PIPEMILL - Piping Engineering, Design and Analysis

Version: 3.02b Full Run REGISTERED TO PARNINGOTAN BUTAR-BUTAR


PUMP NOZZLE LOADS EVALUATION TO API 610 (11th. Edition)
____________________________________________________________________________________________________________

Calculation by: ____________________ Checked by: ______________________ Sunday,Apr 1,2018

File Name: e:\Examples\API example F4.1.1.eqp

PUMP TYPE: FRONT SUCTION, TOP DISCHARGE.


Project / Description: Validation calc ref API 610 10th Edition

Calculation Details: Sample calc F 4 1 1

SUCTION: 12 in. (nom.) Stress Iso. Suction Data Point 100

DISCHARGE: 12 in. (nom.) Stress Iso. Discharge Data Point 200

API Factor applied to allowable loads: 2.00

Diagram shows LOCAL AXIS system


GLOBAL AXIS System in accordance with API 610 11th. Edition.

ORIENTATION relative to GLOBAL axis: Suction nozzle is: In 'X' plane


Vector FROM suction nozzle TO pump centre: -- X

__________________________________________________________________________________________________

Para. F.1.2.1: VECTORS AND LOADS: (Vectors are FROM the nozzle centre TO the pump centre.)

Standard API allowable loads (where applied) are extracted from table 2-1B and converted to SI units.
SUCTION: Vector X Vector Y Vector Z Force X Force Y Force Z Moment X Moment Y Moment Z
mm. mm. mm. N. N. N. Nm. Nm. Nm.

GLOBAL AXIS: -267 0 0 12900 -8852 0 -1356 -7458 4879

LOCAL AXIS: -267 0 0 12900 0 -8852 -1356 -4879 -7458

Table 4 allowable loads x factor 2.00 16012.8 13344. 10675.2 12204. 5966.4 9220.8

Status: - ok - - ok - - ok - - ok - - ok - - ok -

DISCHARGE: Vector X Vector Y Vector Z Force X Force Y Force Z Moment X Moment Y Moment Z
mm. mm. mm. N. N. N. Nm. Nm. Nm.

GLOBAL AXIS: -381 -311 7117 8674 445 678 -4882 3390

LOCAL AXIS: 0 311 -381 7117 -445 8674 678 -3390 -4882

Table 4 allowable loads x factor 2.00 13344. 10675.2 16012.8 12204. 5966.4 9220.8

Status: - ok - - ok - - ok - - ok - - ok - - ok -

__________________________________________________________________________________________________

Para. F.1

F1 = (FRSa / 1.5 FRSt4) + (MRSa / MRSt4) <= 2.00 F1 = 1.63 Within Allowable

F2 = (FRDa / 1.5 FRDt4) + (MRDa / MDSt4) <= 2.00 F2 = 1.13 Within Allowable

__________________________________________________________________________________________________

Para. F.1

F3 = 0.75 Fn (FRSt4 +FRDt4) > FRCa F3 = 34694.4 FRCa = 20022.7 Within Allowable

F4 = Fn (MYSt4 + MYDt4)^0.5 > MYCa F4 = 11932.8 MYCa =- 3193.9 Within Allowable

F5 = 0.75 Fn (MRSt4 + MRDt4) > MRCa F5 = 24814.8 MRCa = 11091.8 Within Allowable

Complies with para's F1, using the specified 'Fn' value. LOADS ARE ACCEPTABLE.

End of calculation

Das könnte Ihnen auch gefallen