Vertical Struts

Design tensile force = 7.605 kN


Design compressive force = 2.2605 kN

Maximum length = 1372 mm

Effective length, lz = 1*L


lz = 1372 mm

The provided member is 25M circular pipe


The relevant properties of 40M circular pipe, (from HIPCO STRUCTURAL PIPES)
A= 3.11 sq.cm r= 1.08 cm
= 10.8 mm

lz/rz = 127.037

critical section = lz/rz = 127.037 < 180


OK

For fy = 250, curve a, l/r = 127.037 the design compressive stress is


fcd = 120 N/sq.mm
b/t = 10.53 < 15.7 Ԑ=1
OK
Semi compact

Design compressive strength,


Pd = Ae*fcd = 37.32 > 2.2605 kN
OK

Tensile Stress Check


Tensile strength of the section due to gross section yielding
Tdg = fy * Ag/ϒm0 = 70.68182 > 7.605 kN
OK

Inclined Struts

Design tensile force = 4.7415 kN


Design compressive force = 10.416 kN

Maximum length = 1296 mm

Effective length, lz = 1*L


lz = 1296 mm

The provided member is 25M circular pipe


The relevant properties of 40M circular pipe, (from HIPCO STRUCTURAL PIPES)
A= 3.11 sq.cm r= 1.08 cm
= 10.8 mm

lz/rz = 120.000

critical section = lz/rz = 120.000 < 180


OK

For fy = 250, curve a, l/r = 120.000 the design compressive stress is


fcd = 101 N/sq.mm
b/t = 10.53 < 15.7 Ԑ=1
OK
Semi compact

Design compressive strength,


Pd = Ae*fcd = 31.411 > 10.416 kN
OK

Tensile Stress Check


Tensile strength of the section due to gross section yielding
Tdg = fy * Ag/ϒm0 = 70.68182 > 4.7415 kN
OK

Hence, Provide the members with the following sections:


Member Section
Rafter 40M circular pipes
Principle Tie 40M circular pipes
Vertical Struts 25M circular pipes
Inclined Struts 25M circular pipes