Sie sind auf Seite 1von 1

Notes

1. All of elevation in meter


2. All of coordinate in meter
3. Nominal Concrete Cover = 40mm (external Face) and 40mm (internal Face)
to External Walls and 40mm for Internal Walls.
4. Minimum Reinforcement Lap Length or Tension Achorage (TA)
for Slabs
Top Bars Bottom Bars
38 x Dia for S10 To S16 27 x Dia for S10 To S16
54 x Dia for S19 To S40 38 x Dia for S19 To S40
For Walls
27 x Dia for S10 to S22
38 x Dia for S25 to S40
TA shall be measured from the Inner face of the transverse rebar.

6. Concrete Grade shall be 40N/mm Characteristic Cube Strength at 28 Days.


7. All Beam's Horizontal Rebar shall be Anchored at the ends to the Supporting
ends.

Key to symbols

1 1 1

Reference drawings

1 13/12/2017 YS Issued For Approval RB IT

0 05/05/2017 AF Issued For Review AS IT

Rev Date Drawn Description


Designer :

Client :

Title :
Wisma Sudirman Access Tunnel
Section K1-K1 & Knock Out Panel Details
Reinforcement Details

Designed AG Eng check RB


Drawn YS Coordinator IT
Dwg check NY Approved IT
Scale at A1 Status Rev

Mott MacDonald
1:50, 1:20 APR 1
Drawing Number
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.
We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties. 383363/STR/STN/0074