Instrument transformers for


indoor applications
Product overview

Instrument transformers
for indoor applications
Product overview

2 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W
2


Contents

03 Introduction

Current transformers
Supporting type
06 TPU, TPE
07 KOFA, IHBF
10 Dummy
Bus type
08 KOKS 12, 17.5
Bar primary bushing type
08 TTR
Bushing type
09 BB, BBO
Special types
09 BP - 15
10 KOKS 24

Voltage transformers
Single pole
11 TJC, TJE
12 TJP
13 KGUGI
Double pole
12 TDC
13 KGUG
Accessories
14 VT Guard PRO, PRO D
3 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W


ABB - a global technology leader
Foundation of the factory in Brno dates back to 1887. During its more
than 120-year-history it gained deep knowledge and a strong position
in the electro-technical field and became known all over the world. The
production of transformers in the factory in Brno started in 1912. First
transformers were oil insulated, production of transformers with
epoxy insulation started already in 1952.

The production facility in Brno joined the ABB Products gained their worldwide reputation in
Group in 1993; since that time the production has power distribution applications thanks to more
been continuously developing and nowadays is than 2,000,000 installed units.
one of the world’s largest Instrument Transform-
ers and Sensors production plant with an annual As a result of continuous research in ABB’s Brno
production of more than 150,000 units applica- development center are products with latest de-
tions worldwide. sign. As such, the center is committed to the pur-
suit for new opportunities, new technologies and
Thanks to the automation and investments, ABB to improve processes. One of the areas of the
in Brno became the technology leader using the fully equipped development center is an indepen-
most modern production systems and concepts, dent testing laboratory used for type testing.
such as automated production lines and testing.
INTRODUCTION 4

Additionally, the factory has its own testing labo- Our conventional portfolio includes more than
ratory with the latest equipment for precise 100 types of products for indoor applications in
measuring of all units, which are routinely tested medium voltage systems for voltages from
according to required standards like IEC, CSN, 0.72 kV up to 40.5 kV.
GOST, BS, AS, ANSI. This laboratory is also certi-
fied by the following national bodies allowing The main line of ABB instrument transformers is
ABB to issue metrology verification certificates designed in accordance with DIN 42600, which
when requested by customers: offers compatibility with a wide portfolio of ap-
plications. The portfolio reflects the market
• PTB (Germany) trends and is continuously developing according
• Electro Suisse (Switzerland) to the customers’ requirements.
• BEV (Austria)
• Energocert (Russia) ABB in Brno has been certified in the following
• Urad za meroslovje (Slovenia) quality management systems ensuring that prod-
• SMU (Slovakia) ucts that come out of the factory are of the high-
est quality:
ABB’s Instrument Transformers and Sensors fac-
tory in Brno offers a wide range of Conventional • ISO 9001
Instrument Transformers as well as Electronic In- • ISO 14001
strument Transformers (Sensors). • OHSAS 18001
5 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W


Current transformers

— —
TPU TPE
A current transformer so arranged that it acts as a support A current transformer so arranged that it acts as a support
for the conductor in the primary circuit. TPU current trans- for the conductor in the primary circuit. TPE current trans-
formers are suitable for the current air insulated switchgear formers have lower ratings suitable for secondary distribu-
portfolio, OEM (Original Equipment Manufacturer) partners, tion system, OEM.
utilities and many others.
Characteristic
Characteristic • Supporting type
• Supporting type • For measuring and protection with one or two secondaries
• For measuring an protection with up to 6 secondary wind- only
ings (12 clamps) • Secondary reconnectable versions
• Secondary or primary reconnectable • Capacitive voltage divider in CT body for voltage indicator
• Capacitive voltage divider in current transformer (CT) available
body for voltage indication available • Most standards available (IEC AS, BS, ANSI, VDE, CSN, oth-
• Most electrical standards available (IEC, GOST, AS, BS, ers on request)
ANSI, VDE, CSN, others on request) • Optional transparent secondary terminal
• DIN dimensions according to 42600 part 8
• Transparent secondary terminal cover as an option Ratings
• Suitable for tariff metering • Highest voltage for equipment: 3.6 - 24 (25) kV
• Sealable secondary terminal • Primary current: 30 - 1 250 A
• Rated short - time thermal current: 25 kA /1 s
Ratings • Secondary current: 1 or 5 A
• Highest voltage for equipment: 3.6 - 40.5 kV • Frequency: 50 or 60 Hz
• Primary current: 10 - 3 200 A
• Rated short - time thermal current: up to 100 kA /1 s
• Secondary current: 1 or 5 A
• Frequency: 50 or 60 Hz
CURRENT TR ANSFORMERS 6

— —
KOFA IHBF
A current transformer so arranged that it acts as a support A current transformer so arranged that it acts as a support
for the conductor in the primary circuit. KOFA current trans- for the conductor in the primary circuit. IHBF current trans-
formers are suitable for the former ABB air insulated switch- formers are suitable for the former ABB air insulated switch-
gear like MH type , etc., OEM. gear like Safesix, etc., OEM.

Characteristic Characteristic
• Supporting type • Supporting type
• For measuring and protection with up to 3 secondary • For measuring and protection with up to 2 primary recon-
windings nectable versions
• Primary reconnectable versions available • Secondary or primary reconnectable versions
• Most standards available (IEC, ANSI, CAN, BS,..) • Most standards available (IEC, ANSI, CAN, BS,..)
• Sealable secondary terminal • Plug-in or clamp type secondary terminal available

Ratings Ratings
• Highest voltage for equipment: 3.6 - 24 kV • Highest voltage for equipment: 3.6 - 24 kV
• Primary current: 10 - 2 500 A • Primary current: 10 - 2 000 A
• Rated short - time thermal current: 54 kA /1 s • Rated short - time thermal current: 50 kA /1 s
• Secondary current: 1 or 5 A • Secondary current: 1 or 5 A
• Frequency: 50 or 60 Hz • Frequency: 50 or 60 Hz
7 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W

— —
KOKS 12, 17.5 TTR
A current transformer without primary conductor, but with A current transformer with bar primary conductor so con-
primary insulation which can be fitted directly over a con- structed that it can be used as a bushing. TTR current trans-
ductor or busbar. formers are suitable as a bushing between two AIS compart-
ments, different switchboards, OEM.
Characteristic
• Bus type Characteristic
• For measuring an protection with up to 6 secondary wind- • Bar primary bushing type
ings • For measuring and protection with up to 2 secondary
• Secondary reconnectable windings
• Most electrical standards available (IEC, GOST, AS, BS, • Secondary reconnectable versions available
ANSI, VDE, CSN, others on request)
• Suitable for tariff metering Ratings
• Highest voltage for equipment: 3.6 - 24 (25) kV
Ratings • Primary current: 100 - 2 500 A
• Highest voltage for equipment: 3.6 - 17.5 kV • Rated short - time thermal current: 100 kA /1 s
• Primary current: 500 - 4 000 A • Secondary current: 1 or 5 A
• Rated short - time thermal current: 90 kA /1 s • Frequency: 50 or 60 Hz
• Secondary current: 1 or 5 A
• Frequency: 50 or 60 Hz
CURRENT TR ANSFORMERS 8

— —
BB, BBO BP - 15
A current transformer without primary conductor but with A current transformer suitable for outlets of generator, etc.
primary insulation of its own which can be used as a bush-
ing. Characteristic
• Special type
Characteristic • Current transformer in special design for generator out-
• Bushing type lets
• For measuring and protection with up to 3 secondary • up to 3 secondary windings
windings • Most electrical standards available (IEC, CSN)
• Secondary reconnectable versions
• Most electrical standards available (IEC, CSN) Ratings
• Highest voltage for equipment: 3.6 - 17.5 kV
Ratings • Primary current: 2 000 - 10 000 A
• Highest voltage for equipment: 3.6 - 24 (25) kV • Rated short - time thermal current: 80 kA /1 s
• Primary current: 600 - 5 000 A • Secondary current: 1 or 5 A
• Rated short - time thermal current: 80 kA /1 s • Frequency: 50 or 60 Hz
• Secondary current: 1 or 5 A
• Frequency: 50 or 60 Hz
9 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W

— —
KOKS 24 DUMMY CT
A current transformer without primary conductor, but A current transformer with bar primary conductor so con-
with primary insulation which can be fitted directly over structed that it can be used as a bushing. TTR current trans-
a conductor or busbar. Suitable for outlets of generator. formers are suitable as a bushing between two AIS compart-
ments, different switchboards, OEM.
Characteristic
• Special type Characteristic
• For measuring an protection with up to 4 secondary wind- • Bar primary bushing type
ings • For measuring and protection with up to 2 secondary
• Most electrical standards available (IEC, AS, BS, ANSI, VDE, windings
CSN, others on request) • Secondary reconnectable versions available
• Secondary reconnectable versions available • Most electrical standards available (IEC, CSN)

Ratings Ratings
• Highest voltage for equipment: 24 kV • Highest voltage for equipment: 3.6 - 24 (25) kV
• Primary current: 1 000 - 8 000 A • Primary current: 100 - 2 500 A
• Rated short - time thermal current: 100 kA /1 s • Rated short - time thermal current: 100 kA /1 s
• Secondary current: 1 or 5 A • Secondary current: 1 or 5 A
• Frequency: 50 or 60 Hz • Frequency: 50 or 60 Hz
V O LTA G E T R A N S F O R M E R S 10


Voltage transformers

— —
TJC TJE
Single phase voltage transformer which is intended to have Single phase voltage transformer which is intended to have
one end of its primary winding directly earthed. TJC voltage one end of its primary winding directly earthed. TJE 3, TJE 4
transformers are suitable for the current air insulated voltage transformers have lower ratings and are suitable for
switchgear portfolio, OEM partners, utilities and many oth- mine switchboards, OEM.
ers.
Characteristic
Characteristic • For measuring and protection with up to 2 secondary
• For measuring an protection with up to 3 secondary windings
windings • Reconnectable versions available
• Reconnectable versions available • Most electrical standards available (IEC, AS, BS, ANSI, VDE,
• Most electrical standards available (IEC, GOST, AS, BS, CSN, others on request)
ANSI, VDE, CSN, others on request) • Non DIN solution, optional DIN baseplate available
• DIN dimensions according to 42600 part 9 • Available variant for voltage 12 - 24 kV ( TJCL)
• Available variant with extended parameters for voltages • Optional transparent secondary terminal cover
3.6 - 17.5 kV (TJCH) • Sealable secondary terminal
• Optional transparent secondary terminal cover
• Suitable for tariff metering Ratings
• Sealable secondary terminal • Highest voltage for equipment: 3.6 - 12 kV
• Primary voltage: 3 000 /√3 - 11 000 /√3 V
Ratings • Secondary voltage: 100 /√3 - 120 /√3, 100 /3 - 120 /3 V
• Highest voltage for equipment: 3.6 - 40.5 kV • Frequency: 50 or 60 Hz
• Primary voltage: 3 000 /√3 - 35 000 /√3 V
• Secondary voltage: 100/√3 - 120/√3, 100/3 - 120/3 V
• Frequency: 50 or 60 Hz
11 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W

— —
TJP TDC
Single phase voltage transformer which is intended to have Double pole voltage transformer which has all parts of its
one end of its primary winding directly earthed. TJP trans- primary winding, including terminals, insulated from the
former is equipped with fuse connected to primary winding. earth at a level corresponding to its rated insulation level.

Characteristic Characteristic
• For measuring and protection with up to 3 secondary • For measuring and protection with up to 2 secondary
windings windings
• Reconnectable versions available • Reconnectable versions available
• Most electrical standards available (IEC, GOST, AS, BS, • Most electrical standards available (IEC, GOST, AS, BS,
ANSI, VDE, CSN, others on request) ANSI, VDE, CSN, others on request)
• DIN dimensions according to 42600 part 9 • DIN dimensions according to 42600 part 9
• Various fuses from 300 mA to 6.3 A • Optional transparent secondary terminal cover
• Various high voltage terminals available (spring, cable con- • Suitable for tariff metering
nection,..) • Sealable secondary terminal
• Available variant with extended parameters for voltages
3.6 - 17.5 kV (TJPH) Ratings
• Optional transparent secondary terminal cover • Highest voltage for equipment: 3.6 - 40.5 kV
• Suitable for tariff metering • Primary voltage: 3 000 - 35 000 V
• Sealable secondary terminal • Secondary voltage: 100 - 120 V
• Frequency: 50 or 60 Hz
Ratings
• Highest voltage for equipment: 3.6 - 40.5 kV
• Primary voltage: 3 000 /√3 - 35 000 /√3 V
• Secondary voltage: 100 /√3 - 120 /√3, 100 /3-120 /3 V
• Frequency: 50 or 60 Hz
V O LTA G E T R A N S F O R M E R S 12

— —
KGUGI KGUG
KGUGI is single pole insulated voltage transformer with high KGUG is double pole insulated voltage transformer with high
power output. power output.

Characteristic Ratings
• Voltage transformers for power supply • Highest voltage for equipment: 24 - 36 kV
• For measuring and protection with up to 2 secondary • Primary voltage: 15 000 - 35 000 V
windings • Secondary voltage: 100 - 120 V
• IEC standard available (another on request) • Thermal burden: up to 2 000 VA
• Frequency: 50 or 60 Hz
Ratings
• Highest voltage for equipment: 24 - 36 kV
• Primary voltage: 15 000 /√3 - 35 000 /√3 V
• Secondary voltage: 100 /√3 - 120/√3, 100 /3 - 120 /3 V
• Thermal burden: up to 2 000 VA
• Frequency: 50 or 60 Hz
VT Guard Pro belongs to a new family of advanced protection de-
13 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L I C AT I O N S P R O D U C T O V E R V I E W

vices that protect VTs against ferroresonant phenomena by proper


and prompt damping action (Fig. 1), without creating excessive
power consumption (as in the case of using ordinary damping
resistors) during normal operation of the network.

VT Guard Pro and VT Guard Pro–D


VT Guard Pro, Pro-D
VT Guard Pro is an security device that protects medium
voltage inductive voltage transformers against ferroreso-
nant oscillation. Ferroresonance can arise in ungrounded

Two versions of the VT Guard Pro are available. power networks or in the networks where is not directly
grounded neutral point. It is designed to be used in open-
Both versions are identical from the functionality point of view delta connection of three single-phase voltage transform-
ers. VT Guard Pro (Pro-D) fully replace dumping resistor and
(damping ability), but the VT Guard Pro–D has extended functions save space in customer application.

that allow self-diagnosis and enableRatings possibility of cooperation


• Rated operational voltage: 100 /110 V AC

with superior system. This diagnostic feature allows the device to


• Voltage range: 0 - 110 V AC
• Maximal operational current: 10 A /0.2 s

check itself (functionality of its circuits) andin lowisvoltage


able
• Nominal frequency: 50 or 60 Hz
• Mounting to send
compartment infor-
of switchgear

mation about its state to a superior system.

Current flowing
Current flowing
through the

through the
primary winding
of the VT
primary winding
of the VT

Voltage on a
Voltage on a
primary terminal
primary terminal
of the VT

of the VT

VT under influence of
VT under influence of ferroresonant oscilation Current
Curent andand
voltagevoltage
after damping after
action

ferroresonant oscilation damping action

VT Guard Pro activated


VT Guard Pro
activated
V O LTA G E T R A N S F O R M E R S 14

ABB s.r.o.
EPDS Brno
Videnska 117, 619 00 Brno,
Czech Republic
Tel.: +420 547 152 021
+420 547 152 854
Fax: +420 547 152 626
www.abb.com

1VLC000576 Rev.3, en 2018.02.19

The data and illustrations are not binding. We reserve the


right to make changes without notice in the course of
technical development of the product.

© Copyright 2018 ABB.


All rights reserved.