Sie sind auf Seite 1von 2

BIS for LED Luminaries

10322 (part 5/ sect 1 ) testing required

Clause applicable - 4,5,6,7,10,11,14,15,16

Not applicable clause –8,9,12,13,17

4.1.1 Applicable ( yes)- information for luminaries design considered ( only)

5.2.2 type of protection-class III, 5.2.3- degree of protection- IP-21

5.2.4 Luminaries suitable for mounting on non combustible material,

5.2.5 Luminaries suitable for normal use.

Marking Cl 6(3) ( 6.3.2, 6.3.3, 6.3.3.9 (supply current 0.500mA ), 6.3.3.14, 6.3.3.17, 6.3.4)

Construction Cl 7(4) – 7.4.2, 7.4.3, 7.4.8 switch adequate rating and fixing , polarized supply ,

( 7.4.9 & 7.4.10 are not applicable)

7.4.11.1, 7.4.11.4,7.4.11.5, 7.4.12.1 ( screw not made of soft metal & screw dia), 7.4.12.2

7.4.13- mechanical strength , 7.4.13.1 – impact test- live parts, protection, cover

7.4.13.3 straight test finger

7.4.15- no fiercely burning material

Luminaries made of thermoplastic material with lamp control gear

7.4.16.1 – lamp control gear spacing (10mm)

7.4.25- no sharp point or edges,

Creepage distances and clearance Cl 8(11)

Provision for Earthing 9(7)- no test of it applicable

Terminals – screw terminal – Cl 10(14)

- Screw terminal and electrical connection – Cl. 10(15)

External and internal wiring – Cl 11(5)- 11.5.2.1, 11.5.2.2, 11.5.2.3 ( type)

11.5.3.4. – joint & junction effectively insulated, strain on internal wiring

11.5.3.7- wire end are not tinned


Protection against electric shock – Cl 12(8)

Endurance test and thermal test –Cl 13(12)

Resistance to dust and moisture – Cl 14(9) 14.9.1&2 – Ip21 ( no contact with live part)

14.9.3- humidity test ( 48 hrs) ( at 28 degree and 93%RH)

Insulation resistance and electric strength – Cl 15(10)

15.10.2.1- between current carrying part and metal part.

15.10.2.2- electrical strength test at 500V test, between current carrying parts of different polarity,

SELV luminaire

Resistance to heat , fire and tracking- Cl 16(13)- plastic enclosure at 75 degree, needle flame test (10s)
for PCB, glow wire test ( 650 degree)plastic enclosure , tracking test for pcb

Photometric test – (Cl -17)-as LED luminaries not covered under IS 13383 (part-1)

Test passed – CL- 4,5,6,7,10,11,14,15,16.

No of test applicable/ total

Marking 6.3 – 5/28

Construction 7.4- 8/127

Creepage & earthing cl 8 & 9)- 0/9 & 0/19

Terminals 10.14, 10.15 -2

External & Internal wiring 11.5 - 5/11

Cl 12 & 13 – 0/18 & 0/8

Cl 14- 4/12

Cl 15- 4/7

Cl 16- 4/4

Cl 17- 0/2