Sie sind auf Seite 1von 2

Total No. of Questions : 8] [Total No.

of Pages : 2
[3964]-115
P1210
B.E. (Civil)
ADVANCED STRUCTURAL DESIGN
(2003 Course) (Elective - II) (401007) (Sem. - II)
Time : 3 Hours] [Max. Marks :100
Instructions to the candidates:
1) Attempt Q. 1 or Q. 2, Q. 3 or Q. 4 from Section I and Q. 5 or Q. 6, and Q. 7 or
Q. 8 from Section II.
2) Answers to the two sections should be written in separate answer books.
3) Neat diagram must be drawn wherever necessary.
4) Figure to the right indicates full marks.
5) Assume suitable data, if necessary.
6) Use of cell phone is prohibited in the examination hall.
7) Use of electronic pocket calculator, steel table and relevant IS code is
allowed.
SECTION - I
Q1) Select suitable configuration of the truss and determine the maximum
compressive and tensile force in the leg at the base for a 40 m microwave
antenna tower is to be built near Pune. The terrain at the location is a level
ground. It has to carry a 2.5 m diameter hemispherical antenna disc at the top.
[25]
a) Width at the top of tower = 3m
b) Width of tower at bottom = 5m
c) Weight of platform at top = 0.75 kN/m2
d) Weight of railing at top = 0.25 kN/m
e) Weight of ladder and cage = 0.50 kN/m
f) Weight of antenna disc and fixture = 10 kN
g) Self weight of truss = 6 kN/m
h) Terrain category II and class of building B.
OR
Q2) Two channel sections without bent lips 200 mm × 50 mm and 2.5 mm thick
are connected with webs to act as beam. The effective span of a simply
supported beam is 8 m. The beam is laterally supported throughout its length.
Determine the maximum uniformly distributed load inclusive of self weight
which can be supported by the beam. Assume f y = 232 N/mm 2 and
Ix = 2 x 390.307 x 104 mm4. [25]
P.T.O.
Q3) Design a hoarding board of size 4 m x 8 m, with minimum height from ground
= 3.8 m. Take basic wind velocity in the area as 40 m/s. Try alternative support
systems design the anchor block. [25]
OR
Q4) Design an open web (castellated beam) for a span of 16.2 m. The dead load
coming on roofing is 1 kN/m2 and live load on the roof is 1.8 kN/m2. Calculate
the spacing of the beam and check for shear and deflection. Adopt suitable
pattern of castellation and adjust the section such that overall depth of section
should not exceed 900mm. Assume fy = 250 Mpa. [25]

SECTION - II
Q5) A simply supported rectangular R C grid floor is 12 m x 15 m with centre to
centre spacing of grid 1.5 m in both the directions. Take live load = 3kN/m2
and floor finish = 1.2 kN/m2. Use M20 grade of concrete and Fe500 grade of
steel. Draw the details of the reinforcement in beams and slab. [25]
OR
Q6) Design simply supported circular slab of 6 m diameter, subjected to service
live load of 4.5 kN/m2 and floor finish of 1 kN/m2. Use M20 grade of concrete
and Fe415 grade of steel. Draw the reinforcement details. [25]

Q7) Design a counterfort retaining wall for the following data.


Height of wall above ground level = 6 m
Safe bearing capacity of soil = 160 kN/m2
Angle of repose = 30º
Unit weight of soil = 16000 N/m3
Spacing of counterfort = 3m
Coefficient of friction between soil and concrete = 0.5
Use M20 grade of concrete and Fe415 grade of steel. Draw the reinforcement
details. [25]
OR
Q8) Design an interior panel of size 6 m x 6 m of a flat slab with suitable drop to
support a live load of 4000 N/m2. The slab is provided with floor finish of
1000 N/m2. The floor system is supported by columns of size 500 mm x 500
mm. Floor to floor distance is 4 m. Use M20 grade of concrete and Fe415
grade of steel. Draw the reinforcement details. [25]

E E E
[3964]-115 2

Das könnte Ihnen auch gefallen