KELOMPOK 4:
KELAS 1 D
9000
INSTRUCTION MANUAL
DAFTAR ISI
1. Perkenalan
2. Safety Issues (please keep follow all the instructions) 2
3.Safety Precautions
3-1 Power and Earth Cables
3-2 Environment
3-3 Films and Chemical Solutions
4. Parts Name
5. Optional Parts
6. Outer Measurement (mm)
7. Installation
7-1 Preparation for Installation
7-2 Installation
7-3 Handling the Waste Chemical Solution and Drain Hose
7-4 Connecting the Water Hose
7-5 Power Supply
8. Preparation for Operation
8-1 Cleaning the Developing and Fixing Racks
8-2 Mixing the Developing Solution
8-3 Mixing the Fixing Solution
8-4 Pouring the Chemical Solution
8-5 Setting the Racks
9. Operating Instructions
9-1 Power Switch and Water Supply
9-2 Developing the Films
9-3 Turning off the Power
10. Operating Explanation
11. Maintenance and Cleaning
11-1 Daily Inspection
11-2 Monthly Maintenance
11-3 Changing the Chemical Solution
11-4 Periodical Inspection
11-5 List of Consumables
11-6 Inspection Check Sheet
12. Damage and Inspection
13. Basic Spec
14. Option Parts
14-1 Stand
14-2 Water Solenoid Valve
14-3 Water Filter Kit
14-4 Water Pump Unit
15. Warranty and After Service
1
1. Introduction
Thank you very much for your purchase of desktop compact automatic film processor,
ECOMAT9000.
This manual includes the basic instructions of daily use, maintenance, and countermeasures
during the troubles of ECOMAT9000.
It is important that all the instruction, description and safety issues are reviewed thoroughly
before using the equipment. After you finish studying the manual, please keep this manual with
the warranty card.
Please read the "safety issues" thoroughly before using the equipment.
The following "safety issue" includes information on proper use to avoid damage to the
equipment and human (users). There are many different diagrams and signs showing different
meanings and all of them have important meanings. Please follow them carefully.
Warning Please do not ignore this sign. It may cause serious injuries or
Warning death to the user.
Warning Please do ignore this sign. It may cause injuries and damage to
Warning the equipment.
Warning
Do not open the top cover while the equipment is running. The equipment includes
motors which may cause injuries if you touch it. The chemical solution may get into
your eyes or clothe.
Please turn off the power during maintenance. It may cause electric shock.
Make sure the earth cable is inserted. It may cause electric shock if it is not inserted
properly.
Use only 200V. It may cause fire and electric shock.
For any trouble or damage, stop the operation, pull out the power cable and contact
your local sales agent or distributor. If operation continues during any trouble, it may
cause fire or electric shock.
2
Warning
Do not splash any liquid to the equipment. Do not install the equipment where water
is present. It may cause damage and electric shock.
During operation, please make sure the equipment is stable and do not shake the
unit. It may cause damage, electric shock or fire.
Only a authorized engineer should open and fix the unit. It may cause fire, electric
shock or injuries unless you are trained. Please contact your local agent or
distributor.
Please do not modify the unit. It may cause fire, electric shock and injuries.
Warning
Please use only a 200V, 10A cable. Avoid multiple plug connection. It may cause
fire, trouble or injuries.
For installation, find a flat location where there is no vibration. If it is not properly
installed, the different chemical solution may get mixed up and cause trouble.
Make sure to thoroughly wash off the chemical solution in case you come in contact.
After handling the chemical solution, please wash hands. If the chemical solution
gets inside the eyes, wash thoroughly with water and consult with a doctor.
Make sure there is enough ventilation. If there is not enough ventilation, it may
cause trouble.
Do not place any objects on top of the power cable. It may cause fire.
Do not place any objects on top of the unit. It may cause damage, fire or injuries.
Place the power cable so that it may not be accidently pulled out. It may cause
injuries or damage.
When the power cable is pulled, do not pull the cord. Hold the power plug to pull it
out. It may cause trouble or electric shock.
During transportation, turn off the power, pull out the power cable and take out all
the chemical solution. Make sure the unit does not turn over. It may cause damage
and injuries.
Do not use mobile phone or any other device which generates electromagnetic field.
It may cause damage to the unit.
The unit is not explosion and fire proof. Do not use the unit where there are
flammable products.
In case the equipment is not used for a long time, turn off the power and pull out the
power cable. It may cause damage or fire.
If the unit is used after the power has been turned off for a long time, make sure the
unit is operating properly. It may cause damage or fire.
Do not turn the unit side ways during transportation. It will cause damage.
This equipment weights about 30kg. Make sure to be careful when opening the
package and handling the unit. It may cause injury and damage to the unit.
3
4. Parts Name
4
%RH
3. Safety Precautions 30 80
3-2 Envirnment
Requested conditions: 10 30 5
Temp:10 30
Humidity:30 80 RH
Water Temp: 5 Above
The dark room will require a ventilation fan and exhaust pipe. Dark Room lamp should be diode
type S2 (ortho regular)
Warning
Do not place any unnecessary objects inside the dark room.
5
4-1 Name of Parts A
Insertion case
Insertion case lid
Top cover
Drying cover
Rubber stand
Power switch POWER
Ready lamp READY
Front cover
4
B
l
D
E
C
C
r
D
r
R
D
R
r
D
e
r
Measuring Cup
1
R
e
p
l
e
n
i
s
h
i
n
g
t
a
n
k
(
1
0
L
)
2
F
o
r
D
E
V
S
o
l
u
t
i
o
n s
o
a l
n u
d t
i
F o
I n
X
5. Optional Parts
Spare parts
No.
1 2
1 117-3730005 O-ring ,P12 4
2 117-3730006 O-ring,P18 2
3 4 5 3 117-3270045 Gear,rightA 2
4 117-3270046 Gear,leftA 2
5 117-3270047 Gear,leftB 1
6 117-3850002 Spring,roller 4
6 7 8 7 117-3850001 Spring,roller 4
8 117-3220011 Support,shaft 2
9 117-3610051 Fook,right 1
9 10
10 117-3610052 Fook,left 1
565
109 614
723
Plane view
723
463
1013
655
550
570
This equipment is designed to be installed in a complete dark room. Check the measurement of
the equipment and keep enough room and space in the dark room, and also keep enough
space to work for changing the films. Make sure there is a power outlet for 100V - 200V, 10A.
Make sure there is water supply, and drainage. In case you purchase an optional water
solenoid valve, water filter unit, water pump unit, make sure there is enough space, installation
space and additional power outlet.
(For more details on the optional parts, please refer to page 23).
7-2 Installation
Please conduct the installation inside the dark room only. Please adjust the height position of
the equipment by turning the rubber of the stand to make sure it is parallel to the ground.
Ventilation fan
Dark room
Exhaust exit
Warning
If the main unit is tilted, the developing solution and fixing solution may get mixed up inside the
unit and over flow. Please make sure the unit is installed flat to the ground.
Please refer to the following recommended environment for installation
TEMP 10 30
HUMIDITY 3 0 80 RH
WATER TEMP 5 or above
7. Installation
Make sure there is ventilation fan and exhaust exit inside the dark room.
Connect each of the waste and water hose. Insert the Waste Hose to the waste drain. Collect
the chemical solution waste by connecting the waste hose to the tank. Please cut the hose to
the necessary length. Ask the waste disposal agent to collect the chemical solution waste.
Warning
Make sure the hoses do not bend in a U shape. Please check the flow of the waste is smooth. If
there is any clog inside the hose, it may cause damage to the main unit.
Tap water
Water coupling
Hose joint
Loosen the hose joint and insert the water coupling to the tap water.
Use the 3 screws and hold the water coupling to the tap water
Check the length of the water hose and cut to the right length.
After completing the connection, cut to the hose to the necessary length and dispose the
remains.
After the hose is connected, run the water to check if there is no leak.
Warning
Do not tighten the hose joint to tightly. The bucking may break and cause water leakage.
Warning
The water coupling comes with a continuous flow valve. (less than 2 liter / min) In case a
different type of water hose is used, please use this water coupling.
Warning
Make sure to hold onto the plug part when pulling out the power plug. Do not pull the cord.
8. Preparation for Operation
10
Measuring Cup Solution A
Solution B
10 liter tank
Warning
When handling the chemical solution, make sure to use rubber gloves to avoid contact with the
solution. Clean your hands thoroughly afterwards.
Both Solution A and Solution B is highly concentrated solution, and may cause crystallization
when the room temperature is cold. In case the solution is crystallized, mix the solution with
warm water and pour into the 4 liter pot.
Warning
The chemical waste needs to be collected using a waste tank and dispose it accordingly to your
the country's regulation.
11
Measuring Cup
Solution A
Solution B
10 liter tank
Warning
When handling the chemical solution, make sure to use rubber gloves to avoid contact with the
solution. Clean your hands thoroughly afterwards.
If you mix the A solution with B solution, it will dissolve and become cloudy. Make sure to water
down the solution A and then mix the solution while adding the Solution B.
Warning
The chemical waste needs to be collected using a waste tank and dispose it accordingly to your
the country's regulation.
Valve
Insertion line
solution level
9. Operating Instructions
Warning
In case the fixing solution gets inside the developing rack, the final image will be effected.
Make sure to clean the developing rack to get clear image.
Both the developing and fixing solution contains a high percentage of alkali and acidic solution.
Make sure they do not get mixed up inside the unit.
1) Set each racks, developing rack, fixing rack, water rack carefully in each location.
2) Slide each of the racks towards the left side until there is a stopper. The gear will hold the rack.
3) Place the Drying rack on top of the Water Rack, and the air case to the dryer exit.
Drying rack
Drying rack Hook
Washer Rack
Air case
Drying rack
Stay
Place the cross over guide to the ratchet in between each of the racks.
Check the arrow mark and place it to the same direction of the film. Listen carefully to the sound
of the gear when it connects. Make sure the cross over guide does not move.
9-1 Power Switch and Water Supply
Warning
Make sure the power plug and the earth plug are connected to avoid any power leakage.
Check inside to make sure the solution is filled. The unit may break if the power is turned on
without any solution.
Warning
Make sure to use the appropriate film and dark room lamp during operation.
5) After inserting the films, the READY sign will start to flash and buzzer will go off. After closing
the lid, you may turn on the light inside the dark room.
6) The READY sign will disappear when the films are inserted.
7) When the READY sign starts to flash, the next film is ready to be inserted.
8) When inserting films continuously, please follow the above instructions, 3 to 7.
9) When the operation is completed, make sure to close the water supply.
Insert Case
Warning
If you keep the lid, film insertion case and top cover, closed it will cause damage to the top
cuver unit ,or poor image due to excessive moisture and gas.
11. Maintenance and Cleaning
Temperature Control
The heaters inside the developing rack and fixing tank will control the temperature of the
developing solution. Once it reaches the temperature, the ready sign will light and the buzzer
will go off three times. In order to maintain the temperature of the developing solution, the
heater will turn on to control the temperature. The temperature of the Dryer will also stop once it
reaches the set temperature. Once the temperature drops, the temperature control will start
again.
Peringatan
Jikaada larutan developer yang terciprat ke dalam kotak penyisipan,maka gambar akan
terpengaruh.
B) Jika kotak penyisipan dibawa keluar, tangani dengan hati-hati karena casing dan
tutupnya akan terlepas dalam 2 bagian.
C) Setelah dibersihkan, pastikan kotak penyisipan terhubung dengan benar.
2) Memeriksa pembuangan limbah
Pastikan untuk memeriksa sisa pembuangan limbah
Peringatan
Jika Anda menggunakan tangki pembuangan ketika penuh dengan pembuangan limbah, limbah
akan bocor ke lantai.
Peralatan ini menggunakan bahan kimia dan air. Untuk menjaga kualitas satuan dalam kondisi baik, silakan
melakukan pemeriksaan keselamatan setiap tahun. Untuk rincian lebih lanjut tentang pemeriksaan
keselamatan, silakan hubungi agen penjualan / distributor lokal Anda.
Rak Air Developer / Fixer 2~3 Rendam dalam air hangat dan bersihkan
bulan
Panduan Setiap hari Gunakan kain basah Pastikan plat sudah kering
Pemasangan plat
Peringatan
1) Saat membongkar rak, pastikan larutan kimia tidak bocor ke rak yang berdekatan.
2) Gunakan sikat untuk membersihkan kotoran yang mengkristal pada roda gigi.
3) Jangan gunakan sikat keras saat membersihkan rol. Ini akan merusak permukaan rol..
Check the DEV rack Is there any dirt on the DEV rack?
4
Are the gears and springs attached correctly?
Check the FIX rack Is there any dirt on the FIX rack?
5
Are the gears and springs attached correctly?
Check the Water rack Is there any dirt on the Water rack?
6
Are the gears and springs attached correctly?
Check the Dry rack Is there any dirt or crystallization of the solution?
7
Are the gears and springs attached correctly?
Check the cross over rack Check is there is any dirt or crystallization
8 (both)
Does the RRADY lamp Turn on the Power and check if the READY lamp will
9
turn on? turn on after temperature reaches the set temperature
Check the buzzer sound Check for the buzzer sound when the Power is turned
10
o and when the film is being processed.
Is the DEV temperature When the READY turns on, check the temperature of
11 set? DEV tank. The temperature should be 35 .
12 Use 1-2 films for testing Transportation test: check if the film is transported
16 Check for water supply Check if the water is running from the water tap
Check the dark room Make sure there is not any unnecessary items inside
19 the dark room. Make sure there is no light leakage.
Make sure the dark room lamp is working.
All the above inspections and checking will help keep the unit working and for better results.
12. Damage and Inspection
The operation does not Check if the insertion case is inserted Push the insertion case tightly.
stop when READY
Check for any light leakage touching the film Make sure there is no light to the insertion.
sensor.
There is abnormal sound Check the DEV / FIX / DRY rack are set Set all the racks properly
properly.
The films are not Check if the cross over guides are set Set the cross over guide properly.
transported
Check if the unit inside the racks turns Clean the racks
smoothly by hand.
Check if there is any oxidation.
The films comes out wet Check if the amount of Fixing Use the proper amount
Solution is enough or too little. Check the amount in tank.
Check if the solution is dirty and old. Change with new solution.
Image is light Check if the DEV and FIX solution is not Change the DEV solution
mixed.
Check the temperature of DEV solution Check the temperature of the Developer
Check if the amount of DEC solution Keep enough solution in Tank is enough.
Check if the DEV solution is not old. Change to new DEV Solution
Double image The film is exposed to the dark lamp Do not expose to the dark Change
Check if the dark room lamp filter is Correct. the light filter
Check if the insertion case is inserted Insert all the way to the end
Check if the insertion case lid is closed Close the lid completely
Irregular image Check if the level of the solution is correct Pour the correct amount
Is the level of solution even? Place the unit evenly to the ground.
Scratches on images Check for oxidation on insertion Clean off the oxidation
case and roller of each racks.
Are the films and cassettes used and handled Use them properly.
properly.
Image is too dark Check if the temperature of DEV is too high. Change to new solution
Was the solution mixed properly?
Films do not come out Check if the FIX solution is mixed properly. Change to new solution
smoothly Is the amount enough? Pour the correct amount
READY lamp does not turn The temperature of solution is not Rest the safety thermo
18
13 Spesifiksi Dasar :
Transportasi Sistem transportasi rol diagonal
Lingkungan Instalasi Suhu: 20C +/- 10C,Kelembaban: 55% +/- 25% Suhu
air: 5C lebih tinggi dari air keran
Berat 27.5kg
Pilihan Stand
Pompa air
Katup Solenoida
Kit filter air
Spesifikasi dapat berubah tanpa pemberitahuan sebelumnya untuk kinerja yang lebih baik.
19
14.Bagian Pilihan
14-1 Stand
Bangun stand sendiri untuk digunakan untuk ECOMAT9000 untuk digunakan di ruangan gelap
1. Setelah layanan
Jika ada masalah, silakan lihat halaman 22 Kerusakan dan Inspeksi. Hubungi agen / distributor
setempat Anda untuk instruksi lebih lanjut dan laporkan hal-hal berikut:
1) detail kerusakan (masalah)
2) nama model (ECOMAT 9000)
3) Tanggal pemasangan
4) Nomor seri peralatan
2. ECOMAT9000 diperiksa secara menyeluruh sebelum dikirim. Pastikan untuk menyimpan kartu
garansi dengan peralatan.
3. Setelah penggunaan normal peralatan, masa garansi 1 tahun setelah instalasi.
4. Garansi tidak berlaku jika peralatan tidak digunakan dengan benar.
5. Setiap penggantian atau biaya layanan setelah masa garansi akan dikenakan biaya. Silakan
hubungi agen / distributor lokal Anda untuk lebih jelasnya.
6. Pasokan suku cadang yang direkomendasikan akan dihentikan 7 tahun setelah pengumuman
penghentian. Namun, bahkan setelah 7 tahun pengumuman, masalah dapat diperbaiki. Sebaiknya
hubungi agen / distributor lokal Anda dalam hal demikian.
Agar unit tetap dalam kondisi baik, harap tinjau panduan ini untuk menjaga kinerja peralatan
dalam kondisi baik.