Sie sind auf Seite 1von 2

Experiment 1: determination of the operation and characteristic of flow meter and rotameter

Pressure, PT1 Mass flow Rotameter Temperature, Mass flow Rotameter


(bar) meter, FT1 (LPM) TT1 (℃) meter reading reading at
(LPM) FT1 at standard
standard condition
condition
0.76 12.4 10 29.3
0.73 23.5 20 29.3
0.71 34.1 30 29.3
0.68 43.9 40 29.4
0.62 52.5 50 29.4

Experiment 2: determination of the operation and characteristic of venture meter

Pressure, PT1 Rotameter Temperature, Differential pressure, Calculated flowrate,


(bar) (LPM) TT1 (℃) DPT1 (bar) Q (LPM)
0.77 10 29.4 3
0.73 20 29.4 3
0.70 30 29.4 4
0.67 40 29.4 6
0.62 50 29.5 7

Experiment 3: determination of the operation and characteristic of orifice meter

Pressure, PT1 Rotameter Temperature, Differential pressure, Calculated flowrate,


(bar) (LPM) TT1 (℃) DPT1 (bar) Q (LPM)
0.76 10 29.4 3
0.73 20 29.5 4
0.70 30 29.5 5
0.68 40 29.5 9
0.67 50 29.6 11
Experiment 1: determination of the operation and characteristic of flow meter and rotameter

Pressure, PT1 Mass flow Rotameter Temperature, Mass flow Rotameter


(bar) meter, FT1 (LPM) TT1 (℃) meter reading reading at
(LPM) FT1 at standard
standard condition
condition
1.74 15.4 10 29.7
1.71 29.9 20 29.6
1.67 43.4 30 29.6
1.63 55.9 40 29.6
1.50 62.3 50 29.6

Experiment 2: determination of the operation and characteristic of venture meter

Pressure, PT1 Rotameter Temperature, Differential pressure, Calculated flowrate,


(bar) (LPM) TT1 (℃) DPT1 (bar) Q (LPM)
1.76 10 29.5 2
1.70 20 29.5 3
1.67 30 29.6 4
1.64 40 29.6 5
1.55 50 29.6 7

Experiment 3: determination of the operation and characteristic of orifice meter

Pressure, PT1 Rotameter Temperature, Differential pressure, Calculated flowrate,


(bar) (LPM) TT1 (℃) DPT1 (bar) Q (LPM)
1.73 10 29.6 2
1.70 20 29.6 4
1.67 30 29.6 6
1.63 40 29.7 9
1.59 50 29.7 11