P.D.. 1096 National Building CodeMaximum height of a combustible stand. 2.70 mts.

Minimum
spacing for seats in a chair type measurement from back to back. 0.85 mtr.Maximum line of travel to
an exit of an aisle. 45.00 mts.Maximum slope of an aisle. One is to Eight (1:8)In standard seating,
the minimum spacing of rows measured from back to back. 0.84 mtr.Minimum width of any seat.
0.45 mtr.Minimum area of a double acting door view panel. 1,300 sqmm / 1.30 sqm.Minimum clear
width of an exit doorway. 0.70 mtr.Maximum width of an exit door leaf. 1.20 mts.Minimum width of an
exit corridor. 1.10 mts.Minimum number of exit for floors above the first storey having an occupant
load of 2more than 10 Number of exit for occupant load of 599-999. 3Minimum downward projection
of a draft curtain 0.30 mtr.Maximum floor area for an attic made of combustible materials. 250.00
sqmMaximum center to center spacing of a draft curtain sprinkler. 1.80 mts.Maximum floor area for
an attic made of incombustible materials. 750.00 sqm.Standard gauge for metal hoods in barbeques.
Ga. 18Minimum height of a Siamese connection above grade. 300 mmStandard maximum distance
of a standpipe from an opening in a stairway. 300 mmMinimum wall thickness of a fireplace. 200
mmMinimum number of exit for a projection room. 2Minimum extended portion of a chimney above
the roof. 600 mmMinimum air space between walls of a masonry chimney above the roof. 2" / 50
mmMinimum thickness of glass used for floors. 12.5 mmMaximum rise of one row of seat to the
next. 400 mm / 0.40 mtr.Minimum number of exit for stands within a building serving an occupant
load of 300. 3Minimum height of a guard rail located in front of the grandstand. 0.90 mtrMinimum
width of a run in a stand stair. 0.28 mtr.Minimum spacing for seats with backrests measured from
back to back. 0.75 mtr.Minimum spacing for seats without backrests measured from back to back.
0.60 mtr.Minimum width of an exit door in an aisle. 1.70 mts.Minimum intensity of lights for exits.
10.70 luxMinimum width of side aisles. 1.10 mts.Minimum increase in width of aisles for every linear
meter. 30 mmMinimum width of an aisle serving only one side. 800 mm / 0.80 mtr.Open space
requirement for an interior lot. 50% of lot areaOpen space requirement for a corner lot or a through
lot. 10% of lot areaBounded on all sides or around its periphery by building lines. Inner
courtMinimum stair width for a residence. 750 mm / 0.75 mtr.Standard minimum area of a toilet. 1.20
sqm.Minimum dimension of a kitchen. 1.50 mts.Minimum area for vent shafts. 1.00 sqm.Air space
requirement for a school room per person. 3.00 cum.Air space requirement for a habitable room per
person. 14.00 cum.Minimum area of opening of an air duct. 300 sqmm / 0.30 sqmMaximum
projection beyond the property line of a footing along the national road and at 300 mmleast 2.40 mts.
In depth. Minimum clearance of a canopy or a marquee from the sidewalk. 3.00 mts.Minimum stair
width for occupant load of less than 50. 0.90 mtr.Minimum width of a temporary walkway. 1.20
mts.Minimum clearance of an arcade above sidewalk. 3.00 mts.Vacant space left between the
building and lot lines less than 2.00 mts in width. SetbackMinimum horizontal dimension of a court.
2.00 mts.Minimum width of a passageway connecting a street and a court. 1.20 mts.Standard air
space requirement per person for factories. 12.00 cum.Minimum headroom clearance for a
mezzanine. 1.80 mts.Air supply per person per minute for auditoriums. 0.30 cumMinimum total area
of a window or an opening for a room without artificial ventilation. 10% of flr. AreaMinimum
dimension for a vent shaft. 0.60 mtr.Minimum horizontal clearance of the curb line to the outermost
edge of the marquee. 300 mmMinimum clearance of the lowest portion of an awning to the ground.
2.40 mts.Minimum height of a construction fence. 2.40 mts.Minimum live load bearing capacity of a
construction canopy. 600 kgs./sqm.Minimum height of a protective railing in a construction. 1.00
mtr.Minimum wind load capacity for roofs for vertical projection. 120 kgs./sqm.Maximum height of a
handrail above the stair thread. 0.90 mtr.Minimum ceiling height for naturally ventilated rooms. 2.70
mts.Minimum height of a handrail above the stair thread. 0.80 mtr.Maximum dimension of a stair
landing. 1.20 mts.Maximum slope of an exit court. One is to ten (1:10)Minimum width of run for
circular stair. 250 mmMinimum headroom clearance for any stair. 2.00 mts.Maximum slope for an
exit passageway. One is to Eight (1:8)Maximum height of a Siamese connection above the ground.
1.20 mMaximum distance of any portion of a building from the nozzle of a 23 mts fire hose. 6.00
mts.Minimum number of exit for any stage. 2Minimum extension of a proscenium wall above the
roof. 1.20 mts.Minimum width of a stair in a stage egress. 750 mmMinimum thickness of glass for
jalousies. 5.60 mmMaximum length of glass for jalousies. 1.20 mts.Minimum width of exit in a stage.
900 mmMinimum lateral spacing for plastic skylights. 2.50 mts.A store window in which goods are
displayed. Show windowMaximum width of a business sign. 1.20 mts.Minimum distance of a sign
from any electrical post or telephone wires. 1.00 mtr.Minimum open space requirement for a corner
lot. 10% of lot areaMinimum size of thread for an entrance or exit step. 300 mmMaximum slope for
an entrance or exit ramp. One is to ten (1:10)Minimum number of steps for an entrance or exit stair.
2Standard turn circle of a wheelchair. 1.50 mts.Office building parking ratio. 1:125 sqm. Of gross
floor areaStandard size of a perpendicular parking slot. 2.40 X 5.00 mts.Hotel building parking ratio.
1:10 bedroomsHospital building parking ratio. 1:25 bedsMaximum distance of a handicapped
parking from the facility being served. 60.00 mts.Colleges and university parking ratio. 1:5
classroomsTheaters, cinemas, auditoria, and stadia parking ratio. 1:50 sqm. Of spectators'
areaMinimum number of wheelchair seating space for 51-300 seating capacity for auditoriums.
4Minimum width of a dropped curb. 0.90 mtr.Minimum Dimensions of an accessible elevator. 1.10 X
1.40 mts.Maximum distance of an accessible elevator from the entrance of a building. 30.00
mts.Minimum height of signs on walls and doors for the disabled to see comfortable. 1.40
mts.Minimum door width for an accessible elevator. 0.80 mtr.Minimum dimensions for an accessible
water closet stall. 1.70 X 1.80 mts.Maximum height of signs on walls and doors for the disabled to
see comfortably. 1.60 mts.Minimum width of a parking slot for the disabled. 3.70 mts.Minimum run of
a stair for Group A dwellings (residential) 200 mmMinimum ceiling height from 3rd floor to
succeeding floors with artificial ventilation. 2.10 mts.Minimum area of rooms for human habitation.
6.00 sqm.Least dimension of rooms for human habitation. 2.00 mts.Least dimension of an air duct.
300 mmMaximum encroachment into a public sidewalk of a foundation at least 600 mm below 500
mmthe grade line. Minimum width of an exit door. 0.90 mts.Maximum width reduced by handrails
and doors fully opened to balconies and 200 mmcorridors Minimum width of stairs serving more than
50 occupants. 1.10 mts.Minimum width of stairs serving less than 10 occupants. 750 mmMaximum
reduction in width of a stair due to trims and handrails. 100 mmMinimum run of a winding stair. 150
mmMaximum run of a winding stair. 300 mmAllowable tolerance in the rise and run of every step. 5
mmWidth of stair requiring an intermediate handrail. 3.00 mts.Minimum width of an aisle serving
both sides. 1.00 mts.Maximum number of seats between the wall and the aisle. 7Maximum distance
between the back of each seat to the front of the seat behind it. 300 mmMaximum width of seat in a
stand. 480 mmMaximum projection of a penthouse or other projections above the roof. 8.40
mtsMaximum ratio of a penthouse area to that of the supporting roof. one third (1/3)Minimum
thickness of masonry chimney for residentials. 100 mmMinimum thickness of rubble stone masonry
chimney for residentials. 300 mmMinimum firebox wall thickness. 250 mmMinimum thickness of
smoke chamber back walls. 150 mmminimum thickness of front and side smoke chamber walls. 200
mmMinimum number of storeys requiring one (1) or more dry standpipes. 4Minimum volume of
water a dry standpipe should provide. 900 liters/minuteDiameter of a dry standpipe requiring a two-
way Siamese connection. 4" (100mm)Diameter of a dry standpipe requiring a three-way Siamese
connection. 5" (125mm)Diameter of a dry standpipe requiring a four-way Siamese connection. 6"
(150mm)Minimum volume of water an interior wet standpipe should provide. 190
liters/minuteMinimum diameter of a wet standpipe. 2" (50mm)Standard diameter of a dry standpipe
opening. 2 1/2" (63mm)Standard length of a fire hose. 23.00 mtsMaximum distance of a hose nozzle
to any portion of a building. 6.00 mts.Standard diameter of a wet standpipe valve. 38 mm
(11/2")Maximum projection into a sidewalk of a sign 4.50 mts. above grade. 1.00 mtr.Minimum
vertical clearance from the bottom of a signage to an arcaded sidewalk. 5.00 mts.Minimum vertical
clearance from the bottom of a signage to non-arcaded sidewalk. 3.00 mts.Number of days of work
abandonment of stoppage for a building permit to expire. 120 daysWidth of planting strip for
sidewalks 2.00 mts in width. 0.80 mtr.Minimum horizontal distance of the curb line to the outermost
face of an arcade. 500 mmMaximum vertical clearance of an arcade above grade. 6.00 mts.Slope of
ramp of road-way to sidewalk. 1/3 - 1/4Slope of driveway to sidewalk where the height of curb is 200
mm and above. One is to Eight (1:8)Minimum vertical clearance of primary lines from the crown of
the pavement when 10.00 mts.crossing the highway. Minimum vertical clearance of primary lines
from top of sidewalk when installed along 7.5 mts.the side of the highway. Vertical clearance of
secondary lines from sidewalks along or crossing the street. 7.5 mts.Minimum clearance of
conductors from the highest point of a roof. 2.50 mts.Maximum height of a dumbwaiter. 1.20
mts.Maximum area of a dumbwaiter. 3,861 sqcms.Minimum clearance of conductors from any
platform or ground or projection from which 3.00 mts.they might be reached. Minimum vertical
clearance of service drop of communication lines above ground at its 3.00 mts.point of attachment to
than building or pedestal. Vertical clearance of a service drop communication line when crossing a
street. 5.50 mts.Maximum capacity of a dumbwaiter. 277 kgs.Minimum width of an access road to a
cul-de-sac. 3.00 mts.Unit area per occupant for dwellings. 28.00 sqm.Unit area per occupant for
Hotels. 18.6 sqm.Unit area per occupant for offices and garages. 9.30 sqm.Unit area per occupant
for class rooms. 1.80 sqm.Unit area per occupant for stores - retail sales rooms upper floors. 5.60
sqm.Unit area per occupant for nurseries for children. 3.25 sqm.Unit area for stores -retail sales
room for basement and ground floor. 2.80 sqm.Unit area for hospitals and sanitaria. 8.40 sqm.Unit
area per occupant for aircraft hangars without repairs. 46.50 sqm.Unit area per occupant for
warehouses and mechanical equipment room. 28.00 sqm.Unit area per occupant for theaters and
the like. 0.65 sqm.Parking requirement for Hotels. 1 slot/5 roomsParking requirement for public
assembly buildings such as cinemas, auditoria, theaters, 1 slot/50 sqm. Of spectators' areaand the
like. Parking requirement for multi family living unit of 50 sqm floor area. 1slot/8 unitsParking
requirement for multi family living unit above 100 sqm floor area. 1 slot/unitParking requirement for
multi family living unit for 50-100 sqm floor area. 1 slot/4 unitsParking requirement for clubhouses,
beach houses, and the like. 1 slot/100 sqm of gross flr.areaParking requirement for motels. 1
slot/unitMinimum parking requirement for the handicapped. 1 slot/50 parking slotsParking
requirement for colleges and universities. 1 slot/5 classroomsParking requirement for elementary,
secondary, and vocational schools. 1 slot/10 classroomsIn BP344, the required width of a corridor.
1.20 mts.Maximum slope of a drop curb towards the street. 1:20Maximum slope of a drop curb
towards adjoining curb. 1:12Maximum spacing for wheelchair turnabouts. 12.00 mts.Maximum slope
of a ramp. 1:12Maximum distance of handicapped parking from the structure served. 60.00
mts.Preferred width of corridor for the disabled. 1.50 mts.Maximum height of a water closet from the
floor. 0.50 mts.Preferred height of switches from the floor. 1.10 mts.Minimum height of a switch from
the floor. 0.90 mts.Maximum height of a switch from the floor. 1.20 mts.Least dimension for a
parking slot for the disabled. 3.70 mts.In BP344, the minimum height of a handrail. 0.70
mtr.Maximum length of a ramp for wheelchair. 6.00 mts.Minimum length of a ramp landing for
wheelchairs. 1.50 mts.One or more habitable rooms which are occupied or which are intended or
designated to Dwelling unitbe occupied by one family with facilities for cooking , sleeping, living, and
eating. That portion of the foundation of a structure which spreads and transmits loads directly
Footingto the ground or soil. A continuous horizontal layer of masonry units. CourseA room or suite
of two or more rooms, designed and intended for , or occupied by one Apartmentfamily for living,
sleeping, eating, and cooking purposes. A stationary open hearth or brazier, either fuel-fired or
electric, used for food preparation. BarbecueA portion of the seating space of an assembly room, the
lowest part of which is raised Balcony1.20 mts or more above the level of the main floor. The pipe
which connects a flue-burning appliance to a chimney. Chimney connectorA hearth and fire chamber
or similarly prepared place in which a fire may be made and Fireplacewhich is built in conjunction
with a chimney. A horizontal structural piece which supports the end of the floor beams or joists or
walls Girderover opening. Same as heliport except that no refueling, maintenance, repairs, or
storage of Helistophelicopters is permitted. The vertical supports, such as posts or stanchions, as
used in indigenous or traditional Suportalestype of construction. Any surface or underground
construction covered on top, or any fire-proof construction Vaultintended for the storage of
valuables. A term which may be used synonymously with a partition. Cross wallThe unit area per
occupant for hotels. 18.60 sqm.The unit area per occupant for dining establishments. 1.40 sqm.The
unit area per occupant for theaters. 0.65 sqm.A building permit shall expire if work authorized is
abandoned or suspended at any time 120 days / 4 mos.after commencement for a period of. Front
yards for commercial buildings abutting a road-right-of-way of 25-29 meters shall 8.00 mts.have a
minimum width of Offices shall be provided how many cubic meters of air per person? 12.00
cum.Multiple living units of up to 6 units built on the same lot shall have an access road 3.00
mts.directly connecting said building to a public street a width of. Sidewalks of 2 mts or more in width
shall include on its outer side a planting strip of not 800 mm / 0.80 mtr.less than how many
millimeters in width? Arcades shall be cantilevered from the building line over the sidewalk and the
horizontal 500 mmclearance between the curb line and the outermost face of any part of the arcade
shall not be less than. Printing plants shall be classified under what type of occupancy. Business and
mercantilePower plants shall be classified under what type of occupancy. IndustrialConvents shall
be classified under what type of occupancy. Residentials, hotels and apartments.Repair garages
shall be classified under what type of occupancy. Storage and hazardousReformatories shall be
classified under what type of occupancy. InstitutionalTurnabout should also be provided at or whithin
how many meters of dead end. 3.50 mts.In B.P. 344, the maximum slope a ramp is. 1:12Under B.P.
344, a level area of not less than how many meters shall be provided at the 1.80 mts.top and bottom
of any ramp. Under what classification of occupancy does Mental Hospitals fall? InstitutionalUnder
what classification of occupancy does Monasteries fall? Residentials, hotels and apartments.Under
what classification of occupancy does Aircraft hagars fall? Business and mercantileUnder what
classification of occupancy does cold storage and creameris fall? IndustrialUnder what classification
of occupancy does private garage fall? AccessoryMinimum loading slot requirement for Hospitals
and hotels. 1 truck loading slotMinimum travel distance from handicapped parking to facility being
served. 60 mts.Percentage required for number of parking if parking garages are available within
200 20%meters of structure. Parking requirement for amusement centers. 1/50 sqm of gross floor
areaParking requirement for markets. 1/150 sqm of shopping flr areaParking requirement for
neigborhood shopping centers. 1/100 sqm of shopping flr areaParking requirement for multi-family
living units of more than 100 sqm of living unit area. 1/living unitParking requirement for multi-family
living units of up to 50 sqm of living unit area. 1/8 living unitsParking requirement for places of
worhip. 1/50 sqm of congregation areMaximum projection of a balcony over a street of over 3 meters
but not more than 6 mts. 0.60 mtr.Maximum projection of a balcony over a street of 10 mts to less
than 11 mts in width. 1.00 mtr.Maximum height of 1st the floor for a 2-story wood structure with a
height of 7 mts. 4.50 mts.Maximum spacing of posts for 2-story wooden structure with a height of 8
mts. 4.50 mts.Under what classification of occupancy does fences of over 1.80 mts in height fall?
AccessoryUnder what classification of occupancy does Aircraft repair hangars fall? Storage and
hazardousUnder what classification of occupancy does factories and workshops using
Industrialincombustible and non-explosive materials. Under what classification of occupancy does
wood working establishements fall? Storage and hazardousUnder what classification of occupancy
does police and fire stations fall? Business and mercantileStandard length of a Wheelchair. 1.10 -
1.30 mts.Standard width of a wheelchair. 0.60 - 0.75 mts.How many meters above the floor is the
comfortable reach of persons confined to a 0.70 - 1.20 mts.wheelchair. How many meterd is the
comfortable clearance for knee and leg space under tables for 0.74 mts.wheelchair
users. Accessibility, reachability, usability, orientation, workability and efficiency, and ___ are
Safetythe basic planning requirements of BP344. Number of wheelchair seating for an assembly
seating capacity of 51-300. 4R.A. 7277 Magna Carta for DisabledPersonsA long interior
passageway providing access to several rooms. CorridorA raised rim of concrete, stone or metal
which forms the edge of street, sidewalk, etc. Curb