Beruflich Dokumente
Kultur Dokumente
DE SAN MARCOS
FACULTAD DE QUÍMICA E INGENIERÍA QUÍMICA
INTEGRANTES:
FLORES FERNANDEZ GERSON 14070165
ORIHUELA ASTETE BARBARA CRISTINA 14070147
PALOMINO ZELAYA CLAUDIA 14070174
TORRES RIMEY MARIA JULIA 14070158
TURNO: 8am-2pm
GRUPO: A
2017
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
TABLA DE CONTENIDO
1.RESUMEN……………………………………………………………………………………3
2.INTRODUCCION………………………………………………………………………….....4
3.DISCUSIÓN HISTÓRICA…………………………………………………………………..5
4.PRINCIPIOS TEORICOS…………………………………………………………………….6
5.DETALLES EXPERIMENTALES ………………………………………………………….10
5.1.DESCRIPCIÓN DEL EQUIPO…………………………………………………..10
5.2 PROCEDIMIENTO EXPERIMENTAL………………………………………...11
6. TABLA DE DATOS EXPERIMENTALES………….……………………………………12
6.1.RESULTADOS…………………………………………………………………..18
8.DISCUSIÓN DE RESULTADOS………………………………………………………….24
9.CONCLUSIONES………………..…………………………………………………………25
10.RECOMENDACIONES………………………………………………………………….26
11.REFERENCIAS BIBLIOGRÁFICAS……………………………………………………27
12..APÉNDICE………………………………………………………………………………28
MÉTODO DE CÁLCULO………………………………………………………… 28
GRAFICOS………………………………………………………………………….33
UNMSM 2
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
I. RESUMEN
UNMSM 3
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
II. INTRODUCCIÓN
UNMSM 4
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 5
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
La conducción térmica está determinada por la ley de Fourier, que establece que el flujo
de transferencia de calor por conducción en un medio isótropo es proporcional y de sentido
contrario al gradiente de temperatura en esa dirección.
∂ Qx ∂T
= −KA
∂t ∂x
describe la distribución del calor (o variaciones de la temperatura) en una región a lo largo del
transcurso del tiempo. Para el caso de una función de tres variables en el espacio (x,y,z) y la
variable temporal t, la ecuación del calor es:
∂T ∂2 T ∂2 T ∂2 T
− α ( 2 + 2 + 2) = 0
∂t ∂x ∂Y ∂Z
UNMSM 7
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
Al no tomar en cuenta los gradientes de temperatura dentro del sólido, ya no es posible considerar
el problema desde dentro del marco de la ecuación de difusión de calor. En su lugar, la respuesta
de temperatura transitoria se determina realizando un balance global de energía en el sólido. Este
balance debe relacionar la velocidad de pérdida de calor en la superficie con la rapidez de cambio
de la energía interna.
El balance de energía en forma de calor es:
𝒒𝒄𝒐𝒏𝒗𝒆𝒄𝒄𝒊𝒐𝒏= 𝒒𝒂𝒄𝒖𝒎𝒖𝒍𝒂𝒄𝒊𝒐𝒏
𝑇(𝑡) − 𝑇∞ ℎ𝐴𝑠
ln =− 𝑡
𝑇𝑖 − 𝑇∞ 𝜌𝑉𝐶𝑝
𝑉
𝐿𝑐 =
𝐴𝑠
ℎ𝐿𝑐
𝐵𝑖 =
𝑘
Un número pequeño de Biot representa poca resistencia a la conducción del calor y, por tanto,
gradientes pequeños de temperatura dentro del cuerpo.
UNMSM 8
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
número Bi, más exacto es el análisis de los sistemas concentrados. En general se acepta que el
análisis de sistemas concentrados es aplicable si: 𝐵𝑖 ≤ 0.1
Cuando se satisface este criterio, las temperaturas dentro del cuerpo con relación a la de los
alrededores (es decir, 𝑇 − 𝑇∞ ) permanecen dentro de un margen de 5% entre sí, incluso para
configuraciones geométricas bien redondeadas como la de una bola esférica. Como consecuencia,
cuando 𝐵𝑖 ≤ 0.1, la variación de la temperatura con la ubicación dentro del cuerpo será ligera y,
de manera razonable, se puede considerar como si fuera uniforme. Los cuerpos pequeños, con
conductividad térmica alta son buenos candidatos para este tipo de análisis, en especial cuando
se encuentran en un medio sea un mal conductor del calor (como el aire en u otro gas) que esté
inmóvil.
Se define además, la cantidad adimensional Número de Fourier (tiempo adimensional)
𝛼𝑡
𝐹0 =
𝐿2
F0 : Modulo de Fourier
α: Es la difusividad térmica.
𝑡: Tiempo característico
𝐿: Es la longitud a través de la que la conducción de calor ocurre.
1 𝑇 − 𝑇∞ 𝑘
. ln =− 𝑡
𝐵𝑖 𝑇0 − 𝑇∞ 𝜌𝐶𝑝 𝐿2𝐶
1 𝑇−𝑇 𝑘
De donde al graficar 𝐵𝑖 . ln 𝑇 −𝑇∞ vs t se obtiene una recta cuya pendiente es − 𝜌𝐶 2 conociendo
0 ∞ 𝑝 𝐿𝐶
el Cp y la densidad del cuerpo a trabajar se puede hallar su conductividad.
UNMSM 9
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
V. DETALLES EXPERIMENTALES
3.1 EQUIPOS Y MATERIALES:
Un termómetro.
Un tanque con agua a temperatura constante.
Dos cilindros de cobre y aluminio. Ambas presentan un orificio central en la base
superior por la cual se introduce el termómetro digital.
Un cronómetro.
UNMSM 10
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 11
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
T.agua (°C) 20
TABLA N°2: Dimensiones de la barras de cobre, aluminio y acero
20 °C
PROPIEDADES
COBRE ALUMINIO ACERO
Densidad (kg/m3) 8933 2702 7930
Cp (J/kg k) 390 903 525
K (W/mK) 389 237 16,3
UNMSM 12
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 13
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 14
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 15
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 16
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 17
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
CILINDRO DE ALUMINIO
TIEMPO (s) 1°Iteración 2°Iteración
Ln[(T-T∞)/(To-T∞)]
Fo Fo
0 0 0.000 0.000
10 -0.687 8.481 8.468
20 -0.910 16.962 16.935
30 -1.097 25.443 25.403
40 -1.321 33.925 33.871
50 -1.477 42.406 42.339
60 -1.680 50.887 50.806
70 -1.796 59.368 59.274
80 -1.976 67.849 67.742
90 -2.160 76.330 76.210
100 -2.295 84.812 84.677
110 -2.392 93.293 93.145
120 -2.528 101.774 101.613
130 -2.661 110.255 110.081
140 -2.721 118.736 118.548
150 -2.894 127.217 127.016
160 -2.982 135.699 135.484
170 -3.092 144.180 143.952
180 -3.172 152.661 152.419
190 -3.259 161.142 160.887
200 -3.388 169.623 169.355
210 -3.497 178.104 177.823
220 -3.577 186.586 186.290
230 -3.711 195.067 194.758
240 -3.785 203.548 203.226
250 -3.893 212.029 211.694
260 -4.014 220.510 220.161
270 -4.081 228.991 228.629
280 -4.152 237.472 237.097
290 -4.357 245.954 245.565
300 -4.453 254.435 254.032
310 -4.453 262.916 262.500
320 -4.558 271.397 270.968
330 -4.676 279.878 279.435
340 -4.676 288.359 287.903
350 -4.809 296.841 296.371
360 -4.963 305.322 304.839
370 -4.963 313.803 313.306
380 -4.963 322.284 321.774
390 -5.146 330.765 330.242
400 -5.146 339.246 338.710
410 -5.369 347.728 347.177
420 -5.369 356.209 355.645
430 -5.657 364.690 364.113
440 -5.657 373.171 372.581
450 -5.657 381.652 381.048
UNMSM 18
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
CILINDRO DE COBRE
TIEMPO (s) 1°Iteración 2°Iteración
Ln[(T-T∞)/(To-T∞)]
Fo Fo
0 0.000 0.000 0.000
10 -0.403 9.702 9.700
20 -0.579 19.403 19.400
30 -0.768 29.105 29.100
40 -0.939 38.806 38.800
50 -1.100 48.508 48.500
60 -1.248 58.210 58.200
70 -1.406 67.911 67.900
80 -1.541 77.613 77.600
90 -1.674 87.314 87.300
100 -1.790 97.016 97.000
110 -1.899 106.718 106.700
120 -2.013 116.419 116.400
130 -2.127 126.121 126.100
140 -2.228 135.822 135.800
150 -2.325 145.524 145.500
160 -2.428 155.226 155.200
170 -2.530 164.927 164.900
180 -2.624 174.629 174.600
190 -2.721 184.330 184.300
200 -2.796 194.032 194.000
210 -2.930 203.734 203.700
220 -3.023 213.435 213.400
230 -3.094 223.137 223.100
240 -3.171 232.838 232.800
250 -3.266 242.540 242.500
260 -3.386 252.242 252.200
UNMSM 19
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 20
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
CILINDRO DE ACERO
TIEMPO (s) 1°Iteración 2°Iteración
Ln[(T-T∞)/(To-T∞)]
Fo Fo
0 0.000 0.000 0.000
10 -0.033 0.356 0.354
20 -0.102 0.711 0.709
30 -0.199 1.067 1.063
40 -0.317 1.423 1.418
50 -0.417 1.779 1.772
60 -0.530 2.134 2.126
70 -0.627 2.490 2.481
80 -0.732 2.846 2.835
90 -0.875 3.201 3.190
100 -0.969 3.557 3.544
110 -1.061 3.913 3.898
120 -1.152 4.268 4.253
130 -1.249 4.624 4.607
140 -1.321 4.980 4.962
150 -1.418 5.336 5.316
160 -1.500 5.691 5.670
170 -1.580 6.047 6.025
180 -1.662 6.403 6.379
190 -1.791 6.758 6.734
200 -1.832 7.114 7.088
210 -1.946 7.470 7.442
220 -2.027 7.826 7.797
230 -2.093 8.181 8.151
240 -2.163 8.537 8.506
250 -2.239 8.893 8.860
260 -2.355 9.248 9.214
270 -2.422 9.604 9.569
280 -2.501 9.960 9.923
290 -2.564 10.315 10.278
300 -2.624 10.671 10.632
310 -2.704 11.027 10.986
320 -2.764 11.383 11.341
330 -2.818 11.738 11.695
340 -2.876 12.094 12.050
350 -2.948 12.450 12.404
360 -3.014 12.805 12.758
370 -3.084 13.161 13.113
380 -3.147 13.517 13.467
390 -3.214 13.872 13.822
400 -3.272 14.228 14.176
410 -3.348 14.584 14.530
420 -3.448 14.940 14.885
430 -3.521 15.295 15.239
440 -3.599 15.651 15.594
450 -3.662 16.007 15.948
460 -3.730 16.362 16.302
470 -3.828 16.718 16.657
480 -3.880 17.074 17.011
490 -3.936 17.430 17.365
500 -4.025 17.785 17.720
UNMSM 21
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
UNMSM 22
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
De la Tabla Nº10 se obtiene que: la barra de cobre una conductividad térmica fue
de 387.93 W/m.K, para la barra de aluminio fue de 237,62 W/m.K y para la barra
de acero fue de 16,88 W/m.K, arrojando un % desviación de 0,27%, 0,26% y 3,56%
para el cobre, aluminio y acero ,respecto a los valores de tablas. Observamos que
la desviación es relativamente pequeño, las precisiones de nuestros datos se
deben a que no hubo ninguna perturbación en el fluido, es decir se logró la
convección libre.
UNMSM 23
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
VIII. CONCLUSIONES
La conductividad térmica del cobre fue de 387.93 W/m.K con un porcentaje de
desviación de 0.27 % respecto al valor publicado de 389 W/m.K.
UNMSM 24
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
IX. RECOMENDACIONES
Una condición importante para el desarrollo de la experiencia es tener el
baño de agua, sin turbulencia, con lo cual consideraremos que la
transferencia de calor se realiza a través de convección libre.
Llenar adecuadamente el orificio del cilindro con aceite, con el fin de realizar
buenas lecturas de temperatura, se debe de evitar que ingrese agua a la
parte central del cilindro e interfiera con las medidas de temperatura.
Calentar las barras hasta una temperatura adecuada que nos permita
obtener una buena gráfica Ln [(T-T)/ (To-T)] versus t. con aproximación
lineal.
UNMSM 25
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
X. BIBLIOGRAFÍA
UNMSM 26
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
T (0) =105,9 °C
𝑇 − 𝑇𝛼 105,9 − 20
[ ]= =1
𝑇0 − 𝑇𝛼 105,9 − 20
T (10) =63,2 °C
𝑇 − 𝑇𝛼 63,2 − 20
[ ]= = 0.5032
𝑇0 − 𝑇𝛼 105,9 − 20
T (20) =54,6°C
𝑇 − 𝑇𝛼 54,6 − 20
[ ]= = 0.4024
𝑇0 − 𝑇𝛼 105,9 − 20
De la misma manera se calculan los Ln( ) para todos los datos ,los resultados se
encuentran en la Tabla N°6
𝑇−𝑇𝛼
Luego se gráfica 𝐿𝑛 [𝑇0−𝑇𝛼] vs t(s) , ver Grafico Nº 1
UNMSM 27
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
𝑇 − 𝑇∞
𝐿𝑛( )
𝑇0 − 𝑇∞
t (s)
𝑇 − 𝑇𝛼 ℎ𝑆
𝐿𝑛 [ ] = −[ ] 𝑥𝑡
𝑇0 − 𝑇𝛼 𝐶𝑝𝑉
𝑇 − 𝑇𝛼 ℎ𝑆
𝐿𝑛 [ ] 𝑣𝑠 𝑡 𝑙𝑎 𝑝𝑒𝑛𝑑𝑖𝑒𝑛𝑡𝑒 𝑠𝑒𝑟𝑎 − [ ]
𝑇0 − 𝑇𝛼 𝐶𝑝𝑉
Donde:
h = coeficiente de convección (W/m2 s)
ρ=densidad de material de la barra (kg/m3)
Cp=capacidad calorífica del material (J/kg K)
V =Volumen de la barra (m3)
S= Área superficial de la barra (m2)
2𝜋(0.05𝑚)2
𝑆= + 𝜋(0.05𝑚)(0.151𝑚)
4
𝑆 = 0.0276 𝑚2
UNMSM 28
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
Volumen de la barra:
𝜋𝐷 2
𝑉= 𝐿
4
𝜋(0.05𝑚)2
𝑉= ∗ 0.151𝑚
4
𝑉 = 2.96𝑥10−4 𝑚3
𝑉 2.96𝑥10−4 𝑚3
( ) = = 0.011𝑚
𝑆 𝐴𝑙 0.0276𝑚2
Reemplazando en (1)
ℎ
0.0105𝑠 −1 =
𝐽 𝐾𝑔
(903 𝐾𝑔 − 𝐾 ) (2702 3 ) (0.011𝑚)
𝑚
𝑊
ℎ = 274.749 𝑚2 𝐾
Se sabe que:
ℎ𝑥𝑆 ℎ 𝑥 (𝑉⁄𝑆) 𝑘𝑥𝑡
=[ ]𝑥 [ ]
𝜌 𝑥 𝐶𝑝 𝑥 𝑉 𝑘 𝜌 𝑥 𝐶𝑝 𝑥 (𝑉⁄𝑆)2
Donde:
𝑘 ℎ 𝑥 (𝑉⁄𝑆)
𝜌 𝑥 𝐶𝑝
=𝑎 y 𝐵𝑖𝑜𝑡 = 𝐵𝑖 = 𝑘
Entonces:
ℎ 𝛼
[ ] = 𝐵𝑖 𝑥
𝑉 (𝑉 ⁄ 𝑆)2
𝜌 𝑥 𝐶𝑝 𝑥 ( 𝑆 )
Como:
𝑇 − 𝑇𝛼 ℎ𝑆
𝐿𝑛 [ ] = −[ ] 𝑥𝑡
𝑇𝑜 − 𝑇𝛼 𝐶𝑝𝑉
𝑇 − 𝑇𝛼 𝛼
𝐿𝑛 [ ] = − 𝐵𝑖 𝑥 𝑥𝑡
𝑇𝑜 − 𝑇𝛼 (𝑉⁄𝑆)2
𝑇−𝑇𝛼
Por lo que al final se obtiene: 𝐿𝑛 [𝑇0−𝑇𝛼] = − 𝐵𝑖 . 𝐹𝑜
UNMSM 29
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
𝑇−𝑇𝛼
Al graficar: 𝐿𝑛 [𝑇0−𝑇𝛼] 𝑣𝑠. 𝐹𝑜, la pendiente es −𝐵𝑖
𝑉
ℎ. ( 𝑆 )
𝐵𝑖 =
𝐾𝑎𝑠𝑢𝑚𝑖𝑑𝑜
𝑊 0.000296𝑚3
274.749 ( )
𝑚2 𝐾 0.0276 𝑚2
𝐵𝑖 =
𝑊
238 𝑚 𝐾
𝐵𝑖 = 0.0124
𝐾𝑔 𝐽
Tenemos como dato teórico: 𝜌 = 2702 𝑚3 y 𝐶𝑝 = 903 𝑘𝑔 𝐾
Reemplazando datos:
𝑊
238
𝛼= 𝑚𝐾
𝐾𝑔 𝐽
2702 .903
𝑚3 𝑘𝑔 𝐾
𝛼 = 0.00009754
𝛼. 𝑡
𝐹𝑜 =
𝑉 2
(𝑆 )
Fo= 0,84811604 .t
Donde t: tiempo
𝑇−𝑇𝛼
Graficando Fo vs. 𝐿𝑛 [𝑇 ]
𝑜 −𝑇𝛼
UNMSM 30
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
De la tabla Nº 7 se obtiene:
𝑉
ℎ (𝑆 )
𝐵𝑖 =
𝑘𝑒𝑥𝑝𝑒𝑟𝑖𝑚𝑒𝑛𝑡𝑎𝑙
𝑊
𝑘𝑒𝑥𝑝𝑒𝑟𝑖𝑚𝑒𝑛𝑡𝑎𝑙 = 237,6234𝑚 𝐾
𝑊
Continuando con la iteración, obtenemos 𝑘𝑒𝑥𝑝𝑒𝑟𝑖𝑚𝑒𝑛𝑡𝑎𝑙 = 237,6234
𝑚𝐾
( %desviación=0 con respecto a un 𝑘𝑎𝑠𝑢𝑚𝑖𝑑𝑜 = 237,6234 )
237 − 237,6234
% desviacion = | | . 100%
237
% desviacion = 0.263
UNMSM 31
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
XII. GRÁFICAS
PARA EL ALUMINIO:
GRÁFICA N°1
Determinacion de la pendiente
0.000
0 50 100 150 200 250 300
-1.000
Ln[(T-T∞)/(To-T∞)]
y = -0,0105x - 1,2734
-2.000 R² = 0,9977
-3.000
-4.000
-5.000
tiempo(s)
GRÁFICA N°2
Primera iteración Fo
0.000
-0.500 0 50 100 150 200 250
Ln[(T-T∞)/(To-T∞)]
-1.000
-1.500
-2.000
y = -0,0124x - 1,2734
-2.500 R² = 0,9977
-3.000
-3.500
-4.000
-4.500
UNMSM 32
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
GRÁFICA N°3
segunda iteración Fo
0.000
0 50 100 150 200 250
Ln[(T-T∞)/(To-T∞)]
-1.000
-2.000
-5.000
PARA EL COBRE
GRÁFICO N°4
Determinación de la pendiente
0.0000
Ln[(T-T∞)/(To-T∞)]
-1.0000
-1.5000
y = -0.0097x - 0.8582
-2.0000 R² = 0.9983
-2.5000
-3.0000
-3.5000
tiempo(s)
UNMSM 33
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
GRÁFICO N°5
Primera iteración Fo
0.000
0 50 100 150 200 250 300
-0.500
Ln[(T-T∞)/(To-T∞)]
-1.000
y = -0.01x - 0.8582
-1.500
R² = 0.9983
-2.000
-2.500
-3.000
-3.500
GRÁFICO N°6
Segunda iteración Fo
0.000
Ln[(T-T∞)/(To-T∞)]
-1.000
y = -0.01x - 0.8582
-1.500 R² = 0.9983
-2.000
-2.500
-3.000
-3.500
UNMSM 34
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
PARA EL ACERO:
GRÁFICO N°7
Determinación de la pendiente
0.000
Ln[(T-T∞)/(To-T∞)]
-1.500
-2.000
-2.500
timpo(s)
GRÁFICO N°8
Primera iteración Fo
0.000
Ln[(T-T∞)/(To-T∞)]
0 1 2 3 4 5 6 7 8 9
-0.500
-1.000
-1.500
y = -0.2474x - 0.0917
R² = 0.999
-2.000
-2.500
UNMSM 35
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
GRÁFICO N°9
Segunda iteración Fo
0.000
0 2 4 6 8 10
Ln[(T-T∞)/(To-
-0.500
T∞)]
-2.000
-2.500
(T - T∞)/(To - T∞) vs t
1
0.9
0.8
0.7
(T-T∞)/(To-T∞)
0.6
0.5 ACERO
0.4 ALUMINIO
0.3 COBRE
0.2
0.1
0
0 100 200 300 400 500 600 700
Tiempo(s)
UNMSM 36
Conductividad
LABORATORIO DE INGENIERIA QUIMICA 1
Térmica
Asumir valor de
conductividad térmica:
𝑘𝑎𝑠𝑢𝑚𝑖𝑑𝑜
Calcular el número de
Fourier a partir del valor de
𝑘𝑎𝑠𝑢𝑚𝑖𝑑𝑜
Fo =f(t)
𝑇−𝑇𝛼
Graficar Fo vs. 𝐿𝑛 [𝑇 −𝑇𝛼]
𝑜
Hallamos la pendiente = -
Bi
Calculamos el valor de
𝑘𝑒𝑥𝑝𝑒𝑟𝑖𝑚𝑒𝑛𝑡𝑎𝑙
NO
𝑘𝑎𝑠𝑢𝑚𝑖𝑑𝑜 SI
= 𝑘𝑒𝑥𝑝𝑒𝑟𝑖𝑚𝑒𝑛𝑡𝑎𝑙
UNMSM 37