Sie sind auf Seite 1von 6

GRUNDFOS

FIRE PROTECTION SYSTEMS


GRUNDFOS
FIRE protection SYSTEMS
FULL RANGE
Grundfos is a full-line fire system supplier that fully
complies with a globally recognised list of approvals
and listings. We design, manufacture and service our

EXPERTISE
fire pump systems all over the world, and our products
are renowned for their quality, high performance and
reliability.

FIRE PUMPS FOR EVERY STANDARD


Grundfos application areas:
• Industrial plants
• Public water supply
• District cooling / heating plants
• Air-con / heating systems
• Fire protection
• Cooling systems
• Irrigation

96982928 0609

GRUNDFOS Management A/S


Poul Due Jensens Vej 7
DK-8850 Bjerringbro
Tel: +45 87 50 14 00
www.grundfos.com
FIRE PROTECTION SYSTEMS
INTRODUCTION

Grundfos fire pumps supply WE haVE DOUBLED


high-class safety to clients UP THE KNOW-HOW
around the world. Our Two experts for the price of one
expertise spans the globe and Grundfos is a proud company with an extensive
history of pump manufacturing and innovation. In

covers all UL-FM approved fire


order to further develop our expertise within fire
systems, we’ve recently acquired another proud
company with a famous 100-year history in the fire

systems pump industry – the American pump icon, Peerless.

Peerless has extensive experience with fire pumps of


the NFPA 20 standard and FM-UL approved systems.
With Grundfos as your fire system supplier, you It is also a company that shares the Grundfos values
can rest assured that your system lives up to the of superior quality products, strong customer focus,
highest international standards of quality. We and an in-depth understanding of the realities of fire
have products that comply with your every need protection.
and the following approvals:
• PSB
• VNIIPO
• CCCF Global presence in Wahlstedt, Germany, is at the heart of fire
• APSAD Grundfos secures efficient and direct deliveries to competence in Europe. Here we manufacture and test
• CEPREVEN the construction sites of all our European customers, FM and VdS approved systems. Comprehensive on-site
• VdS and with a sales and service centre in every market, design, testing and a full range of customer training
• UNI Grundfos is never far away. Our competence centre facilities are also provided.
• LPCB
• EN 12845
• CNBOP SERVICE AND EXPERTISE
We cover the world
• FM
• UL
• NFPA 20

Local assembly sites


& competence centres

53 sales companies
FIRE PROTECTION SYSTEMS
versatility

RELIABILITY ACROSS Supreme performance –


THE FULL RANGE UL-listed and FM-approved
Full-line supplier Secondly, approved systems provide maximum Grundfos provides top performance electric and diesel which is listed by UL (Underwriters Laboratories) and
Grundfos produces fire pump systems for: reliability and superior quality. Thirdly, using approved systems with all the relevant listings and approvals. approved by FM (Factory Mutual). The systems can be
• Fire hose reels and listed fire pumps typically reduces insurance Our European regional competence centres for fire supplied as either electric or diesel systems. Below,
• Fire hydrants rates significantly. pumps produce systems manufactured to most local you can see the standard performance range of our
• Fire sprinklers approvals including the NFPA pamphlet 20 code, electric and diesel pumps.
When third party approval is not required for a fire
We design and build systems ranging from simple pump installation, Grundfos can supply non-listed fire
pump-driver systems on a base frame to highly systems that comply with specific fire standards. Performance range of electric fire pumps 50 Hz Performance range of diesel fire pumps
engineered and fully enclosed, packaged systems.
H p H p
We are proud to have the widest range of fire pump [m] [psi] [m] [psi]

approvals and listings worldwide, and our expertise 200 200

enables us to engineer, produce, stock, distribute and 100 150 100 150

service our products all over the world. 80 120 80 120


70 100 70 100
60 60
80 80
50 50
There are three main reasons for choosing fire pumps 60 60
40 40
that are approved and certified by accredited third 50 50
30 30
40 40
party authorities. Firstly, based on the massive
30 30
experience embodied in leading fire protection, 20 20

regulations and codes, approved systems reduce the 20 20

risk of damage to life and property in the case of fire. 250 400 600 1000 2000 4000 6000 250 400 600 1000 2000 4000 6000
Q [US GP M]
Q [US GP M]

60 80 100 200 300 400 600 800 Q [m≥/h] 60 80 100 200 300 400 600 800 Q [m≥/h]

Electric fire pump units are built Diesel fire pump units are built
in two different configurations: in three different configurations:
Compact: Fire pump and electric motor – complete Compact: Complete diesel fire pump unit including
system mounted on one base including wiring and fire pump, diesel engine, fuel tank, batteries and
control panel. control panel on one base frame.
Note: this configuration is not available for all fire
Flex: Fire pump and electric motor mounted on base pump sizes, since the fuel tank is too big for the
and control panel separately supplied for wall or floor largest diesel engines.
mounting.
Flex: Same as compact, but with separately mounted
fuel tank and control panel. Wall or floor mounted.

Flex B: Same as Flex, but with the control panel


mounted on a base frame.
FIRE PROTECTION SYSTEMS
The details

Electric Fire pump Electric fire pump controller


• FM approved controllers as standard
Diesel Fire pump Diesel fire pump controller

– FM approved – FM approved
with CE-mark designed to
comply with NFPA 70 • FM approved controllers with
• Standard NEMA 2 enclosure – CE-mark as standard
corresponds to IP 42
Fuel tank • Standard NEMA 3R enclosure,
• Micro-processor based logic and • Designed and sized corresponding to IP 24
pressure/event recorder (printer) according to NFPA 20 • Thru-the-door thermal printer for
as standard • Single wall as standard 7-day pressure / 15 day event recorder
Optional Optional date retrieval
Diesel motor • Single wall with • Simple start-up and maintenance
• UL listings and CSA approval
Starting options : Star delta, • FM approved John Deere motor with industrial silencer and collection basin procedures
flexible exhaust • Double wall tank Optional
Electric motor part winding, soft start,
auto transformer • Power safety factor is per NFPA 20 • UL listing • UL listing
• Power safety factor and high reliability • To ensure optimal performance, each diesel fire pump set is
• USB communication port
• Grundfos IEC motor accepted by FM tested at our test bed at rated flow after final pump assembly
(7 days event and 15 days pressure)
• High reliability Grundfos IEC motor • Engine is cooled by a heat exchanger to ensure proper operation
accepted by FM Optional
Optional • UL listing
• UL Listed motor for Fire • Residential silencer
• Other engine brands

Coupling
• Flexible pin coupling design from Flender, Coupling
accepted by FM
• Flexible pin coupling design from
• Maximum operational reliability (fail-safe)
Centraflex, accepted by FM
• Prevents shaft stress by compensating for
• Maintenance free
shaft mis-alignment
• Allows shaft movement in axial,
radial and angular directions
• Maximum operational reliability
(fail-safe)
Optional
• UL listed couplings

Battery set
• Two battery sets (lead acid)
24 volt provide redundant
power supply and ensure full
Base frame reliability
• Welded frame with a rigid design that • Sized according to NFPA 20
ensures easy alignment on-site for driver, Optional
fire pump and controller • Nickel cadmium batteries
• Standard non-drip frame (open)
• Lifting points for easy transportation
• Painted in red RAL 3000 paint
Base frame
• Welded frame with a rigid design that
ensures easy alignment on-site for driver,
Fire pump Fire pump fire pump and controller
• FM approved to NFPA 20 as standard • FM approved as standard • Drip rim base (closed) as standard
• Factory performance and hydrostatic tested • Factory performance and hydrostatic tested • Lifting points for easy transportation
• Designed for highest efficiency, easy maintenance and service • Designed for highest efficiency, easy maintenance and service • Painted in red RAL 3000 paint
• Quick delivery pump programme for end-suction and split-case models • Quick delivery pump programme in end-suction and split-case
• Available as in-line and vertical turbine pumps models
• With ANSI flanges (End Suction pumps with DIN flanges as standard) Optional
Optional • UL listing FM authorised
• UL listing for fire • In-line and vertical turbine pumps • The FM logo ensures that the diesel fire pump
• Adapters for DIN flanges • Adapters for ANSI – or DIN flanges is assembled with FM approved components
and at an OEM and FM approved and authorised
manufacturing facility
FIRE PROTECTION SYSTEMS
Customised solutions

Beyond standard products Case references


At Grundfos, we have always considered a complex Modularised systems
project a great challenge. That is why we offer European projects with Grundfos FM fire systems
Grundfos designs and builds customised systems
completely customised solutions that match the that meet your specific needs. We mount the fire
requirements of even the most complicated tasks. pump, driver, controller and piping with complete Project Name Location Country Application Equipment

interconnected wiring on a common base or a Hotel Beach Vilamoura Portugal Tourist resort Two electric end-suction
Expanded quick delivery programme modularised base frame for final assembly on IKEA Matosinhos Portugal Warehouse Duplex
Our quick delivery programme contains more than the GDF Montoir France Power plant Electric vertical turbine
location.
electrically or diesel-driven End Suction and Horizontal SATO Athens Greece Industrial plant Duplex
Split Case pumps. We also supply: Packaged / containerised systems Hager Athens Greece Warehouse Duplex
• In-Line fire pumps With Grundfos’ enclosed systems, your installation- Jumbo Limassol Cyprus Warehouse Duplex
• Vertical Turbine pumps (for wet pit applications, to-operation time is minimal. Our enclosed systems ThyssenKrupp Terni Italy Industrial plant Diesel split case
or applications where positive inlet pressure is not are typically built as an integrated pump and control Pinewood Campus Wokingham England Office block Diesel end-suction
available) centre with: Kohler Mira Cheltenham England Factory Diesel split case
• Diesel engine Henkel Istanbul Turkey Industrial plant Diesel split case
• All the required controllers
• In-house piping
• Fittings
• Interconnected wiring
Belchatow Power, Lodz
When Alstom Power built its new power plant in
• A complete installation that meets the
Belchatow near Lodz in Poland, it chose Grundfos to
requirements of UL, FM, NFPA 13 and NFPA 20
deliver the hydrant and sprinkler installations for the
fire fighting system, because we offered a complete
solution – with pumps, controls and accessories built
into a common base plate.

Pumps installed:
• 2 x FK200-150/320-JU6H-UF30 pump set with
fuel tank, controller and engine all mounted
together
• 1 x CR3-15 A-A-A-E-HQQE 3x230/400 50HZ
• 1 x UL/FM LISTED JOCKEY PUMP STARTER

A back-up plan: the Grundfos


duplex system has both a
electric engine and an diesel
engine for extra safety.
FIRE PROTECTION SYSTEMS
CUSTOMER SUPPORT

FULL-LINE includes
THE SUPPORT AS WELL
Grundfos service is not limited to delivering a product. design phase of a project. The programme features
We are there all the way from design, installation, the following benefits:
maintenance and training. • Enables sales offices to quickly and accurately select
the adequate pump systems for your needs
We are particularly proud of our RAPID system. • Generates quotations with all the necessary
RAPID is a comprehensive electronic product selection commercial and technical information
programme that provides unique assistance in the • Forwards the full design submittal information to
our business partners

EXPERTISE AT THE HEART OF EUROPE


With RAPID, your project is one step ahead from the
beginning.

Grundfos Wahlstedt – The Wahlstedt centre features:


• Production, assembly, and test facilities
the European competence centre
approved by FM and VdS
The Grundfos fire competence centre located
• Quality accreditations such as ISO 9001,
in the northern part of Germany, sets the scene
14001, 18001, and EMAS
for a collection of activities that all promote the
• Witness tests where customers can supervise
technology, production and knowledge behind
the testing of their products
great fire protection systems.
• Stock facilities for pumps, motors, engine units,
and control panels
• Customer support facilities for applications,
system design, logistics, sales and service

Das könnte Ihnen auch gefallen