Sie sind auf Seite 1von 4

Project Data Sheet ABB ref. no.

*
Customer: [undefined] Date: 26.5.2016.
Handled by: [undefined]
Project name: [untitled] File name: [Untitled]
Customer ref. [untitled] Case: 1
Location: none Revision: A
Network: Short circuit power 200 MVA Ambient conditions:
Transformer: Type CTMP 7 H_ 3150-500 Altitude motor 1000 m
Primary voltage 6300 V Temp. motor 40 °C
Secondary Voltage 690 Altitude drive 1000 m
Frequency 50 Hz Temp. drive 40 °C
kVA rating (Sn) 3150 kVA Altitude transformer 1000 m
Impedance (zk) % 6,5 Temp. transformer 40 °C
Item Drive name Motor Type designation Drive Type designation
No. q'ty Motor q'ty Drive
1.1.1 [undefined] 1 AMI 500L4L 1 ACS880-07-2300A-7

Page 1 of 1
Project Technical Data Sheet ABB ref. no. *
Customer: [undefined] Date: 26.5.2016.
Handled by: [undefined]
Project name: [untitled] File name: [Untitled]
Customer ref. [untitled] Case: 1
Location: none Revision: A
Item Drive name Motors Load Speed range P Overload Motor nominal values construction Motor calculation result Drive Frequency converter Inu calculation
No. per type min base max [nbase] [nbase] [nmax] type Un fn Pn nn In cos eff. Tmax IM code IC Temp.rise Tcont Tmax Icont Imax q'ty In Imax Icont Imax
drive [rpm] [rpm] [rpm] [kW] [%] [%] [V] [Hz] [kW] [rpm] [A] phi [%] /Tn Insul. margin margin [A] [A] Type designation [A] [A] margin margin
1.1.1 [undefined] 1 Pump/fan load 1500 1500 1500 2050 100 100 AMI 500L4L 690 53 2.181 1.582 2.153 0,88 96,4 2,3 1001, B3 Special 81W B/F 0% 75% 2.153 2.153 1 ACS880-07-2300A-7 2300 7% 60%

Page 1 of 1
Drive Technical Data Sheet
Item No. 1.1.1 ACS880-07-2300A-7
Specifications Catalogue data
Name [undefined]
No.of Inverters 1 Voltage [V] 690
Type ACS880 Nominal power [kW] 2200
Construction Cabinet Nominal current [A] 2300
Cooling Air Imax [A] 3450
IP Class IP22 Ihd [A] 1720
Pulse 6-pulse Pulse 6
Frame type 3xD8T + 4xR8i
Icont max [A] 2300

Inverter load Calculations


Load type Pump/fan load Required Result Margin
Overload type Simple cyclic Limit
Icont [A] 2153 590s Icont [A] 2153 2300 7%
Imax [A] 2153 10s Imax [A] 2153 3450 60 %
cosfii Pmax kW 2127 3367 58 %
Temperature 8%

Selection method: IGBT temperature

Graph: currents
4000

3500

3000

2500
Current [A]

2000

1500

1000

500

0
0 200 400 600 800 1000 1200 1400 1600

Speed [rpm]
cont loadability max loadability cont load max load

Page 1 of 1
Motor Technical Data Sheet
Item No. 1.1.1 AMI 500L4L
Specifications DOL Catalogue data
Name [undefined] Product code Special
No.of motors 1 Voltage [V] 690
Motor type HXR, AMI, NXR Frequency [Hz] 53
Family AMI Power [kW] 2181
Polenumber Automatic Poles 4
Design Basic Speed [rpm] 1582
Connection Not specified Current [A] 2153
IP class IP55 Torque [Nm] 13165
IC class IC81W self ventilated, air-to-wTmax/Tn 2,3
IM class IM1001, B3(foot) Power factor 0,88
Max. speed rule Standard Efficiency [%] 96,4
Temp. rise B (<80 K) Temperature rise class B
Tmax margin 30% Insulation class F
Fwp Min/Rec/Max 53/53/53

Load type Pump/fan load Calculations Required Result Margin


Overload Type Simple Torque [Nm]
n min [rpm] 1500 n base 13051 13042 0%
n base [rpm] 1500 Power [kW]
n max [rpm] 1500 n base 2050 2049 0%
Pbase [kW] 2050 Overload [Nm]
Olbase [%] 100 n base 13051 22904 75 %
Olmax [%] 100
Temperature [°C] 40
Altitude [m] 1000
Ol definition: RMS 10min
1500-1500 rpm / 100 % 590s
1500-1500 rpm / 100 % 10s

Graph: load torques


25000

20000
Torque [Nm]

15000

10000

5000

0
0 200 400 600 800 1000 1200 1400 1600

Speed [rpm]
cont loadability max loadability cont load max load max load neg max loadability neg