Load Plot:
The load is applied at the corner post with 4 springs given at the bottom.
Deflection Plot:
Has it can be seen from the below deflection plot, applying a load at the corner post has a twisting
effect on the container which is tied to a hook only (Pinned support) without and other support. Due
to this twisting effect the relative deflection comes out to be very high
Node 7
Node 1
Deflection:
From the above displacement values, it can be seen that the relative deflection in Z-
direction is very high; 498-345 = 153mm
The allowable displacement for the corner post = L/250 ~ 1798 / 250 = 7.192 mm <
153mm.
From STAAD, the beam deflection summary is printed below.
Case 2: Horizontal Impact on Corner Post with pinned supports
Load Plot:
The load is applied at the corner post with pinned supports given at the ends of the beam on which
the force acts:
Deflection Plot:
Has it can be seen from the below deflection plot, the deflection is negligible.
Node 7
Beam 166
Beam 1
Node 1
Deflection:
Load Plot:
The load is applied at the corner post with pinned supports given at the ends of the beam on which
the force acts:
Deflection Plot:
Has it can be seen from the below deflection plot, applying a load at the corner post has a twisting
effect on the container which is tied to a hook only (Pinned support) without and other support. Due
to this twisting effect the relative deflection comes out to be very high
Node 7
Beam 166
Beam 1
Node 1
Deflection:
From the above displacement values, it can be seen that the relative deflection in Z and
X-direction is very high; XDir = 1050-889 = 161mm and ZDir = 243-228=15mm
The allowable displacement for the corner post = L/250 ~ 1798 / 250 = 7.192 mm <
161mm and 15mm.
From STAAD, the beam deflection summary is printed below.
Case 4: Horizontal Impact on Corner Post in X-Direction with pinned supports
Load Plot:
The load is applied at the corner post with pinned supports given at the ends of the beam on which
the force acts:
Deflection Plot:
Has it can be seen from the below deflection plot, the deflection is negligible.
Node 7
Beam 166
Node 1
Beam 1
Node 1
Deflection: