(0) MAIN MENU
NO. Parameter Range Default Modified Remark
1 PUMPING UNIT RUNNING INFORMATION
2 SURFACE REALTIME DYNAGRAPH CARD
3 DOWNHOLE REALTIME DYNAGRAPH CARD
4 VIEW DATA
5 ALARM STATUS
6 PROGRAMMING
7 BASIC PUMP CARD REF
8 QUICK START CONFIGURATION
9 OPERATION HELP
(0) MAIN MENU --> (1) PUMPING UNIT RUNNING INFORMATION
NO. Parameter Range Default Modified Remark
Pumping unit State: Read Only
Elasped In State: Read Only
System Control: Read Only
Remaining Downtime: Read Only
Run Time Today: Read Only
Run Time Yesterday: Read Only
Cycles Yesterday: Read Only
Balance: Storkes: SPM Read Only
Fillage Set: Cur: % Read Only
Frequency Set: Cur: Hz Read Only
(0) MAIN MENU --> (2) SURFACE REALTIME DYNAGRAPH CARD
NO. Parameter Range Default Modified Remark
0 Arrow SetPt Load Set / Fill Set 20.00Klbs/70% Move Load Set/Fill Set cursor with Up/Dn/Lt/Rt arrows
Allowed Min Load -
1 Load Set 20.00Klbs Load value of intermittent pumping set point
Allowed Peak Load
2 Fill Set 0- 99 70% Displacement percentage of intermittent pumping set point
3 Load Span 0 - Allowed Peak Load 0.00Klbs Pump-off judging threshold value
Allowed Min Load - Rated
4 Peak Load-Allowed 50Klbs 30Klbs High load alarm
Rod Load
Allowed Min Load - Rated
5 Peak Load-Present 0.00Klbs
Rod Load
6 Min Load-Allowed 0 - Allowed Peak Load 0.00Klbs Low load alarm
7 Min Load-Present 0 - Allowed Peak Load 0.00Klbs
8 Fillage READ ONLY %
9 Strokes READ ONLY SPM
(0) MAIN MENU --> (3) DOWNHOLE REALTIME DYNAGRAPH CARD
10 Arrow SetPt Fill Set / Load Set 70% / 35% Move Fill Set / Load Set cursor with Up/Dn/Lt/Rt arrows
11 Fill Set 0 - 99 70% Position percentage of intermittent pumping set point
12 Load Set 0 - 99 35% Load percentage of intermittent pumping set point
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (1) Dynagraph Cards
1 Historical Dynagraph Cards Read Only
2 Pump Up Dynagraph Cards Read Only
3 Shutdown Dynagraph Cards Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (2) Power Cards
1 Realtime Power Cards Read Only
2 Historical Power Cards Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (3) Cycle Run and Idle Time List
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (4) Daily Run Times List
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (5) Daily Run Ratio Plot
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (6) Daily Production Plot
(0) MAIN MENU --> (4) VIEW DATA --> (1) Pumping Unit Running Information --> (7) Historical Data Export
Data Export No Read Only Insert Disk and Change to YES
Export Status 0-100% Read Only Progress Bar (0-100%)
Messages: Read Only The disk Is Extracted
Messages: Read Only The disk Is Inserted
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (1) Pressure Transmitter Status
CASING Pressure PSI Read Only
TUBING Pressure PSI Read Only
FLOWLINE Pressure PSI Read Only
AI6 PSI Read Only
AI7 PSI Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (2) CASING Pressure Plot
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (3) TUBING Pressure Plot
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (4) FLOWLINE Pressure Plot
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (5) AI6 Pressure Plot
(0) MAIN MENU --> (4) VIEW DATA --> (2) Pressure Transmitter Information --> (6) AI6 Pressure Plot
(0) MAIN MENU --> (4) VIEW DATA --> (3) Controller Aux I/O Status --> (1) Analog Input & Analog Output Status
AI0 mV Read Only Load Cell
AI1 V Read Only Inclinometer (Not Used)
AI2 mA Read Only
AI3 mA Read Only CASING Pressure
AI4 mA Read Only
AI5 mA Read Only FLOWLINE Pressure
AI6 mA Read Only
AI7 mA Read Only
AO0 mA Read Only
AO1 V Read Only
AO2 mA Read Only
AO3 V Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (3) Controller Aux I/O Status --> (2) Digital Input Status
DI0 OPEN / CLOSE RPM Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI1 OPEN / CLOSE HAND Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI2 OPEN / CLOSE AUTO Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI3 OPEN / CLOSE CRANK Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI4 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI5 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI6 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI7 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI8 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI9 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI10 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI11 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI12 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI13 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI14 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI15 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI16 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
DI17 OPEN / CLOSE Read Only Digital Inputs are Active LOW (0V = CLOSE)
(0) MAIN MENU --> (4) VIEW DATA --> (3) Controller Aux I/O Status --> (3) Digital Output Status
DO0 OPEN / CLOSE Read Only
DO1 OPEN / CLOSE Read Only
DO2 OPEN / CLOSE Read Only
DO3 OPEN / CLOSE Read Only
DO4 OPEN / CLOSE Read Only
DO5 OPEN / CLOSE Read Only Pump Fault
DO6 OPEN / CLOSE Read Only
DO7 OPEN / CLOSE Read Only
DO8 OPEN / CLOSE Read Only
DO9 OPEN / CLOSE Read Only
DO10 OPEN / CLOSE Read Only
DO11 OPEN / CLOSE Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (4) VSD Running Information --> (1) VSD Status Screen
VSD Comm Status: Read Only
Set Freq: Hz Read Only
Output Freq: Hz Read Only
Bus Volt: V Read Only
Temperature: % Read Only
Output Volt: V Read Only
Output Curr: A Read Only
Output Power: % Read Only
Output Power: kW Read Only
Output Power: HP Read Only
(0) MAIN MENU --> (4) VIEW DATA --> (4) VSD Running Information --> (2) VSD Output Frequency Plot
(0) MAIN MENU --> (4) VIEW DATA --> (4) VSD Running Information --> (3) VSD Output Current Plot
(0) MAIN MENU --> (4) VIEW DATA --> (4) VSD Running Information --> (4) VSD Output Voltage Plot
(0) MAIN MENU --> (4) VIEW DATA --> (4) VSD Running Information --> (5) VSD Temperature Plot
(0) MAIN MENU --> (5) ALARM STATUS--> (1) Active Alarms
(0) MAIN MENU --> (5) ALARM STATUS--> (2) Historical Alarms
(0) MAIN MENU --> (5) ALARM STATUS--> (3) Alarm Reset
Reset Alarms No
Clear Alarms No
(0) MAIN MENU --> (6) PROGRAMMING --> (1) System Parameters
Date (mm-dd-yy) Set to Kuwait Date
Time (hh:mm:ss) Set to Kuwait Time
Background Color White-Black White
Controller Address 1
Factory Default No
(0) MAIN MENU --> (6) PROGRAMMING --> (2) Pumping Unit Parameters
C-1280D-365-
8 Pumping Unit Model * C-114-119-100 C-114-119-100
240
9 Stoke Length * 240 100 Select rated stroke of the pumping unit on site
10 Tubing Inside Diameter 0-30.000 2.440in 2.992 Set tubing inside diameter
11 Downhole Pump Diameter * 0-30.000 1.250in 2.5 Set downhole pump diameter
12 Downhole Pump Efficiency * 0-99 50% 90% Set correction factor of production calculation
(0) MAIN MENU --> (6) PROGRAMMING --> (3) KOC Tag System Parameters
VSD TAG Number: 723-14-0-0100 Well Block - VSD - GM - Pattern No. - 0 - Contractor Well Numer
Speed Indication: Hz VFD Output Frequency
Running / Stop Indication 0/1 Running = 1 / Stop = 0
Available Indication 0/1 Available = 1
Remote Indication 0/1 Remote = 1
Emergency Stop Indication 0/1 Emergncy Stop = 1
(0) MAIN MENU --> (6) PROGRAMMING --> (4) End Devices Parameters --> (1) Rod Load Cell Parameters
Output Voltage: 1-2 2mV/V 2mV/V Set the resolution ratio of load cell
Rated Rod Load 1 - 100 50Klbs% 30Klbs Set the rated load of the load cell
(0) MAIN MENU --> (6) PROGRAMMING --> (4) End Devices Parameters --> (2) Position Transducer Parameters
RPM/Crank-
Position Transducer Type * Hall-Effect / Inclinometer Hall-Effect Select inclinometer model
Beam
Crank at Top /
Crank Sensor Location * Crank at Top Crank at Bottom The installation position of crank hall effect sensor
Crank at Bottom
Crank Sensor Adjustment Dir * Forward / Backward Forward Direction adjustment of crank hall effect sensor
Hall-Effect Adjustment Angle * 0.0 - 90.0° 0 Zero point offset angle of crank hall effect sensor
(0) MAIN MENU --> (6) PROGRAMMING --> (5) Controller AUX I/O Programming --> (1) Analog Input Programming
CASING/TUBING /
03 CASING Name
04 TUBING FLOWLINE / AI6 / AI7 AI3 Val: 600/0; LMT 600/0, Action NONE
05 FLOWLINE VAL- H VAL- L ~ 9999 3000PSI AI5 Val: 600/0; LMT 600/0, Action NONE
06 AI6 VAL- L 0 ~ VAL- H 0PSI
07 AI7
LMT-H LMT-L ~ VAL- H VAL- H PSI
LMT-L 0 ~ LMT-H VAL- L PSI
Action NONE / MALF / STOP NONE NONE
(0) MAIN MENU --> (6) PROGRAMMING --> (5) Controller AUX I/O Programming --> (2) Digital Input Programming
DI4 Name DI4~DI17 Channel name can be user-defined.
~ Alarm_State Closed / Open Closed Alarm status configuration
DI17 Action NONE/ MALF /STOP NONE Alarm action configuration
(0) MAIN MENU --> (6) PROGRAMMING --> (6) Pumping Unit Controlling Parameters --> (1) Pumping Unit Operating Parameters
Controller RPC/VSD/SA RPC VSD Must correspond to oilfield application.