The primary Reference Signal Received Quality (RSRQ) threshold value long -195..-30
for eventA2. Used only when triggerQuantityA2Prim is set to RSRQ.
Primary and secondary measurement attributes refer to the option to use
different settings for two simultaneous measurements for eventA2. See
description of the attribute badCoverageMeasSelection for further details.
The hysteresis value for the primary eventA2 measurement. Primary and long 0..150
secondary measurement parameters refer to the option to use different
settings for two simultaneous measurements for eventA2. See description
of attribute “badCoverageMeasSelection” for further details.
The number of reports for periodical reporting for the primary eventA2 long 0,1,2,4,8,16,32,64
measurement .
Value 0 means that reports are sent as long as the event is fulfilled.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.
The interval for event triggered periodical reporting for the primary ReportInter MS_120
eventA2 measurement. Primary and secondary measurement parameters val MS_240
refer to the option to use different settings for two simultaneous MS_480
measurements for eventA2. See description of attribute MS_640
“badCoverageMeasSelection” for further details. MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048
The quantities to include in the measurement report for the primary ReportQua SAME_AS_TRIGGER_
eventA2 measurement. ntity QUANTITY
The value 0 - sameAsTriggerQuantity means that the same quantity as BOTH
triggerQuantity is included in the measurement report.
The value 1 - both means that both Reference Symbol Received Power
(RSRP) and Reference Symbol Received Quality (RSRQ) quantities are
included in the measurement report.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of parameter badCoverageMeasSelection for further
details.
The time-to-trigger value for the primary eventA2 measurement. Primary long 0,40,64,80,100,128,160
and secondary measurement parameters refer to the option to use ,256,320,480,512,640,1
different settings for two simultaneous measurements for eventA2. See 024,1280,2560,5120
description of attribute badCoverageMeasSelection for further details.
The quantity that triggers the eventA2 for the primary eventA2 TriggerQua RSRP
measurement. Primary and secondary measurement parameters refer to ntity RSRQ
the option to use different settings for two simultaneous measurements for
eventA2. See description of attribute “badCoverageMeasSelection” for
further details.
The secondary Reference Signal Received Power (RSRP) threshold long -140..-44
value for eventA2. Only used if triggerQuantityA2Sec is set to RSRP.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.
The secondary Reference Signal Received Quality (RSRQ) threshold long -195..-30
value for eventA2. Only used if triggerQuantityA2Sec is set to RSRQ.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute “badCoverageMeasSelection” for further
details.
The hysteresis value for the secondary eventA2 measurement. Primary long 0..150
and secondary measurement parameters refer to the option to use
different settings for two simultaneous measurements for eventA2. See
description of attribute “badCoverageMeasSelection” for further details.
Number of reports for periodical reporting for the secondary eventA2 long 0,1,2,4,8,16,32,64
measurement.
Value 0 means that reports are sent as long as the event is fulfilled.
Primary and secondary measurement parameters refer to the option to
use different settings for two simultaneous measurements for eventA2.
See description of attribute badCoverageMeasSelection for further details.
The interval for event-triggered periodical reporting for the secondary ReportInter MS_120
eventA2 measurement. Primary and secondary measurement parameters val MS_240
refer to the option to use different settings for two simultaneous MS_480
measurements for eventA2. See description of attribute MS_640
badCoverageMeasSelection for further details. MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048
The quantities to include in the measurement report for the secondary ReportQua SAME_AS_TRIGGER_
eventA2 measurement. ntity QUANTITY
BOTH
The value 0, sameAsTriggerQuantity, means that the same quantity as
triggerQuantity is included in the measurement report.
The value 1, both, means that both RSRP and RSRQ quantities are
included in the measurement report.
The time to trigger value for the secondary eventA2 measurement. long 0,40,64,80,100,128,160
Primary and secondary measurement parameters refer to the option to ,256,320,480,512,640,1
use different settings for two simultaneous measurements for eventA2. 024,1280,2560,5120
See description of attribute “badCoverageMeasSelection” for further
details.
The quantity that triggers the eventA2 for the secondary eventA2 TriggerQua RSRP
measurement. Primary and secondary measurement parameters refer to ntity RSRQ
the option to use different settings for two simultaneous measurements for
eventA2. See description of attribute “badCoverageMeasSelection” for
further details.
The type of measurement for which this MO is currently configured. The MeasSelect PERIODICAL
options A1-A5 correspond to respective thresholds/offsets that trigger ionEUtra EVENT_A1
these events. EVENT_A2
EVENT_A3
Selecting PERIODICAL results in periodical measurement reports with no EVENT_A4
specific trigger. PERIODICAL measurement reporting is limited to EVENT_A5
reporting the strongest cells.
The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA1 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A1.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA1 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A1.
The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA2 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A2.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA2 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A2.
The offset value for eventA3, for PM Initiated UE Measurements. long -150..150
Only used if measSelectionEUtraPm is set to EVENT_A3.
Indicates that the UE initiates the measurement reporting procedure when boolean
the leaving condition is met for a cell. Used only when
measSelectionEUtraPm is set to EVENT_A3.
The Reference Signal Received Power (RSRP) threshold value for long -140..-44
eventA4 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A4.
The Reference Signal Received Quality (RSRQ) threshold value for long -195..-30
eventA4 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A4.
The Reference Signal Received Power (RSRP) threshold 1 value for long -140..-44
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Quality (RSRQ) threshold 1 value for long -195..-30
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Power (RSRP) threshold 2 value for long -140..-44
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRP and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Quality (RSRQ) threshold 2 value for long -195..-30
eventA5 for PM-Initiated UE Measurements. Used only when
triggerQuantityPm is set to RSRQ and measSelectionEUtraPm is set to
EVENT_A5.
The Reference Signal Received Power (RSRP) or Reference Signal TriggerQua RSRP
Received Quality (RSRQ) quantity that triggers the PM-initiated E-UTRA ntity RSRQ
measurements.
The hysteresis value for the condition triggering the entering and leaving long 0..150
measurement report for PM-Initiated UE Measurements. Used only when
measSelectionEUtraPm is set to EVENT_A1, EVENT_A2, EVENT_A3,
EVENT_A4 or EVENT_A5.
Time during which specific event criteria must be met to trigger a long 0,40,64,80,100,128,160
measurement report for PM-Initiated UE Measurements. Used only when ,256,320,480,512,640,1
measSelectionEUtraPm is set to EVENT_A1, EVENT_A2, EVENT_A3, 024,1280,2560,5120
EVENT_A4 or EVENT_A5.
The quantities to include in the measurement report for PM-Initiated UE ReportQua SAME_AS_TRIGGER_
Measurements. ntity QUANTITY
BOTH
The value 0, sameAsTriggerQuantity, means that the same quantity as
triggerQuantityPm is included in the measurement report.
The value 1, both, means that both Reference Signal Received Power
(RSRP) and Reference Signal Received Quality (RSRQ) quantities are
included in the measurement report.
Maximum number of cells to include in the measurement report for the long 1..8
PM Initiated UE Measurements.
The interval for event-triggered periodical reporting for PM-Initiated UE ReportInter MS_120
Measurements. val MS_240
MS_480
MS_640
MS_1024
MS_5120
MS_10240
MIN_1
MIN_6
MIN_12
MIN_30
MIN_60
MS_2048
The Reference Signal Received Quality (RSRQ) threshold value for the long -195..-30
primary eventA1.
The hysteresis value for the primary eventA1 measurement. long 0..150
The time-to-trigger value for the primary eventA1 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The value component of the Relative Distinguished Name (RDN). string
The Reference Signal Received Power (RSRP) threshold value for the long -140..-44
secondary eventA1.
The Reference Signal Received Quality (RSRQ) threshold value for the long -195..-30
secondary eventA1.
The hysteresis value for the secondary eventA1 measurement. long 0..150
The time-to-trigger value for the secondary eventA1 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The value component of the Relative Distinguished Name (RDN). string
The Reference Signal Received Power (RSRP) threshold1 value for long -140..-44
eventA5.
The Reference Signal Received Power (RSRP) threshold2 value for long -140..-44
eventA5.
The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventA5.
The Reference Signal Received Quality (RSRQ) threshold2 value for long -195..-30
eventA5.
The Reference Signal Received Quality (RSRQ) in the threshold1 value long -195..-30
for eventB2.
Received Signal Code Power in the ThresholdUTRA, threshold2 value for long -120..-24
eventB2.
Ratio of energy per modulation bit to noise spectral density in the long -245..0
ThresholdUTRA, threshold2 value for eventB2.
Not applicable for UTRA TDD.
The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ
The quantity for threshold2 (neighbor UTRA cell) that is sent to the UE, TriggerQua RSCP
and is used by the UE together with threshold1 to trigger the eventB2. ntityUtra ECNO
The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventB2.
The Signal Quality in the ThresholdGERAN, threshold2 value for eventB2. long -110..-47
The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ
The Reference Signal Received Quality (RSRQ) threshold1 value for long -195..-30
eventB2.
The Signal Quality in the thresholdCDMA2000, threshold2 value for long -310..0
eventB2.
The hysteresis value for the eventB2 measurement on EUTRAN long 0..150
The time to trigger value for the eventB2 measurement. long 0,40,64,80,100,128,160
,256,320,480,512,640,1
024,1280,2560,5120
The quantity for threshold1 (serving EUTRAN cell) that is sent to the UE, TriggerQua RSRP
and is used together with threshold2 to trigger the eventB2. ntity RSRQ
This parameter together with a5Threshold2Rsrp specifies "The Reference long -10..10
Signal Received Power (RSRP) threshold2 value for eventA5." . The
equation for calculating the RSRP threshold2 value for ANR is
a5Threshold2Rsrp - a5Threshold2RsrpAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRP.
This parameter together with a5Threshold1Rsrq specifies "The Reference long -10..10
Signal Received Quality (RSRQ) threshold1 value for eventA5." . The
equation for calculating the RSRQ threshold1 value for ANR is
a5Threshold1Rsrq + a5Threshold1RsrqAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRQ.
This parameter together with a5Threshold2Rsrq specifies "The Reference long -10..10
Signal Received Quality (RSRQ) threshold2 value for eventA5." . The
equation for calculating the RSRQ threshold2 value for ANR is
a5Threshold2Rsrq -a5Threshold2RsrqAnrDelta . Only used if
triggerQuantityA5 onReportConfigA5 MO is set to RSRQ.
Only used if
triggerQuantityA1
Prim is set to
RSRP.
Only used if
triggerQuantityA1
Prim is set to
RSRQ.
Only used if
triggerQuantityA1
Sec is set to
RSRP.
Only used if
triggerQuantityA1
Sec is set to
RSRQ.
Only used if
triggerQuantityA5
is set to RSRP.
Only used if
triggerQuantityA5
is set to RSRP.
Only used if
triggerQuantityA5
is set to RSRQ.
Only used if
triggerQuantityA5
is set to RSRQ.
Only used if
triggerQuantityB2
is set to RSRP.
Only used if
triggerQuantityB2
is set to RSRQ.
Only used if
triggerQuantityB2
is set to RSRQ.
Only used if
triggerQuantityB2
is set to RSRP.
Only used if
triggerQuantityB2
is set to RSRQ.
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE
Not pure
dependence
towards
parameter on
ReportConficA5
Mo, but there
should be a
check that this
attribute and
corresponding
attribute on
ReportConfigA5
MO together
sends out a valid
number to the UE
Not pure
dependence
towards
parameter on
ReportConfigEUtr
aBestCell Mo, but
there should be a
check that this
attribute and
corresponding
attribute on
ReportConfigEUtr
aBestCell MO
together sends
out a valid
number to the UE