the
smoke of 600
750 mm lift.
cigarettes in 1 m
3
The horizontal louvres prevent dew condensation. 60° 60°
enclosed space.
Their non-flocking surfaces, which repel dirt, are *Angles can be also set on site to prevent drafts (0°-35°)
Control of the airflow rate can be selected from 3-step easy to clean. or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).
control. 750 mm
The air filter has an anti-mould and antibacterial 2 2-, 3-, and 4-way airflow patterns are available,
Low operation sound level (dB(A)) enabling installation in the corner of a room.
FXFQ-LU 25/32 40 50 63 80 100 125
treatment that prevents the growth of mould
Sound generated from dust or moisture that may adhere to
level
(HH/H/L)
30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 the filter.

Example of airflow patterns: All-round flow 4-way flow 3-way flow L-shaped 2-way flow
All-round flow is available, as well as 2-way to
4-way flows, so you can choose the most
suitable airflow pattern depending on location or L-shaped
room layout. 4-way flow 3-way flow 2-way flow

*For 3-way or 2-way flow installation, the sealing member for air discharge outlet
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. (option) must be used to close each unused outlet.

21 22
Indoor Unit Lineup

VRV Indoor Units

4-Way Flow Ceiling Suspended Type Ceiling Mounted Cassette (Double Flow) Type

FXCQ20M / FXCQ25M / FXCQ32M


FXUQ71A / FXUQ100A FXCQ40M / FXCQ50M / FXCQ63M
FXCQ80M / FXCQ125M

This slim and stylish indoor unit achieves


optimum air distribution, and can be installed Thin, lightweight, and easy to install in
without the need for ceiling cavity. narrow ceiling spaces
Unit body and suction panel

Indoor Unit Lineup


adopted round shapes and The thin unit (only 305 mm high) can be installed in a
realised a slim appearance ceiling space as narrow as 350 mm. All models feature a
design. The unit can be used compact design with a depth of only 600 mm.
for various locations such as
the ceilings with no cavity and
bare ceilings.
Flaps close automatically when 305 mm
the unit stops, which gives a
simple appearance.
(When a high-efficiency filter is attached, the unit's height is
Unified slim height of 198 mm 400 mm.)
for all models that gives the
unified impression even when 198 mm
models with different capacities Low operation sound level (dB(A))

are installed in the same area. FXCQ-M 20 25/32 40/50 63 80 125

Built-in electronic expansion valve eliminates the need Control of the airflow rate has been improved from Sound level
44/38
32/27 34/28 34/29 37/32 39/34
for a BEV unit, which improves flexibility of installation. 2-step to 3-step control. Auto airflow rate control can (H/L)

Current model New model be selected with wired remote controller BRC1E62.
Energy efficiency has been improved thanks to the
Designed with higher airflow suitable for high ceiling
adoption of a new heat exchanger with smaller
application up to 3 metres.
tubes, DC fan motor and DC drain pump motor.
BEV unit is BEV unit is Drain pump is equipped as a standard accessory, and the
needed not needed
lift height has been improved from 500 mm to 600 mm. Providing 2 different settings of standard and ceiling soiling Two types of optional high-efficiency filter are available
prevention, the auto swing mechanism realises even (65% and 95%, colourimetric method).
Depending on installation site requirements or room
With adoption of the individual flap control, airflow distribution of airflow and room temperature.
conditions, 2-way, 3-way and 4-way discharge
direction adjustment can be individually set for each air
patterns are available.
outlet. 5 directions of airflow and auto-swing can be A long-life filter (maintenance free up to one year*) is
selected with wired remote controller BRC1E62, which 4-way flow 3-way flow Drain pump is equipped as standard accessory with equipped as standard accessory.
realises the optimum air distribution. 600 mm lift. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Individual airflow direction example case


Position 0 Position 2
Major maintenance work can be performed by removing
600 mm the panel. A flat-type suction grille and a detachable
L-shaped 2-way flow
blade make cleaning easy.
Position 3 Swing

23 24
Indoor Unit Lineup

VRV Indoor Units Residential Indoor Units with connection to BP units

Floor Standing Duct Type Ceiling Mounted Cassette Type

FXVQ125M / FXVQ200M
FCQ35B / FCQ50B
FXVQ250M / FXVQ400M
FCQ60B / FCQ71B
FXVQ500M

Large air volume type for large spaces.


Flexible interior design for each tenant.
Large airflow type that fits for spacious areas such as factories
and large stores.

Various installations can be supported from full-scale duct

Indoor Unit Lineup


Option
connection airflow to direct airflow that allows for easy Signal receiver unit
Note: Remote controller Note: Wireless remote
installation. cables not included. Option controllers and signal
Cables should be receiver units are sold
obtained locally. as a set.
Full-scale duct connection airflow
allows for air conditioning evenly in
spacious areas.

Duct connection airflow type Specially designed for false ceilings


Adding the plenum chamber (option)
—for a smooth, modern interior finish
allows for simple operation with direct
airflow.
All models feature a decoration panel with the same Three convenient patterns for auto-swing operation
* Note that the operation sound increases by compact size and simple design for easier planning Standard
approximately 5 dB(A). of lighting systems and harmonising of interior décor.
Direct airflow type

The high static pressure type driven by the belt drive

950 mm
system allows for use of air discharge outlets in various Same for Draft prevention

shapes as well as long ducts. Highly flexible installation all models


is possible.

Design with high maintainability that allows major Decoration panel is optional
services and maintenance services to be performed at 950 mm Soiling prevention
the front.

A long-life filter (maintenance free up to one year*) is


equipped as a standard accessory. The indoor units weigh only 24 kg and require an
* 8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m3 installation space with a height of just 245 mm.
Drain pump is equipped as
A wide range of optional accessories are available such Min. 245 mm
as high-efficiency filters. standard with 750 mm. 750 mm

Outdoor air intake mode is All-fresh (using outdoor air only) system Return + Outdoor air mixed system
useable as an outdoor-air Outside
processing air conditioner. Outside Low operation sound level
Circulated air

Air
conditioning
Air (H/L) These models have the
conditioning
*When using the unit as an outdoor-air
processing unit, there are some FCQ35B FCQ50B FCQ60B FCQ71B power to provide a
restrictions. Strictly follow the restrictions
specified in the Engineering Data Book. comfortable airflow Max. 3.8 m
Outdoor air Outdoor air 33/29 dB (A) 33/29 dB (A) 35/30 dB (A) 35/30 dB (A)
introduction introduction even with a ceiling
* Air introduced from the outside and circulated air must be mixed in the
height of up to 3.8 m.
air conditioner primary side before introduction into the air conditioner.

31 32
Indoor Unit Lineup

Residential Indoor Units with connection to BP units

Ceiling Mounted Cassette (Compact Multi Flow) Type Ceiling Mounted Built-in Type

FFQ25B / FFQ35B
FBQ60B / FBQ71B
FFQ50B / FFQ60B

Option
Note: Remote controller
cables not included.
Cables should be
obtained locally.

Indoor Unit Lineup


Option
Note: Remote controller
Signal receiver unit Flexible air discharge unit to
fit various forms of space
Option Note: Wireless remote
cables not included. controllers and signal
Cables should be receiver units are sold
obtained locally. as a set.
The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab.
It also works with both flexible and ordinary ducts.
Quiet, compact, and designed for user comfort Standard installation examples
In crawl space With canvas bellows and air intake panel (sold separately) With high-efficiency filter
Designed to fit 600 mm wide ceiling grids Low draft performance is 6 4
2 Air conditioner
350 mm or more 2 Air conditioner 2 Air conditioner

designed for your comfort.


4 425 mm or more
6 540 mm or more
Horizontal Flow
575 mm Long-life filter 3 4 13 7
5 1 6
Air blow Long-life filter
3
Air intake 5 1

575 mm 45 mm
Air blow Air intake
5
Air intake
1

Less draught Air blow

Ceiling return Ceiling return with high-efficiency filter With ordinary ducts
286
mm 2 Air conditioner 2 Air conditioner
Ordinary duct Air conditioner Ordinary duct
540 mm or more
act (procured locally) (procured locally)
Comp e panel
450 mm or more
Comfortable across all areas
4
6
Air intake
tiv
6 Air intake 4 11 10
decora
11
Long-life filter 9 7 9 460 mm or more

Conditioned air is distributed Adjustable airflow angle to 5 8 8


Air intake
700 mm evenly by Auto-swing operation. suit all room conditions. Air blow
Air blow 5 8
Air blow

AUTO-SWING 5 direction Options 1 Decorative panel 4 Flexible duct 7 High-efficiency filter 10 Air discharge opening flange
700 mm 2 Air discharge opening adaptor 5 Air discharge grille 8 Inspection panel 11 Rear intake filter chamber
3 Canvas bellows and air intake panel 6 Air discharge chamber 9 Rear intake blocking pad 12 Branch duct
Standard 0 0
setting Auto-swing Settable to 5 different levels 13 Low-draft filter chamber
between 0 and 60 between 0 and 60
T-bar grid does not need to be cut. 60 60

Draft
To cope with the challenges of L-shaped or Drain pump is equipped as standard accessory with
Ceiling panel prevention
setting
0 0 U-shaped spaces, it is possible to install the air 250 mm lift.
Auto-swing Settable to 5 different levels
T-bar (Set on site) 35 between 0 and 35 35 between 0 and 35 discharge unit away from the main unit. This
Setting to extends the possibilities for coping with human
prevent
soiling of 25 25
gathering patterns or sun lighting. At the same 250 mm
Auto-swing Settable to 5 different levels
600 mm ceiling
between 25 and 60 between 25 and 60 time, different types of architectural space can be
600 mm (Set on site) 60 60

Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
kept comfortable.
Drain pump is equipped as standard
Low operation sound level (H/L) accessory with 750 mm lift.
FFQ25B FFQ35B FFQ50B FFQ60B Low operation sound level (H/L)

29.5/24.5 dB (A) 32/25 dB (A) 36/27 dB (A) 41/32 dB (A) 750 mm FBQ60B FBQ71B
L-shaped room U-shaped room Long room 41/35 dB (A) 41/35 dB (A)

33
31 34
32
Indoor Unit Lineup

VRV Indoor Indoor


Residential Units Units with connection to BP units

Slim Ceiling Mounted Duct Type Wall Mounted Type

700 mm width type


FDKS25EA / FDKS35EA FTKS25D / FTKS35D
900/1,1000 mm width type
FDKS25CA / FDKS35CA Standard accessory*
FDKS50C / FDKS60C
FTKS50B

FTKS50F / FTKS60F / FTKS71F


Standard accessory*
Standard accessory
Note: Remote controllers
other than the standard
accessory wireless remote
controller cannot be used.

Indoor Unit Lineup


Standard
Slim and smooth design accessory*

suits your shallow ceiling * Remote controllers other than the standard accessory wireless remote controller cannot be used.

Models in the FDKS-EA series are only 700 mm


in width and 21 kg in weight, so are easily
Low operation sound level (H/L/SL) Stylish flat panel harmonises with your interior décor
FDKS25 FDKS35 FDKS50 FDKS60
installed in limited spaces. Just 200 mm in height, Wall Mounted indoor units achieve quiet sound Titanium apatite is a photocatalytic material with
all models can be installed in rooms with as little 35/31/29 dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A) levels of 22 dB (A). high adsorption power. Titanium apatite also
(H/L/SL)
as 240 mm depth between the drop ceiling and effectively adsorbs and decomposes bacteria
ceiling slab, making them ideal for even shallow Home Leave Operation prevents large rises or FTKS25D FTKS35D FTKS50F FTKS60F FTKS71F
across its entire surface. The photocatalyst is
ceilings. falls in the indoor temperature by continuing 37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33 dB (A) 46/37/34 dB (A) activated simply by exposure to light.
operation* while you are sleeping or out of your
FDKS-EA
Great for home. This means that an air-conditioned Intelligent Eye with its infrared sensor
hotel use! welcome awaits when you wake or return. It also automatically controls air conditioner operation
means that the indoor temperature can quickly according to human movement in a room. When
return to your favourite comfort setting. there is no movement, it adjusts the temperature Air filter

* Home Leave Operation can be selected for any temperature from 18 to by 2˚C for energy savings. Catches dust

32˚C for cooling operation.


200 mm * Home Leave Operation function must be set using the remote controller
when going to sleep or leaving the house, and after waking up or returning
Only 700 mm home.
Titanium Apatite
FDKS25EA FDKS35EA FDKS25CA FDKS35CA Photocatalytic
Air-purifying Filter
Dimensions (H x W x D) 200 x 700 x 620 mm 200 x 900 x 620 mm Air discharge duct* Suspension bolt* Suction duct*
Air filter
Weight 21 kg 25 kg Air discharge grille*

Airflow rate (H) 8.7 m3/min 9.5 m3/min 10 m3/min These filters are not medical devices. Benefits
External static pressure 30 Pa 40 Pa
AIR When you are in the room When you go out such as the adsorption and decomposition of
3-D Airflow bacteria are only effective for substances that are
240 mm Chamber
combines Vertical collected on and in direct contact with the Titanium
Signal receiver wire Air suction
Length = 1,900 mm grille*
and Horizontal Apatite Photocatalytic Air-Purifying Filter.
AIR
Signal
receiver * Locally obtained parts

Notes:
Auto-Swing to Bacteria Removal Test
Option 1. To prevent an increase in operation noise, avoid circulate air to every Testing method: dropping method
installing the air suction grille directly below the
suction chamber. part of a room for Result certificate: No. 012553-1 and 012553-2
2. Grilles, piping connections, ducts, and installation Testing organisation: Japan Spinners Inspecting Foundation
parts should be obtained locally. Slim Ceiling uniform cooling of even
Suction grille (KDGF19A45)
Mounted Duct type FDKS models do not have
drain-up pumps.
large spaces.
3. The signal receiver unit must be located near the * This function is available for A uniform temperature
air suction inlet, because the unit includes a is achieved throughout
Signals from the wireless remote controller are sensor that detects room temperature.
FTKS50/60/71F.
the entire room.
transmitted to the signal receiver.

35 36
Specifications

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type Ceiling Mounted Cassette (Compact Multi Flow) Type
MODEL FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ240MVE FXZQ50MVE
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 1,900 2,400 3,100 3,900 4,800
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 2.2 2.8 3.6 4.5 5.6
Power consumption Cooling kW 0.031 0.031 0.041 0.080 0.095 0.095 0.194 0.219 Power consumption Cooling kW 0.073 0.076 0.089 0.115
Casing Galvanised steel plate Casing Galvanised steel plate
m3/min 12.5/11.5/10.0 12.5/11.5/10.0 14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0 m3/min 9/7 9.5/7.5 11/8 14/10
Airflow rate (H/M/L) Airflow rate (H/L)
cfm 441/406/353 441/406/353 512/459/388 777/618/477 830/653/477 830/688/530 1,165/918/671 1,218/971/741 cfm 318/247 335/265 388/282 493/353
Sound level(H/M/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35 Sound level 230 V, 50 Hz-
dB(A) 30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35
Dimensions (H×W×D) mm 246×840×840 288×840×840 (H/L) 240 V,50Hz

Machine weight kg 19 23 26 Dimensions (H×W×D) mm 286×575×575


Liquid (Flare) 6.4 9.5 Machine weight kg 18
Piping 6.4
Gas (Flare) mm 12.7 15.9 Liquid (Flare)
connections Piping
Drain I.D. 25×O.D. 32(VP25) Gas (Flare) mm 12.7
connections
Model BYCQ125B-W1 Drain VP20 (External Dia, 26/Internal Dia, 20)

Panel Colour Fresh white Model BYFQ60B8W1


(Option) Dimensions(H×W×D) mm 50×950×950 Panel Colour White (6.5Y9.5/0.5)
Weight kg 5.5 (Option) Dimensions(H×W×D) mm 55×700×700
Weight kg 2.7

Specifications
Ceiling Mounted Cassette (Round Flow) Type 4-way Flow Ceiling Suspended Type
MODEL FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1FXFQ125LUV1 MODEL FXUQ71AVEB FXUQ100AVEB
Power supply 1-phase, 220-240 V, 50 Hz Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 6,900 9,600
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 27,300 38,200
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 8.0 11.2
Power consumption Cooling kW 0.033 0.033 0.047 0.052 0.066 0.093 0.187 0.209 Power consumption Cooling kW 0.090 0.200
Casing Galvanised steel plate Casing colour Fresh white
m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5 m3/min 22.5/19.5/16 31/26/21
Airflow rate (HH/H/L) Airflow rate (H/M/L)
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794 cfm 794/688/565 1,094/918/741
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 Sound level (H/M/L) dB(A) 40/38/36 47/44/40
Dimensions (H×W×D) mm 246X840X840 288X840X840 Dimensions (H×W×D) mm 198×950×950
Machine weight kg 19.5 22 25 Machine weight kg 26 27
Liquid (Flare) 6.4 9.5 Liquid (Flare) 9.5
Piping Piping
Gas (Flare) mm 12.7 15.9 Gas (Flare) mm 15.9
connections connections
Drain VP25 (External Dia, 32/Internal Dia, 25) Drain VP20 (External Dia, 26/Internal Dia, 20)
Model BYCP125K-W1
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Panel Colour Fresh white • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(Option) Dimensions(H×W×D) mm 50X950X950 (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
Weight kg 5.5 During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5m, Level difference: 0m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5m downward from the unit centre.

37 38
Specifications

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type Ceiling Mounted Cassette (Compact Multi Flow) Type
MODEL FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ240MVE FXZQ50MVE
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 1,900 2,400 3,100 3,900 4,800
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 2.2 2.8 3.6 4.5 5.6
Power consumption Cooling kW 0.031 0.031 0.041 0.080 0.095 0.095 0.194 0.219 Power consumption Cooling kW 0.073 0.076 0.089 0.115
Casing Galvanised steel plate Casing Galvanised steel plate
m3/min 12.5/11.5/10.0 12.5/11.5/10.0 14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0 m3/min 9/7 9.5/7.5 11/8 14/10
Airflow rate (H/M/L) Airflow rate (H/L)
cfm 441/406/353 441/406/353 512/459/388 777/618/477 830/653/477 830/688/530 1,165/918/671 1,218/971/741 cfm 318/247 335/265 388/282 493/353
Sound level(H/M/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35 Sound level 230 V, 50 Hz-
dB(A) 30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35
Dimensions (H×W×D) mm 246×840×840 288×840×840 (H/L) 240 V,50Hz

Machine weight kg 19 23 26 Dimensions (H×W×D) mm 286×575×575


Liquid (Flare) 6.4 9.5 Machine weight kg 18
Piping 6.4
Gas (Flare) mm 12.7 15.9 Liquid (Flare)
connections Piping
Drain I.D. 25×O.D. 32(VP25) Gas (Flare) mm 12.7
connections
Model BYCQ125B-W1 Drain VP20 (External Dia, 26/Internal Dia, 20)

Panel Colour Fresh white Model BYFQ60B8W1


(Option) Dimensions(H×W×D) mm 50×950×950 Panel Colour White (6.5Y9.5/0.5)
Weight kg 5.5 (Option) Dimensions(H×W×D) mm 55×700×700
Weight kg 2.7

Specifications
Ceiling Mounted Cassette (Round Flow) Type 4-way Flow Ceiling Suspended Type
MODEL FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1FXFQ125LUV1 MODEL FXUQ71AVEB FXUQ100AVEB
Power supply 1-phase, 220-240 V, 50 Hz Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 6,900 9,600
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 27,300 38,200
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 8.0 11.2
Power consumption Cooling kW 0.033 0.033 0.047 0.052 0.066 0.093 0.187 0.209 Power consumption Cooling kW 0.090 0.200
Casing Galvanised steel plate Casing colour Fresh white
m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5 m3/min 22.5/19.5/16 31/26/21
Airflow rate (HH/H/L) Airflow rate (H/M/L)
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794 cfm 794/688/565 1,094/918/741
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 Sound level (H/M/L) dB(A) 40/38/36 47/44/40
Dimensions (H×W×D) mm 246X840X840 288X840X840 Dimensions (H×W×D) mm 198×950×950
Machine weight kg 19.5 22 25 Machine weight kg 26 27
Liquid (Flare) 6.4 9.5 Liquid (Flare) 9.5
Piping Piping
Gas (Flare) mm 12.7 15.9 Gas (Flare) mm 15.9
connections connections
Drain VP25 (External Dia, 32/Internal Dia, 25) Drain VP20 (External Dia, 26/Internal Dia, 20)
Model BYCP125K-W1
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Panel Colour Fresh white • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(Option) Dimensions(H×W×D) mm 50X950X950 (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
Weight kg 5.5 During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5m, Level difference: 0m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5m downward from the unit centre.

37 38
Specifications

VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type Ceiling Mounted Cassette (Compact Multi Flow) Type
MODEL FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ240MVE FXZQ50MVE
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 1,900 2,400 3,100 3,900 4,800
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 2.2 2.8 3.6 4.5 5.6
Power consumption Cooling kW 0.031 0.031 0.041 0.080 0.095 0.095 0.194 0.219 Power consumption Cooling kW 0.073 0.076 0.089 0.115
Casing Galvanised steel plate Casing Galvanised steel plate
m3/min 12.5/11.5/10.0 12.5/11.5/10.0 14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0 m3/min 9/7 9.5/7.5 11/8 14/10
Airflow rate (H/M/L) Airflow rate (H/L)
cfm 441/406/353 441/406/353 512/459/388 777/618/477 830/653/477 830/688/530 1,165/918/671 1,218/971/741 cfm 318/247 335/265 388/282 493/353
Sound level(H/M/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35 Sound level 230 V, 50 Hz-
dB(A) 30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35
Dimensions (H×W×D) mm 246×840×840 288×840×840 (H/L) 240 V,50Hz

Machine weight kg 19 23 26 Dimensions (H×W×D) mm 286×575×575


Liquid (Flare) 6.4 9.5 Machine weight kg 18
Piping 6.4
Gas (Flare) mm 12.7 15.9 Liquid (Flare)
connections Piping
Drain I.D. 25×O.D. 32(VP25) Gas (Flare) mm 12.7
connections
Model BYCQ125B-W1 Drain VP20 (External Dia, 26/Internal Dia, 20)

Panel Colour Fresh white Model BYFQ60B8W1


(Option) Dimensions(H×W×D) mm 50×950×950 Panel Colour White (6.5Y9.5/0.5)
Weight kg 5.5 (Option) Dimensions(H×W×D) mm 55×700×700
Weight kg 2.7

Specifications
Ceiling Mounted Cassette (Round Flow) Type 4-way Flow Ceiling Suspended Type
MODEL FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1FXFQ125LUV1 MODEL FXUQ71AVEB FXUQ100AVEB
Power supply 1-phase, 220-240 V, 50 Hz Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
kcal/h 2,400 3,100 3,900 4,800 6,100 7,700 9,600 12,000 kcal/h 6,900 9,600
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 Cooling capacity Btu/h 27,300 38,200
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 kW 8.0 11.2
Power consumption Cooling kW 0.033 0.033 0.047 0.052 0.066 0.093 0.187 0.209 Power consumption Cooling kW 0.090 0.200
Casing Galvanised steel plate Casing colour Fresh white
m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5 m3/min 22.5/19.5/16 31/26/21
Airflow rate (HH/H/L) Airflow rate (H/M/L)
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794 cfm 794/688/565 1,094/918/741
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 Sound level (H/M/L) dB(A) 40/38/36 47/44/40
Dimensions (H×W×D) mm 246X840X840 288X840X840 Dimensions (H×W×D) mm 198×950×950
Machine weight kg 19.5 22 25 Machine weight kg 26 27
Liquid (Flare) 6.4 9.5 Liquid (Flare) 9.5
Piping Piping
Gas (Flare) mm 12.7 15.9 Gas (Flare) mm 15.9
connections connections
Drain VP25 (External Dia, 32/Internal Dia, 25) Drain VP20 (External Dia, 26/Internal Dia, 20)
Model BYCP125K-W1
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Panel Colour Fresh white • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(Option) Dimensions(H×W×D) mm 50X950X950 (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
Weight kg 5.5 During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5m, Level difference: 0m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5m downward from the unit centre.

37 38