Sie sind auf Seite 1von 1

GENERAL

This drawing is not be to scaled, use figured dimensions only


chimney All dimensions and heigts to be checked before any work
commences on site Any discrepences to be reported to the Architect immediately
All heights of plinths, depths of excavations and number of steps
to be finally checked by the contractor on site.
This drawing must be read in conjunction with the Structural Engineer's drawings.
The site must be treated for termites in accordance with Municipal By-Laws using
SHELLDRITE soil poisoner.
ROOF PITCH 22 Top of foundations to be a minimum of 600mm below natural ground level.
CONCRETE TILES ON 38X38 BATTENS ON TRUSSES BY SPECIALISTS ON Backfill to foundations.
114X38 WALL PLATE Top of concrete floor slab to a minimum of 200mm above finished ground level.
200X50 FASCIABOARD Concrete floor slab to be reinforced with S310 mesh wire. Black polythene
brick cladding damp proofing membrane on 50mm sand binding on well compacted hardcore.
RHINOBOARD CEILING ON 38X38 BRANDERING AT 400 CENTERS GUNDLE brickgrip emborsed damp proofing course under all brick walls,
75X100 G.I GUTTERS ON GUTTER DOWNPIPES AND DRIPSTONE UNDER windowsills and where floor levels change. Stormwater shall be removed
from dwelling, yard and site.
Electrical installations shall be a HEINEMANN earth leakage systems in
distribution board.
All building works to be carried out in accordance with municipal By-Laws

WEST ELEVATION 1:100 with the inspector approving every stage.


FOUNDATIONS
Drainage to engineer's specifications.
All foundations, foundation walls, structural concrete works and subsoil stormwater
TIMBER TRUSS BY SPECIALIST SOUTH ELEVATION 1:100 100mm diameter pvc swp at minimu
proposed sewer mai n
m gradient 1:60 to
footings under 230mm brickwalls.
230 x 460 concrete strip footings under 115mm brickwalls and 230x690 concrete strip
FLOORS
plasterboard ceiling plasterboard ceiling 75 x 19mm timber skirting with 9mm quadrant all round.
r.c lintel r.c lintel 40mm rough cement screed to all floors (tiles in kitchens and baths) rest with blocks.
WALLS

2750
All bricks to have GUNDLE dump proofing course on slabs and brickforce after every
BEDROOM 2 PASSAGE STUDY eleven brick courses.
chimney All bricks approved burnt clay commons/facings from Willdale or any other reputable
manufacturer (CAZ) approved.
chimney Windows to be built-in with GUNDLE damp proofing course under cill bricks.
dpc ffl ffl ffl dpc All paint works to comply with manufacturer's specifications and with
necessary under coats.
External finish rough cast plaster with three coats pva.
Internal finish steel trowel plaster, rhinoset skimming and 3 coats pva.

690x230 FOOTING 575x250 575x250 690x230 FOOTING ROOF


Asbestos cement trafford roof 0n
FOOTING FOOTING Gangnailed/sawn timber roof trusses, valleys and trimmings around chimneys
40mm CEMENT AND SCREED ON chimneys to be manufactured and erected by timber specialist.
SECTION A-A 1:100 100mm CONCRETE SLAB ON
150mm WELL COMPACTED HARDCORE FILL
WINDOWS AND DOORS
All windows and door frames standard pressed steel sections by
690X230mm CONCRETE FOOTING UNDER 230mm WALLS 6mm glazing/anodised alluminium sliding doors by specialist.
500X230mm CONCRETE FOOTING UNDER 115mm WALLS DRAINAGE
100mm glazed earthenware sewer drain with a minimum fall of 1:60

NORTH ELEVATION 1:100 Rodding eyes at all head of drain and at all change of direction
and at every 15m intervals.

EAST ELEVATION 1:100 Inspection eyes at junctions to have clearly marked covers on ground level.
Drains under buildings to be 100mm cast iron pipe encased in 150mm concrete
and waste pipes under floor slabs to sleeved.
All waste pipes must 65mm reseal traps and to be accessible over the entire
length for cleaning and repairing purposes.
20750 Gutter down pipes must discharge at a distance of not less than 1500mm
from an open gulley.
20000
230 2300 115 3500 115 2500 115 1000 115 1700 115 885 230 4335 230 2285 230 750 ELECTRICAL LEGEND
Distribution board 1500 above floor level.
100mm dia p.v.c pipe laid to fall 1:60 minimum gulley

230
Ceiling mounted light fitting.
gulley A
gulley ab ab

770
B.I.C Wall mounted light fitting.
ab
230

230
ab ab ab ab ab ab ab ab KITCHEN ab ab ab Waterproof ceiling mounted light fitting.
PASSAGE

tub (ceramic)
1549

wc Outside waterproof wall light.

4330
BEDROOM 1
BATH

( tiles)

(tiles) STUDY B.I.C 3620 3000


2840

2870
(tiles) Surface ceiling mounted downlighter.
wb
230 1081 115 850 115

shower Telephone Connection.


shower

abab
B.I.C beam over TV Connection.
512

230
ab

9000
B.I.C 50 Liter 1Kw Geyser connection.
PASSAGE
1100

(tiles)
8000

beam over to engineer's detail

100 Liter 2Kw Geyser Connection.


(porcelain tiles)
KITCHEN

ab B.I.C B.I.C LOUNGE 3640 150 Liter 3Kw Geyser Connection.


(carpet)

3870
15 Amp Plugpoint.
4425

MASTER BEDROOM BEDROOM 2 BEDROOM 3 4970


(carpet)
3600

(tiles) (tiles) Double 15 Amp Plugpoint.


3370

800 Light dimmer switch.


ab ab ab ab Ø300mm pier
230

ab Light switch 1240 above floor level.


beam over to
570

engineer's detail
800

ab ab ab ab ab ab Two-way light switch.


230

230

Bell switch
4450 3500 3730 4855 1235 Bell
230 115 A 115 230 230 230 415
Track with adjustable spot lights.
18920
Wall Spotlight.
19585 Oven connection.
Underfloor heating with thermostat.
FLOOR PLAN (155.77 Sqm) 1:100 Single fluorescent light fitting.

Double fluorescent light fitting.


Intercom unit.

SCALES
TITLE 1:100 1:200 DESIGNED

PROPOSED HOUSE ON ROYALE PROPERTIES REVISIONS


4433, 148TH STRT.

FOR ....................................................
WARREN PARK D
Date Descriptions Initials ADDRESS HARARE

DATE 2017-11-01

Das könnte Ihnen auch gefallen