TECH SPEC Revision April 2010


General Information
Perth Concert Hall opened in September 2005. It has a capacity of 1186 seated and 1622 with standing (both these figures are
dependant on your contract with Horsecross). Perth Concert Hall is managed by Horsecross Arts who also manage Perth Theatre
which is less than 100m from the Concert Hall. The address above is the admin address for Horsecross Arts which remains in the
Theatre. For deliveries and access please see below. All mail should be addressed to the admin address.

Perth Concert Hall stage door address is;- The Admin address for Perth Concert Hall is ;-
Stage Door
Horsecross Arts Ltd
Perth Concert Hall
185 High Street
North Port
Perth
Perth
PH1 5UW
PH1 5HZ

Access to the stage and hall is good. The loading bay is located off stage left. It requires the vans/trucks to be parked 90
degrees to the loading door but there is a wide concrete platform to unload onto, which is under cover and just over 3m from the
stage. The loading bay pad is 0.6m (2’) high. Access door height is 2.4m (8’). This can be increased to 3.5m but it entails consider-
able cost.
Parking is extremely limited! 2 large vehicles (van/bus/truck) may be left at the loading bay by arrangement only. Unauthorised
vehicles parking round the loading bay /stage door will be fined £60 or get towed away and a fine of £135 levied by Perth & Kinross
Council regardless of who the vehicle belongs to. There is a multi-story car park very close to the hall and parking for larger vehicles
can be arranged 10mins walk from the hall. For full details see Page 3

1
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

General Info & index


Contacts Perth Concert Hall can be booked for a variety of events including performances, conferences and exhibitions. For initial
bookings please contact Michaela Ruff or Wendy Stenberg on 01738 477732 / 472707

Visiting companies with programmed events should contact Patrick Dalgety (Production & Technical Manager) or the “tech team” on
the numbers above.

Health & Safety Horsecross Arts prides itself on being a safe and pleasant place to work and perform.
To this end incoming companies are asked to observe the following;-
Submit full details, riders etc in good time (minimum one month)
Clearly advise of any Heath & Safety issues such as pyro’s or rigging/flying
Risk assessments must be submitted in advance with riders (minimum one month)
Proof of competence for the riggers and/or pyrotechnicians is mandatory
All rigging points are without exception put in by trained Horsecross staff
All visitors pyro’s or rigging/flying equipment will be checked by trained Horsecross staff
Maintain sound levels at concerts below 103dB A (this is measured and logged by Horsecross)
Failure to maintain defined sound levels will be referred to the relevant authorities
Ensure all visiting electrical equipment has a current PAT certificate
Where no certificate is available Horsecross reserve the right to test visiting equipment (which may be charged for) or
forbid its use on the premises
All materials on stage, be they fabric, timber, plastic or metal, must be fire retardant
Where applicable a certificate may be required to prove compliance with the relevant regulation
Ensure all staff, crew and performers have the relevant permissions to allow them to work in the European Community
Ensure all staff, crew and performers have the relevant training, competencies and skills and are physically fit and not under
the influence of either drinks or drugs which may render them liable to cause injury, damage or concern.
NB The above is not exhaustive. For full details refer to your contract with Horsecross

Catering On-site catering is provided in-house by Horsecross. Any company requiring to use facilities or their own
caterers must do this strictly by arrangement only. In certain circumstance it is possible to provide a prep room with
ovens and microwave ovens. See page 20 It is not possible under any circumstances to provide gas or electric
hobs or a space where these may be set-up. Due to ventilation/fire alarm issues this situation is not negotiable.

(if viewing as a pdf click on the page link to view)


Index
Page 3 Bus & Truck Parking Page 12 LIGHTING - DMX & dimmer patch

Page 4 Perth Concert Hall ground floor plan Page 13 LIGHTING - Standard Lighting Plan

Page 5 Gannochy Auditorium Page 14 LIGHTING - Equipment

Page 6 Extended stage & cabaret layouts Page 15 PA specs

Page 7 Flat floor and standing concert layouts Page 16 PA specs, continued

Page 8 Side elevation drawings Page 17 AV/projection equipment

Page 9 Rigging and flying plan Page 18 Other equipment

Page 10 LIGHTING - Power (inc sound power) & Bar Loading Page 19 Other equipment continued

Page 11 LIGHTING - info, non dims & FOH light patch Page 20 Dressing Rooms, laundry, catering etc

2
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Truck & Bus Parking !PLEASE READ THIS!


PARKING IS STRICTLY BY PRIOR ARRANGEMENT
We have a loading area on the North East quadrant which we must
manage very carefully; please read and follow these guidelines.
You must contact us!
Vehicles will not normally be granted permission to arrive during the night
or to park overnight at the Concert Hall. If this is granted access is on the plan
below
There is a 16A single phase c-form power supply accessed from a
combination lock box in the Louvre door of the low voltage room opposite the
“Fair Maids House”
The combination must be got in advance and time of arrival agreed upon!
The Concert Hall is in a noise sensitive area and care must be taken to
avoid disturbing the neighbourhood with music, engines, doors slamming or
raised voices. Any such incident will be reported to the police
When parking vehicles pay particular attention to members of the public using the right of way, make sure a banks man is
guiding the vehicle in.
PLEASE PAY PARTICULAR ATTENTION TO NOT OVERLAPPING THE DESIGNATED PUBLIC WALKWAY
DELINEATED BY THE PAVING SLABS AT OPPOSITE ANGLES TO THE PLAZA
Always ensure that the Public Right of Way is not impinged on. NEVER BLOCK ACCESS FOR FIRE TENDERS OR
ACCESS TO THE MUSEUM LOADING AREA , FINES WILL BE ISSUED REGARDLESS OF PARKING PERMIT
The paved area around the concert hall is the responsibility of the Council and is subject to the Roads Traffic Act.
Illegally parked vehicles will be subject to a fixed penalty of £60.
All vehicles using our loading area must display an official permit. These conditions apply equally on Sundays.
Permits removed or destroyed will be charged at £60.
Vehicular approach to the building will be from Charlotte Street to the North Port.

16A single phase c-form power


supply accessed with a combination
lock box in the Louvre

Cable must run over the fire


exit and under no
circumstances cross the
public walkway un-guarded

3
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Perth Concert Hall Ground Floor

4
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Gannochy Auditorium
Gannochy Auditorium Stage
20m (65’) wide @ front
15m (49’) wide @ rear
10m (32’) deep

Gannochy Auditorium seat allocation


104 stage extension All the formats shown are available with
401 stalls not Inc extension
261 raised stalls COMPLETE BLACK BOX for the stage
(Total stalls 766)
{When stalls removed standing room for 919 Including Black Harlequin “Cascade" stage/dance floor
Raised stalls remain 261}
420 Balcony (inc sides)
1186—seated
1622—with standing room
Please note actual seating numbers & allocations are dependant on layout and contract
5
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Extended stage & cabaret layouts

The above layouts can be achieved with format changes taking a minimum of 5 hours and 5 crew members.

It is essential that the format you require is arranged well in advance.

All the formats shown are available with COMPLETE BLACK BOX for the stage
Including Black Harlequin “Cascade" stage/dance floor
6
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Flat floor & standing concert layouts

The above layouts can be achieved with format changes taking a minimum of 5 hours and 5 crew members.

It is essential that the format you require is arranged well in advance.

All the formats shown are available with COMPLETE BLACK BOX for the stage
Including Black Harlequin “Cascade" stage/dance floor
7
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Side elevation drawings

Follow spots

Gannochy with stalls

Gannochy with Mosh Pit

Gannochy with flat floor

8
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Rigging & Flying NB no Fly tower

9
Any technical enquiries please contact
www.horsecross.co.uk info@horsecross.co.uk
Patrick Dalgety
Production & Technical Manager Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
DDI 01738 472702 pdalgety@horsecross.co.uk Or the tech team on 01738 477744
Fax 01738 624576

Bars
LIGHTING SWL
- Power and Overload
(inc sound power) & Bar Loading
pdalgety@horsecross.co.uk

Gannochy stage power


3 x 200A TPN (Three Phase & Neutral) (Powerlock) under stage SR, DSL + Broadcast Cabinet.
2 x 125A TPN(C-form) both side of the stage USL & USR
2 x 63A TPN(C-form) both side of the stage USL & USR
2 x 32A TPN(C-form) both side of the stage USL & USR
2 x 125A single phase (C-form) both side of the stage USL & USR (clean earth)
2 x 63A single phase (C-form) both side of the stage USL & USR (clean earth)
2 x 32A single phase (C-form) both side of the stage USL & USR (clean earth)
However! total achievable load limited to 400A (inc use of broadcast supply)

Bar weights and loading


Current Weight SWL Overload
Bar 2 130kg 750kg (max50Kg per m) 825kg
Bar 3 280kg 750kg (max50Kg per m) 825kg
Bar 4 200kg 750kg (max50Kg per m) 825kg
Bar 5 20kg 750kg (max50Kg per m) 825kg
Bar 6 250kg 750kg (max50Kg per m) 825kg

Please note we very rarely clear our lighting bars.


Incoming rigs need to be either underslung
OR
flown on their own truss & motor systems.
We do have 37m of truss & 6 x500Kg motors (by prior arrangement only!)

PCH stock Lamp weights


Mac 250 – 22.4kg Pacific 20 degree – 9.4kg

VL1000 – 32kg Pacific Zoom – 9.9kg

Source 4 Par – 3.6kg Source 4 750w 26 degree – 6.3kg

Parcan – 3.4kg Scroller – 3kg

Nova – 21.8kg IWB – 10kg

10
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

LIGHTING - info, non dims & FOH light patch


This Page and the following pages give information for the default Gannochy lighting.
A CAD file is available on request
Patch info for the rig is on page 11, this is essentially the LX plan as a table and laid out as per the plan.
Information regarding the house lights patch and non dims are given below.
A complete list on lanterns is given on Page 14.
PCH will generally not de-rig the bars as we have no facility to store the lanterns.
However, bar loading is such that it is generally not a problem to undersling bars for visiting rigs

NON DIMS
Non Dim Control Location Non Dim Control Location

1 G4 13 VL's B4 G1
2 Hazer G4 14 Scroll B4 G1
3 Scroll G3 G3 15 Novas B4 Stage Grid
4 Scroll G3 G3 16 Scroll B3 Stage Grid
5 Scroll G2 G2 17 Macs B3 Stage Grid
6 G2 18 DSL

7 Novas B6 Fstage Grid 19 DSL

8 VL's B6 Fstage Grid 20 DSR


9 SR Slip 21 DSR
10 SR Slip 22 USL
11 SL Slip 23 USR
12 SR Slip

G = Gantry B = Bar
HOUSE LIGHTS
Downlighters
151+152 Gantry 1
153+154 Gantry 2
160+161 Gantry 3
163+164 Gantry 4
173+174 Side
172+175 Under Balcony
Uplighters
169+170 Side
171 Back
LED Steps
176 Upstairs
177 Downstairs

Shortcut for all Houselight Circuits


151 THRU 154 , 160 THRU 164 , 169 THRU 177.
11
LX bar 1 Parcan S4 Par Parcan Parcan Parcan S4 Par Parcan S4 Par Parcan Parcan Parcan S4 Par S4 Par Parcan Parcan Parcan S4 Par Parcan S4 Par Parcan Parcan Parcan S4 Par Parcan

12
Dimmer 86 135 87 88 90 136 91 137 92 93 94 138 138 94 93 92 137 91 136 90 88 87 135 86

DMX 2

LX bar 3 S4 Par Parcan Mac250 S4 Par Parcan Parcan Parcan S4 Par Mac 250 S4 Par Mac250 S4 Par Nova S4 Par Mac250 S4 Par Mac250 S4 Par Parcan Parcan Parcan S4 Par Mac250 Parcan S4 Par

Dimmer 133 82 145 134 83 84 85 68 146 69 147 70 76 70 148 69 149 68 85 84 83 134 150 82 133

SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL

DMX 2 396 186 414 188 432 190 243 191 450 189 468 187 486

LX bar 4 S4 Par S4 Par Fresnel Fresnel S4 Par VL1000 S4 Par Fresnel Fresnel S4 Par S4 Par Fresnel Fresnel S4 Par VL1000 S4 Par Fresnel Fresnel S4 Par S4 Par

Dimmer 131 132 78 79 65 73 66 78 79 67 67 81 80 66 74 65 81 80 132 131

SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL

DMX 2 Amber Blue 180 342 182 Amber Blue 184 185 Blue Amber 183 369 181 Blue Amber

Sides Nova Fresnel Fresnel Fresnel Fresnel Nova

Dimmer 63 64 64 57 57 77

SCROLL SCROLL

DMX 2 234 252


Pros
Booms Parcan Parcan Parcan Parcan

Dimmer 96 95 71 72

SCROLL SCROLL

DMX 2 191 190 193 194

LX bar 6 S4 Par Nova VL1000 S4 Par Fresnel Fresnel S4 Par Fresnel Fresnel S4 Par VL1000 S4 Par Fresnel Fresnel S4 Par Fresnel Fresnel S4 Par VL1000 Nova S4 Par

Dimmer 27 34 36 27 30 31 27 30 31 28 37 28 32 33 29 32 33 29 38 35 29

SCROLL SCROLL

DMX 2 216 261 Amber Blue Amber Blue 288 Blue Amber Blue Amber 315 225

Gantry 2 Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom Pzoom

Dimmer 26 25 24 126 23 22 21 20 125 19 18 17

SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL


pdalgety@horsecross.co.uk

DMX 2 198 199 200 201 202 203

Slips S4 26 S4 26 S4 26 Pzoom Pzoom Pzoom Pzoom S4 26 S4 26 S4 26


Or

Dimmer 56 56 56 55 54 50 51 52 52 52

SCROLL SCROLL SCROLL SCROLL SCROLL

DMX 2 204 205 206 214 215 215 211 212 213
Key for
www.horsecross.co.uk

Gantry 3 80Volt Pzoom Pzoom 20D 80Volt Pzoom Pzoom 80Volt 20D 80Volt 20D 80Volt Pzoom Pzoom 80Volt 20D Pzoom Pzoom
table
Dimmer 41 16 15 124 42 14 13 43 123 44 123 45 10 9 46 124 8 7 Parcan Standard parcan
Source 4 Par, usually medium
SCROLL SCROLL SCROLL SCROLL S4 Par
lens
Selecon 1.2K
DMX 2 207 208 209 210 Fresnel Fresenal
Selecon 2K Fresenal+motorised Nova
LIGHTING - DMX & dimmer patch

Nova Yoke
Gantry 4 Mac250 Mac 250 Entour

20D 20D 20D Hazer 20D 20D 20D VL1000 VL000 shutter version with tungtan lamp
info@horsecross.co.uk

Selecon Pacific zoom 20-40


Dimmer 6 5 4 3 2 1 Pzoom lens
80 volt Selecon Pacific zoom 20
80volt -40 lens
the tech team on 01738 477744

Source 4 fixed
Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576

DMX 2 511 S4 profile 23


20D Selecon Pacific fixed lens 20
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

LIGHTING - Standard Lighting Plan

13
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

LIGHTING - Equipment
LOCATION DESCRIPTION OF ITEM NUMBER

Gannochy Auditorium ETC Congo lighting console

Strand SLD dimmers 100 x 2.5K, 24 X 5K, 23 non dim circuits (manual or DMX)

Vari*Lite 1000 Tungsten Shutter version 5

Selecon HP 2K Fresnels with Auto Yoke & Rainbow Scroller 5

Mac 250 Entour 6

ETC Source 4 Par 24

ETC Source 4 Par (c/w chromaQ Scroller) 12

Selecon 80v Pacific 1.2kw 12/28 Profile 6

Selecon Pacific 90 Profiles 600w 6

Selecon Pacific 12/28 800w profile 12

Selecon Pacific 12/28 800w profile (c/w chromaQ Scroller) 12

Selecon Pacific 20 600w profile 12

Par cans 36

Selecon 1.2K Fresnels with barndoors 24

Selecon Lui Cyc 1000w top floods 16

Selecon Lui 4 Way Linear groundrow 6

Pani HMV 1202-35 follow spot inc rectifier & stand (on gantry 4) 2
Total lanterns 150

Norrie Miller Studio Selecon Acclaim Axial 650w 24/44 profiles 4

Selecon Acclaim Fresnel 650w Fresnels 6

Selecon 1.2K Fresnels (current only to be replaced)


Ancillary equipment:
1.3m -3.5m Adjustable telescopic stand with 1.2m alloy T bar & fitting for stand 4

Doughty 50mm scaff pole base plates & 2m alloy scaff poles 5

Backlit wireless rigging remote. 1

Selecon Pacific Iris 6

Selecon Pacific Plastic Image Holder 6

B size Selecon Pacific Gobo Holder 24

M size Selecon Pacific Gobo Holder 12

M size Selecon Acclaim Gobo Holder 6

14
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

PA Specs
Main PA
2 9 speaker Meyer M1D self powered Array's
5 MM4 rear balcony delays
5 MM4 stage fills
2 MSW1P self powered subwoofer
System controlled by BSS Soundweb,
system capable of 99dB +/- 2dB across the auditorium

System may be reconfigured using additional equipment below & by re-angling the array's to achieve levels in
excess of 107dB +/-3dB (this by arrangement only)

Additional Speakers/Amplification
8 Meyer UPJ Powered Speakers (can be used as additional monitors)
2 Meyer 650-P – 2 x 18” Powered Sub Bass
12 EMacoustics M-12 Monitors
8 Mixes QSC PRX Amps, for above (fixed main auditorium only)
4 Stands for Meyer UPJ-1P Speakers

Main FOH console & rack


1 Yamaha PM5D Digital console (NB with manual mic-amps not recallable type) {2 X power supplies}
Source rack for above
1 EMO rack light
2 Sony Minidisc player/recorders
1 Sony CD player
1 Tascam D112 cassette player/recorders
1 Core 2 dual Intel MacMini with M-Audio Profire 26/26
(Inc Pro-Tools, Q,lab, iTunes, Soundstudio)
1 Klark Teknik 31 band graphic EQ
3 Shure U4D Dual Radio Mic Receivers (6 Channels)
1 Shure way RF amplifier splitter

Monitor Desk & Rack


1 Soundcraft MH4 48 mono chans
Rack 1 for above
5 BSS Opal FCS-966 (duel 31 band graphic)
2 MH4 power supplies
Rack 2 for above
1 EMO rack light
2 BSS Opal 944 Compressor/gate (2 comps + 2 gates each)
1 Sony CD player
1 Lexicon MPX1
1 Yamaha SPX2000

Portable system console(Norie Miller)


Yamaha 01V 96 (12mic chans)
In portable trolley for above
1 Denon DN 645T CD/Cassette Combo
1 Sony Minidisk/recorder
1 Shure U4D Dual Radio Mic Receivers (2 Channels)

15
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

PA Specs continued
Multicores
There are 82 mic lines and 40 audio-tie lines. These all terminate at the main audio patch bay in the control room, however
there are only 24 mic lines to SL & SR, for larger set-up separate multi's are used (see below)
1 70m 32 way Multicore last 8 chans with male & female on stage box
1 70m 16 way Multicore
The above is used for direct connection between stage, monitor & FOH desks
4 20m 8 way multi with 8 way female stage boxes (stage distribution)

Mics & DI's


10 Shure SM 58 Mics
2 Shure SM 58 Beta Mics
2 Sennheiser E935 vocal Mics
8 Shure SM 57 Mics
2 Shure SM 57 Beta Mics
10 AKG SE300B Powering/Output Module + CK 91 Capsules
6 AKG CK 98 Capsules
4 AKG CK 97 CVR Gooseneck Capsules
2 AKG VR 92 Extension Tubes
2 AKG 414 multipattern condenser mics
5 Sennheiser 604 E (drum mics)
4 Sennheiser 608 E (drum, brass, woodwind mics)
1 Beyer M88 bass drums & cabs
1 Shure Beta 52 bass drums & cabs
10 BSS AR 133 DI Boxes
7 Shure U1 Bodypack Radio Mic Transmitters
6 Sony ECM 77B Capsules (plugs for above)
2 Countryman boom/head mics for above
2 Shure U2 SM58 handheld Microphones
2 Shure U2 Beta87 handheld Radio Microphones

Mic Stands
K&M ULTRA-STABLE LOW BOOM STAND 25950
2
K&M OVERHEAD MICROPHONE STAND
4
K&M ST252 MULTI PURPOSE HIGH/LOW STAND
9
K&M SHORT MICROPHONE STAND WITH TELESCOPIC BOOM
7
K&M ONE HAND STAND ROUND BASE
2
4 K&M TELESCOPIC MICROPHONE STAND WITH BOOM
9 K&M WEIGHTED TABLE TOP MICROPHONE STAND

We regularly augment the system for various events by hiring in either additional Meyer
Cabinets (102dB A across the whole auditorium) or a separate D&B Q1 line array system
which is good for 116dB A, This must be arranged in advance!
Both systems from local suppliers
16
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

AV/projection equipment
Gannochy Panasonic PT-D10000E Projector Body
Auditorium 10000ANSI Lumens
Panasonic Long throw lens
Panasonic 0.8:1 Ultra Short Throw Lens
The above is usually flown over the balcony FOH when used . When used with rear projection the screen must be
5m from the back of the stage. Projector can be flown (by prior arrangement only)
Analog Way Octovue OVX831 Seamless Switcher
Denon DV100 DVD player
Edriol V-4 Video Mixer
Imac 20” Intel core 2computer , (running OS10 inc PowerPoint for mac, Keynote, Q-lab & Arkaos)
Dell Inspiron PC, (running XP service pack 3 and PowerPoint 2003)
Mac Mini intel core 2 duo(running OS10 and Windows 7 inc PowerPoint 2007 and Keynote)
PC (running XP service pack 3 and PowerPoint 2003)
All the above in Rack/trolley/console with preview monitors and switching

Lectern with electronic height adjustment and integral touch screen and keyboard linked back to AV Rack/trolley/console
Norrie Miller Sanyo PLC-XP100L Projector 6500 Ansi Lumen Data Projector
Studio Motorised Semi L/Throw Zoom Lens PLV-70)

4m x 3m Tci EL400 Channel-Fix Electric Screen (front projection only)


Kramer VP-724 Switcher Scaler
Yamaha 01V96 digital sound desk
Denon combined CD & cassette player
Sony Minidisk recorder/player
Shure U4D Dual Radio Mic Receiver (2 Channels)
Integral induction loop system (splitable with room)
Logic speaker system with integral delay and split room capability
All the above is controlled via Creston room controls including lighting, black-out blinds & Screen
Tay Room Hitachi CPX 430 XGA 2500 Ansi Lumen Projector
DVD Player
Denon PMA255UK Stereo Integrated Amplifier
Bose Freespace Loudspeaker System
Condenser Boundary Microphone (for recording minutes)
Denon DN780R Double Auto-Reverse Cassette Deck
Integral induction loop system

General Nec Plasma Sync 50XR4 - 50" True WXGA Screens 2


Equipment (generally in Tilt & Earn rooms but portable on wheeled stands with shelf for VHS/DVD player or laptop)

Kodak Carousel 35mm projector! 1

Overhead projector 1

Flip charts 5

various DVD players 3

VHS recorder/player 1

Portable induction loop system 1

Various Dell Laptops (running XP or Vista inc PowerPoint 2003/2007) 5

17
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Other equipment
ITEM DESCRIPTION QUANTITY
Surround bars for drapes 3

motorised LX bars 5

cablenet systems above stage to rig through 2

LX/rigging gantries 4

a system of I beams for rigging incoming equipment such as trusses (see rigging drawing)

Truss
3m Slick Lightbeam truss 9

2m Slick Lightbeam truss 3

1m Slick Lightbeam truss 3

0.5m Slick Lightbeam truss 2

Corner sections 4

Steel Base plates for the above 6

Verlinde SM5 504M1 500Kg hoist (four with double purchase pulleys to lift 1000Kg) 6

(PLEASE NOTE TRUSS & MOTORS MAY BE CHARGED FOR! USE BY PRIOR ARRANGEMENT ONLY)
Please Note: All rigging must be arranged in advance

Ampetronic phased loop array Induction loop

Sennheiser infra red transmitter system -6 panels

2 channel intercom system

body packs & headsets for above

CCTV camera distributed by UHF system round the building and composite video round technical 7
areas

all dressing rooms have show relay speakers and TVs for stage monitoring

Black Serge drapes

Legs (3m wide 8.5m drop) 6


drapes (9.5m wide 8.5m drop) 2
drapes (8m wide 8.5m drop) 2
drapes (3m wide 6.1m drop) 2
Borders to cover acoustic reflectors 1&2 2
Additional 1
White filled gauze Cyc (15m wide 8.5m drop)

18
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Other equipment continued


ITEM DESCRIPTION QUANTITY
Le Maitre "speed Fogger" Smoke machine (DMX controlled) 1

Le Maitre Haze machine (DMX controlled) 1

Black Harlequin cascade dance floor (stage & stage extension)

Steinway B Concert Grand Piano 1


Steinway D Concert Grand Piano 1
Steinway upright (Not performance standard) 1
Yamaha P80 Electronic piano (88 key, weighted) with stand 1

Rat Performer music stands with K&M lights 70


Conductor’s stand 1
Black cat soloist chairs 8
black upholstered chairs (suitable for orchestral use) 350
conductor’s podium 1
Fixed height lecterns 2
Electronically adjustable height Lectern (includes integral computer for presentations) 1
Steeldeck/Metrodeck Rostra system

8' x 4' steel deck 12


8' x 2' steel deck 12
6'x4' Metrodeck 14
6'x2' Metrodeck 4
4'x4' Metrodeck 2
4'x2' Metrodeck 2
Metrodeck specials (allow rostra system to fill entire upstage)
Prompt Corner/Stage Right The Gannochy Auditorium has prompt corner console stage right which includes;-
20” monitor connected to a fixed camera of the stage
7” Monitor connected to a control capable camera with infra-red capability
5” monitor connected to a fixed camera with view to stage left wing
6 way patchable cue light system
Mic and switch control with call to;- backstage, FOH, control room and the auditorium
Cans system with ability to listen/speak on either or both A & B circuits
FOH bell and bar buzzer
Mac Mini running windows XP with Full office 2007
Full House light and working lights control
Analog display clock and digital stopwatch/timer

19
www.horsecross.co.uk info@horsecross.co.uk

Patrick Dalgety Production & Technical Manager d: 01738 472702 f: 01738 624576
pdalgety@horsecross.co.uk Or the tech team on 01738 477744

Dressing Rooms, laundry, catering etc


Almond, Tummel & Dochard are three dedicated dressing rooms, each with clothes rail, en-suite toilet and
shower facilities, fridge and coffee making facilities. Situated on ground level with access to either side of the
Gannochy stage. One is often dedicated a touring production office
Room Capacity;- Almond-4/6 persons, Dochard-4/6 persons, Tummel-4/6 persons.
Tilt & Earn are two multi-purpose rooms which can be arranged for use as dressing rooms, conference
breakout rooms or small workshop spaces each with en-suite toilet and shower facilities.
Room Capacity;- Tilt-45 persons Max, Earn-40 persons Max.

Norie-Miller Studio - 120 persons Max


This space is primarily our secondary performance/conference facility. However, it can be split into two
rooms (60/50 persons max per room) or left as one complete room and used as a larger dressing room or
refectory. This must be arranged in advance as it is often booked independently of the main space

Dressing room equipment


13 x dressing room table mirrors with lights,
7 x Portable full length mirrors,
6 x portable clothes rails
1 x full size fridge
2 x Barco Boilers
This equipment is portable and can be relocated where needed

Laundry Facilities
PCH does not have a dedicated laundry room or wardrobe personnel.
Laundry facilities are located in the technical storage room, just off Gannochy stage left.
1 x washing machine 5kg load capacity

1 x tumble Dryer (Condenser) 7kg load capacity

2 x ironing boards

2 x steam irons
It is occasionally possible to make use of Perth Theatre’s laundry/wardrobe facilities,
this is strictly by arrangement only!

Braan Kitchen
Equipment below available by arrangement:-
1 x Blast Chiller, 1 x small microwave, 1 x water urn, 3 x prep tables, 2 x food washing sinks,
2 x dish washing sinks, 1 x Dish washer, 1 x food mixer, 1 x blender
It is not possible under any circumstances to provide gas or electric hobs or a space where these may be
set-up. Due to ventilation issues this situation is not negotiable.