ETABS 2015 15.1.

0 License #*1H6QHQCU7BGD3KX

ETABS 2015 Concrete Frame Design


Eurocode 2-2004 Column Section Design

Column Element Details Type: DC High

Level Element Section ID Combo ID Station Loc Length (mm) SOM LLRF
Story2 C12 C1300x1300 EQ1 0 3600 0.473

Section Properties

b (mm) h (mm) dc (mm) Cover (Torsion) (mm)


1300 1300 60 30

Material Properties

E c (MPa) f ck (MPa) Lt.Wt Factor (Unitless) E s (MPa) f yk (MPa) f ywk (MPa)


35220.46 40 1 200000 413.69 413.69

Design Code Parameters

ɣC ɣS α CC α CT α LCC α LCT
1.5 1.15 1 1 0.85 0.85

Axial Force and Biaxial Moment Design For N Ed , M Ed2 , M Ed3

Design N Ed Design M Ed2 Design M Ed3 Minimum M2 Minimum M3 Rebar Area Rebar %
kN kN-m kN-m kN-m kN-m mm² %
1207.1719 -109.7236 -374.1956 52.3108 52.3108 16900 1

Axial Force and Biaxial Moment Factors

M 0Ed Moment M add Moment Minimum Ecc β Factor Length


kN-m kN-m mm Unitless mm
Major Bend(M3) -189.5205 0 43.3 1 2800
Minor Bend(M2) -54.3211 0 43.3 1 2800

Axial Compression Ratio

Conc Capacity (α CC *A*f cd ) Compressive Ratio Comp Ratio Seismic Ratio


kN N Ed /(α cc *A*f cd ) Limit Load? OKay?
45066.6667 0.027 0.55 Yes Yes

Four-storey frame.EDB Page 1 of 2 07/08/2017


ETABS 2015 15.1.0 License #*1H6QHQCU7BGD3KX

Shear Design for V Ed2 , V Ed3

Shear V Ed Shear V Rdc Shear V Rds tan(θ) Rebar A sw /s


kN kN kN Unitless mm²/m
Major, V Ed2 3948.3332 920.356 3948.3332 0.4 3934.02
Minor, V Ed3 3948.3332 920.356 3948.3332 0.4 3934.02

Rules: Joint shear stress ratio is only determined for a station

a) if the station has a beam-column joint (top of the column),

b) if the frame is a DCHe or DCM moment resisting frame,

c) if the column above is a concrete column when it exists,

d) if all the beams framing into the column are concrete beams

e) if the connecting member design results are available, and

f) if the load combo involves seismic load.