Sie sind auf Seite 1von 37

L11B

Managed Area MO Class Name Parameter Name


Radio_Network ReportConfigEUtraBadCovPrim a2ThresholdRsrpPrim

Radio_Network ReportConfigEUtraBadCovPrim a2ThresholdRsrqPrim

Radio_Network ReportConfigEUtraBadCovPrim hysteresisA2Prim

Radio_Network ReportConfigEUtraBadCovPrim reportAmountA2Prim

Radio_Network ReportConfigEUtraBadCovPrim reportIntervalA2Prim


Radio_Network ReportConfigEUtraBadCovPrim reportQuantityA2Prim

Radio_Network ReportConfigEUtraBadCovPrim timeToTriggerA2Prim

Radio_Network ReportConfigEUtraBadCovPrim triggerQuantityA2Prim

Radio_Network ReportConfigEUtraBadCovPrim ReportConfigEUtraBadCovPrimId

Radio_Network ReportConfigEUtraBadCovSec a2ThresholdRsrpSec

Radio_Network ReportConfigEUtraBadCovSec a2ThresholdRsrqSec

Radio_Network ReportConfigEUtraBadCovSec hysteresisA2Sec

Radio_Network ReportConfigEUtraBadCovSec reportAmountA2Sec


Radio_Network ReportConfigEUtraBadCovSec reportIntervalA2Sec

Radio_Network ReportConfigEUtraBadCovSec reportQuantityA2Sec

Radio_Network ReportConfigEUtraBadCovSec timeToTriggerA2Sec

Radio_Network ReportConfigEUtraBadCovSec triggerQuantityA2Sec

Radio_Network ReportConfigEUtraBadCovSec ReportConfigEUtraBadCovSecId

Radio_Network ReportConfigEUtraBestCell a3offset

Radio_Network ReportConfigEUtraBestCell hysteresisA3

Radio_Network ReportConfigEUtraBestCell reportAmountA3


Radio_Network ReportConfigEUtraBestCell reportIntervalA3

Radio_Network ReportConfigEUtraBestCell reportQuantityA3

Radio_Network ReportConfigEUtraBestCell timeToTriggerA3

Radio_Network ReportConfigEUtraBestCell triggerQuantityA3

Radio_Network ReportConfigEUtraBestCell ReportConfigEUtraBestCellId

Radio_Network ReportConfigEUtraIntraFreqPm measSelectionEUtraPm

Radio_Network ReportConfigEUtraIntraFreqPm a1ThresholdRsrpPm


Radio_Network ReportConfigEUtraIntraFreqPm a1ThresholdRsrqPm

Radio_Network ReportConfigEUtraIntraFreqPm a2ThresholdRsrpPm

Radio_Network ReportConfigEUtraIntraFreqPm a2ThresholdRsrqPm

Radio_Network ReportConfigEUtraIntraFreqPm a3OffsetPm

Radio_Network ReportConfigEUtraIntraFreqPm a3ReportOnLeavePm

Radio_Network ReportConfigEUtraIntraFreqPm a4ThresholdRsrpPm

Radio_Network ReportConfigEUtraIntraFreqPm a4ThresholdRsrqPm

Radio_Network ReportConfigEUtraIntraFreqPm a5ThresholdRsrpPm1

Radio_Network ReportConfigEUtraIntraFreqPm a5ThresholdRsrqPm1

Radio_Network ReportConfigEUtraIntraFreqPm a5ThresholdRsrpPm2

Radio_Network ReportConfigEUtraIntraFreqPm a5ThresholdRsrqPm2

Radio_Network ReportConfigEUtraIntraFreqPm triggerQuantityPm

Radio_Network ReportConfigEUtraIntraFreqPm hysteresisPm

Radio_Network ReportConfigEUtraIntraFreqPm timeToTriggerPm


Radio_Network ReportConfigEUtraIntraFreqPm reportQuantityPm

Radio_Network ReportConfigEUtraIntraFreqPm maxReportCellsPm

Radio_Network ReportConfigEUtraIntraFreqPm reportIntervalPm

Radio_Network ReportConfigEUtraIntraFreqPm reportAmountPm

Radio_Network ReportConfigEUtraIntraFreqPm reservedBy

Radio_Network ReportConfigEUtraIntraFreqPm ReportConfigEUtraIntraFreqPmId

Radio_Network ReportConfigA1Prim ReportConfigA1PrimId


Radio_Network ReportConfigA1Prim a1ThresholdRsrpPrim

Radio_Network ReportConfigA1Prim a1ThresholdRsrqPrim

Radio_Network ReportConfigA1Prim hysteresisA1Prim


Radio_Network ReportConfigA1Prim timeToTriggerA1Prim

Radio_Network ReportConfigA1Sec ReportConfigA1SecId


Radio_Network ReportConfigA1Sec a1ThresholdRsrpSec
Radio_Network ReportConfigA1Sec a1ThresholdRsrqSec

Radio_Network ReportConfigA1Sec hysteresisA1Sec


Radio_Network ReportConfigA1Sec timeToTriggerA1Sec

Radio_Network ReportConfigA5 ReportConfigA5Id


Radio_Network ReportConfigA5 a5Threshold1Rsrp

Radio_Network ReportConfigA5 a5Threshold2Rsrp

Radio_Network ReportConfigA5 a5Threshold1Rsrq

Radio_Network ReportConfigA5 a5Threshold2Rsrq

Radio_Network ReportConfigA5 hysteresisA5


Radio_Network ReportConfigA5 timeToTriggerA5

Radio_Network ReportConfigA5 triggerQuantityA5

Radio_Network ReportConfigB2Utra ReportConfigB2UtraId


Radio_Network ReportConfigB2Utra b2Threshold1Rsrp

Radio_Network ReportConfigB2Utra b2Threshold1Rsrq

Radio_Network ReportConfigB2Utra b2Threshold2RscpUtra

Radio_Network ReportConfigB2Utra b2Threshold2EcNoUtra

Radio_Network ReportConfigB2Utra hysteresisB2


Radio_Network ReportConfigB2Utra timeToTriggerB2
Radio_Network ReportConfigB2Utra triggerQuantityB2

Radio_Network ReportConfigB2Utra triggerQuantityUtraB2

Radio_Network ReportConfigB2Geran ReportConfigB2GeranId


Radio_Network ReportConfigB2Geran b2Threshold1Rsrp

Radio_Network ReportConfigB2Geran b2Threshold1Rsrq

Radio_Network ReportConfigB2Geran b2Threshold2Geran

Radio_Network ReportConfigB2Geran hysteresisB2


Radio_Network ReportConfigB2Geran timeToTriggerB2

Radio_Network ReportConfigB2Geran triggerQuantityB2

Radio_Network ReportConfigB2Cdma2000 ReportConfigB2Cdma2000Id


Radio_Network ReportConfigB2Cdma2000 b2Threshold1Rsrp

Radio_Network ReportConfigB2Cdma2000 b2Threshold1Rsrq

Radio_Network ReportConfigB2Cdma2000 b2Threshold2Cdma2000

Radio_Network ReportConfigB2Cdma2000 hysteresisB2


Radio_Network ReportConfigB2Cdma2000 timeToTriggerB2

Radio_Network ReportConfigB2Cdma2000 triggerQuantityB2

Radio_Network ReportConfigA5Anr ReportConfigA5AnrId


Radio_Network ReportConfigA5Anr a5Threshold1RsrpAnrDelta

Radio_Network ReportConfigA5Anr a5Threshold2RsrpAnrDelta

Radio_Network ReportConfigA5Anr a5Threshold1RsrqAnrDelta


Radio_Network ReportConfigA5Anr a5Threshold2RsrqAnrDelta

Radio_Network ReportConfigA5Anr timeToTriggerA5

Radio_Network ReportConfigA5Anr hysteresisA5


Radio_Network ReportConfigEUtraBestCellAnr a3offsetAnrDelta

Radio_Network ReportConfigEUtraBestCellAnr hysteresisA3


Radio_Network ReportConfigEUtraBestCellAnr ReportConfigEUtraBestCellAnrId
Radio_Network ReportConfigEUtraBestCellAnr timeToTriggerA3
ERICSSON

Parameter Description Data Type Range and Values


The primary Reference Signal Received Power (RSRP) threshold value long -140..-44
for eventA2. Used only when triggerQuantityA2Prim is set to RSRP.
Primary and secondary measurement attributes refer to the option to use
different settings for two simultaneous measurements for eventA2. See
description of the attribute badCoverageMeasSelection for further details.

The primary Reference Signal Received Quality (RSRQ) threshold value long -195..-30
for eventA2. Used only when triggerQuantityA2Prim is set to RSRQ.
Primary and secondary measurement attributes refer to the option to use
different settings for two simultaneous measurements for eventA2. See
description of the attribute badCoverageMeasSelection for further details.

The hysteresis value for the primary eventA2 measurement. Primary and long 0..150
secondary measurement parameters refer to the option to use different
settings for two simultaneous measurements for eventA2. See description
of attribute “badCoverageMeasSelection” for further details.

The number of reports for periodical reporting for the primary eventA2 long 0,1,2,4,8,16,32,64
measurement .
Value 0 means that reports are sent as long as the event is fulfilled.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.

The interval for event triggered periodical reporting for the primary ReportInter MS_120
eventA2 measurement. Primary and secondary measurement parameters val MS_240
refer to the option to use different settings for two simultaneous MS_480
measurements for eventA2. See description of attribute MS_640
“badCoverageMeasSelection” for further details. MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048
The quantities to include in the measurement report for the primary ReportQua SAME_AS_TRIGGER_
eventA2 measurement. ntity QUANTITY
The value 0 - sameAsTriggerQuantity means that the same quantity as BOTH
triggerQuantity is included in the measurement report.
The value 1 - both means that both Reference Symbol Received Power
(RSRP) and Reference Symbol Received Quality (RSRQ) quantities are
included in the measurement report.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of parameter badCoverageMeasSelection for further
details.

The time-to-trigger value for the primary eventA2 measurement. Primary long 0,40,64,80,100,128,160
and secondary measurement parameters refer to the option to use ,256,320,480,512,640,1
different settings for two simultaneous measurements for eventA2. See 024,1280,2560,5120
description of attribute badCoverageMeasSelection for further details.

The quantity that triggers the eventA2 for the primary eventA2 TriggerQua RSRP
measurement. Primary and secondary measurement parameters refer to ntity RSRQ
the option to use different settings for two simultaneous measurements for
eventA2. See description of attribute “badCoverageMeasSelection” for
further details.

The value component of the Relative Distinguished Name (RDN). string

The secondary Reference Signal Received Power (RSRP) threshold long -140..-44
value for eventA2. Only used if triggerQuantityA2Sec is set to RSRP.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.

The secondary Reference Signal Received Quality (RSRQ) threshold long -195..-30
value for eventA2. Only used if triggerQuantityA2Sec is set to RSRQ.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.

The hysteresis value for the secondary eventA2 measurement. Primary long 0..150
and secondary measurement parameters refer to the option to use
different settings for two simultaneous measurements for eventA2. See
description of attribute “badCoverageMeasSelection” for further details.

Number of reports for periodical reporting for the secondary eventA2 long 0,1,2,4,8,16,32,64
measurement.
Value 0 means that reports are sent as long as the event is fulfilled.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute badCoverageMeasSelection for further details.
The interval for event-triggered periodical reporting for the secondary ReportInter MS_120
eventA2 measurement. Primary and secondary measurement parameters val MS_240
refer to the option to use different settings for two simultaneous MS_480
measurements for eventA2. See description of attribute MS_640
badCoverageMeasSelection for further details. MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048

The quantities to include in the measurement report for the secondary ReportQua SAME_AS_TRIGGER_
eventA2 measurement. ntity QUANTITY
BOTH
The value 0, sameAsTriggerQuantity, means that the same quantity as
triggerQuantity is included in the measurement report.

The value 1, both, means that both RSRP and RSRQ quantities are
included in the measurement report.

Primary and secondary measurement parameters refer to the option to


use different settings for two simultaneous measurements for eventA2.
See description of attribute badCoverageMeasSelection for further details.

The time to trigger value for the secondary eventA2 measurement. long 0,40,64,80,100,128,160
Primary and secondary measurement parameters refer to the option to ,256,320,480,512,640,1
use different settings for two simultaneous measurements for eventA2. 024,1280,2560,5120
See description of attribute “badCoverageMeasSelection” for further
details.

The quantity that triggers the eventA2 for the secondary eventA2 TriggerQua RSRP
measurement. Primary and secondary measurement parameters refer to ntity RSRQ
the option to use different settings for two simultaneous measurements for
eventA2. See description of attribute “badCoverageMeasSelection” for
further details.

The value component of the Relative Distinguished Name (RDN). string

The offset value for eventA3. long -150..150

The hysteresis value for eventA3. long 0..150

Number of reports when periodical reporting is used. long 0,1,2,4,8,16,32,64


Value of 0 means that reports are sent as long as the event is fulfilled.
The interval for event triggered periodical reporting. ReportInter MS_120
val MS_240
MS_480
MS_640
MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048

The quantities to include in the measurement report. ReportQua SAME_AS_TRIGGER_


ntity QUANTITY
BOTH

The time to trigger value for eventA3. long 0,40,64,80,100,128,160


,256,320,480,512,640,1
024,1280,2560,5120
The quantity that triggers the event. TriggerQua RSRP
ntity RSRQ

The value component of the Relative Distinguished Name (RDN). string

The type of measurement for which this MO is currently configured. The MeasSelect PERIODICAL
options A1-A5 correspond to respective thresholds/offsets that trigger ionEUtra EVENT_A1
these events. EVENT_A2
EVENT_A3
Selecting PERIODICAL results in periodical measurement reports with no EVENT_A4
specific trigger. PERIODICAL measurement reporting is limited to EVENT_A5
reporting the strongest cells.

The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA1 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A1.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA1 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A1.
The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA2 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A2.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA2 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A2.
The offset value for eventA3, for PM Initiated UE Measurements. long -150..150
Only used if measSelectionEUtraPm is set to EVENT_A3.

Indicates that the UE initiates the measurement reporting procedure when boolean
the leaving condition is met for a cell. Used only when
measSelectionEUtraPm is set to EVENT_A3.
The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA4 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A4.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA4 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A4.
The Reference Signal Received Power (RSRP) threshold 1 value for long -140..-44
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Quality (RSRQ) threshold 1 value for long -195..-30
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Power (RSRP) threshold 2 value for long -140..-44
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Quality (RSRQ) threshold 2 value for long -195..-30
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Power (RSRP) or Reference Signal TriggerQua RSRP
Received Quality (RSRQ) quantity that triggers the PM-initiated E-UTRA ntity RSRQ
measurements.
The hysteresis value for the condition triggering the entering and leaving long 0..150
measurement report for PM-Initiated UE Measurements. Used only when
measSelectionEUtraPm is set to EVENT_A1, EVENT_A2, EVENT_A3,
EVENT_A4 or EVENT_A5.
Time during which specific event criteria must be met to trigger a long 0,40,64,80,100,128,160
measurement report for PM-Initiated UE Measurements. Used only when ,256,320,480,512,640,1
measSelectionEUtraPm is set to EVENT_A1, EVENT_A2, EVENT_A3, 024,1280,2560,5120
EVENT_A4 or EVENT_A5.
The quantities to include in the measurement report for PM-Initiated UE ReportQua SAME_AS_TRIGGER_
Measurements. ntity QUANTITY
BOTH
The value 0, sameAsTriggerQuantity, means that the same quantity as
triggerQuantityPm is included in the measurement report.

The value 1, both, means that both Reference Signal Received Power
(RSRP) and Reference Signal Received Quality (RSRQ) quantities are
included in the measurement report.

Maximum number of cells to include in the measurement report for the long 1..8
PM Initiated UE Measurements.

The interval for event-triggered periodical reporting for PM-Initiated UE ReportInter MS_120
Measurements. val MS_240
MS_480
MS_640
MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048

The number of periodical reports for PM-Initiated UE Measurements. long 0,1,2,4,8,16,32,64


Value 0 means that reports are sent as long as the event is fulfilled.
Contains a list of MO instances that reserve this MO instance. ManagedO
bject

The value component of the Relative Distinguished Name (RDN). string

The value component of the Relative Distinguished Name (RDN). string


The Reference Signal Received Power (RSRP) threshold value for the long -140..-44
primary eventA1.

The Reference Signal Received Quality (RSRQ) threshold value for the long -195..-30
primary eventA1.

The hysteresis value for the primary eventA1 measurement. long 0..150
The time-to-trigger value for the primary eventA1 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The value component of the Relative Distinguished Name (RDN). string
The Reference Signal Received Power (RSRP) threshold value for the long -140..-44
secondary eventA1.
The Reference Signal Received Quality (RSRQ) threshold value for the long -195..-30
secondary eventA1.

The hysteresis value for the secondary eventA1 measurement. long 0..150
The time-to-trigger value for the secondary eventA1 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The value component of the Relative Distinguished Name (RDN). string
The Reference Signal Received Power (RSRP) threshold1 value for long -140..-44
eventA5.

The Reference Signal Received Power (RSRP) threshold2 value for long -140..-44
eventA5.

The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventA5.

The Reference Signal Received Quality (RSRQ) threshold2 value for long -195..-30
eventA5.

The hysteresis value for the eventA5 measurement. long 0..150


The time-to-trigger value for the eventA5 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity that triggers the eventA5 for the eventA5 measurement. TriggerQua RSRP
ntity RSRQ

The value component of the Relative Distinguished Name (RDN). string


The Reference Signal Received Power (RSRP) threshold1 value for long -140..-44
eventB2.

The Reference Signal Received Quality (RSRQ) in the threshold1 value long -195..-30
for eventB2.

Received Signal Code Power in the ThresholdUTRA, threshold2 value for long -120..-24
eventB2.

Ratio of energy per modulation bit to noise spectral density in the long -245..0
ThresholdUTRA, threshold2 value for eventB2.
Not applicable for UTRA TDD.

The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ

The quantity for threshold2 (neighbor UTRA cell) that is sent to the UE, TriggerQua RSCP
and is used by the UE together with threshold1 to trigger the eventB2. ntityUtra ECNO

The value component of the Relative Distinguished Name (RDN). string


The Reference Signal Received Power (RSRP) threshold1 value for long -140..-44
eventB2.

The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventB2.

The Signal Quality in the ThresholdGERAN, threshold2 value for eventB2. long -110..-47

The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ

The value component of the Relative Distinguished Name (RDN). string


The Reference Signal Received Power (RSRP) threshold1 value for long -140..-44
eventB2.

The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventB2.

The Signal Quality in the thresholdCDMA2000, threshold2 value for long -310..0
eventB2.
The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ

The value component of the Relative Distinguished Name (RDN). string


This parameter together with a5Threshold1Rsrp specifies "The Reference long -10..10
Signal Received Power (RSRP) threshold1 value for eventA5." . The
equation for calculating the RSRP threshold1 value for ANR is
a5Threshold1Rsrp + a5Threshold1RsrpAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRP.

This parameter together with a5Threshold2Rsrp specifies "The Reference long -10..10
Signal Received Power (RSRP) threshold2 value for eventA5." . The
equation for calculating the RSRP threshold2 value for ANR is
a5Threshold2Rsrp - a5Threshold2RsrpAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRP.

This parameter together with a5Threshold1Rsrq specifies "The Reference long -10..10
Signal Received Quality (RSRQ) threshold1 value for eventA5." . The
equation for calculating the RSRQ threshold1 value for ANR is
a5Threshold1Rsrq + a5Threshold1RsrqAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRQ.
This parameter together with a5Threshold2Rsrq specifies "The Reference long -10..10
Signal Received Quality (RSRQ) threshold2 value for eventA5." . The
equation for calculating the RSRQ threshold2 value for ANR is
a5Threshold2Rsrq -a5Threshold2RsrqAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRQ.

The time-to-trigger value for the eventA5 measurement. long 0,40,64,80,100,128,160


,256,320,480,512,640,1
024,1280,2560,5120
The hysteresis value for the eventA5 measurement. long 0..150
The offset value for eventA3. Dependent on reportQuantityA3 on MO long -10..10
ReportConfigEUtraBestCell and is a delta towards a3offset on
reportQuantityA3, The a3ofsett used in the ANR measure is calculated as
a3offset (on ReportConfigEUtraBestCell) - a3offset AnrDelta

The hysteresis value for eventA3. long 0..150


The value component of the Relative Distinguished Name (RDN). string
The time to trigger value for eventA3. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
Change Take Effect
Default Value Unit Resolution ReadOnly Restricted Mandatory Persistent
-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

10 0.1 dB 5 false false false true New connection

0 false false false true New connection

MS_480 false false false true New connection


BOTH false false false true New connection

640 ms false false false true New connection

RSRP false false false true New connection

false true true true

-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

10 0.1 dB 5 false false false true New connection

0 false false false true New connection


MS_480 false false false true New connection

BOTH false false false true New connection

640 ms false false false true New connection

RSRQ false false false true New connection

false true true true

30 0.1 dB 5 false false false true New connection

10 0.1 dB 5 false false false true New connection

0 false false false true New connection


MS_480 false false false true New connection

BOTH false false false true New connection

40 ms false false false true New connection

RSRP false false false true New connection

false true true true

PERIODICAL false false false true New connection

-140 dBm 1 false false false true New connection


-195 0.1 dB 1 false false false true New connection

-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

5 0.1 dB 5 false false false true New connection

false false false false true New connection

-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

-140 dBm 1 false false false true New connection

-195 0.1 dB 1 false false false true New connection

RSRP false false false true New connection

10 0.1 dB 5 false false false true New connection

640 ms false false false true New connection


BOTH false false false true New connection

4 1 false false false true New connection

MS_480 false false false true New connection

0 false false false true New connection

true false false true

false true true true

false true true true


-136 1 dBm false false false true New connection

-192 0.1 dB false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection

false true true true


-136 1 dBm false false false true New connection
-192 0.1 dB false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection

false true true true


-140 1 dBm false false false true New connection

-136 1 dBm false false false true New connection

-195 0.1 dB false false false true New connection

-192 0.1 dB false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection

RSRP false false false true New connection

false true true true


-140 1 dBm false false false true New connection

-195 0.1 dB false false false true New connection

-115 1 dBm false false false true New connection

-240 0.1 dB 5 false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection
RSRP false false false true New connection

RSCP false false false true New connection

false true true true


-140 1 dBm false false false true New connection

-195 0.1 dB false false false true New connection

-110 1 dBm false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection

RSRP false false false true New connection

false true true true


-140 1 dBm false false false true New connection

-195 0.1 dB false false false true New connection

-15 0.5 dB 5 false false false true New connection

10 0.1 dB 5 false false false true New connection


640 false false false true New connection

RSRP false false false true New connection

false true true true Immediately


1 1 dBm 1 false false false true New connection

1 1 dBm 1 false false false true New connection

10 0.1 dB 1 false false false true New connection


10 0.1 dB 1 false false false true New connection

640 false false false true New connection

10 0.1 dB 5 false false false true New connection


1 1 dBm 1 false false false true New connection

10 0.1 dB 5 false false false true New connection


false true true true Immediately
640 false false false true New connection
Disturbances Dependencies Bulk CM included
The value
sameAsTriggerQ
uantity means
that the same
quantity as
triggerQuantity is
to be included in
the measurement
report.
The value both
means that both
RSRP and RSRQ
quantities is to be
included in the
measurement
report.
The managed
object cannot be
deleted if it is
reserved.

Only used if
triggerQuantityA1
Prim is set to
RSRP.
Only used if
triggerQuantityA1
Prim is set to
RSRQ.

Only used if
triggerQuantityA1
Sec is set to
RSRP.
Only used if
triggerQuantityA1
Sec is set to
RSRQ.

Only used if
triggerQuantityA5
is set to RSRP.

Only used if
triggerQuantityA5
is set to RSRP.

Only used if
triggerQuantityA5
is set to RSRQ.

Only used if
triggerQuantityA5
is set to RSRQ.

Only used if
triggerQuantityB2
is set to RSRP.

Only used if
triggerQuantityB2
is set to RSRQ.

Only used when


measQuantityUtr
aFDD is set to
RSCP
Only used when
measQuantityUtr
aFDD is set to
ECNO
Only used if
triggerQuantityB2
is set to RSRP.

Only used if
triggerQuantityB2
is set to RSRQ.

Only used if
triggerQuantityB2
is set to RSRP.

Only used if
triggerQuantityB2
is set to RSRQ.
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE

Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE

Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE

Not pure
dependence
towards
parameter on
ReportConfigEUtr
aBestCell Mo, but
there should be a
check that this
attribute and
corresponding
attribute on
ReportConfigEUtr
aBestCell MO
together sends
out a valid
number to the UE

Das könnte Ihnen auch gefallen