Sie sind auf Seite 1von 15

OTHER APPLICATION METERS

COMPONENTS TESTING INSTRUMENT


MODEL Description (Main Function) Page

GOM-805 DC Milli-Ohm Meter 5m ~ 5M E45-47

GOM-804 DC Milli-Ohm Meter 5m ~ 5M E45-47

GOM-801H DC Milli-Ohm Meter 20m ~ 20k E48

GUT-6000B Digital IC Tester E49

GUT-6600A Handy Digital IC Tester E50

PRECISION CURRENT SHUNT METER

MODEL Description (Main Function) Page

PCS-1000I Max. Voltage, AC 600V/DC 1000V, Max. Current, AC 300A/DC 300A E51-54

AUDIO RELATED INSTRUMENT


MODEL Description (Main Function) Page

GAD-201G 20Hz ~ 20kHz Automatic Distortion Meter E55

GVT-427B/417B AC Millivolt Meter (2CH/1CH) E56

OTHER METERS FREQUENCY COUNTER


MODEL Description (Main Function) Page
In order to provide customers with a complete "one stop shopping" solution, GW Instek also offers many other special test and
GFC-8270H 0.01Hz ~ 2.7GHz Intelligent Counter E57
measurement instruments for different applications. For current measurement, PCS-1000I is a high-precision D.C. and A.C. Current
GFC-8131H 0.01Hz ~ 1.3GHz Intelligent Counter E57
Shunt Meter which carries built-in current shunts and high-accuracy current measurement circuits. For power related measurement,
GFC-8010H 10Hz ~ 120MHz Digital Frequency Counter E58
bench-top GPM-8213(A.C./D.C) and GPM-8212(A.C only) power meter is suitable for middle to high-end applications. If you need to
measure the impedance of material components, the GOM-800 Series D.C. milli-ohm meter is your ideal tool. As for audio signals
related measurements, GW Instek provides GAD-201G automatic distortion meter and GVT-417B/GVT-427B A.C. millivolt meters.
We also supply several models of the GFC-8000 Series frequency counters with ranges of 2.7GHz, 1.3GHz and 120MHz. Other special POWER RELATED INSTRUMENT
application instruments such as digital IC tester and logic probe (pulser included) are also available.

OTHER METERS
MODEL Description (Main Function) Page

A.C./D.C Power Meter Simultaneous Display of W, A, V (PF or Hz)


GPM-8213 E59-62
PRODUCTS True RMS V, A, W; Max./Min./Hold Function

DC Milli-Ohm Meter A.C. Power Meter Simultaneous Display of W, A, V (PF or Hz)


GPM-8212 E63
Digital IC Tester True RMS V, A, W; Max./Min./Hold Function

Precision Current Shunt Meter


Digital Power Meter
OTHER
AC Power Meter
MODEL Description (Main Function) Page
Automatic Distortion Meter
AC Millvolt Meter GLP-1A Logic Probe & Pulser E64

Frequency Counter
Logic Probe & Pulser

E43 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E54
E44
D.C. Milli-Ohm Meter
GW Instek launch a new series of D.C. milliohm meter_GOM-804/805, which abundantly feature
3.5-inch TFT display, maximum 50,000 counts measurement display, the rapid sampling rate of 60
readings per second, optimum 0.05% measurement precision, four wire measurement method as well
as the temperature measurement and temperature compensation measurement function to meet the
requirement of low resistance measurement application. The GOM-805 also includes various drive Rear Panel
modes and Dry circuit for contact resistance measurement applications. More features, including
20 sets of panel setting memory and many external control interface such as RS-232C, USB, Handler/
Scan/EXT IO or GPIB (option), greatly elevate GOM-804/805 milliohm meter's convenience on
practical applications.
GOM-804/805 adopt 3.5-inch color LCD to enhance the clarity of measurement results and to provide
display for related setting criteria that tremendously brings up the completeness of test information.
Additionally, GOM-804/805, with the optimum 0.05% precision, augment the measurement speed to
GOM-804/805 60 sampling rate per second and maintain the display digits of five instead of four despite of different
speed selections. Furthermore, the independent functionality keys and direction keys together increase
USB the operational convenience which allows users to complete their measurement tasks with intuitive
Device convenience and speed. GOM-804/805
GOM-805 provides Dry circuit and various drive modes (DC+, DC-, Pulsed, PWM) for measurement
Handler EXT I/O
applications on different materials. The pulsed current output mode is suitable for interacting SPECIFICATIONS GTL-308 Test lead
conductors of different materials and this output mode is to reduce the thermal EMF influence, which GOM-804 GOM-805 Approx. 1.5m
is caused by electric potential difference generated from different conductors acting on different
DRIVE MODE
temperatures while conducting low resistance measurements. The DC+ and DC- output modes are best
FEATURES for the measurement requirements of inductive components. The PWM output mode, ideal for DC+ / DC-
changing temperature sensitive materials, can avoid resistance value variation which is due to over load PULSED
* 50,000 Counts Display Yes
happened on current measurement for a long period of time. During the DC+, DC- and Pulsed drive is PWM
* 3.5” (320 x 240) TFT LCD Display ZERO
supplied; the Dry circuit can work with them also. Dry circuit can limit the applied voltage under the
* High Accuracy of 0.05% Precision OTHER FUNCTIONS
open circuit voltage of 20mV to avoid over voltage occurred on the both ends of components. The over
* 1Amp Test Current, 0.1µΩ Resolution voltage will damage the oxide coating and the thin layer of contact surface, as a result, the validity of Trigger - Internal, Manual, External; Math - ABS, REL, %, TC;
* Fast Measurement of 60 Readings Per Second measurement will then be ruined. For instance, contact resistance of connector measurement is one of Average : 2 ~10 times; Measurement Delay; TC for Transformer;
the applications. Compare; Diode; Continuity beeper; Binning (GOM-805 only)
* Four wire Resistance Measurement
INTERFACE
* Temperature Compensation Measurement With respect to connecting the external control, GOM-804/805 provide a D-sub 25-pin combined
USB Standard Standard PT-100 Temperature Probe
Function interface to execute, according to the functionalities, Handler, Scan or EXT IO for respectively connecting
RS-232C Standard Standard Approx. 1.5m
* Delayed Measurement to a sorting machine; connecting to an external on-off switch, and directly conducting external trigger Standard Standard
HANDLER/SCAN/EXT I/O
control. For remote control and measurement result retrieval requirements, GOM-804/805 also provide GPIB Option Standard
* 20 sets of Panel Setting Memory
various interface selections such as RS-232C, USB, and GPIB (GOM-804(option)/GOM-805(standard)
* Dry Circuit (GOM-805 Only) DISPLAY
interface. Furthermore, the control commands are compatible to that of GOM-802 that saves time in
* Drive Modes : DC+/DC-, Pulsed, PWM, 3.5"(320 x 240) TFT LCD
adjusting programs while switching from the old model to the new model.
MEMORY
Zero(GOM-805 Only) To sum up, GOM-804 evolves from GOM-802 platform with more advanced functionalities and
20 sets for panel setting
* Interface : USB Device, RS-232C, Handler/ specifications, including display digits, measurement speed and standard interface (RS-232C/USB).
With all the capabilities of GOM-804, GOM-805 augments itself with new measurement abilities (Dry POWER SOURCE
Scan/EXT I/O, and GPIB (Option) AC 100 ~ 240 V, 50/60Hz
circuit and various drive modes) to meet the requirements of broader low resistance measurement
applications. COMSUMPTION
25VA ( max. )
GOM-804/805

GOM-804/805
SPECIFICATIONS DIMENSIONS & WEIGHT
223(W) x 102(H) x 283(D) mm ; Approx. 3kg
GOM-804 GOM-805
DISPLAY
50,000 counts ORDERING INFORMATION
SAMPLING RATE GOM-805 D.C. Milliohm Meter(Handler/RS-232C/USB Device/GPIB)
Slow 10 readings / s GOM-804 with GPIB D.C. Milliohm Meter(Handler/RS-232C/USB Device/Opt.01 GPIB)
Fast 60 readings / s GOM-804 D.C. Milliohm Meter(Handler/RS-232C/USB Device)
RESISTANCE MEASUREMENT
OTHER METERS

OTHER METERS
ACCESSORIES :
Range Resolution Test Current Accuracy Quick Start Guide x 1, Power cord x 1, Test lead GTL-308 x 1, CD x 1 (complete user manual)
5mΩ 0.1μΩ 1A ±(0.1% reading + 0.2% of range)
OPTION
50mΩ 1μΩ 1A ±(0.1% reading + 0.02% of range)
Opt.01 GPIB Card (only for GOM-804 and must be installed at factory before shipment)
500mΩ 10μΩ 100mA ±(0.05% reading + 0.02% of range)
OPTIONAL ACCESSORIES
5Ω 100μΩ 100mA ±(0.05% reading + 0.02% of range)
50Ω 1mΩ 10mA ±(0.05% reading + 0.02% of range) PT-100 Platinum Temperature Probe
500Ω 10mΩ 1mA ±(0.05% reading + 0.008% of range) GTL-232 RS-232C cable 9-pin, F-F type, approx. 2000mm
5kΩ 100mΩ 100μA ±(0.05% reading + 0.008% of range) GTL-246 USB cable, A-B type, approx. 1200mm
50kΩ 1Ω 100μA ±(0.05% reading + 0.008% of range) GTL-248 GPIB cable approx. 2000mm
500kΩ 10Ω 10μA ±(0.05% reading + 0.008% of range) GTL-251 GPIB-USB-HS+(high speed) adaptor
5MΩ 100Ω 1μA ±(0.2% reading + 0.008% of range) FREE DOWNLOAD
Driver LabView Driver
TEMPERATURE
Range -50˚C ~ 399.9˚C
Accuracy -10˚C ~ 40˚C : 0.3% 0.5˚C ; Other : 0.3% 1.0˚C
Resolution 0.1˚C
DRY CIRCUIT
Open circuit less than 20mV;
For 500mΩ, 5Ω, 50Ω range only

E45 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E46
D.C. Milli-Ohm Meter
A. TOTALLY REPLACING THE EXISTING MODELS D. VARIOUS DRIVE MODES FOR GOM-805 ONLY

PWM Mode
PWM ON PWM OFF
3~99 UNIT 1~9999ms
50ms 1000ms

Current

Time
1 U NIT : at 60Hz = 16.6ms, at 50Hz = 20ms

In terms of the basic functionalities and specifications, GOM-804/805 etc.The programming commands are also compatible to that of GOM-802. GOM-805 provides various current output drive modes to satisfy The PWM output mode, ideal for changing temperature sensitive
can absolutely replace the existing model_GOM-802. All GOM-802 To simply put it, the brand new GOM-804/805 not only provide better diversified and accurate low resistance measurement applications. For materials, can avoid resistance value variation which is due to over load
functionalities can be found from GOM-804/805, including resistance display interface, fast measurement (60 readings per second), but also instance, for interacting conductors of different materials, the pulsed on large current measurement in a long period of time. The DC+ and
measurement range, 1A test current (maximum), four wire measurement collocate with standard communications interface (RS-232C/USB device) current output mode can be applied to reduce the thermal EMF influence, DC- output modes are best for the measurement requirements of
method, temperature probe (option, accessory model : PT-100) for to facilitate users in accomplishing measurement tasks rapidly. On top which is caused by different conductors acting on different temperatures. inductive components.
temperature measurement and temperature compensation measurement, of that, model switching will not be a problem.

B. FASTER MEASUREMENT WITHOUT SACRIFICING RESOLUTION E. STANDARD INTERFACE FOR CONTROL AND COMMUNICATIONS

Slow Fast

GOM-804/805 has two measurement speed selections, which are Fast despite of any speed selections and will maintain the highest display
With respect to connecting the external control, GOM-804/805 provide selections such as RS-232C, USB, and GPIB GOM-804(option)/GOM-805
reaching 60 readings per second, and Slow 10 readings per second. A digits. In other words, reading resolution will not be changed by
a D-sub 25-pin composite interface to execute, according to the (standard) interface. The commands of GOM-804/805 are compatible to
major departure from the past, users, in the past, had to juggle between changing speed and the display digits remain the same.
functionalities, Handler, Scan or EXT IO for connecting to a sorting that of GOM-802 that allows users to switch equipment with simple
speed and display resolution. GOM-804/805 will not affect resolution
GOM-804/805

GOM-804/805
machine; connecting to an external on-off switch, and directly conducting settings. There is no cost in adjusting existing programs and production
external trigger control respectively. For remote control and measurement delay will not be happening while switching from the old model to the
C. DRY CIRCUIT TEST FOR GOM-805 ONLY result retrieval requirements, GOM-804/805 also provide various interface new model.

Dry Circuit
Sense +
OTHER METERS

OTHER METERS
Force +
Dry
Circuit
GOM-
Volt
805 Meter Voltage
Limiter DUT
100mA
10mA
1mA
Force -

Sense -

Dry circuit is to limit test voltage and current to certain levels which will not to avoid over voltage for the both ends of components. The over voltage
cause contact points to produce physically or electrically changed circuit will damage the oxide coating and the thin layer of contact surface, as a
and its most frequently used application is contact resistance of connector result, the validity of measurement will then be ruined. GOM-805
measurement. Based upon MIL-STD-1344 method 3002-1 low signal level provides three levels (500mΩ:100mA/5Ω:10mA/50Ω:1mA) to limit
contact resistance, tests must be applied under the maximum open circuit open circuit voltage at 20mV to execute Dry circuit tests.
voltage of 20mV (or lower), and short circuit current of 100mA (or lower)

E47 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E48
D.C. Milli-Ohm Meter Handy Digital IC Tester
GOM-801H milliohm meter is the ideal device for quick and precise component and material GUT-6600A is a portable digital IC tester with features matching those of its desktop
resistance measurements. The main display is equipped with a 3 1/2 digit 0.5" red LED with cousin, GUT-6000B. Standard DC adaptor operation or battery provides a secure power
comparator indicators. Measurable objects can cover cable joints, earth bonds, switches, motors, supply anytime, anywhere. geared towards ease of use, no programming or fixtures are
transformers and generators. The front panel features seven selectable test ranges, 20m to 20k required when operating GUT-6600A; users simply have to plug in the device and a search
The internal comparator is fully adjustable for the user settable Hi/Lo comparison indicator. is completed within a mere 0.6 seconds on average. All these features and compact profile
GOM-801H is the best choice for an inexpensive, easy to use, yet reliable milliohm meter. make GUT-6600A the ideal choice as an additional companion in a users' tool kit.

SPECIFICATIONS
TEST RANGE
GOM-801H TTL 74/54 ; CMOS 40/45 ; DRIVE 2xxx
GUT-6600A TEST VOLTAGE
2.5/3.0/3.3/5V
TEST TIME
Average Search Time : 0.6Sec
DISPLAY
16 Characters in 1 line LCD
FEATURES SPECIFICATIONS FEATURES POWER SOURCE
TEST RANGE
* 3 1/2 Digits 0.5" LED Display DC 9V/500mA adaptor or 9V battery x 2(*)
20, 200mW , 2, 20, 200W , 2k, 20k W , * Easy-Operation Tester, Particularly Designed
* Measures from 20m ~ 20k in 7 Ranges DIMENSIONS & WEIGHT
7 Ranges for the Digital IC
* 1A High Test Current 110(W) x 45(H) x 160(D)mm, Approx. 0.4kg
TEST CURRENT (Test Voltage 0.2V) * Supported Device : 74/54/40/45, Drive 2xxx
* High Resolution 10 20m W /200mW : 1A (*) Batteries not included
* Small, Portable, Light and Power-Saving
2 W : 0.1A
* Hi/Lo Comparator Indicator and Buzz Alarm 20 W : 10mA * Can be Operated using either DC adaptor or ORDERING INFORMATION
200 W : 1mA Batteries GUT-6600A Handy Digital IC Tester
2k W : 100 A * Average Search Time : 0.6 Second
20k W : 10 A ACCESSORIES :
* Display : 16 Characters in 1 Line LCD
ACCURACY User manual × 1 , Power cord × 1(GUT-6000B);User manual x 1, DC 9V/500mA adaptor(GUT-6600A)
20m W +
_ (0.2% rdg + 6 digits)
* Test Pins : 14 ~ 24 Pins
200m W ~ 20k W +
_ (0.2% rdg + 4 digits)
RESOLUTION
GTL-108A 4W Test Lead 0.01mW , 0.1m W , 1m W , 10mW , 100m W , 1W , 10 W
Approx. 1.1m COMPARATOR

DISPLAY
HI, LO settable
Digital IC Tester
3 1/2 digits 0.5" LED display
HI, GO, LO indicator
GUT-6000B is a desktop digital IC tester. Oriented toward automating testing tasks, GUT-
POWER SOURCE
AC 100V/120V/220V/230V +
_ 10% , 50/60Hz ; Power Comsumption : Max. 25VA 6000B contains high-end features such as auto-search and loop testing. Automated

GUT-6600A/6000B
DIMENSIONS & WEIGHT processes provide an intelligent and continuous process for detecting defective ICs.
Self-diagnosis functions and over-load protection mechanisms make GUT-6000B close to
GOM-801H

230(W) x 95(H)x280(D)mm, Approx. 2 kg


maintenance-free, releasing users from unnecessary hassles. The wide device coverage
ORDERING INFORMATION includes the 1800 series as well as the ubiquitous TTL and CMOS, providing a one-size
GOM-801H High Precision DC Milli-Ohm Meter
fits-all solution for an IC testing bench area.
ACCESSORIES :
User manual x 1 , Power cord x 1
Test Lead GTL-108A x 1 GUT-6000B SPECIFICATIONS
OTHER METERS

OTHER METERS
TEST RANGE
TTL 74/54 ; CMOS 40/45 ; DRIVE
TEST VOLTAGE
2.5/3.0/3.3/5V
TEST TIME
FEATURES Average Search Time : 0.6Sec
DISPLAY
* Loop Test 16Characters in 1 line LCD
* Auto-Search POWER SOURCE
* Self-Diagnosis AC100V~240V±10%,50/60Hz
* Over-Load Protection DIMENSIONS & WEIGHT
* Measures 1800 Types of Device 335(W) ×105(H) ×300(D)mm, Approx. 1.5kg
* 54/74 Series TTL (*) Batteries not included
* 4000 and 4500 Series CMOS
ORDERING INFORMATION
* Test Socket : 28-Pin
GUT-6000B Digital IC Tester
ACCESSORIES :
User manual × 1,Power cord × 1(GUT-6000B),User manual x 1,DC 9V/500mA adaptor(GUT-6600A)

E49 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E50
Isolated Output High Precision Current Shunt Meter

GW Instek rolls out the new PCS-1000I isolated output high precision current shunt meter, which
inherits the simultaneous voltage and current measurement function of PCS-1000. PCS-1000I adopts Rear Panel
five sets of independent shunt resistors to provide five current measurement levels, including 300A,
30A, 3A, 300mA, and 30mA to meet the requirements of different current level measurements.
Internally, PCS-1000I utilizes two sets of 24bits ADCs and low temperature coefficient electronic
components to mainly focus on the current measurement of power supply devices. High precision
PCS-1000I can be used in adjusting and calibrating instruments. Additionally, temperature variation
will not cause PCS-1000I to yield any measurement errors. PCS-1000I can automatically select optimal
measurement level with the maximum resolution so as to replace manual selection to save operational
PCS-1000I time.

PCS-1000I provides a BNC output, which can connect with an oscilloscope to directly observe current
waveform variation without using a current probe. General oscilloscopes do not have isolated channels PCS-1000I
and their input and output are structured at a common point, therefore, the output load will likely
result in measurement errors. PCS-1000I's isolated current output design can prevent measurement SPECIFICATIONS
FEATURES errors from an oscilloscope with non-isolated outputs. PCS-1000I, a high precision AC/DC current
Isolated AC Current Monitor Accuracy
* 6 1/2 Digit Voltage and Current Measurement shunt meter, not only provides USB and GPIB communications interfaces for users to remotely control
Resolution the instrument but also conducts simultaneous voltage and current measurements. The SCPI Range Frequency AC Accuracy Temperature Coefficient/℃
* Simultaneous Current and Voltage communications commands of PCS-1000I allow users to remotely control PCS-1000I via a PC to 30 . 00000 mA 0.001
45Hz ~ 2kHz 0.2 + 0.05
300 . 0000 mA 0.001
Measurement operate measurement data read backs. 2kHz ~ 10kHz 0 . 5 + 0.05
3 . 000000 A 0.001
* Five Current Measurement Levels(AC & DC) : 30 . 00000 A * 1 0.001
SPECIFICATIONS 45Hz ~ 400Hz 0.5 + 0.05
30mA/300mA/3A/30A/300A 300 . 0000 A * 1 0.001
* AC Voltage Measurement Levels : DC CHARACTERISTICS Accuracy specification : ±(% of output + % of full scale); monitor output voltage for the full scale current
200mV/2V/20V/200V/600V DC Voltage = 3V; The specifications are only applicable when the input is 10% or greater of the full scale range
* DC Voltage Measurement Levels : Range 1 Year 23 ℃ ± 5 ℃ Temperature Coefficient/℃ GENERAL
200mV/2V/20V/200V/1000V 200.0000 mV 0.0050 + 0.0035 0.0005 + 0.0005 Power Supply 100 V/120 V/220 V/240 V ±10%
2.000000 V 0.0050 + 0.0010 0.0005 + 0.0001 Power Line Frequency 50/60 Hz
* Standard : USB & GPIB
20.00000 V 0.0050 + 0.0010 0.0005 + 0.0001 Operating Environment Full accuracy for 0 ℃ ~ 55 ℃, Full accuracy to 80% R.H. at 40 ℃
* CE Verification
200.0000 V 0.0050 + 0.0010 0.0005 + 0.0001 Storage Environment -40 ℃ ~ 70 ℃
1000.000 V 0.0050 + 0.0020 0.0005 + 0.0001 Power Consumption Max 35VA
Accuracy specification : ±(% of reading + % of range);voltage input resistance: 10MΩ for all DC voltage ranges Dimensions Weight 210(W) x 80(H) x 390(D)mm ; Approx. 5 kg
DC Current
(The specifications apply when the PCS-1000I is powered on for at least 30 minutes to warm-up to a temperature of 18 ℃~ 28 ℃,
Range Burden Voltage 1 Year 23 ℃ ± 5 ℃ Temperature Coefficient/℃ unless specified otherwise.)
Note: *1 The accuracy for 30A/300A levels must be increased by a power factor of 8 ppm/watt.
30 . 00000 mA < 0.4 V 0.01 + 0 . 005 0.001 + 0 . 002
300 . 0000 mA < 0.5 V 0.01 + 0 . 005 0.001 + 0 . 002 ORDERING INFORMATION
3 . 000000 A < 0.8 V 0.01 + 0 . 005 0.001 + 0 . 002 PCS-1000I Isolated Output High Precision Current Shunt Meter
30 . 00000 A * 1 < 0.8 V 0.01 + 0 . 005 0.001 + 0 . 002
ACCESSORIES :
300 . 0000 A * 1 < 0.8 V 0.02 + 0 . 005 0.001 + 0 . 002
Quick Operation Guide, User Manual (CD) x 1, AC Power Cord x 1 (Region Dependant)
Accuracy specification : ± (% of reading + % of range)
GTL-105A Alligator Clip Test Lead (3A Max)
PCS-1000I

PCS-1000I
Isolated DC Current Monitor Accuracy
GTL-207A Banana Plug Test Lead
Range Resolution(6 1/2) DC Accuracy Temperature Coefficient/℃ GTL-240 USB Cable
30 . 00000 mA 0.00001mA 0.1 + 0 . 05 0.001 PCS-001 Basic Accessory Kit
300 . 0000 mA 0.0001mA 0.1 + 0 . 05 0.001 OPTIONAL ACCESSORIES
3 . 000000 A 0.000001A 0.1 + 0 . 05 0.001 GRA-419-J Rack Mount Kit (JIS)
30 . 00000 A * 1 0.00001A 0.1 + 0 . 05 0.001 GRA-419-E Rack Mount Kit (EIA)
300 . 0000 A * 1 0.0001A 0.2 + 0 . 05 0.001
OTHER METERS

OTHER METERS
Accuracy specification : ±(% of output + % of full scale);monitor output voltage for the full scale current = 3V
AC CHARACTERISTICS PCS-1000I
True RMS AC Voltage
VS. Current Probe for
Range Frequency 1 Year 23 ℃ ± 5 ℃ Temperature Coefficient/℃
Measurement
200 . 0000 mV 0.005 + 0 . 005
2 . 000000 V 45Hz ~ 2kHz 0.5 + 0.05 0.005 + 0 . 005
20 . 00000 V 2kHz ~ 10kHz 1.0 + 0.05 0.005 + 0 . 005
200 . 0000 V 10kHz ~ 20kHz 2.0 + 0.10 0.005 + 0 . 005
600 . 000 V 0.005 + 0 . 005
Accuracy specification : ±(% of reading + % of range)
True RMS AC Current
Range Frequency 1 Year 23 ℃ ± 5 ℃ Temperature Coefficient/℃
The Measurement Issue
30 . 00000 mA 0.03 + 0 . 006
45Hz ~ 2kHz 0.5 + 0.05
0.03 + 0 . 006 for Non-Isolated Shunt Meter
300 . 0000 mA
2kHz ~ 10kHz 1.0 + 0.05
3.000000 A 0.03 + 0 . 006
30 . 00000 A * 1 0.03 + 0 . 006
45Hz ~ 400Hz 0.5 + 0.05
300 . 0000 A * 1 0.03 + 0 . 006
Accuracy specification : ±(% of reading + % of range)

E51 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E52
Isolated Output High Precision Current Shunt Meter

A. SIMULTANEOUS VOLTAGE AND CURRENT MEASUREMENT D. ISOLATED OUTPUT CURRENT OUTPUT DESIGN

PCS-1000I adopts isolated current output design. Its BNC output


can directly connect with an oscilloscope to avoid measurement
errors resulted from the common ground of oscilloscope's
analog input measurement.

PCS-1000I high precision AC and DC shunt meter can simultaneously simultaneous measurement. Compared with the test of conventional
measure current and voltage with the maximum 6 1/2 measurement meters from other brands, PCS-1000I is simple in connection
resolution. The above diagram shows the connection method of and there is no requirement of any additional instrument.
E. AUTOMATIC RANGE-SWITCHING MEASUREMENT FUNCTION

B. FIVE SETS OF SHUNT RESISTORS TO SWITCH MEASUREMENT Press and hold Auto key, PCS-1000I will automatically select
the maximum measurement resolution for users to save time
in manual selection.

F. CONNECTION COMPARISON
The switching measurement of five independent shunt resistors Under 30mA range, the resolution is 0.01uA, which is ideal for
provides excellent resolution than that of a single shunt resistor. very small current measurement.
PCS-1000I can simultaneously measure current and voltage with 6 1/2 measurement resolution. The left diagram shows the
connection method of simultaneous measurement. Compared with the test of conventional meters from other brands, PCS-1000I
is simple in connection and there is no requirement of any additional instrument.
PCS-1000I

PCS-1000I
C. REMOTE CONTROL APPLICATION
PCS-1000i Conducts Simultaneous Voltage Shunt Resistor Conducts Current and Voltage Conventional Shunt Meter Conducts Current
and Current Measurement Measurement and Voltage Measurement
OTHER METERS

OTHER METERS
1. Only one PCS-1000I is needed to measure 1. One voltage meter is needed to measure voltage 1. This method requires one shunt meter, one
PCS-1000I is not only a high precision AC/DC shunt meter but also provides PCS-1000I and DUT and the parallel connection between voltage input voltage and current on shunt and the voltage will be converted to current meter to increase current
users with USB and GPIB communications interface so as to remotely and DUT are arranged to conduct simultaneous voltage and current 2. Easy connection current. For simultaneous voltage and current measurement resolution, and one voltage
control operational sequence. The SCPI commands of PCS-1000I allow measurement on DUT. Via the connection between communications 3. USB and GPIB communications on the rear measurement, one extra voltage meter is required meter to measure voltage
panel can be used for data communication 2. Complex connection 2. Complex connection
users to read back measurement value via a computer remotely controlling and a notebook computer, PCS-1000I can be remotely controlled by
while connecting with a PC 3. For data communication with a PC, the PC must 3. For data communication with a PC, the PC
PCS-1000I. As shown on the above diagram, the series connection between operating the notebook computer and edited sequence. be connected to two voltage meters must be connected to two meters

E53 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E54
Automatic Distortion Meter A.C. Millivolt Meter
The GAD-201G distortion meter is aimed at total harmonic distortion (THD) and AC voltage The GVT-427B/417B Series is a compact analog AC millivoltmeter ideal for low level voltage
measurement at audio frequency range, from 20 ~ 20kHz. Frequency and voltage are displayed measurements with a remarkable 300 V full scale sensitivity. GVT-427 has dual independent
simultaneously on dual meters, with measurement range automatically switching over full scale. channels that can be used simultaneously or separately for measurement. Voltage scale is separated
The frequency keys cover 400Hz, 1kHz, and 10kHz for commonly used measurement frequencies. into 12 ranges, easily accessible by the large rotary selector. The wide measurement range, frequency
The output terminals can feed basic waveforms (X) and harmonic distortion (Y) to an external (10Hz ~ 1MHz) and voltage (-70dB ~ +40dB), provides ample headroom for most applications.
monitoring device. Residual distortion, including hum and noise, is kept to a minimum level of
0.03%, making GAD-201G ideal for high-end audio applications.

GAD-201G GVT-427B (2CH)

FEATURES SPECIFICATIONS SPECIFICATIONS


DISTORTION MEASUREMENT INPUT
* Automatic Level & Distortion Measurements Voltage Range 300 V ~ 100V of Full Scale in 12 ranges
Range 0.1% ~ 100% full scale in 7 ranges by
* Auto or Hold Function Can be Selectable auto ranging Decibel Range -70dB ~ +40dB in 12 ranges
* 0.1% ~ 100% in 7 Distortion Measuring Ranges Accuracy _+3% of full scale
Fundamental Frequency Range 20Hz ~ 20kHz in 3 continuous ranges with fine adjustment Operating Mode GVT-427B : Ch1 and Ch2 separately or simultaneously at Ch1
* 20Hz ~ 20kHz in 3 Continuous Ranges tuning and 3 spots for 400Hz, 1kHz and 10kHz only
GVT-417B : one Ch1 only
* 400Hz, 1kHz, 10kHz 3 Spot Frequency Input Level 100mVrms ~ 300Vrms Frequency Response 20Hz ~ 200kHz_ + 3%,10Hz ~ 1MHz + _10%
* 1mVrms ~ 300Vrms in 12 ACV Measuring Automatic Level Control Range _10dB
+ GVT-417B (1CH) (reference 1 kHz)
Ranges Fundamental Rejection 80dB or above Impedance 1MW , approx, 40pF
Second Harmonic Accuracy _ 1dB at a basic frequency of 20Hz ~ 20kHz
Within+
Residual Distortion (Including hum and noise) Less than 0.03% OUTPUT
AC VOLTAGE MEASUREMENT Level Approx. 0.1Vrms at full scale
Distortion Less than 2%
Range 1mVrms to 300Vrms full scale in 12 ranges by auto ranging
_1dB POWER SOURCE
Frequency Response 20Hz ~ 200kHz + FEATURES
_ 10%, 70pF or less(Unbalanced) _10% , 50/60Hz; Power Comsumption : Max. 10VA
AC 115V/230V +
Input Impedance 100kW +
_ 3% of full scale (at 1kHz) * 300 V Full Scale Sensitivity DIMENSIONS & WEIGHT
Accuracy Within +
* Measures Frequency From 10Hz ~ 1MHz 130(W) x 210(H) x 295(D)mm; Approx. 2.8 kg
Residual Noise Less than 10 V (input short circuited)
Output Level X : 1Vrms, Y : 500mVrms at meter full scale * Measures From -70dB ~ +40dB in 12 Ranges
Output Impedance Approx. 600 W * Dual Channel ( GVT-427B ) ORDERING INFORMATION
GVT-427B 2 Channels AC Millivolt Meter
POWER SOURCE
_ 10%, 50/60Hz; Power Comsumption : Max. 25VA
GVT-417B 1 Channel AC Millivolt Meter
AC 100V/120V/220V/240V +
GTL-103 Test Lead DIMENSIONS & WEIGHT GTL-101 Test Lead ACCESSORIES :

GVT-427B/417B
310(W) x 165(H) x 300(D)mm, Approx. 4.6 kg User manual x 1 , Power cord x 1
Banana-Alligator Heads BNC-Alligator Heads Test Lead GTL-101 x 2 for GVT-427B
GAD-201G

Approx. 1.2m Approx. 1.2m Test Lead GTL-101 x 1 for GVT-417B


ORDERING INFORMATION
GAD-201G Automatic Distortion Meter Note : GVT-427B Without Approved
ACCESSORIES :
User manual x 1 , Power cord x 1
Test lead GTL-103 x 1
OTHER METERS

OTHER METERS
E55 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E56
Intelligent Counter Digital Frequency Counter
The GFC-8000 Series performs virtually all of the counting measurements required in laboratories, in GFC-8010H is a Digital Frequency Counter, particularly suitable for educational and laboratory use.
terms of both period and frequency. A bright red 8 digit LED display with an included overflow indicator It features a stable 5ppm time base, a low pass filter and an overflow indicator with a maximum
provides a clear view. Both models feature a stable time base with a maximum resolution of 100nHz operating rate of 120MHz. The clear 8 digit LED display coupled with a quick easy-to-use interface
and 10nS at 1Hz for frequency and period measurement, respectively. Gate time can be configured makes it a handy instrument on any bench-top.
for fast response (5 digits/10ms) or accuracy (7 digits/s) for more control. For high frequency needs,
GFC-8270H can operate at up to 2.7GHz. The GFC-8000 Series features easy operation with a simple
front panel interface, suitable for both portable and bench-top use.

GFC-8270H (2.7GHz) GFC-8010H (120MHz)


GFC-8131H (1.3GHz)

FEATURES SPECIFICATIONS FEATURES SPECIFICATIONS


DISPLAY MAIN
* Frequency and Period Measurement 8 digits with Hz, kHz, MHz, GHz, S, mS, S, nS and overflow * 10Hz ~ 120MHz Range
Display 8 Digit with Hz, kHz, MHz, S, mS, S, nS and overflow
* High Resolution at Both High and Low GATE TIME * 8 Digit Display (0.3" LED) Gate Time 0.1S , 1S , 10 S switch selectable
Frequency Variable from 10ms to 10s, or 1 period of input depending on whichever is greater * 15mVrms High Sensitivity Accuracy _( 1 Digit + Time base accuracy )
+
* 0.01Hz~2.7GHz Frequency Range(GFC-8270H) ACCURACY
+
_ (Resolution +
_ timebase error) * 5ppm High Stability Time Base INPUT
* 0.01Hz~1.3GHz Frequency Range(GFC-8131H) * Frequency and Period Measurement Sensitivity 10Hz ~ 10MHz < 15mVrms
CHANNEL A
* 10mV rms High Sensitivity 10MHz ~ 40MHz < 20mVrms
Range DC coupled 0.01Hz ~ 120MHz * Low Pass Filter Function
* 100nHz Resolution for 1Hz 40MHz ~ 80MHz < 35mVrms
AC coupled 30Hz ~ 120MHz * Over-Flow Indicator 80MHz ~ 120MHz < 50mVrms
* Variable Trigger Level Control Sensitivity 10mV rms typical, 50mV rms max
Coupling AC or DC, switchable Impedance 1M //35pF
* Microprocessor Controlled Intelligent Filter Low pass, switchable in or out for channel A Coupling System AC Coupling
Counter(Only GFC-8270H) -3dB point of nominally 100kHz Max Input Voltage 150Vrms
Impedance 1MW //40pF
TIME BASE
Attenuator 1/1 or 1/20dB
Trigger Level -2.5 VDC ~ + 2.5 VDC Oscillation Frequency 10MHz
Aging Rate _ 1 ppm per month
+
Adjustment
Resolution For frequency measurement, the maximum resolution is 100nHz for 1Hz Temp. Stability _5 C : +
25 C + _ 5ppm
and 0.1Hz for 100MHz inputs respectively. RESOLUTION
For period measurement, the maximum resolution is 10nS for 1Hz and 0.1x10 S The maximum resolution is 1 Hz for 10Hz and 0.1Hz for 100MHz
GTL-101 Test Lead for 100MHz inputs respectively. Input respectively for frequency measurement and 1nS for 10Hz and 0.1 x 10 for 100MHz
At least, the display is 7 digits for 1sec, 6 digits for 100ms, 5 digits for 10ms
BNC-Alligator Heads gate time respectively. POWER SOURCE
Approx. 1.1m Period Range 8nS to 100S at least 7 digits displayed for per second of gate time _ 10% , 50/60Hz ; Power Comsumption : Max. 5Watts
AC 100V/120V/220V/230V +
GFC-8270H/8131H

CHANNEL B DIMENSIONS & WEIGHT


Range
GTL-101 Test Lead 230(W) x 95(H) x 280(D) mm, Approx. 1.7kg
50MHz ~ 2.7GHz for GFC-8270H

GFC-8010H
50MHz ~ 1.3GHz for GFC-8131H BNC-Alligator Heads
Sensitivity _ 50mVrms (10mVrms typical) for GFC-8270H
< Approx. 1.1m
_ 40mVrms (10mVrms typical) for GFC-8131H
<
ORDERING INFORMATION
Coupling AC only GFC-8010H 120MHz Digital Frequency Counter
TIME BASE ACCESSORIES :
Aging rate 1ppm per Month User Manual x 1 , Power cord x 1
Temperature 5ppm 23 C 5 C Test Lead GTL-101 x 1
Line variation _ 10% variation
0.005ppm for + OPTIONAL ACCESSORIES
OTHER METERS

OTHER METERS
GTL-110 Test Lead POWER SOURCE GTL-110 BNC Cable, BNC(P/M)-BNC(P/M), 1000mm
BNC-BNC Heads AC 100V/120V/220V/230V 10%, 50/60Hz ; Power Comsumption : Max. 15VA
Approx. 1m DIMENSIONS & WEIGHT
230(W) x 95(H) x 280(D)mm, Approx. 2.2kg

ORDERING INFORMATION
GFC-8131H 1.3GHz Intelligent Counter
GFC-8270H 2.7GHz Intelligent Counter
ACCESSORIES :
User manual x 1 , Power cord x 1 , GTL-110 x 1 , GTL-101 x 1

E57 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E58
Digital Power Meter
GPM-8213 power meter is designed specifically for single-phase (1P/2W) AC power supply's power
measurements. Powerful features, including 4” TFT LCD, five-digit measurement display, 19 power
measurement parameters, integral measurement function, high-accuracy voltage/current/power
measurement capabilities, front/rear panel input terminals, and various communications ports, are to
facilitate users with clear, convenient, and accurate power measurements. Rear Panel
GPM-8213 provides as many as 19 power measurement parameters, including voltage(Vrms/V+pk/V-pk),
current (Irms/I+pk/I-pk), frequency (VHz/IHz), power (P/P+pk/P-pk), crest factor (CFV/CFI), apparent
power (VA), reactive power (VAR), power factor (PF), phase angle (DEG), total harmonic distortion
(THDV/THDI), high-accuracy voltage/current/power measurement capabilities (reading: ±0.1%; level:
±0.1%). The advantages of TFT LCD have been efficiently deployed to simple mode and standard mode.
Simple mode displays conventional power meter's four measurement parameters to meet the
GPM-8213 requirement of accuracy and clarity for the test on manufacturing process. Standard mode extends the
display to the maximum of 8 measurement parameters (2 major measurements + 6 monitor
measurements) to satisfy the various measurement application requirements of R&D, design, and
USB LAN
Device quality verification.
GPM-8213
For DUT requiring IEC 62301/EN 50564 standby power consumption test, GPM-8213 provides the
optimal measurement supports, including test frequency bandwidth of DC~6kHz, the minimum current
FEATURES level of 5mA (resolution: 0.1uA), power measurement resolutions (1uW for minimum current and SPECIFICATIONS GPM-001 Test Fixture/Test Fixture(EU)
voltage levels; 1mW for maximum current and voltage levels), crest factor reaching 3 (half range CURRENT
reaching 6), and measurement of total harmonic distortion (at least 13th order power harmonic). For ITEM Range
large voltage/large current measurement applications of general power measurement, GPM-8213 MEASUREMENT CF=3 5mA,10mA,20mA,50mA,100mA,200mA,0.5A,1A,2A,
provides PT/CT rate function to collocate with external potential transformer or current transformer to 5A,10A,20A
meet the measurement requirements. CF=6 2.5mA,5mA,10mA,25mA,50mA,100mA,250mA,0.5A,
1A,2.5A,5A,10A
CREST FACTOR 3 or 6 (selectable)
With respect to data retrieval and storage, the standard RS-232C/USB interfaces (virtual COM)/LAN
can be utilized to edit and retrieve programs or the optional GPIB interface (installed by manufacturer) ACCURACY Effective Range 1% ~ 105% of range
DC ±(0.2% of reading+0.2% of range)
can be selected to meet users' automatic test system requirements. ±(0.1% of reading+0.1% of range)
45Hz≦f ≦66Hz
66Hz < f ≦1kHz ±(0.1% of reading+0.2% of range)
1kHz < f ≦6kHz ±3% of reading
SPECIFICATIONS Filter(ON) Add 0.3% of reading@45Hz ~ 66Hz
INPUT TEMPERATURE EFFECT 5-18゚C/28-40゚C Add ±0.03% of reading/゚C
ITEM Range RESIDUAL NOISE 0.5% of range
RATING VOLTAGE 600 Vrms POWER
RATING CURRENT 20 Arms ITEM Range
IMPEDANCE(50/60Hz) Voltage 2.4 MΩ MEASUREMENT Filter(ON) 30.000 Hz~9.9999 kHz
Current 5mA~200mA:500 mΩ Filter(OFF) 30.000 Hz~499.99 Hz
Current 0.5A~20A: 5 mΩ PARAMETER Voltage, Current GTL-209 Test Lead
MAXIMUM VOLTAGE 700 Vrms EFFECTIVE RANGE 10%~105% of voltage input
MAXIMUM CURRENT 25 Arms ACCURACY ±0.06% of reading
MAXIMUM COMMON 300 V
MODE VOLTAGE FREQUENCY
LOW PASS FILTER Cutoff frequency 500 Hz ITEM Range
PARAMETERS MEASUREMENT Filter(ON) 30.000 Hz~9.9999 kHz
Filter(OFF) 30.000 Hz~499.99 Hz
ITEM Symbol
GPM-8213

GPM-8213
MEASUREMENT Voltage PARAMETER Voltage, Current
Vdc, Vrms, V+pk, V-pk
Current Idc, Irms, I+pk, I-pk EFFECTIVE RANGE 10%~105% of voltage input
Power P, P+pk, P-pk, VA, Var ACCURACY ±0.06% of reading
Crest Factor CFV, CFI INTEGRATION
Power Factor PF
Frequency VHz, IHz ITEM Range
Angle Deg INTERGRATION Accuracy ±(voltage or current accuracy+0.1% of reading)
Total Harmonic THDV, THDI TIME Range 0 hour 00 min ~ 9999 hour 59 min
Distortion ±0.01%±1second
OTHER METERS

OTHER METERS
Accuracy
Integration Time, WP, WP+, WP-, q, q+, q-
DISPLAY
DISPLAY DIGITS 5 digits 4” TFT LCD
FREQUENCY BANDWIDTH DC, 45Hz~6kHz POWER CONSUMPTION
AVERAGE 1, 2, 4, 8, 16, 32, 64 Max. 25VA
PT RATE 1 ~ 9999.999 INTERFACE
CT RATE 1 ~ 9999.999 RS-232C, USB device, LAN
DISPLAY MODE Standard 8 measurement Item POWER SOURCE
Simple 4 measurement Item AC 100~240 V, 50-60Hz
VOLTAGE DIMENSION & WEIGHT
ITEM Range 270(W) x 110(H) x 350(D) mm, Aapprox. 2.9kg
RANGE CF=3 15V, 30V, 60V, 150V, 300V, 600V
CF=6 7.5V, 15V, 30V, 75V, 150V, 300V
CREST FACTOR 3 or 6 (selectable)
ACCURACY Effective Range 1% ~ 105% of range
DC ±(0.2% of reading+0.2% of range)
45Hz ≦ f ≦ 66Hz ±(0.1% of reading+0.1% of range)
66Hz < f ≦ 1kHz ±(0.1% of reading+0.2% of range)
1kHz < f ≦ 6kHz ±3% of reading
Filter(ON) Add 0.3% of reading@45Hz ~ 66Hz
TEMPERATURE EFFECT 5-18゚C / 28-40゚C Add ±0.03% of reading/゚C
RESIDUAL NOISE 0.5% of range

E59 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E60
Digital Power Meter

ORDERING INFORMATION
GPM-8213 with GPIB Digital Power Meter (RS-232C/USB device/LAN/Opt.01 GPIB) C. OPTIAML MEASUEMENT CAPABILITIES
GPM-8213 Digital Power Meter (RS-232C/USB device/LAN)
ACCESSORIES :
Safety Sheet x 1, Power Cord x 1, Test Lead GTL-209 x 2, CD x 1 (User manual/ USB driver)
OPTIONAL
Opt.01 GPIB card (factory installed)
OPTIONAL ACCESSORIES
GPM-001 Test Fixture
GTL-232 RS-232 Cable, 9-pin Female to 9-pin, null Modem for Computer
GTL-246 USB Cable, A-B type, approx. 1200mm
GTL-248 GPIB Cable, approx. 2000mm
GTL-251 GPIB-USB-HS+ (high Speed)
GRA-422 Rack Mount Kit
Low Current Range & High Resolution PT/CT Connection

For IEC 62301/EN 50564 standby power consumption test With respect to large power measurement, users can utilize terminal
requirement, GPM-8213 can fully meet the demand by its features, on the rear panel to conduct 600V/20A measurement. Users can
A. TWO DISPLAY MODES including measurement frequency bandwidth of DC~6kHz, also use external potential transformer/current transformer for
minimum current level of 5mA (resolution: 0.1uA), power measurement and collocate with PT/CT to set multiplying factor
measurement resolutions (1uW for minimum current and voltage (1~9999) to change readings to the original input voltage or current
levels; 1mW for maximum current and voltage levels). Beyond that, values without the trouble of additional calculation.
time resolution for integral measurement is one second.

D. VARIOUS STANDARD INTERFACES

Standard Mode (Setting & 8 Measurements) Simple Mode (4 Measurements)

GPM-8213 provides two display modes so as to maximize users' measurements) and related measurement setting parameters;
measurement effectiveness. Standard mode: simultaneously displays ideal for R&D, design, and engineering verification. Simple mode :
8 measurement parameters (2 major measurements + 6 secondary displays four measurement parameters; ideal for production tests.
GPM-8213

GPM-8213
B. VARIETY OF MEASUREMENT PARAMETERS

The various practical interfaces, RS-232/USB device/LAN, are remote control and measurement result collection. Also, GPIB is
MEASUREMENT ITEMS Symbols
OTHER METERS

OTHER METERS
Voltage Vrms, V+pk, V-pk, Vdc* equipped as standard making control convenient and flexible for available as optional.
Current Irms, I+pk, I-pk, Idc*
Power P, P+pk, P-pk, VA, VAR
Power Factor PF
Crest Factor CFV, CFI
Phase Angle DEG
Frequency VHz, IHz
Total Harmonic Distortion THDV, THDI
INTEGRATION WP, WP+, WP-, q, q+, q-
Note : “ * “ Vdc/Idc is selectable only when measurement mode DC is selected

Comparing with products of the same category, GPM-8213 provides measurement. GPM-8213 also features the integral measurement
more diverse measurement items and functions, including voltage, function for DUT's power or current time. Users can set a time
current, frequency, active power, apparent power, reactive power, period to execute the transient power integration and divide the
power factor, crest factor, and total harmonic distortion result by time to receive DUT's average power.

E61 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E62
A.C. Power Meter Logic Probe & Pulser

GPM-8212 is a bench-top power meter suitable for middle to high-end applications. Performance The GLP-1A logic pulsers can be used to perform in-circuit testing of TTL, CMOS, and many other logic devices at a maximum of 50MHz. GLP-1A is
and functionality are maintained at the highest level with a maximum 9999 CT/PT ratio, high enhanced with a logic probe function with a minimum detectable pulse width of 10 ns, providing enough sensitivity for most applications. A Short
immunity to external noise, and true RMS voltage/current/power. The user interface has been 10 sec pulse width assures that no damage will occur to circuits whilst testing. With a weight less than 50g, a non-slip grip and an external sync input
designed to simplify setup and operation. The large 0.56" display simultaneously shows all three all provide comfort and reliability for various troubleshooting tasks.
measurement units, Power/Voltage/Current, either as frequency (Hz) or power factor (PF).
The RS-232C or RS-485 PC interfaces allow data capture control and for automated test systems.
FEATURES
* Combining a Logic Probe and Pulser Combined into One
* Probe for Troubleshooting Digital Circuits
GPM-8212 * Operating Voltage : 4VDC~18VDC
* Maximum Input Signal Frequency: 50MHz
RS-485 * TTL : Logic "1" >3.0V + _0.25V
_ 0.25V, Logic"0" <0.75V +
* CMOS : Logic "1" >60%VCC _ +5%, Logic"0" <15% VCC +_ 5%
* Minimum Detectable Pulse Width 10nsec
FEATURES SPECIFICATIONS * Pulser : Sync Input Impedance 120k
VOLTAGE * Pulse Rate : Switchable 0.5/400Hz
* Simultaneous Display of W, A, V (PF or Hz) Range 5V, 10V, 20V, 40V, 80V, 160V, 320V, 640V total 8 ranges by auto-range * Pulse width : 10 sec
* True RMS V, A, W or manual.
* Dimensions & Weight : 18(W) x 210(H) x 18(D)mm, Approx. 50g
* Max. / Min. / Hold Function Measurement Type True RMS
Input Resistance _ 1MW
>
* High Immunity to External Noise
* CT Ratio (1 ~ 9999) Maximum Input Voltage 1000V(peak), 700V(rms)
GLP-1A (Logic Probe Pulser)
* PT Ratio (1 ~ 9999) PT Ratio Setting 1 ~ 9999
_5 C ) ( Sinewave)
Accuracy ( at 23 C + _0.1% of reading +
+ _0.1% of range ORDERING INFORMATION
CURRENT GLP-1A Logic Probe & Pulser
Range 160mA, 320mA, 640mA, 1.280A, 2.560A, 5.120A,10.24A, 20.48A total
8 ranges by auto-range or manual
Measurement Type True RMS
Input Resistance 0.01W
Maximum Input Current 30A(peak), 20A(rms)
CT Ratio Setting 1 ~ 9999
_ 5 C ) ( Sinewave)
Accuracy ( at 23 C+ _ 0.1% of reading +
+ _0.1% of range
WATT
Measurement Range 0.32mW ~ 13.10kW
Measurement Type True rms
_ 5 C ) ( Sinewave)
Accuracy ( at 23 C + _ 0.2% of reading +
+ _ 0.2% of range
POWER FACTOR
Range 0.001 ~ 1.000
Computation W/(V x A) = Power factor (PF)
Rear Panel _ 5 C ) ( Sinewave)
Accuracy ( at 23 C + _ 0.2% of reading +
+ _ 0.2% of range
FREQUENCY
GPM-8212

Measurement Range 40Hz ~ 400Hz


_5 C )
Accuracy( 23 C + _0.2% of reading +
+ _ 2 digits

GLP-1A
GENERAL
Display 4 digits 0.56" LED and 2 sets of 4 digits 0.4" LED
Minimum Input 2% of range
Response Time 2 cycles/sec
Overload Indicating " O.L"
OTHER METERS

OTHER METERS
INTERFACE
RS-232C or RS-485 Interface (decided before purchase)
POWER SOURCE
AC 100 ~ 230V, 50/60Hz ; Power Comsumption : Max. 28VA
DIMENSIONS & WEIGHT
251(W) x 91(H) x 291(D) mm, Approx. 1.6kg

ORDERING INFORMATION
GPM-8212 A.C. Power Meter
GPM-8212 (RS-232C) A.C. Power Meter with RS-232C Interface
GPM-8212 (RS-485) A.C. Power Meter with RS-485 Interface
ACCESSORIES :
User manual x 1 , Power cord x 1
OPTIONAL ACCESSORIES
GTL-232 RS-232C Cable, 9-pin Female to 9-pin, null Modem for Computer
FREE DOWNLOAD
PC Software Remote Control Software (RS-232C)

E63 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E64
ACCESSORIES ACCESSORIES

GTL-101 GTL-103 GTL-105A

GTL-107A GTL-110 GTL-117

GTL-205 GTL-207A GTL-209

GTL-210 GTL-108A GTL-308

GTL-128J GTL-128T GTL-128K

GDM-SC1 PT-100 GPM-001


OTHER METERS

OTHER METERS
GDM-01 GTL-250 GPM-001 (EU)

E65 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E66
ACCESSORIES ACCESSORIES

GHT-108 GHT-109 GHT-113 GTL-232 GTL-234 GTL-240

GHT-114 GHT-116B GHT-116R


GTL-246 GTL-247 GTL-248

GHT-117 GHT-118 GHT-205


GTL-251 GTL-253 LCR-12

GTL-115 GTL-116B GTL-116R


LCR-16 LCR-17 DC BIAS BOX (Optional)

GTL-215 GHT-119 GTC-001


470

430

820

GTL-132 GTL-235
OTHER METERS

OTHER METERS
GTC-002
330

430

GLC-02 GLC-01

820

E67 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E68
ACCESSORIES ACCESSORIES

GRA-404 Rack Mount Kit GRA-417 Rack Mount Kit FIXTURE MODEL CONNECTION DUT PACKAGE APPLICATION
For : GSP-830, LCR-8000G For : GPT-9900/9800/9600 Series, GCT-9040

177
177 LCR-05
Axial & radial lead Suitable for axial &
4 Wire
482.6
451.6 components radial lead type L, C, R
482.6
332.1

LCR-06B
GRA-422 Rack Mount Kit GRA-433 Rack Mount Kit
For : GDM-8261A/8255A/8342/8341/8351, LCR-6000 Series For : GPT-9904
4 Wire Suitable for low
Odd-shaped components
88 177
(Kelvin clip) R or high C

586
482.6 482.6
319.6

LCR-07
2 Wire Conventional component for in-circuit, Suitable for low
(Alligator clip) board-mounted components C or high R
GRA-419 EIA Rack Mount Kit GRA-419 JIS Rack Mount Kit
For : PCS-1000I For : PCS-1000I
99
99

LCR-08
477.6
477.6 333.3 333.3
4 Wire Suitable for SMD
SMD components
(SMD/chip tweezers) type L, C, R

LCR-09
4 Wire Suitable for SMD
SMD/chip components
(SMD/chip test fixture) Range:0603 to 1812

LCR-15
4 Wire Suitable for SMD
SMD/chip components
(SMD/chip test fixture) Range:0201 to 1812
OTHER METERS

OTHER METERS
E69 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. E70
NOTE

Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd.

Das könnte Ihnen auch gefallen