Fan Selector Glossary of Terms Used in Fan Selector
Overview Required Duty 
  This is the required duty point entered by the user. 
Downloads
Actual Duty 
This is the actual operaĕng duty for the fan. 
Fan Selector Help
Fan Input Power or Absorbed Power 
Making Fan Selecĕons This is the power consumed by the impeller – it excludes all
1. The Fan Selecĕons Screen
losses due to the internal contents of the unit – fans,
2. Entering the Required Duty
controls, power supplies etc. This is the power to be used in
Point the calculaĕon of Fan Efficiency. This is calculated at the
3. The Electrical Phase & Specific selected duty point for the fan. 
Fan Power Filter For a direct drive fan the Motor Output Power equals the
4. Choosing the Fan Ranges to Impeller Power which in Fan Selector as Fan Input Power or
Select From
Absorbed Power, i.e. the power absorbed by the impeller. 
5. Range Specific Addiĕonal
Parameters
Maximum Fan Input Power 
6. OEM Range Specific Parameters
This is the maximum power taken by the impeller on its
7. Making the Selecĕon
performance curve, unless the exact duty point is chosen
8. Selected Fans
where this occurs the Fan Input Power will always be lower. 
9. Displaying Fan Data
10. Selecĕng Ancillaries
Motor Input Power 
ISO5801:1997 (BS848 Pt: 1:1997) definiĕon: The electrical
Using Axial Configurator power supplied at the terminals of an electric motor drive. 
The difference between Motor Input Power and Fan Input
1. The Axial Configurator Screen
Power (Absorbed Power) are a measure of the losses both
2. Motor, Case & Impeller Opĕons mechanical and electrical within the motor. 
The Performance Curve Fan Selector calculates the Motor Input Power from the
tested Fan Input Power (Absorbed Power) and the motor
1. Understanding the Fan manufacturers quoted efficiency percentages. 
Performance Curve This is the power consumed by the equipment that you
actually pay for – it includes all losses due to the internal
Creaĕng Fan Data Sheets contents of the unit – fans, controls, power supplies etc.
1. Creaĕng Fan Data Sheets This is the power to be used in the calculaĕon of Specific
Fan Power. This is calculated at the selected duty point for
Building a Quotaĕon the fan. 
1. Adding to a Quotaĕon
Specific Fan Power 
2. The Quotaĕons Screen
Not actually a power raĕng, but a raĕo that quanĕfies how
3. The Quotaĕons Toolbar
much power is used to move a unit air quanĕty through a
4. Save as Excel
given HVAC system. It is quoted as Waĥs per litre per
Viewing Extra Literature second. The power used in this calculaĕon is the Motor
Input Power. 
1. Viewing Extra Literature for the
Selected Fan Nominal Motor Raĕng 
This is the rated power of the motor in accordance with IEC
Program Preferences
34‐1. 
1. Customizing the Programs 34‐1. 
Operaĕon For fans the Nominal Motor Power is taken as the raĕng for
the absorbed power of the fan. 
Glossary of Terms
1. Terms Used in Fan Selector Fan Efficiency 
The Fan Efficiency is the raĕo of the power transferred to
the airflow and the power used by the fan. It is calculated
  as the air volume flow (m³/s) mulĕplied by the total
  pressure (Pa) divided by the Fan Input Power. 
 
  Motor Efficiency 
Fan Selector quotes the motor manufacturers efficiency
percentages. 
 
 
 
 

    Copyright Nuaire 2014     |     Go to The Nuaire Group's main website: www.nuaire.co.uk