Sie sind auf Seite 1von 1

No.

2/516i, 1st Floor, SNAA-Complex, Pollachi Mani Road,


Malumichampatti, Coimbatore-641050.Phone: 0422-2610110
Mail: nautsolutions@gmail.com.Web:nautsolutions.com

TEST REPORT

ML/B5000/1/16-
Report No / Date 17/Dt:24.12.2017
Your ref. / Date Letter/Dt: 24.12.2017
TOCR:B5000/16-17/
Our ref / Date Dt:27.12.2017
Nature of test Tensile Test, Bend Test
Test Method Customer Standard
Date Testing 26.02.2017
Sample Drawn By Customer
Test Sample Composite - B Qty:
Sample Description 1No
1.Tensile Test:

Test Parameters Observed Values

Ultimate Tensile Load (kN) 187.65

Ultimate Tensile Strength (MPa) 198.6


2.Bend Test:

Sample Length Width Thickness Mandrel Angle of


ID (mm) (mm) (mm) Dai (mm) Bend (Deg) Observation
Sample
1 195 19.50 36.00 24 1800 Broken
3.Hardness Number:

Sample ID Indenter Load Applied Diameter Brinell Hardness


Dia(mm) (KgF) (mm) Number
1 10 100 3.9 245.752

Verified by:

CONCLUDED

Authorized Signatory

NOTE: This report relates only to the particular sample submitted for test. Any correction in the
report will invalidate this report. Samples will be destroyed after 15 days from date of completion of
tests unless informed by the customer. Any complaints about this report should be communicated in
writing with in 7days form the date of receipt of report. This report cannot be reproduced except in
full. Sample description is given as described by the customer. Sampling is not carried out by the
laboratory.