1-10 V-Dim
ECG versions
Model Order no. Output currents 1) Output power
CCD435-70LS-01/220-240/1-10V 10079000 4 x 350 mA max. 70 W
CCD470-140LS-01/220-240/1-10V 10079004 4 x 700 mA max. 140 W
CCD435-70LS-01/220-240/DALI 10079001 4 x 350 mA max. 70 W
CCD470-140LS-01/220-240/DALI 10079005 4 x 700 mA max. 140 W
1)
Additional output currents can be selected by parallel connection of the outputs of the ECG, see table „Selectable output currents“
Temperatures (operation)
Model Ambient (ta) Case (tc)
CCD435-70LS... – 25 °C ... + 60 °C max. + 80 °C
CCD470-140LS... – 25 °C ... + 50 °C max. + 80 °C
LS-Typ 10 A 16 A 20 A 25 A I[A]
CCD435-70LS.... B 5 9 11 14 I peak
62 A / 220 μs
CCD470-140LS... C 9 15 19 24
Operating data
Model Input Input Power ECG Output Output voltage / Total output
current 1) power 1) factor 1) efficiency 1) currents 4) channel power 2), 3)
A % V V W
CCD435-70LS... 0,36 76 0,98 92 4 x 350 mA 15 ... 50 20 ... 70
CCD470-140LS... 0,72 150 0,98 93 4 x 700 mA 10 ... 50 28 ... 140
1)
All specifications with 230 VAC nominal operation and 100 % load
2)
Power output in undimmed operation should not go below 10 % of the maximum permissible value
3)
Asymmetric load distribution on the outputs is permissible
4)
Further output currents can be selected via parallel switching of the ECG outputs, see the table „Selectable output currents“
DA
DA
DA DA
Push-DIM
DA DA
n.c. n.c.
–
1-10 V
+
n.c.
more ECG
+
CH1: LED
–
+
CH2: LED
–
+
CH3: LED
–
+
CH4: LED
–
+ +
CH1: LED CH1: LED
– –
+ +
CH2: LED CH2: LED
– –
+ +
CH3: LED CH3: LED
– –
+ +
CH4: LED CH4: LED
– –
+ +
CH1: LED CH1: LED
– –
+ +
CH2: LED CH2: LED
– –
+ +
CH3: LED CH3: LED
– –
+ +
CH4: LED CH4: LED
– –
0,95
90
Efficiency [%]
Power Factor
0,9
80
0,85
70
CCD435… 0,8 CCD435…
CCD470… CCD470…
60 0,75
20 40 60 80 100 20 40 60 80 100
Total load on ECG outputs [%] Total load on ECG outputs [%]
Short button press Switching on of LEDs to the last dimming level Switching off of LEDs and saving of current dimming level;
(memory function) ECG in standby mode
Long button press Switching on of LEDs to the last dimming level and Dimming up or dimming down of LEDs; each release and re-
then dimming up or dimming down pressing of the button reverses the dimming direction
Activation or deactivation of the recovery function is by pressing and holding the push-button connected to the DALI interface and with
the lighting system switched on.
Activation of the recovery Press and hold the push-button for approximately 20 s until the lighting is dimmed down to 1 %
function: luminous flux. When the push-button is then released the recovery function is activated.
Deactivation of the recovery Press and hold the push-button for approximately 25 s until the lighting is increased to 100 % lumi-
function: nous flux. When the push-button is then released the recovery function is deactivated.
Luminous flux
100 %
1%
Time duration
10 s 20 s 25 s
Synchronising Recovery function activated Recovery function deactivated
ECG dimensions
ZM
Model X XM Y Z ZM
Z
mm mm mm mm mm
CCD435-70LS... 360 350 39 21 9
Y
CCD470-140LS... 360 350 39 21 9
XM
X
Logistic data
Model Order no. EAN Weight ECG Dimensions Weight
ECG PU 1) PU 1) PU 1)
kg St. mm kg
CCD435-70LS-01/220-240/1-10V 10079000 4046189027403 0,395 30
CCD470-140LS-01/220-240/1-10V 10079004 4046189027441 0,395 30
CCD435-70LS-01/220-240/DALI 10079001 4046189027410 0,395 30
CCD470-140LS-01/220-240/DALI 10079005 4046189027458 0,395 30
1)
Packaging unit