BOTTOM ROW
TOP ROW
18 PE
N/A 18 17 B ProfiBus
N/A 17 16 A
16 15 NC
RS-485 B 15 14 C Relay #3
A 14 13 NO
GNO 13 12 NC
9.32” CTS 12 11 C Relay #2
RS-232 RTS 11 NO
10
RX 10 9 NC
TX 9 8 C Relay #1
N/A 8 7 NO
N/A 7 6 –
– 6 5 + 4-20mA DC Out FLOW
+ 5 4 –
– 4 3 + 4-20mA DC Out VELOCITY
8.875” + 3
7210 2 –
– 2 1 + 4-20mA DC Out LEVEL
10.815”
ACCURON® 7200
12.625” Battery (DC) In
7215 + 1
SUGGESTED SPECIFICATIONS: An ultrasonic microprocessor-based Cartridge Meter shall be installed at the location on the plans in accordance
with the manufactures recommendation. A field-ready___________(pipe size) stainless steel cartridge, containing a stainless steel trapezoidal flume/ultrasonic CARTRIDGE METERS
level sensor/transit-time velocity sensor combination shall be provided with each flowmeter. The IP66/Nema 4,4X flowmeter (or Chartmeter) shall be factory
programmed for the specific application and be provided with a datalogger integral to the electronics. The Cartridge Meter must be capable of field
validation prior to installation of permanent power. The unit shall be Model Accuron 7200 as manufactured by Eastech Flow Controls, Tulsa, OK or equal.
ORDERING GUIDE
CARTRIDGE METER NOMINAL PIPE PIPE PIPE SENSOR OPTIONS PROGRAM DATA
PIPE SIZE MATERIAL SCHED. CONST. CABLE RETRIEVAL
*For Cartridges larger than 15 inches please specify manhole entry size.
For Cartridge Meters larger than 24" or custom sizes, please contact factory.
Ordering Example: Accuron Cartridge Meter, 12" pipe size, PVC, Sched. 40, 30' cable, 3 relays, programming GPM: 7210-12" – P-S-W-A
4 5
ACCURON® 7200
HIGH FLOW MONITORING
Technology for FIELD READY Accuracy ±1-2% (act. rate) Turndown: 60:1 in-situ calibrations must be conducted in order to
develop a meaningful correlation.
Real World Applications INSTALLATION During periods of maximum flow (1/3 to full
pipe diameter),The Accuron measures flow Chordal measurement, utilizing a pair of
within its high operating range by utilizing highly accurate transit-time ultrasonic
The high performance design of the Accuron 7200 was THE CARTRIDGE METER IS A SINGLE FACTORY an extremely accurate area-velocity system sensors, provides detection of the chordal
based upon information and recommendations obtained INTEGRATED UNIT, DESIGNED FOR 30 MINUTE that combines an ultrasonic level sensor velocity along an entire path across the
through extensive open channel metering field tests FIELD INSTALLATION AND VALIDATION. with a pair of transit-time velocity sensors. fluid being measured. A predictable
conducted by the Environmental Protection Agency and correlation exists between chordal and
the U.S. Bureau of Reclamation. The challenge was to ULTRASONIC LEVEL SENSOR average velocity. Because the chordal velocity
PRE-SIZED
engineer an open channel flowmeter that was field ready, (Described in Low Flow Monitoring Section on page 4) more nearly represents the average area-velocity
Each field ready cartridge is pre-sized for it's intended
highly accurate and maintenance free. over the entire flow profile, this correlation permits
application. Gasketed and manufactured of 304 stainless NOTE: In the high flow range, it is possible that when the
steel, cartridges are installed within minutes. pipe becomes full, the level sensor will be submerged. accuracies within ± 1-2% in the high measurement
A special algorithm has been developed that will instanta- range of the Accuron 7200. Transit-time ultrasonic
PRE-ALIGNED neously convert the sensor reading from “in air”to “in water”, technology provides for highly efficient measurement
Installed accuracy is guaranteed through precision thereby enabling the Accuron to ascertain flow from zero of bi-directional flow throughout consistently changing
factory alignment and calibration of each component to 100% of pipe capacity. flow conditions. In addition, the effects of backwatering
encased within the cartridge. or stagnation are eliminated (EPA Report 600/2-76/243).
TRANSIT-TIME VELOCITY SENSORS VELOCITY SENSOR SPECIFICATIONS
PRE-PROGRAMMED The accurate measurement of average velocity is the major
Every Cartridge Meter is factory programmed in strict Environmental Rating Submersible Nema 4, 4X
technical problem encountered when attempting continuity
accordance to customer supplied operating specifications. Sensor Housing PVC
measurements. Ideally, the requirement is to accurately
Temperature -40° to 158°F (-40° to 70°C)
measure the flow velocity at each and every point within a
given cross-section of the fluid. A very limited method of Standard Cable Length 30ft.
velocity estimation utilizes a single point velocity measure- Warranty 18 months
ment and correlates this value with average velocity. This Accuracy ± 0.015 FPS
approximation is invalid in the case of non-uniform flow and Repeatability ± 0.25%
not sufficiently accurate over an entire regime of flow condi- Linearity ± 0.5%
LOW FLOW MONITORING tions. To provide a viable commercial result, a multitude of Turndown 60:1
4 5
ACCURON® 7200
THE CHARTMETER
Factory Programmed A SINGLE NEMA 4, 4X UNIT
INCORPORATING A CHART RECORDER,
Flowmeters FLOWMETER AND DATALOGGER
Accuracy .05% Full Scale Recording Time 24 Hour, 7 day, 31 day (user selectable)
Power Source 80/240 VAC, 50/60 Hz Response Time 4 sec. - 60 sec. (user selectable)
DATA LOGGING 12-28 VDC @ 150 mA Calibration Pen Arm
The Accuron has a built-in datalogger with eight distinct channels for logging Channels One Relays 3 SPDT (plug-in) 2.5 Amps
flow and totals.The storage capacity for a single channel at 5 minute intervals Recorder Display 112 x 16 Graphical Chart Replacement Alarm Flashing LED (Red)
is 113 days. Logger data may be visually accessed on the display of the meter Chart Rotation User Selectable Environmental protection Nema 4, 4X
in pre-programmed time intervals or retrieved through a laptop or optional Chart Range 0 - 100% of Full Scale Temperature Standard: -4° to 158°F (-20° to 70°C)
modem installed within the enclosure of the meter. Chart Size: 100 mm Diameter With Heater: -40° to 158°F (-40° to 70°C)
Daily Averages: Daily summary allows viewing of the previous eight
days. This includes times, dates, averages, minimums, maximums and totals.
Logger Graph: In addition, a bar graph may be visually displayed on the
Accuron. The graph will display the stored logger data in pre-programmed
time intervals. METER (Bi-directional) PREVIEW®
Data Retrieval: Logger data can be collected by using a laptop computer ENCLOSURE FIELD VALIDATION
or an optional modem installed within the Accuron enclosure. Standard IP66 / Nema 4, 4X polycarbonate enclosure A Preview® Validation Pac is provided with
Optional Explosionproof, Aluminum Enclosure every Accuron®. This allows for immediate field
Class I ,Grps. C & D, Class II, Grps. E, F, G. Div. 1 & 2 confirmation (up to 4 hours) of proper installa-
INFORMATION DISPLAY Accessories Heater and thermostat, Door Lock tion, programming, and operational integrity
The Accuron utilizes a 160 x 128 graphical LED backlit display.
TEMPERATURE prior to hook-up of permanent power.
The main screen can be programmed to display up to eight lines Standard -4° to 158°F (-20 to 70°C)
By simply connecting the Preview® Validation
of meter information such as flow, level, velocity, time, date and With Heater -40° to 158°F (-40 to 70°C)
Pac to the input terminals of the meter, correct
relay alarms.The order of display line information is programmed OUTPUTS sensor wiring, installation, programming and
to user preference. The backlit display may be programmed to 3) 4-20 mA Analog isolated into 800 ohms max, monitored
be ON or OFF, or to remain OFF during a selected time interval. data display can be confirmed and datalogged.
(Flow, Level,Velocity) to detect open circuits. RFI and gas
Display contrast is fully adjustable. discharge surge protection and two fuses.
Diagnostic information is retrieved via a menu-driven self-test Relay Alarms 3 SPDT (plug-in) 2.5 Amps
program capable of isolating fault parameters such as: loss of RS-232 Serial Port 1200-38400 Baud, Modbus RTU
signal, 4-20 mA loop failure, logger memory full, communica- RS-485 Serial Port Optically isolated, Modbus RTU
tions error, sensor fault and open transmitter cable connection.
Network Protocols Modbus, Profibus or DeviceNet
DC Power Out 12 VDC. 100mA maximum
DATA ACQUISITION DISPLAY
Current Output: Three 4-20 mA. Isolated, 800 ohms maximum. Backlit LCD 160 x 128 pixel graphical LED
Relay Outputs: Three SPDT relays available for alarm conditions. POWER
Serial Outputs: RS-232/485: With Modbus protocol. Wattage 30
Data Logging: Eight distinct channels are available. Voltage 80/240 VAC, 50/60 Hz / 12-28VDC @ 150 mA.
Communication Protocols: Modbus®, Profibus® or DeviceNet® DATA LOGGING
Non-volatile flash memory, storage of up to 32768 records.
6 7
ACCURON® 7200
THE CHARTMETER
Factory Programmed A SINGLE NEMA 4, 4X UNIT
INCORPORATING A CHART RECORDER,
Flowmeters FLOWMETER AND DATALOGGER
Accuracy .05% Full Scale Recording Time 24 Hour, 7 day, 31 day (user selectable)
Power Source 80/240 VAC, 50/60 Hz Response Time 4 sec. - 60 sec. (user selectable)
DATA LOGGING 12-28 VDC @ 150 mA Calibration Pen Arm
The Accuron has a built-in datalogger with eight distinct channels for logging Channels One Relays 3 SPDT (plug-in) 2.5 Amps
flow and totals.The storage capacity for a single channel at 5 minute intervals Recorder Display 112 x 16 Graphical Chart Replacement Alarm Flashing LED (Red)
is 113 days. Logger data may be visually accessed on the display of the meter Chart Rotation User Selectable Environmental protection Nema 4, 4X
in pre-programmed time intervals or retrieved through a laptop or optional Chart Range 0 - 100% of Full Scale Temperature Standard: -4° to 158°F (-20° to 70°C)
modem installed within the enclosure of the meter. Chart Size: 100 mm Diameter With Heater: -40° to 158°F (-40° to 70°C)
Daily Averages: Daily summary allows viewing of the previous eight
days. This includes times, dates, averages, minimums, maximums and totals.
Logger Graph: In addition, a bar graph may be visually displayed on the
Accuron. The graph will display the stored logger data in pre-programmed
time intervals. METER (Bi-directional) PREVIEW®
Data Retrieval: Logger data can be collected by using a laptop computer ENCLOSURE FIELD VALIDATION
or an optional modem installed within the Accuron enclosure. Standard IP66 / Nema 4, 4X polycarbonate enclosure A Preview® Validation Pac is provided with
Optional Explosionproof, Aluminum Enclosure every Accuron®. This allows for immediate field
Class I ,Grps. C & D, Class II, Grps. E, F, G. Div. 1 & 2 confirmation (up to 4 hours) of proper installa-
INFORMATION DISPLAY Accessories Heater and thermostat, Door Lock tion, programming, and operational integrity
The Accuron utilizes a 160 x 128 graphical LED backlit display.
TEMPERATURE prior to hook-up of permanent power.
The main screen can be programmed to display up to eight lines Standard -4° to 158°F (-20 to 70°C)
By simply connecting the Preview® Validation
of meter information such as flow, level, velocity, time, date and With Heater -40° to 158°F (-40 to 70°C)
Pac to the input terminals of the meter, correct
relay alarms.The order of display line information is programmed OUTPUTS sensor wiring, installation, programming and
to user preference. The backlit display may be programmed to 3) 4-20 mA Analog isolated into 800 ohms max, monitored
be ON or OFF, or to remain OFF during a selected time interval. data display can be confirmed and datalogged.
(Flow, Level,Velocity) to detect open circuits. RFI and gas
Display contrast is fully adjustable. discharge surge protection and two fuses.
Diagnostic information is retrieved via a menu-driven self-test Relay Alarms 3 SPDT (plug-in) 2.5 Amps
program capable of isolating fault parameters such as: loss of RS-232 Serial Port 1200-38400 Baud, Modbus RTU
signal, 4-20 mA loop failure, logger memory full, communica- RS-485 Serial Port Optically isolated, Modbus RTU
tions error, sensor fault and open transmitter cable connection.
Network Protocols Modbus, Profibus or DeviceNet
DC Power Out 12 VDC. 100mA maximum
DATA ACQUISITION DISPLAY
Current Output: Three 4-20 mA. Isolated, 800 ohms maximum. Backlit LCD 160 x 128 pixel graphical LED
Relay Outputs: Three SPDT relays available for alarm conditions. POWER
Serial Outputs: RS-232/485: With Modbus protocol. Wattage 30
Data Logging: Eight distinct channels are available. Voltage 80/240 VAC, 50/60 Hz / 12-28VDC @ 150 mA.
Communication Protocols: Modbus®, Profibus® or DeviceNet® DATA LOGGING
Non-volatile flash memory, storage of up to 32768 records.
6 7
DIMENSIONS WIRING SCHEMATIC DUAL RANGE
BOTTOM ROW
TOP ROW
18 PE
N/A 18 17 B ProfiBus
N/A 17 16 A
16 15 NC
RS-485 B 15 14 C Relay #3
A 14 13 NO
GNO 13 12 NC
9.32” CTS 12 11 C Relay #2
RS-232 RTS 11 NO
10
RX 10 9 NC
TX 9 8 C Relay #1
N/A 8 7 NO
N/A 7 6 –
– 6 5 + 4-20mA DC Out FLOW
+ 5 4 –
– 4 3 + 4-20mA DC Out VELOCITY
8.875” + 3
7210 2 –
– 2 1 + 4-20mA DC Out LEVEL
10.815”
ACCURON® 7200
12.625” Battery (DC) In
7215 + 1
SUGGESTED SPECIFICATIONS: An ultrasonic microprocessor-based Cartridge Meter shall be installed at the location on the plans in accordance
with the manufactures recommendation. A field-ready___________(pipe size) stainless steel cartridge, containing a stainless steel trapezoidal flume/ultrasonic CARTRIDGE METERS
level sensor/transit-time velocity sensor combination shall be provided with each flowmeter. The IP66/Nema 4,4X flowmeter (or Chartmeter) shall be factory
programmed for the specific application and be provided with a datalogger integral to the electronics. The Cartridge Meter must be capable of field
validation prior to installation of permanent power. The unit shall be Model Accuron 7200 as manufactured by Eastech Flow Controls, Tulsa, OK or equal.
ORDERING GUIDE
CARTRIDGE METER NOMINAL PIPE PIPE PIPE SENSOR OPTIONS PROGRAM DATA
PIPE SIZE MATERIAL SCHED. CONST. CABLE RETRIEVAL
*For Cartridges larger than 15 inches please specify manhole entry size.
For Cartridge Meters larger than 24" or custom sizes, please contact factory.
Ordering Example: Accuron Cartridge Meter, 12" pipe size, PVC, Sched. 40, 30' cable, 3 relays, programming GPM: 7210-12" – P-S-W-A