Beruflich Dokumente
Kultur Dokumente
Carbon
44 monoxide 2008 / USA EE ME L
release
Carbon
48 monoxide 2001 / Canada EE ME L
release
8 Casualty 1989 / HK HE ME L
15 Collapse of
boiler furnace 1985 / HK EE, HE ME NL
18 Collapse of
boiler furnace 1976 / HK EE ME L
9 Explosion 1988 / HK EE ME L
13 Explosion 1988 / HK EE ME L
14 Explosion 1985/ HK HE ME L
17 Explosion 1976 / HK EE ME L
1 Fire 1995 / HK HE EE L
3 Fire 1991 / HK EE ME L
12 Fire 1988 / HK EE ME L
16 Fire 1984 / HK EE ME L
21 Furnace 1993 / HK EE ME L
blowback
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Injuries Fatalities Extra Info proper maintenance,
Prevention engage
/ Reccommendation
competent person, register boiler
0 1 under boiler & pressure vessel
authority
engage boiler inspector to
1 0 examine piping system
severe damage to
0 0 boiler
severe furnace boiler inspector should test all
0 0 damage safety protection devices
regular examination and
4 1 maintenance
0 2
1 0
2 0 Proper maintenance
Proper operating procedure,
1 2 provide training to operator
Installation should be done by
1 1 expert
Appropriate material selection,
0 0 operate at correct operating
condition
operate at correct operating
0 0 condition
Provide training, hire competent
2 0 person
Provide training, hire competent
2 3 person, provide safe operating
procedure
1 1 Provide training
0 0 Proper maintenance
provide training, hire competent
0 3 person
0 1 Proper maintenance
6 0
0 0
2 0 Proper maintenance
2 0 Proper maintenance
55 26
Source
US Department of Labor
ARIA
The Commonwealth of
Massachusetts
ARIA
US Department of Labor
Contributory Factors
Human Error (HE) Equi pment Error (EE) Des ign Error (DE)
Sub-Contributory Factors
Carbon
monoxide Type of Incident
release 2 30
25
20
15
10
5
Type of Incident
30
25
Collapse of 20
boiler furnace 15
3 10
Explosion 27 5
Fire 7 0
se ce on re ge ck d re
a na i Fi a ba rge tu
Fuel Oil Spillage le ur os ill a p
ow
n
re f pl p ow c h R u
4 de er Ex il
S bl di
s bl
i il O ce am
ox o l
na ui
d
Furnace on o fb Fu
e
ur t fl ste
m F
blowback 1 on ps
e ho
a rb lla
hot fluid C Co
discharged 1
Rupture 2
steam blown
of 4
Severity of
Incident Severity of Incident
Injury Death
55 26
Death
67.90% 32.10%
Injury
0 10 20 30 40 50 60
Linearity
Linear Non-linear
40 10 Linearity Between Contributory and Sub-contributory Factor
80.00% 20.00%
Boiler Incident
ma n Error (HE)
ent
ent
ck d re of
ba a rge ptu n
ow sc
h R u ow
bl di bl
ce d am
ui ste
t fl
ho
40 50 60
-contributory Factor