Sie sind auf Seite 1von 4

VERTICAL VAPOR LIQUID SEPARATOR SIZING ###

CheGuide.com Tag No. V-101 No Specia


Chemical Engineer's Guide Description Receiver Glycol or A
User Date 5/21/2017 Compress
Input By CheGuide Expander
Without M
Inlet Nozz
INPUT ###
Vapor Flowrate 10000.0 Kg/h Operating Pressure 10.0 Barg ###
Vapor Density 20.180 Kg/m³ K Value Criterion No Special Requirement ###
Liquid Flowrate 5000.0 Kg/h K Value Calculated 0.105 m/s GPSA Engi
Liquid Density 736.10 Kg/m³ User Input K Value m/s ###
Liquid Holdup Time 5.0 min Diameter Calculated 1100 mm ###
Slug Capacity 0.57 m³ User Input Diameter mm ###
L/D Maximum 3.0 ###
###
INLET NOZZLE SIZING VAPOR OUTLET NOZZLE SIZING ###
Inlet Nozzle Half Open Pipe Momentum 4500 Kg/m.s² Value of K
Momentum 2100 Kg/m.s² Pipe ID Calculated 108.3 mm ###
User Input Kg/m.s² Select Pipe ID 6.0 inch ###
Pipe ID Calculated 145.6 mm Sch/ Thick 40.0 ###
Select Pipe ID 6.0 inch Pipe ID Selected 154.1 mm ###
Sch/ Thick 40.0 ###
Pipe ID Selected 154.1 mm ###
LIQUID OUTLET NOZZLE SIZING ###
Velocity 1.0 m/s ###
Pipe ID Calculated 49.0 mm ###
Select Pipe ID 2.0 inch ###
Sch/ Thick 40.0 ###
Pipe ID Selected 52.5 mm ###
###
###
SEPARATOR SIZING SUMMARY Summary
Half Pipe
With Without
Type With Mist Eliminator Mist Eliminator ###
Mist Eliminator
D Separator Diameter 1100 mm ###
L Separator Length 2900 mm h7 ###
h6 ###
h1 Low liquid level to Bottom T/L 150 mm ###
D
h2 Level Range 1202 mm h5 h5 ###
h3 High liquid level to Inlet nozzle 330 mm ###
h4 Diameter of Inlet nozzle 168 mm h4 h4 ###
h5 Inlet nozzle to Mist Eliminator 600 mm h3 h3 ###
h6 Thickness of Mist Eliminator 150 mm ###
h2 h2
h7 Mist Eliminator to Top T/L 300 mm ###
h1 h1
###
L/D 2.64 ###
Mesh Partial Mesh Blanket 700 mm Diameter
L/D Calcul
VERTICAL VAPOR LIQUID SEPARATOR SIZING ###
CheGuide.com Tag No. V-101 No Specia
Chemical Engineer's Guide Description Receiver Glycol or A
User Date 5/21/2017 Compress
Input By CheGuide Expander
Without M
Inlet Nozz
INPUT ###
Vapor Flowrate 22046.2 lb/h Operating Pressure 145.0 PSIG ###
Vapor Density 1.260 lb/ft³ K Value Criterion No Special Requirement ###
Liquid Flowrate 11023.1 lb/h K Value Calculated 0.345 ft/s GPSA Engi
Liquid Density 45.95 lb/ft³ User Input K Value ft/s ###
Liquid Holdup Time 5.0 min Diameter Calculated 3.5 ft ###
Slug Capacity 149.52 Gallon (US) User Input Diameter ft ###
L/D Maximum 3.0 ###
###
INLET NOZZLE SIZING VAPOR OUTLET NOZZLE SIZING ###
Inlet Nozzle Half Open Pipe Momentum 3000 lb/ft.s² Value of K
Momentum 1400 lb/ft.s² Pipe ID Calculated 4.27 inch ###
User Input lb/ft.s² Select Pipe ID 6.0 inch ###
Pipe ID Calculated 5.74 inch Sch/ Thick 40.0 ###
Select Pipe ID 6.0 inch Pipe ID Selected 6.065 inch ###
Sch/ Thick 40.0 ###
Pipe ID Selected 6.065 inch ###
LIQUID OUTLET NOZZLE SIZING ###
Velocity 3.3 ft/s ###
Pipe ID Calculated 1.9 inch ###
Select Pipe ID 2.0 inch ###
Sch/ Thick 40.0 ###
Pipe ID Selected 2.067 inch ###
###
###
SEPARATOR SIZING SUMMARY Summary
Half Pipe
With Without
Type With Mist Eliminator Mist Eliminator ###
Mist Eliminator
D Separator Diameter 3.5 ft ###
L Separator Length 10.0 ft h7 ###
h6 ###
h1 Low liquid level to Bottom T/L 6.0 inch ###
D
h2 Level Range 53.4 inch h5 h5 ###
h3 High liquid level to Inlet nozzle 12.0 inch ###
h4 Diameter of Inlet nozzle 6.6 inch h4 h4 ###
h5 Inlet nozzle to Mist Eliminator 24.0 inch h3 h3 ###
h6 Thickness of Mist Eliminator 6.0 inch ###
h2 h2
h7 Mist Eliminator to Top T/L 12.0 inch ###
h1 h1
###
L/D 2.86 ###
Mesh Partial Mesh Blanket 2.5 ft Diameter
L/D Calcul