Bevel gear box

Torque converter
Hydraulic pump compact + gear box

Shaft between motor


and bevel gear box

Front and rear


transmission shafts
FWD/RVS
6.5b limitor
Cold start Distributor
valve (26b)

14.5 b limitor

Suction filter

Oil Pump

converter
Super soft shift Valve

15 15
Soft Shift
14 14
13 13
12 12
11 11
10 10
Pressure (bar)

9 SUPER Soft Shift 9


8 8
7 7
6 6
5 5

1.5
4 4
3 3
2 15% GAIN 2
1 1
0 0
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
Time (s)
The right gear for
each application
Precaution to take before
taking the pressures

1- Temp must be 80°C when checking pressures.

2- Hand brake must be released. FWD/RVS lever must be in neutral

3- All pressure ports are 9/16" UNF. One pressure 0-20 bar gauge minimum.

4- For pressure adapters, hoses and pressure gauges, refer to catalogue: Réf. 547 037.

5- FWD/ RVS and 4th gear clutch pressures must not be inferior of 1 bar as of
indicated for pump pressure.

6- ATTENTION, MAKE SURE FWD/RVS LEVER IS IN NEUTRAL BEFORE


STARTING MEASURING PRESSURES
Cold start bypass
( 26 bar )

6,5 bar pressure limiter


Converter axle
+ transmission pump

14,5 bar limiter

Suction filter
FWD / RVS Electrovalve

FWD (dashboard light )


Pressure switch

Mechanical
gear lever

Oil filter

FWD shaft outlet


PUMP PRESSURE
14,5 ± 1 bar @ max rpm
(2500 rpm)

CONVERTER PRESSURE
6,5 ± 1,5 bar @ max rpm
(2500 rpm)
FWD CLUTCH PRESSURE
(pressure switch side)

14,5 ± 1,5 bar @ max rpm


(2500 rpm)

RVS CLUTCH PRESSURE

14,5 ± 1,5 bar à @ max rpm


(2500 rpm)
LUBRICATION PRESSURE

1,5 ± 1 bar @ max rpm


(2500 rpm)

CONVERTER STALL REVOLUTION : 1600 ± 50 rpm